View
5
Download
0
Category
Preview:
Citation preview
Price List USF05-1
55 Guardsman RoadThornhill, OntarioCanada, L3T 6L2
Tel: 905-889-7890Fax: 905-889-8553info@chemline.comwww.chemline.com
Effective March 1, 2005Supersedes Price List F04-2All Prices are in U.S. DollarsSubject to change without notice
PDF Published February 8, 2006
Page
Flow Sensors 2-4
Instruments 5
Instrument Mounting Kits 5
Flow Switches 6
Blind Transmitters 7
Packages
Monitor/Transmitter 8-13
Battery Powered Flow Monitor 14-15
Batch Controller 16-17
ULF Monitor/Transmitter 18
ULF Battery Powered Flow Monitor 19
ULF Batch Controller 19
Installation Fittings 20-21
Plugs 21
Electromagnetic Flow Transmitter 22
Flow Units Conversion Chart 22
Flow Meter Selection Questionnaire 23
Paddle Wheel Flow Metersand Instruments
Established in 1968Your Pipeline To Quality Valves,Piping, Flow Meters and Controls
02/06 ©Chemline Plastics Limited 2006Chemline is a registered trade mark of Chemline Plastics Limited
Digiflow® is a registered trade mark of Chemline Flow Control Limited
Orders over US$500.00 Net– No additional charge for shipping*
anywhere in the continental U.S.A.
Orders $200.00 to $500.00 Net– Add $40.00 to order for shipping*.
Orders under $200.00 Net– All shipping* charges are collect.
* Shipping charges include U.S. Duty, Brokerage, Ground Freight andInsurance.
Chemline accepts:
Flow Sensors
2 Price List USF05-1 Consult Chemline Plastics for availability.Subject to change without notice.
Type F3.01.H – for Direct Mounting to Instruments
Type F3.00.H – for Connection to Panel or Wall Mount Instruments
Flow SensorsInstallation fittings are required for these paddle wheel typesensors. See pages 20 and 21 for fittings and to determine sensorlength required (L0 or L1).
Hall Effect SensorsHall Effect Flow Sensors require a supply voltage between 5 and24 VDC. A square wave output signal is generated with frequencyproportional to flow velocity. The signal is normally fed to aF9.00, F9.01, F9.02, F9.03 or F9.50 Instrument which will supplypower to the sensor. See page 5.
F3.00 IP65
IP68 – NEMA 6, 6PSupplied with 6" long
cable, 22 AWG,3 conductors
L0
F3.01.H.01334.00
F3.01.H.02334.00
CPVCElectrical Class
Sensor Length
Body
0-Ring
EPDM
Viton®
L1
F3.01.H.03351.00
F3.01.H.04351.00
L0
F3.01.H.05453.00
F3.01.H.06453.00
PVDF
L1
F3.01.H.07637.00
F3.01.H.08637.00
IP68 – NEMA 6, 6PSupplied with 8 m(26’) long cable, 22AWG, 3 conductors
L0
F3.00.H.01414.00
F3.00.H.02414.00
CPVCElectrical Class
EPDM
Viton®
IP65 – NEMA 4, 4XSupplied with
4-pole cable plug(cable is not supplied)
F3.00.H.13414.00
F3.00.H.14414.00
L1
F3.00.H.03434.00
F3.00.H.04434.00
F3.00.H.15434.00
F3.00.H.16434.00
L0
F3.00.H.05554.00
F3.00.H.06554.00
PVDF
F3.00.H.17554.00
F3.00.H.18554.00
L1
F3.00.H.07718.00
F3.00.H.08718.00
F3.00.H.19718.00
F3.00.H.20718.00
EPDM
Viton®
F3.01 IP68For Direct Mount For Panel or Wall Mount
Sensor Length
Body
O-Ring
F3.00 IP68
IP68 – NEMA 6, 6PSupplied with 6" long
cable, 22 AWG,3 conductors
Electrical ClassSensor Length
Body
0-Ring
EPDM
Viton®
L0
F3.01.H.09642.00
F3.01.H.10642.00
316L SS
L1
F3.01.H.11674.00
F3.01.H.12674.00
L0
F3.01.H.25515.00
F3.01.H.26515.00
L1
F3.01.H.27663.00
F3.01.H.28663.00
BrassNew
New
IP68 – NEMA 6, 6PSupplied with 8 m(26’) long cable, 22AWG, 3 conductors
Electrical Class
EPDM
Viton®
IP65 – NEMA 4, 4XSupplied with
4-pole cable plug(cable is not supplied)
L0
F3.00.H.09798.00
F3.00.H.10798.00
316L SS
F3.00.H.21798.00
F3.00.H.22798.00
L1
F3.00.H.11838.00
F3.00.H.12838.00
F3.00.H.23838.00
F3.00.H.24838.00
L0
F3.00.H.25 593.00
F3.00.H.26 593.00
F3.00.H.29 593.00
F3.00.H.30 593.00
L1
F3.00.H.27 741.00
F3.00.H.28 741.00
F3.00.H.31 741.00
F3.00.H.32 741.00
EPDM
Viton®
Sensor Length
Body
O-Ring
Brass
Type F3.01.C – for Direct Mounting to Instruments
Type F3.00.C – for Connection to Panel or Wall Mount Instruments
IP68 – NEMA 6, 6PSupplied with 6" long
cable, 22 AWG,3 conductors
L0
F3.01.C.01334.00
F3.01.C.02334.00
CPVCElectrical Class
EPDM
Viton®
L1
F3.01.C.03351.00
F3.01.C.04351.00
L0
F3.01.C.05453.00
F3.01.C.06453.00
PVDF
L1
F3.01.C.07637.00
F3.01.C.08637.00
IP68 – NEMA 6, 6PSupplied with 8 m(26’) long cable, 22AWG, 3 conductors
L0
F3.00.C.01414.00
F3.00.C.02414.00
CPVCElectrical Class
EPDM
Viton®
IP65 – NEMA 4, 4XSupplied with
4-pole cable plug(cable is not supplied)
F3.00.C.13414.00
F3.00.C.14414.00
L1
F3.00.C.03434.00
F3.00.C.04434.00
F3.00.C.15434.00
F3.00.C.16434.00
L0
F3.00.C.05554.00
F3.00.C.06554.00
PVDF
F3.00.C.17554.00
F3.00.C.18554.00
L1
F3.00.C.07718.00
F3.00.C.08718.00
F3.00.C.19718.00
F3.00.C.20718.00
EPDM
Viton®
Flow SensorsInstallation fittings are required for these paddle wheel typesensors. See pages 20 and 21 for fittings and to determine sensorlength required (L0 or L1).
Coil Effect SensorsCoil Effect Flow Sensors require a supply voltage between 3 and 5VDC. A square wave output signal is generated with frequencyproportional to flow velocity. The signal is normally fed to theF9.20 battery powered (3.6 V) flow monitor. See page 5.
Sensor Length
Body
O-Ring
Sensor Length
Body
O-Ring
Flow Sensors
IP68 – NEMA 6, 6PSupplied with 6" long
cable, 22 AWG,3 conductors
Electrical Class
EPDM
Viton®
L0
F3.01.C.25 515.00
F3.01.C.26 515.00
Brass
L1
F3.01.C.27 663.00
F3.01.C.28 663.00
L0
F3.01.C.09642.00
F3.01.C.10642.00
316L SS
L1
F3.01.C.11674.00
F3.01.C.12674.00
IP68 – NEMA 6, 6PSupplied with 8 m(26’) long cable, 22AWG, 3 conductors
Electrical Class
EPDM
Viton®
IP65 – NEMA 4, 4XSupplied with
4-pole cable plug(cable is not supplied)
L0
F3.00.C.25 593.00
F3.00.C.26 593.00
Brass
F3.00.C.29 593.00
F3.00.C.30 593.00
L1
F3.00.C.27 741.00
F3.00.C.28 741.00
F3.00.C.31 741.00
F3.00.C.32 741.00
L0
F3.00.C.09798.00
F3.00.C.10798.00
316L SS
F3.00.C.21798.00
F3.00.C.22798.00
L1
F3.00.C.11838.00
F3.00.C.12838.00
F3.00.C.23838.00
F3.00.C.24838.00
EPDM
Viton®
F3.00 IP65F3.01 IP68For Direct Mount For Panel or Wall Mount
Sensor Length
Body
O-Ring
Sensor Length
Body
O-Ring
F3.00 IP68
Price List USF05-1 3 Consult Chemline Plastics for availability.Subject to change without notice.
New
New
Flow Sensors
Type ULF.R – for Connection to Panel or Wall Mount Instruments
Flow Sensors for Hot-Tap InstallationIsolation valve and Hot-Tap installation fittings are required. See page 21.
Hall Effect SensorThe Hall Effect Type F111.H Flow Sensor requires a supply voltage between 5 and 24 VDC. A squarewave output signal is generated with frequency proportional to flow velocity. The signal is normallyfed to a F9.00, F9.01, F9.02, F9.03 or F9.50 Instrument. See page 5.
Ultra Low Flow SensorsSensors have male threaded in-line connections,1/4" BSP.Supplied with 2 m (6.5 ft) long cable.
Hall Effect SensorsULF Hall Effect Flow Sensors require a supply voltage between 5 and 24 VDC. A squarewave output signal is generated proportional to flow velocity. The signal is normallyfed to a F9.01, F9.02, F9.03 or F9.50 Instrument. See page 5.
F111
IP65 – NEMA 4, 4X
1.5 – 100 l/h 6 – 250 l/h 1.5 – 100 l/h 6 – 250 l/h 1.5 – 100 l/h 6 – 250 l/h
ULF01.H.0200.00
Electrical Class
ULF03.H.0200.00
ULF01.H.2444.00
ECTFE* Body / Viton® O-RingPOM† Body / Viton® O-Ring
ULF03.H.2444.00
ULF01.H.3694.00
ECTFE* Body / Kalrez O-Ring
ULF03.H.3694.00
Type ULF.H – for Connection to Panel or Wall Mount Instruments
Reed Effect SensorsULF Reed Sensors require no power supply. A square wave output signal (a volt free contact) is generated proportional to the flowvelocity. The signal is normally fed to the F9.20 battery powered (3.6 V) remote flow monitor or to the F9.00 flowmonitor/transmitter. See page 5.
PriceItem No.Pipe SizeSensor Body / Seal
304SS / Viton® 3" – 24" F111.H 2,638.00Brass 2" F111.H–Brass 1,648.00
Coil Effect Sensor The Coil Effect Type F111.C Flow Sensor requires a supply voltage between 3 to 5 VDC. A square wave output signal is generatedwith frequency proportional to flow velocity. The signal is normally fed to the F9.20 battery powered (3.6 V) flow monitor.See page 5.
Item No.Pipe SizeSensor Body / Seal
304SS / Viton® 3" – 24" F111.C 2,638.00Brass 2" F111.C–Brass 1,648.00
ULFF3.80
IP65 – NEMA 4, 4X
1.5 – 100 l/h 6 – 250 l/h 1.5 – 100 l/h 6 – 250 l/h 1.5 – 100 l/h 6 – 250 l/h
ULF01.R.0219.00
Electrical Class
ULF03.R.0219.00
ULF01.R.2418.00
ECTFE* Body / Viton® O-RingPOM† Body / Viton® O-Ring
ULF03.R.2418.00
ULF01.R.3653.00
ECTFE* Body / Kalrez O-Ring
ULF03.R.3653.00
† POM = "Polyoxymethylene". * ECTFE is also referred to as "Halar®".
