IESNA LM79 - 2008 Test Report
Photometric testing and evaluation in accordance with LM79-2008
Laboratory : Ilmenau University of TechnologyGroup of Lighting EngineeringProf.-Schmidt-Str. 2698693 Ilmenau / Germany
Report prepared for: R. STAHL Schaltgeräte GmbHNordstraße 1099427 Weimar / Germany
Report number: LM7920151016-F / 02
Testing performed by : ILEXA GbRWerner-von-Siemens-Straße 4a98693 Ilmenau / Germany
Tel.: (+49) 3677 / 466 33 0Fax: (+49) 3677 / 466 33 14Internet: www.ilexa.de
Sample tested: 6125/...4-21..-...1-...
Manufacturer: R. STAHL Schaltgeräte GmbH
Table of contents
1. Description of test sample................................................................................................31.1. General Informationen.....................................................................................................31.2. Manufacturer specifications..............................................................................................31.3. Pictures............................................................................................................................32. Scope of testing...............................................................................................................43. Equipment........................................................................................................................44. Additional information.......................................................................................................45. Test Results.....................................................................................................................56. Results goniophotometer.................................................................................................66.1. Illuminance plots..............................................................................................................66.2. Candela plots...................................................................................................................77. Results spectroradiometer...............................................................................................97.1. Relative spectral distribution............................................................................................97.2. Chromaticity diagram.....................................................................................................10
ILEXA GbR • Werner-von-Siemens-Str. 4a • 98693 Ilmenau / Germany • Tel.: (+49) 3677 / 466 33-0 • Fax: (+49) 3677 / 466 33-14
Date: 30.10.2015 IESNA LM79 - 2008 Test Report- Nr. LM7920151016-F / 02 Page 2 of 10
General Information
This report may not be reproduced except in full without permission of ILEXA GbR.
This technical report may only be quoted in full. Any use for advertising purposes must begranted in writing. This report is the result of a single examination of the object in questionand is not generally applicable evaluation of the quality of other products in regularproduction.
________________________________
Wladimir JordanowILEXA GbR president
1. Description of test sample
1.1. General Informationen
Sample received: 12.10.2015
Manufacturer: R. STAHL Schaltgeräte GmbHNordstraße 1099427 Weimar / Germany
Model number: 6125/...4-21..-...1-...
Model type: Luminaire
Length / Width / Height: 600 mm / 400 mm / 180 mm
1.2. Manufacturer specifications
Voltage (V): 230 AC
Frequency (Hz): 50
1.3. Pictures
Figure 1: Luminaire housing as measured Figure 2: Luminaire LED panel with optics
ILEXA GbR • Werner-von-Siemens-Str. 4a • 98693 Ilmenau / Germany • Tel.: (+49) 3677 / 466 33-0 • Fax: (+49) 3677 / 466 33-14
Date: 30.10.2015 IESNA LM79 - 2008 Test Report- Nr. LM7920151016-F / 02 Page 3 of 10
2. Scope of testing
‐Photometric and electrical testing in accordance with IESNA LM 79 2008 IES (ApprovedMethod: Electrical and Photometric Measurements of Solid-State Lighting Products).All measurements are made using the goniophotometer / spectroradiometer test method.
The spectral values are measured at a given direction with vertikal angle theta= 0°.
Date of test: 14.10.2015
Report and test prepared by: Kranhold / ILEXA GbR
3. Equipment
‐Testing is performed in accordance with the procedures outlined in IESNA LM79 2008.The sample is evaluated for photometric and electrical characteristics using a goniophotometer,located in an temperature - controlled, draft free photometric laboratory.
Item Manufacturer Model Calibration due
Goniophotometer TechnoTeam RiGo801 yearly
Spectroradiometer Jeti specbos 1211 yearly
Power Supply Statron AG BE2/01H-IP-R20-B N/A
Digital Power Meter Yokogawa WT110 N/A
Table 1: Test Instrumentation
4. Additional information
(none)
ILEXA GbR • Werner-von-Siemens-Str. 4a • 98693 Ilmenau / Germany • Tel.: (+49) 3677 / 466 33-0 • Fax: (+49) 3677 / 466 33-14
Date: 30.10.2015 IESNA LM79 - 2008 Test Report- Nr. LM7920151016-F / 02 Page 4 of 10
5. Test Results
The results were obtained after stabilization of the sample in accordance with the requirementsset forth in section 5.0 of IES LM79-2008.
