91
TENDER NO: WAP/ INFRA./MIH/KALINGA-BBS/ODISHA TENDER DOCUMENT FOR CONSTRUCTION OF MULTIPURPOSE INDOOR HALL AT KALINGA SPORTS COMPLEX, BHUBANESWAR, ODISHA TENDER NO: WAP/ INFRA./MIH/KALINGA-BBS/ODISHA VOLUME 4: PRICE SCHEDULE Issued to M/s_______________________________________ _______________________________________ Tele-fax: +91-124-2397391, Email: [email protected], Website: www.wapcos.co.in Preamble to the Price Schedule

tender document - WAPCOS Limited

Embed Size (px)

Citation preview

TENDER NO: WAP/ INFRA./MIH/KALINGA-BBS/ODISHA

TENDER DOCUMENT

FOR

CONSTRUCTION OF MULTIPURPOSE INDOOR HALL AT KALINGASPORTS COMPLEX, BHUBANESWAR, ODISHA

TENDER NO: WAP/ INFRA./MIH/KALINGA-BBS/ODISHA

VOLUME 4: PRICE SCHEDULE

Issued to M/s_______________________________________

_______________________________________

Tele-fax: +91-124-2397391, Email: [email protected],

Website: www.wapcos.co.in

Preamble to the Price Schedule

TENDER NO: WAP/ INFRA./MIH/KALINGA-BBS/ODISHA

1. GENERAL

The nature of this contract is measured Item Rate Contract and the Bill of Quantities (BOQ) shallreflect this fact. BOQ shall be read and construed in conjunction with other Bid Documents.

General directions and description of work and material given in the Technical Specification are notnecessarily repeated in the Bill of Quantities. The Technical Specification forms an integral part ofthe Bill of Quantities.

The Tenderer is obliged to check the number of the pages of the Bill of Quantities and should any befound missing or duplicated or the figures or writing indistinct, the Tenderer must notify theEmployer/Engineer at once and have the matter rectified before the Tender is submitted.

No liability whatsoever will be accepted in respect of any claim for errors in the Tenderer’s offerresulting from failure to comply with the afore-going.

The Tenderer is deemed to have visited the site and fully acquainted himself as to the location andits surroundings and taken into account all relevant factors pertaining to the site and all theconditions which may affect the performance of the works.

The Tenderer is also deemed to have surveyed the actual condition of the site and made his ownassessment of the type and extent of the works prior to submitting his offer.

2. QUANTITIES

Notwithstanding that practical care was exercised in preparing the BOQ, but all quantities givenherein shall be deemed to be estimated quantities of the work to be done but they are not to betaken as actual and correct quantities of the work to be executed and they are not to absolve thecontractor of his obligations under the Contract. They are not to be taken as guarantee that theactual quantities increase or decrease, and any claim whatsoever submitted for cost or extraexpenses incurred from such increase or decrease will not be accepted by Engineer-in-charge exceptwhere else stipulated in the Contract.

3. MATERIALS

All materials used are to be of the best new available and subject to the Employer/Engineerapproval, and of durable nature, guaranteed, not liable to any base exchange and manufacturedaccording to applicable IS Standards. Execution also is subject to approval of Employer/Engineer andshall be the best available common practice in engineering codes at the time of execution.

Items that contain materials or products of special make with names of manufacturers are to betaken as samples of what will be required. Subject to the Employer/Engineer approval, theContractor may, at his discretion, offer similar products of other make if the equivalent quality of thespecified materials is guaranteed. In this case, the Contractor shall submit a description and/ordrawings showing all technical conditions, characteristics, make, type and address of Manufacturer… etc., of the materials offered as alternatives.

4. PRICES AND CURRENCY

The rates & prices given hereunder in the BOQ shall be in Indian Rupees. The rates quoted for thecontract shall be exclusive of all taxes. Furthermore inflation and escalation or changes whatsoevershall not be subject of claim later on. The Unit Prices entered against the various items in the

TENDER NO: WAP/ INFRA./MIH/KALINGA-BBS/ODISHA

following Bill of Quantities includes all operations for execution, completion and maintenance of thevarious items of the works finished completely in every respect till the final acceptance as specifiedor described in the Tender Documents, with or without modifications, either by way of additions ordeductions, or alterations as may be offered in writing during the progress of the works, and include,without being limited to, all matters and things particularly referred to in the Tender Documents.

The Unit Price shall cover all costs of every kind whatsoever including, without being limited to, allcharges for additional site installations, relocation, supervision, labor, transportation and supply ofmaterials; the provision, maintenance, use and efficient repair of all plant, equipment and applianceof every kind, the construction and maintenance of all temporary works, the performance of allservices and the fulfillment of all obligations and responsibilities herein defined.

The Tenderer shall be deemed to have fully considered all the conditions, obligations, andrequirements of the Tender Documents before entering the respective unit price against the variousitems of the Bill of Quantities.

The works, materials or activities listed in the following shall always be considered as auxiliary worksto be included in the Unit Prices bid for any item in the Bill of Quantities:

Any measurement for execution and payment of the works, including the provision ofmeasuring instruments, gauges, setting out marks, marking paint and relevant tools, labor,etc., the maintenance and preservation of gauges and setting-out marks during theexecution of the works.

Provision of small tackle tools or any other equipment required for the execution of theworks

Supply of consumable for the Contractor’s equipment. Removal of all contamination (refuse, debris, building rubbish and the like) arising from or in

connection with the Contractor’s work. Protection of the executed works and of the items made available for execution of the works

from damage, fire, inclement weather, vandalism and theft etc., to the time of final acceptance. Transportation of all materials and structural components from the storage places on site to

the points of use and return transportation, if required. Submitting and transporting any samples required. Carrying out tests on materials and works, etc., that is required by the Engineer-in-charge. Fuel and lubricants for operation of Contractor’s equipment. All safety precautions and measures for safeguarding labor as well as securing surrounding

areas. Lighting of the work site.

5. RIGHTS OF EMPLOYER

The following rights are reserved to the Employer: To omit individual items mentioned in the Schedule of Prices if not required in the opinion of

the Employer and/or to replace them should it be more advantageous to execute them inanother way.

To order execution of alternative or provisional items as if they were main items. To order execution of additional works as well as alternatives of works, always in conformity

with the conditions outlined in the Contract.

Any order and/or delivery of material or equipment by the Contractor for performance of the worksmay only be based on instructions and/or approved execution drawings by the Engineer-in-charge.

TENDER NO: WAP/ INFRA./MIH/KALINGA-BBS/ODISHA

All equipment and materials for installation and finishing works to be incorporated in this contractshall prior to ordering and/or delivery by the Contractor, be approved by the

Employer/Engineer-in-charge both in respect of quality and type as well as of quantity.

6. SITE ACCESS AND STORAGE

The Tenderer shall visit the site and ascertain the location of required access onto the site and thelocation of allowance for complying with the requirements and for the reinstatement to originalcondition of all roads and areas used or disturbed by the Contractor to the satisfaction of theEngineer-in-charge.

7. SITE INSTALLATION

All costs of labor, works, provisions, materials and equipment for Site Installations required by theContractor and stipulated in the Tender Documents shall be included in the various unit prices of theBill of Quantities. No extra payment will be allowed by the Employer for any of these activities.

8. OUTLINES1. The Bill of Quantities shall contain items for the Works to be carried out by the contractor.2. The contractor shall be paid for the quantum of work done at the rate quoted for each item

in the Bill of Quantities.3. The rate or price rounded off to the nearest Indian Rupee shall be entered against each item

in the Bill of Quantities both in figures and words. The cost of items against which theContractor has failed to enter a rate or price shall be deemed to be zero.

4. Where there is a discrepancy between the rates in words and figures, the lesser of the twowill only be taken in to consideration.

5. Where there is a discrepancy between the unit rate and line item total resulting frommultiplying the unit rate by the quantity, the unit rate as quoted will govern.

6. Where there is an arithmetical discrepancy in the page total as well as grand total, thecorrected total by the Employer will govern.

7. The rates quoted in the BOQ shall be for carrying out the work in conformity to the ISStandards and Technical Specifications and other Terms and Conditions set out in the BidDocument

8. All pages in the BOQ should be signed without omission. All corrections/over writing shouldbe properly attested by the Bidder.

9. Change in the Quantities - If the final quantity of the work done differs from the quantity inthe Bill of Quantities for the particular item/items, the rates as in the agreement for therelevant items shall be paid.

10. The rate quoted in the BOQ shall be exclusive of all eligible taxes.11. The Method of measurement of completed work for payment shall be in accordance with

the requirement as stated in the individual section of Technical Specifications.

S. No. Description AMOUNT

1 EARTH WORK

2 CONCRETE WORK

3 REINFORCED CEMENT CONCRETE

4 MASONARY WORK

5 CLADDING WORK

6 WOOD WORK & PVC WORK

7 STEEL WORK

8 FLOORING

9 ROOFING

10 FINISHING

11 DISMANTLING AND DEMOLISHING

12 ROAD WORK

13 ALUMINIUM WORK

14 WATER PROOFING

15 HORTICULTURE & LANDSCAPING

Total (Civil Work)

16 Non DSR Amount

Electrical Work

Plumbing and Fire Fighting Works

HVAC Works

Grand Total

PROJECT - CONSTRUCTION OF MULTIPURPOSE INDOOR HALL ATKALINGA SPORTS COMPLEX, BHUBANESWAR, ODISHA

SUMMARY OF WORK

WAPCOS Ltd.Signature of Bidder

S. NO. REF.NO. DESCRIPTION UNIT RATE QTY. AMOUNT

1.0 2 EARTH WORK

1.01 EW-23 Filling in foundation and plinth with excavated materials includingwatering and ramming as directed by the Engineer-in-charge for 100cum

100 Cum 56.00

1.02 EW-15 Filling in foundatin and plinth with sand watered and rammed includingcost of sand & labour

Cum 55.00

1.03 DSR-2.6 Earth work in excavation by mechanical means (Hydraulicexcavator)/manual means over areas (exceeding 30 cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out anddisposal of excavated earth lead upto 50 m and lift upto 1.5 m, asdirected by Engineer-in-charge.

2.6.1 All kinds of soil Cum 2991.00

1.04 DSR-2.10

Excavating trenches of required width for pipes, cables, etc includingexcavation for sockets, and dressing of sides, ramming of bottoms,depth upto 1.5 m, including getting out the excavated soil, and thenreturning the soil as required, in layers not exceeding 20 cm in depth,including consolidating each deposited layer by ramming, watering,etc. and disposing of surplus excavated soil as directed, within a leadof 50 m :

2.10.1 All Kinds of soil2.10.1.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm

diaMeter 500.00

1.05 DSR-2.26

Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials.

2.26.1 All kinds of soil Cum 200.00

PROJECT - CONSTRUCTION OF MULTIPURPOSE INDOOR HALL AT KALINGA SPORTS COMPLEX, BHUBANESWAR, ODISHABILL OF QUANTITIES (CIVIL)

WAPCOS Ltd.Signature of Bidder

S. NO. REF.NO. DESCRIPTION UNIT RATE QTY. AMOUNT

1.06 DSR-2.11

Extra for excavating trenches for pipes, cables etc. in all kinds of soilfor depth exceeding 1.5 m, but not exceeding 3 m. (Rate is overcorresponding basic item for depth upto 1.5 metre).

Meter 250.00

1.07 DSR-2.34

Supplying chemical emulsion in sealed containers including delivery asspecified.

a) 2.34.1 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% litre 302.00

1.08 DSR-2.35

Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost ofchemical emulsion) :

2.35.3 Treatment of soil under existing floors using chemical emulsion @ onelitre per hole, 300 mm apart including drilling 12 mm diameter holesand plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) tomatch the existing floor:

a) 2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration Sqm 543.00

Total of sub-head (1.0)

2.0 4 CONCRETE WORK2.01 CONC-

4aCement concrete (1:4:8) with 4cm. Size crusher broken hard Granitemetal including cost of all labour, materials with all taxes, lead,T & Petc all complete .

Cum 85.00

2.02 CONC-7a (I)

Cement concrete (1:2:4) with 12mm size crusher broken hard granitemetal including cost of all labour, materials with all taxes, lead, T & Petc all complete.

Cum 5.00

2.03 DSR-4.2 Providing and laying cement concrete in retaining walls, return walls,walls (any thickness) including attached pilasters, columns, piers,abutments, pillars, posts, struts, buttresses, string or lacing courses,parapets, coping, bed blocks, anchor blocks, plain window sills, fillets,sunken floor etc., up to floor five level, excluding the cost of centering,shuttering and finishing :

a) 4.2.3 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mmnominal size).

Cum 5.00

WAPCOS Ltd.Signature of Bidder

S. NO. REF.NO. DESCRIPTION UNIT RATE QTY. AMOUNT

2.04 DSR-4.17

Making plinth protection 50mm thick of cement concrete 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominalsize) over 75mm thick bed of dry brick ballast 40 mm nominal size,well rammed and consolidated and grouted with fine sand, includingnecessary excavation, levelling & dressing & finishing the top smooth.

Sqm 131.00

Total of sub-head (2.0)

3.0 5 REINFORCED CEMENT CONCRETE

3.01

OSR 4(I) R.C.C work in ground floor of M-20 grade with 20mm & down gradecrusher broken hard Granite chips including hoisting & laying with costof all labour, materials with all taxes, lead ,T & P etc all complete .

Cum 182.00

3.02

RCC-5(I)

R.C.C work in ground floor of M-25 grade with 20mm & down gradecrusher broken hard Granite chips including hoisting & laying with costof all labour, materials with all taxes, lead ,T & P etc all complete .

Cum 410.00

(II) For first floor / below G.L. beyond 1.5 upto 4.5m Cum 275.00(III) For second Floor (Add 15% of labour cost on 1st Floor) Cum 90.00(IV) For third floor (Add 15% of labour cost on 2nd Floor) Cum 26.00(V) For G.L. beyond 4.5 m upto 7.5m. (Add 20% on labour cost of basic

item)Cum 5.00

3.03

RCC 6(I) R.C.C work in ground floor of M-30 grade with 20mm & down gradecrusher broken hard Granite chips including hoisting & laying with costof all labour, materials with all taxes, lead ,T & P etc all complete .

Cum 5.00

(II) For first floor / below G.L. beyond 1.5 upto 4.5m Cum 5.00

3.04 OSR 9A(I)

Supplying, fitting and placing uncoated HYSD bar reinforcementcomplete as per drawing and technical specification.

Qntl. 457.00

(II) For first floor Qntl. 260.00(III) For 2nd floor Qntl. 109.00(IV) For 3rd floor Qntl. 41.00

WAPCOS Ltd.Signature of Bidder

S. NO. REF.NO. DESCRIPTION UNIT RATE QTY. AMOUNT

3.05RCC-10 Rigid smooth centring and shuttering for R.C.C. works including false

work and dismantling then after casting including cost of materials allcomplete.

3.06 RCC-A(i) R.C.C. Floor and Roof Slabs, Landings, Balconies, Projecting, SunShades and Chajja up to 4.3m height (Ground Floor).

Sqm 28.00

A(ii) For first floor Sqm 543.00A(iii) For 2nd floor Sqm 297.00

3.07 RCC-B(i) R.C.C. Stairs excluding landing but including railing inGround Floor Sqm 54.00

B(ii) For first floor Sqm 27.00

3.08 RCC-C(i) R.C.C. Foundation, Plinth Band, Footings, Bases of Columns, MassConcrete & Precast Slabs etc. in Ground Floor. Sqm 332.00

3.09 RCC-D(i) R.C.C. Beams, Column, Grider and Bressmer, etc. in Ground Floor Sqm 1204.00

D(ii) For first floor Sqm 508.00D(iii) For 2nd floor Sqm 173.00D(iv) For 3rd floor Sqm

3.10 RCC-E(i) R.C.C. Lintels in Ground Floor Sqm 15.05E(ii) For first floor Sqm 12.04E(iii) For 2nd floor Sqm 3.01

3.11 RCC-Fi) R.C.C. Walls and Fins including attached Pillasters in Ground Floor Sqm 482.00

3.12 RCC-H(i) Centering & Shuttering for Slope Roof upto 3.60m Sqm 40.00

H(ii) For first floor Sqm 40.00H(iii) For 2nd floor Sqm 20.00

3.13 DSR-5.9 Centering and shuttering including strutting, propping etc. and removalof form for all heights:

h) 5.9.15 Small lintels not exceeding 1.5 m clear span, moulding as in cornices,window sills, string courses, bands, copings, bed plates, anchor blocksand the like

Sqm 100.00

i) DSR-5.9.16

Edges of slabs and breaks in floors and walls

5.9.16.1 Under 20 cms wide metre 31.00

3.14 DSR-5.30

Add for plaster drip course/ groove in plastered surface or moulding toR.C.C. projections.

metre 1281.00

WAPCOS Ltd.Signature of Bidder

S. NO. REF.NO. DESCRIPTION UNIT RATE QTY. AMOUNT

3.15 DSR-5.35

Add for using extra cement in the items of design mix over and abovethe specified cement content therein.

Quintal 321.00

3.16 DSR-5.46

Providing and fixing of expansion joint system of approved make andmanufacture for various roof locations as per approved drawings anddirection of Engineer-In-Charge. The joints shall be of extrudedaluminum base members with, self aligning and self centeringarragement support plates as per ASTM B221-02. The system shall besuch that it provides water tight roof to roof /roof to corner joint coverexpansion control system that is capable of accommodatingmultidirectional seismic movement without stress to its components.System shall consist of metal profile that incorporates a universalaluminum base member designed to accommodate various projectconditions and roof treatments. The cover plate shall be designed ofwidth and thickness required to satisfy movement and loadingrequirements and secured to base members by utilizingmanufacturer’s pre-engineered self-centering arrangement that freelyrotates / moves in all directions. The Self centering arrangement shallexhibit circular sphere ends that lock and slide inside thecorresponding aluminum extrusion cavity to allow freedom ofmovement and flexure in all directions including vertical displacement.The Joint System shall resists damage or deterioration from the impactof falling ice, exposure to UV, airborne contaminants and occasionalfoot traffic from maintenance personnel. Provision of Moisture BarrierMembrane in the Joint System to have water tight joint is mandatoryrequirement. (Material shall confirm to ASTM 6063.)

(i) 5.46.1 Roof Joint of 100 mm gap Meter 25.00

3.17 DSR-5.25

Providing and fixing in position copper plate as per design forexpansion joints.

Kg 100.00

3.18 DSR-5.26

Providing and filling in position, blown bitumen in expansion joints. Cum 0.10

WAPCOS Ltd.Signature of Bidder

S. NO. REF.NO. DESCRIPTION UNIT RATE QTY. AMOUNT

3.19 DSR-5.27

Providing and filling in position bitumen mix filler of Proportion 80 kg. ofhot bitumen , 1 kg. of cement and 0.25 cubic metre of coarse sand fordepth per expansion joints.

Cum 0.10

Total of sub-head (3.0)

4.0 6 BRICK WORK

4.01 DSR-6.34

Brick work with non modular fly ash bricks conforming to IS:12894,class designation 10 average compressive strength in super structureabove plinth level up to floor V level in :

a) 6.34.2 Cement mortar 1:6 (1 cement : 6 coarse sand) Cum 399.00

4.02 DSR-6.45

Half brick masonry with non modular fly ash bricks of class designation10, conformingio IS :12894, in super structure above plinth and uptofloor V level.

a) 6.45.2 Cement mortar 1:4 (1 cement :4 coarse sand) Sqm 339.00

4.03 DSR-6.15

Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars atevery third course of half brick masonry.

Sqm 339.00

Total of sub-head (4.0)

5.0 8 MARBLE WORK5.01 DSR-8.2 Providing and fixing 18 mm thick gang saw cut, mirror polished,

premoulded and prepolished, machine cut for kitchen platforms, vanitycounters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick basecement mortar 1:4 (1 cement : 4 coarse sand), joints treated with whitecement, mixed with matching pigment, epoxy touch ups, includingrubbing, curing, moulding and polishing to edges to give high glossfinish etc. complete at all levels.

a) 8.2.2 Granite of any colour and shadei) 8.2.2.2 Area of slab over 0.50 sqm sqm 25.00

WAPCOS Ltd.Signature of Bidder

S. NO. REF.NO. DESCRIPTION UNIT RATE QTY. AMOUNT

5.02 DSR-8.3 Providing edge moulding to 18 mm thick marble stone counters,Vanities etc., including machine polishing to edge to give high glossfinish etc. complete as per design approved by Engineer-in-Charge.

a) 8.3.2 Granite work Metre 41.00

5.03 DSR-8.4 Extra for fixing marble /granite stone, over and above correspondingbasic item, in facia and drops of width upto 150 mm with epoxy resinbased adhesive, including cleaning etc. complete.

Metre 41.00

5.04 DSR-8.5 Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location inmarble/ Granite/ stone work, including necessary holes for pillar tapsetc. including moulding, rubbing and polishing of cut edges etc.complete.

Each 19.00

5.05 DSR-8.10

Providing and fixing stone slab with table rubbed, edges rounded andpolished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinalpartitions by cutting a chase of appropriate width with chase cutter andembedding the stone in the chase with epoxy grout or with cementconcrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finishedsmooth.

a) 8.10.1 White Agaria Marble Stone Sqm 6.00

5.06 DSR-8.31

Providing and fixing Ist quality ceramic glazed wall tiles conforming toIS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black ofany size as approved by Engineer-in-Charge, in skirting, risers of stepsand dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matchingshade complete.

Sqm 479.00

Total of sub-head (5.0)

6.0 9 WOOD WORK & PVC WORK

WAPCOS Ltd.Signature of Bidder

S. NO. REF.NO. DESCRIPTION UNIT RATE QTY. AMOUNT

6.01 DSR-9.20

Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) decorative type, core of block board construction withframe of 1st class hard wood and well matched teak 3 ply veneeringwith vertical grains or cross bands and face veneers on both faces ofshutters.

a) 9.20.1 35 mm thick including ISI marked Stainless Steel butt hinges withnecessary screws

Sqm 88.00

6.02 DSR-9.23

Extra for providing lipping with 2nd class teak wood battens 25 mmminimum depth on all edges of flush door shutters (over all area ofdoor shutter to be measured).

Sqm 88.00

6.03 DSR-9.26

Extra for cutting rebate in flush door shutters (Total area of the shutterto be measured).

Sqm 88.00

6.04 DSR-9.83

Providing and fixing aluminium die cast body tubular type universalhydraulic door closer (having brand logo with ISI, IS : 3564, embossedon the body, door weight upto 35 kg and door width upto 700 mm),with necessary accessories and screws etc. complete.

Each 36.00

6.05 DSR-9.101

Providing and fixing aluminium hanging floor door stopper, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868)transparent or dyed to required colour and shade, with necessaryscrews etc. complete.

a) 9.101.2 Twin rubber stopper Each 43.00

6.06 DSR-9.102

Providing and fixing aluminium casement stays, ISI marked, anodised(anodic coating not less than grade AC 10 as per IS : 1868)transparent or dyed to required colour and shade, with necessaryscrews etc. complete.

Each 6.00

6.07 DSR-9.103

Providing and fixing bright finished brass 100 mm mortice latch andlock, ISI marked, with six levers and a pair of anodised (anodic coatingnot less than grade AC 10 as per IS : 1868) aluminium lever handlesofapproved quality with necessary screws etc. complete.

Each 43.00

WAPCOS Ltd.Signature of Bidder

S. NO. REF.NO. DESCRIPTION UNIT RATE QTY. AMOUNT

6.08 DSR-9.127

Providing & Fixing decorative high pressure laminated sheet of plain /wood grain in gloss / matt/ suede finish with high density protectivesurface layer and reverse side of adhesive bonding quality conformingto IS : 2046 Type S, including cost of adhesive of approved quality.

a) 9.127.2 1.0 mm thick Sqm 176.00

6.09 DSR-9.139

Providing and fixing panic bar / latch (Double point) fitted with a singlebody, Trim Latch & Lock on back side of the Panic Latch of reputedbrand and manufacture to be approved by the Engineer- in- charge, allcomplete.

