View
217
Download
0
Category
Preview:
Citation preview
8/7/2019 HE Notes 1
1/25
Heat Transfer Operations
How to heat/cool fluids (gas/liquid) in a plant?
What are HT equipment? How do they look?
How many types? Advantages & disadvantages?
How do they operate? How much heat transfer?
How to select & design (size or specify) them?
Useful referencesProcess heat transfer, McGraw Hill, 1964, by DQ Kern
Perrys handbook, McGraw Hill.A guide to ChE process design & economics, John Wiley,
1984, by GD Ulrich
Process design principles, John Wiley, 1999 by WD Seider,JD Seader, DR Lewin
8/7/2019 HE Notes 1
2/25
Select Process Utilities for Various Ts
Media external to process vs. process fluid Refrigerants: 60 - 5 C
Freon, ammonia, methane, ethane, ethylene, CO2, etc.How do we use them? Recall refrigeration cycle?
Brine or chilled water: 5 - 10 C (e.g. NaCl solution)
Any liquid cooled by a refrigerant and used as a cooling agent
Cooling water (CW) & air: 20 - 40 CNatural water (sea, pond, river) at 20-30 C, discharge 45 C
Closed-circuit CW at 40 C, discharge at 50-60 C is air-cooled
Cooling tower CW at 30 C, discharge 45 C max (Why?)
Process steam: 100 - 300 CHigh P (HP): 45 bar, 400 C (Superheated)
Medium-High P (MHP): 33 bar, 239 C (Saturated)
8/7/2019 HE Notes 1
3/25
Select Process Utilities for Various Ts
Medium P (MP): 17 bar, 204 C (Saturated)
Medium-Low P (MLP): 9 bar, 175 C (Saturated)
Low P (LP): 4.5 bar, 148 C (Saturated) HT oils or heavy oils: 250 - 400 CDowtherm A, Dowtherm E, mineral oil, silicon oil, etc.
Stable, noncorrosive, low vapor pressure fluids
Liquid metals, molten salts (Why?): 250 - 600 CSodium, potassium, mercury, alkali nitrates, etc.
No appreciable vapor pressure
Boiler feed water (BFW) or demineralized water
(DMW): 100 - 300 C30-40 ppm solids for BFW, 320 ppm solids for cooling tower
8/7/2019 HE Notes 1
4/25
Three Types of HT Equipment
Direct fired equipment burn fuel, generate hot flue gas &use the gas to heat
Coal, heavy oil, natural gas, solid waste, etc.Boiler produces steam at different levels from BFW
Furnace heats or vaporizes a process fluid to high T
Indirect fired equipment burn fuel, use hot flue gas toheat a thermal fluid, which in turn heats the process fluid
Dowtherm, mineral oil, liquid metals, etc.
Unfired equipment do not burn fuel, but heat or cool viaa process fluid or utility
With phase change: Change sensible & latent heat contentsWithout phase change: Change sensible heat content only
8/7/2019 HE Notes 1
5/25
Two Types of Unfired HT Equipment
Unfired equipment without phase changeCooler cools by indirect HT using CW or air
Cooling tower cools hot CW by direct air contactChiller cools by brine or refrigerant
Heater heats by a process utility (steam / oil)
Exchanger exchanges heat between two process fluids
Unfired equipment with phase changeCondenser liquefies a vapor (Total vs. partial)
Vaporizer vaporizes a liquid other than water (e.g. reboiler)
Evaporator concentrates a solution by evaporating water
Waste heat boiler (WHB) produces steam by evaporatingBFW
8/7/2019 HE Notes 1
6/25
Specification of HT Equipment
Total HT rate or heat duty Q (J/s or Btu/h)
Total HT area A (m2 or ft2)
HT media and/or process fluidsOperating conditions (inlet/outlet T & P)
Equipment type, size, material, mechanical detailsTravel paths of hot and cold fluids Sufficient for preliminary cost estimation
