Electrical Lighing Layoout

Preview:

Citation preview

12

3

45

67

89

10

11

12

14

15

16

17

18

19

20

21

22

23

24

13

A

B

CD

E

F

H

I

J

K

L

M

PSpeech Therapy

2

Speech Therapy

4

Book TR Room

5

Medical Store

6

Book TR Room

1

Unoccupied

Unoccupied

Unoccupied

Unoccupied

Unoccupied

Unoccupied

Unoccupied

Unoccupied

WC & Shower

8Staff WC

9

Hall

10

Womens Toilets

11

Mens Toilets

13

Wound Clinic

15

Medical Store

16

Wound Clinic

17

Bookable Room

18

Family Rm/Care Doc

19

Waiting Area

21Community Welfare

22Bookable Room

23

Room

24Child Health

25Sound Proof Room

26

Unoccupied

Unoccupied

Womens WC

12

Mens WC

14

Circuit1Panel 1

Coffer Light -Parabolic

Rectangular

Reception

20

Circuit9Panel 1

Coffer Light -Parabolic

Rectangular

Circuit11Panel 1

Coffer Light -Parabolic

Rectangular

Circuit10Panel 1

Coffer Light -Parabolic

Rectangular

Circuit12Panel 1

Coffer Light -Parabolic

Rectangular

Circuit<unnamed>Coffer Light -

ParabolicRectangular

Circuit6Panel 2

Coffer Light -Parabolic

Rectangular

Circuit5Panel 2

Coffer Light -Parabolic

Rectangular

Circuit4Panel 2

Coffer Light -Parabolic

Rectangular

Circuit3Panel 2

Coffer Light -Parabolic

Rectangular

Circuit2Panel 2

Coffer Light -Parabolic

Rectangular

Circuit1Panel 2

RecessedDirect-Indirect

Light -Asymmetrical

Circuit8Panel 1

Coffer Light -Parabolic

Rectangular

Circuit7Panel 1

RecessedDirect-Indirect

Light -Asymmetrical

Circuit6Panel 1

Coffer Light -Parabolic

Rectangular

Circuit5Panel 1

Coffer Light -Parabolic

Rectangular

Circuit4Panel 1

Coffer Light -Parabolic

Rectangular

Circuit3Panel 1

Coffer Light -Parabolic

Rectangular

Circuit11Panel 2

RecessedDirect-Indirect

Light -Asymmetrical

Circuit12Panel 2

RecessedDirect-Indirect

Light -Asymmetrical

Circuit8Panel 3

RecessedDirect-Indirect

Light -Asymmetrical

Circuit7Panel 3

RecessedDirect-Indirect

Light -Asymmetrical

Circuit3Panel 3

Ceiling Light - FlatRound

RecessedDirect-Indirect

Light -Asymmetrical

Circuit10Panel 3

Coffer Light -Parabolic

Rectangular

Circuit9Panel 3

Coffer Light -Parabolic

Rectangular

Circuit6Panel 3

Coffer Light -Parabolic

Rectangular

Circuit4Panel 3

Coffer Light -Parabolic

RectangularCircuit5Panel 3

Coffer Light -Parabolic

Rectangular

Circuit2Panel 1

RecessedDirect-Indirect

Light -Asymmetrical

Coffer Light -Parabolic

Rectangular

Scale

LECTURER

Drawn by

Date

Project number

Institute of Technology CarlowBSc. in Architectural Technology

Year 3 2015-2016

1 : 200

21/0

4/20

16 1

5:20

:34

Electrical Plan Layout

3

Calow Primary Health Care Centre

Issue Date

Xhevdet Haliti

Dan O Sullivan, Noel Dunne,Mark Duffy

A101

1 : 200

Ground floor - CeilingElectrical layout1

Notes:

Total Est. Demand Current: 6 ATotal Conn. Current: 9 A

Total Est. Demand: 4034 VAOther 0 VA 0.00% 0 VA Total Conn. Load: 6112 VALighting - Dwelling Unit 6112 VA 66.00% 4034 VALoad Classification Connected Load Demand Factor Estimated Demand Panel Totals