† POM = "Polyoxymethylene". * ECTFE is also referred to as "Halar®".
Type F3.80 Oval Gear Flow Sensors – for High Viscosity Fluid MeasurementType F3.80 Flow Sensors require a supply voltage between 5 and 24 VDC. A square wave output signal is generated proportionalto flow velocity. The signal is normally fed to a F9.01, F9.02, F9.03 or F9.50 Instrument. See page 5.
IP65 – NEMA 4, 4X
10 – 100 l/h 25 – 250 l/h 10 – 100 l/h 25 – 250 l/h 10 – 100 l/h 25 – 250 l/h
F3.81.H.01728.00
Electrical Class
F3.82.H.01728.00
F3.81.H.021,072.00
ECTFE / ECTFE GearsPP / ECTFE Gears
F3.82.H.021,072.00
F3.81.H.031,360.00
316L SS / ECTFE Gears
F.3.82.H.031,366.00
Type F3.80 – for Connection to Panel or Wall Mount Instruments
Special versions with 4–20 mA output or alarm output are available on request.
4 Price List USF05-1 Consult Chemline Plastics for availability.Subject to change without notice.
New
New
New
Price
Instruments
Types F9.00, F9.01, F9.02, F9.03 – Flow Monitor and TransmitterRequired Supply Voltage: 12 – 24 VDCDisplays: Flow Rate – 5 digits
Resettable Total – 6 digitsNon-Resettable Total – 10 digits
F9.20
F9.50
F9.00, F9.01, F9.02, F9.03
PriceItem No.No. of LEDsOutputs
Outputs
Type F9.50 – Batch ControllerRequired Supply Voltage: 12 – 24 VDCDisplays: Batch in Progress – 6 digits
Flow Rate – 5 digitsResettable Total – 6 digitsNon-Resettable Total – 10 digits
Type F9.20 – Battery Powered Flow MonitorPower Supply: 2 x 3.6 Volt Lithium Batteries (included)Displays: Flow Rate – 5 digits
Resettable Total – 6 digitsNon-Resettable Total – 10 digits
Instrument Mounting KitsMounting kits are required for installation of the 1/4 DINinstruments above. The direct mount kit is for connecting theinstrument directly to a paddle wheel flow sensor. The panel orwall mount kits are for remote installations.
InstrumentsInstruments are 1/4 DIN size with monolithic NEMA 4X polycarbonate enclosure,epoxy encapsulated electronics with 5 button silicone rubber key pad, 3-line LCDdisplay and output indicating LEDs (except battery powered unit). Modular designallows the same unit to be mounted in different ways. See Instrument Mounting Kitsbelow. Set up is easy using the key pad and self-explanatory menus.
Panel Mount KitDirect Mount Kit Wall Mount Kit
PriceApplication Description Item No.Direct Mount ABS enclosure with EPDM gasket, cap, locking ring F9.KC1 86.00and 4 screwsPanel Mount Metal mounting clip with Neoprene foam gasket F9.KP1 36.00Wall Mount 1 ABS box with EPDM gasket and screws F9.KW1 58.00Wall Mount 2 ABS box with EPDM gasket, screws and F9.KW2 132.00110/230 VAC to 24 VDC transformer included
PriceItem No.
PriceItem No.
4 – 20 mA 2 wire, 1 open collector* 1 F9.00 657.004 – 20 mA 3/4 wire, 3 open collectors* 3 F9.01 685.004 – 20 mA 3/4 wire, 1 open collector*, 2 SPDT relays† 3 F9.02 697.004 – 20 mA 3/4 wire, 1 open collector*, 2 SPDT relays† 3 F9.03 980.00Accepts input from 2 Hall Effect Sensors, Output and Displays for both sensors are same as above.
No. of LEDs
Outputs No. of LEDs
None – Flow Rate and Total indication only 0 F9.20 885.00
4 – 20 mA 3/4 wire, 1 open collector**, 2 SPDT relays†† 3 F9.50 760.00
* Open Collector is selectable as MIN alarm, MAX alarm, Pulse (i.e. 1 pulse per 10 gallons) or Frequency (scaleable).† Relay is selectable as MIN alarm, MAX alarm or Pulse (i.e. one pulse per 10 gallons).
** Open collector is selectable as START Batch or END Batch.†† Relay OUT1 is batch in progress indication.
Relay OUT2 is selectable as two-stage shutdown, end ofbatch, overrun alarm or missing signal alarm.
Price List USF05-1 5 Consult Chemline Plastics for availability.Subject to change without notice.
New
Flow Switches
IP65 – NEMA 4, 4XSupplied with 4-pole
cable plug(cable is not supplied)
L0
F3.05.01404.00
F3.05.02404.00
CPVCElectrical Class
EPDM
Viton®
L1
F3.05.03428.00
F3.05.04428.00
L0
F3.05.05631.00
F3.05.06631.00
PVDF
L1
F3.05.07671.00
F3.05.08671.00
Adjustable Flow SwitchesType F3.15 and ULF3.15 Adjustable Flow Switches requires a supply voltage between 12 and 24 VDC. The MIN alarm set point canbe adjusted for velocity from 0.15 to 1 m/s (0.5 to 3.3 ft/s). Switch output is an SPDT relay. Switch delay is 3 or 10 seconds. Abicolour LED indicator shows: Red = no flow and Green = flow. Included is one open collector (frequency) output which may besent to an instrument for flow rate monitoring.
Type F3.15 – Paddle Wheel Installation fittings are required.††
Type ULF3.15 – Ultra-Low Flow End connections are male threaded, in-line 1/4" BSP.
Flow SwitchesType F3.05 – No-Flow SwitchesType F3.05 No-Flow Switches have a paddle wheel type flow sensor.They require a supply voltage between 12 and 24 VDC. Output is anormally open SPST switch. Switch point is at a velocity of 0.15m/sec. (0.5ft/sec.), not adjustable. Delay is 2 seconds. A bicolourLED indicator shows: Red = no flow and Green = flow. Installationfittings are required.††
IP65 – NEMA 4, 4X
L0
F3.15.H.01512.00
F3.15.H.02512.00
CPVCElectrical Class
EPDM
Viton®
L1
F3.15.H.03529.00
F3.15.H.04529.00
L0
F3.15.H.05631.00
F3.15.H.06631.00
PVDF
L1
F3.15.H.07815.00
F3.15.H.08815.00
F3.15 ULF3.15F3.05
IP65 – NEMA 4, 4X
1.5 – 21 l/h 6 – 53 l/h 1.5 – 21 l/h 6 – 53 l/h 1.5 – 21 l/h 6 – 53 l/h
ULF3.15.01.0516.00
Electrical Class
ULF3.15.03.0541.00
ULF3.15.01.2750.00
ECTFE* Body / Viton® O-RingPOM† Body / Viton® O-Ring
ULF3.15.03.2804.00
ULF3.15.01.3945.00
ECTFE* Body / Kalrez O-Ring
ULF3.15.03.3981.00
Sensor Length
Body
O-Ring
Sensor Length
Body
O-Ring
6 Price List USF05-1 Consult Chemline Plastics for availability.Subject to change without notice.
1.5 – 100 l/h 6 – 250 l/h 1.5 – 100 l/h 6 – 250 l/h 1.5 – 100 l/h 6 – 250 l/h
Flow Rate
Trip Point
IP65 – NEMA 4, 4XSupplied with 4-pole
cable plug(cable is not supplied)
Electrical Class
EPDM
Viton®
L0
F3.05.09766.00
F3.05.10766.00
316L SS
L1
F3.05.11806.00
F3.05.12806.00
L0
F3.05.13647.00
F3.05.14647.00
Brass
L1
F3.05.15703.00
F3.05.16703.00
Sensor Length
Body
O-Ring
New
New
† POM = "Polyoxymethylene". * ECTFE is also referred to as "Halar®". †† See pages 20 and 21 for fittings and to determine sensor length required (L0 or L1).
IP65 – NEMA 4, 4X
Electrical Class
EPDM
Viton®
L0
F3.15.H.09821.00
F3.15.H.10821.00
316L SS
L1
F3.15.H.11852.00
F3.15.H.12852.00
L0
F3.15.H.13 671.00
F3.15.H.14 671.00
Brass
L1
F3.15.H.15 818.00
F3.15.H.16 818.00
Sensor Length
Body
O-Ring
Blind Transmitters
Blind TransmittersType F3.30 transmitters have no display. Required supply voltage is 12 to 24 VDC.Output is 4 to 20 mA 3 wire.
IP65 – NEMA 4, 4X
Electrical Class
EPDM
Viton®
L0
F3.30.H.091,071.00
F3.30.H.101,071.00
316L SS
L1
F3.30.H.111,104.00
F3.30.H.121,104.00
L0
F3.30.H.13 952.00
F3.30.H.14 952.00
Brass
L1
F3.30.H.15 1,069.00
F3.30.H.16 1,069.00
Sensor Length
Body
O-Ring
Price List USF05-1 7 Consult Chemline Plastics for availability.Subject to change without notice.
New
Type F3.30 – Paddle Wheel Installation fittings are required.††
IP65 – NEMA 4, 4X
L0
F3.30.H.01763.00
F3.30.H.02763.00
CPVCElectrical Class
EPDM
Viton®
L1
F3.30.H.03780.00
F3.30.H.04780.00
L0
F3.30.H.05882.00
F3.30.H.06882.00
PVDF
L1
F3.30.H.071,066.00
F3.30.H.081,066.00
Type ULF3.30 – Ultra-Low Flow End connections are male threaded, in-line 1/4" BSP.
IP65 – NEMA 4, 4X
1.5 – 100 l/h 6 – 250 l/h 1.5 – 100 l/h 6 – 250 l/h 1.5 – 100 l/h 6 – 250 l/h
ULF3.30.01.0599.00
Electrical Class
ULF3.30.03.0624.00
ULF3.30.01.2828.00
ECTFE* Body / Viton® O-RingPOM† Body / Viton® O-Ring
ULF3.30.03.2871.00
ULF3.30.01.31,014.00
ECTFE* Body / Kalrez O-Ring
ULF3.30.03.31,057.00
Sensor Length
Body
O-Ring
† POM = "Polyoxymethylene". * ECTFE is also referred to as "Halar®". †† See pages 20 and 21 for fittings and to determine sensor length required (L0 or L1).
F3.30 ULF3.30
Packages
8 Price List USF05-1 Consult Chemline Plastics for availability.Subject to change without notice.
Panel Mount InstrumentDirect Mount Package Wall Mount Instrument
F9.00 Monitor/Transmitter PackagesF9.00 Monitor/Transmitter packages come complete with:
1. F9.00 Flow Monitor and Transmitter. See page 5.2. Instrument Mounting Kit. See page 5.3. Flow Sensor F3.01.H or F3.00.H. See page 2.
