View
212
Download
0
Category
Preview:
DESCRIPTION
Details for Placement of Testing Loads
Citation preview
PLACEMENT OF TESTING LOADS FOR RAMP-1,RAMP-2 AND BRIDGE PANEL
RAMP 1
Single Footing loads:
For 1stin +ve X direction : 7.32 t
For 2nd in +ve X direction : 4.89 t
For 3rd in +ve X direction : 1.02 t
Total working load : 53 t
Total Testing load : 66.25 t (1.25 times of total working load)
5.05 m
RAMP 2
7.815 m
Single Footing loads:
For 1stin +ve X direction : 7.32 t
For 2nd in +ve X direction : 4.89 t
For 3rd in +ve X direction : 1.02 t
Total working load : 26.5 t
Total Testing load : 33.11 t (1.25 times of total working load)
STEEL BRIDGE
4.225 m
Single Footing loads:
For 1stin +ve X direction : 7.32 t
For 2nd in +ve X direction : 4.89 t
For 3rd in +ve X direction : 1.02 t
Total working load : 53 t
Total Testing load : 66.25 t (1.25 times of total working load)
RAMP-1 PADEYE (IWO RAMP & ELEVATED TRACK)
Zglobal
Xglobal
Yglobal
Xglobal
RAMP-2 PADEYE (IWO RAMP & ELEVATED TRACK)
Zglobal
Xglobal
Yglobal
Xglobal
RAMP-2 PADEYE (RAMP LIFTING)
Yglobal
Xglobal
Zglobal
Xglobal
A-FRAME - MAIN PADEYE FOR RAMP RETENTION
Yglobal
Xglobal
Zglobal
Xglobal