Total Amps: 7 A 10 A 11 A1504 VA 2208 VA 2400 VA

12 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.1 A11 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.1 A10 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.1 A9 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A8 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 4.2 A7 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 1.7 A6 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A5 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A4 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 1.4 A3 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A2 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 0.6 A1 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 1.4 A

CircuitNumber

CircuitDesignation Type of Wiring

Circuit Conductors (csa) Live,Neutral, CPC

MaxDisconnectionTime allowed

by BS7671

ProtectiveDeviceBS(EN)

PD Typenumber PD Rating

ShortCircuit

Capacity(kA)

RCDOperating

current (mA)

Maximum ZsPermitted by

BS 7671

A B C

Notes:

Enclosure: Type 1 MCB Rating:Mounting Type: Surface Mains Rating: 100 A

DB supplied from: No. of Phases: 3 Mains Type:Location of DB: Space 1 Voltage: 230/400 Wye A.I.C. Rating:

DB Schedule: Panel 1 Institute ofTechnology Carlow

Notes:

Total Est. Demand Current: 6 ATotal Conn. Current: 9 A

Total Est. Demand: 4245 VAOther 0 VA 0.00% 0 VA Total Conn. Load: 6432 VALighting - Dwelling Unit 6432 VA 66.00% 4245 VALoad Classification Connected Load Demand Factor Estimated Demand Panel Totals

Total Amps: 7 A 12 A 9 A1600 VA 2784 VA 2048 VA

12 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.2 A11 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 5.3 A10 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 1.1 A9 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 1.1 A8 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 0.6 A7 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 0.8 A6 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A5 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A4 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A3 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.8 A2 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 3.5 A1 Lighting -... 6491B A (2) 1-#2.5mm, 1-#2.5mm, 1-#1.5mm 20 A 2.2 A

CircuitNumber

CircuitDesignation Type of Wiring

Circuit Conductors (csa) Live,Neutral, CPC

MaxDisconnectionTime allowed

by BS7671

ProtectiveDeviceBS(EN)

PD Typenumber PD Rating

ShortCircuit

Capacity(kA)

RCDOperating

current (mA)

Maximum ZsPermitted by

BS 7671

A B C

Notes:

Enclosure: Type 1 MCB Rating:Mounting Type: Surface Mains Rating: 100 A

DB supplied from: No. of Phases: 3 Mains Type:Location of DB: Space 1 Voltage: 230/400 Wye A.I.C. Rating:

DB Schedule: Panel 2 Institure ofTechnology Carlow

Symmetrical design, no required top or bottom mountingsSingle-piece deadfront – no filler plates neededSmaller, lighter panel than Spectra Series panelboardsEasy-to-install galvanized enclosures with removable endwallsReady-to-install hinged trim optionsBranch-bus direct connectionUp to 600A breaker mounted as a branch deviceDeeper (8"), wider (30") A-Series box to accommodate larger wire sizesDouble branched 150A (ED/SE) and 225A (QD) breakersVertically mounted main circuit breakers in 800ACaptive hardware on branch breakersStaggered, center-mounted, larger frame breakers (SG, SF) for easy installationBus-connected TVSS for maximum surge protectionNarrow design to minimize footprintEnclosure available in NEMA Type 1, Type 3R/12, Type 4/4X

An exceptional general lighting product that performs well in large spaces with high ceilings. Especially suitable for open office areas,public indoor spaces, libraries and airport waiting areas.

Moon Two - High frequency direct / indirect recessed luminaires are a range ofhigh efficiency luminaires designed to accommodate PL-L & T5 fluorescentlamps. These are suitable for general lighting in retail & commercial applications.

Typical electrical room layout with suspended ceilingand recessed coffer lighting shown.

Distrobution panel boards locate at Basement

Recommended