View
17
Download
19
Category
Preview:
Citation preview
Standard Construction Details
C
Burgh Rd Industrial Estate, Carlisle, Cumbria. CA2 7NA.
Tel 01228 640850 Fax 01228 640851
Window / Door Details (Aircrete)
(Full Fill)
SCHEDULE OF DRAWINGS
DWG. No. DescriptionRev:
AWDD - FF - 01
AWDD - FF - 02
AWDD - FF - 03
AWDD - FF - 04
AWDD - FF - 05
AWDD - FF - 06
AWDD - FF - 07
AWDD - FF - 08
AWDD - FF - 09
AWDD - FF - 10
AWDD - FF - 12
AWDD - FF - 13
AWDD - FF - 14
AWDD - FF - 15
AWDD - FF - 16
AWDD - FF - 17
AWDD - FF - 18
AWDD - FF - 19
AWDD - FF - 20
AWDD - FF - 21
AWDD - FF - 23
AWDD - FF - 24
AWDD - FF - 25
AWDD - FF - 26
AWDD - FF - 27
WINDOW IN BRICKWORK WITH CONCRETE HEAD - HEAD, CILL AND JAMB DETAILS
WINDOW IN RENDER WITH CONCRETE SURROUNDS - HEAD, CILL AND JAMB DETAILS
WINDOW IN BRICKWORK WITH FEATURE BAND HEAD - HEAD, CILL AND JAMB DETAILS
WINDOW IN 1/2 BRICK 1/2 RENDER WITH FEATURE BAND HEAD - HEAD, CILL AND JAMB DETAILS
WINDOW IN 1/2 BRICK 1/2 RENDER WITH ARCHED HEAD - HEAD, CILL AND JAMB DETAILS
WINDOW IN BRICKWORK WITH ARCHED HEAD - HEAD, CILL AND JAMB DETAILS
WINDOW IN RENDER WITH ARCHED HEAD - HEAD, CILL AND JAMB DETAILS
WINDOW IN RENDER WITH FEATURE BAND HEAD - HEAD, CILL AND JAMB DETAILS
WINDOW IN BRICKWORK WITH CONCRETE SURROUNDS - HEAD, CILL AND JAMB DETAILS
DOOR IN BRICKWORK WITH CONCRETE HEAD - HEAD AND JAMB DETAILS
DOOR IN RENDER WITH CONCRETE SURROUNDS - HEAD AND JAMB DETAILS
DOOR IN BRICKWORK WITH FEATURE BAND HEAD - HEAD AND JAMB DETAILS
DOOR IN 1/2 BRICK 1/2 RENDER WITH FEATURE BAND HEAD - HEAD AND JAMB DETAILS
DOOR IN 1/2 BRICK 1/2 RENDER WITH ARCHED HEAD - HEAD AND JAMB DETAILS
DOOR IN BRICKWORK WITH ARCHED HEAD - HEAD AND JAMB DETAILS
DOOR IN RENDER WITH ARCHED HEAD - HEAD AND JAMB DETAILS
DOOR IN RENDER WITH FEATURE BAND HEAD - HEAD AND JAMB DETAILS
DOOR IN BRICKWORK WITH CONCRETE SURROUNDS - HEAD AND JAMB DETAILS
FRENCH WINDOW IN BRICKWORK WITH CONCRETE HEAD - HEAD AND JAMB DETAILS
FRENCH WINDOW IN RENDER WITH CONCRETE SURROUNDS - HEAD AND JAMB DETAILS
FRENCH WINDOW IN BRICKWORK WITH FEATURE BAND HEAD - HEAD AND JAMB DETAILS
FRENCH WINDOW IN 1/2 BRICK 1/2 RENDER WITH FEATURE BAND HEAD - HEAD AND JAMB DETAILS
FRENCH WINDOW IN 1/2 BRICK 1/2 RENDER WITH ARCHED HEAD - HEAD AND JAMB DETAILS
FRENCH WINDOW IN BRICKWORK WITH ARCHED HEAD - HEAD AND JAMB DETAILS
FRENCH WINDOW IN RENDER WITH ARCHED HEAD - HEAD AND JAMB DETAILS
FRENCH WINDOW IN RENDER WITH FEATURE BAND HEAD - HEAD AND JAMB DETAILS
FRENCH WINDOW IN BRICKWORK WITH CONCRETE SURROUNDS - HEAD AND JAMB DETAILS
AWDD - FF - 28
WINDOW IN RENDER WITH RENDERED RETURNS - HEAD, CILL AND JAMB DETAILS
AWDD - FF - 29
DOOR IN RENDER WITH RENDERED RETURNS - HEAD AND JAMB DETAILS
AWDD - FF - 30
FRENCH WINDOW IN RENDER WITH RENDERED RETURNS - HEAD AND JAMB DETAILS
AWDD - FF - 11
AWDD - FF - 22
AWDD - FF - 33
WINDOW IN STONEWORK WITH CONCRETE SURROUNDS - HEAD, CILL AND JAMB DETAILS
DOOR IN STONEWORK WITH CONCRETE SURROUNDS - HEAD AND JAMB DETAILS
FRENCH WINDOW IN STONEWORK WITH CONCRETE SURROUNDS - HEAD AND JAMB DETAILS
AWDD - FF - 31
AWDD - FF - 32
AWDD - FF - SD
Schedule of Drawings-
Story Homes.C
Burgh Rd Industrial Estate, Carlisle, Cumbria. CA2 7NA.
Tel 01228 640850 Fax 01228 640851
DRAWN BY
CHECKED BY SCALE
DATE
-
CTM 19/09/2013
1:100
Revisions
A
HOUSE TYPE
DRAWING
REVISION
A Drawings AWDD-F-SD 01 to 11 amended. 30-01-15
Window / Door Details(Aircrete Full Fill)
DRAWING NUMBERISSUE
(1)
A
A
A
A
A
A
A
A
A
A
A
Concrete cill 140 x 150mm with
stepped dpc behind
PVCu window
Cavity closed with proprietary insulated
cavity closer with min. thermal
resistance path through the closer of
not less than 0.45m²K/W
15mm rebate
Glidevale MV650 weepvent or similar
to each end of lintel
Precast concrete lintel to outer leaf
PVCu window
Concrete cill 140 x 150mm
Keystone lintel or similar approved
(see manufacturers schedule) with
stepped dpc over
Mastic sealant around all window
perimeters
Mastic sealant around all
window perimeters
PVCu window
Glidevale MV650 weepvent or similar
to each end of lintel
Precast concrete lintel to outer leaf
PVCu window
Cill Section Plan
Head Section Elevation
15mm insulation with min. R value of
0.60m²K/W
Cavity closed with proprietary insulated
cavity closer with min. thermal
resistance path through the closer of
not less than 0.45m²K/W
BBA Certified blown glass mineral
wool insulation.
BBA Certified blown glass mineral
wool insulation.
AWDD - FF - 01
Window in Brickworkwith Concrete Head
-
Story Homes.C
Burgh Rd Industrial Estate, Carlisle, Cumbria. CA2 7NA.