(Power supply provided by the flow monitor).
See pages noted for component descriptions and unit prices.
Installation fittings are required for these paddle wheel typesensors. See pages 20 and 21 for fittings and to determine sensorlength required (L0 or L1).
Displays: Flow Rate – 5 digits,Resettable Total – 6 digitsNon-resettable Total – 10 digits
Outputs: 4 to 20 mA 2 wire plus 1 open collectorLEDs: 1
L0
CPVCConfiguration Required Voltage L1 L0
PVDF
L1
Direct Mount12 – 24 VDC
Panel Mount12 – 24 VDC
L0
F9.00.011,077.00
F9.00.021,077.00
F9.00.P1.011,107.00
F9.00.P1.021,107.00
CPVCConfiguration Required Voltage
EPDM
Viton®
EPDM
Viton®
Wall Mount 112 – 24 VDC
F9.00.W1.011,129.00
F9.00.W1.021,129.00
L1
F9.00.031,094.00
F9.00.041,094.00
F9.00.P1.031,127.00
F9.00.P1.041,127.00
F9.00.W1.031,149.00
F9.00.W1.041,149.00
L0
F9.00.051,196.00
F9.00.061,196.00
F9.00.P1.051,247.00
F9.00.P1.061,247.00
PVDF
F9.00.W1.051,269.00
F9.00.W1.061,269.00
L1
F9.00.071,380.00
F9.00.081,380.00
F9.00.P1.071,411.00
F9.00.P1.081,411.00
F9.00.W1.071,433.00
F9.00.W1.081,433.00
Wall Mount 2110 – 230 VAC
Components
Instrument – F9.00Mounting Kit – F9.KP1
Sensor – F3.00.H.xx
Instrument – F9.00Mounting Kit – F9.KW1
Sensor – F3.00.H.xx
Instrument – F9.00Mounting Kit – F9.KW2
Sensor – F3.00.H.xx
F9.00.W2.011,203.00
F9.00.W2.021,203.00
EPDM
Viton®
F9.00.W2.031,223.00
F9.00.W2.041,223.00
F9.00.W2.051,343.00
F9.00.W2.061,343.00
F9.00.W2.071,507.00
F9.00.W2.081,507.00
EPDM
Viton®
Sensor Electrical Class – IP68 (NEMA 6, 6P), supplied with 8 m (26 ft.) long cable, 22 AWG, 3 conductors.
F3.00.H IP68F3.00.H IP65
Sensor Length
Body
O-Ring
Sensor Length
Body
O-Ring
Panel Mount12 – 24 VDC
Wall Mount 112 – 24 VDC
F9.00.P1.131,107.00
F9.00.P1.141,107.00
F9.00.W1.131,129.00
F9.00.W1.141,129.00
EPDM
Viton®
EPDM
Viton®
Wall Mount 2110 – 230 VAC
Instrument – F9.00Mounting Kit – F9.KC1
Sensor – F3.01.H.xx
Components
Instrument – F9.00 Mounting Kit – F9.KP1
Sensor – F3.00.H.xx
Instrument – F9.00Mounting Kit – F9.KW1
Sensor – F3.00.H.xx
Instrument – F9.00Mounting Kit – F9.KW2
Sensor – F3.00.H.xx
F9.00.W2.131,203.00
F9.00.W2.141,203.00
F9.00.P1.151,127.00
F9.00.P1.161,127.00
F9.00.W1.151,149.00
F9.00.W1.161,149.00
F9.00.W2.151,223.00
F9.00.W2.161,223.00
F9.00.P1.171,247.00
F9.00.P1.181,247.00
F9.00.W1.171,269.00
F9.00.W1.181,269.00
F9.00.W2.171,343.00
F9.00.W2.181,343.00
F9.00.P1.191,411.00
F9.00.P1.201,411.00
F9.00.W1.191,433.00
F9.00.W1.201,433.00
F9.00.W2.191,507.00
F9.00.W2.201,507.00
EPDM
Viton®
Sensor Electrical Class – IP65 (NEMA 4, 4X), supplied with 4 pole cable plug for remote installation (cable is not supplied).
Packages
Panel Mount InstrumentDirect Mount Package Wall Mount Instrument
F9.00 Monitor/Transmitter PackagesF9.00 Monitor/Transmitter packages come complete with:
1. F9.00 Flow Monitor and Transmitter. See page 5.2. Instrument Mounting Kit. See page 5.3. Flow Sensor F3.01.H or F3.00.H. See page 2.
(Power supply provided by the flow monitor).
See pages noted for component descriptions and unit prices.
Installation fittings are required for these paddle wheel typesensors. See pages 20 and 21 for fittings and to determine sensorlength required (L0 or L1).
Displays: Flow Rate – 5 digits,Resettable Total – 6 digitsNon-resettable Total – 10 digits
Outputs: 4 to 20 mA 2 wire plus 1 open collectorLEDs: 1
Configuration Required Voltage L0
316L SS
L1
Direct Mount12 – 24 VDC
Panel Mount12 – 24 VDC
Configuration Required Voltage
EPDM
Viton®
EPDM
Viton®
Wall Mount 112 – 24 VDC
L0
F9.00.091,385.00
F9.00.101,385.00
F9.00.P1.091,491.00
F9.00.P1.101,491.00
316L SS Brass
F9.00.W1.091,513.00
F9.00.W1.101,513.00
L1
F9.00.111,417.00
F9.00.121,417.00
F9.00.P1.111,531.00
F9.00.P1.121,531.00
Wall Mount 2110 – 230 VAC
Components
Instrument – F9.00Mounting Kit – F9.KP1
Sensor – F3.00.H.xx
Instrument – F9.00Mounting Kit – F9.KW1
Sensor – F3.00.H.xx
Instrument – F9.00Mounting Kit – F9.KW1
Sensor – F3.00.H.xx
EPDM
Viton®
F9.00.W2.091,587.00
F9.00.W2.101,587.00
F9.00.W2.111,627.00
F9.00.W2.121,627.00
F9.00.W1.111,553.00
F9.00.W1.121,553.00
L0
Brass
L1
F9.00.P1.251,286.00
F9.00.P1.261,286.00
F9.00.W1.251,308.00
F9.00.W1.261,308.00
F9.00.P1.271,434.00
F9.00.P1.281,434.00
F9.00.W2.251,382.00
F9.00.W2.261,382.00
F9.00.W2.271,530.00
F9.00.W2.281,530.00
F9.00.W1.271,456.00
F9.00.W1.281,456.00
EPDM
Viton®
Sensor Electrical Class – IP68 (NEMA 6, 6P), supplied with 8 m (26 ft.) long cable, 22 AWG, 3 conductors.
F3.00.H IP68F3.00.H IP65
Sensor Length
Body
O-Ring
Sensor Length
Body
O-Ring
Panel Mount12 – 24 VDC
Wall Mount 112 – 24 VDC
EPDM
Viton®
EPDM
Viton®
Wall Mount 2110 – 230 VAC
Instrument – F9.00Mounting Kit – F9.KC1
Sensor – F3.01.H.xx
Components
Instrument – F9.00Mounting Kit – F9.KP1
Sensor – F3.00.H.xx
Instrument – F9.00Mounting Kit – F9.KW1
Sensor – F3.00.H.xx
Instrument – F9.00Mounting Kit – F9.KW2
Sensor – F3.00.H.xx
F9.00.P1.211,491.00
F9.00.P1.221,491.00
F9.00.W1.211,513.00
F900.W1.221,513.00
F9.00.W2.211,587.00
F9.00.W2.221,587.00
F9.00.P1.231,531.00
F9.00.P1.241,531.00
F9.00.W1.231,553.00
F9.00.W1.241,553.00
F9.00.W2.231,627.00
F9.00.W2.241,627.00
L0
F9.00.251,258.00
F9.00.261,258.00
L1
F9.00.271,406.00
F9.00.281,406.00
F9.00.P1.291,286.00
F9.00.P1.301,286.00
F9.00.W1.291,308.00
F9.00.W1.301,308.00
F9.00.W2.291,382.00
F9.00.W2.301,382.00
F9.00.P1.311,434.00
F9.00.P1.321,434.00
F9.00.W1.311,456.00
F9.00.W1.321,456.00
F9.00.W2.311,530.00
F9.00.W2.321,530.00
EPDM
Viton®
Price List USF05-1 9Consult Chemline Plastics for availability.Subject to change without notice.
Sensor Electrical Class – IP65 (NEMA 4, 4X), supplied with 4 pole cable plug for remote installation (cable is not supplied).
New
New
Packages
Panel Mount InstrumentDirect Mount Package Wall Mount Instrument
F9.01 Monitor/Transmitter Packages F9.01 Monitor/Transmitter packages come complete with:
1. F9.01 Flow Monitor and Transmitter. See page 5.2. Instrument Mounting Kit. See page 5.3. Flow Sensor F3.01.H or F3.00.H. See page 2.
(Power supply provided by the flow monitor).
See pages noted for component descriptions and unit prices.
Installation fittings are required for these paddle wheel typesensors. See pages 20 and 21 for fittings and to determine sensorlength required (L0 or L1).
Displays: Flow Rate – 5 digitsResettable Total – 6 digitsNon-resettable Total – 10 digits
Outputs: 4 to 20 mA 3/4 wire plus 3 open collectorsLEDs: 3
L0
CPVCConfiguration Required Voltage L1 L0
PVDF
L1
Direct Mount12 – 24 VDC
L0
F9.01.011,105.00
F9.01.021,105.00
CPVCConfiguration Required Voltage
EPDM
Viton®
L1
F9.01.031,122.00
F9.01.041,122.00
L0
F9.01.051,224.00
F9.01.061,224.00
PVDF
L1
F9.01.071,408.00
F9.01.081,408.00
Sensor Electrical Class – IP68 (NEMA 6, 6P), supplied with 8 m (26 ft.) long cable, 22 AWG, 3 conductors.
Sensor Electrical Class – IP65 (NEMA 4, 4X), supplied with 4 pole cable plug for remote installation (cable is not supplied).
