View
219
Download
0
Category
Preview:
Citation preview
7/24/2019 Vol II (ICAR Audi Interior 2013)
1/50
INDIAN COUNCIL OF AGRICULTURAL
RESEARCH, NEW DELHI
TENDER AND CONTRACT DOCUMENT
Name of Work: Interior works including civil, electrical, acoustics etc. for
Auditorium at NASC Complex, Pusa, New Delhi.
TENDER NO.: RITES/CP/ICAR/Audi/Interior/2013
PART 2: FINANCIAL BID
August, 2013
(AGOVT.OFINDIAENTERPRISE)
RITESLIMITED
RITESBHAWANIIPLOTNO.144
SECTOR44Gurgaon122003,india
Tel(0124)2728305,fax(0124)2728371
7/24/2019 Vol II (ICAR Audi Interior 2013)
2/50
B SUB TOTAL OF ELECTRICAL WORKS (B)
GRAND TOTAL (A + B)
UNCONDITIONAL REBATE(IF ANY)
TOTAL OF ALL SCHEDULES
AFTER APPLYING REBATE
(RUPEES)
(i) In figures
(ii) In words.
i) SIGNATURE OF AUTHORIZED SIGNATORY OF TENDERER
ii) NAME OF SIGNATORY
iii) NAME AND SEAL OF TENDERER
iv) DATE
A SUB TOTAL OF CIVIL WORKS:
PART -II
FINANCIAL BID
SCHEDULE (BILL) OF QUANTITIES
Name of Work: Interior works including civil, electrical, acoustics etc. for Auditorium atNASC Complex, Pusa, New Delhi.
SUMMARY
S. NO. Description Amount (in fig) Amount (in words)
7/24/2019 Vol II (ICAR Audi Interior 2013)
3/50
S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu
(Rs.)
in figures in words
1.00 FLOORING
Note:
Wastage will not be payable extra in any of items.
Measurement of finished portion will be taken for
a ment.
Granite Flooring
1.01 Providing and laying 18 mm thick mirror finished
granite stone flooring, machine cut in required
size, approved shade, color and texture laid using
white cement slurry over 20 mm (average) thick
base of cement mortar 1:4 (1 cement : 4 coarse
sand) followed by laying, fixing and jointed with
white cement slurry mixed with matching pigment,
including rubbing and curing moulding and
polishing to edge to give high gloss finish etc
complete at all levels.(as approved)
1.01.1 Granite Type-A with Basic Rate 195/- sft FOR site Sqm. 2,342.00
1.01.2 Granite Type-B with Basic Rate 170/- sft FOR site Sqm. 586.00
1.02 Providing and fixing 18mm thick gang saw cut
mirror polished (premoulded and prepolished)
machine cut in risers of steps, skirting, dado and
pillars of approved shade, color and texture (as
approved) laid on 12 mm (average) thick cement
mortar 1:3 (1 cement 3 coarse sand) with joints
treated with white cement, mixed with matching
pigment, epoxy touch ups, including rubbing,
curing moulding and polishing to edge, if required
to give high gloss finish etc. complete at all levels
and as per direction of E-I-C.
1.02.1 Granite Type-A with Basic Rate 195/- sft FOR site Sqm. 953.00
1.02.2 Granite Type-B with Basic Rate 170/- sft FOR site Sqm. 238.00
Italian Marble Flooring, Skirting & Dado
1.03 Providing and fixing Italian marble in flooring,
skirting, wall dado etc as approved using 18mm
thick gang saw machine cut stone at all levels, of
required size & pattern and of approved shade,
color and texture laid using white cement slurry
over 20 mm thick base of cement mortar 1:4 (1
cement : 4 coarse sand) followed by laying, fixing
and jointing with white cement slurry mixed withmatching pigment, including rubbing, curing,
polishing, making mouldings of approved profile
and polishing of mouldings and edges to give high
gloss finish etc, complete at all levels and as per
direction of E-I-C.
1.03.1 Italian Marble Type-A (Light Emperador), Type-B
(Bottochino) & Type-C (Spanish Grey) in flooring
with Basic Rate Upto 250/- sft FOR site
Sqm. 1,343.00
BILL OF QUANTITIES
RATE (in Rs.)
NAME OF WORK:Interior works including civil, electrical, acoustics etc. for Auditorium at NASC Complex, Pusa, New Delhi
7/24/2019 Vol II (ICAR Audi Interior 2013)
4/50
S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu
(Rs.)
in figures in words
RATE (in Rs.)
1.03.2 Italian Marble Type-D (Dark Emperador), Type-E
(Perlato Sicilia) & Type-F (Grey William) in floor
with basic rate Upto Rs.340/- sft FOR Site
Sqm. 576.00
1.03.3 Italian Marble Type-A (Light Emperador), Type-B
(Bottochino) & Type-C (Spanish Grey) indado/wall with Basic Rate Upto 250/- sft FOR site
Sqm. 218.00
1.03.4 Italian Marble Type-D (Dark Emperador), Type-E
(Perlato Sicilia) & Type-F (Grey William) in
dado/wall with Basic Rate Upto 340/- sft FOR
site.
Sqm. 24.00
Composite/Engineered Marble Stone Counters
1.04 Providing and fixing 20 mm thick gang saw cut
mirror polished (premoulded and prepolished)
machine cut Composite/Engineered marble stone
for kitchen platforms, vanity counters ,window
sills, facias, skirting and similar locations ofrequired size of approved shade, color and texture
(as per approved sample) including laying by
using white cement slurry laid over 20mm thick
base of cement mortar 1:4 (1 cement : 4 coarse
sand) followed by all side joints treated with white
cement, mixed with matching pigment, epoxy
touch ups, including rubbing, curing, making
moulding and polishing to edge to give high gloss
finish etc. complete at all levels and as per
direction of E-I-C.
1.04.1 Composite Marble Type-A Sqm. 212.00
1.04.2 Composite Marble Type-B Sqm. 95.00
1.04.3 Composite Marble Type-C Sqm. 95.00
Vitrified & Ceramic Tile work
1.05 Providing and laying anti skid Ceramic floor tiles
600 x 600mm of minimum 9 mm thickness of 1st
quality of approved make in all colors, shades as
approved laid on 20mm thick cement mortar 1:4
(1 cement:4 coarse sand) fixed with "+" shaped 2
mm wide plastic spacers at corners (to be removed
before jointing) to achieve a perfectly straight joint
line, and jointed with Laticrete or approved
equivalent jointing compound of matching shade
complete as per direction of E-I-C.
Sqm. 868.00
1.06 Providing and laying vitrified floor tiles in
different sizes (thickness to be specified by the
manufacturer) with water absorption less than
0.08% and conforming to IS : 15622, of approved
make, in all colors and shades, laid on 20mm thick
cement mortar 1:4 (1 cement : 4 coarse sand),
including grouting the joints with white cement
and matching pigments etc., complete & as per
- -1.06.1 Size of Tile 600x600 mm Sqm. 390.00
7/24/2019 Vol II (ICAR Audi Interior 2013)
5/50
S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu
(Rs.)
in figures in words
RATE (in Rs.)
1.06.2 Extra for using "+" shaped 2 mm wide plastic
spacers at corners (to be removed before jointing)
during fixing of Vitrified tile in floor to achieve a
perfectly straight joint line, and jointed with
Laticrete or approved equivalent jointing
compound of matching shade in place of white
cement with matching pigment all complete as per - -
Sqm. 390.00
Wooden flooring
1.07 Providing and fixing minimum 11mm thick AC VI
grade laminated wooden flooring suitable for
commercial-heavy use areas like auditorium
application of approved make, shade and pattern.
The top surface shall have a 0.60 mm thick multi
layer high pressure laminate fixed over moisture
resistant high density fiberboard substrate. The
planks shall be of size 1200 mm x 200/125 mm.
The flooring shall confirm to EN 438, EN 717-1,
EN 13501-1, EN-1815, JIS Z 2801:2000
standards. The planks shall be placed on an
underlay of 0.2 mm thick alkali resistantPolyethylene sheet having density 920-935 kg/ m3
to resist moisture from the sub floor and to secure
the floor installation etc all complete. (Skirting
profiles, trims etc shall be included & not paid
extra) as per direction of E-I-C.
Sqm. 407.00
1.08 Providing and fixing 2090x205x30 mm thick
Activity plank flooring jointed with tongue and
groove joint having tensile strength of not less than
10 kg/sqm. Top layer consisting of woodloc (15
mm thick) supported on 6 mm HDF support
element & base of 9 mm thick foam
polytherne/polyether resilience element. Surface to
be treated with pre-lacquered with UV-curedpolyurethene/acrylic based lacquer free from
solvent & formaldehyde. Base of the floor consists
of two layers of 12mm thick water proof marine
ply, plywood bonded with phenolic resin with half
headless GI nails/steel screws wherever necessary,
with joints staggered with 2nd layer glued and
screwed to the first, fixed with wooden screws to
teakwood joists framework comprising 75x50mm
teakwood joist 900mm C/C in one direction and
50x50mm teak wood battens 400mm C/C on other
direction, teakwood joists resiliently supported on
150 x 150mm pads of 7.5mm nominal thickness of
waffle, neoprene pad ribbed (50 p.s.i. grade) and
50x50x6mm thick MS angle cleat fixed with
150mm long with 10mm dia GI bolts andexpansion fasteners, over floor slab at 900 x 900
Sqm. 341.00
Support locations including providing and
applying a coat of ready mixed aluminum primer
and a coat of synthetic enamel paint both of
approved brand and manufacturer over exposed
surfaces and edges of marine ply. The item
includes providing and fixing 145x50 mm
teakwood moulding as approved on the edges of
stage wooden flooring. Entire work shall be done
complete as per drawings, specifications and
directions of E-I-C. (Note : All teakwood shall be
certified kiln seasoned and treated against
7/24/2019 Vol II (ICAR Audi Interior 2013)
6/50
S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu
(Rs.)
in figures in words
RATE (in Rs.)