Tel 01228 640850 Fax 01228 640851
DRAWN BY
CHECKED BY SCALE
DATE
-
CTM 19/09/2013
1:100
Revisions
A
HOUSE TYPE
DRAWING
REVISION
A Below cill DPC omitted. 30-01-15
Window / Door Details(Aircrete Full Fill)
DRAWING NUMBERISSUE
(1)
Concrete cill 140 x 175mm with
stepped dpc behind
Cavity closed with proprietary insulated
cavity closer with min. thermal
resistance path through the closer of
not less than 0.45m²K/W
PVCu window
Cavity closed with proprietary insulated
cavity closer with min. thermal
resistance path through the closer of
not less than 0.45m²K/W
15mm rebate
Glidevale MV650 weepvent or similar
to each end of lintel
Precast concrete lintel to outer leaf
Concrete cill 140 x 175mm
Keystone lintel or similar approved
(see manufacturers schedule) with
stepped dpc over
Mastic sealant around all window
perimeters
Mastic sealant around all
window perimeters
PVCu window
Glidevale MV650 weepvent or similar
to each end of lintel
Precast concrete lintel to outer leaf
PVCu window
Concrete jamb 150 x 125mm
Concrete jamb 150 x 125mm
Bell cast render bead securely fixed to
blockwork, in PVCu or stainless steel
or similar approved material
No. of render coats dependant upon
exposure, refer to NHBC Standards
Ch. 6.1 Clause D15 andcomply with
BS 5262. Proprietary rendering finishes
should be applied in accordance with
manufacturers recommendations.
Mortar joints raked out 15mm to
provide key for undercoat
Cill Section Plan
Head Section Elevation
PVCu window
15mm insulation with min. R value of
0.60m²K/W
BBA Certified blown glass mineral
wool insulation.
BBA Certified blown glass mineral
wool insulation.
AWDD - FF - 02
Window in Renderwith Concrete Surrounds
-
Story Homes.C
Burgh Rd Industrial Estate, Carlisle, Cumbria. CA2 7NA.
Tel 01228 640850 Fax 01228 640851
DRAWN BY
CHECKED BY SCALE
DATE
-
CTM 19/09/2013
1:100
Revisions
HOUSE TYPE
DRAWING
REVISION
Window / Door Details(Aircrete Full Fill)
DRAWING NUMBERISSUE
(1) A
A Below cill DPC omitted. 30-01-15
Concrete cill 140 x 150mm with
stepped dpc behind
Cavity closed with proprietary insulated
cavity closer with min. thermal
resistance path through the closer of
not less than 0.45m²K/W
PVCu window
Glidevale MV650 weepvent or similar
to each end of lintel
3 courses of corbelled feature
brickwork top & bottom courses
projecting 15mm
Keystone lintel or similar approved
(see manufacturers schedule) with
stepped dpc over
Mastic sealant around all window
perimeters
PVCu window
15
3 courses of corbelled feature
brickwork top & bottom courses
projecting 15mm
Cavity closed with proprietary insulated
cavity closer with min. thermal
resistance path through the closer of
not less than 0.45m²K/W
15mm rebate
Concrete cill 140 x 150mm
Mastic sealant around all
window perimeters
PVCu window
Cill Section Plan
Head Section Elevation
Glidevale MV650 weepvents @450mm
centres over opening
PVCu window
15mm insulation with min. R value of
0.60m²K/W
BBA Certified blown glass mineral
wool insulation.
BBA Certified blown glass mineral
wool insulation.
AWDD - FF - 03
Window in Brickworkwith Feature Band
-
Story Homes.C
Burgh Rd Industrial Estate, Carlisle, Cumbria. CA2 7NA.
Tel 01228 640850 Fax 01228 640851
DRAWN BY
CHECKED BY SCALE
DATE
-
CTM 19/09/2013
1:100
Revisions
HOUSE TYPE
DRAWING
REVISION
Window / Door Details(Aircrete Full Fill)
DRAWING NUMBERISSUE
(1) A
A Below cill DPC omitted. 30-01-15
Concrete cill 140 x 150mm with
stepped dpc behind
Cavity closed with proprietary insulated
cavity closer with min. thermal
resistance path through the closer of
not less than 0.45m²K/W
PVCu window
Glidevale MV650 weepvent or similar
to each end of lintel
Keystone lintel or similar approved
(see manufacturers schedule) with
stepped dpc over
Mastic sealant around all window
perimeters
PVCu window
Bell cast render bead securely fixed to
blockwork, in PVCu or stainless steel
or similar approved material
No. of render coats dependant upon
exposure, refer to NHBC Standards
Ch. 6.1 Clause D15 andcomply with
BS 5262. Proprietary rendering finishes
should be applied in accordance with
manufacturers recommendations.
Mortar joints raked out 15mm to
provide key for undercoat
Cavity closed with proprietary insulated
cavity closer with min. thermal
resistance path through the closer of
not less than 0.45m²K/W
15mm rebate
Concrete cill 140 x 150mm
Mastic sealant around all
window perimeters
PVCu window
3 courses of corbelled feature
brickwork top & bottom courses
projecting 15mm 15
3 courses of corbelled feature
brickwork top & bottom courses
projecting 15mm
Cill Section Plan
Head Section Elevation
Glidevale MV650 weepvents @450mm
centres over opening
PVCu window
15mm insulation with min. R value of
0.60m²K/W
BBA Certified blown glass mineral
wool insulation.
BBA Certified blown glass mineral
wool insulation.
AWDD - FF - 04
Window in 12Brick/1
2Renderwith Feature Band Head
Story Homes.C
Burgh Rd Industrial Estate, Carlisle, Cumbria. CA2 7NA.
Tel 01228 640850 Fax 01228 640851
DRAWN BY
CHECKED BY SCALE
DATE
-
CTM 19/09/2013
1:100
Revisions
HOUSE TYPE
DRAWING
REVISION
Window / Door Details(Aircrete Full Fill)
DRAWING NUMBERISSUE
(1) A
A Below cill DPC omitted. 30-01-15
Concrete cill 140 x 150mm with
stepped dpc behind
Cavity closed with proprietary insulated
cavity closer with min. thermal
resistance path through the closer of
not less than 0.45m²K/W
PVCu window
Keystone lintel or similar approved
with arch former (see manufacturers
schedule) with stepped dpc over
Mastic sealant around all window
perimeters
Feature brick arch
PVCu window
Bell cast render bead securely fixed to
blockwork, in PVCu or stainless steel
or similar approved material
No. of render coats dependant upon
exposure, refer to NHBC Standards
Ch. 6.1 Clause D15 andcomply with
BS 5262. Proprietary rendering finishes
should be applied in accordance with
manufacturers recommendations.
Mortar joints raked out 15mm to
provide key for undercoat
Cavity closed with proprietary insulated
cavity closer with min. thermal
resistance path through the closer of
not less than 0.45m²K/W
15mm rebate
Concrete cill 140 x 150mm
Mastic sealant around all
window perimeters
PVCu window
Feature brick arch
Cill Section Plan
Head Section Elevation
Glidevale MV650 weepvent or similar
to each end of opening
PVCu window
15mm insulation with min. R value of
0.60m²K/W
BBA Certified blown glass mineral
wool insulation.
BBA Certified blown glass mineral
wool insulation.
AWDD - FF - 05
Window in 12Brick/1
2Renderwith Arched Head
-
Story Homes.C
Burgh Rd Industrial Estate, Carlisle, Cumbria. CA2 7NA.
