Solutions for Complex Sites - Alabama · •Profile Methods . HPT Permeability Testing . Average...

Preview:

Citation preview

Solutions for Complex Sites

Brad Carlson Cascade Technical Services

2

The Main Idea

3

Moving On From Monitoring Wells

• Monitoring Wells (MWs) yield depth-integrated, flow-weighted averaged data, with no vertical distribution of contaminants in the screened interval.

• Monitoring wells are holes in the ground that can lie. • MWs and 5 foot soil cores do not define the small

scale heterogeneities controlling contaminant transport.

4

Real-Time Measurement Systems

The High Resolution Tools for Site Characterization

Real-Time Decision Making and Information Sharing

5

HRSC System Setup

Three components:

• -DPT/Probe rig

• -Tool String

• -Data collection equipment

Setup is similar to all real time measurement systems…

6

7

Electrical Conductivity EC Probe

8

The (MIP) Membrane Interface Probe System

9

The (MIP) Membrane Interface Probe System

•Screening Tool with semi-quantitative capabilities •Lab grade Detectors

• PID (BTEX) • ECD (CVOC’s) • XSD (CVOC’s) • FID

•Standard Practice ASTM Method D7352-07

FID

PID

ECD

10

Example MIP Log

11

Leogane,Haiti

Permeability ?

12

•Point Methods

•Profile Methods

HPT Permeability Testing

Average Data CPT SLUG

Specific Data HPT Waterloo APS

13

HPT Permeability Testing

14

HPT - Average Path versus Actual Path

Permeability Average

Point Method

Permeability Actual

Profile Methods

15

• Advance probe at constant rate

• Inject water at low flow rate

• Measure formation pressure response

2 cm/sec

The Hydraulic Profiling Tool (HPT) System

16 EC HPT Press Flow Corr HPT

Pressure Est K Abs Hydro

Pressure

Depth to GW

HPT Log

17

Dissipation – Static Water Level

8.08ft

8.02ft

18

MiHPT – “Your Can Run But You Can’t Hide”

• Providing the Whole Picture – Lithology: Electrical Conductivity

(EC) – VOC Mass: Membrane Interface

Probe (MIP) – Hydraulic Conductivity: Hydraulic

Profiling Tool (HPT) • 3 Tools – One Boring

19

MiHPT LOG

Storage

Transport

20

Cone Penetrometer Testing - CPT

21

CPT log

Sleeve Friction

Tip Pressure Lithology

Description

Friction Ratio

Pore Pressure

22

The UVOST System Ultraviolet Optical Screening Tool

23

Potential LIF Characterization Sites

• Leaking Underground Storage Tanks

• Pipelines

• Refineries

• Fueling Areas

• Automobile Service Locations

• Lagoons and Waste Ponds

24

NAPL concentration

25

The UVOST/LIF System

26 26

Fortunately all PAH non-aqueous phase liquids or NAPLs Fluoresce

short UV

long UV

kero

sene

ga

solin

e di

esel

oi

l

PAH fluorescence is a way to detect them by their “glow”

27

Example of Fluorescence

28

Each Aliphatic Solvent yield a fairly unique wavelength/time matrix (WTM)

Diesel

Jet

Motor O

il

Gas

Laser Induced Fluorescence (LIF) Concepts

29

UVOST/LIF Logs

30

31

HRSC High Resolution Site Characterization

State-of-the art analysis and visualization. Targeted Injection Plans

32

Evolution of HRSC 3D Imaged Source Area – PID > 1 x 106 microvolts

33

MVS – HRSC Integration • Conceptual

Site Model (CSM) development Well Screen Zones

34

HRSC Injection Planning

35

The Main Idea

36

Questions

Recommended