F3.00.H IP68F3.00.H IP65
Sensor Length
Body
O-Ring
Sensor Length
Body
O-Ring
Panel Mount12 – 24 VDC
Wall Mount 112 – 24 VDC
F9.01.P1.131,135.00
F9.01.P1.141,135.00
F9.01.W1.131,157.00
F9.01.W1.141,157.00
EPDM
Viton®
EPDM
Viton®
Wall Mount 2110 – 230 VAC
Instrument – F9.01Mounting Kit – F9.KC1
Sensor – F3.01.H.xx
Components
Instrument – F9.01Mounting Kit – F9.KP1
Sensor – F3.00.H.xx
Instrument – F9.01Mounting Kit – F9.KW1
Sensor – F3.00.H.xx
Instrument – F9.01Mounting Kit – F9.KW2
Sensor – F3.00.H.xx
F9.01.W2.131,231.00
F9.01.W2.141,231.00
F9.01.P1.151,155.00
F9.01.P1.161,155.00
F9.01.W1.151,177.00
F9.01.W1.161,177.00
F9.01.W2.151,251.00
F9.01.W2.161,251.00
F9.01.P1.171,275.00
F9.01.P1.181,275.00
F9.01.W1.171,297.00
F9.01.W1.181,297.00
F9.01.W2.171,371.00
F9.01.W2.181,371.00
F9.01.P1.191,439.00
F9.01.P1.201,439.00
F9.01.W1.191,461.00
F9.01.W1.201,461.00
F9.01.W2.191,535.00
F9.01.W2.201,535.00
EPDM
Viton®
Panel Mount12 – 24 VDC
F9.01.P1.011,135.00
F9.01.P1.021,135.00
EPDM
Viton®
Wall Mount 112 – 24 VDC
F9.01.W1.011,157.00
F9.01.W1.021,157.00
F9.01.P1.031,155.00
F9.01.P1.041,155.00
F9.01.W1.031,177.00
F9.01.W1.041,177.00
F9.01.P1.051,275.00
F9.01.P1.061,275.00
F9.01.W1.051,297.00
F9.01.W1.061,297.00
F9.01.P1.071,439.00
F9.01.P1.081,439.00
F9.01.W1.071,461.00
F9.01.W1.081,461.00
Wall Mount 2110 – 230 VAC
Components
Instrument – F9.01Mounting Kit – F9.KP1
Sensor – F3.00.H.xx
Instrument – F9.01Mounting Kit – F9.KW1
Sensor – F3.00.H.xx
Instrument – F9.01Mounting Kit – F9.KW2
Sensor – F3.00.H.xx
F9.01.W2.011,231.00
F9.01.W2.021,231.00
EPDM
Viton®
F9.01.W2.031,251.00
F9.01.W2.041,251.00
F9.01.W2.051,371.00
F9.01.W2.061,371.00
F9.01.W2.071,535.00
F9.01.W2.081,535.00
EPDM
Viton®
10 Price List USF05-1 Consult Chemline Plastics for availability.Subject to change without notice.
Packages
Panel Mount InstrumentDirect Mount Package Wall Mount Instrument
F9.01 Monitor/Transmitter Packages F9.01 Monitor/Transmitter packages come complete with:
1. F9.01 Flow Monitor and Transmitter. See page 5.2. Instrument Mounting Kit. See page 5.3. Flow Sensor F3.01.H or F3.00.H. See page 2.
(Power supply provided by the flow monitor).
See pages noted for component descriptions and unit prices.
Installation fittings are required for these paddle wheel typesensors. See pages 20 and 21 for fittings and to determine sensorlength required (L0 or L1).
Displays: Flow Rate – 5 digitsResettable Total – 6 digitsNon-resettable Total – 10 digits
Outputs: 4 to 20 mA 3/4 wire plus 3 open collectorsLEDs: 3
Configuration Required Voltage L0
316L SS
L1
Direct Mount12 – 24 VDC
Configuration Required Voltage
EPDM
Viton®
L0
F9.01.091,413.00
F9.01.101,413.00
316L SS
L1
F9.01.111,445.00
F9.01.121,445.00
Sensor Electrical Class – IP68 (NEMA 6, 6P), supplied with 8 m (26 ft.) long cable, 22 AWG, 3 conductors.
Sensor Electrical Class – IP65 (NEMA 4, 4X), supplied with 4 pole cable plug for remote installation (cable is not supplied).
F3.00.H IP68F3.00.H IP65
Sensor Length
Body
O-Ring
Sensor Length
Body
O-Ring
Panel Mount12 – 24 VDC
Wall Mount 112 – 24 VDC
EPDM
Viton®
EPDM
Viton®
Wall Mount 2110 – 230 VAC
Instrument – F9.01Mounting Kit – F9.KC1
Sensor – F3.01.H.xx
Components
Instrument – F9.01Mounting Kit – F9.KP1
Sensor – F3.00.H.xx
Instrument – F9.01Mounting Kit – F9.KW1
Sensor – F3.00.H.xx
Instrument – F9.01Mounting Kit – F9.KW2
Sensor – F3.00.H.xx
F9.01.P1.211,519.00
F9.01.P1.221,519.00
F9.01.W1.211,541.00
F9.01.W1.221,541.00
F9.01.W2.211,615.00
F9.01.W2.221,615.00
F9.01.P1.231,559.00
F9.01.P1.241,559.00
F9.01.W1.231,581.00
F9.01.W1.241,581.00
F9.01.W2.231,655.00
F9.01.W2.241,655.00
L0
F9.01.251,286.00
F9.01.261,286.00
Brass
L1
F9.01.271,434.00
F9.01.281,434.00
F9.01.P1.291,314.00
F9.01.P1.301,314.00
F9.01.W1.291,336.00
F9.01.W1.301,336.00
F9.01.W2.291,410.00
F9.01.W2.301,410.00
F9.01.P1.311,462.00
F9.01.P1.321,462.00
F9.01.W1.311,484.00
F9.01.W1.321,484.00
F9.01.W2.311,558.00
F9.01.W2.321,558.00
EPDM
Viton®
Panel Mount12 – 24 VDC
EPDM
Viton®
Wall Mount 112 – 24 VDC
F9.01.P1.091,519.00
F9.01.P1.101,519.00
F9.01.W1.091,541.00
F9.01.W1.101,541.00
F9.01.P1.111,559.00
F9.01.P1.121,559.00
Wall Mount 2110 – 230 VAC
Components
Instrument – F9.01Mounting Kit – F9.KP1
Sensor – F3.00.H.xx
Instrument – F9.01Mounting Kit – F9.KW1
Sensor – F3.00.H.xx
Instrument – F9.01Mounting Kit – F9.KW2
Sensor – F3.00.H.xx
EPDM
Viton®
F9.01.W2.091,615.00
F9.01.W2.101,615.00
F9.01.W2.111,655.00
F9.01.W2.121,655.00
F9.01.W1.111,581.00
F9.01.W1.121,581.00
L0
Brass
L1
F9.01.P1.251,314.00
F9.01.P1.261,314.00
F9.01.W1.251,336.00
F9.01.W1.261,336.00
F9.01.P1.271,462.00
F9.01.P1.281,462.00
F9.01.W2.251,410.00
F9.01.W2.261,410.00
F9.01.W2.271,558.00
F9.01.W2.281,558.00
F9.01.W1.271,484.00
F9.01.W1.281,484.00
EPDM
Viton®
Price List USF05-1 11Consult Chemline Plastics for availability.Subject to change without notice.
New
New
Packages
Panel Mount InstrumentDirect Mount Package Wall Mount Instrument
F9.02 Monitor/Transmitter Packages F9.02 Monitor/Transmitter packages come complete with:
1. F9.02 Flow Monitor and Transmitter. See page 5.2. Instrument Mounting Kit. See page 5.3. Flow Sensor F3.01.H or F3.00.H. See page 2.
(Power supply provided by the flow monitor).
See pages noted for component descriptions and unit prices.
Installation fittings are required for these paddle wheel typesensors. See pages 20 and 21 for fittings and to determine sensorlength required (L0 or L1).
Displays: Flow Rate – 5 digitsResettable Total – 6 digitsNon-resettable Total – 10 digits
Outputs: 4 to 20 mA 3/4 wire plus 1 open collectorand 2 SPDT relays
LEDs: 3
L0
CPVCConfiguration Required Voltage L1 L0
PVDF
L1
Direct Mount12 – 24 VDC
Panel Mount12 – 24 VDC
L0
F9.02.011,117.00
F9.02.021,117.00
F9.02.P1.011,147.00
F9.02.P1.021,147.00
CPVCConfiguration Required Voltage
EPDM
Viton®
EPDM
Viton®
Wall Mount 112 – 24 VDC
F9.02.W1.011,169.00
F9.02.W1.021,169.00
L1
F9.02.031,134.00
F9.02.041,134.00
F9.02.P1.031,167.00
F9.02.P1.041,167.00
F9.02.W1.031,189.00
F9.02.W1.041,189.00
L0
F9.02.051,236.00
F9.02.061,236.00
F9.02.P1.051,287.00
F9.02.P1.061,287.00
PVDF
F9.02.W1.051,309.00
F9.02.W1.061,309.00
L1
F9.02.071,420.00
F9.02.081,420.00
F9.02.P1.071,451.00
F9.02.P1.081,451.00
F9.02.W1.071,473.00
F9.02.W1.081,473.00
Wall Mount 2110 – 230 VAC
Components
Instrument – F9.02Mounting Kit – F9.KP1
Sensor – F3.00.H.xx
Instrument – F9.02Mounting Kit – F9.KW1
Sensor – F3.00.H.xx
Instrument – F9.02Mounting Kit – F9.KW2
Sensor – F3.00.H.xx
F9.02.W2.011,243.00
F9.02.W2.021,243.00
EPDM
Viton®
F9.02.W2.031,263.00
F9.02.W2.041,263.00
F9.02.W2.051,383.00
F9.02.W2.061,383.00
F9.02.W2.071,547.00
F9.02.W2.081,547.00
EPDM
Viton®
Sensor Electrical Class – IP68 (NEMA 6, 6P), supplied with 8 m (26 ft.) long cable, 22 AWG, 3 conductors.
Sensor Length
Body
O-Ring
Sensor Length
Body
O-Ring
F3.00.H IP68F3.00.H IP65
Panel Mount12 – 24 VDC
Wall Mount 112 – 24 VDC
F9.02.P1.131,147.00
F9.02.P1.141,147.00
F9.02.W1.131,169.00
F9.02.W1.141,169.00
EPDM
Viton®
EPDM
Viton®
Wall Mount 2110 – 230 VAC
Instrument – F9.02Mounting Kit – F9.KC1
Sensor – F3.01.H.xx
Components
Instrument – F9.02Mounting Kit – F9.KP1
Sensor – F3.00.H.xx
Instrument – F9.02Mounting Kit – F9.KW1
Sensor – F3.00.H.xx
Instrument – F9.02Mounting Kit – F9.KW2
Sensor – F3.00.H.xx
F9.02.W2.131,243.00
F9.02.W2.141,243.00
F9.02.P1.151,167.00
F9.02.P1.161,167.00
F9.02.W1.151,189.00
F9.02.W1.161,189.00
F9.02.W2.151,263.00
F9.02.W2.161,263.00
F9.02.P1.171,287.00
F9.02.P1.181,287.00
F9.02.W1.171,309.00
F9.02.W1.181,309.00
F9.02.W2.171,383.00
F9.02.W2.181,383.00
F9.02.P1.191,451.00
F9.02.P1.201,451.00
F9.02.W1.191,473.00
F9.02.W1.201,473.00
F9.02.W2.191,547.00
F9.02.W2.201,547.00
EPDM
Viton®
12 Price List USF05-1 Consult Chemline Plastics for availability.Subject to change without notice.
Sensor Electrical Class – IP65 (NEMA 4, 4X), supplied with 4 pole cable plug for remote installation (cable is not supplied).
Packages
Panel Mount InstrumentDirect Mount Package Wall Mount Instrument
F9.02 Monitor/Transmitter Packages F9.02 Monitor/Transmitter packages come complete with:
1. F9.02 Flow Monitor and Transmitter. See page 5.2. Instrument Mounting Kit. See page 5.3. Flow Sensor F3.01.H or F3.00.H. See page 2.
