PSpeech Therapy
2
Speech Therapy
4
Book TR Room
5
Medical Store
6
Book TR Room
1
Unoccupied
Unoccupied
Unoccupied
Unoccupied
Unoccupied
Unoccupied
Unoccupied
Unoccupied
WC & Shower
8Staff WC
9
Hall
10
Womens Toilets
11
Mens Toilets
13
Wound Clinic
15
Medical Store
16
Wound Clinic
17
Bookable Room
18
Family Rm/Care Doc
19
Waiting Area
21Community Welfare
22Bookable Room
23
Room
24Child Health
25Sound Proof Room
26
Unoccupied
Unoccupied
Womens WC
12
Mens WC
14
Circuit1Panel 1
Coffer Light -Parabolic
Rectangular
Reception
20
Circuit9Panel 1
Coffer Light -Parabolic
Rectangular
Circuit11Panel 1
Coffer Light -Parabolic
Rectangular
Circuit10Panel 1
Coffer Light -Parabolic
Rectangular
Circuit12Panel 1
Coffer Light -Parabolic
Rectangular
Circuit<unnamed>Coffer Light -
ParabolicRectangular
Circuit6Panel 2
Coffer Light -Parabolic
Rectangular
Circuit5Panel 2
Coffer Light -Parabolic
Rectangular
Circuit4Panel 2
Coffer Light -Parabolic
Rectangular
Circuit3Panel 2
Coffer Light -Parabolic
Rectangular
Circuit2Panel 2
Coffer Light -Parabolic
Rectangular
Circuit1Panel 2
RecessedDirect-Indirect
Light -Asymmetrical
Circuit8Panel 1
Coffer Light -Parabolic
Rectangular
Circuit7Panel 1
RecessedDirect-Indirect
Light -Asymmetrical
Circuit6Panel 1
Coffer Light -Parabolic
Rectangular
Circuit5Panel 1
Coffer Light -Parabolic
Rectangular
Circuit4Panel 1
Coffer Light -Parabolic
Rectangular
Circuit3Panel 1
Coffer Light -Parabolic
Rectangular
Circuit11Panel 2
RecessedDirect-Indirect
Light -Asymmetrical
Circuit12Panel 2
RecessedDirect-Indirect
Light -Asymmetrical
Circuit8Panel 3
RecessedDirect-Indirect
Light -Asymmetrical
Circuit7Panel 3
RecessedDirect-Indirect
Light -Asymmetrical
Circuit3Panel 3
Ceiling Light - FlatRound
RecessedDirect-Indirect
Light -Asymmetrical
Circuit10Panel 3
Coffer Light -Parabolic
Rectangular
Circuit9Panel 3
Coffer Light -Parabolic
Rectangular
Circuit6Panel 3
Coffer Light -Parabolic
Rectangular
Circuit4Panel 3
Coffer Light -Parabolic
RectangularCircuit5Panel 3
Coffer Light -Parabolic
Rectangular
Circuit2Panel 1
RecessedDirect-Indirect
Light -Asymmetrical
Coffer Light -Parabolic
Rectangular
Scale
LECTURER
Drawn by
Date
Project number
Institute of Technology CarlowBSc. in Architectural Technology
Year 3 2015-2016
1 : 200
21/0
4/20
16 1
5:20
:34
Electrical Plan Layout
3
Calow Primary Health Care Centre
Issue Date
Xhevdet Haliti
Dan O Sullivan, Noel Dunne,Mark Duffy
A101
1 : 200
Ground floor - CeilingElectrical layout1
Notes:
Total Est. Demand Current: 6 ATotal Conn. Current: 9 A
Total Est. Demand: 4034 VAOther 0 VA 0.00% 0 VA Total Conn. Load: 6112 VALighting - Dwelling Unit 6112 VA 66.00% 4034 VALoad Classification Connected Load Demand Factor Estimated Demand Panel Totals
Total Amps: 7 A 10 A 11 A1504 VA 2208 VA 2400 VA
12 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.1 A11 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.1 A10 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.1 A9 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A8 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 4.2 A7 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 1.7 A6 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A5 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A4 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 1.4 A3 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A2 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 0.6 A1 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 1.4 A
CircuitNumber
CircuitDesignation Type of Wiring
Circuit Conductors (csa) Live,Neutral, CPC
MaxDisconnectionTime allowed
by BS7671
ProtectiveDeviceBS(EN)
PD Typenumber PD Rating
ShortCircuit
Capacity(kA)
RCDOperating
current (mA)
Maximum ZsPermitted by
BS 7671
A B C
Notes:
Enclosure: Type 1 MCB Rating:Mounting Type: Surface Mains Rating: 100 A
DB supplied from: No. of Phases: 3 Mains Type:Location of DB: Space 1 Voltage: 230/400 Wye A.I.C. Rating:
DB Schedule: Panel 1 Institute ofTechnology Carlow
Notes:
Total Est. Demand Current: 6 ATotal Conn. Current: 9 A
Total Est. Demand: 4245 VAOther 0 VA 0.00% 0 VA Total Conn. Load: 6432 VALighting - Dwelling Unit 6432 VA 66.00% 4245 VALoad Classification Connected Load Demand Factor Estimated Demand Panel Totals
Total Amps: 7 A 12 A 9 A1600 VA 2784 VA 2048 VA
12 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.2 A11 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 5.3 A10 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 1.1 A9 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 1.1 A8 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 0.6 A7 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 0.8 A6 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A5 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A4 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A3 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A2 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 3.5 A1 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.2 A
CircuitNumber
CircuitDesignation Type of Wiring
Circuit Conductors (csa) Live,Neutral, CPC
MaxDisconnectionTime allowed
by BS7671
ProtectiveDeviceBS(EN)
PD Typenumber PD Rating
ShortCircuit
Capacity(kA)
RCDOperating
current (mA)
Maximum ZsPermitted by
BS 7671
A B C
Notes:
Enclosure: Type 1 MCB Rating:Mounting Type: Surface Mains Rating: 100 A
DB supplied from: No. of Phases: 3 Mains Type:Location of DB: Space 1 Voltage: 230/400 Wye A.I.C. Rating:
DB Schedule: Panel 2 Institure ofTechnology Carlow
Symmetrical design, no required top or bottom mountingsSingle-piece deadfront – no filler plates neededSmaller, lighter panel than Spectra Series panelboardsEasy-to-install galvanized enclosures with removable endwallsReady-to-install hinged trim optionsBranch-bus direct connectionUp to 600A breaker mounted as a branch deviceDeeper (8"), wider (30") A-Series box to accommodate larger wire sizesDouble branched 150A (ED/SE) and 225A (QD) breakersVertically mounted main circuit breakers in 800ACaptive hardware on branch breakersStaggered, center-mounted, larger frame breakers (SG, SF) for easy installationBus-connected TVSS for maximum surge protectionNarrow design to minimize footprintEnclosure available in NEMA Type 1, Type 3R/12, Type 4/4X
An exceptional general lighting product that performs well in large spaces with high ceilings. Especially suitable for open office areas,public indoor spaces, libraries and airport waiting areas.
Moon Two - High frequency direct / indirect recessed luminaires are a range ofhigh efficiency luminaires designed to accommodate PL-L & T5 fluorescentlamps. These are suitable for general lighting in retail & commercial applications.
Typical electrical room layout with suspended ceilingand recessed coffer lighting shown.
Distrobution panel boards locate at Basement
Recommended