Tel 01228 640850 Fax 01228 640851
DRAWN BY
CHECKED BY SCALE
DATE
-
CTM 19/09/2013
1:100
Revisions
HOUSE TYPE
DRAWING
REVISION
Window / Door Details(Aircrete Full Fill)
DRAWING NUMBERISSUE
(1) A
A Below cill DPC omitted. 30-01-15
Concrete cill 140 x 150mm with
stepped dpc behind
Cavity closed with proprietary insulated
cavity closer with min. thermal
resistance path through the closer of
not less than 0.45m²K/W
PVCu window
Keystone lintel or similar approved
with arch former (see manufacturers
schedule) with stepped dpc over
Mastic sealant around all window
perimeters
Feature brick arch
PVCu window
Cavity closed with proprietary insulated
cavity closer with min. thermal
resistance path through the closer of
not less than 0.45m²K/W
15mm rebate
Concrete cill 140 x 150mm
Mastic sealant around all
window perimeters
PVCu window
Feature brick arch
Cill Section Plan
Head Section Elevation
Glidevale MV650 weepvent or similar
to each end of opening
PVCu window
15mm insulation with min. R value of
0.60m²K/W
BBA Certified blown glass mineral
wool insulation.
BBA Certified blown glass mineral
wool insulation.
AWDD - FF - 06
Window in Brickworkwith Arched Head
-
Story Homes.C
Burgh Rd Industrial Estate, Carlisle, Cumbria. CA2 7NA.
Tel 01228 640850 Fax 01228 640851
DRAWN BY
CHECKED BY SCALE
DATE
-
CTM 19/09/2013
1:100
Revisions
HOUSE TYPE
DRAWING
REVISION
Window / Door Details(Aircrete Full Fill)
DRAWING NUMBERISSUE
(1) A
A Below cill DPC omitted. 30-01-15
Keystone lintel or similar approved
with arch former (see manufacturers
schedule) with stepped dpc over
Mastic sealant around all window
perimeters
Feature brick arch
PVCu window
Bell cast render bead securely fixed to
blockwork, in PVCu or stainless steel
or similar approved material
No. of render coats dependant upon
exposure, refer to NHBC Standards
Ch. 6.1 Clause D15 andcomply with
BS 5262. Proprietary rendering finishes
should be applied in accordance with
manufacturers recommendations.
Mortar joints raked out 15mm to
provide key for undercoat
PVCu window
Feature brick arch
Cavity closed with proprietary insulated
cavity closer with min. thermal
resistance path through the closer of
not less than 0.45m²K/W
Concrete cill 140 x 175mm
Mastic sealant around all
window perimeters
Plan
Head Section Elevation
Concrete cill 140 x 175mm with
stepped dpc behind
Cavity closed with proprietary insulated
cavity closer with min. thermal
resistance path through the closer of
not less than 0.45m²K/W
PVCu window
Cill Section
19
Glidevale MV650 weepvent or similar
to each end of opening
PVCu window
15mm insulation with min. R value of
0.60m²K/W
BBA Certified blown glass mineral
wool insulation.
BBA Certified blown glass mineral
wool insulation.
AWDD - FF - 07
Window in Renderwith Arched Head
-
Story Homes.C
Burgh Rd Industrial Estate, Carlisle, Cumbria. CA2 7NA.
Tel 01228 640850 Fax 01228 640851
DRAWN BY
CHECKED BY SCALE
DATE
-
CTM 19/09/2013
1:100
Revisions
HOUSE TYPE
DRAWING
REVISION
Window / Door Details(Aircrete Full Fill)
DRAWING NUMBERISSUE
(1)
Concrete cill 140 x 175mm with
stepped dpc behind
Cavity closed with proprietary insulated
cavity closer with min. thermal
resistance path through the closer of
not less than 0.45m²K/W
PVCu window
Keystone lintel or similar approved
(see manufacturers schedule) with
stepped dpc over
Mastic sealant around all window
perimeters
Bell cast render bead securely fixed to
blockwork, in PVCu or stainless steel
or similar approved material
No. of render coats dependant upon
exposure, refer to NHBC Standards
Ch. 6.1 Clause D15 andcomply with
BS 5262. Proprietary rendering finishes
should be applied in accordance with
manufacturers recommendations.
Mortar joints raked out 15mm to
provide key for undercoat
PVCu window
Cavity closed with proprietary insulated
cavity closer with min. thermal
resistance path through the closer of
not less than 0.45m²K/W
Concrete cill 140 x 175mm
PVCu window
3 courses of corbelled feature
brickwork top & bottom courses
projecting 19mm
Cill Section Plan
Head Section Elevation
Glidevale MV650 weepvent or similar
to each end of lintel
19
3 courses of corbelled feature
brickwork top & bottom courses
projecting 19mm
Mastic sealant around all
window perimeters
Glidevale MV650 weepvents @450mm
centres over opening
PVCu window
15mm insulation with min. R value of
0.60m²K/W
BBA Certified blown glass mineral
wool insulation.
BBA Certified blown glass mineral
wool insulation.
AWDD - FF - 08
Window in Renderwith Feature Band Head
-
Story Homes.C
Burgh Rd Industrial Estate, Carlisle, Cumbria. CA2 7NA.
Tel 01228 640850 Fax 01228 640851
DRAWN BY
CHECKED BY SCALE
DATE
-
CTM 19/09/2013
1:100
Revisions
HOUSE TYPE
DRAWING
REVISION
Window / Door Details(Aircrete Full Fill)
DRAWING NUMBERISSUE
(1) A
A Below cill DPC omitted. 30-01-15
Concrete cill 140 x 150mm with
stepped dpc behind
Cavity closed with proprietary insulated
cavity closer with min. thermal
resistance path through the closer of
not less than 0.45m²K/W
PVCu window
Cavity closed with proprietary insulated
cavity closer with min. thermal
resistance path through the closer of
not less than 0.45m²K/W
15mm rebate
Glidevale MV650 weepvent or similar
to each end of lintel
Precast concrete lintel to outer leaf
Concrete cill 140 x 150mm
Keystone lintel or similar approved
(see manufacturers schedule) with
stepped dpc over
Mastic sealant around all window
perimeters
Mastic sealant around all
window perimeters
PVCu window
Glidevale MV650 weepvent or similar
to each end of lintel
Precast concrete lintel to outer leaf
PVCu window
Cill Section Plan
Head Section Elevation
Concrete jamb 150 x 100mm
PVCu window
15mm insulation with min. R value of
0.60m²K/W
BBA Certified blown glass mineral
wool insulation.
BBA Certified blown glass mineral
wool insulation.
AWDD - FF - 09
Window in Brickworkwith Concrete Surrounds
-
Story Homes.C
Burgh Rd Industrial Estate, Carlisle, Cumbria. CA2 7NA.
Tel 01228 640850 Fax 01228 640851
DRAWN BY
CHECKED BY SCALE
DATE
-
CTM 19/09/2013
1:100
Revisions
HOUSE TYPE
DRAWING
REVISION
Window / Door Details(Aircrete Full Fill)
DRAWING NUMBERISSUE
(1) A
A Below cill DPC omitted. 30-01-15
Concrete cill 140 x 175mm with
stepped dpc behind
Cavity closed with proprietary insulated
cavity closer with min. thermal
resistance path through the closer of
not less than 0.45m²K/W
PVCu window
Glidevale MV650 weepvent or similar
to each end of lintel
Precast concrete lintel to outer leaf
Keystone lintel or similar approved
(see manufacturers schedule) with
stepped dpc over
Mastic sealant around all window
perimeters
Glidevale MV650 weepvent or similar
to each end of lintel
Precast concrete lintel to outer leaf
PVCu window
Bell cast render bead securely fixed to
blockwork, in PVCu or stainless steel
or similar approved material
No. of render coats dependant upon
exposure, refer to NHBC Standards
Ch. 6.1 Clause D15 andcomply with
BS 5262. Proprietary rendering finishes
should be applied in accordance with
manufacturers recommendations.