(Power supply provided by the flow monitor).
See pages noted for component descriptions and unit prices.
Installation fittings are required for these paddle wheel typesensors. See pages 20 and 21 for fittings and to determine sensorlength required (L0 or L1).
Displays: Flow Rate – 5 digitsResettable Total – 6 digitsNon-resettable Total – 10 digits
Outputs: 4 to 20 mA 3/4 wire plus 1 open collectorand 2 SPDT relays
LEDs: 3
Configuration Required Voltage L0
316L SS
L1
Direct Mount12 – 24 VDC
Panel Mount12 – 24 VDC
Configuration Required Voltage
EPDM
Viton®
EPDM
Viton®
Wall Mount 112 – 24 VDC
L0
F9.02.091,425.00
F9.02.101,425.00
F9.02.P1.091,531.00
F9.02.P1.101,531.00
316L SS
F9.02.W1.091,553.00
F9.02.W1.101,553.00
L1
F9.02.111,457.00
F9.02.121,457.00
F9.02.P1.111,571.00
F9.02.P1.121,57100
Wall Mount 2110 – 230 VAC
Components
Instrument – F9.02Mounting Kit – F9.KP1
Sensor – F3.00.H.xx
Instrument – F9.02Mounting Kit – F9.KW1
Sensor – F3.00.H.xx
Instrument – F9.02Mounting Kit – F9.KW2
Sensor – F3.00.H.xx
EPDM
Viton®
F9.02.W2.091,627.00
F9.02.W2.101,627.00
F9.02.W2.111,667.00
F9.02.W2.121,667.00
F9.02.W1.111,593.00
F9.02.W1.121,593.00
L0
Brass
L1
F9.02.P1.251,326.00
F9.02.P1.261,326.00
F9.02.W1.251,348.00
F9.02.W1.261,348.00
F9.02.P1.271,474.00
F9.02.P1.281,474.00
F9.02.W2.251,422.00
F9.02.W2.261,422.00
F9.02.W2.271,570.00
F9.02.W2.281,570.00
F9.02.W1.271,496.00
F9.02.W1.281,496.00
EPDM
Viton®
Sensor Electrical Class – IP68 (NEMA 6, 6P), supplied with 8 m (26 ft.) long cable, 22 AWG, 3 conductors.
Sensor Length
Body
O-Ring
Sensor Length
Body
O-Ring
F3.00.H IP68F3.00.H IP65
Panel Mount12 – 24 VDC
Wall Mount 112 – 24 VDC
EPDM
Viton®
EPDM
Viton®
Wall Mount 2110 – 230 VAC
Instrument – F9.02Mounting Kit – F9.KC1
Sensor – F3.01.H.xx
Components
Instrument – F9.02Mounting Kit – F9.KP1
Sensor – F3.00.H.xx
Instrument – F9.02Mounting Kit – F9.KW1
Sensor – F3.00.H.xx
Instrument – F9.02Mounting Kit – F9.KW2
Sensor – F3.00.H.xx
F9.02.P1.211,531.00
F9.02.P1.221,531.00
F9.02.W1.211,553.00
F9.02.W1.221,553.00
F9.02.W2.211,627.00
F9.02.W2.221,627.00
F9.02.P1.231,571.00
F9.02.P1.241,571.00
F9.02.W1.231,593.00
F9.02.W1.241,593.00
F9.02.W2.231,667.00
F9.02.W2.241,667.00
L0
F9.02.251,298.00
F9.02.261,298.00
Brass
L1
F9.02.271,446.00
F9.02.281,446.00
F9.02.P1.291,326.00
F9.02.P1.301,326.00
F9.02.W1.291,348.00
F9.02.W1.301,348.00
F9.02.W2.291,422.00
F9.02.W2.301,422.00
F9.02.P1.311,474.00
F9.02.P1.321,474.00
F9.02.W1.311,496.00
F9.02.W1.321,496.00
F9.02.W2.311,570.00
F9.02.W2.321,570.00
EPDM
Viton®
Price List USF05-1 13 Consult Chemline Plastics for availability.Subject to change without notice.
Sensor Electrical Class – IP65 (NEMA 4, 4X), supplied with 4 pole cable plug for remote installation (cable is not supplied).
New
New
Packages
F9.20 Battery Powered Flow MonitorPackagesF9.20 Battery Powered Flow Monitor packages come complete with:
1. F9.20 Flow Monitor. See page 5.2. Instrument Mounting Kit. See page 5.3. Flow Sensor F3.01.C or F3.00.C. See page 3.
(Power supply provided by the flow monitor).
See pages noted for component descriptions and unit prices.
Installation fittings are required for these paddle wheel typesensors. See pages 20 and 21 for fittings and to determine sensorlength required (L0 or L1).
Displays: Flow Rate – 5 digitsResettable Total – 6 digitsNon-resettable Total – 10 digits
Outputs: NoneLEDs: None
Direct Mount2 x 3.6 Volt
Battery
L0
F9.20.011,305.00
F9.20.021,305.00
CPVCConfiguration Voltage
EPDM
Viton®
L1
F9.20.031,322.00
F9.20.041,322.00
L0
F9.20.051,424.00
F9.20.061,424.00
PVDF
L1
F9.20.071,608.00
F9.20.081,608.00
Panel Mount InstrumentDirect Mount Package Wall Mount Instrument
Sensor Electrical Class – IP68 (NEMA 6, 6P), supplied with 8 m (26 ft.) long cable, 22 AWG, 3 conductors.
L0
CPVCConfiguration Voltage L1 L0
PVDF
L1
Sensor Length
Body
O-Ring
Sensor Length
Body
O-Ring
F3.00.C IP68F3.00.C IP65
Panel Mount2 x 3.6 Volt
Battery
F9.20.P1.131,335.00
F9.20.P1.141,335.00
EPDM
Viton®
Wall Mount2 x 3.6 Volt
Battery
Instrument – F9.20Mounting Kit – F9.KC1
Sensor – F3.01.C.xx
Components
Instrument – F9.20Mounting Kit – F9.KP1
Sensor – F3.00.C.xx
Instrument – F9.20Mounting Kit – F9.KW1
Sensor – F3.00.C.xx
F9.20.W1.131,357.00
F9.20.W1.141,357.00
F9.20.P1.151,355.00
F9.20.P1.161,355.00
F9.20.W1.151,377.00
F9.20.W1.161,377.00
F9.20.P1.171,475.00
F9.20.P1.181,475.00
F9.20.W1.171,497.00
F9.20.W1.181,497.00
F9.20.P1.191,639.00
F9.20.P1.201,639.00
F9.20.W1.191,661.00
F9.20.W1.201,661.00
EPDM
Viton®
Panel Mount2 x 3.6 Volt
Battery
F9.20.P1.011,335.00
F9.20.P1.021,335.00
EPDM
Viton®
Wall Mount2 x 3.6 Volt
Battery
Components
Instrument – F9.20Mounting Kit – F9.KP1
Sensor – F3.00.C.xx
Instrument – F9.20Mounting Kit – F9.KW1
Sensor – F3.00.C.xx
F9.20.W1.011,357.00
F9.20.W1.021,357.00
F9.20.P1.031,355.00
F9.20.P1.041,355.00
F9.20.W1.031,377.00
F9.20.W1.041,377.00
F9.20.P1.051,475.00
F9.20.P1.061,475.00
F9.20.W1.051,497.00
F9.20.W1.061,497.00
F9.20.P1.071,639.00
F9.20.P1.081,639.00
F9.20.W1.071,661.00
F9.20.W1.081,661.00
EPDM
Viton®
14 Price List USF05-1 Consult Chemline Plastics for availability.Subject to change without notice.
Sensor Electrical Class – IP65 (NEMA 4, 4X), supplied with 4 pole cable plug for remote installation (cable is not supplied).
Packages
F9.20 Battery Powered Flow MonitorPackagesF9.20 Battery Powered Flow Monitor packages come complete with:
1. F9.20 Flow Monitor. See page 5.2. Instrument Mounting Kit. See page 5.3. Flow Sensor F3.01.C or F3.00.C. See page 3.
(Power supply provided by the flow monitor).
See pages noted for component descriptions and unit prices.
Installation fittings are required for these paddle wheel typesensors. See pages 20 and 21 for fittings and to determine sensorlength required (L0 or L1).
Displays: Flow Rate – 5 digitsResettable Total – 6 digitsNon-resettable Total – 10 digits
Outputs: NoneLEDs: None
Direct Mount2 x 3.6 Volt
Battery
Configuration Voltage
EPDM
Viton®
L0
F9.20.091,613.00
F9.20.101,613.00
316L SS
L1
F9.20.111,645.00
F9.20.121,645.00
Panel Mount InstrumentDirect Mount Package Wall Mount Instrument
Sensor Electrical Class – IP68 (NEMA 6, 6P), supplied with 8 m (26 ft.) long cable, 22 AWG, 3 conductors.
Configuration Voltage L0
316L SS
L1
Sensor Length
Body
O-Ring
Sensor Length
Body
O-Ring
F3.00.C IP68F3.00.C IP65
Panel Mount2 x 3.6 Volt
Battery
EPDM
Viton®
Wall Mount2 x 3.6 Volt
Battery
Instrument – F9.20Mounting Kit – F9.KC1
Sensor – F3.01.C.xx
Components
Instrument – F9.20Mounting Kit – F9.KP1
Sensor – F3.00.C.xx
Instrument – F9.20Mounting Kit – F9.KW1
Sensor – F3.00.C.xx
F9.20.P1.211,719.00
F9.20.P1.221,719.00
F9.20.W1.211,741.00
F9.20.W1.221,741.00
F9.20.P1.231,759.00
F9.20.P1.241,759.00
F9.20.W1.231,781.00
F9.20.W1.241,781.00
L0
F9.20.251,486.00
F9.20.261,486.00
Brass
L1
F9.20.271,634.00
F9.20.281,634.00
F9.20.P1.291,514.00
F9.20.P1.301,514.00
F9.20.W1.291,536.00
F9.20.W1.301,536.00
F9.20.P1.311,662.00
F9.20.P1.321,662.00
F9.20.W1.311,684.00
F9.20.W1.321,684.00
EPDM
Viton®
Panel Mount2 x 3.6 Volt
Battery
EPDM
Viton®
Wall Mount2 x 3.6 Volt
Battery
Components
Instrument – F9.20Mounting Kit – F9.KP1
Sensor – F3.00.C.xx
Instrument – F9.20Mounting Kit – F9.KW1
Sensor – F3.00.C.xx
F9.20.P1.091,719.00
F9.20.P1.101,719.00
F9.20.W1.091,741.00
F9.20.W1.101,741.00
F9.20.P1.111,759.00
F9.20.P1.121,759.00
F9.20.W1.111,781.00
F9.20.W1.121,781.00
L0
Brass
L1
F9.20.P1.251,514.00
F9.20.P1.261,514.00
F9.20.W1.251,536.00
F9.20.W1.261,536.00
F9.20.P1.271,662.00
F9.20.P1.281,662.00
F9.20.W1.271,684.00
F9.20.W1.281,684.00
EPDM
Viton®
Price List USF05-1 15 Consult Chemline Plastics for availability.Subject to change without notice.