1.09 Providing & laying at site finished Bamboo
flooring (coffee shade) of approved make, color,
shade & finish of minimum 12 mm thickness and
of minimum size 960mm x 96 mm. The material
shall fulfill the following standards : Flammability
as per ASTM-E648 with Class-1 rating as per
NFPA, Smoke density as per ASTM-E622 shall be
less than 450 for flaming or non flaming mode,
compressive strength as per ASTM-D3501-86A
shall not be less than 52 MPa parallel to grain, 17
MPa perpendicular to grain & 116 MPa flat at
50% strain. Tensile strength as per ASTM-D3500-
90 shall not be less than 105 MPa parallel to grain,
Slip resistance coefficient of friction as per ASTM
D2047 shall be 0.71, Abrasion resistance weight
loss as per ASTM-C501 shall not be more than
350 gms (H-22 calibrated wheels loaded with 1000
gms weight at 70 RPM for 1000 cycles) and
Moisture content as per ASTM-D4442 oven dry
method shall not be more than 7.8%. (Skirting
profiles, trims etc shall be included & not paid
extra)
Sqm 272.00
Broadloom Carpet Flooring Type-A
1.10 Providing and fixing Carpet Flooring using
Broadloom (Roll type) carpet of approved make,
shade and pattern and of the following
specification: Tufted cut pile, 1/10 gauge with
100% Polyamide Millitron/ 6 Crealon (R) nylon/
SD Nylon pile or equivalent material having
minimum surface pile thickness of 5.3 mm and
minimum total thickness of 7.1 mm with Contract
Latex backing/ 'Weave back (R) backing/ Woven
Polypropylene backing, min. tufts of 201500 per
sqm and minimum total carpet weight of 2300
g/sqm, minimum pile yarn weight of 1200 g/sqm,
minimum surface pile density of 0.141 g/ cucm
having inbuilt anti-soiling protection, suitable for
commercial-heavy use areas like auditorium
application, having acoustical insulation value of
31 dB, CE labeled, EC certified, fulfilling Fire
Classifications EN 13501-1 euro class and
approved by Green Label Plus test for indoor
hygiene in standard length and width.
Sqm. 2,023.00
Tiled Carpet flooring Type-B
1.11 Providing and fixing Carpet flooring using CarpetTile of approved make, shade and pattern and of
the following specification: Loop pile carpet tile,
5/64 gauge of size 500 mm x 500 mm/ 610 mm x
610 mm with Minituft loop construction, 100%
Econyl Aquafil pile material/ Zeftron (R) yarn,
100% recycled solution dyed Nylon or equivalent
having minimum pile height of 0.8mm and
maximum total height of 6.5mm with secondary
backing of Back to Back modified bitumen,
Sqm. 732.00
7/24/2019 Vol II (ICAR Audi Interior 2013)
7/50
S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu
(Rs.)
in figures in words
RATE (in Rs.)
enhanced with a thermoplastic elastomer,
reinforced with a glass fiber fleece covered with
100% PES fleece including 10% recycled content/
non woven primary backing and secondary
backing of Nexterra (R) with min. 40% total
recycled content, minimum tuft density 190,000 /
sqm, minimum total carpet weight of 3,350 g/sqm, minimum pile weight of 480 g/ sqm, pile
above backing of minimum 176 g/ sqm, minimum
pile density of 0.220 g/ cucm, having minimum
impact noise rating of 10 dB suitable for
continuous use of castor wheel chairs as per EN
985 and fire resistance property as per EN 13501-1
and permanent anti-static 2 kV/ DOC FF-1-70,
static control
7/24/2019 Vol II (ICAR Audi Interior 2013)
8/50
S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu
(Rs.)
in figures in words
RATE (in Rs.)
2.01 Providing & applying Plaster of Paris (gypsum
anhydrous) suspended false ceiling up to any
height above floor level, including fixing of frame
work made of special sections, power pressed from
M.S. sheets and galvanized with zinc coating of
120 gms/sqm (both side inclusive). Consisting of
angle cleats of size 25 mm wide x 1.6 mm thickwith flanges of 27 mm and 37mm, at 1200 mm
centre to centre, one flange fixed to the ceiling
with dash fastener 12.5 mm dia x 50mm long with
6mm dia bolts. Other flange of cleat fixed to the
angle hangers of 25x10x0.50 mm of required
length with nuts & bolts of required size. The other
end of angle hanger fixed with intermediate G.I.
channels 45x15x0.9 mm running at the spacing of
1200 mm centre to centre, to which the ceiling
section 0.5 mm thick bottom wedge of 80 mm
with tapered flanges of 26 mm each having lips of
10.5 mm, at 450 mm centre to centre.
This shall be fixed in a direction perpendicular to
G.I. intermediate channel with connecting clips
made out of 2.64 mm dia x 230 mm long G.I. wire
at every junction, including fixing perimeter
channels 0.5 mm thick 27 mm high having flanges
of 20 mm and 30 mm long, the perimeter of
ceiling fixed to wall/partition with the help of rawl
plugs at 450 mm centre, with 25mm long dry wall
screws @ 230 mm interval and reinforced with
rabbit wire mesh of 100mmx16mm gauge fixed to
2.01.1 Flat surfaces Sqm. 1,180.00
2.01.2 Curved surfaces Sqm. 128.00
Gypsum Board False Ceiling2.02 Providing and fixing false ceiling at all height
including providing and fixing of frame work
made of special sections, power pressed from M.S.
sheets and galvanized with zinc coating of 120
gms/sqm (both side inclusive) as per IS : 277 and
consisting of angle cleats of size 25 mm wide x 1.6
mm thick with flanges of 27 mm and 37mm, at
1200 mm centre to centre, one flange fixed to the
ceiling with dash fastener 12.5 mm dia x 50mm
long with 6mm dia bolts, other flange of cleat
fixed to the angle hangers of 25x10x0.50 mm of
required length with nuts & bolts of required size
and other end of angle hanger fixed with
intermediate G.I. channels 45x15x0.9 mm running
at the spacing of 1200 mm centre to centre, towhich the ceiling section 0.5 mm thick bottom
wedge of 80 mm with tapered flanges of 26 mm
each having lips of 10.5 mm, at 450 mm centre to
centre.
(Nothing extra shall be paid for openings for
grilles, electrical fixtures etc. and vertical/inclined
face shall be measured above 200mm high only).
2.02.1 12.5 mm thick tapered edge gypsum fire resistant
board conformin to IS: 2095- Part I
Sqm. 1,015.00
7/24/2019 Vol II (ICAR Audi Interior 2013)
9/50
S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu
(Rs.)
in figures in words
RATE (in Rs.)
2.02.2 12.5 mm thick tapered edge gypsum moisture
resistant board.
Sqm. 85.00
2.02.3 Specification same as above but for providing &
fixing of 25mm (2 layers of 12.5mm) Gypsum
board (moisture resistant) fixed on galvanized steel
framework. All framework suspension system asper manufacturer specification as required to
withstand the load. The parimeter channel to be
screw fixed to brick/concrete wall with rawl plugs
and screws. The lower level of Gypsum board to
have joints over frame and to be fixed at max.
300mm c/c, to the frame and second layer have
staggered joints and to be fixed to the first layer.
All joints to be taped with paper tape and filled
with jointing compound to provide smooth
surface, Entire work to be done as per
specifications including painting two coats of
primer and as per directions of E-I-C.
Sqm. 4,953.00
2.02.4 Extra for fixing Gypsum Board False Ceiling in
Zigzag Profile (As per Drawing in Auditorium
area
Sqm. 2,129.00
2.02.5 Fully Perforated Gypsum Plaster Board of size
1200 x 2400x12.5 mm having approx. 15 %
perforated area with perforation size and pattern as
approved and as per manufacturer's specification,
with all 4 side tapered and backed by acoustical
tissue with NRC value not less than 0.60
Sqm 1,428.00
2.02.6 Providing & fixing thermal insulation of ceiling
with Resin Bonded Fiber glass wool conforming to
IS : 8183, density 24kg / m3, 50mm thick,
wrapped in 200 gms virgin polythene bags/jute
bags, fixed to ceiling with metallic cleats
(50x50x3 mm) @ 60 cm and wire mesh of 12.5
mm x 24 gauge wire mesh. (above gypsum board
Sqm 2,170.00
2.03 Providing and fixing tiled false ceiling of approved
materials of size 595x595 mm in true horizontal
level, suspended on inter locking metal grid of hot
dipped galvanized steel sections (galvanized @
120 grams/sqm, both side inclusive) consisting of
main "T" runner with suitably spaced joints to get
required length and of size 24x38 mm made from
0.30 mm thick (minimum) sheet, spaced at 1200
mm center to center and cross "T" of size 24x25
mm made of 0.30 mm thick (minimum)sheet,
1200 mm long spaced between main "T" at 600mm center to center to form a grid of 1200x600
mm and secondary cross "T" of length 600 mm
and size 24x25 mm made of 0.30 mm thick
(minimum) sheet to be interlocked at middle of the
1200x600 mm panel to form grids of 600x600 mm
and wall angle of size 24x24x0.3 mm and
7/24/2019 Vol II (ICAR Audi Interior 2013)
10/50
S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu
(Rs.)
in figures in words
RATE (in Rs.)
laying false ceiling tiles of approved texture in the
grid including, required cutting/making, opening
for services like diffusers, grills, light fittings,
fixtures, smoke detectors etc. Main "T" runners to
be suspended from ceiling using GI slotted cleats
of size 27 x 37 x 25 x1.6 mm fixed to ceiling with
12.5 mm dia and 50 mm long dash fasteners, 4mmGI adjustable rods with galvanised butterfly level
clips of size 85 x 30 x 0.8 mm spaced at 1200 mm
center to center along main T, bottom exposed
width of 24 mm of all T-sections shall be pre-
painted with polyester paint, all complete for all
heights as per specifications, drawings and as
directed by Engineer-in-charge.