Goniophotometer Spectroradiometer
Total luminous flux (lm) 11763 -
Luminous efficacy (lm/W) 98 -
Correlated color temperature (CCT) - 5629
Color rendering index (CRI - Ra) - 73,34
Chromaticity (x / y) - 0,3295 / 0,3482
Table 2: Photometric results
Input power (W) 119,5
Input voltage (VAC) 230,1
Input current (A) 0,5319
Input frequency (Hz) 50
Table 3: Electrical results
Orientation (burning position) during test horizontal
Prior operation time (minutes) 91
Stabilization time (minutes) 30
Total operating time (minutes) 157
Ambient temperature (°C) 24,0
Table 4: Additional Parameters
ILEXA GbR • Werner-von-Siemens-Str. 4a • 98693 Ilmenau / Germany • Tel.: (+49) 3677 / 466 33-0 • Fax: (+49) 3677 / 466 33-14
Date: 30.10.2015 IESNA LM79 - 2008 Test Report- Nr. LM7920151016-F / 02 Page 5 of 10
6. Results goniophotometer
6.1. Illuminance plots
Figure 3: Isolux diagram (mounting height 3m)
ILEXA GbR • Werner-von-Siemens-Str. 4a • 98693 Ilmenau / Germany • Tel.: (+49) 3677 / 466 33-0 • Fax: (+49) 3677 / 466 33-14
Date: 30.10.2015 IESNA LM79 - 2008 Test Report- Nr. LM7920151016-F / 02 Page 6 of 10
0 2-2 4 m-4 m
0 0
2 m 2 m
-2 -2
16
1616
16 32
32
32
32
64 64
64
64
64
64
64
125
125
125
125
125
125
250
250
250
250
ti lt angle :
swivel angle:
0,0
0,0
°
°
mounting height:
orientation :
3,0
0,0
m
°
light loss factor : 1,0
6.2. Candela plots
Figure 4: 3D - luminous intensity distribution ( point of view 1 )
Figure 5: 3D - luminous intensity distribution ( point of view 2 )
ILEXA GbR • Werner-von-Siemens-Str. 4a • 98693 Ilmenau / Germany • Tel.: (+49) 3677 / 466 33-0 • Fax: (+49) 3677 / 466 33-14
Date: 30.10.2015 IESNA LM79 - 2008 Test Report- Nr. LM7920151016-F / 02 Page 7 of 10
Figure 6: Polar candela distribution
Figure 7: Cartesian candela distribution
ILEXA GbR • Werner-von-Siemens-Str. 4a • 98693 Ilmenau / Germany • Tel.: (+49) 3677 / 466 33-0 • Fax: (+49) 3677 / 466 33-14
Date: 30.10.2015 IESNA LM79 - 2008 Test Report- Nr. LM7920151016-F / 02 Page 8 of 10
C0,0-C180,0 C90,0-C270,0
90°90°
75°
60°
45°
30° 15° 0° 15° 30°
45°
60°
75°
2000
3000
4000
cd
0
1000
2000
3000
4000
5000
0°45° 45°90° 90°135° 135°180° 180°
C0,0 C90,0
I (cd)
beam angle
7. Results spectroradiometer
7.1. Relative spectral distribution
Figure 8: Relative spectral distribution
ILEXA GbR • Werner-von-Siemens-Str. 4a • 98693 Ilmenau / Germany • Tel.: (+49) 3677 / 466 33-0 • Fax: (+49) 3677 / 466 33-14
Date: 30.10.2015 IESNA LM79 - 2008 Test Report- Nr. LM7920151016-F / 02 Page 9 of 10
0 2 4 6 8 10 12
0
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
1
Wavelength [nm]
Re
lative
sp
ectr
al d
istr
ibu
tio
n
350 400 450 500 550 600 650 700 750 800 850 900 950 1000
0,0
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
1,0
Wavelength [nm]
Re
lative
sp
ectr
al d
istr
ibu
tio
n
7.2. Chromaticity diagram
Figure 9: Chromaticity diagram
Tristimulus Value
x 0,3295
y 0,3482
The location on the diagram of the tristimulus coordinates are indicated by the blue axes on cross.
ILEXA GbR • Werner-von-Siemens-Str. 4a • 98693 Ilmenau / Germany • Tel.: (+49) 3677 / 466 33-0 • Fax: (+49) 3677 / 466 33-14
Date: 30.10.2015 IESNA LM79 - 2008 Test Report- Nr. LM7920151016-F / 02 Page 10 of 10