Sensor Electrical Class – IP65 (NEMA 4, 4X), supplied with 4 pole cable plug for remote installation (cable is not supplied).
New
New
Packages
Panel Mount InstrumentDirect Mount Package Wall Mount Instrument
F9.50 Batch Controller Packages F9.50 Batch Controller packages come complete with:
1. F9.50 Batch Controller. See page 5.2. Instrument Mounting Kit. See page 5.3. Flow Sensor F3.01.H or F3.00.H. See page 2.
(Power supply provided by the flow monitor).
See pages noted for component descriptions and unit prices.
Installation fittings are required for these paddle wheel typesensors. See pages 20 and 21 for fittings and to determine sensorlength required (L0 or L1).
Displays: Batch in Progress – 6 digitsFlow Rate – 5 digitsResettable Total – 6 digitsNon-Resettable Total – 10 digits
Outputs: 4 to 20 mA 3/4 wire 1 Open collector2 SPDT relays
LEDs: 3
L0
CPVCConfiguration Required Voltage L1 L0
PVDF
L1
Direct Mount12 – 24 VDC
Panel Mount12 – 24 VDC
L0
F9.50.011,180.00
F9.50.021,180.00
F9.50.P1.011,210.00
F9.50.P1.021,210.00
CPVCConfiguration Required Voltage
EPDM
Viton®
EPDM
Viton®
Wall Mount 112 – 24 VDC
F9.50.W1.011,232.00
F9.50.W1.021,232.00
L1
F9.50.031,197.00
F9.50.041,197.00
F9.50.P1.031,230.00
F9.50.P1.041,230.00
F9.50.W1.031,252.00
F9.50.W1.041,252.00
L0
F9.50.051,299.00
F9.50.061,299.00
F9.50.P1.051,350.00
F9.50.P1.061,350.00
PVDF
F9.50.W1.051,372.00
F9.50.W1.061,372.00
L1
F9.50.071,483.00
F9.50.081,483.00
F9.50.P1.071,514.00
F9.50.P1.081,514.00
F9.50.W1.071,536.00
F9.50.W1.081,536.00
Wall Mount 2110 – 230 VAC
Components
Instrument – F9.50Mounting Kit – F9.KP1
Sensor – F3.00.H.xx
Instrument – F9.50Mounting Kit – F9.KW1
Sensor – F3.00.H.xx
Instrument – F9.50Mounting Kit – F9.KW2
Sensor – F3.00.H.xx
F9.50.W2.011,306.00
F9.50.W2.021,306.00
EPDM
Viton®
F9.50.W2.031,326.00
F9.50.W2.041,326.00
F9.50.W2.051,466.00
F9.50.W2.061,466.00
F9.50.W2.071,610.00
F9.50.W2.081,610.00
EPDM
Viton®
Sensor Electrical Class – IP68 (NEMA 6, 6P), supplied with 8 m (26 ft.) long cable, 22 AWG, 3 conductors.
Sensor Length
Body
O-Ring
Sensor Length
Body
O-Ring
F3.00.H IP68F3.00.H IP65
Panel Mount12 – 24 VDC
Wall Mount 112 – 24 VDC
F9.50.P1.131,210.00
F9.50.P1.141,210.00
F9.50.W1.131,232.00
F9.50.W1.141,232.00
EPDM
Viton®
EPDM
Viton®
Wall Mount 2110 – 230 VAC
Instrument – F9.50Mounting Kit – F9.KC1
Sensor – F3.01.H.xx
Components
Instrument – F9.50Mounting Kit – F9.KP1
Sensor – F3.00.H.xx
Instrument – F9.50Mounting Kit – F9.KW1
Sensor – F3.00.H.xx
Instrument – F9.50Mounting Kit – F9.KW2
Sensor – F3.00.H.xx
F9.50.W2.131,306.00
F9.50.W2.141,306.00
F9.50.P1.151,230.00
F9.50.P1.161,230.00
F9.50.W1.151,252.00
F9.50.W1.161,252.00
F9.50.W2.151,326.00
F9.50.W2.161,326.00
F9.50.P1.171,350.00
F9.50.P1.181,350.00
F9.50.W1.171,372.00
F9.50.W1.181,372.00
F9.50.W2.171,466.00
F9.50.W2.181,466.00
F9.50.P1.191,514.00
F9.50.P1.201,514.00
F9.50.W1.191,536.00
F9.50.W1.201,536.00
F9.50.W2.191,610.00
F9.50.W2.201,610.00
EPDM
Viton®
16 Price List USF05-1 Consult Chemline Plastics for availability.Subject to change without notice.
Sensor Electrical Class – IP65 (NEMA 4, 4X), supplied with 4 pole cable plug for remote installation (cable is not supplied).
Packages
Panel Mount InstrumentDirect Mount Package Wall Mount Instrument
F9.50 Batch Controller Packages F9.50 Batch Controller packages come complete with:
1. F9.50 Batch Controller. See page 5.2. Instrument Mounting Kit. See page 5.3. Flow Sensor F3.01.H or F3.00.H. See page 2.
(Power supply provided by the flow monitor).
See pages noted for component descriptions and unit prices.
Installation fittings are required for these paddle wheel typesensors. See pages 20 and 21 for fittings and to determine sensorlength required (L0 or L1).
Displays: Batch in Progress – 6 digitsFlow Rate – 5 digitsResettable Total – 6 digitsNon-Resettable Total – 10 digits
Outputs: 4 to 20 mA 3/4 wire 1 Open collector2 SPDT relays
LEDs: 3
Configuration Required Voltage L0
316L SS
L1
Direct Mount12 – 24 VDC
Panel Mount12 – 24 VDC
Configuration Required Voltage
EPDM
Viton®
EPDM
Viton®
Wall Mount 112 – 24 VDC
L0
F9.50.091,488.00
F9.50.101,488.00
F9.50.P1.091,594.00
F9.50.P1.101,594.00
316L SS
F9.50.W1.091,616.00
F9.50.W1.101,616.00
L1
F9.50.111,520.00
F9.50.121,520.00
F9.50.P1.111,634.00
F9.50.P1.121,634.00
Wall Mount 2110 – 230 VAC
Components
Instrument – F9.50Mounting Kit – F9.KP1
Sensor – F3.00.H.xx
Instrument – F9.50Mounting Kit – F9.KW1
Sensor – F3.00.H.xx
Instrument – F9.50Mounting Kit – F9.KW2
Sensor – F3.00.H.xx
EPDM
Viton®
F9.50.W2.091,690.00
F9.50.W2.101,690.00
F9.50.W2.111,730.00
F9.50.W2.121,730.00
F9.50.W1.111,656.00
F9.50.W1.121,656.00
L0
Brass
L1
F9.50.P1.251,389.00
F9.50.P1.261,389.00
F9.50.W1.251,411.00
F9.50.W1.261,411.00
F9.50.P1.271,537.00
F9.50.P1.281,537.00
F9.50.W2.251,485.00
F9.50.W2.261,485.00
F9.50.W2.271,633.00
F9.50.W2.281,633.00
F9.50.W1.271,559.00
F9.50.W1.281,559.00
EPDM
Viton®
Sensor Electrical Class – IP68 (NEMA 6, 6P), supplied with 8 m (26 ft.) long cable, 22 AWG, 3 conductors.
Sensor Length
Body
O-Ring
Sensor Length
Body
O-Ring
F3.00.H IP68F3.00.H IP65
Panel Mount12 – 24 VDC
Wall Mount 112 – 24 VDC
EPDM
Viton®
EPDM
Viton®
Wall Mount 2110 – 230 VAC
Instrument – F9.50Mounting Kit – F9.KC1
Sensor – F3.01.H.xx
Components
Instrument – F9.50Mounting Kit – F9.KP1
Sensor – F3.00.H.xx
Instrument – F9.50Mounting Kit – F9.KW1
Sensor – F3.00.H.xx
Instrument – F9.50Mounting Kit – F9.KW2
Sensor – F3.00.H.xx
F9.50.P1.211,594.00
F9.50.P1.221,594.00
F9.50.W1.211,616.00
F9.50.W1.221,616.00
F9.50.W2.211,690.00
F9.50.W2.221,690.00
F9.50.P1.231,634.00
F9.50.P1.241,634.00
F9.50.W1.231,656.00
F9.50.W1.241,656.00
F9.50.W2.231,730.00
F9.50.W2.241,730.00
L0
F9.50.251,361.00
F9.50.261,361.00
Brass
L1
F9.50.271,509.00
F9.50.281,509.00
F9.50.P1.291,389.00
F9.50.P1.301,389.00
F9.50.W1.291,411.00
F9.50.W1.301,411.00
F9.50.W2.291,485.00
F9.50.W2.301,485.00
F9.50.P1.311,537.00
F9.50.P1.321,537.00
F9.50.W1.311,559.00
F9.50.W1.321,559.00
F9.50.W2.311,633.00
F9.50.W2.321,633.00
EPDM
Viton®
Price List USF05-1 17 Consult Chemline Plastics for availability.Subject to change without notice.
Sensor Electrical Class – IP65 (NEMA 4, 4X), supplied with 4 pole cable plug for remote installation (cable is not supplied).
New
New
Packages
Panel Mount Instrument Wall Mount Instrument
ULF Sensor
ULF9.0x Monitor/Transmitter PackagesULF9.0x Monitor/Transmitter packages come complete with:
1. F9.00, F9.01 or F9.02 Flow Monitor and Transmitter. See page 5.2. Instrument Mounting Kit. See page 5.3. Ultra Low Flow Sensor ULF.H or ULF.R. See page 4.
(Power supply provided by the flow monitor).
See pages noted for component descriptions and unit prices.
Sensors have male threaded in-line connections,1/4" BSP.
Displays: Flow Rate – 5 digits,Resettable Total – 6 digitsNon-resettable Total – 10 digits
† POM = "Polyoxymethylene". * ECTFE is also referred to as "Halar®".
18 Price List USF05-1 Consult Chemline Plastics for availability.Subject to change without notice.
Configuration Required Voltage Item No.
1.5 – 100 l/h
Price
Panel Mount12 – 24 VDC
Wall Mount 112 – 24 VDC
Components Body / O-Rings
Instrument – F9.00Mounting Kit – F9.KP1
Sensor – ULF.R
Instrument – F9.00Mounting Kit – F9.KW1
Sensor – ULF.R
Wall Mount 2110 – 230 VAC
Instrument – F9.00Mounting Kit – F9.KW2
Sensor – ULF.R
Item No.
6 – 250 l/h
Price
ULF9.00 Outputs: 4 to 20 mA 2 wire, 1 open collector LEDs: 1
889.00
1,111.00
1,346.00
911.00
1,133.00
1,368.00
985.00
1,207.00
1,442.00
889.00
1,111.00
1,346.00
911.00
1,133.00
1,368.00
985.00
1,207.00
1,442.00
ULF9.00.P1.01.0
ULF9.00.P1.01.2
ULF9.00.P1.01.3
ULF9.00.W1.01.0
ULF9.00.W1.01.2
ULF9.00.W1.01.3
ULF9.00.W2.01.0
ULF9.00.W2.01.2
ULF9.00.W2.01.3
ULF9.00.P1.03.0
ULF9.00.P1.03.2
ULF9.00.P1.03.3
ULF9.00.W1.03.0
ULF9.00.W1.03.2
ULF9.00.W1.03.3
ULF9.00.W2.03.0
ULF9.00.W2.03.2
ULF9.00.W2.03.3
Configuration Required Voltage Item No.