2.03.1 12.5 mm thick square edge PVC Laminated
Gypsum Tile of size 595x595 mm, made of
Gypsum plasterboard, manufactured from natural
gypsum as per IS 2095 part I and laminated with
white 0.16mm thick fire retardant PVC film on the
face side and 12micron metalized polyester on the
back side with all edges sealed with the face sidePVC film which goes around and wraps the edges
and is bonded to the edges and the back side
metalized polyester film so as to make the tile a
completely sealed unit.
Sqm. 687.00
2.04 Acoustic Ceiling Tiles
2.04.1 Providing and Fixing Acoustic tiles of 15 mm
thickness and tegular edge, easily demountable
tile, manufactured from High density glass wool,
with the visible surface batch painted glass tissue
in white and the back of the tile should be
covered with glass tissue. The glass wool core of
the tiles should be tested and classified as non-
combustible according to prEN ISO 1182. Thesystem should have Sound Absorption NRC value
of 0.9 (according to ASTM C 423). Tiles should
withstand a permanent ambient RH Upto 95% at
30*C without sagging, warping or delaminating
(ISO 4611). The light reflectance of the tiles
should not be less than 83%. Tiles certified by the
indoor climate labeling and recommended by
Swedish asthama and allergy association and
granted Nordic Swan ecolabel and fully
recyclable. The glass wool core of the tiles should
be tested and classified as non combustible
according to EN ISO 1182 and the ceilings should
fall under Class A2 s1 d0 according to EN 13501
1.
Sqm. 837.00
7/24/2019 Vol II (ICAR Audi Interior 2013)
11/50
S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu
(Rs.)
in figures in words
RATE (in Rs.)
2.04.2 Providing and Fixing Acoustic tiles of 20 mm
thickness natural square edge, easily demountable
tile, manufactured from High density glass wool,
with the visible surface is a matt blackbatch
painted glass tissue and the back of the ti le should
be covered with glass tissue. The glass wool core
of the tiles should be tested and classified as noncombustible according to prEN ISO 1182. The
system should have Sound Absorption NRC value
of 0.9 (according to EN ISO 11654). Tiles should
withstand a permanent ambient RH Upto 95% at
30*C without sagging, warping or
delaminating (ISO 4611). The light reflectance of
the tiles should not be more than 3- 4 %.
Sqm. 259.00
Wooden False Ceiling
2.05 Providing and Fixing Wooden false Ceiling
comprising of a Galvanized MS frame as required
covered with 12 mm thick Marine ply, followed by
6 mm premium quality MDF for making groove
and finished with a natural veneer (as approved) of
3.5 mm thickness duly Spirit polished with
melamine matt coating. The ceiling shall be fixed
to the roof soffit with adequate suspenders. The
item shall be inclusive of cutting & making
cutouts for lights, diffusers etc all complete.
(veneer with basic cost Upto Rs:100 per sft FOR
site)
Sqm. 405.00
Perforated Metallic ceiling Type-B: Clip in Tile
2.06 Providing & installing Clip in tiles/plank ceiling
made out of Aluminum. The ceiling tiles shall bein size of 600x600x0.7mm (thk), perforated to L15
pattern (2.5mm diameter holes, 16% opening) with
Soundtex Tissue laminated at the back, beveled
edges on 4 sides, clipped into secondary clip in
profiles at 600mm c/c. The clip-in profiles shall be
cross connected to C-channel primary through
threaded rod hangers spaced at 1200mm c/c.
Finish of ceiling tiles:RAL 9016 white polyester
powder coat finish with minimum 60 microns
paint thickness or as approved.
Sqm. 634.00
2.07 LINEAR BAFFLE CEILING
Providing & installation of approved quality
vertical linear baffle ceiling made out of folded
Aluminum. The baffle units shall be in size of
50mm (W) x 150mm (H) and 1000mm x 4500mm
x 1mm (thk), non-perforated. The ceiling baffle
units shall be installed at a distance of 300mm c/c
in one direction. The baffle units shall be attached
to C-channel carriers spaced at 1200mm c/c. The
C-channel carriers shall then be cross connected to
perforated L-angle primary grid and suspended
with M6 threaded rod hangers spaced at 1200mm
7/24/2019 Vol II (ICAR Audi Interior 2013)
12/50
S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu
(Rs.)
in figures in words
RATE (in Rs.)
2.07.1 Baffles finished with RAL 9016 selected wood
grain with minimum 60 microns paint thickness.
Sqm. 298.00
2.07.2 Baffle finished with RAL 9016 polyester powder
coat with minimum 60 microns paint thickness.
Sqm. 444.00
2.08 WOODEN PLANK CEILING (NON-
PERFORATED & PERFORATED)
2.08.1 Providing & installing of approved quality timber
effect Ceiling Highlighter panels hook-on ceiling
made out of fire rated MDF core material. The
ceiling panels shall be in size of 600x1200x16mm
thk (Non Perforated panels surfacesPanels and
support grids to be used as a proprietary system
from a single source manufacturer and shall be
produced in accordance to metal ceiling industry
standard TAIM (Technical Working Group of
Industrial Metal Ceiling Manufacturers). Panels
tolerances shall be according to +/- 2.0mm on
width and length of panels. Panels deflection shall
be allowable up to L/360.surface. The ceiling
planks shall be with square edges on 4 sides,
hooked along the length . The hook on profiles
shall then be cross connected to perforated L-
angle primary grid and suspended with M6
threaded rod hangers spaced 1200mm C/C. Finish
of ceiling panels shall be Timber effect melamine
wooden finish.
Sqm. 20.00
2.08.2 Providing and installation of timber effect
melamine finish hook-on ceiling made out of fire
rated MDF core material. The ceiling panels shall
be in size of 600x1200x16mm (thk), perforated
to 3mm diameter holes, 16mm c.c at front &
10mm dia holes @ 16mm C/C at the back. There
will be a layer of Soundtex tissue laminated at the
back of ceiling panels. The ceiling planks shall be
with square edges on 4 sides, hooked along the
length . The hook on profiles are then cross
connected to perforated L- angle primary grid and
suspended with M6 threaded rod hangers spaced
1200mm C/C complete with all arrangement and
as per direction of E-I-C. Finishes of ceiling
panels: Timber effect Melamine finish.
Sqm. 10.00
MICRO-PERFORATED METAL CEILING
TYPE-A: 2D CEILING
7/24/2019 Vol II (ICAR Audi Interior 2013)
13/50
S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu
(Rs.)
in figures in words
RATE (in Rs.)
2.09 Providing & Installation of Metal Ceiling micro-
perforated with fleece backing. The ceiling panels
shall be in customized sizes to provide 2D effect,
micro- perforated with Soundtex acoustic fleece
L15 pattern (1.5mm diameter holes, 22% opening
approx). The ceiling planks shall be with square
edges on 4 sides, hook onto secondary hook onprofiles. The hook on profiles are then cross
connected to perforated L-angle primary grid and
suspended with M6 threaded rod hangers spaced
1200mm C/C. and providing and laying 50mm
thick resin bonded glass wool (24 kg /m3) over
perforated ceiling planks.
Finishes of ceiling tiles/ planks: RAL 9016 white
polyester powder coat finish with minimum 60
microns paint thickness or as approved and as per
dirction of E-I-C.
Sqm. 755.00
OPEN CELL CEILING
2.10 Providing and installation of approved quality
linear cell ceiling made out of 0.5 mm thick
Aluminum. The assembled cell ceiling panels shall
be made out of main blades in 15mm (W) x 40mm
(H) in 1200mm (L), installed at 200 mm c/c. and
cross connected to secondary blades in 15mm(W)
x 40mm(H) in 600mm(L) with 100 mm pitch. The
assembled cell ceiling panels shall be clipped into
U-94 carriers in GMS, pre-coated in black
enameled finished at 1200mm c/c. Wire clips shall
hold the cell ceiling panels into the U-94 carriers.
The Primary angles made out of GMS, type U1040
are cross connected to the U-94 carriers at
1200mm c/c., for lateral bracing the whole ceiling
shall be suspended by M6 threaded rods. All panelmodules must be hinge able through wire clips &
grid should not be visible from bottom. Black
soundex tissue to be pasted at the back of the
panels to block visibility of internal service piping
installed on ceiling.
Finish of cell ceiling panels: Metallic silver in
RAL 9006/White in RAL 9016/Natural Aluminum
finish (Black or as approved). including Providing
and installation of 50mm thick resin bonded glass
wool (24 kg/cum)with GI frame fixed on roof slab
with frame held on 24G x 10 GI wire mesh
covered with black jute fabric over open Cell
Metal Ceiling.
Sqm 2,236.00
STEEL WIRE ROPE HANGERS &
SUPPORTS:
2.11 Supply, Fabrication, installation and testing of all
false ceiling with Wire Rope Hangers & Supports
complete with end fixing in accordance with the
approved shop drawings and as required by the
specifications.
2.11.1 Taking working load Upto 45 kg Nos 2,167.00
2.11.2 Taking working load 46 to 90 kg Nos 271.00
7/24/2019 Vol II (ICAR Audi Interior 2013)
14/50
S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu
(Rs.)
in figures in words
RATE (in Rs.)
2.11.3 Taking working load 91 to 225 kg Nos 271.00
3.00 SPECIALIZED ITEMS
3.01 SLIDING FOLDING PARTITION
3.01.1 Sound Barrier Partition above Operable
Sliding/Folding Partition (Audi (S.F.),
Multipurpose Dining (G.F.) and Training Rooms
G.F.
Sqm 468.00
Providing and fixing to the required profile and
shape 2 layers of 12.5mm thick Gypsum board (on
both sides of barrier) on GI framework comprising
40x40x18G tubular frame painted with red oxide
anti corrosion paint 610x610mm centre to centre
fixed on Roof Structure with 40x40x5 MS
galvanised cleat, 100mm long 1200 c/c and ceiling
framework with welded connections. The Gypsum
board (on both sides of barrier) to be backed with
50mm thick resin bonded fiber glass insulation (24kg/cum) cut to size and inserted in GI framework
and held in place with 28G x 12mm GI wire
netting. The first layer of Gypsum board to have
joints over frame and second layer of Gypsum
board to have joint staggered with respect to the
first layer, all joints between board in both layers
to be taped with paper tape and filled with sealing
compound.