Each 4.00

6.10 DSR-9.161

Providing and fixing fire resistant door frame of section 50 x 60 mm onhorizontal side & 35 x 60 mm on vertical sides having built in rebatemade out of 1.6 mm thick GI sheet ( Zinc coating not less than120gm/m²) suitable for mounting 120 min Fire Rated Glazed DoorShutters. The frame shall be filled with Mineral wool Insulation havingdensity min 96Kg/m³ . The frame will have a provision of G.I. Anchorfastners 14 nos ( 5 each on vertical style & 4 on horizontal style of sizeM10 x 80 ) suitable for fixing in the opening along with Factory madeTemplate for SS Ball Bearing Hinges of Size 100x89x3mm for fixing offire rated glazed shutter. The frame shall be finished with a approvedfire resistant primer or Powder coating of not less than 30 micron indesired shade as per the directions of Engineer - in- charge . (Cost ofSS ball bearing hinges is excluded).

Metre 192.00

WAPCOS Ltd.Signature of Bidder

S. NO. REF.NO. DESCRIPTION UNIT RATE QTY. AMOUNT

6.11 DSR-9.162

Providing and fixing 60 mm thick glazed fire resistant door shutters of120 min Fire Rating confirming to IS:3614 (Part II) or EN1634- 1:1999,tested and certified as per laboratory approved by Engineer-in-charge,with suitable mounting on door frame, consisting of vertical styles, toprail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60mm made out of 1.6mm thick G.I. sheet (zinc coating not less than120gm/m²) duly filled mineral wool insulation having density min 96kg/m³ and fixing with necessary stainless steel ball bearing hinges ofsize 100x89x3mm of approved make, including applying a coat ofapproved fire resistant primer or powder coating not less than 30micron etc all complete as per direction of Engineer-in-charge(panelling to be paid for seperately).

Sqm 6.00

Total of sub-head (6.0)

7.00 10 STEEL WORK

7.01 DSR-10.6

Supplying and fixing rolling shutters of approved make, made ofrequired size M.S. laths, interlocked together through their entirelength and jointed together at the end by end locks, mounted onspecially designed pipe shaft with brackets, side guides andarrangements for inside and outside locking with push and pulloperation complete, including the cost of providing and fixingnecessary 27.5 cm long wire springs manufactured from high tensilesteel wire of adequate strength conforming to IS: 4454 - part 1 andM.S. top cover of required thickness for rolling shutters.10.6.1 80x1.25 mm M.S. laths with 1.25 mm thick top cover Sqm 17.00

7.02 DSR-10.7

Providing and fixing ball bearing for rolling shutters. Each 4.00

7.03 DSR-10.8

Extra for providing mechanical device chain and crank operation foroperating rolling shutters.

a) 10.8.1 Exceeding 10.00 sqm and upto 16.80 sqm in the area Sqm 17.00

WAPCOS Ltd.Signature of Bidder

S. NO. REF.NO. DESCRIPTION UNIT RATE QTY. AMOUNT

7.04 DSR-10.9

Extra for providing grilled rolling shutters manufactured out of 8 mmdia M.S. bar instead of laths as per design approved by Engineer-in-charge, (area of grill to be measured).

Sqm 3.00

7.05 DSR-10.16

Steel work in built up tubular (round, square or rectangular hollowtubes etc.) trusses etc., including cutting, hoisting, fixing in positionand applying a priming coat of approved steel primer, includingwelding and bolted with special shaped washers etc. complete.

a) 10.16.1 Hot finished welded type tubes Kg 3466.00

7.06 DSR-10.18

Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box forceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5mm thick M.S. sheet with its top surface hacked for proper bonding,top lid shall be screwed into the cast iron/ M.S. sheet box by means of3.3 mm dia round headed screws, one lock at the corners. Clamp shallbe made of 12 mm dia M.S. bar bent to shape as per standarddrawing.

Each 40.00

7.07 DSR-10.28

Providing and fixing stainless steel ( Grade 304) railing made of Hollowtubes, channels, plates etc., including welding, grinding, buffing,polishing and making curvature (wherever required) and fitting thesame with necessary stainless steel nuts and bolts complete, i/c fixingthe railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor orthe side of waist slab with suitable arrangement as per approval ofEngineer-incharge, (for payment purpose only weight of stainless steelmembers shall be considered excluding fixing accessories such asnuts, bolts, fasteners etc.).

Kg 1518.00

Total of sub-head (7.0)

8.00 11 FLOORING

WAPCOS Ltd.Signature of Bidder

S. NO. REF.NO. DESCRIPTION UNIT RATE QTY. AMOUNT

8.01 DSR-11.3

Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 gradedstone aggregate) finished with a floating coat of neat cement, includingcement slurry, but excluding the cost of nosing of steps etc. complete.

a) 11.3.1 40 mm thick with 20 mm nominal size stone aggregate Sqm 20.00

8.02 DSR-11.4

52 mm thick cement concrete flooring with concrete hardener topping,under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarsesand : 4 graded stone aggregate 20 mm nominal size) and top layer12 mm thick cement hardener consisting of mix 1:2 (1 cementhardener mix : 2 graded stone aggregate 6 mm nominal size) byvolume, hardening compound mixed @ 2 litre per 50 kg of cement oras per manufacturer's specifications. This includes cost of cementslurry, but excluding the cost of nosing of steps etc. complete.

Sqm 20.00

8.03 DSR-11.6

Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1cement : 3 coarse sand), finished with a floating coat of neat cement.

a) 11.6.1 18 mm thick Sqm 15.00

8.04 DSR-11.13

Providing and fixing glass strips in joints of terrazo/ cement concretefloors.

a) 11.13.1 40 mm wide and 4 mm thick Metre 100.00

8.05 DSR-11.20

Chequerred precast cement concrete tiles 22 mm thick in footpath &courtyard, jointed with neat cement slurry mixed with pigment to matchthe shade of tiles, including rubbing and cleaning etc. complete, on 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).

a) 11.20.1 Light shade pigment using white cement Sqm 25.00

8.06 DSR-11.26

Kota stone slab flooring over 20 mm (average) thick base laid over andjointed with grey cement slurry mixed with pigment to match the shadeof the slab, including rubbing and polishing complete with base ofcement mortar 1 : 4 (1 cement : 4 coarse sand) :

a) 11.26.1 25 mm thick. Sqm 10.00

WAPCOS Ltd.Signature of Bidder

S. NO. REF.NO. DESCRIPTION UNIT RATE QTY. AMOUNT

8.07 DSR-11.37

Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st qualityconforming to IS : 15622 of approved make in colours such as White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4(1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matchingpigment etc., complete.

Sqm 213.00

8.08 DSR-11.41

Providing and laying vitrified floor tiles in different sizes (thickness tobe specified by the manufacturer) with water absorption less than0.08% and conforming to IS: 15622, of approved make, in all coloursand shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4coarse sand), jointing with grey cement slurry @ 3.3kg/sqm includinggrouting the joints with white cement and matching pigments etc.,complete.

11.41.2 Size of Tile 600x600 mm Sqm 383.00

8.09 DSR-11.46

Providing and laying Vitrified tiles in different sizes (thickness to bespecified by manufacturer), with water absorption less than 0.08 % andconforming to I.S. 15622, of approved make, in all colours & shade, inskirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqmincluding grouting the joint with white cement & matching pigments etc.complete.

11.46.2 Size of Tile 600x600 mm Sqm 2.00

8.10 DSR11.56

Providing and laying Polished Granite stone flooring in required designand patterns, in linear as well as curvilinear portions of the building allcomplete as per the architectural drawings with 18 mm thick stone slabover 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4coarse sand) laid and jointed with cement slurry and pointing withwhite cement slurry admixed with pigment of matching shade includingrubbing , curing and polishing etc. all complete as specified and asdirected by the Engineer-in-Charge.

WAPCOS Ltd.Signature of Bidder

S. NO. REF.NO. DESCRIPTION UNIT RATE QTY. AMOUNT

Polished Granite stone slab jet Black, Cherry Red, Elite Brown, CatEye or equivalent.

Sqm 383.00

Total of sub-head (8.0)

9.00 12 ROOFING

9.01 DSR-12.50

Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge)0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 gramsper sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxyprimer on both side of the sheet and polyester top coat 15-18 microns.Sheet should have protective guard film of 25 microns minimum toavoid scratches during transportation and should be supplied in singlelength upto 12 metre or as desired by Engineer-in-charge. The sheetshall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical orcurved surfaces, excluding the cost of purlins, rafters and trusses andincluding cutting to size and shape wherever required.

Sqm 1269.00

WAPCOS Ltd.Signature of Bidder

S. NO. REF.NO. DESCRIPTION UNIT RATE QTY. AMOUNT

9.02 DSR-12.45

Providing and fixing false ceiling at all height including providing andfixing of frame work made of special sections, power pressed fromM.S. sheets and galvanized with zinc coating of 120 gms/sqm (bothside inclusive) as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200mm centre to centre, one flange fixed to the ceiling with dash fastener12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleatfixed to the angle hangers of 25x10x0.50 mm of required length withnuts & bolts of required size and other end of angle hanger fixed withintermediate G.I. channels 45x15x0.9 mm running at the spacing of1200 mm centre to centre, to which the ceiling section 0.5 mm thickbottom wedge of 80 mm with tapered flanges of 26 mm each havinglips of 10.5 mm, at 450 mm centre to centre, shall be fixed in adirection perpendicular to G.I. intermediate channel with connectingclips made out of 2.64 mm dia x 230 mm long G.I. wire at everyjunction, including fixing perimeter channels 0.5 mm thick 27 mm highhaving flanges of 20 mm and 30 mm long, the perimeter of ceilingfixed to wall/partition with the help of rawl plugsat 450 mm centre, with 25mm long dry wall screws @ 230 mm interval,including fixing of gypsum board to ceiling section and perimeterchannel with the help of dry wall screws of size 3.5 x 25 mm at 230mm c/c, including jointing and finishing to a flush finish of tapered andsquare edges of the board with recommended jointing compound ,jointing tapes , finishing with jointing compound in 3 layers coveringupto 150 mm on both sides of joint and two coats of primer suitable forboard, all as per manufacturer's specification and also including thecost of making openings for light fittings, grills, diffusers, cutouts madewith frame of perimeter channels suitably fixed, all complete as perdrawings, specification and direction of the Engineer in Charge but12.45.1 12.5 mm thick tapered edge gypsum plain boardconforming to IS: 2095- (Part I) : 2011 (Board with BIScertification marks)

Sqm 1249.00

Total of sub-head (9.0)

10.00 13 FINISHINGPLASTER

WAPCOS Ltd.Signature of Bidder

S. NO. REF.NO. DESCRIPTION UNIT RATE QTY. AMOUNT

10.01 PL-4(i) 12mm. thick cement plaster (1:6) on brick work (Ground Floor) Sqm 491.0010.02 PL-4(iv) 12mm. thick cement plaster (1:6) on brick work (Inside 1st Floor) Sqm 363.0010.03 PL-4(v) 12mm. thick cement plaster (1:6) on brick work (Inside 2nd Floor) Sqm10.04 PL-14(i) 16 mm. thick cement plaster (1 :6) over brick or stone masonry Sqm 911.0010.05 PL-14(ii) 16 mm. thick cement plaster (1 :6) over brick or stone masonry

(Outside 1st Floor / below GL beyond 1.5m upto 4.5m depth)Sqm 415.00

10.06 PL-14(iii) 16 mm. thick cement plaster (1 :6) over brick or stone masonry(Outside 2nd Floor)

Sqm

10.07 PL-14(iv) 16 mm. thick cement plaster (1 :6) over brick or stone masonry (Inside1st Floor)

Sqm 260.00

10.08 PL-14(v) 16 mm. thick cement plaster (1 :6) over brick or stone masonry (Inside2nd Floor)

Sqm

PAINTING10.09 PAINT-1 Priming one coat with any approved primer including cost of all

labour, materials T & P with taxes, transportation etc all complete.i Rate per 1 sqm. With material (for steel work) Sqm 25.00ii Rate per 1 sqm. with materials (for wood work) Sqm 25.00iii Rate per 1 sqm. with materials (for plastered surface) Sqm 4838.00

PAINT-2 Enamel Painting one coat with any approved paint on new wood workincluding cost of all labour ,materials T & P with taxes, transportationetc all complete for steel work.

10.10 Rate per 1 sqm. With material Sqm 20.00PAINT-

3(i)Enamel Painting two coats with any approved paint including cost ofall labour, materials T & P with taxes, transportation etc all complete inGround Floor.

10.11 Rate per 1 sqm. With material Sqm 20.00PAINT-

3(ii)Enamel Painting two coats (Outside 1st Floor / below GL beyond 1.5mupto 4.5m depth)

10.12 Rate per 1 sqm. With material Sqm 20.00PAINT-

3(iii)Enamel Painting two coats (Outside 2nd Floor)

10.13 Rate per 1 sqm. With material Sqm 20.00PAINT-

3(iv)Enamel Painting two coats (Inside 1st Floor)

10.14 Rate per 1 sqm. With material Sqm 20.00

WAPCOS Ltd.Signature of Bidder

S. NO. REF.NO. DESCRIPTION UNIT RATE QTY. AMOUNT

PAINT-3(v)

Enamel Painting two coats (Inside 2nd Floor)

10.15 Rate per 1 sqm. With material Sqm 20.00PAINT-

19Wall painting 1 coat with plastic emulsion paint/Weather Coat ofapproved shade on old work to give an even shade.

10.16 Rate per 1 sqm. With material (Plastic Emulsion Paint) Sqm 50.0010.17 Rate per 1 sqm. With material (Weather Coat) Sqm 50.00

PAINT-20(i)

Wall painting 2 coats with Plastic Emulsion Paint/Weather Coat of approvedshade on new work to give an even shade in Ground Floor.

10.18 Rate per 1 sqm. With material Sqm 50.00PAINT-20(ii)

Wall painting 2 coats with plastic emulsion paint (Outside 1st Floor / below GLbeyond 1.5m upto 4.5m depth)

10.19 Rate per 1 sqm. With material Sqm 50.00PAINT-20(iii)

Wall painting 2 coats with plastic emulsion paint (Outside 2nd Floor)

10.20 Rate per 1 sqm. With material Sqm 50.00PAINT-20(iv)

Wall painting 2 coats with plastic emulsion paint (Inside 1st Floor)

10.21 Rate per 1 sqm. With material Sqm 50.00PAINT-20(v)

Wall painting 2 coats with plastic emulsion paint (Inside 2nd Floor)

10.22 Rate per 1 sqm. With material Sqm 50.00PAINT-

23Finishing plastered surfaces of walls with plaster of paris & marking smooth toreceive painting.

10.23 Rate per 1 sqm. With material Sqm 974.92PAINT-

23aFinishing plastered surfaces of walls with Berger Synthetic putty (interior wallputy) wall putty and making smooth to receive painting.

10.24 Rate per 1 sqm. With material Sqm 1462.3810.25 DSR-

13.712 mm cement plaster finished with a floating coat of neat cement ofmix :

a) 13.7.2 1:4 (1 cement: 4 fine sand) Sqm 50.00

10.26 DSR-13.37

White washing with lime to give an even shade :

a) 13.37.1 New work (three or more coats) Sqm 200.00

WAPCOS Ltd.Signature of Bidder

S. NO. REF.NO. DESCRIPTION UNIT RATE QTY. AMOUNT

10.27 DSR-13.41

Distempering with oil bound washable distemper of approved brandand manufacture to give an even shade :

a) 13.41.1 New work (two or more coats) over and including water thinnablepriming coat with cement primer

Sqm 1463.00

10.28 DSR13.44

Finishing walls with water proofing cement paint of required shade :

13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm) Sqm 975.00

10.29 DSR-13.45

Finishing walls with textured exterior paint of required shade :

a) 13.45.1 New work (Two or more coats applied @ 3.28 ltr/10 sqm) over andincluding priming coat of exterior primer applied @ 2.20kg/10 sqm

Sqm 50.00

10.30 DSR-13.52

Finishing with Epoxy paint (two or more coats) at all locations preparedand applied as per manufacturer's specifications including appropriatepriming coat, preparation of surface, etc. complete.

a) On steel work Sqm 50.00

Total of sub-head (10.0)

11.00 15 DISMANTLING AND DEMOLISHINGSITE CLEARANCE

11.01

S CLE-3

Clearing and grubbing road land including uprooting rank vegetation,grass, bushes, shrubs, saplings and trees girth up to 300 mm, removalof stumps of trees cut earlier and disposal of unserviceable materialsand stacking of serviceable material to be used or auctioned, up to alead of 1000 metres including removal and disposal of top organic soilnot exceeding 150 mm in thickness.

Hec 1.00

11.02 DISM-23 Dismantling and removing cement concrete including stacking theuseful materials for reuse and removing the debris within 50m

Cum 5.00

11.03 DISM-24 Dismantling and removing R.C.C.columns beams slab staircaselanding lintels including stacking the useful materials for reuse andremoving the debris within 50m lead

Cum 5.00

WAPCOS Ltd.Signature of Bidder

S. NO. REF.NO. DESCRIPTION UNIT RATE QTY. AMOUNT

11.04 DISM-25 Dismantling and removing R.C.C. Chajja, Shelves, fins and parapetincluding stacking the useful materials for reuse and removing thedebris within 50m lead.

Sqm 20.00

11.04 DISM-3 Dismantling brick or stone masonry in lime or cement mortar under3m. height including stacking the useful materials for reuse andremoving the debris within 50m. Lead

Cum 20.00

11.05 DISM-4 Dismantling brick or stone masonry in lime or cement mortar above3m. height including stacking the useful materials for reuse andremoving the debris within 50m. Lead

Cum 5.00

Total of sub-head (11.0)

12.0 Road Work

12.01 DSR-16.1

Preparation and consolidation of sub grade with power road roller of 8to 12 tonne capacity after excavating earth to an average of 22.5 cmdepth, dressing to camber and consolidating with road roller includingmaking good the undulations etc. and re-rolling the sub grade anddisposal of surplus earth with lead upto 50 metres.

Sqm 1902.00

12.02 DSR-16.18

Fencing with angle iron post placed at required distance embedded incement concrete blocks, every 15th post, last but one end post andcorner post shall be strutted on both sides and end post on one sideonly and provided with horizontal lines and two diagonals interwovenwith horizontal wires, of barbed wire weighing 9.38 kg per 100 m(minimum), between the two posts fitted and fixed with G.I. staples,turn buckles etc. complete. (Cost of posts, struts, earth work andconcrete work to be paid for separately). Payment to be made permetre cost of total length of barbed wire used.With G.I. barbed wire Meter 270.00

12.03 DSR-16.19

Supplying at site Angle iron post & strut of required size includingbottom to be split and bent at right angle in opposite direction for 10cm length and drilling holes upto 10 mm dia. etc. complete.

Kg 115.00

WAPCOS Ltd.Signature of Bidder

S. NO. REF.NO. DESCRIPTION UNIT RATE QTY. AMOUNT

12.04 DSR-16.70

Providing and fixing G.I. chain link fabric fencing of required width inmesh size 50x50 mm including strengthening with 2 mm dia wire ornuts, bolts and washers as required complete as per the direction ofEngineer-in-charge.

Sq m

16.70.2 Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia notless than 5 mm in required colour and shade

Sq m

12.05 DSR-16.68

Providing and laying 60mm thick faciory made cement concreteinterlocking paver block of M -30 grade made by block makingmachine with strong vibratory compaction, of approved s;ze, design &shape, laid in required colour and pattern over and including 50mmthick compacted bed of coarse sand, filling the joints with line sand etc.all complete as per the direction of Engineer-in-charge.

Sqm 86.00

12.06 DSR-16.69

Providing and laying at or near ground level factory made kerb stone ofM-25 grade cement concrete in position to the required line, level andcurvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand),including making joints with or without grooves (thickness of jointsexcept at sharp curve shall not to more than 5mm), including makingdrainage opening wherever required complete etc. as per Providingand laying at or near ground level factory made kerb stone of M-25grade cement concrete in position to the required line, level andcurvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand),including making joints with or without grooves (thickness of jointsexcept at sharp curve shall not to more than 5mm), including makingdrainage opening wherever required complete etc. as per

Cum 55.00

12.07 DSR-16.78

Construction of granular sub-base by providing close graded Materialconforming to specifications, mixing in a mechanical mix plant at OMC,carriage of mixed material by tippers to work site, for all leads & lifts,spreading in uniform layers of specified thickness with motor grader onprepared surface and compacting with vibratory power roller to achievethe desired density, complete as per specifications and directions ofEngineer-in-Charge.

16.78.1 With material conforming to Grade-I (size range 75 mm to 0.075 mm)having CBR Value-30

Cum 286.00

WAPCOS Ltd.Signature of Bidder

S. NO. REF.NO. DESCRIPTION UNIT RATE QTY. AMOUNT

12.08 DSR-16.79

Providing, laying, spreading and compacting graded stone aggregate(size range 53 mm to 0.075 mm ) to wet mix macadam (WMM)specification including premixing the material with water at OMC in forall leads & lifts, laying in uniform layers with mechanical paverfinisherin sub- base / base course on well prepared surface and compactingwith vibratory roller of 8 to 10 tonne capacity to achievethe desireddensity, complete as per specifications and directions of Engineer-in-Charge.

Cum 227.00

12.09 DSR-16.81

Providing and erecting 2.00 metre high temporary barricading at siteas per drawing/ direction of Engineer-in-Charge which includes writingand painting, arrangement for traffic diversion such as traffic signalsduring construction at site for day and night, glow lamps, reflectivesigns, marking, flags, caution tape as directed by the Engineer-inCharge. The barricading provided shall be retained in position at sitecontinuously i/c shifting of barricading from one location to anotherlocation as many times as required during the execution of the entirework till its completion. Rate include its maintenance for damages,painting, all incidentals, labour materials, equipments and worksrequired to execute the job. The barricading shall not be removedwithout prior approval of Engineer-in-Charge.(Note :- One time payment shall be made for providing barricadingfrom start of work till completion of work i/c shifting. The barricadingprovided shall remain to be the property of the contractor oncompletion of the work)

Meter

Total of sub-head (12.0)

13.00 21 ALUMINIUM WORK

WAPCOS Ltd.Signature of Bidder

S. NO. REF.NO. DESCRIPTION UNIT RATE QTY. AMOUNT

13.01 DSR-21.1

Providing and fixing aluminium work for doors, windows, ventilatorsand partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved makeconforming to IS: 733 and IS: 1285, fixing with dash fasteners ofrequired dia and size, including necessary filling up the gaps atjunctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required includingcleat angle, Aluminium snap beading for glazing / paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings andthe directions of Engineer-in-charge. (Glazing, paneling and dashfasteners to be paid for separately) :a) 21.1.1 For fixed portion (Including Louvers)

(i) 21.1.1.1 Anodised aluminium (anodised transparent or dyed to required shadeaccording to IS: 1868, Minimum anodic coating of grade AC 15)

Kg 618.00

13.02 DSR-21.3

Providing and fixing glazing in aluminium door, window, ventilatorshutters and partitions etc. with EPDM rubber / neoprene gasket etc.complete as per the architectural drawings and the directions ofEngineer-in-charge . (Cost of aluminium snap beading shall be paid inbasic item):

a) 21.3.2 With float glass panes of 5 mm thickness (weight not less than 12.50kg/ sqm)

Sqm 24.00

13.03 DSR-21.4

Providing and fixing double action hydraulic floor spring of approvedbrand and manufacture conforming to IS : 6315, having brand logoembossed on the body / plate with double spring mechanism and doorweight upto 125 kg, for doors, including cost of cutting floors,embedding in floors as required and making good the same matchingto the existing floor finishing and cover plates with brass pivot andsingle piece M.S. sheet outer box with slide plate etc. complete as perthe direction of Engineer-in-charge.

a) 21.4.1 With stainless steel cover plate minimum 1.25 mm thickness Each 8.00

WAPCOS Ltd.Signature of Bidder

S. NO. REF.NO. DESCRIPTION UNIT RATE QTY. AMOUNT

13.04 DSR-21.8

Filling the gap in between aluminium frame & adjacent RCC/ Brick/Stone work by providing weather silicon sealant over backer rod ofapproved quality as per architectural drawings and direction ofEngineer-in-charge complete.

a) 21.8.1 Upto 5mm depth and 5 mm width Metre 324.00

13.05 DSR-21.18

Providing and fixing 12 mm thick frameless toughened glass doorshutter of approved brand and manufacture, including providing andfixing top & bottom pivot & spring type fixing arrangement and makingnecessary holes etc. for fixing required door fittings, all complete asper direction of Engineer-in-charge (Door handle, lock and stopperetc.to be paid separately).