Mortar joints raked out 15mm to
provide key for undercoat
Cill Section Plan
Head Section Elevation
PVCu window
Cavity closed with proprietary insulated
cavity closer with min. thermal
resistance path through the closer of
not less than 0.45m²K/W
Concrete cill 140 x 175mm
Mastic sealant around all
window perimeters
PVCu window
15mm insulation with min. R value of
0.60m²K/W
BBA Certified blown glass mineral
wool insulation.
BBA Certified blown glass mineral
wool insulation.
AWDD - FF - 10
Window in Renderwith Rendered Returns
-
Story Homes.C
Burgh Rd Industrial Estate, Carlisle, Cumbria. CA2 7NA.
Tel 01228 640850 Fax 01228 640851
DRAWN BY
CHECKED BY SCALE
DATE
-
CTM 19/09/2013
1:100
Revisions
HOUSE TYPE
DRAWING
REVISION
Window / Door Details(Aircrete Full Fill)
DRAWING NUMBERISSUE
(1) A
A Below cill DPC omitted. 30-01-15
Concrete cill 140 x 175mm with
stepped dpc behind
Cavity closed with proprietary insulated
cavity closer with min. thermal
resistance path through the closer of
not less than 0.45m²K/W
PVCu window
Cavity closed with proprietary insulated
cavity closer with min. thermal
resistance path through the closer of
not less than 0.45m²K/W
15mm rebate
Glidevale MV650 weepvent or similar
to each end of lintel
Precast concrete lintel to outer leaf
Concrete cill 140 x 175mm
Keystone lintel or similar approved
(see manufacturers schedule) with
stepped dpc over
Mastic sealant around all window
perimeters
Mastic sealant around all
window perimeters
PVCu window
Glidevale MV650 weepvent or similar
to each end of lintel
PVCu window
Concrete jamb 150 x 125mm
Concrete jamb 150 x 125mm
Bell cast render bead securely fixed to
blockwork, in PVCu or stainless steel
or similar approved material
Cill Section Plan
Head Section Elevation
PVCu window
15mm insulation with min. R value of
0.60m²K/W
Precast concrete or stone lintel to
outer leaf
BBA Certified blown glass mineral
wool insulation.
BBA Certified blown glass mineral
wool insulation.
AWDD - FF - 11
Window in Stoneworkwith Concrete Surrounds
-
Story Homes.C
Burgh Rd Industrial Estate, Carlisle, Cumbria. CA2 7NA.
Tel 01228 640850 Fax 01228 640851
DRAWN BY
CHECKED BY SCALE
DATE
-
CTM 19/09/2013
1:100
Revisions
HOUSE TYPE
DRAWING
REVISION
Window / Door Details(Aircrete Full Fill)
DRAWING NUMBERISSUE
(1) A
A Below cill DPC omitted. 30-01-15
1023
1077
27 27Insulated dpc
Glidevale MV650 weepvent or similar
to each end of lintel
Precast concrete lintel to outer leaf
Keystone lintel or similar approved
(see manufacturers schedule) with
stepped dpc over
Mastic sealant around all window
perimeters
Head Section
Doorset
Doorset
Plan
N.B.
See Foundation/Ground Floor Details Booklet
For Appropriate Threshold Detail
Glidevale MV650 weepvent or similar
to each end of lintel
Precast concrete lintel to outer leaf
Doorset
Elevation
Mastic sealant around all frame
perimeters
15mm insulation with min. R value of
0.60m²K/W
15mm insulation with min. R value of
0.60m²K/W
BBA Certified blown glass mineral
wool insulation.
BBA Certified blown glass mineral
wool insulation.AWDD - FF - 12
Door in Brickworkwith Concrete Head
-
Story Homes.C
Burgh Rd Industrial Estate, Carlisle, Cumbria. CA2 7NA.
Tel 01228 640850 Fax 01228 640851
DRAWN BY
CHECKED BY SCALE
DATE
-
CTM 19/09/2013
1:100
Revisions
-
HOUSE TYPE
DRAWING
REVISION
- - -
Window / Door Details(Aircrete Full Fill)
DRAWING NUMBERISSUE
(1)
1023
Doorset
Plan
N.B.
See Foundation/Ground Floor Details Booklet
For Appropriate Threshold Detail
ElevationHead Section
Mastic sealant around all frame
perimeters
Concrete jamb 150 x 125mm
Glidevale MV650 weepvent or similar
to each end of lintel
Keystone lintel or similar approved
(see manufacturers schedule) with
stepped dpc over
Mastic sealant around all window
perimeters
Glidevale MV650 weepvent or similar
to each end of lintel
Precast concrete lintel to outer leaf
Doorset
Precast concrete lintel to outer leaf
Bell cast render bead securely fixed to
blockwork, in PVCu or stainless steel
or similar approved material
No. of render coats dependant upon
exposure, refer to NHBC Standards
Ch. 6.1 Clause D15 andcomply with
BS 5262. Proprietary rendering finishes
should be applied in accordance with
manufacturers recommendations.
Mortar joints raked out 15mm to
provide key for undercoat
Insulated dpc
Doorset
15mm insulation with min. R value of
0.60m²K/W
1077
15mm insulation with min. R value of
0.60m²K/W
BBA Certified blown glass mineral
wool insulation.
BBA Certified blown glass mineral
wool insulation.AWDD - FF - 13
Door in Renderwith Concrete Surrounds
-
Story Homes.C
Burgh Rd Industrial Estate, Carlisle, Cumbria. CA2 7NA.
Tel 01228 640850 Fax 01228 640851
DRAWN BY
CHECKED BY SCALE
DATE
-
CTM 19/09/2013
1:100
Revisions
-
HOUSE TYPE
DRAWING
REVISION
- - -
Window / Door Details(Aircrete Full Fill)
DRAWING NUMBERISSUE
(1)
102327 27
Doorset
Plan
N.B.
See Foundation/Ground Floor Details Booklet
For Appropriate Threshold Detail
Doorset
Elevation
Glidevale MV650 weepvent or similar
to each end of lintel
3 courses of corbelled feature
brickwork top & bottom courses
projecting 15mm
Keystone lintel or similar approved
(see manufacturers schedule) with
stepped dpc over
15
Head Section
3 courses of corbelled feature
brickwork top & bottom courses
projecting 15mm
Mastic sealant around all window
perimeters
Mastic sealant around all frame
perimeters
Glidevale MV650 weepvents @450mm
centres over opening
Insulated dpc
Doorset
15mm insulation with min. R value of
0.60m²K/W
1077
15mm insulation with min. R value of
0.60m²K/W
BBA Certified blown glass mineral
wool insulation.
BBA Certified blown glass mineral
wool insulation.AWDD - FF - 14
Door in Brickworkwith Feature Band Head
-
Story Homes.C
Burgh Rd Industrial Estate, Carlisle, Cumbria. CA2 7NA.
Tel 01228 640850 Fax 01228 640851
DRAWN BY
CHECKED BY SCALE
DATE
-
CTM 19/09/2013
1:100
Revisions
-
HOUSE TYPE
DRAWING
REVISION
- - -
Window / Door Details(Aircrete Full Fill)
DRAWING NUMBERISSUE
(1)
102327 27
Doorset
Plan
N.B.