Gypsum board layer to be sealed at junction with
Roof sheeting/ structure and false ceiling below
with the non-hardening mastic compound, so as to
provide smooth surface. Entire work to be done as
per drawing, specifications and directions as perE
I-C.
3.01.2 Operable Acoustic Partitions (Type 1)- Audi
(S.F.), Multipurpose Dining (G.F.) (One side
perforated) with openable and foldable doors
alongwith complete arrangement and fittings
required and as per the drawings.
7/24/2019 Vol II (ICAR Audi Interior 2013)
15/50
S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu
(Rs.)
in figures in words
RATE (in Rs.)
Supply and installation of operable acoustical
partitions in designated area comprising individual
panels100mm thick and maximum 1200mm wide
Panels shall be of all steel construction and shall
fully enclose and protect all edges of surface
material with protective edge trim. Panel skins
shall be Steel class A rated as per ASTM E84laminated to steel structure and acoustical backing,
mounted in full aluminium profile perimeter
protective frames, Panels shall have one face
perforated with 33% open perforated steel and
underlay sound control blanket and septum
providing 0.65 NRC. Vertical sound seals between
panels shall be tounge and groove configuration
incorporating vinyl acoustical seals Panel weight
shall not exceed 55 kg/sqm. Panels shall be
suspended from roll-formed steel track system
suspended from steel supports by threaded rods.
Each panel shall be top supported by two trolley
assemblies comprising steel ball bearing wheels.
Partitions to be complete, finished with fire
retardant fabric in both side num finish (Black oras a
Panels shall have operable top and bottom seals
simultaneously operated by a removable handle.
The seals shall not contact floor or track during
movement of panels. Panels shall also feature
horizontal seals for stabilization and acoustic
performance. Final partition closure to be
accomplished by lever closure panel of same
construction as basic panel but provided with an
expanding jamb operated by a removable handle.
The partition shall have been tested by an
independent acoustical laboratory and shall have
weighted SRI (Rw) of at least 51 in accordance
with ASTM E90/DIN 52210. After installation,
operable partition shall be tested by manufacturer
in presence of client's representative and
consultant. Noise reduction measurements shall be
made in accordance with ASTM E336. NIC shall
be calculated as per ASTM E413. Noise reduction
shall meet NIC 51. Entire work to be done
complete as per drawings, specifications and
direction of E-I-C
3.01.2.1 Operable Acoustic Partitions (Type 1)- One side
perforated with Automatic seal for Audi (S.F.)
with i/c fittings & openable and foldable doors
alongwith complete arrangement and fittings
required and as per drawings.
Sqm 456.00
3.01.2.2 Operable Acoustic Partitions (Type 1)- One side
perforated with Automatic seal for Multipurpose
Dining (G.F.) with openable and foldable doors
alongwith complete arrangement and fittings
required and as per the drawing.
Sqm 141.00
7/24/2019 Vol II (ICAR Audi Interior 2013)
16/50
S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu
(Rs.)
in figures in words
RATE (in Rs.)
3.01.3 Operable Acoustic Partitions (Type 2)
Training rooms (G.F.) (Without perforation) with
openable and foldable doors alongwith complete
arrangement and fittings required and as per the
drawing.
Sqm 165.00
Supply and installation of operable acousticalpartitions in designated area comprising individual
panels 100mm thick and maximum 1200mm wide
Panels shall be of all Steel construction and shall
fully enclose and protect all edges of surface
material with protective edge trim. Panel skins
shall be of MDF Board (good quality Exterior
Grade) laminated to steel structure and acoustical
backing, mounted in full aluminium profile
perimeter protective frames. Vertical sound seals
between panels shall be tounge and groove
configuration incorporating vinyl acoustical seals
Panel weight shall not exceed 55 kg/sqm. Panels
shall be suspended from roll-formed steel track
system suspended from steel supports by threaded
rods. Each panel shall be top supported by twotrolley assemblies comprising steel ball bearing
wheels. Partitions to be complete with Veneer in
both sides as per approved sample (with a base
rate of Rs. 200 Per Sqft).
Panels shall have operable top and bottom seals
simultaneously operated by a removable handle.
The seals shall not contact floor or track during
movement of panels. Panels shall also feature
horizontal seals for stabilization and acoustic
performance. Final partition closure to be
accomplished by lever closure panel of same
construction as basic panel but provided with an
expanding jamb operated by a removable handle.
The partition shall have been tested by an
independent acoustical laboratory and shall have
weighted SRI (Rw) of at least 51 in accordance
with ASTM E90/DIN 52210. After installation,
operable partition shall be tested by manufacturer
in presence of clients representative and
consultant. Noise reduction measurements shall be
made in accordance with ASTM E336. NIC shall
be calculated as per ASTM E413. Noise reduction
shall meet NIC 51. Entire work to be done
complete as per drawings, specifications and
direction of E-I-C.
3.02 SS HANDRAIL
7/24/2019 Vol II (ICAR Audi Interior 2013)
17/50
S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu
(Rs.)
in figures in words
RATE (in Rs.)
3.02.1 Supply and installation of modular and component
(Weld free) based system of satin finish stainless
steel AISI 304 SS handrail and balustrade system
having minimum 38mm dia tube handrail (1.5mm
thickness) (app weight 1.5 kgs per Rmt) handrail
connected with unified stem keys in bead blasted
finish to 12X54 mm stain free finish solid (approxweight 7.5 to 7.7 Kgs) flat vertical member to be
fixed on the side of staircase (2-point fixed) with
circular solid bosses of 50 mm dia at max c/c
distance of 1800 mm with anchor fasteners to the
wall having infill of minimum 10 mm thick
toughened glass complete with all necessary bends
and termination. Ht. 900-1000 mm. System as per
tested and recommended by BS certification of BS
6180:1995 from British Standard Institute and as
per MTC. Rate for the complete unit is payable in
running meter and includes Handrail Tube,
Uprights Solid, unified Cherry/Maple key,
Toughened glass etc, including installation and
making good the floors if required as per direction
of E-I-C.
Rmt 102.00
3.03 WATER CURTAIN: Nos 2.00
Providing & installation of water curtain as per the
specification mentioned below including material
as listed below. Job includes preparation of Shop
Drawing & installation etc all complete:
Inclusions:
NOZZLES: Supply of 304 Gr Stainless Steel
manifold having 130 nos brass spray nozzles
(MOC GM/Brass) complete with bottom tieing
support, clear strings as required. (1 No for each
fountainLIGHTS
a) Supply of 24V DC, 5x1 W LED linear light,
(WW)color under water luminary with wide beam
super magnifying lense (MOC Al) Protection
Index IP 68. (7 No for each fountain)
b) Supply of ABS Casing for 5 X 1 W LED Lights.
(7 No for each fountain)
c) Supply of Waterproof joints. (7 No for each
fountain)
d) Supply of constant voltage LED driver input
AC 220-250 volts, output 24 V DC. (1 No for each
fountain
PUMPS: Supply of prefilter basket pump set
delivering. Body made in glass loadedpolypropylene, impeller in PPO, mounting seal in
glass loaded polyamide, motor shaft in stainless
steel AISI 420, mechanical seal in graphite and
steatite, motor housing in AL L 2521, protection
index IP 55, single phase built in thermal
rotection 1 no for each fountainDOSING PUMP UNIT: Supply of online
Chlorine Dosing injector with mechanical
connections complete as required. (1 no for each
fountain .MULTI MEDIA SAND FILTER
7/24/2019 Vol II (ICAR Audi Interior 2013)
18/50
S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu
(Rs.)
in figures in words
RATE (in Rs.)
a) Providing of FRP pressure High rate Sand
Filter for filtration of suspended material from
water body complete with six position multiport
valve for filter,backwash,rinse,waste ,recirculate
and close all flow to pool the filter body
manufactures in fiber glass with uV .resistance
surface provided with oil pressure gauge cap 19.5cum/hr, 700 mm dia filter pressure 2.5 Kg/sqcm.
b) Supply of Silica sand for filter with
granulometry between 0.4-0.8 mm. (210 kg (app)
for each fountain)
ELECTRICAL CONTROL PANEL:Supply of
Cubical Control Panel made of 16 gauge CRC
sheet powder coated with Starter, Single phase
prevention, MCB, TP MCB's, Protection circuits
etc and space for CVD for the lights. (1 Set for
each fountainu PVC PIPING: Providing and fixing uPVC
pipes (10kg. Pressure) including accessories &
fittings as required (Elbow, MTA, End cap,
Socket, Tee, Reducing Tee etc.) (1complete job foreach fountain)
SUPPLY OF BALL VALVES WITH
FITTINGS AS REQUIRED.
a) Supply of Anti vortex complete as required.
(1no for each fountain)
b) Supply of 63 mm dia uPVC ball valves. (3 no
for each fountain)
c) Supply of 50 mm dia Gun Metal Non Return
Valve. (1no for each fountain)
CABLE & CONDUITING: Supply of double
sheated cables of various sizes including
accessories etc required (PVC Conduit, PVC
Bend, Steel wire, etc.) for final equipment
connections with control anel.a) Three Core copper double sheated submersible
cable(Motors) with conduit. (1 complete job for
each fountain)
b) Wire 1.5mm Three Core round flexible sheathed
insulated( Lights) (1 complete job for each
fountain
3.04 Retractable Seating Nos 384.00
Providing & installation of retractable seating
system with the specification as mentioned below:
Maximum Hall multifunctionally automatic
system based on retractable risers with folding &
unfolding mechanism. Telescopic risers ensures
optimal sight from any position. Electric traction
mechanism & pneumatic seat folding & unfoldingsystem. Safety equipped with a device that blocks
the movement of riser if there are obstracles in
their run. Maintanence & durability: Chairs are
protected against all external agents when not in
use. & simultaneous configuration of risers &
access stairs protects the risers also. Depending
upon the type of chairs used the riser height can
vary between 320 to 450 mm.