Sqm 88.00

Total of sub-head (14.0)

14.00 22 WATER PROOFING

14.01 DSR-22.22A

Providing and applying fibre reinforced elastomeric liquid waterproofing membrane with resilient acrylic polymers having SunReflectivity Index (SRI) of 105 on top of concrete roof in three [email protected] litre/ 10 sqm. One coat of self-priming of elastomericwaterproofing liquid (dilution with water in the ratio of 3:1) and twocoats of undiluted elastomeric waterproofing liquid (dry film thicknessof complete application/system not less than 500 microns). Theoperation shall be carried out after scrapping and properly cleaning thesurface to remove loose particles with wire brushes, complete in allrespect as per the direction of Engineer-in-Charge.

Sqm 543.00

14.02 DSR-22.3

Providing and laying water proofing treatment to vertical and horizontalsurfaces of depressed portions of W.C., kitchen and the like consistingof:

(i)

Ist course of applying cement slurry @ 4.4 kg/sqm mixed with waterproofing compound conforming to IS 2645 in recommendedproportions including rounding off junction of vertical and horizontalsurface.

WAPCOS Ltd.Signature of Bidder

S. NO. REF.NO. DESCRIPTION UNIT RATE QTY. AMOUNT

(ii)IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand)mixed with water proofing compound in recommended proportionincluding rounding off junction of vertical and horizontal surface.

(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg.per sqm of area.

(iv)IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVCsheet should be 100 mm wide and pasted to each other with bitumen@ 1.7 kg/ sqm).

Sqm 147.00

Total of sub-head (15.0)

15.0 HORTICULTURE & LANDSCAPING

15.01 DSR-2.1 Trenching in ordinary soil up to a depth of 60 cm including removal andstacking of serviceable materials and then disposing of surplus soil, byspreading and neatly leveling within a lead of 50 m and making up thetrenched area to proper levels by filling with earth or earth mixed withsludge or / and manure before and after flooding trench with water(excluding cost of imported earth, sludge or manure).

Cum 78.30

15.02 DSR-2.2 Supplying and stacking of good earth at site including royalty andcarriage upto 5 km complete (earth measured in stacks will be reducedby 20% for payment).

Cum 2636.00

15.03 DSR-2.4 Supplying and stacking at site dump manure from approved source,including carriage upto 5 km complete (manure measured in stacks willbe reduced by 8% for payment) :

2.4.1 Screened through sieve of I.S. designation 20 mm Cum 13.05

15.04 DSR-2.5 Rough dressing the trenched ground including breaking clods. Sqm 261.00

15.05 DSR-2.7 Fine dressing of the ground. Sqm 261.00

15.06 DSR-2.9 Mixing earth and sludge or manure in the required proportion specifiedor directed by the Officer-in-charge

Cum 26.10

WAPCOS Ltd.Signature of Bidder

S. NO. REF.NO. DESCRIPTION UNIT RATE QTY. AMOUNT

15.07 DSR-2.10

Grassing with selection No. 1 grass including watering andmaintenance of the lawn for 60 days or more till the grass forms a thicklawn, free from weeds and fit for mowing including supplying goodearth, if needed (the grass and earth shall be paid for separately).

2.10.1 In rows 5 cm apart in both directions Sqm 261.00

15.08 DSR-8.76

Supply and stacking of plant Thuja compacta of height 75-90 cm.,conical shaped, well formed with healthy foliage in earthen pots of size30 cm as per direction of the officer-in-charge.

Each 150.00

15.09 DSR-2.33

Felling trees of the girth (measured at a height of 1 m above groundlevel), including cutting of trunks and branches, removing the roots andstacking of serviceable material and disposal of unserviceablematerial.

2.33.1 Beyond 30 cm girth upto and including 60 cm girth Each 50.00

Total of sub-head (16.0)

16.00 NON SHEDULE ITEMS :- CIVIL

16.01 M.R-1 Providing and fixing of sinages of varying sizes and shapes usingstainless steel sheet of minimum 16G thickness brush finish includingengraving/etching of letters of required size filled with colour as desiredby engineer,fixing with ss screws on walls. All completed as permanufacturer's specifications and direction of Engineer-incharge.

Sqm 1.00

16.02 M.R-2 Providing fabricating and fixing of signages of varying sizes andshapes using three mm thick PVC sheet at base with self addhesivecoloured vinyl with graphicson top of glow tape complete includingfixing on wall with screws and washers or hanging on ceiling with GIchain/GI Bar complete as per manufacturer's specifications anddirections of Engineer.

SQM 0.50

WAPCOS Ltd.Signature of Bidder

S. NO. REF.NO. DESCRIPTION UNIT RATE QTY. AMOUNT

16.03 M.R-3 Finishing the top concrete surface by providing vacuum dewateringsystem "Trimix" including finishing the top using power trowels to asmooth and fair surface.

SQM 1188.00

16.04 M.R-4 Providing and fixing ISI Marked Stainless Steel round type 250mmlong tower bolts in required colour or shade, with necessary screwsetc. complete :

Each 56.00

16.05 M.R-5 Providing and fixing ISI Marked Stainless Steel round type 150mmlong tower bolts in required colour or shade, with necessary screwsetc. complete :

Each 50.00

16.06 M.R-6 Providing and fixing Stainless Steel Pull Handle, ISI Marked 150mm x16mmØ in required colour or shade, with necessary screws etc.complete :

Each 106.00

16.07 M.R-7 Providing and fixing Maple wood or equivalent ( As approved byengineer in charge) flooring 20  mm thick 83 mm wide strips of varyinglength from 250 mm to 1800 mm joined by tongue and groove jointover 38 mm x 63 mm Pinewood / Fir or spruce sleepers at 230 mm c/cwith 19 mm power pads at 250 mm c/c. The entire flooring shall have a6 mm thick polyethylene vapour barrier over IPS floor. The flooringshall be EN tested and World squash federation approved. Theflooring shall machine sanded to make it non slip finish

Sqm 1116.00

16.08 M.R-12 Brick work with non modular fly ash bricks conforming to IS:12894,class designation 10 average compressive strength in foundation andplinth in Cement Mortar 1:6 ( 1 Cement: 6 Coarse sand)

Cum 85.00

WAPCOS Ltd.Signature of Bidder

S. NO. REF.NO. DESCRIPTION UNIT RATE QTY. AMOUNT

16.09 M.R-13 Providing & Fixing of Mineral Fiber Acoustical Suspended CeilingSystem with Dune Supreme (Bevelled Tegular) Edge Tiles With 15mmExposed GRID.The tiles should have Humidity Resistance (RH) of 99%, NRC 0.5,Light Reflectance ≥85%, Thermal Conductivity k = 0.06 w/m K, ColorWhite, Fire Performance Euroclass A2- S1, d0 in module size of 600 x600 x 15mm , suitable for Green Building application, with Recycledcontent of 44%.The tile shall be laid on Suprafine 32 with 15 mm wide T - sectionflanges color white having rotary stitching on all T sections i.e. theMain Runner, 1200 mm & 600 mm Cross Tees with a web height of38mm and a load carrying capacity of 14 Kgs/M2 & minimum pull outstrength of 100 Kgs. The T Sections have a Galvanizing of 90 gramsper M2 and need to be installed with Suspension system.INSTALLATION: To comprise main runner spaced at 1200mm centressecurely fixed to the structural soffit at 1200mm maximum centre. TheFirst/Last suspension system at the end of each main runner shouldnot be greater than 450mm from the adjacent wall.Flush fitting 1200mm long cross tees to be interlocked between mainrunners at 600mm centre to form 1200 x 600 mm module. Cut crosstees longer than 600mm require independent support. 600 x 600mmmodule to be formed by fitting 600mm long flush fitting cross teescentrally between the 1200 mm cross tees.Perimeter trim to be wall angles of size 3000x19x19mm, secured towalls at 450 mm maximum centres.SUSPENSION SYSTEM accessories manufactured and suppliedconsisting of M6 Anchor Fasteners with Vertical Hangers made ofGalvanised steel of size 26 x 26 x 25 x 1.2mm with a GalvanisedThickness of 80gsm, A pre Straightened Hanger wire of dia – 2.5 mm

Sqm 1249.00

WAPCOS Ltd.Signature of Bidder

S. NO. REF.NO. DESCRIPTION UNIT RATE QTY. AMOUNT

16.10 M.R-14 Providing and placing in position 6.7 MM thick pre-fabricated sportssurface, total thickness 6.7 mm EN-428 with 1.3mm top layer, weightpsqmtr EN-430-3.8kg, closed sell double foam, Tech surfaceprotection, EN14904 (Category P1), EN ISO717-2 impact soundinsulation-22DB, Thermal resistance m2k/w 0.08, reaction to fire-meets European norms EN 13501-cf1-s2 formaldehyde emission-noformaldehyde, pentachlorphenol-no pentachlorphenol, Friction EN13036-4-80-110, shock absorption EN-14808-33%, vertical dorfmationEN-14809-MM-0.8, Ball rebound EN-12235-99%, specular gloss EN-2813-<30, Dimensional stability EN-434-+-0.2%, indentation resistanceEN-1516-0.19MM, resistance to rolling load EN-1569 (N)-1500, colourfastness ISO 105 B02-6, chemical resistance EN-423-no change,abration resistance EN ISO5470-1-mg/1000cycles-<250-T groupAntimicrobial treatment-treated, Environmental attributes-solvent andheavy metal free-no periodic renewal needed. Roll form-2*15mtr.Certified by FIBA, BWF (Elite Class) & IHF.Product cames warranty for10 years against the manufacturing defects. The work shall be carriedout as per specifications, drawings and as per direction of the engineer-in-charge.

Sqm 56.00

WAPCOS Ltd.Signature of Bidder

S. NO. REF.NO. DESCRIPTION UNIT RATE QTY. AMOUNT

16.11 M.R-15 Supply of structural steel and fabrication to transportation of structuralsteel,including zinc primer with 100 DP Enamel paint 2 or morecoats(Colour should be approved from Engineer In charge) and itserection at site .Steel conforming to IS:2062-2006, grade Fe 410B &AS 1397-1993 grade G345, as per approved shop drawings & madeup of built-up section of HTS/ MS plates,Pipe/ tubular section, angles,channels etc. of various thicknesses and sizes. Welding shall be donewith electrode as per client approved drawing. The fabrication costincludes welding components, welding consumables, cutting, shaping,holding, welding by fillet or butt welds, post weld treatments, inspectionand testing, connections of all types of ties, stiffeners, packing ,diaphragm, steel dirt, shop welding, shop rivets, field rivets, templates,jigs, fixtures, back up supports, accessories etc, and making eachmember for site identification and transporting various componentsfrom fabrication yard (if workshop is not at the site) to The site inpackages, bundles and other means with due care and safeguards asdescribed in the specifications, including loading, unloading, sorting,member wise, systematic matching etc. complete with contractor's ownlabour, material, tools & plants with initial coats of zinc chromatepriming(except on zed purloins) conforming to relevant IS specificationand three subsequent coats of aluminium paint / any other paint asapproved by the engineer of approved quality conforming to IS:2339after final erection on all surfaces complete with all leads & lifts andtaxes complete in all aspect. Detail fabrication drawings have to beprepared by the contractor based on the design/drawings and gotapproved from recognised Engg. college/university and to be vetted byreputed Govt. Engg college /University. Mode measurement as perannexure -1 of BOQ(Volume-II)For structural steel conforming to IS:2062-2006 Fe 410 B ( E 250Quality BO)For ZED Purlins (of 2.4mm BMT and Grade G345, Z 275) conformingto AS 1397-1993 ( purlins manufactured of 2.4 mm BMT GalvanizedSteel having minimum 345 Mpa yield strength with a Zinc coating of275 GSM total on both side conforming to ASTM A607. The purlinsare to be designed in accordance with AISI 96).

WAPCOS Ltd.Signature of Bidder

S. NO. REF.NO. DESCRIPTION UNIT RATE QTY. AMOUNT

Complete Pre-Engineered Building (PEB) Shed in all respects as perrelevant tender drawings and technical specifications, approved shopdrawings and / or instructions. The contractor shall be responsible fordesign and proof checking by recognised Govt. Engg college/universityapproved by the employer. The contractor shall submit GADs,architectural drawings of the hall for approval of the Employer as perkey dates. After approval of GAD/architectural drawings, the contractorshall submit design basis report, structural design and drawingsincluding foundation design based on soil investigation report of RVNL.Thereafter, the contractor shall submit complete proof checked designand drawings including foundation details from a recognisedGovernment Engineering College/ University (with prior approval of theEmployer) as per key dates.Rate is inclusive of complete design, drawing and proof checking andno separate payment will be made on this account. Rate is inclusive ofall materials including wastages, all consumables, fasteners, bothtemporary and permanent stages of work, all temporary stays, labour,temporary works including staging, scaffolding, tools, plant andequipment, and costs of all incidentals and necessary testing ofmaterial, workmanship etc including cost of sand blasting, all primerspainting as per specifications and as per instruction of the employer.Supply, fabrication, transportation, painting, erection of all structuralsteel works and items required for completion PEB shed includingpurlins, rafters, gantry, catwalk, stairs, frames, fasteners, etc as perproof checked design and drawings. The rate shall include supply,fastening, cutting, drilling, handling, riveting/ welding with supply ofelectrode, rivet, bolts and nuts, bituminous washer, supply of all labour,materials, tools and plants, scaffolding, staging complete in all respect.For assurance of quality of PEB Structure most of the fabrication willbe done in contractor's workshop/factory premises located other thanwork site.

Tonne 86.00

WAPCOS Ltd.Signature of Bidder

S. NO. REF.NO. DESCRIPTION UNIT RATE QTY. AMOUNT

16.12 M.R-17 Providing and fixing factory assembled 50mm thick PUFF(overallaverage density 40kg/cu.m +/- 2 kg/cum as per IS: 11239 Part-2)sandwiched panels ahall be provided. These panels shall be made ofPUFF insulation sandwiched between two high tensile steel sheetseach of 0.5 mm thickness. The material of sheets shall confirm toASTM 792 M with minimum yield strength of 340 Mpa. However,higher grades of steel may be supplied wiyjout any further costimplication.The steel shall be provided with hot dip coating shall be minimum200gm/Sq.m inclusive of both sides. The tolerance of base metalthickness (BMT) of steel shall be as per IS 16163. After hot dip coatingof zinc aluminium alloy, the sheet shall be provided with steel primerand silicon modified polyster (SMP) paint. The total thickness of primerand paint shall be 40 microns inclusive of both sides (TCT) comprisingod 20 microns of SMP paint on top surface and 10 microns of backercoat (polyster coat) on back surface over 5 micron thick primer eachon both surface swith inorganic pigments coated free from heavymetals. All work should complete as per drawing and satisfaction of

Sqm 1250.00

16.13 M.R-19 STRUCTURAL CURTAIN WALL GLAZINGDesign, Supply & Installation of curtain wall glazing members for awind pressure of 1.25 KN/Sq.m.Providing and fixing of semi unitised structural curtain glazing as perelevation drawings enclosed with 8.0mm thick toughened glass usingheavy duty aluminium extruded built up profiles. The standard glasspanel shall be installed as shown in elevations, glass panels shall befree from any scratch / tong marks.The aluminum glazing members of curtain glazing (Mullion &Transome) to be designed for a wind pressure of 1.25 KN/Sq.m. Thedesign of the curtain glazing system is to be based on I.S.:875 parts IIIfor required wind pressure and use of aluminium section alloy is as perI.S.:8147. System is to be designed considering thermal movements,air infiltration, water penetration, seismic movement and structuralmovement with toughened glass.

WAPCOS Ltd.Signature of Bidder

S. NO. REF.NO. DESCRIPTION UNIT RATE QTY. AMOUNT

Specially designed aluminum mullions and transoms of extrudedaluminum sections shall be of 63400 WP alloy with chemicalcomposition and mechanical properties as per IS: 733:1983 and I.S.1285:2002.All the aluminum sections / profiles shall be pure polyester powdercoated to 60 microns the. / Natural anodized to AC 20-25 grades asper I.S.:1868 of approved color OR as per direction of the Engineer –in – charge.All aluminum sections / profiles shall be wrapped with protective tapesduring delivery at site to provide safety against external scratcheswhile loading and unloading. (Protective Tapes to be removed as perthe instructions of Engineer -In-charge.The anchoring / bracing of the curtain glazing to the R.C.C. slab /beams / columns shall be done with non-corrosive galvanized 6mmthick m.s.brackets of approved design, (Galvanising shall beconforming to IS:4759-1996 upto 610 gms. per Sqm., 80-90 micronthickness) with two numbers on each beam, one normal bracket andone restrain bracket. (design / sample for extended bracket to besubmitted for approval) and including providing member and bracket(including providing and fixing of aluminum shims of variousthickness to adjust the beam level/ line variations) with SS dashfasteners of min. 12mm dia. and depth of 70 -80 mm in the concreteand to withstand the dead load of the curtain walls as well as stressesdue to wind pressure etc.The glazing frame shall be aligned for the entire height and for theentire width of each Transom by laser beam equipment to ensure 100percent 'X' axis and 'Y' axis alignment.The glazing frame work shall be provided with approved in-builtventilation and drainage system and the entire joint must be properlysealed with weather silicon to make the joint water tight. The details forin-built ventilation system to be submitted by the contractor and gotapproved by the Architect.The periphery shall be sealed both from inside and outside with siliconweather sealant to make the glazings water/ airtight.

WAPCOS Ltd.Signature of Bidder

S. NO. REF.NO. DESCRIPTION UNIT RATE QTY. AMOUNT

Gaps up to 10 mm between the peripheral aluminum member (endmullion) and masonry / R.C.C. / Stone shall be sealed by insertingadequate size of backer rod and weather silicon. Wherever the gapsare expected to be more than 10 mm, shall be sealed by providing andfixing of 2mm thick aluminum sheet flashings bent to required profileas per site, aluminium flashing sheet shall be pure polyester powdercoated to 60 Micron thickness in approved shade / colour or as perinstruction of E.I.C.. Detailed drawing of the flashings to be submittedby the contractor as per the site conditions for the approval ofEngineer-in charge.Flashing shall be provided at Soffit Level and Sill Level made out of 2mm thick Aluminium Sheet, Pure Polyester Powder Coated to 50microns thickness / anodised to 20 - 25 microns in approved colour,bent to required profile and shape. Fixing details shall be got approvedin shop drawing for all flashing to be submitted by the Glazingcontractor for the approval of the Architect including providing andapplication of silicon sealant at both edges of the flashing.

Cost of 8mm thick toughened glass including the labour element forcutting of glass stacking , carrying to heights and fixing in appropriatelocations is to be included in the rate.Warranty for structural silicone adhesion shall be got approved fromthe architect / engineer in charge to cover all risks against any failureof glass for a period of 15 years and shall be submitted to the architect/ engineer in charge on completion of the worksStructural glazing shall be installed with 8 mm thick toughened glassglazing The whole assembly is fixed to Aluminim framework bystainless steel screws and the periphery gap between the GI sheetframe & aluminium frame work to be sealed by silicon weather sealantwith backer rod. The SGU/ DGU shall be fixed at 300mm C/C to themullion/ transom by S.S. bolt.

Sqm 44.00

16.14 M.R-20 Demolishing for R.C.C. Slab core cutting for 150mm dia work bymechanical means/ including stacking of serviceable material anddisposal of unserviceable material within 50 metres lead as perdirection of Engineer-in-charge.

Nos. 5.00

WAPCOS Ltd.Signature of Bidder

S. NO. REF.NO. DESCRIPTION UNIT RATE QTY. AMOUNT

16.15 M.R-21 Demolishing for R.C.C. Slab core cutting for 100mm dia work bymechanical means/ including stacking of serviceable material anddisposal of unserviceable material within 50 metres lead as perdirection of Engineer-in-charge.

Nos. 5.00

16.16 M.R-22 Supplying and fixing Floor mounted Seat (440x440x400mm) made withblow moulded, HDPE(High density polyethylene, Anti UVprotection).The Seat is attached directly to a corrosion resistantgalvanized pipes by means of four tamper proof bolts and steelclamps.The pipe support system has the capability to be fixed to treador riser.The seat base and back is ergonomically designed to providemaximum user comfort.The seat incorporates a full lower back toeliminate interference from the feet of the people behind.The seat isguaranteed to maintain its original color with minimal fading for a twoyear guarantee period and incorporates slot to assist with drainage ofwater.A single or two digit numbering system can be supplied.Aisleend of row identification etched plates of size 100 x 120 mm with lettersize of 65 mm will be supplied.Fixings Two Galvanized Pipe beams willbe supported with Die casted Aluminum powder coated bracket shallbe fixed by a minimum of two 2 Hilti M8 x 40 bolts.anchors orequivalent installed as per manufacturers specifications.All steel elements shall be- hot-rolled plates complying with AS3678.-Aluminum Die casted brackets. and Welding shall be carried out inaccordance with AS1554.1.Pipes should be Hot dip galvanized.

Each 500.00

16.17 M.R-23 Providing and fixing 8mm thick Laminated wooden Flooring made fromHigh Density Fiber Board AC4 Class Category Premium Planked orequivalent in Greenply/Action Tesa/ Pergo/Alstone in similar designand specification complete in all respect with 2mm thick underlay andpolythene as per the direction of Engineer in charge.

Sqm 40.00

WAPCOS Ltd.Signature of Bidder

S.NO. DESCRIPTION AMOUNT1 CHAPTER 1: HT CABLE & TERMINATION -

2 CHAPTER 2: HT PANEL -

3 CHAPTER 3: TRANSFORMER (200KVA OIL FILLED) -

4 CHAPTER 4: DG SET (200KVA RADIATOR COOLED) -

5 CHAPTER 5: LT PANELS -

6 CHAPTER 6 : UPS -

7 CHAPTER 7: LT CABLES & TERMINATIONS -

8 CHAPTER 8: CABLES MANAGEMENT -

9 CHAPTER 9: DISTRIBUTION BOARD -

10 CHAPTER 10: WIRING -

11 CHAPTER 11: EARTHING & LIGHTNING PROTECTION -

12 CHAPTER 12: INTERNAL & EXTERNAL LIGHTING FIXTURES AND FANS -

13 CHAPTER 13: CIVIL WORKS -14 CHAPTER-14 : STURUCTURED CABLING FOR DATA AND NETWORKING -

15 CHAPTER-15: IP BASED CCTV SYSTEM -

16 CHAPTER-16 : FIRE ALARM & PUBLIC ADDRESS SYSTEM -

TOTAL AMOUNT IN RUPEES -

GRAND TOTAL AMOUNT IN RUPEES (OSR + DSR + NDSR)

PROJECT - CONSTRUCTION OF MULTIPURPOSE INDOOR HALL AT KALINGA SPORTS COMPLEX,BHUBANESWAR, ODISHA

SUMMARY OF WORKS (ELECTRICAL WORKS)

WAPCOS Ltd.Signature of Bidder

Ref. No. S.NO. DESCRIPTION UNIT RATE QUANTITY AMOUNT1 CHAPTER 1: HT CABLE & TERMINATION

1.1

Supplying, testing and commissioning of following size 3 core , 11KV/11KV(unearthed) grade, heavy duty XLPE insulated, FRLS type, aluminiumarmoured cables suitable for 11kV, 50Hz, AC system with inner and outer PVCsheath, outer sheath provided with FRLS insulation, galvanised steel flatarmouring and with all components as mentioned in BOQ, specifications andschedule, complete as required.

MR 1 1.1.1 300 sq. mm Metre 100 -

10.4 1.2

Supplying and making indoor cable end termination with heat shrinkablejointing kit complete with all accessories including lugs suitable for followingsize of 3 core, XLPE aluminium conductor cable of 11 kV grade as required.