1.5 – 100 l/h
Price
Panel Mount12 – 24 VDC
Wall Mount 112 – 24 VDC
Components Body / O-Rings
Instrument – F9.01Mounting Kit – F9.KP1
Sensor – ULF.H
Instrument – F9.01Mounting Kit – F9.KW1
Sensor – ULF.H
Wall Mount 2110 – 230 VAC
Instrument – F9.01Mounting Kit – F9.KW2
Sensor – ULF.H
Item No.
6 – 250 l/h
Price
ULF9.01 Outputs: 4 to 20 mA 3/4 wire, 3 open collectors LEDs: 3
900.00
1,165.00
1,415.00
922.00
1,187.00
1,437.00
996.00
1,261.00
1,511.00
900.00
1,165.00
1,415.00
922.00
1,187.00
1,437.00
996.00
1,261.00
1,511.00
ULF9.01.P1.01.0
ULF9.01.P1.01.2
ULF9.01.P1.01.3
ULF9.01.W1.01.0
ULF9.01.W1.01.2
ULF9.01.W1.01.3
ULF9.01.W2.01.0
ULF9.01.W2.01.2
ULF9.01.W2.01.3
POM† / Viton®
ECTFE* / Viton®
ECTFE* / Kalrez®
POM† / Viton®
ECTFE* / Viton®
ECTFE* / Kalrez®
POM† / Viton®
ECTFE* / Viton®
ECTFE* / Kalrez®
POM† / Viton®
ECTFE* / Viton®
ECTFE* / Kalrez®
POM† / Viton®
ECTFE* / Viton®
ECTFE* / Kalrez®
POM† / Viton®
ECTFE* / Viton®
ECTFE* / Kalrez®
ULF9.01.P1.03.0
ULF9.01.P1.03.2
ULF9.01.P1.03.3
ULF9.01.W1.03.0
ULF9.01.W1.03.2
ULF9.01.W1.03.3
ULF9.01.W2.03.0
ULF9.01.W2.03.2
ULF9.01.W2.03.3
Configuration Required Voltage Item No.
1.5 – 100 l/h
Price
Panel Mount12 – 24 VDC
Wall Mount 112 – 24 VDC
Components Body / O-Rings
Instrument – F9.02Mounting Kit – F9.KP1
Sensor – ULF.H
Instrument – F9.02Mounting Kit – F9.KW1
Sensor – ULF.H
Wall Mount 2110 – 230 VAC
Instrument – F9.02Mounting Kit – F9.KW2
Sensor – ULF.H
Item No.
6 – 250 l/h
Price
ULF9.02 Outputs: 4 to 20 mA 3/4 wire, 1 open collector and 2 SPDT relays LEDs: 3
912.00
1,177.00
1,427.00
934.00
1,199.00
1,449.00
1,008.00
1,273.00
1,523.00
912.00
1,177.00
1,427.00
934.00
1,199.00
1,449.00
1,008.00
1,273.00
1,523.00
ULF9.02.P1.01.0
ULF9.02.P1.01.2
ULF9.02.P1.01.3
ULF9.02.W1.01.0
ULF9.02.W1.01.2
ULF9.02.W1.01.3
ULF9.02.W2.01.0
ULF9.02.W2.01.2
ULF9.02.W2.01.3
ULF9.02.P1.03.0
ULF9.02.P1.03.2
ULF9.02.P1.03.3
ULF9.02.W1.03.0
ULF9.02.W1.03.2
ULF9.02.W1.03.3
ULF9.02.W2.03.0
ULF9.02.W2.03.2
ULF9.02.W2.03.3
POM† / Viton®
ECTFE* / Viton®
ECTFE* / Kalrez®
POM† / Viton®
ECTFE* / Viton®
ECTFE* / Kalrez®
POM† / Viton®
ECTFE* / Viton®
ECTFE* / Kalrez®
Packages
ULF9.50 Batch Controller PackagesULF9.50 Batch Controller packages come complete with:
1. F9.50 Batch Controller. See page 5.2. Instrument Mounting Kit. See page 5.3. Ultra Low Flow Sensor ULF.H. See page 4.
(Power supply provided by the flow monitor).
See pages noted for component descriptions and unit prices.
Sensors have male threaded in-line connections,1/4" BSP.
Displays: Batch in Progress – 6 digitsFlow Rate – 5 digitsResettable Total – 6 digitsNon-Resettable Total – 10 digits
Panel Mount Instrument Wall Mount Instrument
ULF9.20 Battery Powered FlowMonitor PackagesULF9.20 Battery Powered Flow Monitor packages come complete with:
1. F9.20 Battery Powered Flow Monitor. See page 5.2. Instrument Mounting Kit. See page 5.3. Ultra Low Flow Sensor ULF.R. See page 4.
See pages noted for component descriptions and unit prices.
Sensors have male threaded in-line connections,1/4" BSP.
Displays: Flow Rate – 5 digitsResettable Total – 6 digitsNon-resettable Total – 10 digits
Outputs: NoneLEDs: None
ULF Sensor
Panel Mount Instrument Wall Mount Instrument
ULF Sensor
Outputs: 4 to 20 mA 3/4 wire 1 Open collector2 SPDT relays
LEDs: 3
Price List USF05-1 19 Consult Chemline Plastics for availability.Subject to change without notice.
Configuration Voltage Item No.
1.5 – 100 l/h
Price
Panel Mount2 x 3.6 Volt
Battery
Wall Mount2 x 3.6 Volt
Battery
Components Body / O-Rings
Instrument – F9.20Mounting Kit – F9.KP1
Sensor – ULF.R
Instrument – F9.20Mounting Kit – F9.KW1
Sensor – ULF.R
Item No.
6 – 250 l/h
Price
ULF9.20
† POM = "Polyoxymethylene". * ECTFE is also referred to as "Halar®".
Configuration Required Voltage Item No.
1.5 – 100 l/h
Price
Panel Mount12 – 24 VDC
Wall Mount 112 – 24 VDC
Components Body / O-Rings
Instrument – F9.50Mounting Kit – F9.KP1
Sensor – ULF.H
Instrument – F9.50Mounting Kit – F9.KW1
Sensor – ULF.H
Wall Mount 2110 – 230 VAC
Instrument – F9.50Mounting Kit – F9.KW2
Sensor – ULF.H
Item No.
6 – 250 l/h
Price
ULF9.50
† POM = "Polyoxymethylene". * ECTFE is also referred to as "Halar®".
975.00
1,240.00
1,490.00
997.00
1,262.00
1,512.00
1,071.00
1,336.00
1,586.00
975.00
1,240.00
1,490.00
997.00
1,262.00
1,512.00
1,071.00
1,336.00
1,586.00
ULF9.50.P1.01.0
ULF9.50.P1.01.2
ULF9.50.P1.01.3
ULF9.50.W1.01.0
ULF9.50.W1.01.2
ULF9.50.W1.01.3
ULF9.50.W2.01.0
ULF9.50.W2.01.2
ULF9.50.W2.01.3
ULF9.50.P1.03.0
ULF9.50.P1.03.2
ULF9.50.P1.03.3
ULF9.50.W1.03.0
ULF9.50.W1.03.2
ULF9.50.W1.03.3
ULF9.50.W2.03.0
ULF9.50.W2.03.2
ULF9.50.W2.03.3
POM† / Viton®
ECTFE* / Viton®
ECTFE* / Kalrez®
POM† / Viton®
ECTFE* / Viton®
ECTFE* / Kalrez®
POM† / Viton®
ECTFE* / Viton®
ECTFE* / Kalrez®
POM† / Viton®
ECTFE* / Viton®
ECTFE* / Kalrez®
POM† / Viton®
ECTFE* / Viton®
ECTFE* / Kalrez®
ULF9.20.P1.01.0
ULF9.20.P1.01.2
ULF9.20.P1.01.3
ULF9.20.W1.01.0
ULF9.20.W1.01.2
ULF9.20.W1.01.3
1,117.00
1,339.00
1,574.00
1,139.00
1,361.00
1,596.00
1,117.00
1,339.00
1,574.00
1,139.00
1,361.00
1,596.00
ULF9.20.P1.03.0
ULF9.20.P1.03.2
ULF9.20.P1.03.3
ULF9.20.W1.03.0
ULF9.20.W1.03.2
ULF9.20.W1.03.3
Installation Fittings
PriceItem No.SensorLength
MaterialsSaddle Insert Seal
PipeSize
TeesStandard elastomer seals are EPDM or Viton®. Other materials are available. PVC ends are ANSI socket. PP tees are female NPT and PVDFtees have DIN socket ends. Other materials are available including PP and PVDF with butt fusion ends (B). CPVC Tees are available.
2" L0 CPVC CPVC EPDM SACC020E 136.002-1/2" L0 CPVC CPVC EPDM SACC025E 178.00
3" L0 CPVC CPVC EPDM SACC030E 178.004" L0 CPVC CPVC EPDM SACC040E 194.005" L1 CPVC CPVC EPDM SACC050E 215.006" L1 CPVC CPVC EPDM SACC060E 270.008" L1 CPVC CPVC EPDM SACC080E 279.0010" L1 PP CPVC Nitrile SABC100N 336.0012" L1 PP CPVC Nitrile SABC120N 336.00
Bolt-On Saddles
Installation Fittings for Paddle Wheel Sensors
Materials – Body / O-Rings / End Connections
PVC / EPDM / Socket PP / EPDM / Threaded PVDF / Viton® / Socket WeldPrice
106.00
106.00
133.00
133.00
148.00
Item No.
TEA005ES
TEA007ES
TEA010ES
TEA012ES
TEA015ES
SensorLength
L0
L0
L0
L0
L0
Item No.
TEB005ET
TEB007ET
TEB010ET
TEB012ET
TEB015ET
Size
1/2"
3/4"
1"
1-1/4"
1-1/2"
Item No.
TEK005VS
TEK007VS
TEK010VS
TEK012VS
TEK015VS
Price
194.00
194.00
206.00
206.00
233.00
Price
125.00
125.00
161.00
161.00
183.00
Viton® seals are available for the same price. Substitute V instead of E in the Item Number. PVDF inserts are also available. P.O.A.
Sensors with Viton® or EPDM seals are the same price. Substitute V instead of E in the Item Number. PVC and PP are standard with EPDM,PVDF with Viton®.
Tee Bolt-On Saddle
Metal Strap-On Saddles All saddles are cast iron and stainless steel body with Nitrile o-ring.
PriceMin. Max. Pipe O.D. Range Pipe O.D. Range
Item No.SensorLength
SensorLength
PipeSize
PipeSize
3" L0 3.5" 4.1" MSS030N 190.004" L0 4.4" 5.0" MSS040N 195.005" L0 5.5" 6.1" MSS050N 250.006" L0 6.6" 7.2" MSS060N 265.008" L1 8.6" 9.6" MSS080N 276.00
PriceMin. Max. Item No.