See Foundation/Ground Floor Details Booklet
For Appropriate Threshold Detail
Doorset
Elevation
Glidevale MV650 weepvent or similar
to each end of lintel
3 courses of corbelled feature
brickwork top & bottom courses
projecting 15mm
Keystone lintel or similar approved
(see manufacturers schedule) with
stepped dpc over
15
Head Section
3 courses of corbelled feature
brickwork top & bottom courses
projecting 15mm
Mastic sealant around all window
perimeters
Bell cast render bead securely fixed to
blockwork, in PVCu or stainless steel
or similar approved material
No. of render coats dependant upon
exposure, refer to NHBC Standards
Ch. 6.1 Clause D15 andcomply with
BS 5262. Proprietary rendering finishes
should be applied in accordance with
manufacturers recommendations.
Mortar joints raked out 15mm to
provide key for undercoat
Mastic sealant around all frame
perimeters
Glidevale MV650 weepvents @450mm
centres over opening
Insulated dpc
Doorset
15mm insulation with min. R value of
0.60m²K/W
1077
15mm insulation with min. R value of
0.60m²K/W
BBA Certified blown glass mineral
wool insulation.
BBA Certified blown glass mineral
wool insulation.AWDD - FF - 15
Door in 12Brick/1
2Renderwith Feature Band Head
-
Story Homes.C
Burgh Rd Industrial Estate, Carlisle, Cumbria. CA2 7NA.
Tel 01228 640850 Fax 01228 640851
DRAWN BY
CHECKED BY SCALE
DATE
-
CTM 19/09/2013
1:100
Revisions
-
HOUSE TYPE
DRAWING
REVISION
- - -
Window / Door Details(Aircrete Full Fill)
DRAWING NUMBERISSUE
(1)
102327 27
Doorset
Plan
N.B.
See Foundation/Ground Floor Details Booklet
For Appropriate Threshold Detail
Doorset
ElevationHead Section
Mastic sealant around all window
perimeters
Keystone lintel or similar approved
with arch former (see manufacturers
schedule) with stepped dpc over
Bell cast render bead securely fixed to
blockwork, in PVCu or stainless steel
or similar approved material
No. of render coats dependant upon
exposure, refer to NHBC Standards
Ch. 6.1 Clause D15 andcomply with
BS 5262. Proprietary rendering finishes
should be applied in accordance with
manufacturers recommendations.
Mortar joints raked out 15mm to
provide key for undercoat
Feature brick arch Feature brick arch
Mastic sealant around all frame
perimeters
Glidevale MV650 weepvent or similar
to each end of opening
Insulated dpc
Doorset
15mm insulation with min. R value of
0.60m²K/W
1077
15mm insulation with min. R value of
0.60m²K/W
BBA Certified blown glass mineral
wool insulation.
BBA Certified blown glass mineral
wool insulation.AWDD - FF - 16
Door in 12Brick/1
2Renderwith Arched Head
-
Story Homes.C
Burgh Rd Industrial Estate, Carlisle, Cumbria. CA2 7NA.
Tel 01228 640850 Fax 01228 640851
DRAWN BY
CHECKED BY SCALE
DATE
-
CTM 19/09/2013
1:100
Revisions
-
HOUSE TYPE
DRAWING
REVISION
- - -
Window / Door Details(Aircrete Full Fill)
DRAWING NUMBERISSUE
(1)
102327 27
Doorset
Plan
N.B.
See Foundation/Ground Floor Details Booklet
For Appropriate Threshold Detail
Doorset
ElevationHead Section
Mastic sealant around all window
perimeters
Keystone lintel or similar approved
with arch former (see manufacturers
schedule) with stepped dpc over
Feature brick arch Feature brick arch
Mastic sealant around all frame
perimeters
Glidevale MV650 weepvent or similar
to each end of opening
Insulated dpc
Doorset
15mm insulation with min. R value of
0.60m²K/W
1077
15mm insulation with min. R value of
0.60m²K/W
BBA Certified blown glass mineral
wool insulation.
BBA Certified blown glass mineral
wool insulation.AWDD - FF - 17
Door in Brickworkwith Arched Head
-
Story Homes.C
Burgh Rd Industrial Estate, Carlisle, Cumbria. CA2 7NA.
Tel 01228 640850 Fax 01228 640851
DRAWN BY
CHECKED BY SCALE
DATE
-
CTM 19/09/2013
1:100
Revisions
-
HOUSE TYPE
DRAWING
REVISION
- - -
Window / Door Details(Aircrete Full Fill)
DRAWING NUMBERISSUE
(1)
1077
Doorset
Plan
N.B.
See Foundation/Ground Floor Details Booklet
For Appropriate Threshold Detail
Doorset
ElevationHead Section
Bell cast render bead securely fixed to
blockwork, in PVCu or stainless steel
or similar approved material
No. of render coats dependant upon
exposure, refer to NHBC Standards
Ch. 6.1 Clause D15 andcomply with
BS 5262. Proprietary rendering finishes
should be applied in accordance with
manufacturers recommendations.
Mortar joints raked out 15mm to
provide key for undercoat
Feature brick arch Feature brick arch
Mastic sealant around all window
perimeters
Keystone lintel or similar approved
with arch former (see manufacturers
schedule) with stepped dpc over
Mastic sealant around all frame
perimeters
19
Glidevale MV650 weepvent or similar
to each end of opening
Insulated dpc
Doorset
15mm insulation with min. R value of
0.60m²K/W
1077
15mm insulation with min. R value of
0.60m²K/W
BBA Certified blown glass mineral
wool insulation.
BBA Certified blown glass mineral
wool insulation.AWDD - FF - 18
Door in Renderwith Arched Head
-
Story Homes.C
Burgh Rd Industrial Estate, Carlisle, Cumbria. CA2 7NA.
Tel 01228 640850 Fax 01228 640851
DRAWN BY
CHECKED BY SCALE
DATE
-
CTM 19/09/2013
1:100
Revisions
-
HOUSE TYPE
DRAWING
REVISION
- - -
Window / Door Details(Aircrete Full Fill)
DRAWING NUMBERISSUE
(1)
1077
Doorset
Plan
N.B.
See Foundation/Ground Floor Details Booklet
For Appropriate Threshold Detail
ElevationHead Section
Bell cast render bead securely fixed to
blockwork, in PVCu or stainless steel
or similar approved material
No. of render coats dependant upon
exposure, refer to NHBC Standards
Ch. 6.1 Clause D15 andcomply with
BS 5262. Proprietary rendering finishes
should be applied in accordance with
manufacturers recommendations.
Mortar joints raked out 15mm to
provide key for undercoat
Feature brick arch
Mastic sealant around all window
perimeters
Keystone lintel or similar approved
with arch former (see manufacturers
schedule) with stepped dpc over
Mastic sealant around all frame
perimeters
3 courses of corbelled feature
brickwork top & bottom courses
projecting 19mm
Doorset
Glidevale MV650 weepvents @450mm
centres over opening
Insulated dpc
Doorset
15mm insulation with min. R value of
0.60m²K/W
1077
15mm insulation with min. R value of
0.60m²K/W
BBA Certified blown glass mineral
wool insulation.
BBA Certified blown glass mineral
wool insulation.AWDD - FF - 19
Door in Renderwith Feature Band Head
-
Story Homes.C
Burgh Rd Industrial Estate, Carlisle, Cumbria. CA2 7NA.