10.4.4 1.2.1 300 sq. mm Each 1 -

10.5 1.3

Supplying and making outdoor cable end termination with heat shrinkablejointing kit complete with all accessories including lugs suitable for followingsize of 3 core, XLPE aluminium conductor cable of 11 kV grade as required.

10.5.4 1.3.1 300 sq. mm Each 5 -

8.4 1.4Laying of one number PVC insulated and PVC sheathed / XLPE power cable of11 kV grade of following size in the existing masonry open duct as required.

8.4.2 1.4.1 Above 120 sq. mm and upto 400 sq. mm Metre 100 -Subtotal carried over to summary -

2 CHAPTER 2: HT PANELNotes :- Cubicle shall be type tested for internal arc for all compartment for 25KA for1sec as per IEC 62271-200.- Cubicle manufacturer should also be the manufacturer of VacuumInterrupters used.

MR 2 2.2

01 NO. INCOMING/OUTGOING (NEAR TRANSFORMER)Supplying, installation , testing and commissioning of totally enclosed, fullyextendable from both sides,roll on floor type, metal clad, indoor type,horizontal drawout horizontal isolation type, dust/ corrosion/vermin proof ,HT panel suitable for 12kV, 630A. 25kA for 3 sec, internal arc tested ( from allsides viz. front, lateral and rear) for rated fault current rating for 1s,fabricated out of CRCA / Aluzinc sheet steel throughout (thickness as pertype test design), mounted upon suitable size ISMC-100 channel, properlygrouted, with all necessary internal power and control wiring complete withterminal blocks marking and ferruling including dc circuit wiring from powerpack to respective panel (power pack shall be a part of HT panel and shall beincluded in cost), interpanel and intrapanel ac/dc circuit wiring ,copperbusbars of suitable ratings for phase as well as earth, metallic seperations ofCRCA / Aluzinc sheet (thickness as per type test design) between eachswitchgear and control gear compartment, approved danger and arc flashsignages and with all components as mentioned in BOQ, specifications andschedule, complete with following as required.

Each 1 -

Surge arrester (1 Nos.)9kV,10kA, metal oxide varistor type surge arrestor suitable fo both lightningand switching surges,complete with its bushings and earthing terminationsetc. as required.

PROJECT - CONSTRUCTION OF MULTIPURPOSE INDOOR HALL AT KALINGA SPORTS COMPLEX, BHUBANESWAR, ODISHA

DETAILED ESTIMATE (ELECTRICAL WORKS)

WAPCOS Ltd.Signature of Bidder

Ref. No. S.NO. DESCRIPTION UNIT RATE QUANTITY AMOUNTLine PT (1 Nos.)2 core line mounted, fixed type,3 phase (3 x 1 phase), cast resin, potentialtransformer with rated turn/voltage ratio of 11000/(1.732):110/(1.732),rated burden of 50 VA, 11kV rated inbuilt primary side fuse,110V ratedsecondary and tertiary side fuses complete with isolating plugs as required.Core 1 : CL 0.5, star connected with neutral grounded for metering andindications.Core 2 : CL 3P, star connected with neutral grounded for protections.

VCB (1 Nos.)11kV, 50Hz, 630A, 350 MVA, 3P, 25kA for 3 sec rated, drawout type, VCBbreaker panel with 110 volts DC closing and tripping coils, with a provision ofsecondary trip coil and 230 Volts AC spring charging motor, locking magnet,inbuilt antipumping relay, potential free NO & NC contacts required inaddition to 4 spare NO and 4 spare NC contacts, door interlocking, rackinginterlocking and any other controls or interlocks as described in specificationsor schedules, solenoids, TNC switch and inbuilt earth switch, connected onthe line side of VCB and mechanically interlocked with VCB, complete asrequired.Indication lamps (12 Nos.)LED type phase indication lamps suitable for 110V,50Hz AC (red, yellow, blue)LED type Indication lamps for breaker, suitable for 110V DC supply (on, off,trip, test, service, spring charge,TCH,earth switch on)LED type Indication lamps for DC healthy, suitable for 110V DC supply

Micro Processor based non directional IDMT instantaneous relay modulehaving following inbuilt functions:3 nos. Overcurrent protection with settings from 50% to 200% and earth faultprotection with settings from (10 - 40%), under voltage ( with dead bandbypass feature), over load protection, frequency based protection , phasesequence protections, the relay module shall be suitable to record and storeat least 100 events with date and time with last five fault records stored innonvolatile memory and with self supervision function, 4 spare digital binaryinputs and 4 spare digital output contacts in addition to those required as perthe scheme, modbus communication protocol, breaker control (on/off)complete as required. - 1Set.

CT chamber with, single phase, Single ratio cast resin CT, 15VA burden withcore for protection (CL-5P10) and of 80/5+5+5 A ratio. - 3 Nos.Electro-mechanical relay:Hinged armature type electromechanical master trip (lockout) relay completewith assembly- 1 Nos.Hinged armature type trip circuit supervision relay complete with assembly- 1Nos.Hinged armature type dc fail relay complete with assembly- 1 Nos.PT fuse failure relay - 1 Nos.Metering (1 Nos.)Multifunction meter with inbuilt selector switch for measurement of current,voltage, power factor, KVA, kVAh, KVArh, KVAR, frequency, %THD (upto 15thorder), THDi,THDv,KWHr (both line and phase) and maximum demandrecording and indicating etc. complete as per specifications, RS-485 portalong with 3No. 11kV ,100/1A, 2.5VA, CL-1 current transformer as required -1 No.0-11000 volts analog type voltmeter with selector switch for Vr, Vy, Vb - 1 No.

WAPCOS Ltd.Signature of Bidder

Ref. No. S.NO. DESCRIPTION UNIT RATE QUANTITY AMOUNTNumeric relay module (for safe tripping of transformer's 11kV feed breaker)with LCD dislpay having following inbuilt protection functions :Restricted earth fault protection of transformer, high winding temperature,suitable to record and store at least 100 events with date and time with lastfive fault records stored in nonvolatile memory and with self supervisionfunction, 4 spare digital binary inputs and 4 spare digital output contacts inaddition to those required as per the scheme, modbus communicationprotocol with RS-485 Port, breaker control (on/off) along with 3No. 11kV,100/1A, 2.5VA, CL-5P10 current transformers, complete as required. - 2 Nos.

Required Auxiliary relays for Bucholtz, Oil ,WTI (Winding temperatureindication with alarm & trip) - 1 Set for each transformerEmergency trip button on front door at an accessible height -1 Nos.Selector type auto / manual switch -1 Nos.230 volt, 50Hz,AC operated Hooter with noise level of 80db at every 3 metreswith acknowledge and reset push button-1 Nos.16-window microprocessor based annunciation panel with visual LEDindicator complete as per specifications and schedule as required. - 1 Nos.All control wiring with protection & test terminal block as required - 1 SetStrip heater with thermostat for moisture absorption. - 1 SetSuitable for connection to 3 core x 300 sq.mm. Cross linked polyethylene(XLPE) 11KV cables or as called for.Subtotal carried over to summary -

3 CHAPTER 3: TRANSFORMER (200KVA OIL FILLED)

MR 3 3.1

Supplying, installation testing and commissioning of, outdoor type, oil cooleddistribution transformer, suitable for 3 phase, 50HZ, AC supply with ratedpower of 200kVA complete with the following standard, mountings, fittings,approved danger and arc flash signages and with all components &accessories as mentioned in BOQ, specifications and schedule, complete asrequired.The Transformer must confirm to the IS standards specified in the technicalspecifications.

Each 1 -

Rated Turn / Voltage ratio - 11kV/415VVector Group - Dyn11Cooling - Oil Natural Air Natural (ONAN) mechanismCore - Core made of good quality CRGO, double wound copperInsulation Class - 'A'Temperature rise : 50/55 Deg. (oil / winding)Impedance - 4.50%Off load tap changing links with Taps on HV for HV variation : +2.5 to - 5 % inthe steps of 2.5Cable termination box with disconnecting facility for 11 KV XLPE cable at 11KV side.Cable termination box with disconnecting facility for 1.1 KV XLPE cable at0.415 KV side.Provision for CTs for REF protection shall be provided (CTs shall be providedloose as free issue item by the LT Panel Manufactrure to be fixed byTransformer Manufacturer either at site or works as the case may be)The transformer shall be supplied with Standard fittings as per specificationsincluding the following :

a) Conservator with drain valve.b) Silicagel breather with oil seal.

c) First filling of oil as per IS 335 including make up during installation oftransformer plus 10% extra oil. To be supplied - in a container.

d) Thermometer pocket with pluge) Air release plugf) Inspection coverg) Top filter brass gate valve - 1 no.h) Removable Lifting lugs and Jack lifting pad support

WAPCOS Ltd.Signature of Bidder

Ref. No. S.NO. DESCRIPTION UNIT RATE QUANTITY AMOUNT

i) Earthing terminals - 2 nos.for body earth and neutral earthing bushingterminal on transformer top cover.

j) Radiator with top and bottom shut off brass gate valvesk) Rating and Diagram plate.l) Bi-directional Plain/Flanged Rollers.

m) Drain cum bottom filter valve - 1 no.n) Explosion vent with double diaphragm and sight glass.o) Buchholtz relay with shut off valve.

p) 100 mm dial magnetic oil level gauge with max pointer and low level alarmcontacts.

q) 150 mm dial oil temperature indicator (OTI) with max pointer and 2 sets ofContact for Alarm & trip.

r)150 mm dial winding temperature indicator (WTI) with max pointer & 2 setsof contacts for alarm & trip.

s) Magnetic oil level indicator with annunciation.

t)Marshalling box with watertight lockable cover lid, lamp point, 15Aswitchsocket oulet point and all associated accessories as per schedules andspecifications.NOTE :- Item nos. o, p, q, r, s, t shall be suitable for termination of multicore(minimum 6 core 2.5 sq.mm. Copper ) conductor armoured cable connectingbetween respective equipment to terminal block in marshalling box toannunciation window panel and to main breaker as required.( TheTransformer losses shall be as per ECBC guideline).The total Transformer losses at Rated load, Voltage & frequency to be as perIS 1180 (Energy Efficiency Level 2 or better)Subtotal carried over to summary -

4 CHAPTER 4: DG SET (200KVA RADIATOR COOLED)

4.1

Design, manufacturing, testing at works, supply installation, testing andcommissioning of DG Set with acoustic Enclosure including requiredventilation system of following rating for site conditions, complete with DieselEngine, base frame, lube oil system, Radiator, required batteries, governor,instrumentation, exhaust silencers (Hospital type) including Aluminiumcladding, alarms, engine mounted control panel, utility piping, anti vibrationpads, Alternator direct/flexible coupled to Engine along with static excitationsystem and AVR panel and all required accessories complete as required andas per specifications.The scope of work does not include AMF panel, cablingand earthing. . Cable Box to be provided for termination of required Al. Cable.

The DG sets shall be provided with Genset Controller as also mentionedabove for AMF/Auto/Manual synchronising, Auto load sharing and havingElectrical and Mechanical parameter monitoring, Electrical protection (Underand Over frequency & Voltage, Overload (KW), Over Current, Short Circuit,Reverse Power, Excitation failure, CT for restricted earth fault protection anddroop compensation

MR 4 a 200 KVA Set 1 -

4.2

EXHAUST PIPING:Supply, laying and fixing of following sizes of MS B Class piping( Tatas, Jindal(Hissar),IST) with bends etc. for Exhaust of DG Sets including providingsuitable self supporting arrangement etc. and supplying & fixing 75 mm thickmineral wool insulation of 150 Kg per cubic meter density on all sides ofExhaust pipe and silencer with chicken mesh wrapping and aluminiumcladding with aluminium sheet of 26 SWG,suitable for outdoor installationcomplete as required and as per specification. The DG Exhaust shall be takenalong the building supported from the wall however scope includes buildingrequired structure for reaching up to the shaft.

MR 5 a. 200mm (NB) MS pipe Mtr. 30 -

MR 6 4.6Supply & Fixing of miscellaneous structural support for horizontal/ verticalexhaust & raw water piping including fabrication, hardwares and painting asper specifications.

kg 1,000 -

WAPCOS Ltd.Signature of Bidder

Ref. No. S.NO. DESCRIPTION UNIT RATE QUANTITY AMOUNT

MR 7 4.9

Supplying, fixing , wiring, testing and commissioning of aviation lightingfixtures, made of cast aluminium fitted with polycarbonate cover with LED orapproved equivalent.

Each 1 -

MR 8 4.12

Supply, fabrication, installation, testing & commissioning of M.S. day oil tankof 990 litres capacity fabricated out of min. 2mm thick M.S. sheet installed onsteel frame or masonry pedestal, suitably treated with anticorrosivetreatment on inside & outside surface with all associated accessories, filters,valves & fittings including level indicator and float switch complete asrequired.

Each 1 -

4.14

Providing, fixing, testing & commissioning of M.S. class `C' (heavy duty) pipesconforming to IS:1239 and fittings like tees, elbows, junctions, unions, bends,plugs, flanges and valves as per P.I.D etc. clamps, structural supports asrequired/ directed at site including jointing of pipes, cutting & making goodthe walls, floors, RCC work etc. cutting chases & filling the same with cementconcrete 1:3:6 (1 cement :3 coarse sand :6 graded stone aggregate 20 mmnominal size) or cement mortar 1:4 (1 cement :4 coarse sand) as requiredincluding painting the pipes with desired shade of enamel paint over a coat ofprimer along with pyp coating over the pipes in roadcrossing area.

MR 9 a 25 mm dia Metre 30 -Subtotal carried over to summary -

5 CHAPTER 5: LT PANELSSupply, of indoor/outdoor floor mounted/ wall mounted, IP43/IP65, factorybuilt, modular, sectionalised, compartmentalized, extendable type LT cubiclepanel of suitable size suitable for operation on 433/415 volts, 50 Hz AC 3phase 4 wire supply system fabricated from CRCA sheet steel of 2mm thickfor frame work and covers, 3mm thick for gland plates with stiffenerswherever required, having vibration free structure chemically treated withseven tank process or better before painting for surface treatment andpowder coated in approved shade, with suitable electrolytic grade highconductivity bus bars extensible, DMC/ SMC (whichever is superior) bus barsupports, with short circuit withstand capacity as mentioned ,bottom basechannel of section not less than 100mmX 50mmX 5 mm thick, fabricationshall be done in transportable sections, entire panel shall have a commonearth bar of required size at the rear with 2 Nos. earth stud, connections andinterconnection with solid conductor wires / copper strips, neutral links,control wiring with 1.5 sqmm. & 2.5sqmm. PVC insulated FRLS copperconductor S/C cable for voltage & current respectively, including providingand fixing following switch gears and as per schedules ,technicalspecifications etc.complete as required.

aThe Switchboards shall have provision to accommodate all cables from thebottom /top as required.

b

All live accessible parts shall be shrouded with 1mm thick polycarbonate/3mm thick FRP sheet and all equipment shall be finger touch proof. The busbarinsulation shall be with heat shrinkable sleeves according to the colour code.SMC shrouds and busbar supports shall be used. All MCCB door handle shallbe interlocked and lockable in OFF position.

cGalvanised hardware with zinc passivation shall be used in fabrication ofSwitchboards.

dSuitable Aluminium earth bus to be provided throughout the length ofSwitchboards.

e All indication lamps / illuminated push buttons shall be LED type.f 2A SP MCBs shall be used as backup protections.g All MCCBs shall be provided at least with ON, OFF & Trip indication lamps.

hAll MCCBs shall be with thermal magnetic releases up to 250 A rating andwith microprocessor based releases above 250 A rating, line load reversibility,Ics = 100% Icu,& extended rotary handle unless otherwise specified

i All MCCB shall have rotary handle with pad locking arrangement.WAPCOS Ltd.Signature of Bidder

Ref. No. S.NO. DESCRIPTION UNIT RATE QUANTITY AMOUNT

j

All micrprocessor based MCCBs shall have inbuilt earth fault protection withvariable earth fault settings & last fault trip history and all thermal magneticbased MCCBs shall be provided earth fault protection through E/F modulewith fault differentiation.

k Door interlocking for all outgoing feeders shall be provided.l All TP MCCB'S shall have solid neutral link,disconnect type.

mAll control & power wiring shall be broughtout upto the cable alley in theterminal blocks.

nAll ACBs shall be with micropocessor based releases (O/C, S/C, E/F &Instantaneous). All ACBs shall have ZSI protection & trip history.

oAll outgoing terminals shall be provided in cable alley on proper insulatedsupports (SMC/DMC).

pAll rear door of Main Isolation Panel shall be almirah type with lockablearrangement.

qSpace heater shall be provided with thermostat with 6A MCB as backupprotection inside all cable alleys controlled with feeder 20 A DP MCB 10 KA.

r An approval shall be taken for each panel before manufacturing.

sProvision of one 6/16 amp socket & compartment lighting for each verticalsection of panel.

t5 nos extra of each R,Y,B,G,A colour indicating lamp and illuminated pushbuttons and normal push button shall be provided with all panels.

u MIMIC diagram shall be provided for Main Isolation panel

v

MIMIC shall be made of polycarbonate sheet of 5 mm thickness fixed onacylic sheet of 2mm thick.the size of panel shall be such that the diagram canbe visualized from 5 to 6 meter distance. The panel shall display completesingle line diagram of Main LT Panel. this line diagram shall be made fromluminous non fading materials to glow in dark and each breaker legend shallbe provided with bi-colour LED lights to show the ON/OFF status of therespective feeder (Incomers / Bus couplers)

w Illuminated push button on Starter Panels of Pumps.x Interlocking / Auto start command terminals for starter Panels.y All breaking Capacity for ACB to be Ics=100%Icu and Icw for 1 sec..

zAll breaking Capacity for MCCB to be Ics=100%Icu and Uimp of 8KV & shall besingle frame till 250A to save the inventory

aaAll ACB's shall have all standard accessories such as CT's Arc chute,safetyshutter,etc.

abLinks and drops from ACB/MCCB shall be designed for full rated current ofACB/MCCB rating at same amount of current density as of main busbar.

ac All MCB to be C Curve for raw power and D curve for UPS power.ad Removable lifting hook shall be provided in all transportation section.ae Each Section of the Main isolation to be provided with Ventilation Fans.

afMultifunction meters installed shall be BMS Compatible, capable of deliveringBacnet, Modbus or Lonworks protocol etc.

agBus bar shall be high conductivity (99%), ETP - Electrical grade copper or 50-55% Aluminium as specified in BOQ.

ahBus bar shall be designed on 45 deg. Ambient temperature and limit oftemperature rise shall be 35 deg. Over and above Ambient temperature.

ai Bus bars shall be with heat shrinkable PVC sleeves.aj MCB's shall be of minimum 10kA fault with stand capacity.

akConcerning vendor needs to furnish the busbar calculations (for both phaseand earth bus) at the time of GA approval and busbar size has to be as perthe approved GA drawing.

MR 10 5.1 Main Isolation Panel - Substation Set 1 -

WAPCOS Ltd.Signature of Bidder

Ref. No. S.NO. DESCRIPTION UNIT RATE QUANTITY AMOUNTIncoming from grid:1 x 630 A, FP, 50 kA, Electrically draw out type ACB with On, Off, Trip, SpringCharge indication and with inbuilt LSIG protection with microprocessor basedrelease, shunt release (24V DC), inbuilt O/C & SC releases (Microprocessorbased) having variable range with time lag facility to acheive discrimination.And required Interlocking between other incomer & Bus Coupler to beprovided as per Interlocking / operation scheme indicated in Single Linediagram. The ACB shall have suitable arrangement for termination of busducton incoming side and busbar connection at outgoing side as per single linediagram, complete with following for each incomer:1 x 50kA, 2kVp surge arrester with suitable Fuse.1 x R,Y,B,On,Off,Trip,Spring charge, Service position, test position, ready toclose, trip circuit healthy LED indication lamp with 2A control MCB etc. asrequired.1 x (16 window annunciation panel with trip, accept & reset options alongwith hooter)1 x (Restricted earth fault relay each with 4 nos. CL-PS, 15VA, ring type CT ofrequired ratio)1 x (emergency Push buttons, auto/manual switch, etc. as required)1 x (3 nos. 630/1A, CL-1, 15VA, ring type CT for 240V actuated numeric typeAPFC relay)1 x (emergency Push buttons, auto/manual switch, etc. as required)1 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485communication port for measurement of at least THD, KVARH KW, KWH,KVAR, PF, V, A, Hz with 15VA Class 1.0 CTs of required ratio)Incoming from solar:1 x 63 A, FP, 16 kA, MCCB with On, Off, Trip and with inbuilt LSIG protectionwith microprocessor based release, shunt release (24V DC), inbuilt O/C & SCreleases (Microprocessor based) having variable range with time lag facility toacheive discrimination. And required Interlocking between other incomer &Bus Coupler to be provided as per Interlocking / operation scheme indicatedin Single Line diagram. The ACB shall have suitable arrangement fortermination of busduct on incoming side and busbar connection at outgoingside as per single line diagram, complete with following for each incomer:

1 x 50kA, 2kVp surge arrester with suitable Fuse.1 x R,Y,B,On,Off,Trip,Spring charge, Service position, test position, ready toclose, trip circuit healthy LED indication lamp with 2A control MCB etc. asrequired.1 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485communication port for measurement of at least THD, KVARH KW, KWH,KVAR, PF, V, A, Hz with 15VA Class 1.0 CTs of required ratio)Busbar (1 Set - 4P + E)Busbar made up of electrolytic grade high conductivity aluminium inrectangular cross section and suitable for 415V, FP, 50 Hz, 800 A, 25 kA for 1sec of required length and cross sectional area.

Buscoupler :1 x 630 A, FP, 50 kA, Electrically draw out type ACB with On, Off, Trip, SpringCharge indication and with inbuilt LSIG protection with microprocessor basedrelease. Required Interlocking between other incomer & Bus Coupler to beprovided as per Interlocking / operation scheme indicated in Single Linediagram.

WAPCOS Ltd.Signature of Bidder

Ref. No. S.NO. DESCRIPTION UNIT RATE QUANTITY AMOUNTIncoming from 200KVA DG Set - 1 nos.:1 x 630 A, FP, 50 kA, Electrically draw out type ACB with On, Off, Trip, SpringCharge indication and with inbuilt LSIG protection with microprocessor basedrelease, shunt release (24V DC), inbuilt O/C & SC releases (Microprocessorbased) having variable range with time lag facility to acheive discrimination.And required Interlocking between other incomer & Bus Coupler to beprovided as per Interlocking / operation scheme indicated in Single Linediagram. The ACB shall have suitable arrangement for termination of cable onincoming side and busbar connection at outgoing side as per single linediagram, complete with following for incomer:

1 x 50kA, 2kVp surge arrester with suitable Fuse.1 x R,Y,B,On,Off,Trip,Spring charge, Service position, test position, ready toclose, LED indication lamp with 2A control MCB etc. as required.1 x (16 window annunciation panel with trip, accept & reset options alongwith hooter)1 x (Auxiliary contactor 6 No + 6 NC, suitable for 24 V DC.)

