SYSTEM-1S.NO NODE NO. PROPOSED SUPPORT
1 6000 Spring(TRUNION)2 290 ₊y & guide (5mm gap)3 390 ₊y & guide (5mm gap)4 395 ₊y & guide (5mm gap)5 6200 ₊Y & Z(TRUNION)6 6400 ₊Y & Z(TRUNION)7 1550 ₊Y & Guide8 1930 ₊Y & X(5mm gap)9 2070 ₊Y & Guide
10 2310 ₊Y & Guide11 6450 ₊Y & Guide12 3330 ₊Y & Guide (5mm gap)13 680 GUIDE(15mm)14 2690 ₊Y & Guide (5mm gap)
NOTE:1. FOR GUIDE DEATIL REFER AKER SUPPORT STANDARD DOCUMENT REF. NUMBER G-11-7-5 AND G-11-7-2.
support restraint proposed at 290 and 395 is not feasible.
AT NODE 680 GUIDE IS PROPOSED BUT NOT TAKING ANY LOAD WHICH IS FEASIBLE BUT IT TAKES GREAT EFFORT TO DO THAT.(IN STATIC ANALYSIS)
NODE NUMBER 1930,3330 NOT TAKING ANY LOAD AND MOST OF THE OTHER GUIDE THAT WE PROPOSED NOT TAKING MUCH LOAD.
SYSTEM-1AS-BUILT SUPPORT ADDITION DELETION
₊Y (TRUNION) SPRING RESTING NA NA GUIDE G-11-7-5₊Y GUIDE G-11-7-2₊Y GUIDE G-11-7-5
₊Y (TRUNION) GUIDE G-11-7-5₊Y (TRUNION) GUIDE G-11-7-2
₊Y GUIDE G-11-7-2₊Y GUIDE G-11-7-2₊Y GUIDE G-11-7-2₊Y GUIDE G-11-7-2₊Y GUIDE G-11-7-2₊Y GUIDE G-11-7-2₊Y GUIDE G-11-7-2₊Y GUIDE G-11-7-2
AKER SUPPORT REF.
1. FOR GUIDE DEATIL REFER AKER SUPPORT STANDARD DOCUMENT REF. NUMBER G-11-7-5 AND G-11-7-2.
AT NODE 680 GUIDE IS PROPOSED BUT NOT TAKING ANY LOAD WHICH IS FEASIBLE BUT IT TAKES GREAT EFFORT TO DO
NODE NUMBER 1930,3330 NOT TAKING ANY LOAD AND MOST OF THE OTHER GUIDE THAT WE PROPOSED NOT TAKING
SYSTEM-1GLE SUPPORT REF. DOC. NO.
24358607-GLIN05-29-P-SDRG-SYS1-001
SYSTEM 4NODE NUMBER ISMB SECTION LENGTH
1700 200 4002220 200 500660 250 550
3720 300 3503740 300 4002040 200 5602110 250 3501620 300 650
1680 200 500
4730 250 5203300 300 5003280 300 5003230 300 5003150 300 5003090 300 5003560 300 5003640 300 500
SYSTEM 4RESTRAINT AKER SUPPORT REF.
NA NAGUIDE G-11-7-5GUIDE G-11-7-5GUIDE G-11-7-5GUIDE G-11-7-5GUIDE G-11-7-5
NA G-11-7-5NA G-11-7-5
LIMIT STOP G-11-7-5
NA G-11-7-5GUIDE G-11-7-5GUIDE G-11-7-5
NA G-11-7-5NA G-11-7-5
GUIDE,LIMIT STOP G-11-7-5GUIDE G-11-7-5
NA G-11-7-5
SYSTEM 4GLE SUPPORT REF. DOC. NO.
24358607-GLIN05-29-P-SDRG-SYS4-001
NOTE:1. DURING INSPECTION AT SITE ISMB SECTION FOUND DISTORTED .2. THESE DISTORTED ISMB SECTION HAS TO BE REPLACED WITH REF. DOCUMENT NUMBER 24358607-GLIN05-29-P-SDRG-SYS4-001.3. FOR GUIDE DEATIL REFER AKER SUPPORT STANDARD DOCUMENT REF. NUMBER G-11-7 AND G-11-6.
SYSTEM -2S.NO NODE NO. PROPOSED SUPPORT
1 6000 Spring(TRUNION)2 120 X & Z( Both 25mm gap)3 150 Spring4 200 Spring5 500 ₊y & Guide (25mm gap)6 19025 ₊Y7 25000 Bottom Hanger & Z(TRUNION)8 19170 ₊Y & Guide 9 20155 ₊Y
10 26000 Bottom Hanger & Z (TRUNION)11 640 SPRING REMOVED IN CALCULATION12 4990 SPRING REMOVED IN CALCULATION
FX
NODE 500
NODE 120
NOTE:1. FOR GUIDE DEATIL REFER AKER SUPPORT STANDARD DOCUMENT REF. NUMBER G-11-7-2 AND G-11-7-5.
OCC -12864OPE-6320
SYSTEM -2AS-BUILT SUPPORT ADDITION DELETION
₊Y (TRUNION)& Guide SPRING GUIDE ,RESTING Z(GUIDE) GUIDE
₊Y & Guide Spring ₊Y & Guide₊Y & Guide Spring ₊Y & Guide
₊Y & Guide (3mm gap) GUIDE GAP INCREASED BY 22MM NANo Support Here RESTING
Bottom Hanger(TRUNION) GUIDE₊Y GUIDE
No Support Here RESTING Bottom Hanger(TRUNION) GUIDE
SPRING NO NEED TO DELETE SPRING SPRING NO NEED TO DELETE SPRING
UNIT (KG)
FZ
NOTE:1. FOR GUIDE DEATIL REFER AKER SUPPORT STANDARD DOCUMENT REF. NUMBER G-11-7-2 AND G-11-7-5.