7/24/2019 Vol II (ICAR Audi Interior 2013)
19/50
S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu
(Rs.)
in figures in words
RATE (in Rs.)
Chairs have center to center dimension of 500
mm, Beam mounted 3 to 4 chairs, 150 mm upright
position profile, upholstry system consisting of a
single block with internal structure & inherent fire
retardant fabric & foam Ergonomic & keep shape
single block covered with easily changeble zip-ion
upholstery. Soft system, silent cushinoned tip upsystem for seat, backrest & armrest prevents any
bump or annoying sounds. maintanence free
gravity folding mechanism & product should
comply with international fire regulation.The
seating should be as per the drawing and complete
drawing alongwith the details is to be provided
and get approved by E-I-C for complete
functionary of the system.The rate should include
complete system installation and all statutory
application taxes warranty tests etc.
4.00 WALL FINISHES
Note:
1) All unprotected surfaces of wood, MDF, Ply etc.
shall be treated with anti-termite paint, fire
retardant moisture resistant & black Japan
protective paint coatings.
2) All wood work shall be dry and moisture
content should be within permissible limit.
4.01 Providing & applying 4 mm thick (avg) P.O.P.
punning (calcium sulphate semi-hydrate variety)
over old / new wall surface by hacking of the
existing surface for proper bond including
rounding and chamfering of corners and junctions
and providing and fixing M.S. angle beading atcorners wherever required to give a smooth surface
true in line and plumb including making grooves
as per design. This item includes scaffolding,
protection of adjoining surfaces & cleaning etc.
complete and as per direction of E-I-C.
Sqm. 6,102.00
4.02 Wall Paneling
4.02.1 Base Frame for paneling
4.02.1.1 Providing & fixing base frame of 50x 50 mm
Marandi Wood treated with anti termite chemical
and fire retardant paint of approved maker,
provided at an average spacing of 600mm c/c both
ways adequately to the wall in line and plumb with
the help of wooden plugs and screws fixed to wall& tightened etc all completeas per direction of E-I-
C
Sqm 178.00
7/24/2019 Vol II (ICAR Audi Interior 2013)
20/50
S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu
(Rs.)
in figures in words
RATE (in Rs.)
4.02.1.2 Providing and fixing structural steel frame (for
cladding of wooden partitions/Paneling) on walls
at all heights using Galvanized M.S. square/
rectangular tube in the required pattern as per
architectural drawing, including cost of cutting,
bending, welding etc. The frame work shall be
fixed to the wall with the help of Galvanized M.S.brackets/ lugs of angle iron/ flats or anchor
fasteners etc. which shall be welded to the frame
and embedded in brick wall with cement concrete
block 1:2:4 (1 cement :2 coarse sand :4 graded
stone aggregate 20 mm nominal size) of size
300x230x300 mm, including cost of necessary
centering and shuttering and with approved
expansion hold fasteners on CC/RCC surface,
including drilling necessary holes.
Kg 21,284.00
4.02.2 Providing and fixing thermal insulation with Resin
Bonded Fibre glass wool conforming to IS: 8183
having density 24 kg/m3, 50 mm thick, wrapped
in 200G Virgin Polythene Bags fixed to wall withscrew, rawel plug & washers and held in position
by criss crossing GI wire etc. complete as per
directions of Engineer-in-Charge.
Sqm. 6,091.00
Veneer Finished Paneling Type-A & B:
4.02.3 Providing and fixing Veneer finished wooden wall
paneling in portals & frames (as per drawing &
approval), Panels of 6 mm MDF board cold
pressed with 3.5 mm thick natural wood veneer
duly Spirit polished and melamine matt coat in
design and pattern as per drawings & as approved
fixed over a sub strata of 12 mm thick MDF board
duly screwed to the base frame. The panels shallbe fixed leaving a precise gap of 10 mm between
two panels. The sides of frame touching the
masonry will be painted with black Japan. (Base
Frame to be paid in respective Item). (Basic Rate
of Veneer=RS.100/- per sft FOR site)
Sqm. 1,529.00
Metallic Laminate Paneling Type-A & B:
4.02.4 Providing and fixing Metallic Laminate finished
wooden wall paneling with 6 mm thick MDF
board cold pressed with SS Metallic Laminate (1.5
mm thick) of approved shade and make in design
and pattern as per drawings fixed over a sub strata
of 12 mm MDF board duly screwed to the baseframe. The panels shall be fixed leaving a precise
gap of 10 mm between two panels. The sides of
frame touching the masonry will be painted with
black Japan. (Base Frame to be paid in respective
Item). (Basic Rate of SS Metallic
Laminate=RS.140/- per sft FOR site)
Sqm. 170.00
7/24/2019 Vol II (ICAR Audi Interior 2013)
21/50
S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu
(Rs.)
in figures in words
RATE (in Rs.)
4.02.5 Providing & Fixing of Panels of 12.5 mm thk
Gypsum board screwed to the wooden/Galvanized
MS base frame over 6 mm thk. MDF and finished
with paper tape, joining compound and top coat of
primer as required. (Base Frame to be paid in
respective Item)
Sqm. 82.00
4.02.6 Providing & Fixing of Panels of 12 mm thk MDF
screwed to the wooden/Galvanized MS base frame
as per drawings and finished with top coat of anti-
termite paint and as required. (Base frame to be
aid in res ective item
Sqm. 1,603.00
4.02.7 Providing & Installation of Panels of 17 mm thk
Superior Quality MDF Routed as per design
screwed to the wooden/Galvanized MS base frame
over 6 mm thk. MDF as per drawings and finished
as approved. (Base Frame & finishing to be paid in
respective Item)
Sqm. 387.00
4.02.8 Extra for finishing the Routed MDF panels with:
4.02.8.1 High Gloss Automotive paint as per the approved
sam les.
Sqm. 349.00
4.02.8.2 High Gloss Spray Enamel Paint as per the
approved samples.
Sqm. 39.00
4.02.9 Acoustic Lattice Paneling Type-A, B & C:
Providing and fixing (American Walnut or as
approved) finished Acoustical Lattice wooden wall
paneling consisting of base frame treated with antitermite chemical of approved make. Panels to be
installed as per specification. The Timber
melamine effect acoustic wall panels made out of
Fire Rated MDF core material. The acoustic wall
panels shall be in size of 128x2440x18mm (thk).
The back of timber melamine panels shall be
laminated with Soundtex black acoustic tissue to
provide NRC not less than 0.8. The acoustic
timber wall panels shall be with tongue and groove
detailing along the length of panels, with square
edges on 2 sides along the width of panels. The
wall panels shall be clipped into aluminum
channels and clips Keel and Fastener system at
600mm c.c. Density -800kg /m3, R.H 70, Fire
Rated Euro Class B and C formerly Class 0 andClass 1 BS476 part 6 and 7 respectively.
4.02.9.1 Perforated panels having perforation to 25/30 mm
diameter holes, at 32/35 mm c/c at the back face,
and front of the panels to have cut with grooves of
3mm at 16mm c/c.
Sqm. 835.00
4.02.9.2 Non-perforated panels at back & front of the
panels to have cut with grooves of 3mm at 16mm
c/c.
Sqm. 377.00
Fabric Finished Panels
7/24/2019 Vol II (ICAR Audi Interior 2013)
22/50
S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu
(Rs.)
in figures in words
RATE (in Rs.)
4.02.10 Fabric Finished Acoustic Panels Type-A, B &
C:
4.02.10.1 Providing & Installing of fire retardent Fabric
finished Wall Panel having minimum 40 mm thick
High density glass wool with natural square edge
(Size: 600*600 minimum or as approved),
installed with concealed grid Hook on system anddemountable panels. Wall brackets 50*50*75 mm
& 2.8 mm thick shall be installed @ 1200 mm c/c
for installation of panels. Panels shall be
manufactured from High density glass wool with
visible surface as a glass fiber fabric and the back
of the tile covered with glass tissue. The glass
wool core of the tiles shall be tested and classified
as non combustible according to prEN ISO 1182.
The system should have Sound Absorption NRC
value of 0.9 (according to EN ISO 11654). Tiles
should withstand a permanent ambient RH Upto
95% at 30*C without sagging, warping or
delaminating (ISO 4611).
Sqm. 2,008.00
4.02.10.2 Fabric Finished Wood Wool Acoustic Panels
T e-D:
Providing and fixing fire retardent fabric on 6mm
PU foam over 25mm thick wood wool cement slab
as per approved sample and shade on framework
with supports. The wood wool slabs shall be
backed with 50mm thick resin bonded glass wool
(24kg/m3) cut to size and inserted in framework
and held in place with 28Gx12mm GI wire netting.
Fabric shall be stretched flat on PU foam over
wood wool cement slabs and fixed with rubber
adhesive and screws complete including fixing of
20x6mm teakwood beading over wall paneling,
size and pattern as per drawings. All beading shall
be wax polished after filling wood filler and sand
papering to smooth finish. Entire work shall be
done as per drawings, and as directed. (Basic cost
of fabric Upto Rs. 1200/meter). (GI/MS base
frame will be paid in the respective item)
Sqm. 225.00
4.02.10.3 Fabric Finished Non-Acoustic panels Type-E:
Providing and fixing fire retardent fabric on 6mm
thk PU foam over 12mm thick marine ply as per
approved sample and shade on the framework
600x600mm centre to centre (max.), fixed to wall
surface. Fabric to be stretched flat on PU foam
over marine ply and fixed with rubber adhesiveand screws complete including fixing of 20x6mm
teakwood beading over wall paneling, size and
pattern as per Architect. All beading to be wax
polished after filling wood filler and sand papering
up to smooth finish. Entire work to be done as
per drawings, specifications and direction of E-I-
C.(Basic cost of fabric Upto Rs. 1200/meter).