1 x (start/stop, trip/reset, spring charge, emergency Push buttons,auto/manual switch, test, service, trip circuit healthy, DC healthy indicationsetc. as required)1 x (230 V, Single Phase, 50 HZ, AC operated Battery Charger for DG Batterycharging only, with Boost and trickle charging facility and protection fromover charging the battery with voltmeter of range 0-50 Volts and Ammeter ofrange 0-50 Amp)1 x (15VA, Class 1.0 CTs of required ratio including wiring for MFM)1 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485communication port for measurement of at least THD, KVARH KW, KWH,KVAR, PF, V, A, Hz with 15VA Class 1.0 CTs of required ratio)1 x (IDMT based relay module with Ac inverse time overcurrent,instantaneous overcurrent relay, instantaneous earth fault relay,Overvoltage, undervoltage with dead band bypass feature, frequency, phasesequence, reverse power and earth fault relay along with 1000/1A, CL-5P10,15VA, CT)1 x (Restricted earth fault relay with required CTs)Micro PLC for Auto Load Management as per Logic mentioned in Single LineDiagram, comprising required Auxiliary relays (24V DC, indication lights, Pushbutton, Emergency stop, A/M position switch, Battery charger (230V A/C /24V DC), Batteries, Digital I/O card, analogue card, 24V DC power supply asrequired.The AMF operation of DG Sets shall be carried out by controller installed oneach DG Set by DG Manufacturer however required coordination andprovisions to achieve the same in coordination with PLC based Auto LoadManagement is included in the scope of work of Panel Manufacturer.Outgoings :1 x 250 A, FP, 25kA, MCCB with On, Off, Trip indication and o/l, s/c & e/fprotection with micoprocessor based release..1 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485communication port for measurement of at least KWH, KVAR, PF, V, A, Hzwith 10VA Class 1.0 CTs of required ratio)1 x 200 A, FP, 25kA, MCCB with On, Off, Trip indication and o/l, s/c & e/fprotection with micoprocessor based release..1 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485communication port for measurement of at least KWH, KVAR, PF, V, A, Hzwith 10VA Class 1.0 CTs of required ratio)2 x 100 A, FP, 25kA, MCCB with On, Off, Trip indication and o/l, s/c & e/fprotection with micoprocessor based release..2 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485communication port for measurement of at least KWH, KVAR, PF, V, A, Hzwith 10VA Class 1.0 CTs of required ratio)

WAPCOS Ltd.Signature of Bidder

Ref. No. S.NO. DESCRIPTION UNIT RATE QUANTITY AMOUNT2 x 63 A, FP, 25kA, MCCB with On, Off, Trip indication and o/l, s/c & e/fprotection with micoprocessor based release..2 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485communication port for measurement of at least KWH, KVAR, PF, V, A, Hzwith 10VA Class 1.0 CTs of required ratio)

MR 11 5.2 Capacitor panel - Substation Set 1 -Incomer :R,Y,B LED indication lamp with 2A control MCB.1 x 250 A, FP, 25 kA, MCCB with On, Off, Trip,R,Y,B indication and with inbuiltLSIG protection with microprocessor based release.1 x (Digital flush type class -1.0 accuracy multifunction meter with RS-485communication port for measurement of KWH, KVAR, PF, V, A, Hz with 10VAClass 1.0 CTs of required ratio)1 x 12 numeric type stepped relay (APFCR) with 12 steps (each to be of10/15/25/50/100 KVAR as required) for automatic power factor correctionhaving facility to change the sequence of switching 'ON' the capacitor banksas required. The program of APFCR shall be re settable to enable sequance ofON/OFF of individual bank, so that the end unit of capacitor bank is not keptidle for long.Busbar (1 Set - 4P + E)Busbar made up of electrolytic grade high conductivity aluminium inrectangular cross section and suitable for 415V, FP, 50 Hz, 600 A, 25 kA for 1sec of required length and cross sectional area.

Outgoings :1 x (32 Amp, 25kA, TP, MCCB (TM Based) + capacity ducty contact + 7%detuned reactor + 15kVAr MPPH type heavy duy capacitor)1 x (25 Amp, 25kA, TP, MCCB (TM Based) + capacity ducty contact + 7%detuned reactor + 10kVAr MPPH type heavy duy capacitor)(rated at 480V with min 13.33 kVAr @ 480V)4 x (16 Amp, 25kA, TP, MCCB (TM Based) + capacity ducty contact + 7%detuned reactor + 5kVAr MPPH type heavy duy capacitor)(rated at 480V with min 6.53 kVAr @ 480V)1 x (16 Amp, 25kA, TP, MCCB (TM Based) + capacity ducty contact + 7%detuned reactor + 3kVAr MPPH type heavy duy capacitor)(rated at 480V with min 3.9 kVAr @ 480V)1 x (16 Amp, 25kA, TP, MCCB (TM Based) + capacity ducty contact + 7%detuned reactor + 2kVAr MPPH type heavy duy capacitor)(rated at 480V with min 2.6 kVAr @ 480V)4 x Spare

MR 12 5.3 Main Distribution Board - Indoor Hall Set 1 -Incomer :R,Y,B LED indication lamp with 2A control MCB.1 x 200 A, FP, 16kA, MCCB with trip settings as required.1 x (Digital flush type class -1.0 accuracy multifunction meter with RS-485communication port for measurement of KWH, KVAR, PF, V, A, Hz with 5VAClass 1.0 CTs of required ratio)

Busbar (1 Set - 4P + E)Busbar made up of electrolytic grade high conductivity aluminium inrectangular cross section and suitable for 415V, FP, 50 Hz, 300 A, 10 kA for 1sec of required length and cross sectional area.

Outgoings :6 x 63 A, FP, 10kA, MCB.6 x 40 A, FP, 10kA, MCB.

MR 13 5.4 HVAC Panel - Terrace (outdoor type) Set 1 -

WAPCOS Ltd.Signature of Bidder

Ref. No. S.NO. DESCRIPTION UNIT RATE QUANTITY AMOUNTIncomer :R,Y,B LED indication lamp with 2A control MCB.1 x 250 A, FP, 16kA, MCCB with trip settings as required.1 x (Digital flush type class -1.0 accuracy multifunction meter with RS-485communication port for measurement of KWH, KVAR, PF, V, A, Hz with 5VAClass 1.0 CTs of required ratio)

Busbar (1 Set - 4P + E)Busbar made up of electrolytic grade high conductivity aluminium inrectangular cross section and suitable for 415V, FP, 50 Hz, 400 A, 10 kA for 1sec of required length and cross sectional area.

Outgoings :10 x 40 A, FP, 10kA, RCBO2 x 40 A, FP, 10kA, MCB4 x 7.5kW star delta starter, 16A TP 50kA, MPCB with OLR range 6.3-10A SPP,32A delta contactor and 9A star contactor with (0-40A) ameter & ameterselector switch with CL-3, 5VA, CTs of required ratio.4 x 5.5kW star delta starter, 16A TP 50kA, MPCB with OLR range 5-8A SPP,32A delta contactor and 9A star contactor with (0-40A) ameter & ameterselector switch with CL-3, 5VA, CTs of required ratio.

MR 14 5.5

Feeder Pillar:Design, Supply, Installation, Testing , internal wiring and Commissioning offollowing Feeder pillars suitable for outdoor application IP55 made up ofCRCA sheet 1.6mm thickness with following accessories :Supplying, installation, testing and commissioning of Photo sensor/Lux sensorand timer with Astronomical time switch of following configuration to bemounted in feeder pillars for automatic switching On & OFF of external lightsat sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with timerfacility with 12/24 hour display format with suitable battery and indication forrelay status i/c programming at site complete as required.

Set 1 -

Incomer:1 x R,Y,B LED indication lamp with 2A control MCB1 x 100 A, FP, 16kA, MCCB with On, Off, Trip indication and o/l, s/c & e/fprotection with thermal magnetic based release.1 X (Digital flush type class -1.0 accuracy multifunction meter with RS-485communication port for measurement of KVAR, PF, KWH, V, A with3X100/5A, 5VA Class 1.0 CTs)Busbar (1 Set - 4P + E)Busbar made up of electrolytic grade high conductivity aluminium inrectangular cross section and suitable for 415V, FP, 50 Hz, 150 A, 10 kA for 1sec of required length and cross sectional area.Note : Concerning vendor needs to furnish the busbar calculations (for bothphase and earth bus) at the time of GA approval and busbar size has to be asper the approved GA drawing.Outgoings :4 Nos. x 40A, FP, RCB0, 10kA4 Nos. x 32A, FP, RCB0, 10kA2 Nos. x 25A, FP, RCB0, 10kA4 Nos. x 40A, FP, MCB, 10kA C Curve.Subtotal carried over to summary -

6 CHAPTER 6 : UPS

WAPCOS Ltd.Signature of Bidder

Ref. No. S.NO. DESCRIPTION UNIT RATE QUANTITY AMOUNT

MR 15 6.1

Supply, of On Line double conversion fully microprocessor based Compact 5KVA UPS System with IGBT based PWM Technology to achieve THD < 3% andinput power factor of greater than 0.95 at 50% loading.suitable for singlephase AC input voltage 220 V to 260 V, 50 Hz +10% / - 10 % and single phaseAC output voltage 230 ± 1% Volts & frequency 50 ± 0.5 Hz , input isolationtransformer which shall be housed in rugged enclosure made of MS sheet 1.2mm thick aesthetically finished, duly pre-treated and powder coated having30 minutes back up time at full load including necessary SMF battery &mounting Rack and suitable size connecting cable (for UPS to Battery andbattery to battery), static and Maintenance bypass switch, SNMP card forRS232/ RS485 computability for operation and monitoring etc. complete asrequired and as per CPWD specifications.

Set 1 -

Subtotal carried over to summary -7 CHAPTER 7: LT CABLES & TERMINATIONS

7.1

Supplying following 1.1kV grade, XLPE insulated, FRLS typearmoured/unarmoured cables suitable for 415V, 50Hz, AC system, with innerand outer PVC sheath, outer sheath provided with FRLS insulation and withall components as mentioned in BOQ, specifications and schedule, completeas required.

MR 16 7.1.3 3.5C X 185 Sqmm A2XFY. Metre 165 -MR 17 7.1.4 3.5C X 150 Sqmm A2XFY. Metre 154 -MR 18 7.1.7 3.5C X 95 Sqmm A2XFY. Metre 132 -MR 19 7.1.7 3.5C X 70 Sqmm A2XFY. Metre 44 -MR 20 7.1.9 4C X 35 Sqmm A2XFY. Metre 77 -MR 21 7.1.11 4C X 16 Sqmm 2XWY. Metre 462 -MR 22 7.1.13 4C X 10 Sqmm 2XWY. Metre 330 -MR 23 7.1.14 4C X 6 Sqmm 2XWY. Metre 198 -MR 24 7.1.28 2C X 6 sqmm 2XWY Metre 100 -MR 25 7.1.27 1C X 10 sqmm 2XY Metre 100 -MR 26 7.1.22 4C X 6 Sqmm A2XFY. Metre 800 -

7.2

Supplying following 1.1kV grade, XLPE insulated, FRLS type controlcables,suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath,outer sheath provided with FRLS insulation and with all components asmentioned in BOQ, specifications and schedule, complete as required.

MR 27 7.2.1 2C X 2.5 sqmm copper conductor Metre 50 -MR 28 7.2.2 4C X 2.5 sqmm copper conductor Metre 50 -MR 29 7.2.3 6C X 2.5 sqmm copper conductor Metre 50 -MR 30 7.2.4 10C X 2.5 sqmm copper conductor Metre 20 -MR 31 7.2.5 21C X 2.5 sqmm copper conductor Metre 20 -

7.3Laying of one number PVC insulated and PVC sheathed/XLPE power cable of1.1kV grade of following size in the existing RCC trench / Hume pipe / pipecomplete as required.

7.5.1 7.3.1 Up to 35 sqmm Metre -7.5.2 7.3.2 Above 35 sqmm and up to 95 sqmm Metre -7.5.3 7.3.3 Above 95 sqmm and up to 185 sqmm Metre 223 -7.5.4 7.3.4 Above 185 sqmm and up to 400 sqmm Metre -

7.8 7.4Laying and fixing of one number PVC insulated and PVC sheathed / XLPEpower cable of 1.1 KV grade of following size on cable tray as required.

7.8.1 7.4.1 Upto 35 sq. mm (clamped with 1mm thick saddle) Metre 1,457 -

7.8.2 7.4.2 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) Metre 176 -

7.8.3 7.4.3Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flatclamp)

Metre 135 -

7.8.4 7.4.4Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flatclamp)

Metre -

9.1 7.5Supplying and making end termination with brass compression gland andaluminium lugs for following size of PVC insulated and PVC sheathed / XLPEaluminium conductor cable of 1.1 kV grade as required.

9.1.30 7.5.1 3½ X 300 sq. mm (70 mm) Each -WAPCOS Ltd.Signature of Bidder

Ref. No. S.NO. DESCRIPTION UNIT RATE QUANTITY AMOUNT9.1.29 7.5.2 3½ X 240 sq. mm (62 mm) Each -9.1.27 7.5.2 3½ X 185 sq. mm (57 mm) Each 2 -9.1.26 7.5.3 3½ X 150 sq. mm (50 mm) Each 8 -9.1.25 7.5.4 3½ X 120 sq. mm (45 mm) Each -9.1.24 7.5.4 3½ X 95 sq. mm (45 mm) Each 2 -9.1.23 7.5.5 3½ X 70 sq. mm (38mm) Each 2 -9.1.22 7.5.6 3½ X 50 sq. mm (35 mm) Each -9.1.35 7.5.7 4 X 35 sq. mm (32 mm) Each 4 -9.1.34 7.5.8 4 X 25 sq. mm (28 mm) Each -9.1.33 7.5.9 4C X 16 Sqmm (28mm) Each -9.1.32 7.5.10 4C X 10 Sqmm (25mm) Each -9.1.32 7.5.10 4C X 6 Sqmm (25mm) Each 40 -

7.7Supplying and making end termination with brass compression gland andcopper lugs for following size of PVC insulated and PVC sheathed / XLPEcopper conductor cable of 1.1 kV grade as required.

9.1.33 7.7.1 4C X 16 Sqmm (28mm) Each 22 -9.1.32 7.7.2 4C X 10 Sqmm (25mm) Each 14 -9.1.1 7.7.12 2C X 6 sqmm (19mm) Each 10 -

MR 32 7.7.15 4C X 6 Sqmm 2XWY. Each 8 -MR 33 7.7.22 1C X 10 sqmm 2XY Each 4 -MR 34 7.7.23 2C X 2.5 sqmm copper conductor Each 2 -MR 35 7.7.24 4C X 2.5 sqmm copper conductor Each 2 -MR 36 7.7.25 6C X 2.5 sqmm copper conductor Each 2 -MR 37 7.7.26 10C X 2.5 sqmm copper conductor Each 2 -MR 38 7.7.27 21C X 2.5 sqmm copper conductor Each 2 -

Subtotal carried over to summary -8 CHAPTER 8: CABLES MANAGEMENT

4.1 8.1

Supplying and installing following size of perforated painted with powdercoating M.S. cable trays with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceilingwith M.S. suspenders including bolts & nuts, painting suspenders etc. asrequired.

4.1.1 8.1.1 100 mm width x 50 mm depth x 1.6 mm thickness Metre 30 -4.1.3 8.1.2 200 mm width x 50 mm depth x 1.6 mm thickness Metre - -4.1.4 8.1.3 300 mm width x 50 mm depth x 1.6 mm thickness Metre 50 -4.1.6 8.1.4 450 mm width x 50 mm depth x 2 mm thickness Metre 50 -

4.1.16 8.1.5 900 mm width x 75 mm depth x 2 mm thickness Metre 20 -

8.2

Supplying and installing following size of perforated painted with powdercoating M.S. cable trays "bends" with perforation not more than 17.5%,,joined with connectors, suspended from the ceiling with M.S. suspendersincluding bolts & nuts, painting suspenders etc. as required.

4.2.1 8.2.1 100 mm width X 50 mm depth X 1.6 mm thickness Each 5 -4.2.3 8.2.3 200 mm width X 50 mm depth X 1.6 mm thickness Each - -4.2.4 8.2.4 300 mm width X 50 mm depth X 1.6 mm thickness Each 8 -4.2.6 8.2.5 450 mm width x 50 mm depth x 2 mm thickness Each 8 -

4.2.16 8.2.9 900 mm width x 75 mm depth x 2 mm thickness Each 3 -

8.3

Supplying and installing following size of perforated painted with powdercoating M.S. cable trays "Tee" with perforation not more than 17.5%, joinedwith connectors, suspended from the ceiling with M.S. suspenders includingbolts & nuts, painting suspenders etc. as required.

4.3.1 8.3.1 100 mm width X 50 mm depth X 1.6 mm thickness Each 1 -4.3.3 8.3.2 200 mm width X 50 mm depth X 1.6 mm thickness Each 1 -4.3.4 8.3.3 300 mm width X 50 mm depth X 1.6 mm thickness Each 1 -4.3.6 8.3.4 450 mm width x 50 mm depth x 2 mm thickness Each 1 -

4.3.16 8.3.5 900 mm width x 75 mm depth x 2 mm thickness Each 1 -

WAPCOS Ltd.Signature of Bidder

Ref. No. S.NO. DESCRIPTION UNIT RATE QUANTITY AMOUNT

8.4

Supplying and installing following size of perforated painted with powdercoating M.S. cable trays "Cross Member" with perforation not more than17.5%, joined with connectors, suspended from the ceiling with M.S.suspenders including bolts & nuts, painting suspenders etc. as required.

4.4.1 8.4.1 100 mm width X 50 mm depth X 1.6 mm thickness Each 1 -4.4.3 8.4.2 200 mm width X 50 mm depth X 1.6 mm thickness Each - -4.4.4 8.4.3 300 mm width X 50 mm depth X 1.6 mm thickness Each 1 -4.4.6 8.4.4 450 mm width x 50 mm depth x 2 mm thickness Each 1 -

4.4.16 8.4.5 900 mm width x 75 mm depth x 2 mm thickness Each 1 -

8.5

Supplying and installing following size of perforated painted with powdercoating M.S. cable trays Reducer with perforation not more than 17.5%,joined with connectors, suspended from the ceiling with M.S. suspendersincluding bolts & nuts, painting suspenders etc as required.

4.5.4 8.5.4 300 mm width X 50 mm depth X 1.6 mm thickness Each 1 -4.5.6 8.5.5 450 mm width x 50 mm depth x 2 mm thickness Each 1 -

4.5.16 8.5.9 900 mm width x 75 mm depth x 2 mm thickness Each 2 -Subtotal carried over to summary -

9 CHAPTER 9: DISTRIBUTION BOARD

OSR 20182.3

9.1

Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 V, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)

2.3.6 9.1.2 8 way, Double door Each -2.3.7 9.1.3 12 way, Double door Each 2 -

OSR 20182.5

9.2

Supply and fixing of following way three pole and neutral, sheet steel, MCBdistribution, 415 V on surface / recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCBknobs detachable gland plate, interconnections, phosphatized and powderpainted including earthing etc. as required ( But with out MCB/ RCCB/Isolator)

2.5.5 9.2.1 4 way (4 + 12), Double door Horizontal Type Each - -2.5.6 9.2.2 6 way (4 + 18), Double door Horizontal Type Each 3 -2.5.7 9.2.3 8 way (4 + 24), Double door Horizontal Type Each 3 -

2.5 9.3

Supplying and fixing of following ways surface/ recess mounting,vertical type,415 V, TPN MCB distribution board of sheet steel, dust protected, dulypowder painted, inclusive of 200 A, tinned copper bus bar, common neutrallink, earth bar, din bar for mounting MCBs (but without MCBs and incomer)as required. (Note : Vertical type MCB TPDB is normally used where 3 phaseoutlets are required.)

2.5.1 9.3.1 4 way Double door (8 + 12) Each - -2.5.2 9.3.1 8 way Double door (8 + 24) Each -2.5.3 9.3.2 12 way Double door (8 + 36) Each 1 -

2.24 9.5

Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable forfollowing triple pole and neutral, sheet steel, MCB distribution board, 415 V,on surface/ recess, complete with testing and commissioning etc. as required.

2.24.3 9.5.1 For 8 way, Double door TPN MCBDB Each 1 -

2.25 9.6Supplying and fixing Cable End Box (Loose wire box) suitable for triple poleand neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/recess, complete with testing and commissioning etc. as required.

Each 1 -

OSR 2.7 9.7

Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve,miniature circuit breaker suitable for inductive load of following poles in theexisting MCB DB complete with connections, testing and commissioning etc.as required.

2.7.1 9.7.1 Single pole Each 24 -

WAPCOS Ltd.Signature of Bidder

Ref. No. S.NO. DESCRIPTION UNIT RATE QUANTITY AMOUNT

9.8

Supplying and fixing 40 amps rating, 240/415 volts, "C" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existingMCB DB complete with connections, testing and commissioning etc. asrequired.

MR 39 9.8.1 Double pole Each 5 -MR 40 9.8.3 Triple pole Each 2 -MR 41 9.8.3 Four pole Each 6 -

9.9

Supplying and fixing 63 amps rating, 240/415 volts, "C" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existingMCB DB complete with connections, testing and commissioning etc. asrequired.

MR 42 9.9.2 Triple pole Each 2 -MR 43 9.9.2 Four pole Each 6 -

9.9

Supplying and fixing 100 amps rating, 240/415 volts, "C" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existingMCB DB complete with connections, testing and commissioning etc. asrequired.

MR 44 9.9.2 Four pole Each 1 -

OSR 20182.10

9.12

Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB) having sensitivity up to30milliampere in the existing MCB DB complete with connections, testingcommissioning etc. as required.

2.10.2 9.12.2 40 amps Each 5 -

2.11 9.13Supplying and fixing single pole blanking plate in the existing MCB DBcomplete etc. as required.

Each 20 -

2.19 9.17

Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, TPMCB, insheet steel enclosure, on surface or in recess, with chained metal cover forthe socket out let and complete with connections, testing and commissioningetc. as required.

Each 2 -

2.18 9.18

Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB,in sheet steel enclosure, on surface or in recess, with chained metal cover forthe socket out let and complete with connections, testing and commissioningetc. as required.

Each 2 -

Subtotal carried over to summary -10 CHAPTER 10: WIRING

1.10 1.1

Wiring in PVC Conduit:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, with modular switch, modular plate,suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required

1.10.3 1.1.1 Group C Point 50 -

1.14 1.2Wiring for circuit/ submain wiring alongwith earth wire with the followingsizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.

1.14.1 1.2.1 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire. Metre 207 -1.14.2 1.2.2 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire. Metre 691 -1.14.3 1.2.3 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire Metre 1,152 -1.14.4 1.2.4 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire Metre 60 -1.14.8 1.2.5 4 x 4 sq.mm. + 2 x 4 sq.mm. earth wire. Metre 184 -1.14.9 1.2.6 4 x 6 sq.mm. + 2 x 6 sq.mm. earth wire Metre 461 -

1.14.10 1.2.7 4 x 10 sq.mm. + 2 x 6 sq.mm. earth wire Metre 12 -

WAPCOS Ltd.Signature of Bidder

Ref. No. S.NO. DESCRIPTION UNIT RATE QUANTITY AMOUNT

1.3 1.3

Wiring in Steel Conduit:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed steel conduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable etc. as required

1.3.3 1.3.1 Group C Point 300 -

1.7 1.4Wiring for circuit/ submain wiring alongwith earth wire with the followingsizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed steel conduit as required.

1.7.1 1.4.1 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire. Metre 65 -1.7.2 1.4.2 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire. Metre 216 -1.7.3 1.4.3 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire Metre 360 -1.7.4 1.4.4 2 x 6 sq.mm. + 1 x 6 sq.mm. earth wire Metre 15 -1.7.8 1.4.5 4 x 4 sq.mm. + 2 x 4 sq.mm. earth wire. Metre 58 -1.7.9 1.4.6 4 x 6 sq.mm. + 2 x 6 sq.mm. earth wire Metre 144 -

1.7.10 1.4.7 4 x 10 sq.mm. + 2 x 6 sq.mm. earth wire Metre 3 -

1.25 1.5Supplying and fixing two module stepped type electronic fan regulator on theexisting modular plate switch box including connections but excludingmodular plate etc. as required.

Each 20 -

1.26 1.6Supplying and fixing modular blanking plate on the existing modular plate &switch box excluding modular plate as required.

Each 100 -

1.34 1.7Supplying and fixing of brass batten / angle holder / connectors includingconnections etc. as required.

Each 20 -

1.38 1.8Supplying and fixing call bell/ buzzer suitable for single phase, 230 V,complete as required.

Each - -

1.50 1.9Installation of exhaust fan in the existing opening , including making good thedamage, connection, testing commissioning etc. as required.

1.50.1 1.9.1 (a): Up to 450mm sweep Each 5 -

1.51 1.10Extra for fixing the louvers / shutters complete with frame for a exhaust fanof all sizes.

Each 5 -

1.57 1.11

Supplying & fixing suitable size GI box wih modular plate and cover in fronton surface or in recess including providing and fixing 25 A modular socketoutlet and 25 A modular SP MCB, “C” curve including connections, paintingetc. as required.