Rating (vs. Design): Given a HT equipment, analyze itsperformance for a given application
Identify outlet fluid temperatures & pressures
Simulation vs. design
8/7/2019 HE Notes 1
7/25
Steps in Designing a HT Equipment
Primary goal: Find HT area A across which heattransfers in the equipment
Step 1: Total heat duty Q (W or Btu/h)Steady state rate of total heat transfer between streams
Step 2: Select equipment type, assign fluid paths
Step 3: Overall temperature driving force T (K or F)Average T between streams, which varies with fluid contact
pattern and temperature profiles Step 4: Overall HT coefficient U (W/m2-K)Coefficient measuring the rate of heat transfer as a function of
fluid flows and properties
Step 5: Compute HT area A (m2) = Q / [U T]
8/7/2019 HE Notes 1
8/25
Step 1: Compute Heat Duty Q
FIX inlet and outlet temperatures of streamsProblem specifies or use thumb rules (CW 30-45 C, 40-60 C)
Select appropriate for economic design
Overall energy balance (No heat loss or gain)
HT
Equipment
Hot Fluid
Cold Fluid
Tha ThbTcb Tca
General: Q = mh(Hha Hhb) = mc(Hcb Hca)No phase change: Q = mhcph(Tha Thb) = mccpc(Tcb Tca)
Step 2: Select equipment type: Four main types of HE
8/7/2019 HE Notes 1
9/25
Double Pipe Exchanger (DPE)
Simplest, but large & cumbersome heat exchangerTwo long, concentric pipes; one (the inner pipe) inside the
other (the outer pipe)One fluid flows in the inner pipe, the other in the outer
Heat transfers across the wall of inner pipe.
Counter (countercurrent): Fluids flow in opposite directionsParallel (cocurrent): Fluids flow in the same direction
Heat transfer A < 10 m2, P < 1000 bar, T < 150 C
Outside Fluid
Outer PipeAnnulus
Inner Pipe
Inside Fluid
Outside Fluid HT
8/7/2019 HE Notes 1
10/25
Double Pipe Exchanger (DPE)
8/7/2019 HE Notes 1
11/25
Shell & Tube (S&T) Heat Exchanger
The most common, very compact heat exchangerOuter pipe of DPE becomes shell and a bundle of small tubes
replaces the inner pipeDouble pipe exchanger is a special case of S&T HE
One fluid flows in the tubes, the other in the shell
Heat transfers across tube wallsA < 1000 m2, P < 140 bar, T < 350 C
Larger area, lower cost per unit area, but lower pressure
Wide variety of types, configurations & sizes
8/7/2019 HE Notes 1
12/25
Shell & Tube Exchanger (S&T)
8/7/2019 HE Notes 1
13/25
8/7/2019 HE Notes 1
14/25
8/7/2019 HE Notes 1
15/25
Air Cooled Exchanger
8/7/2019 HE Notes 1
16/25
Stpes 3 & 4: Overall T & U
Most HEs use indirect HT across metal (tube) wall
Small tube element of length x with rate of HT = dq
Cold fluid inside with bulk T = Tc, hot fluid outside with bulkT = Th
How many resistances for heat transfer? What are they?
Metal Tube (ID = Di & OD = Do)
Di Dox
dq
0
( )
( )
( ) /
i i wi c
o o h wo
w w wo wi w
i i
o
dq h dA T T
dq h dA T T
dq k dA T T t
dA D x
dA D x
=
=
=
=
=
8/7/2019 HE Notes 1
17/25
Film Heat Transfer Coefficient h
Measures conductance to heat transfer: Higher the betterEstimated from empirical correlations obtained from
experimental measurements Rough ranges of h (W/m2-K). What does h depend on?Steam condensation: 6,000-100,000
Boiling water: 1,700-50,000
Water (heating/cooling): 300-20,000
Condensing organic vapors: 1,000-2000
Oils (heating/cooling): 50-1,500
Steam (superheating): 30-100
Air (heating/cooling): 1-50
How can we avoid dealing with wall temperatures?
h varies
from point
to point
along
flow!