Tel 01228 640850 Fax 01228 640851
DRAWN BY
CHECKED BY SCALE
DATE
-
CTM 19/09/2013
1:100
Revisions
-
HOUSE TYPE
DRAWING
REVISION
- - -
Window / Door Details(Aircrete Full Fill)
DRAWING NUMBERISSUE
(1)
102327
Glidevale MV650 weepvent or similar
to each end of lintel
Precast concrete lintel to outer leaf
Keystone lintel or similar approved
(see manufacturers schedule) with
stepped dpc over
Mastic sealant around all window
perimeters
Head Section
Doorset
Plan
Concrete jamb 150 x 100mm
N.B.
See Foundation/Ground Floor Details Booklet
For Appropriate Threshold Detail
Elevation
Glidevale MV650 weepvent or similar
to each end of lintel
Precast concrete lintel to outer leaf
Doorset
27
Mastic sealant around all frame
perimeters
Insulated dpc
Doorset
15mm insulation with min. R value of
0.60m²K/W
1077
15mm insulation with min. R value of
0.60m²K/W
BBA Certified blown glass mineral
wool insulation.
BBA Certified blown glass mineral
wool insulation.AWDD - FF - 20
Door in Brickworkwith Concrete Surrounds
-
Story Homes.C
Burgh Rd Industrial Estate, Carlisle, Cumbria. CA2 7NA.
Tel 01228 640850 Fax 01228 640851
DRAWN BY
CHECKED BY SCALE
DATE
-
CTM 19/09/2013
1:100
Revisions
-
HOUSE TYPE
DRAWING
REVISION
- - -
Window / Door Details(Aircrete Full Fill)
DRAWING NUMBERISSUE
(1)
Plan
N.B.
See Foundation/Ground Floor Details Booklet
For Appropriate Threshold Detail
ElevationHead Section
Glidevale MV650 weepvent or similar
to each end of lintel
Keystone lintel or similar approved
(see manufacturers schedule) with
stepped dpc over
Mastic sealant around all window
perimeters
Glidevale MV650 weepvent or similar
to each end of lintel
Precast concrete lintel to outer leaf
Doorset
Precast concrete lintel to outer leaf
Bell cast render bead securely fixed to
blockwork, in PVCu or stainless steel
or similar approved material
No. of render coats dependant upon
exposure, refer to NHBC Standards
Ch. 6.1 Clause D15 andcomply with
BS 5262. Proprietary rendering finishes
should be applied in accordance with
manufacturers recommendations.
Mortar joints raked out 15mm to
provide key for undercoat
1077
Doorset
Mastic sealant around all frame
perimeters
Insulated dpc
Doorset
15mm insulation with min. R value of
0.60m²K/W
1077
15mm insulation with min. R value of
0.60m²K/W
BBA Certified blown glass mineral
wool insulation.
BBA Certified blown glass mineral
wool insulation. AWDD - FF - 21
Door in Renderwith Rendered Returns
-
Story Homes.C
Burgh Rd Industrial Estate, Carlisle, Cumbria. CA2 7NA.
Tel 01228 640850 Fax 01228 640851
DRAWN BY
CHECKED BY SCALE
DATE
-
CTM 19/09/2013
1:100
Revisions
-
HOUSE TYPE
DRAWING
REVISION
- - -
Window / Door Details(Aircrete Full Fill)
DRAWING NUMBERISSUE
(1)
1023
Doorset
Plan
N.B.
See Foundation/Ground Floor Details Booklet
For Appropriate Threshold Detail
ElevationHead Section
Mastic sealant around all frame
perimeters
Concrete jamb 150 x 125mm
Glidevale MV650 weepvent or similar
to each end of lintel
Keystone lintel or similar approved
(see manufacturers schedule) with
stepped dpc over
Mastic sealant around all window
perimeters
Glidevale MV650 weepvent or similar
to each end of lintel
Precast concrete or stone lintel to
outer leaf
Doorset
Precast concrete lintel to outer leaf
Bell cast render bead securely fixed to
blockwork, in PVCu or stainless steel
or similar approved material
Insulated dpc
Doorset
15mm insulation with min. R value of
0.60m²K/W
1077
15mm insulation with min. R value of
0.60m²K/W
BBA Certified blown glass mineral
wool insulation.
BBA Certified blown glass mineral
wool insulation. AWDD - FF - 22
Door in Stonework
with Concrete Surrounds-
Story Homes.C
Burgh Rd Industrial Estate, Carlisle, Cumbria. CA2 7NA.
Tel 01228 640850 Fax 01228 640851
DRAWN BY
CHECKED BY SCALE
DATE
-
CTM 19/09/2013
1:100
Revisions
-
HOUSE TYPE
DRAWING
REVISION
- - -
Window / Door Details(Aircrete Full Fill)
DRAWING NUMBERISSUE
(1)
Plan
N.B.
See Foundation/Ground Floor Details Booklet
For Appropriate Threshold Detail
Glidevale MV650 weepvent or similar
to each end of lintel
Precast concrete lintel to outer leaf
Elevation
Cavity closed with proprietary insulated
cavity closer with min. thermal
resistance path through the closer of
not less than 0.45m²K/W
15mm rebate
Mastic sealant around all
frame perimeters
Glidevale MV650 weepvent or similar
to each end of lintel
Precast concrete lintel to outer leaf
PVCu french window
Keystone lintel or similar approved
(see manufacturers schedule) with
stepped dpc over
Mastic sealant around all window
perimeters
Head Section
PVCu french window
15mm insulation with min. R value of
0.60m²K/W
BBA Certified blown glass mineral
wool insulation.
BBA Certified blown glass mineral
wool insulation.
AWDD - FF - 23
French Window in Brickwork
with Concrete Head-
Story Homes.C
Burgh Rd Industrial Estate, Carlisle, Cumbria. CA2 7NA.
Tel 01228 640850 Fax 01228 640851
DRAWN BY
CHECKED BY SCALE
DATE
-
CTM 19/09/2013
1:100
Revisions
-
HOUSE TYPE
DRAWING
REVISION
- - -
Window / Door Details(Aircrete Full Fill)
DRAWING NUMBERISSUE
(1)
Plan
N.B.
See Foundation/Ground Floor Details Booklet
For Appropriate Threshold Detail
Elevation
Glidevale MV650 weepvent or similar
to each end of lintel
Precast concrete lintel to outer leaf
Cavity closed with proprietary insulated
cavity closer with min. thermal
resistance path through the closer of
not less than 0.45m²K/W
15mm rebate
Concrete jamb 150 x 125mm
Mastic sealant around all
frame perimeters
Glidevale MV650 weepvent or similar
to each end of lintel
Precast concrete lintel to outer leaf
Keystone lintel or similar approved
(see manufacturers schedule) with
stepped dpc over
Mastic sealant around all window
perimeters
Bell cast render bead securely fixed to
blockwork, in PVCu or stainless steel
or similar approved material
No. of render coats dependant upon
exposure, refer to NHBC Standards
Ch. 6.1 Clause D15 andcomply with
BS 5262. Proprietary rendering finishes
should be applied in accordance with
manufacturers recommendations.
Mortar joints raked out 15mm to
provide key for undercoat
Head Section
PVCu french window
PVCu french window
15mm insulation with min. R value of
0.60m²K/W
BBA Certified blown glass mineral
wool insulation.