Each 5 -

1.43 1.13

Providing and fixing extra conduit down rod of 20 mm dia, 2 X 10 cm length,wiring with 2 X 1.5 sq. mm FRLS PVC insulated, copper conductor, single corecable including painting etc. as required.(Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5cm or less shall be ignored)Remark: The item shall be executed for the suspended light points.

Each 20 -

1.45 1.14

Installation, testing and commissioning of ceiling fan,including wiring thedown rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVCinsulated, copper conductor, single core cable, including providing and fixingphenolic laminated sheet cover on the fan box etc. as required.

Each 20 -

1.20 1.15Supplying and fixing of following sizes of steel conduit along with accessoriesin surface/recess including painting in case of surface conduit, or cutting thewall and making good the same in case of recessed conduit as required.

1.20.2 1.15.1 25 mm Metre 800 -1.20.3 1.15.2 32 mm Metre 80 -1.20.4 1.15.3 40 mm Metre 20 -1.20.5 1.15.4 50 mm Metre 20 -

1.21 1.16Supplying and fixing of following sizes of medium class PVC conduit alongwith accessories in surface/recess including cutting the wall and making goodthe same in case of recessed conduit as required.

1.21.2 1.16.1 25 mm Metre 100 -1.21.3 1.16.2 32 mm Metre 10 -1.21.4 1.16.3 40 mm Metre 10 -1.21.5 1.16.4 50 mm Metre 10 -

WAPCOS Ltd.Signature of Bidder

Ref. No. S.NO. DESCRIPTION UNIT RATE QUANTITY AMOUNT

Civil DSR10.17

1.17

Providing and fixing M.S. Fan clamp type I or II of 16 mm dia M.S. bar, bent toshape with hooked ends in R.C.C. slabs or beams during laying, includingpainting the exposed portion of loop, all as per standard design complete asrequired.

Each 20 -

Civil DSR10.18

1.18

Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceilingfan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S.sheet with its top surface hacked for proper bonding, top lid shall be screwedinto the cast iron/ M.S. sheet box by means of 3.3 mm dia round headedscrews, one lock at the corners. Clamp shall be made of 12 mm dia M.S. barbent to shape as per standard drawing.

Each 20 -

1.28 1.19Supplying and fixing following Modular base & cover plate on existingmodular metal boxes etc. as required.

1.28.1 1.19.1 1 or 2 Module Each 40 -1.28.2 1.19.2 3 Module Each 110 -1.28.3 1.19.3 4 Module Each 10 -1.28.4 1.19.4 6 Module Each 20 -1.28.5 1.19.5 8 Module Each 10 -1.28.6 1.19.6 12 Module Each 10 -

1.24 1.20Supplying and fixing following modular switch / socket on existing modularplate and switch box including connections but excluding modular plate etc asrequired.

1.24.1 1.20.1 5/6 amps switch Each 130 -1.24.3 1.20.2 15/16 amp switch Each 70 -1.24.4 1.20.3 3 pin 5/6 amp socket outlet Each 60 -1.24.5 1.20.4 6 pin 15/16 amp socket outlet Each 70 -1.24.6 1.20.5 Telephone socket outlet Each 10 -1.24.7 1.20.6 TV antenna socket outlet Each 5 -1.24.8 1.20.7 Bell Push Each 5 -

Subtotal carried over to summary -11 CHAPTER 11: EARTHING & LIGHTNING PROTECTION

5.2 11.1

Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories,and providing masonry enclosure with cover plate having lockingarrangement and watering pipe etc. with charcoal/coke and salt as required.

Each 6 -

5.4 11.2

Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick includingaccessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 metre long etc. with charcoal/ cokeand salt as required.

Each 8 -

5.6 11.3

Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick includingaccessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 metre long etc. with charcoal/ cokeand salt as required.

Each 2 -

OSR 183.19

11.4Providing and fixing 6 SWG G.I. wire on surface or in recess for loop earthingalong with existing surface / recessed conduit / submain wiring / cable asrequired

Metre 1,000 -

5.15 11.5Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess forconnections etc. as required.

Metre 600 -

5.11 11.6Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe fromearth electrode including connection with G.I. nut, bolt, spring, washerexcavation and re-filling etc. as required.

Metre 20 -

5.10 11.7Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe fromearth electrode including connection with G.I. nut, bolt, spring, washerexcavation and re-filling etc. as required.

Metre 10 -

5.14 11.8Providing and fixing 25 mm X 5 mm copper strip on surface or in recess forconnections etc. as required.

Metre 80 -

6.2 11.9Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mmlong, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I.base plate including holes etc. complete as required.

Each 6 -

WAPCOS Ltd.Signature of Bidder

Ref. No. S.NO. DESCRIPTION UNIT RATE QUANTITY AMOUNT

6.7 11.10Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface ofwall for lightning conductor and external lighting complete as required. (ForHorizontal run)

Each 400 -

6.8 11.11Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface ofwall for lightning conductor complete as required. (For vertical run)

Set. 60 -

6.12 11.12Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125mm long, with 4 Nos. of G.I. bolts, nuts, chuck nuts and spring washers etc.complete as required.

Metre 6 -

Subtotal carried over to summary -12 CHAPTER 12: INTERNAL & EXTERNAL LIGHTING FIXTURES AND FANS

12.1

Supply of following Points inside the building. All the below mentioned pointsshall be wired as per the described scheme and with 1.1kV grade, FRLS typeof Cu. The primary shall mean the first light point connected to switch andsecondary means rest all points looped with the said primary. The said wiresshall have stranded conductors and proper gauge. The rate shall includecomplete Supply, rates including cost of conceled PVC conduit in slab alongwith the cost of electronic drivers, ballasts, capacitors, ignitors, ceiling rose /connectors / angle holders , lugs and all tools and accessories required to asrequired to do the job in all respect in accordance with laid specification orupto the satisfaction of engineer in charge.

MR 45 12.1.1

Supply of 2'x2' 36-40W recess mounting type LED luminaire, IP 20 ,colourtemperature 5700K having efficacy not less than 100 lm/W CRCA housing,suitable diffuser, inbuilt electronic driver, including 3 core 1.5 sq.mm FRLSPVC insulated and PVC sheathed copper conductor cable and earthing etc.upto suitable point complete as required.Fixture similar to WIPRO CAT : CRCO10R038HP57GL1 or equivalent

Each 20 -

MR 46 12.1.2

Supply of 2'x2' 36-40W surface mounting type LED luminaire, IP 20 ,colourtemperature 5700K having efficacy not less than 100 lm/W CRCA housing,suitable diffuser, inbuilt electronic driver, including 3 core 1.5 sq.mm FRLSPVC insulated and PVC sheathed copper conductor cable and earthing etc.upto suitable point complete as required.Fixture similar to WIPRO CAT : LE10-491-XXX-57-XX or Equivalent

Each - -

MR 47 12.1.3

Supply of 18W-20W surface mounting type circular downlighter LEDluminaire, IP 20 ,colour temperature 6000K having efficacy not less than 85lm/W, THD ≤ 20%, die cast aluminium/polycarbonate housing, suitablediffuser, inbuilt electronic driver, including 3 core 1.5 sq.mm FRLS PVCinsulated and PVC sheathed copper conductor cable and earthing etc. uptosuitable point complete as required.Fixture Similar to Wipro Cat No.: LD80-171-XXX-60-SM or Equivalent

Each 30 -

MR 48 12.1.4

Supply of 10W-12W recess mounting type LED luminaire, IP 20 ,colourtemperature 6000K having efficacy not less than 80 lm/W, THD ≤ 20%, diecast aluminium/polycarbonate housing housing, suitable diffuser, inbuiltelectronic driver, including 3 core 1.5 sq.mm FRLS PVC insulated and PVCsheathed copper conductor cable and earthing etc. upto suitable pointcomplete as required.Fixture Similar to Wipro Cat No.: LD80-101-XXX-60-XX or Equivalent

Each 25 -

MR 49 12.1.5

Supply of 18W-20W recess mounting type circular downlighter LEDluminaire, IP 20 ,colour temperature 6000K having efficacy not less than 85lm/W, THD ≤ 20%, die cast aluminium/polycarbonate housing, suitablediffuser, inbuilt electronic driver, including 3 core 1.5 sq.mm FRLS PVCinsulated and PVC sheathed copper conductor cable and earthing etc. uptosuitable point complete as required.Fixture Similar to Wipro Cat No.: LD80-171-XXX-60-XX or Equivalent

Each 75 -

MR 50 12.1.6

Supply of 4 ft linear 36W-40W surface mounting type LED luminaire, IP 65,colour temperature 5700K having efficacy not less than 100 lm/W, THD ≤20%, PC housing, suitable diffuser, inbuilt electronic driver, including 3 core1.5 sq.mm FRLS PVC insulated and PVC sheathed copper conductor cable andearthing etc. upto suitable point complete as required.Fixture similar to WIPRO CAT : LE20-491-XXX-57-XX or Equivalent

Each 140 -

WAPCOS Ltd.Signature of Bidder

Ref. No. S.NO. DESCRIPTION UNIT RATE QUANTITY AMOUNT

MR 51 12.1.7

Supply of 4 ft linear 18W-20W surface mounting type LED luminaire, IP 65,colour temperature 6500K having efficacy not less than 100 lm/W, THD ≤20%, PC / PMMA housing, suitable diffuser, inbuilt electronic driver, including3 core 1.5 sq.mm FRLS PVC insulated and PVC sheathed copper conductorcable and earthing etc. upto suitable point complete as required.Fixture similar to WIPRO CAT : LL20-221-XXX-65-NE1 or Equivalent

Each 10 -

MR 52 12.1.9

Supply of linear bulk head light 9W-10W surface mounting type LEDluminaire, IP 65 ,colour temperature 5700K having efficacy not less than 80lm/W, THD ≤ 20%, die cast aluminium housing, suitable diffuser, inbuiltelectronic driver, including 3 core 1.5 sq.mm FRLS PVC insulated and PVCsheathed copper conductor cable and earthing etc. upto suitable pointcomplete as required.Fixture similar to WIPRO CAT : LW07-141-XXX-57-XX or Equivalent

Each 10 -

MR 53 12.1.10

Supply, installation, testing & commissioning of LED FLOOD Light Luminaireconsuming a system wattage of 80W (±10%) & the luminaire shall be withsystem efficacy ≥ 85lm/W. Housing: Die Cast Aluminium . IP66 , Optics: PCReflector. The operating CCT shall be 5700K with CRI of ≥70. The luminaireshall be with BIS Registered electronic driver with input voltage range of 150to 270V , THD ≤ 10% & PF ≥ 0.9, 50,000 Hrs LED Life with L70 Criteria.The LEDDriver shall be easily avaiable in India for repair and service. The LED shall beSMD type. Luminaire shall have minimum surge protection of 4KV.Theluminaire shall be with following certifications: LM79 & LM80 issued by LEDmanufacture along with Photo Biological Safety Standard.Fixture similar to Wipro Cat No.: LF19-931-060-57-XX or equivalent

Each 4 -

MR 54 12.4

Supply, installation, testing & commissioning of LED Street Light Luminaireconsuming a system wattage of 35W (±10%) & the luminaire shall be withsystem efficacy ≥ 100lm/W. Housing: Die Cast Aluminium . IP66 , Optics:Toughened Glass . The operating CCT shall be 5700K with CRI of ≥70. Theluminaire shall be with BIS Registered electronic driver with input voltagerange of 150 to 270V , THD ≤ 10% & PF ≥ 0.9, 50,000 Hrs LED Life with L70Criteria.The LED Driver shall be easily avaiable in India for repair and service.The LED shall be SMD type. Luminaire shall have minimum surge protectionof 4KV.The luminaire shall be with following certifications: LM79 & LM80issued by LED manufacture along with Photo Biological Safety Standard.Fixture similar to Wipro Cat No.: Wipro Cat No.:LR02-391-XXX-57-XX orequivalent

Each 30 -

WAPCOS Ltd.Signature of Bidder

Ref. No. S.NO. DESCRIPTION UNIT RATE QUANTITY AMOUNT

MR 55 12.5

Supply & Installation of 3.0 mtr. long GI street light pole 4.5 mm walthickness having 114 mm outer uniform dia. and 60.3 mm dia., 3.6 mm thick100 mm long coller along with base plate of size 300 mm x 300 mm x 12 mmthick, suitable for mounting of 1 no. light fixture. Pole should be finished withadaquate size flush door with openable chained cover in lower section withproper strengthning of cutout of door opening including necessary rubbergasket with two coats of pu paint of approved shade, supplying & fixing ofsuitable size SP MCB , neutral link, earth stud, heavy duty connector (suitablefor 16 sq.mm terminations) complete as required.

Note :1. The pole shall be either of same make as that of street light fixture orequivalent2. The pole shall be installed in cement concrete 1:3:6 (1 cement : 3 Coarsesand : 6 graded stone aggregate of 40 mm nominal size) foundation minimumsize of 0.21 cum including excavation and refilling etc. as required. Providingand fixing Foundation Bolt- M16 x 450 mm.(4Nos.) with nuts and and washercomplete as required.

Each 30 -

12.11

Supply of BEE 5star rated following ceiling fan, including wiring, the downrods of standard length (upto 30 cm) with 3x1.5 sqmm FRLS PVC insulatedcopper conductor single core cables etc., as required to do the job in allrespect in accordance with laid specification or upto the satisfaction ofengineer in charge.

MR 56 12.11.1 1200 mm sweep ceiling fan Each 20 -

MR 57 12.12

Supply of 300mm size exhaust fan suitable for 230V, 50 Hz AC includingmodifying and finishing for hole/opening for the size of fan, MS louver/shutter complete with frame for Ex.fan including its connection with 3x1.5 sqmm FRLS copper conductor wire with PVC sleeve, loop earthing, making thegood damage complete as required to do the job in all respect in accordancewith laid specification or upto the satisfaction of engineer in charge.

Each 5 -

Subtotal carried over to summary -13 CHAPTER 13: CIVIL WORKS

14.15 13.1

Supplying and laying of following size DWC HDPE pipe ISI marked along withall accessories like socket, bend, couplers etc. conforming to IS 14930, Part IIcomplete with fitting and cutting, jointing etc. in the existing trench, completeas required.

14.15.1 13.1.1 63 mm dia (OD-63 mm & ID-51 mm nominal) Meter - -14.15.3 13.1.1 120 mm dia (OD-120 mm & ID-103 mm nominal) Meter 100 -14.15.5 13.1.2 200 mm dia (OD-200 mm & ID-175 mm nominal) Meter - -

14.4 13.2

Excavation for cable trenches in soft soil, depth upto 1.2 m including dressingof sides lift upto 1.5 m, including getting out the excavated soil, refilling withsand and or good soil after laying of cable/ pipe etc. in layers of 20 cm,ramming, watering and disposal of surplus excavated soil as directed, within alead of50 meter.

Cum 150 -

14.14 13.3Providing, laying and fixing following dia RCC pipe NP2 class (light duty) inground complete with RCC collars, jointing with cement mortar 1:2 (1 cement: 2 fine sand) including trenching (75 cm deep) and refilling etc. as required.

14.14.1 13.3.1 100 mm dia Meter 20 -14.14.2 13.3.2 150 mm dia Meter 20 -14.14.3 13.3.3 250 mm dia Meter 200 -14.14.4 13.3.4 300 mm dia Meter -

WAPCOS Ltd.Signature of Bidder

Ref. No. S.NO. DESCRIPTION UNIT RATE QUANTITY AMOUNT

Civil DSR19.7

14.4

Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix(1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarsesand) finished with floating coat of neat cement and making channels incement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate20 mm nominal size) finished with a floating coat of neat cement complete asper standard design :

Civil DSR19.7.1

14.4.1Inside size 90x80 cm and 45 cm deep including C.I. Cover with frame (lightduty) 455x610 mm internal dimensions, total weight of cover and frame to benot less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :

Civil DSR19.7.1.1

14.4.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Each 10 -

Civil DSR19.7.2

14.4.2Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavyduty) 910x555 mm, total weight of cover and frame to be not less than 208kg (weight of cover 108 kg and weight of frame 100 kg) :

Civil DSR19.7.2.1

14.4.2.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Each - -

Civil DSR19.8

14.5 Extra for depth for manholes :

Civil DSR19.8.1

14.5.1 Size 90X80 cm

19.8.1.1 14.5.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Meter 8 -

Civil DSR19.8.2

14.5.2 Size 120x90 cm

19.8.2.1 14.5.2.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Meter - -

MR 58 13.6

Providing & fixing in position 1000 mm wide , Electrical Insulating RubberMats as per IS 15652:2006, 2 mm thick, suitable up to 11 KV , fire retardant,no effect of acids, alkalis and transformer oils, moisture proof, high tensilestrength and texture finish / cloth impression (Anti slip , marking on top)

Metre 20 -

MR 59 13.6

Providing & fixing in position 1000 mm wide , Electrical Insulating RubberMats as per IS 15652:2006, 2 mm thick, suitable up to 1.1 KV , fire retardant,no effect of acids, alkalis and transformer oils, moisture proof, high tensilestrength and texture finish / cloth impression (Anti slip , marking on top)

Metre 20 -

MR 60 13.7Supply & fixing shock treatment chart duly mounted on a wooden frame with5 mm thick glass as required ( approx front area 1.20 Sq Metre )

Each 2 -

OSR 20182.13

13.8Providing and fixing M.V danger board of 200 mm x 150 mm made mild steelat least 2 mm thick and vitreous enameled white on both sides and withinscription in single red colours on front side as required.

Each 2 -

MR 61 13.9

Supplying and making cable route marker with cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) ofsize 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with athickness of 10cm including inscription duly engraved as required.

Each 25 -

MR 62 13.10Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I.plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mmangle iron, 60 cm long and fixing the same in ground as required.

Each 25 -

Subtotal carried over to summary -

14CHAPTER-14 : STURUCTURED CABLING FOR DATA AND NETWORKING

MR 63 14.1

Supply & Installation of CAT 6 information outlets complying fully orexceeding with category 6 connecting hardware specifications for all paircombinations up to 250 MHz. Outlets shall use lead frame technology, nonPCB pyramid type. complete as required and as per technical specifications.

Each 20 -

WAPCOS Ltd.Signature of Bidder

Ref. No. S.NO. DESCRIPTION UNIT RATE QUANTITY AMOUNT

MR 64 14.3Supply & Installation of Quad, triplex, dual, single Face Plates along withclearly printed labels and holders complete as required specifications. Each 20 -

MR 65 14.7

Supply & Installation of Cat 6 Mounting Cords 4 feet length for the Rack EndConnectivity to the System, End shall be RJ 45 with snagless boots. (Yellow incolour for Data) complete as required and as per technical specifications.

Each 20 -

MR 66 14.8

Supply & Installation of Cat 6 Mounting Cords 7 feet length for the User EndConnectivity to the System, End shall be RJ 45 with snagless boots. (Yellow incolour for Data) complete as required and as per technical specifications.

Each 20 -

1.53 14.90Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/recessed Steel/ PVC conduit as required.

1.53.1 14.9.1 1 run of cable Meter 1,400 -

MR 67 14.11

SITC 42U Floor Standing 19" Networking Enclosure Closed rack with FrontGlass door, rear steel door, castors, 4 fans with fan tray, power strips andcomplete with all accessories as required. (upto size - 800mmW x 1000mmD)as required.(along with Horizontal Cable manager and vertical Cablemanager, PDU with minimum 12 nos. 16 Amp Socket)

Each - -

MR 68 14.12

SITC 15U wall mounted Networking Enclosure Closed rack with Front Glassdoor, rear steel door, castors, fans with fan tray, power strips and completewith all accessories as required. (upto size - 800mmW x 1000mmD) asrequired.(along with Horizontal Cable manager and vertical Cable manager,PDU with required 16 Amp Socket)

Each 2 -

MR 69 14.25Supply, of outdoor 6 core armoured Single mode fiber optic cable for outdoorconnectivity where ever required in prelaid conduits / RCC humepipes/HDPE/DWC, whichever maybe available etc. as required.

Metre 200 -

MR 70 14.29Supplying and fixing in position MS anodised box for data/voice outletsuitable for fixing of RJ 45 jack complete as required. (For Data/voice outlets) Each 20 -

1.19 14.30

Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copperconductor PE insulated, shielded with fine tinned copper braid and protectedwith PVC sheath in the existingsurface/ recessed steel/ PVC conduit as required.

Meter 500 -

MR 71 14.31Supply, of 8 Way tap off for taking TV cable taps from main riser from dishantenna to be installed inside the shaft etc as reqired.

Each 1 -

MR 72 14.32Supply, of 6 way splitter for TV made up of solid metal die cast housing with 1male and 6 female complete as required.

Each 2 -

1.20 14.33Supplying and fixing of following sizes of steel conduit along with accessoriesin surface/recess including painting in case of surface conduit, or cutting thewall and making good the same in case of recessed conduit as required.

1.20.2 14.33.1 25 mm Metre 400 -1.20.3 14.33.2 32 mm Metre 100 -

Subtotal carried over to summary -15 CHAPTER-15: IP BASED CCTV SYSTEM

MR 73 15.1

Supply, of IP DOME (Indoor): 2mp @ 25 fps, H.265 Compression, 1/3" LowIllumination Aptina Cmos, Hisilicon DSP, IP Vandal Dome Camera with 2megapixel HD 2.8 - 12mm Lens, 30 IR LED upto 25 meters, Supports iOS &Android Apps. Supports ONVIF. IP65 Protection Rating. Supports POE. Shouldsupport rest all features of IP camera such as Multi Streaming, ImageSnapshot, Full Screen Monitoring, Supports CBR & VBR, Motion Alarm, OnlineUsers upto 10, Video Format in AVI & JPEG, Supports Video Playback andDelete. Supports D-WDR, 3D-DNR, ICR, Brightness, Contrast, Hue, NightMode, Supports TCP/IP, UDP, DHCP, FTP, DDNS, PPPoE, Supports Cell phone,PDA, 3GPP. ONVIF Support. IP65 Rating etc all complete

Each 12 -

WAPCOS Ltd.Signature of Bidder

Ref. No. S.NO. DESCRIPTION UNIT RATE QUANTITY AMOUNT

MR 74 15.20

Supply, of IP BULLET (Outdoor):2mp @ 25 fps, H.264 Compression, 1/3" LowIllumination Aptina Cmos, Hisilicon DSP, IP Bullet Camera with 2 megapixelHD 2.8 - 12mm Lens, 30 IR LED upto 30 meters, Supports iOS & Android Apps.Supports ONVIF. IP66 Protection Rating. Supports POE. Should support rest allfeatures of IP camera such as Multi Streaming, Image Snapshot, Full ScreenMonitoring, Supports CBR & VBR, Motion Alarm, Online Users upto 10, VideoFormat in AVI & JPEG, Supports Video Playback and Delete. Supports D-WDR,3D-DNR, ICR, Brightness, Contrast, Hue, Night Mode, Supports TCP/IP, UDP,DHCP, FTP, DDNS, PPPoE, Supports Cell phone, PDA, 3GPP. ONVIF Support.IP66 Rating etc all complete

Each 4 -

MR 75 15.30

Supply, of Network Video Rrecorder, H.265 decoding. -32 Channel IP camerasinputs, 32 Audio In & 1 Audio Out, 1 Video out @ VGA(1080P), 2 HDMI out(1080P). Real-time Display & 16Ch Playback, Dual Stream Recording, Recordresolution 5MP/ 4MP/3MP/1080P/960P/720P, Recording Mode in Manual,Schedule & Alarm, Recording & Playback Up to 720P @ PAL per CH, 8x SATAHDD port upto 6TB each, eSata x 2, 8 alarm input & 4 output, 2 x Networkethernet Interface supports 10/100/1000 Mbps, Multi-Remote Client upto 10,backup by 2 x USB, With remote control & USB interface for mouse. Networkbandwidth of 256 Mbps Supports DDNS, PTZ Control, RS-485, Digital Zoom,Motion Detection, Video Loss, Alarm recording, Buzzer, Each Channel Backup,Password Control, Firmware Update and Mobile applications.all complete etcall complete

Each 1 -

MR 76 15.40

Supply, of VMS Software supporting upto 256 Cameras. Unlimited clientaccess, PTZ Control, Remote Viewing, Remote Storage, Playback. SupportsJPEG, AVI, WAV export formats, Hourly schedules, Email Notification. Thisincludes Camera and Base licenses all complete

Each 1 -

15.50

Supply, installation, testing & commissioning with proper connection &termination of following size equipment rack made out of CRCA sheet tohouse all the control equipment complete as required in accordance with laidspecification or upto the satisfaction of engineer in charge.

