GeoCenter LP Marine Processing SeisUP ®. University of Texas / Dallas Offshore Oregon Processed By:...

Preview:

Citation preview

GeoCenter LP

Marine ProcessingSeisUP ®

SeisUP ®

University of Texas / Dallas

Offshore Oregon

Processed By: GeoCenter

for Training Session utilizing

SeisUP ®

Table of Contents

Slides Subject

4 Processing Flow

5-6 Processing Flow # 1 & 2

7 Raw Record Display

8-9 Near Trace Displays

10-11 Brute Velocity Analysis

12 QC Stack

13 Gain Analysis

14-15 A/C & Decon QC

16-17 Decon Velocity Analysis

18 Decon Stack

19 Radon QC

20-21 Radon Velocity Analysis

Slides Subject

22-23 Radon Stacks

24-25 Radon DMO Velocity Analysis

26 DMO Stack

27 KTMIG Stack

28 DMO Angle Gather QC

29-31 AVO Cross Plots

32-33 Angle Stacks

34-36 Aperture Model QC

37 SMIG Stack

38 Closing

SeisUP ®

SeisUP ®

Processing Flow

Reformat to GCI format

Geometry

Near trace extraction

Spherical divergence correction

Surface consistent gain correction

Spike edit

Deconvolution

Velocity analysis

Stack

Radon

Dip moveout correction

Velocity analysis

Stack

KTMIG

AVO Processing

Angle Stack QC

Angle Stacks (15 & 30 degrees)

AVO Crossplots

AVO (intercept & gradient) Stack

Additional QC

Radon Test

Apperture Modeling Test

SeisUP ®

SeisUP ®

Processing Flow (1)

Page 5 / 38

University of Texas / Dallas

Offshore Oregon

Processing Flow (1)

SeisUP ®

Processing Flow (2)

Page 6 / 38

University of Texas / Dallas

Offshore Oregon

Processing Flow (2)

SeisUP ®

Raw Record Display

Page 7 / 38

Raw Record Display

SeisUP ®

Near Trace (all shots)

Page 8 / 38

Near offset display

All Shots

SeisUP ®

Near Trace (every 3rd Shot)Near offset display

Edit: every 3 rd shot

Page 9 / 38

SeisUP ®

Brute Velocity Analysis

Page 10 / 38

Brute Velocity Analysis

SeisUP ®

Brute Velocity Analysis

Page 11 / 38

Brute Velocity Analysis

SeisUP ®

Brute Stack Alternate Trace Display

(zoomed zone of interest)

Page 12 / 38

SPER + NMO + STACK + AGC

SeisUP ®

Gain Analysis

Page 13 / 38

Surface Consistent Amplitude Analysis

SGN1 +SGN2

Before After

SeisUP ®

Auto Correlation Analysis

Page 14 / 38

Auto Correlation Analysis

SeisUP ®

Decon A/C AnalysisSpiking Deconvolution

Operator= 160 msec

Auto Correlation Analysis

Page 15 / 38

SeisUP ®

Decon Velocity Analysis

Page 16 / 38

Decon Velocity Analysis

SeisUP ®

Decon Velocity Analysis

Decon Velocity Analysis

Page 17 / 38

SeisUP ®

Decon Stack

Page 18 / 38

SPER +SGN3 + DECON + NMO + STACK + AGC

Alternate Trace Display

(zoomed zone of interest)

SeisUP ®

Radon QC

Page 19 / 38

Before

Radon QC

After Removed

SeisUP ®

Radon Velocity Analysis

Decon + Radon Velocity Analysis

Page 20 / 38

SeisUP ®

Radon Velocity Analysis

Decon + Radon Velocity Analysis

Page 21 / 38

SeisUP ®

Radon Stack

SPER +SGN3 + DECON + RADON (TP)+NMO + STACK + AGC

Page 22 / 38

Alternate Trace Display

(zoomed zone of interest)

SeisUP ®

Radon Stack

Page 23 / 38

SPER +SGN3 + DECON + RADON + NMO + STACK + AGC

Alternate Trace Display

(zoomed zone of interest)

SeisUP ®

DMO Velocity Analysis

Decon + Radon + DMO Velocity Analysis

Page 24 / 38

SeisUP ®

DMO Velocity Analysis

Page 25 / 38

Decon + Radon + DMO Velocity Analysis

SeisUP ®

DMO Stack

Page 26 / 38

Decon + Radon + DMO + Filter+ AGC

SeisUP ®

KTMIG Stack

Decon + Radon + DMO +KTMIG + Filter+ AGC

Page 27 / 38

SeisUP ®

Angle Gather QC

DMO Angle Gather QC (0-50/10 = 5 degrees)

Page 28 / 38

SeisUP ®

AVO Cross Stack

AVO Cross – P-wave Intercept and Gradient

Page 29 / 38

SeisUP ®

AVO Cross Plot

Page 30 / 38

SeisUP ®

AVO Cross Plot

Page 31 / 38

SeisUP ®

Angle Stack (0-15 degree)

Angle Stack 0-15 degrees

Page 32 / 38

SeisUP ®

Angle Stack (0-30 degree)

Angle Stack 15 - 30 degrees

Page 33 / 38

SeisUP ®

Aperture Model QC

Aperture Model QC (one sided)

Design desired aperture =

Number of traces x TR. Interval x 2 (for full aperture)

Page 34 / 38

SeisUP ®

Designed Aperture Model QC

Aperture Model QC (one sided)

Aperture designed by controlling distance and time

varying dip.

Page 35 /38

SeisUP ®

Designed Aperture Model QC

Aperture Model QC (one sided)

Aperture designed by time varying dip only.

Page 36 / 38

SeisUP ®

SMIG

Decon + Radon + DMO + SMIG + Filter+ AGC

Page 37 / 38

SeisUP ®

GeoCenter has made every effort to ensure the accuracy of the information herein. However, appropriate information sources should be consulted, especially for new or unfamiliar processing procedures. It is the responsibility of the processing geophysicist to evaluate and

conclude his/her own opinion to the context of the material presented.

It is forbidden to reproduce or to transmit in any form or by any means, electronic or mechanical , including photocopying any portion of this presentation without written permission from the University of

Texas/Dallas and GeoCenter.

SeisUP ®

SeisUP ®

GeoCenter LP4805 WestWay Park Blvd.

Houston, TX 77041281.443.8150

Recommended