BBA Certified blown glass mineral
wool insulation. AWDD - FF - 24
French Window in Render
with Concrete Surrounds-
Story Homes.C
Burgh Rd Industrial Estate, Carlisle, Cumbria. CA2 7NA.
Tel 01228 640850 Fax 01228 640851
DRAWN BY
CHECKED BY SCALE
DATE
-
CTM 19/09/2013
1:100
Revisions
-
HOUSE TYPE
DRAWING
REVISION
- - -
Window / Door Details(Aircrete Full Fill)
DRAWING NUMBERISSUE
(1)
Plan
N.B.
See Foundation/Ground Floor Details Booklet
For Appropriate Threshold Detail
Elevation
Glidevale MV650 weepvents @450mm
centres over opening
3 courses of corbelled feature
brickwork top & bottom courses
projecting 15mm
Cavity closed with proprietary insulated
cavity closer with min. thermal
resistance path through the closer of
not less than 0.45m²K/W
15mm rebate
Mastic sealant around all
frame perimeters
Glidevale MV650 weepvent or similar
to each end of lintel
3 courses of corbelled feature
brickwork top & bottom courses
projecting 15mm
Keystone lintel or similar approved
(see manufacturers schedule) with
stepped dpc over
Mastic sealant around all window
perimeters
15
Head Section
PVCu french window
PVCu french window
15mm insulation with min. R value of
0.60m²K/W
BBA Certified blown glass mineral
wool insulation.
BBA Certified blown glass mineral
wool insulation.
AWDD - FF - 25
French Window in Brickwork
with Feature Band Head-
Story Homes.C
Burgh Rd Industrial Estate, Carlisle, Cumbria. CA2 7NA.
Tel 01228 640850 Fax 01228 640851
DRAWN BY
CHECKED BY SCALE
DATE
-
CTM 19/09/2013
1:100
Revisions
-
HOUSE TYPE
DRAWING
REVISION
- - -
Window / Door Details(Aircrete Full Fill)
DRAWING NUMBERISSUE
(1)
Plan
N.B.
See Foundation/Ground Floor Details Booklet
For Appropriate Threshold Detail
Elevation
3 courses of corbelled feature
brickwork top & bottom courses
projecting 15mm
Cavity closed with proprietary insulated
cavity closer with min. thermal
resistance path through the closer of
not less than 0.45m²K/W
15mm rebate
Mastic sealant around all
frame perimeters
Glidevale MV650 weepvent or similar
to each end of lintel
Keystone lintel or similar approved
(see manufacturers schedule) with
stepped dpc over
Mastic sealant around all window
perimeters
Bell cast render bead securely fixed to
blockwork, in PVCu or stainless steel
or similar approved material
No. of render coats dependant upon
exposure, refer to NHBC Standards
Ch. 6.1 Clause D15 andcomply with
BS 5262. Proprietary rendering finishes
should be applied in accordance with
manufacturers recommendations.
Mortar joints raked out 15mm to
provide key for undercoat
3 courses of corbelled feature
brickwork top & bottom courses
projecting 15mm 15
Head Section
PVCu french window
Glidevale MV650 weepvents @450mm
centres over opening
PVCu french window
15mm insulation with min. R value of
0.60m²K/W
BBA Certified blown glass mineral
wool insulation.
BBA Certified blown glass mineral
wool insulation.
AWDD - FF - 26
French Window in 12Brick/1
2Render
with Feature Band Head-
Story Homes.C
Burgh Rd Industrial Estate, Carlisle, Cumbria. CA2 7NA.
Tel 01228 640850 Fax 01228 640851
DRAWN BY
CHECKED BY SCALE
DATE
-
CTM 19/09/2013
1:100
Revisions
-
HOUSE TYPE
DRAWING
REVISION
- - -
Window / Door Details(Aircrete Full Fill)
DRAWING NUMBERISSUE
(1)
Plan
N.B.
See Foundation/Ground Floor Details Booklet
For Appropriate Threshold Detail
Elevation
Glidevale MV650 weepvent or similar
to each end of opening
Feature brick arch
Cavity closed with proprietary insulated
cavity closer with min. thermal
resistance path through the closer of
not less than 0.45m²K/W
15mm rebate
Mastic sealant around all
frame perimeters
Keystone lintel or similar approved
with arch former (see manufacturers
schedule) with stepped dpc over
Mastic sealant around all window
perimeters
Bell cast render bead securely fixed to
blockwork, in PVCu or stainless steel
or similar approved material
No. of render coats dependant upon
exposure, refer to NHBC Standards
Ch. 6.1 Clause D15 andcomply with
BS 5262. Proprietary rendering finishes
should be applied in accordance with
manufacturers recommendations.
Mortar joints raked out 15mm to
provide key for undercoat
Feature brick arch
Head Section
PVCu french window
PVCu french window
15mm insulation with min. R value of
0.60m²K/W
BBA Certified blown glass mineral
wool insulation.
BBA Certified blown glass mineral
wool insulation.
AWDD - FF - 27
French Window in 12Brick/1
2Render
with Arched Head-
Story Homes.C
Burgh Rd Industrial Estate, Carlisle, Cumbria. CA2 7NA.
Tel 01228 640850 Fax 01228 640851
DRAWN BY
CHECKED BY SCALE
DATE
-
CTM 19/09/2013
1:100
Revisions
-
HOUSE TYPE
DRAWING
REVISION
- - -
Window / Door Details(Aircrete Full Fill)
DRAWING NUMBERISSUE
(1)
Plan
N.B.
See Foundation/Ground Floor Details Booklet
For Appropriate Threshold Detail
Elevation
Feature brick arch
Cavity closed with proprietary insulated
cavity closer with min. thermal
resistance path through the closer of
not less than 0.45m²K/W
15mm rebate
Mastic sealant around all
frame perimeters
Keystone lintel or similar approved
with arch former (see manufacturers
schedule) with stepped dpc over
Mastic sealant around all window
perimeters
Feature brick arch
Head Section
PVCu french window
Glidevale MV650 weepvent or similar
to each end of opening
PVCu french window
15mm insulation with min. R value of
0.60m²K/W
BBA Certified blown glass mineral
wool insulation.
BBA Certified blown glass mineral
wool insulation.AWDD - FF - 28
French Window in Brickwork
with Arched Head-
Story Homes.C
Burgh Rd Industrial Estate, Carlisle, Cumbria. CA2 7NA.
Tel 01228 640850 Fax 01228 640851
DRAWN BY
CHECKED BY SCALE
DATE
-
CTM 19/09/2013
1:100
Revisions
-
HOUSE TYPE
DRAWING
REVISION
- - -
Window / Door Details(Aircrete Full Fill)
DRAWING NUMBERISSUE
(1)
Plan
N.B.
See Foundation/Ground Floor Details Booklet
For Appropriate Threshold Detail
Elevation
Feature brick arch
Cavity closed with proprietary insulated
cavity closer with min. thermal
resistance path through the closer of
not less than 0.45m²K/W
Mastic sealant around all
frame perimeters
Keystone lintel or similar approved
with arch former (see manufacturers
schedule) with stepped dpc over
Mastic sealant around all window
perimeters
Bell cast render bead securely fixed to
blockwork, in PVCu or stainless steel
or similar approved material
No. of render coats dependant upon
exposure, refer to NHBC Standards
Ch. 6.1 Clause D15 andcomply with
BS 5262. Proprietary rendering finishes
should be applied in accordance with
manufacturers recommendations.