8/7/2019 HE Notes 1
18/25
Overall Heat Transfer Coefficient U
Define local overall HT coefficient (U) to relate localHT rate dq to local bulk temperatures of fluids
Defined based on outside tube area
1 1 1( ) & o w o
o h c
o i i w w
dA t dAdq UdA T T
U h h dA k dA
= = + +
Metal resistance often neglected (How to justify?)1 1 1
o
o i i
D
U h h D
= +
Limiting or controlling coefficient? (Smaller of hi & ho)hi
8/7/2019 HE Notes 1
19/25
Resistance from Fouling is Important
Fluid velocity at metal wall is zeroSome fluid spends a long time at the wall
Dirt, scale, corrosion, etc. deposit on tube wallDeposit grows thicker with time; becomes an additional and
significant resistance with low k
Resistance much greater than metal wall, not negligible This is called dirt or scale or fouling factor (Rd)Depends on nature of fluid (content, fouling, clean, corrosive,
side reactions), fluid temperature, and time between clean-ups
or maintenance etc.
Normally based on yearly clean-up or maintenance, Rd =
0.001-0.006 Btu/ft2-F-h/Btu (resistance) for most industrialliquids.
8/7/2019 HE Notes 1
20/25
Must Account for Fouling Resistances
Ensure satisfactory service over time by using UD =dirty U or design U that includes fouling resistances
1 1 odi do
D C i
DR RU U D
= + +
Local rate of HT: dq(x) = UD(x) [Th(x) Tc(x)] dAoUD, Th, Tc vary with position dAo, as fluids heat/coolHow to get Q or total rate of HT for the equipment?
0 0
( )
Q A
D h c oQ dq U T T dA= = dA = D
odx
dq
Do
dx
Tc+dTcTcTube:
Tedious, trial & error, integration: How to simplify?
8/7/2019 HE Notes 1
21/25
Overall Temperature Difference T
Simplify the general integral HE design equation as:
0
( )[ ( ) ( )]
A
D h c o
Q U x T x T x dA UA T = =
Assume U constant along the length of tube
Fluid enthalpy H vs. T linear for both fluids (constant heatcapacities and no phase change)
Negligible heat exchange with the ambient
Steady state flow (parallel or counter)No heat generation/work input in the unit (e.g. reaction)
Do the simplification for counter flow DPE
8/7/2019 HE Notes 1
22/25
LMTD for a DPE Cooler
Process fluid 120 C to 40 C, let CW 30 C to 45 C
Counter flow: T1 = 10 C, T2 = 75 C
LMTD = (1075) / ln(10/75) = 65/ln 7.5 = 32.3 C
Parallel flow: T1 = 90 C, T2 = 5 C
LMTD = 29.4 C? Is this OK?
Double Pipe Exchanger40 C120 C
30 C45 C
Double Pipe Exchanger 40 C120 C
45 C30 C
8/7/2019 HE Notes 1
23/25
Impact of Parallel Flow
What can you do to the parallel flow cooler?Process fluid cannot cool to 40 C or CW cannot leave at 45 C
What are the corresponding min and max Ts? What if CW leaves at 35 C & process fluid at 40 C?LMTD = 29.4 C More HT area vs. counter flow, why?
More CW required for the same Q
What if CW leaves at 45 C & process fluid at 50 C?
Less heat recovered from the process fluid vs. counter flowLMTD = 29.4 C, will HT area go up or down? How can you
estimate?
8/7/2019 HE Notes 1
24/25
Range, Approach & Cross
Range: T for a fluidHot fluid: ThaThb & Cold fluid: TcbTca
Approach: T between fluids at an endCounter flow: T1 = ThaTcb & T2 = ThbTca
Parallel flow: T1 = ThaTca & T2 = ThbTcb
Minimum approach = min[T1, T2]
Cross: T by which cold fluid heats above the exittemperature of hot fluid or TcbThb
Heat
Exchanger
Hot Fluid
Cold Fluid
Tha ThbTcb Tca
8/7/2019 HE Notes 1
25/25
What if We Decrease Approach?
LMTD & area for a given Q? Heat recovery Q?
What if min approach 0? How much min approach is economical?
5-10 K for liquids or systems with high HT coefficients50 K for gases or systems with low HT coefficients, why?
2-5 K for refrigeration systems.
Select inlet-outlet temperatures as per the above thumb rules
Heat
Exchanger
Hot Fluid
Cold Fluid
Tha ThbTcb Tca
Recommended