IN FINAL SUBMISSION MODEL TWO RESTING ARE PROPOSED AT NODE NUMBER 5045, 695 WHICH REQUIRE HOT WORK, BUT IN INTERNAL DISCUSSION IT IS FINALIZED THAT GLE WILL AVOID ANY KIND OF HOT WORK AT SITE AND LATER ON DISCUSION WITH IOCL FOOTING PROBLEM FOR THESE TWO NEW RESTING COME INTO LIME LIGHT.
GEL ALSO SUGGEST NOT TO REMOVE SPRING SUPPORT AT NODE NUMBER 4990,640 WHICH IS NOT TAKEN IN CALCULATION IN FINAL SUBMITION.
IN FINAL C2 FILE SPRING SUPPRT DIDN,T SHOWN.
AT NODE NUMBER 120 CROSS GUIDE IS PROPOSED BUT ARRANGEMENT FOR THAT IS NOT SUBMITTED.
OCC -9210OPE--5580
OCC-9210OPE-5580
SYSTEM -2GLE SUPPORT REF. DOC. NO.
24358607-GLIN05-29-P-SDRG-SYS2-003G-11-7-5
24358607-GLIN05-29-P-SDRG-SYS2-00224358607-GLIN05-29-P-SDRG-SYS2-001
PS11-24 24358607-GLIN05-29-P-SDRG-SYS2-004G-11-7-2G-11-7-2PS11-24 24358607-GLIN05-29-P-SDRG-SYS2-004G-11-7-2
AKER SUPPORT REF.
1. FOR GUIDE DEATIL REFER AKER SUPPORT STANDARD DOCUMENT REF. NUMBER G-11-7-2 AND G-11-7-5.
IN FINAL SUBMISSION MODEL TWO RESTING ARE PROPOSED AT NODE NUMBER 5045, 695 WHICH REQUIRE HOT WORK, BUT IN INTERNAL DISCUSSION IT IS FINALIZED THAT GLE WILL AVOID ANY KIND OF HOT WORK AT SITE AND LATER ON DISCUSION WITH IOCL FOOTING PROBLEM FOR THESE TWO NEW RESTING COME INTO LIME LIGHT.
GEL ALSO SUGGEST NOT TO REMOVE SPRING SUPPORT AT NODE NUMBER 4990,640 WHICH IS NOT TAKEN IN CALCULATION IN FINAL
AT NODE NUMBER 120 CROSS GUIDE IS PROPOSED BUT ARRANGEMENT FOR THAT IS NOT SUBMITTED.
SYSTEM-3S.NO NODE NO. PROPOSED SUPPORT
1 1380 ₊Y2 1410 ₊Y3 350 NA4 8055 Y,LIM5 7090 Y,LIM6 375 SPRING REMOVED IN CALCULATION7 345 SPRING REMOVED IN CALCULATION
FY1380 -51961410 -1400
NOTE:1. FOR GUIDE DEATIL REFER AKER SUPPORT STANDARD DOCUMENT REF. NUMBER G-11-7 AND G-11-6.2. FOR LIMIT STOP DEATIL REFER AKER SUPPORT STANDARD DOCUMENT REF. NUMBER LS-11-12.
In final model/report submitted to IOCL, IT IS VERY CONFUSING THAT WE ARE SAYING THAT SPRING SUPPORT AT NODE NUMBER 375 AND 345 NOT INCLUDED IN CALCULATION BUT BOTH SUPPORT IN OUR SUBMISSION MODEL AND TAKING LOAD.
AT NODE NUMBER 290 AND 440 RESTING IS PROPOSED INTIALY , SO THAT VALVE ASSEMBLY CAN BE REMOVED AT THE TIME OF MAINTAINANCE, BUT LATER ON DUE TO FOOTING ISSUE IT IS NOT WORKOUT BUT IT IS STILL THERE IN CALCULATION.
SYSTEM-3AS-BUILT SUPPORT ADDITION DELETION
₊Y & Guide GUIDE ₊Y & Guide GUIDE
₊Y RESTING ₊Y LIMIT STOP₊Y LIMIT STOP
SPRING NO NEED TO DELETE SPRING SPRING NO NEED TO DELETE SPRING
1. FOR GUIDE DEATIL REFER AKER SUPPORT STANDARD DOCUMENT REF. NUMBER G-11-7 AND G-11-6.2. FOR LIMIT STOP DEATIL REFER AKER SUPPORT STANDARD DOCUMENT REF. NUMBER LS-11-12.
TAKING LOAD ONY IN SUSTAINED CASE (KG)
In final model/report submitted to IOCL, IT IS VERY CONFUSING THAT WE ARE SAYING THAT SPRING SUPPORT AT NODE NUMBER 375 AND 345 NOT INCLUDED IN CALCULATION BUT BOTH SUPPORT IN OUR SUBMISSION MODEL AND TAKING LOAD.
AT NODE NUMBER 290 AND 440 RESTING IS PROPOSED INTIALY , SO THAT VALVE ASSEMBLY CAN BE REMOVED AT THE TIME OF MAINTAINANCE, BUT LATER ON DUE TO FOOTING ISSUE IT IS NOT WORKOUT BUT IT IS STILL THERE IN CALCULATION.
SYSTEM-3GLE SUPPORT REF. DOC. NO.
G-11-7-5G-11-7-5