(GI/MS base frame will be paid in the respective
item)
Sqm. 321.00
4.02.11 Light Weight Sound Insulating partition
7/24/2019 Vol II (ICAR Audi Interior 2013)
23/50
S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu
(Rs.)
in figures in words
RATE (in Rs.)
4.02.11.1 Providing and fixing wooden Partition 150 mm
thick including base frame of red oxide anti
corrosion paint MS Tube as per requirement
treated with anti corrosive red oxide of approved
make, provided at average 600mm c/c both ways
fixed to wall with dash fasteners and covered with
12 mm thick Marine ply of approved make onboth side, followed by 6 mm thick superior grade
MDF & finished with 3.5 mm thick Veneer duly
Spirit polished with melamine matt coating with
desired finishing. Grooves of approved size to be
provided at joints.
Sqm 10.00
4.02.11.2 Providing and fixing sound insulating partition,
122mm thick, comprising 25mm thick Gypsum
Board (each individual layer built up with 2 layers
12.5mm Gypsum Board) fixed on one side of
galvanized 98x50x18G studs, 1220mm c/c frame.
Frame members fixing system to be as per
manufacturer. Cavity of the frame behind Gypsum
boards to have 50mm thick fiber glass blanket (24kg/m3) and held in place with 28Gx12mm GI wire
netting. The frame to be fixed to floor/ceiling with
channels with 6mm dia steel screws with
expansion fasteners, 300mm c/c in two rows
(staggered) as per drawing. The lower layer of
Gypsum board to have joints over frame and to be
screwed to the frame at spacing not exceeding
300mm c/c and second layer of Gypsum board to
have joints staggered with respect to the first layer.
All joints between the boards in both layers to be
taped with paper tape and finished with jointing
compound so as to provide smooth surface and
joints with floor and ceiling to be mastic caulking.
Entire work to be done as per drawing and as
directed by E-I-C.
Sqm 44.00
4.02.12 Providing & Fixing of lacquer glass as per
approval in any color fixed with clear neutral
silicon of make GE windily 20/ slipup or Dow
Corning 995 on a perfectly leveled Marine ply of
minimum 12mm thickness mounted on the RCC
wall/any other structure. The Lacquered glass shall
be highly durable, humid resistance, polyurethane
lacquer glass. The glass to be manufactured by
industrial curtain coating process. It should meet
quality standards as per BS EN 1036 1999 &
conform to persoz hardness test of at least 220
oscillations. The substrate of the glass should
confirm to Standard BS EN 572 1995 parts 1 & 2.
Lacquered glass to be manufactured to tight
specifications, relating to consistency of color,
opacity and homogeneity throughout production
campaigns and also to the ageing properties,
mechanical resistance, and resistance to humidity
and to chemical agents of the lacquer. The color of
the lacquer should remain stable when exposed to
normal levels of ultra-violet light in interior
applications.
7/24/2019 Vol II (ICAR Audi Interior 2013)
24/50
S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu
(Rs.)
in figures in words
RATE (in Rs.)
4.02.12.1 Lacquer glass of 6 mm thickness fixed with 25
mm studs fixed on wooden/MS Base frame duly
primer coated, covered with 1 layer of 6 mm thick
Marine ply followed by another layer of 6 mm
thick Superior grade MDF of approved make on
one side. The sides of frame which touches the
masonry will be painted with black Japan.Necessary groove of 6 mm * 6 mm required at
joints to be provided, as per approved details etc
all complete. (base frame to paid in respective
item)
Sqm. 25.00
4.02.13 Providing and Fixing 100 mm. high skirting of
superior quality MDF board cold pressed with 3.5
mm thick veneer of approved quality & as per
required design to be fixed on wall & floor
junction including a 1st class wenge wood lipping
on the top edge. The skirting shall be fastened to
the wall leaving pre-determined spacing from the
floor for fixing of carpet flooring as applicable.
The skirting shall be true to line and plumb andshall be duly spirit polished and finished with
melamine matt coating.
Rmt 950.00
4.03 GRC panel
4.03.1 Providing & fixing Dry Cladding with GRC panel
of 60mm thickness on internal walls upto a height
of 10 mtrs., fixed to internal wall on structural
steel frame work with the help of SS clamps, pins
etc and sealing the joints with approved weather
sealant as per the architectural drawing &
approval. Including necessary scaffoldings
required for installation. Installation to be done by
specialized vendor in strict supervision if rerquired
as per the manufacture's specification. (Thestructural frame work, SS cramps & pins etc shall
be paid separately in respective items)
Sqm. 34.00
4.04 Distempering with 1st quality acrylic distemper,
having VOC (Volatile Organic Compound)
content less than 50 grams/ litre, of approved
brand and manufacture, including applying
additional coats wherever required, to achieve
even shade and color. Including providing and
applying white cement based putty of average
thickness 1 mm, of approved brand and
manufacturer, over the plastered wall surface to
prepare the surface even and smooth complete.
4.04.1 Two Coats Sqm. 2,648.00
7/24/2019 Vol II (ICAR Audi Interior 2013)
25/50
S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu
(Rs.)
in figures in words
RATE (in Rs.)
4.05 Wall painting with premium acrylic emulsion
paint of interior grade, having VOC (Volatile
Organic Compound) content less than 50 grams/
litre of approved brand and manufacture, including
applying additional coats wherever required to
achieve even shade and color. Including providing
and applying white cement based putty of averagethickness 1 mm, of approved brand and
manufacturer, over the plastered wall surface to
prepare the surface even and smooth complete.
4.05.1 Two Coats Sqm. 1,954.00
Low VOC Texture Paint Type-A, B & C:
4.06 Providing and applying Texture Paint with a finish
as per approved sample on interior/External wall at
all levels i/c coat of sealer and two coats of primer
on POP/ prepared leveled surface as per
manufacturer's specification by a specialist
contractor authorized by the manufacturers,
including scaffolding, protection of adjoiningsurfaces, cleaning etc. complete.
4.06.1 Stucco(Texture Paint Type-A):Finish of vapor
permeable having a marble effect in three or more
coats, finished with a steel trowel and protecting
coats of cera wax.
Sqm. 2,269.00
4.06.2 Marmarino Finitura(Texture Paint Type-B):
Finish of vapour permeable lime plaster finish for
exterior/interior with selected marble granules in 3
coats over a coat of primer and final coat of
finitura polished with steel trowel and a protection
coat of cera protectiva as per company
s ecifications.
Sqm. 1,572.00
4.06.3 White Texture paint(Texture Paint Type-C):
Finish of vapor permeable having a marble effect
in three or more coats, finished with a steel trowel
and rotectin coats of cera wax.
Sqm. 307.00
4.07 Wooden Box Paneling
Veneer Box Paneling with marine ply
4.07.1 Providing and fixing Veneer finished wooden Box
paneling over existing Columns consisting of 19
mm thick Marine ply, cold pressed with 3.5 mm
thick veneer of approved make & shade in design
and pattern as per drawings. The panels shall have
grooves of 9.5 mm x 9.5 mm at corners with 6mm
thk wooden lipping around the grooves/or SS
metallic laminate (1.5 mm thick). The panels andthe groove shall be spirit polished and finished
with melamine matt coating to an even shade as
per the approval. Basic Rate of Veneer:Rs-100 per
sft FOR site & of SS metallic laminate: Rs-140 per
sft FOR site.
Sqm. 285.00
Veneer Box Paneling with flexi ply & MS frame
work
7/24/2019 Vol II (ICAR Audi Interior 2013)
26/50
S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu
(Rs.)
in figures in words
RATE (in Rs.)
4.07.2 Providing and fixing Veneer finished wooden Box
paneling over existing Columns consisting of 12
mm thick flexi ply, cold pressed with 3.5 mm
thick veneer of approved make & shade in design
and pattern as per drawings. The panels shall be
installed over a tubular MS base frame of 25 mm *
25 mm as per requirement & have grooves of 9.5mm x 9.5 mm at corners with 6mm thk wooden
lipping around the grooves/or SS metallic laminate
(1.5 mm thick). The panels and the groove shall be
spirit polished and finished with melamine matt
coating to an even shade as per the approval. Basic
Rate of Veneer:Rs-100 per sft FOR site & of SS
metallic laminate: Rs-140 per sft FOR site.
Sqm. 285.00
Laminated Box Paneling
4.07.3 Providing and fixing Laminate finished wooden
Box paneling over existing Columns consisting of
12 mm thick Flexi Ply cold pressed with 1.5 mm
thick Laminate of Approved make & shade indesign and pattern as per drawings. The panels
shall have grooves of 7.5 mm x 7.5 mm at corners
with 6mm thk wooden lipping around the
grooves/or SS laminate as per drawing. The panels
and the groove shall be spirit polished and finished
with melamine matt coating to an even shade as
per the approval of the E-I-C. Basic rate of
laminate: Rs: 70 per sft FOR site
Sqm. 142.00
Wall Paper
4.08 Providing & Installing of wall paper as per
approved samples having 20% recycled content by
weight minimum 10% post-consumer, and meets
or exceeds all type-II requirements of CCC-W-408A/D and industry voluntary standard CFFA-w-
101A/D. Weight of minimum 20 to 13.3 oz/ly
(619 to 452gms/sqm) & having a minimum width
of 52 to 54". Backing of Osnaburg or approved
equivalent, Fire safety norms as per Class A
(ASTM E-84) Tunnel Test, Corner burn test as per
NFPA 286 & Life safety code NFPA 101. All
material & adhesive shall be free from Lead,
Mercury, Cadmium & chromium & have anti
microbial features. (Note: No extras will be paid
for overlapping & wastages or any additional
material required for installation) (Basic cost of
Wall Paper Upto: Rs.100 per sft FOR site)
Sqm. 119.00
Pin-Up Board
4.09 Providing and fixing PIN-UP BOARD of size as
per drawing using 12mm thick cellotex board with
backing of 6mm BWP ply of approved brand with
hidden second class teakwood margin on all edges
and with handloom fabric stretched and pasted on
top of the board (the basic cost of the fabric shall
be Rs. 1200 per metre). Frame and the backing ply
shall be fixed to the wall with approved fixing
arrangement, all incidentals complete as per
drawings / as directed.