10" L1 10.7" 11.6" MSS100N 293.0012" L1 12.7" 13.9" MSS120N 311.0014" L1 14.0" 16.3" MSS140N 337.0016" L1 16.0" 18.6" MSS160N 382.0018" L1 18.0" 21.0" MSS180N 465.00
Wafer Fittings Standard elastomer seals are EPDM or Viton®. Bodies are either PVC or PPG (glass reinforced polypropylene).
Item No.Seals
Materials – Body
PVC PPGPipeSize
SensorLength
L010"
12" L0
Price Item No. Price
Wafer FittingMetal Strap-On Saddle
EPDMViton®
EPDMViton®
WFA100EWFA100VWFA120EWFA120V
478.001,411.00
546.001,712.00
WFB100EWFB100VWFB120EWFB120V
560.001,492.00
667.001,831.00
20 Price List USF05-1 Consult Chemline Plastics for availability.Subject to change without notice.
Installation Fittings
PlugsPlugs are used to cap off installation tees or saddles after a sensor isremoved for relocation, repair or pipeline maintenance.
94.0094.00
156.00
Item No.PLUGAEPLUGBEPLUGKV
PriceBody / O-RingsPVC / EPDMPP / EPDM
PVDF / Viton®
316L SS Threaded TeesWith BSP female threaded connections.
Price
298.00
298.00
323.00
Item No.
TES007T–BSP
TES010T–BSP
TES012T–BSP
Sensor Length
L0
L0
L0
Size
3/4"
1"
1-1/4"
Installation Fittings for Paddle Wheel Sensors
Hot-Tap SS Weld-On Adaptor
316L SS Threaded Tee
Weld-On Adaptors
Item No. PricePipe Size Sensor Length Material
Other Plastic Weld-On Adaptors are available in any material to match the piping. Consult Chemline.
Hot-Tap Weld-On Adaptors for SS Sensors / Brass Installation Valve
16" Minimum 316L Stainless Steel 2" BSP Connections WAIXHT 159.002" Brass Installation Valve Brass F1.SP3 119.00with BSP Connections
Item No. PricePipe Size Material
Hot-Tap Strap-On Saddle
Installation Fittings for F111 Hot-Tap SensorsHot-Tap Metal Strap-On Saddles for SS SensorsAll saddles are cast iron and stainless steel body with Nitrileo-ring, complete with 2" brass valve with female BSP Connection.
PriceMin. Max. Item No.Pipe O.D. Range Pipe O.D. RangePipe
SizePipeSize
2" 2.4" 2.7" MSS020N–HT * 190.003" 3.5" 4.1" MSS030N–HT 190.004" 4.4" 5.0" MSS040N–HT 195.005" 5.5" 6.1" MSS050N–HT 250.006" 6.6" 7.2" MSS060N–HT 265.008" 8.6" 9.6" MSS080N–HT 276.00
PriceMin. Max. Item No.
10" 10.7" 11.6" MSS100N–HT 293.0012" 12.7" 13.9" MSS120N–HT 311.0014" 14.0" 16.3" MSS140N–HT 337.0016" 16.0" 18.6" MSS160N–HT 382.0018" 18.0" 21.0" MSS180N–HT 465.00
Weld-On Adaptor
1-1/2" – 8" L0 316L Stainless Steel WOSS–L0 159.00PE WOPE–L0 54.60
10" – 24" L1 316L Stainless Steel WOSS–L1 180.00PE WOPE–L1 117.00
Price List USF05-1 21 Consult Chemline Plastics for availability.Subject to change without notice.
* For Brass Hot-Tap Sensors only.
Type F3.60– Electromagnetic Flow TransmitterOutput signal is 4 to 20 mA 3/4 wire. Parts in contact with liquidare sensor body, and Hastelloy C electrodes. The signal is normallyfed to a F9.01, F9.02, F9.03 or F9.50 Instrument. See page 5.
Item No.Power SupplyPipe Material PriceSensor Body / SealPipe Size
PriceSeals†† Item No.SaddleCPVC Insert PVDF Insert
Materials
PipeSize
Bolt-On Saddles for Type F3.60 Flow TransmittersAll saddles are CPVC with CPVC or PVDF inserts.
Weld-On Adaptors for Type F3.60 Flow Transmitters
PriceItem No.3" CPVC EPDM SACC030E–M 258.00 SACK030E–M 309.004" CPVC EPDM SACC040E–M 267.00 SACK040E–M 323.005" CPVC EPDM SACC050E–M 304.00 SACK050E–M 330.006" CPVC EPDM SACC060E–M 309.00 SACK060E–M 387.008" CPVC EPDM SACC080E–M 340.00 SACK080E–M 422.00
Flow UnitsConversion Chart
† Values based on water at 20ºC.
m3/hr
litres/hr
USGPM
ImpGPM
ft3/min
lbs/min†
kgs/min†
FromTo
m3/hr
1
0.001
0.2271
0.2728
1.6990
0.0272
.06
litres/hr
1000
1
227.12
272.77
1699
27.2156
60
USGPM
4.4029
.004403
1
1.2009
7.4806
0.1198
0.2642
ImpGPM
3.6662
.003666
0.8327
1
6.2289
0.0998
.2200
ft3/min
0.5886
.000589
0.1337
0.1605
1
0.0160
.0353
lbs/min†
36.7437
0.0367
8.3454
10.0224
62.4282
1
2.2046
kgs/min†
16.6667
0.0167
3.7854
4.5461
28.3170
0.4536
1
2"– 16" Metal or Plastic SS – PVDF / EPDM 230 VAC F3.60M.01 2,844.002"– 16" Metal or Plastic SS – PVDF / EPDM 110 VAC F3.60M.02 2,844.002"– 16" Metal or Plastic SS – PVDF / EPDM 24 VAC F3.60M.05 2,844.00
F3.60
Electromagnetic
Bolt-On Saddle
22 Price List USF05-1 Consult Chemline Plastics for availability.Subject to change without notice.
Item No.Material PricePipe Size
2"– 16" 316 SS WAIX360 234.00
Weld-On Adaptor Tee
Installation Tees for Type F3.60 Flow Transmitters, TU SocketItem No.Material PricePipe Size
2" PVC TEA020–M 312.002-1/2" PVC TEA025–M P.O.A.
Flow MeterSelection Questionnaire
Questionnaire
Reference Notes
1. Digiflow® FlowX3 flow meters measure liquids only. No air bubbles should be present and the pipe must always be full.
2. Check chemical resistance of the fluid to verify if wetted parts are acceptable.
3. Check that the service is within the pressure/temperature rating of installation fitting.
4. Viscosity range is 0.5 to 20 cSt (centistokes). Factor calibrationis required if outside this range, up to 40 cSt maximum. Maximum viscosity for Oval Gear flow sensor is 1,000 cP. Insertion electromagnetic flow transmitters have no viscositylimitations. See Units of Viscosity below.
5. Maximum percentage solids content for paddle wheel sensors is 10%, with particles not to exceed 0.5 mm in length or diameter (0% solids for ULF flow sensors). The insertion typeelectromagnetic flow transmitters can handle homogeneoussolids easily. Particle size is not an issue.
6. Paddle wheel flow meters cannot be used on services containing ferrous particles i.e., those which will be attracted to the magnetic rotor blades. The insertion type electromagnetic flow transmitters is only sensitive to metallicparticles if they are magnetic.
7. Electromagnetic flow transmitters require liquid to haveminimum conductivity at 20 microSiemens.
8. For accurate flow measurement there must be a developedturbulent velocity profile at the sensor location. This requires astraight run pipe with a minimum number of pipe diametersdistance upstream and downstream of the flow sensor. Thesedistances depend on the type of piping element (i.e. valves, elbows, reducers etc.) causing the disturbance. See page 36.
9. Hall Effect signals may be transmitted up to 300 meters(984 ft.) without the need for conditioning whereas Coil orReed Effect signals may be transmitted up to 16 m (52.5 ft.) without conditioning. Coil Effect sensors are normally used with the battery powered flow monitor.
Units of ViscosityAbsolute Viscosity (m): 1 poise (P) = 1 dyne = 1 gm
cm2 cm ● sec.1 centipoise (cP) = 0.01 poiseViscosity of water at 20oC is 1.002 cP
Kinematic Viscosity (n) = Absolute ViscosityDensity of Fluid
1 stoke (St) = 1 m2
sec.1 centistoke (cSt) = 0.01 stoke
Viscosity is temperature dependent. Liquid viscosities drop withincreased temperature.
Concentration:
Viscosity:
Fluid:
Temperature: oC
psi
cSt
%
Units:/
mm dia.
%
(Notes 1, 2)
(Note 2)
(Notes 2, 3)
(Note 3)
(Note 4)
(Note 5)
(Note 5)
(Note 6)
(Note 7)
Pressure:
Ferrous Particles in Fluid?:
Electromagnetic flow meters only:conductivity of fluid greaterthan 20 microSiemens?:
Particle Size:
❏ Yes ❏ No
❏ Yes ❏ No
Maximum Solids:
Maximum/minimum measured flow rate:
Pipe Size:
Sensor Body: ❏ CPVC ❏ 316L SS❏ PVDF ❏ Brass
Sensor O-Rings: ❏ EPDM ❏ Viton®
❏ Other
Installation Fittings: ❏ Tee ❏ Saddle❏ Weld-On Adaptor
Power Supply Available:
Distance of straight pipe upstream/downstream
of flow sensor: /
Type of piping element upstream/downstreamof flow sensor (i.e. valve, elbow, reducer, etc.):
/
Maximum distance from flow sensor to remote
instrument:
Pipe Material:
(Note 8)
(Note 9)
(Note 8)
Price List USF05-1 23Consult Chemline Plastics for availability.Subject to change without notice.
Instruments
Flow Sensors
Installation Fittings
Type F3.00Remote NEMA 6Flow Sensors
Type F3.00Remote NEMA 4Flow Sensors
Type F3.01Direct MountNEMA 6Flow Sensors
ULF.H and ULF.RUltra Low FlowSensors
Type F3.30 Blind Transmitters
Type ULF3.30 Ultra Low FlowBlind Transmitters
Type F3.15AdjustableFlow Switches
Type ULF3.15Adjustable UltraLow Flow Switches
• Tees
• Bolt-On Saddles
• Metal Strap-On Saddles
• Wafer Fittings
• Weld-On Adaptors
• Plugs
Type F3.60ElectromagneticFlow Transmitters
Type F9.00, F9.01, F9.02 & F9.03Flow Monitor/Transmitters
Type F9.50Batch Controller
Type F9.20Battery Powered Flow Monitor
Type F3.05No-FlowSwitches
Product Line
Price List USF05-1 24
55 Guardsman Road, Thornhill, Ontario, Canada, L3T 6L2Tel: 905-889-7890 info@chemline.comFax: 905-889-8553 www.chemline.com
Your Pipeline To Quality Valves, Piping, Flow Meters and Controls
Type F111Hot Tap FlowSensors
Recommended