MR 77 15.5.1 19" equipment rack -6 U Each 2 -MR 78 15.5.2 19" equipment rack -15 U Each 1 -

MR 79 15.60

Supply, of Layer-3 Distribution Switch 24 Gigabit Ports, Rack Mountable, 4Port SFP+ 10GpE, including Fibre module for LAN base feature set withsupport to integration with CCTV, with all related hardware

Each 1 -

MR 80 15.70

Supply, of Layer-2 PoE Distribution Switch 24 Gigabit Ports, Rack Mountable,4 Port SFP+ 10GpE, POE+ Switch including Fibre module for LAN base featureset with support to integration with CCTV, with all related hardware Each 1 -

MR 81 15.80

Supply, of Layer-2 PoE Distribution Switch 8 Gigabit Ports, Rack Mountable, 4Port SFP+ 10GpE, POE+ Switch including Fibre module for LAN base featureset with support to integration with CCTV, with all related hardware Each 1 -

MR 82 15.90

Supply, of 21" colour TFT Monitor including decodes and all accessoriescomplete as required in accordance with laid specification or upto thesatisfaction of engineer in charge.

Each 1 -

WAPCOS Ltd.Signature of Bidder

Ref. No. S.NO. DESCRIPTION UNIT RATE QUANTITY AMOUNT

MR 83 15.10

Supply installation, testing and commissioning of Desktop Computercomprising CPU, Keyboard and a mouse complete with operating system (OS)and other required software to control NVR in control room includingCentralized Video Management Software as per the requirement of thesuccessful operation of the surveillance system complete as required inaccordance with laid specification or upto the satisfaction of engineer incharge.

Each 1 -

MR 84 15.13

Supply, installation Testing and commissioning of compatible mediaconverter for the interconnection of switches on optical Fiber cable backbone, complete with patch cord, 3-LIU-6port,1 LIU-24Port units and junction boxesas required for integration as per specification complete as requiredincluding all support as required.

Each 2 -

MR 85 15.14Supply, of outdoor armoured Single mode fiber optic cable for outdoorconnectivity where ever required in prelaid conduits / raceways / HDPE /DWC pipes, whichever maybe available etc. as required

Each 500 -

1.53 15.11Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/recessed Steel/ PVC conduit as required.

1.53.1 15.11.1 1 run of cable Meter 1,400 -

1.20 15.12Supplying and fixing of following sizes of steel conduit along with accessoriesin surface/recess including painting in case of surface conduit, or cutting thewall and making good the same in case of recessed conduit as required.

1.20.2 15.12.1 25 mm Metre 200 -1.20.3 15.12.2 32 mm Metre 100 -

Subtotal carried over to summary -16 CHAPTER-16 : FIRE ALARM & PUBLIC ADDRESS SYSTEM

Irrespective of whether or not mentioned in the BoQ, all necessary interfaces -such as hardware including any fiber optics modules, if required and/orsoftware - for interconnecting all fire alarm panels at site shall be provided inthe system(s).All the fire panels at site shall be operated and monitored in networked modeand shall be integrated with IBMS system over BacNet/IP protocol; allnecessary hardware and software applications and licences for the same shallbe provided by the vendor.

17.2.1 16.1

Supplying, installation, testing and commissioning of microprocessor basedintelligent addressable main fire alarm panel, central processing unit with thefollowing loop modules and capable of supporting not less than 240 devices(including detectors) and minimum 120 detectors per loop and loop length upto 2 km, network communication card,minimum 320 character graphics/ LCDdisplay with touch screen or other keypad and minimum 4000 events historylog in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50hz), 48 hrs back-up with 24 volt sealed maintenance free batteries withautomatic charger. The panel shall have facility to connect printer to printoutlog and facility to have seamless integration with analog/digital voiceevacuation system (which is part of the schedule of work under SH: PASystem) and shall be complete with all accessories . The panel shall becompatible for IBMS system with open protocol BACnet/ Modbus over IPcomplete as per specifications.17.2.1.2 16.1.2 Two Loop panel Each 1 -

17.2.3 16.2Supply, installation, testing & commissioning of repeater panel with minimum320 character touch screen LCD display with inbuilt reset acknowledge andsilence switch complete as required.

Each - -

17.2.4 16.3Supply of intelligent analog addressable photothermal detector completewith mounting base complete as required.

Each 50 -

17.2.7 16.4 Supply of fault isolator complete with base as required. Each 2 -

17.2.9 16.5Supply of intelligent addressable thermal detector with rate of rise cum fixedtempreature thermistor complete with base as required.

Each 2 -

17.2.5 16.7Supply of response indicator on surface/recessed MS Box having twoLED,metallic cover complete with all connections etc as required.

Each 20 -

WAPCOS Ltd.Signature of Bidder

Ref. No. S.NO. DESCRIPTION UNIT RATE QUANTITY AMOUNT17.2.14 16.8 Supply of addressable manual call point complete as required. Each 10 -

17.2.19 16.9Supply, installation, testing & commissioning of Fire Fighter's Telephone Jackcomplete as required.

Each 2 -

17.2.17 16.11 Supply of fire fighter telephone handset complete as required. Each 2 -17.2.15 16.12 Supply of addressable horn cum strobe complete as required. Each 10 -

17.2.12 16.12Supply of addressable beam detector with short circuit isolator (inbuilt orseperate) complete with emitter and receiver including connections withremote test features etc complete as required.

Each 4 -

MR 86 16.13

Supply, installation, testing & Commissioning of UL Listed addressablemonitor module complete as required in accordance with laid specificationor upto the satisfaction of engineer in charge. (For monitoring of sprinklerflow switch, Developer's fire panel, WLD Panel)

Each 2 -

17.2.10 16.14

Supply of addressable fire control module complete as required.For control of AHU's, VRV, Hooters ,output to PA system, for integration withAccess Control, Developer's Fire Panel etc. complete as required and as perspecifications.

Each 8 -

17.5.1 16.21

Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000Vrated with annealed copper conductor having glass mica fire barrier tapecovered by an extruded layer of Cross Linkable Ethylene Propylene Rubber(EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outersheath complete as required.

Metre 750 -

1.20 16.24Supplying and fixing of following sizes of steel conduit along with accessoriesin surface/recess including painting in case of surface conduit, or cutting thewall and making good the same in case of recessed conduit as required.

1.20.2 16.24.1 25 mm Metre 500 -

MR 88 16.24.325 mm dia GI flexible conduit with all fixing accessories.

Metre 50 -

Subtotal carried over to summary -

WAPCOS Ltd.Signature of Bidder

SI.NO. DESCRIPTION AMOUNTA CHAPTER 1: SANITARY FIXTURES -

B CHAPTER 2: INTERNAL DRAINAGE -

C CHAPTER 3: WATER SUPPLY -

D CHAPTER 4: EXTERNAL SEWAGE AND STORM WATER -

F CHAPTER 5: DRINKING WATER TREATMENT STATION -

Fire Fighting Works

A CHAPTER 1: FIRE PUMPS AND ALLIED ACCESORIES -

B CHAPTER 2: INTERNAL HYDRANT -

C CHAPTER 3: PIPING, VALVES AND ALLIED -

D CHAPTER 4: EXTERNAL HYDRANT -

E CHAPTER 5: FIRE EXTINGUISHER -

PROJECT - CONSTRUCTION OF MULTIPURPOSE INDOOR HALL AT KALINGA SPORTSSUMMARY OF WORKS (PLUMBING & FIRE FIGHTING WORKS)

WAPCOS Ltd.Signature of Bidder

SUB-TOTAL -

WAPCOS Ltd.Signature of Bidder

DSR No. SI.NO. DESCRIPTION UNIT QUANTITY RATE AMOUNTCHAPTER 1: SANITARY FIXTURES

17.1 1.1

Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mmsand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flushpipe, with manually controlled device (handle lever) conforming to IS : 7231, with allfittings and fixtures complete, including cutting and making good the walls and floorswherever required :

17.1.1White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral typefoot rests

each 2.00 0.00

17.81 1.2

Providing and fixing floor mounted, white vitreous china single piece, double trapssyphonic water closet of approved brand/ make, shape, size and pattern includingintegrated white vitreous china cistern of capacity 10 litres with dual flushing system,including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasketetc including making connection with the existing P/S trap, complete in all respect asper directions of Engineer-in-Charge.

each 13.00 0.00

17.16A 1.3Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long withS.S. triangular plate to Eureopean type W.C. of quality and make as approved byEngineer - in - charge.

each 13.00 0.00

17.10 1.4Providing and fixing stainless steel A ISI 304 (18/8) Kitchensink as per IS : 13983 with CIbracket and stainless steel plug 40 mm including painting of fittings and brackets,cutting and making good the walls wherever required:

0.00

17.10.1 Kitchen sink with drain board 0.0017.10.1.3 500 x 1040 mm bowl depth 200 mm each 1.00 0.00

17.22A 1.5Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make andas per the direction of Engineer-in-charge.

each 16.00 0.00

17.22B 1.6Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make asapproved by Engineer in charge.(a) 15 mm nominal dia

each 1.00 0.00

17.31 1.7Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approvedquality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P.brass screws and washers complete.

each 16.00 0.00

17.34 1.8 Providing and fixing toilet paper holder : 0.0017.34.1 C.P. brass each 13.00 0.00

PROJECT - CONSTRUCTION OF MULTIPURPOSE INDOOR HALL AT KALINGA SPORTS COMPLEX, BHUBANESWAR, ODISHADETAILED ESTIMATE (PLUMBING & FIRE FIGHTING)

3 WAPCOS Ltd.Signature of Bidder

DSR No. SI.NO. DESCRIPTION UNIT QUANTITY RATE AMOUNT

17.80 1.9

Providing and fixing white vitreous china battery based infrared sensor operated urinalof approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml &500 ml consumption), having water inlet from back side, including fixing to wall withsuitable brackets all as per manufacturers specification and direction of Engineer-in-charge.

each 11.00 0.00

18.21 1.10 Providing and fixing uplasticised PVC connection pipe with brass unions : 0.0018.21.1 30 cm length 0.00

18.21.1.2 20mm nominal bore each 50.00 0.0018.49 1.11 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 0.00

18.49.1 15 mm nominal bore. each 5.00 0.00

18.50 1.12Providing and fixing C.P. brass long nose bib cock of approved quality conforming to ISstandards and weighing not less than 810 gms.

0.00

18.50.1 15 mm nominal bore. each 2.00 0.00

18.53 1.13Providing and fixing C.P. brass angle valve for basin mixer and geyser points ofapproved quality conforming to IS:8931

0.00

18.53.1 15 mm nominal bore each 50.00 0.00

17.28 1.14Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. wastefittings complete.

0.00

17.28.2 Flexible pipe 0.0017.28.2.1 32 mm dia each 2.00 0.0017.28.2.2 40 mm dia each 2.00 0.00

8.10 1.15

Providing and fixing stone slab with table rubbed, edges rounded and polished, of size75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase ofappropriate width with chase cutter and embedding the stone in the chase with epoxygrout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 6 mm nominal size) as per direction of Engineer-in-charge and finishedsmooth.

0.00

8.10.2 Granite Stone of approved shade sqm. 4.13 0.00

MR-1 1.16

Providing and Fixing C.P. brass towel ring "Round" fixed to PVC cleats with C.P. brassscrews including cutting and making good the walls wherever required complete asper direction of the engineer-in-charge.(Model No. Jaquar ACN-1121N or equivalent)

each 8.00 0.00

4 WAPCOS Ltd.Signature of Bidder

DSR No. SI.NO. DESCRIPTION UNIT QUANTITY RATE AMOUNT

MR-2 1.17Providing and fixing soap dish of approved quality and colour complete as perdirection of the engineer-in-charge.(Model No. Jaquar ACN-1131N or equivalent)

each 2.00 0.00

MR-3 1.18

Providing and fixing counter top/under counter Oval shape wash basin withh C.I.brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard patternincluding painting of fittings and brackets, cutting and making good the walls whereverrequire:(Model No. Hindware starwhite 10017 or equivalent)

0.00

White Vitreous China Wash basin size 560 x 410 mm each 16.00 0.00

MR-4 1.19

Providing and fixing 600mm long CP Brass towel rail complete with brackets fixed towooden cleats with CP brass screws with concealed fitting arrangement of approvedquality and colour.(Model No. Parryware T600A1 or equivalent)

each 2.00 0.00

MR-5 1.20Providing and fixing C.P cast brass Double coat hook fixed to PVC cleats with C.P. brassscrews complete as per instructions of the engineer-in-charge.(Model No. Jaquar ACN 1161N or equivalent)

each 17.00 0.00

MR-6 1.21

Providing and Fixing 600 mm long Hand rail (Grab bar) for Handicap Toilets withStainless Steel Screws on wooden cleats complete as per instructions of the engineer-in-charge(Model No. Viking or equivalent)

each 4.00 0.00

MR-7 1.22Providing and Fixing C.P. Sliding Rail with stainless steel screws on plastic cleantscomplete in all respects as per the Engineer- In -charge.(Model No. Kosmos Care or equivalent)

each 2.00 0.00

MR-8 1.23

Providing and fixing vertical or horizontal storage type hot water heater fixed to wallwith anchor bolts & nuts, 15mm CP brass angle stop cock and 15mm CP brass non-return valve complete including making connections with 15mm dia CP connectingpipes on inlet and outlet, suitable length of power cable and 15 amps plug .

0.00

25 Litre Capacity (Model No. Havells Puro Turbo or equivalent) each 3.00 0.0018.22 1.24 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 0.00

18.22.1 100 mm diameter each 2.00 0.00

18.52 1.25Providing and fixing C.P. brass stop cock (concealed) of standard design and ofapproved make conforming to IS:8931.

0.00

18.52.1 15 mm nominal bore each 4.00 0.00SUB-TOTAL 0.00

5 WAPCOS Ltd.Signature of Bidder

DSR No. SI.NO. DESCRIPTION UNIT QUANTITY RATE AMOUNTCHAPTER 2: INTERNAL DRAINAGE 0.00

12.22 2.1

Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size)over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1cement : 3 coarse sand) and a coat of neat cement, rounding the edges and makingand finishing the outlet complete.

each 15.00 0.00

17.35 2.2 Providing and fixing soil, waste and vent pipes : 0.0017.35.1 100 mm dia. 0.00

17.35.1.3 Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 metre 125.00 0.00

12.41 2.3Providing and fixing on wall face uplasticised Rigid PVC rain water pipes conforming toIS 13592 Type A including jointing with steel ring conforming to IS 5382 leaving 10 mmgap for thermal expansion (i) single socketed pipes.

0.00

12.41.2 110 mm dia metre 216.00 0.00

12.42 2.4

Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories forunplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, includingjointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermalexpansion.

0.00

12.42.2 Single pushfit Coupler 0.0012.42.2.2 110 mm each 72.00 0.0012.42.3 Single tee with door 0.00

12.42.3.2 110 x 110 x 110 mm each 18.00 0.0012.42.6 Shoe (Plain) 0.00

12.42.6.2 110 mm each 18.00 0.00

12.44 2.5Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cmdiameter and weighing not less than 440 grams.

each 18.00 0.00

17.59 2.6Providing and fixing M.S. stays and clamps for sand cast iron/centrifugally cast (spun)iron pipes of diameter :

0.00

17.59.1 100 mm each 113.67 0.00

17.38 2.7Providing and fixing bend of required degree with access door, insertion rubberwasher 3 mm thick, bolts and nuts complete.

0.00

17.38.1 100 mm 0.00

17.38.1.3 Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 each 5.00 0.00

17.39 2.8 Providing and fixing plain bend of required degree. 0.0017.39.1 100 mm dia. 0.00

6 WAPCOS Ltd.Signature of Bidder

DSR No. SI.NO. DESCRIPTION UNIT QUANTITY RATE AMOUNT

17.39.1.3 Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 each 30.00 0.00

17.42 2.9 Providing and fixing double equal plain junction of required degree. 0.0017.42.1 100x100x100x100 mm 0.00

17.42.1.3 Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 each 2.00 0.00

17.44 2.10 Providing and fixing single equal plain junction of required degree : 0.0017.44.1 100x100x100 mm 0.00

17.44.1.3 Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 each 20.00 0.00

17.54A 2.11Providing and fixing Hubless centrifugally cast iron offsets epoxy coated inside &outside as per IS:15905

0.00

17.54A.1 130 mm offsets 0.0017.54A.1.1 With 100 mm dia each 2.00 0.00

17.56 2.12 Providing and fixing terminal guard : 0.0017.56.1 100 mm dia. 0.00

17.56.1.3 Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 each 12.00 0.00

17.57A 2.13 Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe 0.0017.57A.1 100 mm dia 0.00

17.57A.1.1 SS 304 grade coupling with EPDM rubber gasket each 153.67 0.00

17.60 2.14Providing and fixing trap of self cleansing design with screwed down or hinged gratingwith or without vent arm complete, including cost of cutting and making good thewalls and floors :

0.00

17.60.1 100 mm inlet and 100 mm outlet 0.00

17.60.1.3 Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 each 22.00 0.00

17.61 2.15

Cutting chases in brick masonry walls for following diameter sand cast iron/centrifugally cast (spun) iron pipes and making good the same with cement concrete1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 12.5 mm nominal size),including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarsesand) :

0.00

17.61.1 100 mm dia metre 15.00 0.00

18.10 2.16Providing and fixing G.I. pipes complete with G.I. fittings and clamps,i/c cutting and making good the walls etc.

0.00

7 WAPCOS Ltd.Signature of Bidder

DSR No. SI.NO. DESCRIPTION UNIT QUANTITY RATE AMOUNTInternal work - Exposed on wall 0.00

18.10.6 50 mm dia metre 35.00 0.00

MR-9 2.17

Providing and Fixing G.I. Reducing elbow of 100 x 50 mm in cement concrete 1:2:4 atall levels for floor drains (exlcuding cost of grating) for connection to floor traps insunken portions, complete as per drawings and as per approval of the engineer-in-charge.(GI Pipe for connecting elbow with floor trap shall be measured seperately )

each 15.00 0.00

MR-10 2.18

Providing and fixing G.I. Inlet fitting with maximum 3 inlets 32,40 & 50 mm sizefabricated from 100 mm dia G.I. pipes and welded G.I. sockets as per site locations,fixed to C.I. Trap and set with proper sealing compound as per drawing complete asper approval of the engineer-in-charge.

each 15.00 0.00

MR-11 2.19

Providing and fixing cast brass Floor Clean Out plug with suitable insert keys foropening, male threaded joint with G.I. socket drip seal to soil pipe / waste pipe of C.I.pipe as required complete as per drawing, approved sample and direction by Engineer-in-charge:

0.00

100 mm dia each 15.00 0.00SUB-TOTAL 0.00CHAPTER 3: WATER SUPPLY 0.00

18.8 3.1

Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threaded fittings,i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes &fittings with one step CPVC solvent cement and the cost of cutting chases and makinggood the same including testing of joints complete as per directionof Engineer in Charge.

0.00

Concealed work, including cutting chases and making good the walls etc. 0.0018.8.1 15 mm nominal outer dia Pipes metre 95.00 0.0018.8.2 20 mm nominal outer dia Pipes metre 88.00 0.0018.8.3 25 mm nominal outer dia Pipes metre 55.00 0.0018.8.4 32 mm nominal outer dia Pipes metre 35.00 0.00

18.9 3.2

Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply including all CPVC plain & brass threaded fittingsThis includes jointing of pipes & fittings with one step CPVC solvent cement, trenching,refilling & testing of joints complete as per direction of Engineer in Charge.

0.00

External Works 0.00

8 WAPCOS Ltd.Signature of Bidder

DSR No. SI.NO. DESCRIPTION UNIT QUANTITY RATE AMOUNT18.9.6 50 mm nominal outer dia Pipes metre 15.00 0.00

18.7 3.3

Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermalstability for hot & cold water supply, including all CPVC plain & brass threaded fittings,including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings with one step CPVC solvent cement and testing of joints complete as perdirection of Engineer in Charge.

0.00

Internal work - Exposed on wall 0.0018.7.1 15 mm nominal outer dia Pipes metre 25.00 0.0018.7.2 20 mm nominal outer dia Pipes metre 35.00 0.0018.7.3 25 mm nominal outer dia Pipes metre 38.00 0.0018.7.4 32 mm nominal outer dia Pipes metre 25.00 0.0018.7.5 40 mm nominal outer dia Pipes metre 18.00 0.0018.7.6 50 mm nominal outer dia Pipes metre 32.00 0.00

18.17 3.4Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwedend) :

0.00

18.17.1A 20 mm nominal bore each 5.00 0.0018.17.1 25 mm nominal bore each 2.00 0.0018.17.2 32 mm nominal bore each 4.00 0.0018.17.3 40 mm nominal bore each 6.00 0.0018.17.4 50 mm nominal bore each 7.00 0.00

18.48 3.5

Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI: 12701 marked with cover and suitable locking arrangement and making necessaryholes for inlet, outlet and overflow pipes but without fittings and the base support fortank.Circular tank.

per litre 20000.00 0.00

SUB-TOTAL 0.00CHAPTER 4: EXTERNAL SEWAGE AND STORM WATER 0.00

19.1 4.1Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture ofcement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing ofjoints etc. complete :

0.00

19.1.2 150 mm diameter metre 10.00 0.00

19.4 4.2

Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. gratingbrick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than2.70 kg as per standard design:

0.00

19.4.1 100x100 mm size P type 0.00

9 WAPCOS Ltd.Signature of Bidder

DSR No. SI.NO. DESCRIPTION UNIT QUANTITY RATE AMOUNT19.4.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 each 5.00 0.00

19.6 4.3Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collarsjointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 finesand) including testing of joints etc. complete :

0.00

19.6.2 150 mm dia. R.C.C. Pipe metre 155.00 0.00

19.7 4.4

Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand )with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stoneaggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarsesand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floatingcoat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floatingcoat of neat cement complete as per standard design :

0.00

19.7.1Inside size 90x80 cm and 45 cm deep including C.I. Cover with frame (light duty)455x610 mm internal dimensions, total weight of cover and frame to be not less than38 kg (weight of cover 23 kg and weight of frame 15 kg) :

0.00

19.7.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 each 15.00 0.0019.8 4.5 Extra for depth for manholes : 0.00

19.8.1 Size 90x80 cm 0.0019.8.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 metre 10.00 0.00

19.16 4.6

Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulatedas per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimumcross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on topsurface by ribbing or chequering besides necessary and adequate anchoringprojections on tail length on 138 mm as per standard drawing and suitable to withstand the bend test and chemical resistance test as per specifications and havingmanufacture's permanent identification mark to be visible even after fixing, includingfixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominal size) complete as per design.

each 75.00 0.00

19.19 4.7Providing and fixing in position pre-cast R.C.C. manhole cover and frame of requiredshape and approved quality

0.00

19.19.3 H D - 20 0.0019.19.3.1 Circular shape 560 mm internal diameter each 5.00 0.00

10 WAPCOS Ltd.Signature of Bidder

DSR No. SI.NO. DESCRIPTION UNIT QUANTITY RATE AMOUNT

19.27 4.8Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cementmortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontalgrating with frame complete as per standard design :

0.00

19.27.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 each 10.00 0.00SUB-TOTAL 0.00CHAPTER 5: DRINKING WATER TREATMENT STATION 0.00

MR-12 5.1

Supply, Installation, Testing & Commisioning of Reverse Osmosis unit based waterPurifier (wall mounted) of 50LPH capacity to treat the raw water having TDS 1500 ppmand reducing TDS to 80ppm and hardness less than 50 ppm or as per WHO standards.The operating voltage to 230 volt AC +/- 10%. Potable water system components shallcomply with Safe Drinking Water Act Amendments, the 1988 Lead ContaminationControl Act and shall be to ANSI/NSF 61 Section 9. Contractor shall require to submittest report post installtion of RO plant and cost shall be inclusive of 15 days training toengineer incharge.

each 4.00 0.00

MR-13 5.2

Supply, installation , testing & commissioning of high efficiency Storage water cooler /Dispenser of follwing capacities with water at 15°C cooled from 40°C inlet water at35°C ambient. Evaporator shall be high tank type and shall be encapsulated ininsulation. R-404 refrigerant system shall be hermetically sealed and refrigerant shallbe capillary tube controlled. An adjustable thermostat having an off position shallcontrol refrigeration system. Cabinet shall be galvanized steel. Potable water systemcomponents shall comply with Safe Drinking Water Act Amendments, the 1988 LeadContamination Control Act and shall be to ANSI/NSF 61 Section 9. chiller should besingle phase 220 V, 50 Hz, with cooling coil, heavy gauge galvanized steel complete asrequired including foundation, complete as required.