Sqm. 50.00
7/24/2019 Vol II (ICAR Audi Interior 2013)
27/50
S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu
(Rs.)
in figures in words
RATE (in Rs.)
Magnetic White board
4.10 Providing and fixing of magnetic white board of
approved make scratch resistant matt finish P3
surface consisting of ceramic steel of thickness
0.55mm to 0.65 mm, having a weight of 3-4 kgs
per sqm. The core material shall be of interior
grade 9mm thickness with density 700 to 800
k /cum.With a backing of galvanized steel of 0.25 mm
thickness having approximate weight of 1.96
kgs/sqm. This entire assembly shall be housed in
an anodized aluminum extruded section
conforming to IS-6477 and IS-3965/2673 and
corners of moulded ABS. The front and back
surface will be affixed with 10-15 micron silver
matt satin finish. This should be provided with
clamp for hanging arrangement with locking
facility including one set of accessories comprising
of magnets, magnetic dry markers and magnetic
4.10.1 4 x 10 (1200mm x 3000mm) Nos 7.00
4.10.2 4 x 6 (1200mm x 1800mm) Nos 11.00
4.10.3 3' x 4' (900mm x 1200mm) Nos 9.00
4.10.4 2' x 4' (600mm x1200mm) Nos 7.00
4.11 Structural Steel Frame work
4.11.1 Providing and fixing structural steel frame (for dry
cladding with 30 mm thick gang saw cut with
machine cut edges sand stone) on walls at all
heights using M.S. square/ rectangular tube in the
required pattern as per architectural drawing,
including cost of cutting, bending, welding etc.
The frame work shall be fixed to the wall with the
help of M.S. brackets/ lugs of angle iron/ flats etc.which shall be welded to the frame and embedded
in brick wall with cement concrete block 1:2:4 (1
cement :2 coarse sand :4 graded stone aggregate
20 mm nominal size) of size 300x230x300 mm,
including cost of necessary centering and
shuttering and with approved expansion hold
fasteners on CC/RCC surface, including drilling
necessary holes.
Kg 344.00
Approved cramps/ pins etc. shall be welded to the
frame work to support stone cladding, the steel
work will be given a priming coat of Zinc primer
as approved by Engineer in- charge and painted
with two or more coats of epoxy paint (Shopdrawings shall be submitted by the contractor for
approval before execution). The frame work shall
be fixed in true horizontal & vertical lines/planes.
(Only structural steel frame work shall be
measured for the purpose of payment, stainless
steel cramps shall be paid for separately and
nothing extra shall be paid).
7/24/2019 Vol II (ICAR Audi Interior 2013)
28/50
S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu
(Rs.)
in figures in words
RATE (in Rs.)
4.11.2 Providing and fixing adjustable stainless steel
cramps of approved quality, required shape and
size, adjustable with stainless steel nuts, bolts and
washer (total weight not less than 260 gms), for
dry stone cladding fixed on frame work at suitable
location, including making necessary recesses in
stone slab, drilling required holes etc complete asper direction of the Engineer-in-charge.
Each 35.00
Mosaic/Porcelain wall tiles
4.12 Providing and laying Joint free Mosaic/Porcelain
especially designed and manufactured wall tiles
300 x 600mm or as specified by the engineer in
charge of thickness not less than 9mm of 1st
quality of approved make in all colors, shades as
approved laid on 20mm thick cement mortar 1:4
(1 cement:4 coarse sand) including jointed with
Laticrete or approved equivalent jointing
compound of matching shade etc. complete as per
direction of E-I-C.
Sqm 365.00
Gypsum Board Partition (Perforated & Non
perforated Gypsum Board)
4.13 Providing and fixing partition Upto ceiling height
consisting of G.I. frame and required board,
including providing and fixing of frame work
made of special section power pressed/ roll form
G.I. sheet with zinc coating of 120 gms/sqm(both
side inclusive), consisting of floor and ceiling
channel 50mm wide having equal flanges of 32
mm and 0.50 mm thick, fixed to the floor and
ceiling at the spacing of 610 mm centre to centre
with dash fastener of 12.5 mm dia meter 50 mm
length or suitable anchor fastener or metal screws
with nylon plugs and the studs 48 mm wide havingone flange of 34 mm and other flange 36 mm and
0.50 mm thick fixed vertically within flanges of
floor and ceiling channel and placed at a spacing
of 610 mm centre to centre by 6 mm dia bolts and
nuts, including fixing of studs along both ends of
partition fixed flush to wall with suitable anchor
fastener or metal screws with nylon plugs at
spacing of 450 mm centre to centre, and fixing of
boards to both side of frame work by 25 mm long
dry wall screws on studs, floor and ceiling
channels at the spacing of 300 mm centre to
The boards are to be fixed to the frame work with
joints staggered to avoid through cracks, M.S.
fixing channel of 99 mm width (0.9 mm thick
having two flanges of 9.5 mm each) to be providedat the horizontal joints of two boards, fixed to the
studs using metal to metal flat head screws,
including jointing and finishing to a flush finish
with recommended jointing compound, jointing
tape, angle beads at corners (25 mm x 25 mm x
0.5 mm), joint finisher and two coats of primer
suitable for board as per manufacture's
specification and direction of engineer in charge
4.13.1 75 mm overall thickness partition with 12.5 mm
thick double skin fire rated board conforming to
IS: 2095: art I
Sqm 30.00
7/24/2019 Vol II (ICAR Audi Interior 2013)
29/50
S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu
(Rs.)
in figures in words
RATE (in Rs.)
4.13.2 Providing & fixing single layer 12.5 mm thick
perforated gypsum board wall paneling using
board of size 1200*2400 mm, with four tapered
edges, Upto 16% perforation area of board with 12
mm dia holes (square), backed with acoustic tissue
having NRC 0.6 to 0.75, screw fixed with drywall
screws of 25 mm at 300 mm centers. screwed to45 mm channel section 0.4 mm thick having two
flanges of 18 mm each placed at 600 mm C/C in
25*25 mm wall angle 0.4 mm thick having two
flanges of 25 mm each, fixed to floor & ceiling
with nylon sleeves & steel screws at 610 mm
centers. Fixing bracket 0.9 mm thick, 29.5 mm
wide & 195 mm long, fixed to the wall with the
help of nylon sleeves & steel screws at 900 mm
C/C to hold the sections in position & level.
Sqm 508.00
Square edges of the board to be finished with
jointing compound, joint paper tape & two coats
drywall top coats per recommended practice of the
manufacturer, including providing & fixing of 50
mm thick resin bounded 24 kg/cum glass woolinsulation fixed to the frame with the help of GI
wire mesh to improve the NRC etc all complete.
Zigzag Contours Plaster
4.14 Providing zigzag contours in cement plaster on the
existing wall in cement mortar (1:4) 38mm thick
average (12mm thick to 62mm thick) as shown in
drawings held in with 28GX12mm GI wire netting
fixed with nails. The entire plastered surface shall
be finished with two coats of acrylic emulsion
black paint over a coat of primer. Entire work to
be done as per drawing and specifications.
Sqm 212.00
Acoustic Plaster Paint
4.15 Providing & applying K-13 Standard Grade, sound
absorbing cellulose-base plaster, organic in nature,
free of asbestos, fiberglass, or manmade mineral
fibers and treated with fire resistant chemicals,
sprayed with high pressure equipment to the
substrate in white color, construction material
Class B1 according to DIN 4102, to be sprayed at
an average thickness of 50mm, including
protection cover for surfaces that are not to be
sprayed. Clips, hangers, supports, sleeves and
other attachments to substrate shall be fixed by
other agencies prior to spray plaster activity
whereas ducts, piping and other suspended
equipment shall be placed / fixed after the spray
activity. All materials shall be supplied in
unopened containers bearing the name of
manufacturer, product identification and reference
to UL testing.
Sqm 25.00
7/24/2019 Vol II (ICAR Audi Interior 2013)
30/50
S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu
(Rs.)
in figures in words
RATE (in Rs.)
The manufacturer or the applicator shall provide
MTC complying material with ASTM E-84 / U. L.
723, tested at a minimum of 5 thk Class I, Class
A, Flame Spread: 5, Smoke Development: 5,
ASTM E-1042, Non corrosive per UMB-80, Bond
Deflection per ASTM E-759: 6 deflection in 10
span no spalling or delamination. The plastershall be cured with natural ventilation. The
applicator / manufacturer shall provide with test
data that the acoustical plaster gives absorption co-
efficient NRC 0.95 and meet the individual
absorption coefficient at 125hz=0.26, at
250hz=0.68, at 500hz=1.05, at 1khz=1.10, at
2khz=1.03 at complete octave band.
5.00 DOORS, WINDOWS, GLAZING AND
COVERING
5.01 Glass Partition on "C" channel.
5.01.1 Providing & Fixing 12 mm thk. Toughened Clear
Glass partition on aluminum 'C' channel of
25x25x1mm size with Silicon Sealant filling as
approved, inclduing making groove of 25 mm x 25
mm in floor with floor cutting machine, fixing
aluminium "C" channel in the groove with suitable
screws and fasteners and work to be completed as
er the drawin s
sqm 298.00
5.01.2 Providing & Fixing 8 mm thk. Toughened Clear
Glass in windows on aluminum 'C' channel of
25x25x1mm size with Silicon Sealant filling as
approved. The work is to be completed by fixing
the cannel to the required location and then
lacin the lass.
sqm 11.00
5.02 Frameless Glazed Door
5.02.1 Providing and fixing 12 mm thick frameless
toughened glass door shutter of approved brand
and manufacture, including providing and fixing
top & bottom pivot & spring type fixing
arrangement and making necessary holes etc. for
fixing required door fittings, all complete as per
direction of Engineer-in-charge (Door handle, lock
and stopper etc. to be paid separately).
sqm 57.00
5.03 Film on Glass:
5.03.1 Providing and fixing antishatter sun film
(Minimum thickness of 2 mil) on glass for
Etching effectas per detail design and pattern.
sqm 183.00
5.03.2 Providing and fixing frosting film (Minimum
thickness of 2 mil) in required pattern as per the
approval, design & Pattern.
sqm 178.00
5.04 Glass Door Fittings & Accessories
Supply and Fixing of following door fittings as per
selection of the Engineer-in-charge
5.04.1 SS Door stopper/ buffer floor stop half dome with
45mm dia with fixing accessories, in satin Chrome
finish.