Mortar joints raked out 15mm to
provide key for undercoat
Feature brick arch
Head Section
19
PVCu french window
Glidevale MV650 weepvent or similar
to each end of opening
PVCu french window
15mm insulation with min. R value of
0.60m²K/W
BBA Certified blown glass mineral
wool insulation.
BBA Certified blown glass mineral
wool insulation.
AWDD - FF - 29
French Window in Render
with Arched Head-
Story Homes.C
Burgh Rd Industrial Estate, Carlisle, Cumbria. CA2 7NA.
Tel 01228 640850 Fax 01228 640851
DRAWN BY
CHECKED BY SCALE
DATE
-
CTM 19/09/2013
1:100
Revisions
-
HOUSE TYPE
DRAWING
REVISION
- - -
Window / Door Details(Aircrete Full Fill)
DRAWING NUMBERISSUE
(1)
Plan
N.B.
See Foundation/Ground Floor Details Booklet
For Appropriate Threshold Detail
Elevation
3 courses of corbelled feature
brickwork top & bottom courses
projecting 19mm
Cavity closed with proprietary insulated
cavity closer with min. thermal
resistance path through the closer of
not less than 0.45m²K/W
Mastic sealant around all
frame perimeters
Keystone lintel or similar approved
(see manufacturers schedule) with
stepped dpc over
Mastic sealant around all window
perimeters
Bell cast render bead securely fixed to
blockwork, in PVCu or stainless steel
or similar approved material
No. of render coats dependant upon
exposure, refer to NHBC Standards
Ch. 6.1 Clause D15 andcomply with
BS 5262. Proprietary rendering finishes
should be applied in accordance with
manufacturers recommendations.
Mortar joints raked out 15mm to
provide key for undercoat
Head Section
Glidevale MV650 weepvent or similar
to each end of lintel
19
3 courses of corbelled feature
brickwork top & bottom courses
projecting 19mm
PVCu french window
Glidevale MV650 weepvents @450mm
centres over opening
PVCu french window
15mm insulation with min. R value of
0.60m²K/W
BBA Certified blown glass mineral
wool insulation.
BBA Certified blown glass mineral
wool insulation.
AWDD - FF - 30
French Window in Render
with Feature Band Head -
Story Homes.C
Burgh Rd Industrial Estate, Carlisle, Cumbria. CA2 7NA.
Tel 01228 640850 Fax 01228 640851
DRAWN BY
CHECKED BY SCALE
DATE
-
CTM 19/09/2013
1:100
Revisions
-
HOUSE TYPE
DRAWING
REVISION
- - -
Window / Door Details(Aircrete Full Fill)
DRAWING NUMBERISSUE
(1)
Plan
Elevation
Glidevale MV650 weepvent or similar
to each end of lintel
Precast concrete lintel to outer leaf
Cavity closed with proprietary insulated
cavity closer with min. thermal
resistance path through the closer of
not less than 0.45m²K/W
15mm rebate
Concrete jamb 150 x 125mm
Mastic sealant around all
frame perimeters
Glidevale MV650 weepvent or similar
to each end of lintel
Precast concrete lintel to outer leaf
Keystone lintel or similar approved
(see manufacturers schedule) with
stepped dpc over
Mastic sealant around all window
perimeters
Head Section
PVCu french window
PVCu french window
15mm insulation with min. R value of
0.60m²K/W
BBA Certified blown glass mineral
wool insulation.
BBA Certified blown glass mineral
wool insulation. AWDD - FF - 31
French Window in Render
with Rendered Returns-
Story Homes.C
Burgh Rd Industrial Estate, Carlisle, Cumbria. CA2 7NA.
Tel 01228 640850 Fax 01228 640851
DRAWN BY
CHECKED BY SCALE
DATE
-
CTM 19/09/2013
1:100
Revisions
-
HOUSE TYPE
DRAWING
REVISION
- - -
Window / Door Details(Aircrete Full Fill)
DRAWING NUMBERISSUE
(1)
Plan
N.B.
See Foundation/Ground Floor Details Booklet
For Appropriate Threshold Detail
Elevation
Glidevale MV650 weepvent or similar
to each end of lintel
Precast concrete lintel to outer leaf
Glidevale MV650 weepvent or similar
to each end of lintel
Precast concrete lintel to outer leaf
Keystone lintel or similar approved
(see manufacturers schedule) with
stepped dpc over
Mastic sealant around all window
perimeters
Bell cast render bead securely fixed to
blockwork, in PVCu or stainless steel
or similar approved material
No. of render coats dependant upon
exposure, refer to NHBC Standards
Ch. 6.1 Clause D15 andcomply with
BS 5262. Proprietary rendering finishes
should be applied in accordance with
manufacturers recommendations.
Mortar joints raked out 15mm to
provide key for undercoat
Head Section
PVCu french window
Cavity closed with proprietary insulated
cavity closer with min. thermal
resistance path through the closer of
not less than 0.45m²K/W
Mastic sealant around all
frame perimeters
PVCu french window
15mm insulation with min. R value of
0.60m²K/W
BBA Certified blown glass mineral
wool insulation.
BBA Certified blown glass mineral
wool insulation.
AWDD - FF - 32
French Window in Brickwork
with Concrete Surrounds-
Story Homes.C
Burgh Rd Industrial Estate, Carlisle, Cumbria. CA2 7NA.
Tel 01228 640850 Fax 01228 640851
DRAWN BY
CHECKED BY SCALE
DATE
-
CTM 19/09/2013
1:100
Revisions
-
HOUSE TYPE
DRAWING
REVISION
- - -
Window / Door Details(Aircrete Full Fill)
DRAWING NUMBERISSUE
(1)
Plan
N.B.
See Foundation/Ground Floor Details Booklet
For Appropriate Threshold Detail
Elevation
Glidevale MV650 weepvent or similar
to each end of lintel
Precast concrete lintel to outer leaf
Glidevale MV650 weepvent or similar
to each end of lintel
Precast concrete lintel to outer leaf
Keystone lintel or similar approved
(see manufacturers schedule) with
stepped dpc over
Mastic sealant around all window
perimeters
Bell cast render bead securely fixed to
blockwork, in PVCu or stainless steel
or similar approved material
No. of render coats dependant upon
exposure, refer to NHBC Standards
Ch. 6.1 Clause D15 andcomply with
BS 5262. Proprietary rendering finishes
should be applied in accordance with
manufacturers recommendations.
Mortar joints raked out 15mm to
provide key for undercoat
Head Section
PVCu french window
Cavity closed with proprietary insulated
cavity closer with min. thermal
resistance path through the closer of
not less than 0.45m²K/W
Mastic sealant around all
frame perimeters
PVCu french window
15mm insulation with min. R value of
0.60m²K/W
BBA Certified blown glass mineral
wool insulation.
BBA Certified blown glass mineral
wool insulation.
AWDD - FF - 33
French Window in Stonework
with Concrete Surrounds-
Story Homes.C
Burgh Rd Industrial Estate, Carlisle, Cumbria. CA2 7NA.
Tel 01228 640850 Fax 01228 640851
DRAWN BY
CHECKED BY SCALE
DATE
-
CTM 19/09//2013
1:100
Revisions
-
HOUSE TYPE
DRAWING
REVISION
- - -
Window / Door Details(Aircrete Full Fill)
DRAWING NUMBERISSUE
(1)
Recommended