View
214
Download
1
Category
Tags:
Preview:
Citation preview
JPR 18-2B
B Once the lead saw (firefighter on the right) has established the ID cut and the primary head cut, he
will begin the parallel cuts four inches inside the purlin. The secondary saw (firefighter on the left) operates in
unison to establish the head cut, followed by the parallel cuts.
JPR 18-2C
C Here both saws work in unison back toward their means of egress, extending the parallel cuts and rolling the first rafter with which they come in
contact.
JPR 18-2D
D Another view of the ventilation team making the parallel cuts approximately four inches inside the
purlin, working back toward their means of egress.
JPR 18-2E
E Once the ventilation team has made contact with the second rafter or support member, they stop cutting any further and establish the bottom cut. In this photo, the ventilation team has come in contact with the second support member and are stopping the parallel cuts.
JPR 18-2F
F This photo shows the fourth and final cuts in the sequence. The bottom cut is made approximately four inches on the top side of the second support
member.
JPR 18-2G
G This photo shows a successful louver-in-lieu operation, in which a tactically offensive heat hole was
established in a commercial occupancy heavily involved with fire. The louver in lieu is approximately 32 x 8 feet
and quickly increased the visibility and tenability for interior companies.