Nos 26.00
7/24/2019 Vol II (ICAR Audi Interior 2013)
31/50
S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu
(Rs.)
in figures in words
RATE (in Rs.)
5.04.2 Top pivot point: top patch with plastic socket for
top pivot 15 mm , Satin Stainless Steel finish.
Nos 26.00
5.04.3 Over Panel Side Panel Connecting Patch with
Pivot, with inserts (1 x stop, 2 x blank), Satin
Stainless Steel finish
Nos 39.00
5.04.4 Top & Bottom patch fitting: top patch 15 mm ,
Satin Stainless Steel finish & bottom patch with
insert for floor spring spindle, or round pivot 14
mm . Satin Stainless Steel Finish.
Nos 39.00
5.04.5 SS glass door pull handle: back to back with
350mm CTC, adjustable fixing for glass, wood
and metal doors in satin stainless steel. The pull
handles should have supporting washer with raised
bevelling on the outer surface. Length =450mm,
25mm dia - SS304
Nos 26.00
5.04.6 Heavy duty floor spring with 90 Hold Open: floor
spring BTS 75V EN 1-4 with std. spindle andcover plate. The floor spring with backcheck and
adjustable closing speed from 175. With 90 hold
open. As per EN 1154. Satin stainless steel Finish.
Nos 26.00
5.04.7 Patch lock for glazed doors: corner lock, prepared
for Europrofile cylinder, single throw, bolt
projection 20 mm including epc both side key
operation and lock keeper plate, Satin Stainless
Steel Finish.
Nos 39.00
5.04.8 Wall to Glass Clamping Patch: Std with pivot
insert 15 mm with fixing plate, Satin Stainless
Steel Finish.
Nos 26.00
5.04.9 Glass to Glass Connecting Patch to Wall/Ceiling:
Universal patch fitting for connection of overpanel
and sidelight, Std for 12 mm glass, with or with
out fin on one side, with inserts (1 x stop, 2 x
blank), Satin Stainless Steel Finish.
Nos 26.00
5.04.10 Double Glass Connector: Universal patch fitting
for connection of overpanel and sidelight, Std for
12 mm glass, with or with out fin on one side, with
inserts (1 x stop, 2 x blank), Satin Stainless Steel
Finish.
Nos 26.00
5.05 Providing and fixing ISI marked flush door
shutters conforming to IS : 2202 (Part I) decorative
type, core of block board construction with frame
of 1st class hard wood and well matched teak 3 ply
veneering with vertical grains or cross bands and
face veneers on both faces of shutters.
5.05.1 35 mm thick including ISI marked Stainless Steel
butt hinges with necessary screws
sqm 92.00
7/24/2019 Vol II (ICAR Audi Interior 2013)
32/50
S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu
(Rs.)
in figures in words
RATE (in Rs.)
5.06 Providing and Fixing Cherry/Maple beech wood
SR (sound resistant) doors made out of
Marandiwood frame of size 50 x 50 mm at 450
mm c/c covered with 12 mm thick (in two layers
of 6 mm each) Superior Quality MDF on both
sides cold pressed panels made with 3.5 mm thick
veneer (or as approved by the E-I-C) finish as perrequired design. The door shall be framed with
Cherry/Maple beach wood of section thickness 72
x 150 mm all around as per design. The gap of 50
mm within the door shall be filled up with 50 mm
thick Fiber Glass wool packed in hessian cloth for
sound insulation. All natural wood & veneer
surfaces shall be spirit polished and finished with
a coat of melamine matt finish.
Sqm. 155.00
The door shall have all stainless steel fittings
including butt hinges (4 nos each panel) of
approved make stainless steel AISI 316 grade butt
hinges of size 100x75x2.5 mm with self
lubricating ball bearing complete with screw and
satin finish stainless steel AISI 304 grade leverhandle , Cylinder , Closed Body Mortise lock with
Strike Plate, Heavy Door Closer of approved make
complete with latch lock, strike plate and screws
etc. and as per direction of E-I-C.
5.07 Providing wood work in frames of doors,
windows, clerestory windows and other frames,
wrought framed and fixed in position with hold
fast lugs or with dash fasteners of required dia &
length ( hold fast lugs or dash fastener shall be
aid for se aratel .5.07.1 Second class teak wood cum 4.00
Roller Blinds
5.08 Providing and Fixing Roller blinds of shade and
type as given below and of approved make
comprising of roller tube, clutch, idler, installation
brackets and bottom weight. Roller tube shall be of
anodized extruded Aluminum section of min.
1.0mm thickness and 32mm O.D. Clutch shall be
of wrap spring design with high strength fiberglass
reinforced polyester assembly. Clutch mechanism
shall be crash proof, prevent slippage and shall
raise and lower smoothly to any desired height.
Clutch shall never need adjustment.
5.08.1 With Screen fabric Sqm. 207.00
5.08.2 With Solar Blinds Sqm. 240.00
5.09 DOOR FRAME & SHUTTER: Providing &
Fixing of CBRI tested & TAC approved 77mm
thick Acoustic cum Fire/Smoke check door of 120
minutes fire rating with 38dB Noise reduction
property as per the specification mentioned below:
7/24/2019 Vol II (ICAR Audi Interior 2013)
33/50
S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu
(Rs.)
in figures in words
RATE (in Rs.)
5.09.1 Supply & Installation of Cherry/Maple Wood Door
Frame of section 100mm x 75mm with heat
activated intumescent fire seal strip of size 10mm
x 4mm Twin Type (Astroflame U.K make or
approved equivalent) mounted on the door frames
on all three sides and one coat of anti-termite fire
retardant primer. Door shutter consisting of 77mmthick door shutter having 38 dB acoustic cum 120
min. fire rating having infill of 49mm thick resin
bonded glasswool of 24kg / M3 density with FR
Acrylic Sealant sandwiched between two 9mm
thick (Starpan Make or Approved equivalent)
Calcium Silicate boards a 100% without asbestos,
Brucite and Meerschaum having a density not less
than 1150kg/M3 and thermal conductivity 0.14
W/m* K faced with 3.4mm thick commercial ply
1mm laminated on both sides with heat activated
intumescent fire seal strip of size 10mm x 4mm
mounted in the grooves having hardwood lipping.
Sqm 114.00
Including Marshall Acoustic seals around the jamb
and head on frame rebates, which is adjustable to
seal for noise, light and smoke for a maximum gap
of 8mm between frame and shutter.
Consisting of Drop Seal (2 nos): A medium
temperature smoke door bottom seal, with an
extruded siliconsealing component. It is heavy
duty automatic door bottom seal which is spring
leaded to lift clear of the floor as soon as the door
leaf is opened by a few millimeters. The seal is
operated automatically by pressure against the
door jamb on the adjusting screw. It seals when
the door closes and retracts automatically when the
door is opened. It is self-leveling.
Astragal Seal (1 NO): Marshall Astragal seal is
acoustic and smoke astragal design for meeting the
stiles of rebated double leaf doors. The aluminium
trim conceals the sealing portion of the seal in
rebate to provide acoustic properties.
5.09.2 Door Closer:Supply & Installation of heavy duty
door closer, CE & EN 1154 certified 2 hrs fire
rated with 10 years warranty tested to BS 476 Part
22 and as er a roved make.
Nos 48.00
5.09.3 Panic Exit Devices: Supply & Installation of
single/double leaf panic exit devices, CE & EN
1125 certified 2 hrs fire rated tested in accordance
with BS 476 Part 22.5.09.3.1 Single Leaf Panic Bar Nos 4.00
5.09.3.2 Double Leaf Panic Bar Nos 24.00
5.09.3.3 Out Side Access Trim: Supply & Installation of
Out Side Access Trim
Nos 48.00
5.09.4 Dead Lock: Supply & Installation of dead lock
with cylinder, 2 hrs fire rated having 7 years
mechanical warranty tested to BS 476 Part 22 and
as tested from CBRI Roorkee.
Nos 48.00
7/24/2019 Vol II (ICAR Audi Interior 2013)
34/50
S.N. DESCRIPTION OF ITEM UNIT QTY AMOUNT in figu
(Rs.)
in figures in words
RATE (in Rs.)
5.09.5 D-Type Handle:Supply & Installation of stainless
steel D- Type pull handle of size 200mm long
19mm dia.
Pair 48.00
5.09.6 Hinges: Supply & Installation of 304 grade
stainless steel ball bearing hinges of size 100mm x
100mm x 3mm.
Nos 240.00
5.10 Providing and cold pressing approved quality &
shade Veneer (3.5mm thick) on the Panels of
existing doors including cutting, pasting &
finishing the doors panels with lacquered polish.
The panels shall be fixed leaving a precise gap of
10 mm between two panels. (Basic Rate of
Veneer=RS.100/- per sft FOR site)
Sqm 206.00
5.11 Providing & fixing 18mm thick mirror polished,
machine cut black granite (galaxy type)
door/window frame of required width with rebate
of required size as per approved sample and
making full round moulding on exposed edgesincluding rubbing, curing etc. complete at all
levels and as er direction of E-I-C.5.11.1 Door / Window frame 300mm width (with
necessary groove or overlap required for the
installation of lass or door anel
Rmt 295.00
5.11.2 Moulding of size Upto 40x40mm Rmt 591.00
5.12 Windows & Shutters
5.12.1 Sliding Glazed Aluminum Window SGW1
(Control Room)
Sqm 20.00
Providing