0.00

Cooling capacity : 40 lts/hr. And storage capacity 80 lts each 4.00 0.00SUB-TOTAL 0.00CHAPTER 1: FIRE PUMPS AND ALLIED ACCESORIES 0.00Supply, installation, testing and commissioning of electrically driven high pressurecentrifugal factory fitted fire hydrant / sprinkler pump, suitable for automaticoperation consisting of the following:

0.00

11 WAPCOS Ltd.Signature of Bidder

DSR No. SI.NO. DESCRIPTION UNIT QUANTITY RATE AMOUNT

MR-1 1.1

Electrical Driven Pump: Horizontal Spilt casing, centrifugal pump, suitable foroperation on 415 volts ± 6%, 3 phase, 50 HZ A.C supply. The installation shall becomplete with flexible coupling and coupling guard as required. Fire pump shall haveC.I. casing, CS diffusers, bronze impeller (hard finished and dynamically balanced) andS.S. (304) Shaft with mechanical seal, capable for delivering required capacity andhead to ensure a minimum pressure of 3.5 Kg/Sqcm at the farthest or topmosthydrant / sprinkler. The installation shall be complete with necessary pressure gaugewith gun metal shut off cock on delivery side. (The pump should be tested for benchmark at factory and shall be gotten approved by the Local fire Authority).

Pump shall be capable of furnishing not less than 150% of rated capacity at a head ofnot less than 65% of the rated head. The shut off head shall not exceed 120% of ratedhead.Squirrel cage induction motor, TEFC type suitable for operation on 415 volts, 3 phase50 HZ A.C supply, for the above pump with synchronous speed of 2900 RPM,conforming to IP 55 protection & class F insulation. The motor shall conform to IS 325-1978 (up to date) with flexible coupling and coupling guard, complete as required.Base Plate for Pump and motor to be common base plate of MS channel of requiredsize. The assembly to be mounted on spring isoltor assembly.Capacity : 2280 LPMHead : 70 mtr.

Set 1.00 0.00

MR-2 1.2

Diesel Driven Pump: Horizontal Spilt casing, centrifugal pump, suitable for operationon 415 volts ± 6%, 3 phase, 50 HZ A.C supply. The installation shall be completewith flexible coupling and coupling guard as required. Fire pump shall have C.I.casing, CS diffusers, bronze impeller (hard finished and dynamically balanced) andS.S. (304) Shaft with mechanical seal, capable for delivering required capacity andhead to ensure a minimum pressure of 3.5 Kg/Sqcm at the farthest or topmosthydrant / sprinkler. The installation shall be complete with necessary pressure gaugewith gun metal shut off cock on delivery side. (The pump should be tested for benchmark at factory and shall be gotten approved by the Local fire Authority).

12 WAPCOS Ltd.Signature of Bidder

DSR No. SI.NO. DESCRIPTION UNIT QUANTITY RATE AMOUNTPump shall be capable of furnishing not less than 150% of rated capacity at a head ofnot less than 65% of the rated head. The shut off head shall not exceed 120% of ratedhead.Heat exchanger cooled (secondary cooling) diesel engine of speed 1500 RPM suitablefor the above pump with automatic starting mechanism and other accessoriesincluding fuel tank (fabricated from 3mm MS sheet, painted with two coats ofsynthetic enamel paint over a coat of primer) of capacity adequate to sustain pumpoperation for 8 hours continuous working. The tank shall be fitted with Magnetic oillevel indicator, MH with cover, drain valve, air vent including structural supports(painted with approved shade), 2 Nos. x 12 volt battery, heat exchanger with necessarypiping connections & fittings, flexible coupling, coupling guard & exhaust pipeconnection complete as required.Base Plate for Pump and motor to be common base plate of MS channel of requiredsize. The assembly to be mounted on spring isoltor assembly.Capacity : 2280 LPMHead : 70 mtr.

Set 1.00 0.00

MR-3 1.3

Horizontal mono-block Pumps, suitable for operation on 415 volts ± 6%, 3 phase, 50HZ A.C supply. The installation shall be complete with Flexible coupling and couplingguard, complete as required. Jockey pump shall be of stainless steel construction. Thepump head and base shall be CI GG20 construction and impellers, diffusers, shaftsleeve, seal bush & pump shaft shall be in SS 304 material. The pump shall beprovided with mechanical seal The system shall be complete with necessary pressuregauge with gun metal shut off cock on delivery side (The pump should meet thecondition and shall be gotten approved by the Local fire Authority).Squirrel cage induction motor TEFC type for operation on 415 V, 3 phase 50 HZ ACsupply for the above pump with a synchronous speed of 2900 R.P.M. with flexiblecoupling and coupling guard etc. as required. Base Plate for Pump and motor to be common base plate of MS channel of requiredsize. The assembly to be mounted on spring isoltor assembly.Capacity : 180 LPMHead : 70 mtr.

Set 1.00 0.00

13 WAPCOS Ltd.Signature of Bidder

DSR No. SI.NO. DESCRIPTION UNIT QUANTITY RATE AMOUNT

MR-4 1.4

Horizontal mono-block Pumps, suitable for operation on 415 volts ± 6%, 3 phase, 50HZ A.C supply. The installation shall be complete with Flexible coupling and couplingguard, complete as required. Jockey pump shall be of stainless steel construction. Thepump head and base shall be CI GG20 construction and impellers, diffusers, shaftsleeve, seal bush & pump shaft shall be in SS 304 material. The pump shall beprovided with mechanical seal The system shall be complete with necessary pressuregauge with gun metal shut off cock on delivery side (The pump should meet thecondition and shall be gotten approved by the Local fire Authority).Squirrel cage induction motor TEFC type for operation on 415 V, 3 phase 50 HZ ACsupply for the above pump with a synchronous speed of 2900 R.P.M. with flexiblecoupling and coupling guard etc. as required. Base Plate for Pump and motor to be common base plate of MS channel of requiredsize. The assembly to be mounted on spring isoltor assembly.Capacity : 900 LPMHead : 35 mtr.

Set 1.00 0.00

MR-5 1.5

Providing & fixing MS Class ‘C’ diesel engine exhaust pipe (including all fittings, clamps,steel support) of 100mm dia for the engine. The pipe shall be insulated with 100 mmthick mineral wool insulation wrapped in chicken mesh and clad with 24 gaugealuminium sheet.

metre 45.00 0.00

MR-6 1.6

Providing, fixing, testing and commissioning of precharged air vessel conforming to IS2825 (size 450 mm dia & 2000 mm height cylinderical shell thickness not less than 6mm and dish thickness not less than 8 mm) for pressurization of hydrant / sprinklersystem complete with adequate pressure switches (as per design / requirement) withvalves to operate as per operating sequences including 25 mm dia drain valve, airrelease valve with stop cock on the top, 25 mm dia inlet with isolating valve dulypainted from inside and outside complete as required.

each 1.00 0.00

MR-7 1.7Providing, fixing, testing & commissioning of Air release valve with 15mm dia stopcock, flanged inlet connection, pressure gauge with gun metal stop cock complete withall accessories as required and conforming to IS IS : 12992 (Part 1).

each 1.00 0.00

14 WAPCOS Ltd.Signature of Bidder

DSR No. SI.NO. DESCRIPTION UNIT QUANTITY RATE AMOUNT

MR-8 1.8

Providing, fixing, testing and commissioning of Vortex inhibitors at suction line fromfire tank to prevent Air entrapment and its resultant choking effect on full flowdischarge and eliminating potential damage to booster pump equipment bypreventing initiation of vortices within a tank when the contained liquid is beingextracted and assists in maximizing effective tank capacity. the vortex plate shall beconstructed of SS 316 coupled on MS pipe of thickness not less than 6 mm. the itemincludes painting, bends, etc all as required.

each 2.00 0.00

SUB-TOTAL 0.00CHAPTER 2: INTERNAL HYDRANT

MR-9 2.1

Supplying, installation, testing and commissioning of Stainless steel Single Headedlanding valve with 75 mm nominal bore flanged inlet conforming to IS 1538(Part IV),Brass spindle controlled 63 mm diameter female instantaneous outlet with stainlesssteel coupling, Brass blank cap, chain, twist release type lug & all accessories necessaryto complete the arrangement. The entire assembly to be conforming to IS:5290-1993.The item includes fixing the assembly with anchor fastner, taking flanged tap off fromthe wet riser with glycerine filled pressure guage and forged brass balve valve (PN 16)with all required accesories including nuts, bolts, gaskets, painting etc complete in allrespect as per the satisfaction of the engineer in charge.

each 4.00 0.00

MR-10 2.2

Supplying, installation, testing and commissioning of swinging type First Aid hose reelconforming to IS:884-1985 with side plate powder coated red colour hose reel drum(LPCB approved) with 30 mts. long and 20 mm diameter heavy duty high pressurebraided Rubber water hose conforming to IS 444 Type, 25 mm dia Ball valve,termination with Gun metal coupling, 6mm outlet Bronze nozzle with shut off valveconfirming to IS 8090 - 1976 complete with MS socket for tap-off from the the wetriser connecting the landing valve(tap off to be after the position of pressure guagetowards landing valve), drum and brackets (including painting as per the specification)for fixing on wall with anchor fastner, bolts & nuts etc complete in all respect as perthe satisfaction of the engineer in charge.

each 4.00 0.00

15 WAPCOS Ltd.Signature of Bidder

DSR No. SI.NO. DESCRIPTION UNIT QUANTITY RATE AMOUNT

MR-11 2.3

Supplying, installation, testing and commissioning of rubber reinforced lined fire hosepipe (Conforming to IS : 636-1988) Type-B of 63 mm dia and length of 15 mtr. The hoseshall be rated for a brust pressure of 35.7 Kg/sqcm. The hydrostatic proof pressure testfor the hose to be in accordance with IS 445-1975. Hose shall be complete with ISImarked brass male & female coupling (IS:903-1993) bound & rivetted to hose pipewith copper rivets & 1.5 mm copper wire etc complete in all respect as per thesatisfaction of the engineer in charge. (Location : Internal fire hydrant)

each 8.00 0.00

MR-12 2.4

Supplying, installation, testing and commissioning of 63 mm diameter Stainless steel304 instantaneous pattern short branch pipe conforming to IS 903-1993 with 19 mmdiameter outlet, suitable for inter connection to hose pipe coupling complete in allrespect as per the satisfaction of the engineer in charge.

each 4.00 0.00

MR-13 2.5Supplying and installation of standard fireman's axe conforming to IS 926-1985 withinsulated chequered vulcanized rubber handle. The Axe to be mounted on the wallwith suitable holder and fastened on the wall such that it is visible at all angles.

each 4.00 0.00

MR-14 2.6

Supplying and installation of 5 mm thick glass door with locking arrangement (with 16gauge Mild Steel frame) of size 2100mm x 1200mm with center opening for fire hosecabinet. The term "FIRE HOSE CABINET" to be painted on the glass with minimumheight of letter to be 75mm and width 12mm. The cabinet frame shall be painted withone coat of primer and two or more coats of synthetic enamel paint of approvedshade or as required in consultation and approval of the engineer in charge.

each 4.00 0.00

MR-15 2.7

Supplying, installation, testing and commissioning of Mild Steel Air cushion tank on topof each riser/downcomer fabricated from 6mm thick heavy duty type C Mild steelplate or pipe for the shell, 8mm thick heavy duty type C Mild steel plate for the dishend, 250 mm in diameter and 1.2 m in height with supporting structure fabricatedfrom 40x40x5mm angle frame with 25 mm diameter Air release valve at the top & 25mm diameter stop cock at the bottom with flanged inlet connections with allaccessories as required. The Vessel shall be painted with one coat of primer and two ormore coats of synthetic enamel paint of approved shade or as required in consultationand approval of the engineer in charge. The Air cushion tank shall be rated towithstand the working pressure and a minimum of 10 bar pressure requirement.

each 2.00 0.00

SUB-TOTAL 0.00CHAPTER 3: PIPING, VALVES AND ALLIED

16 WAPCOS Ltd.Signature of Bidder

DSR No. SI.NO. DESCRIPTION UNIT QUANTITY RATE AMOUNTMR-16 3.1 Supplying, laying, jointing, testing and commissioning of following sizes of pipes

conforming to IS-1239 with all accessories like fittings (for pipes upto 50mm dia Socketwelded fittings and for pipes above 80 mm dia MS fitting with welded joint shall beused) including tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts,washer etc. and all associated fittings as required. The item is inclusive ofsupporting/fixing the pipe on floor/wall/ceiling with clamps, hangers (using anchorfastners) as per specification, drawings and as per the approval from the engineer incharge. The pipes to be provided with two or more coats of synthetic enamel paint ofapproved shade over two coats of primer. Prior to application of primer the surfaceshould be cleaned for any dirt, rusts, rough substance etc.. Painting of flow directionsand legends as per the approval of the Engineer in charge.GI pipe sleeve of suitable higher size shall be provided wherever the pipes are crossingthe walls / floors and sealing the sleeves with glass wool in between & fire sealentcompound at either end all as per the engineer in charge's requirement. The scopeincludes cutting holes and chases in brick, RCC work and making good the same tooriginal conditions complete in all respects as required by the engineer in charge.

All hangers, clamps, brackets etc. shall be of galvanized iron unless specified otherwiseand the supply of the same shall also be included in rates under this head. Welding ofany kind on the galvanized support / hanger shall not be permitted. Wherever clubbedpipe work is running, a combined support will be permitted as per the specificationsand as per the detailed drawings shared with the contractor. The pipe supportsworked with Mild steel material shall be coated with atleast 2 coats of primer followedby 2 coats of the same enamel paint as the pipe.MS `C' Heavy class pipe

3.1.1 25 mm diameter metre 10.00 0.003.1.2 65 mm diameter metre 8.00 0.003.1.3 80 mm diameter metre 20.00 0.003.1.4 100 mm diameter metre 45.00 0.003.1.5 150 mm diameter metre 150.00 0.003.1.6 200 mm diameter metre 35.00 0.00

17 WAPCOS Ltd.Signature of Bidder

DSR No. SI.NO. DESCRIPTION UNIT QUANTITY RATE AMOUNTMR-17 3.2 Supplying, laying, jointing, testing and commissioning of following sizes of pipes

conforming to IS-1239 with all accessories like fittings (for pipes upto 50mm dia Socketwelded fittings and for pipes above 80 mm dia MS fitting with welded joint shall beused) including tees, elbows, reducers, union, flanges, rubber gaskets, GI nuts bolts,washer etc. and all associated fittings as required. The item is inclusive ofsupporting/fixing the pipe on floor/wall/ceiling with clamps, hangers (using anchorfastners) as per specification, drawings and as per the approval from the engineer incharge. The pipes to be provided with two or more coats of synthetic enamel paint ofapproved shade over two coats of primer. Prior to application of primer the surfaceshould be cleaned for any dirt, rusts, rough substance etc.. Painting of flow directionsand legends as per the approval of the Engineer in charge.Wherever the pipes running below ground shall not be less than 1.0 m below groundlevel at any point. Pipes shall embedded all round 150 mm thick compacted silversand and protection to GI pipes and fitting by applying pypkote primer @ 100gm/sqm). Thereafter wrapping 4 mm thick pypkote (AW4mm) protection coating bythermo fusion process. Overlap shall be maintained at 20 mm. The application shall bestrictly as per manufacturers’ specifications.MS `C' Heavy class pipe (For External Hydrant and Sprinkler Piping)

3.2.1 100 mm diameter metre 25.00 0.003.2.2 150 mm diameter metre 65.00 0.00

MR-18

3.3 Supplying, fixing, testing and commisioning of female screwed end Full bore leveroperated Forged brass ball valve(PN 16) having forged brass stem, carbon steel nut,carbon steel washer, carbon steel lever, forged brass body and gland nut, PTFE glandpacking and body seat ring, forged brass bonnet and ball with (threaded joints)complete as required with nuts, bolts, gaskets, washers, plastic sleeve over handleetc.. The body of the valve to be tested to a pressure of 24 Kg / sqcm and seat pressureto be 17.6 kg/sqcm for metal seated valves.

3.3.1 25 mm nominal bore each 5.00 0.003.3.2 32 mm nominal bore each 2.00 0.003.3.3 40 mm nominal bore each 2.00 0.003.3.4 50 mm nominal bore each 2.00 0.00

18 WAPCOS Ltd.Signature of Bidder

DSR No. SI.NO. DESCRIPTION UNIT QUANTITY RATE AMOUNT

MR-19

3.4 Supplying, fixing, testing and commisioning of butterfly valve (PN 16) conforming to IS:13095 with Grey cast iron Body, Carbon steel flow control lever, Stainless steel (AISI304), EPDM HT Lining, Stainless steel (AISI 304) Disc, Bronze Stem bush, Nitrile rubber'O' Ring and Neoprene body lining. The valves above 150mm nominal bore to be Gearoperated and below and equal to 150mm nominal bore to be Flow control leveroperated. The valve shall be compatible to be installed between flanges as per BS 10relevant tables. The cost of the valves to be inclusive of flanges on either ends withrubber gaskets, nuts, washers etc. complete as required as per the satisfaction of theengineer in charge. The body of the valve to be tested to a pressure of 24 Kg / sqcmand seat pressure to be 17.6 kg/sqcm. All valves shall be provided with Pad lockarrangement with lock and key. 4 set of keys to be provided.

3.4.1 65 mm nominal bore (Lever operated) each 5.00 0.003.4.2 80 mm nominal bore (Lever operated) each 5.00 0.003.4.3 100 mm nominal bore (Lever operated) each 8.00 0.003.4.4 150 mm nominal bore (Lever operated) each 10.00 0.003.4.5 200 mm nominal bore (Gear Operated) each 2.00 0.00

MR-20

3.5 Supplying, installation, testing and commissioning of Dial type pressure gaugeconforming to IS 3624:1987 with 150 mm diameter Gylcerine filled dial casing isolatedthrough a forged brass ball valve from the piping including short piece, nipples, elbowsetc as required to complete the installation. The pressure guage shall be suitable forrating between 0 to 20 bar with no Syphon.

each 8.00 0.00

MR-21

3.6 Supplying, installation, testing and commissioning of Dual plate Wafer type Checkvalve (PN 16) with Grey cast iron Body, stainless steel (AISI 304) Flap, AISI 304 pinwasher and spring, EPDM Body ring and carbon steel retainer hook. The valve shall becompatible to be installed between flanges as per BS 10 relevant tables. The cost ofthe valves to be inclusive of flanges on either ends with rubber gaskets, nuts, washersetc. complete as required as per the satisfaction of the engineer in charge. The body ofthe valve to be tested to a pressure of 24 Kg / sqcm and seat pressure to be 17.6kg/sqcm.

3.6.1 65 mm nominal bore each 1.00 0.003.6.2 150 mm nominal bore each 4.00 0.00

19 WAPCOS Ltd.Signature of Bidder

DSR No. SI.NO. DESCRIPTION UNIT QUANTITY RATE AMOUNT

MR-22

3.7 Supplying, installation, testing and commissioning of Cast Iron Y-Type Strainer (PN 16)with Cast iron Body and Cover, stainless steel (AISI 304) screen with 1-3mmperforation, Rubber gasket and carbon steel Stud and nut. The strainer shall becompatible to be installed between flanges as per BS 10 table F. The cost of the valvesto be inclusive of flanges on either ends with rubber gaskets, nuts, washers etc.complete as required as per the satisfaction of the engineer in charge. The body of theStrainer to be tested to a pressure of 24 Kg / sqcm.

3.7.1 80 mm nominal bore each 1.00 0.003.7.2 200 mm nominal bore each 4.00 0.00

MR-23

3.8 Supplying, installation, testing and commissioning of Sluice valve (PN 16) conformingto IS 14846 with Grey cast iron Body and Bonnet, Brass stem, carbon steel nut andbolt,Cast iron handwheel and gland and thrust plate, Rubber gasket and gland packing.The valve shall be compatible to be installed between flanges as per BS 10 relevanttables. The cost of the valves to be inclusive of flanges (conforming to IS-1538) oneither ends with rubber gaskets, nuts, washers etc. complete as required as per thesatisfaction of the engineer in charge. The body of the valve to be tested to a pressureof 24 Kg / sqcm and seat pressure to be 17.6 kg/sqcm.

3.8.1 200 mm nominal bore each 2.00 0.00

MR-24

3.9 Supplying, installation, testing and commissioning of Heavy Duty floating flange typeexpansion joints (PN 16) conforming to FSA and EJMA(USA) with EPDM Body and zinccoated mild steel flanges. The bellow shall be compatible to be installed betweenflanges as per BS 10 relevant tables, ANSI 16.5 Class 125/150 BS4504/DN2501 . Thecost of the valves to be inclusive of flanges on either ends with rubber gaskets, nuts,washers etc. complete as required as per the satisfaction of the engineer in charge.The body of the valve to be tested to a pressure of 24 Kg / sqcm.

3.9.1 65 mm nominal bore each 1.00 0.003.9.2 80 mm nominal bore each 1.00 0.003.9.3 150 mm nominal bore each 6.00 0.003.9.4 200 mm nominal bore each 2.00 0.00

20 WAPCOS Ltd.Signature of Bidder

DSR No. SI.NO. DESCRIPTION UNIT QUANTITY RATE AMOUNT

MR-25

3.10 Supplying, installation, testing and commissioning of Spring Loaded Air relief valve (PN16) conforming to IS 12992 with Cast carbon steel body, carbon steel spring, AISI 304Stem,nuts and bolts and EPDM Seal with flanged inlet connections (conforming to IS6392), Bourden type gylcerine filled 150 mm diameter pressure gauge, washer etccomplete as required. as per the satisfaction of the engineer in charge. The body of thevalve to be tested to a pressure of 24 Kg / sqcm.

each 1.00 0.00

SUB-TOTAL 0.00CHAPTER 4: EXTERNAL HYDRANT

MR-26 4.1

Providing and fixing of SS fire brigade 4-way connection (suction collecting head)consisting of 4 No. 63 mm dia instantaneous type male couplings with built-in swingcheck valves, 1 No. 150 mm dia Butterfly valve, 1 No. 150 mm dia non-return valve and150 mm dia flanged outlet complete with bolts, nuts and rubber insertions as required.

each 2.00 0.00

MR-27 4.2

Providing and fixing of SS fire brigade suction hose coupling (draw-out connection)with nut for female coupling complete with 100 mm dia GI suction pipe and 100 mmdia foot valve (to be connected to static tank). Provision of GI drop pipe and foot valveshall be made in all the fire water static storage tanks (4 No) (GI pipe to be paidseparately through appropriate item while cost of foot valve to be included).

each 1.00 0.00

MR-28 4.3

Providing & fixing MS cabinet (to enclose above FB connection and draw-outconnection ) fabricated from 16g MS sheet with full front glass door and lockingarrangement duly painted with one coat of primer and two or more coats of stoveenamel paint of approved make and shade and suitably mounted on a raised masonryplatform as required (Approx 0.6m x 0.6m x 0.45m)

each 3.00 0.00

SUB-TOTAL 0.00CHAPTER 5: FIRE EXTINGUISHERSupply, installation, testing and commissioning of following types of extinguisher withprovision of wall bracket (fixed with anchor fastner).

MR-29 5.1

Providing & fixing ISI marked portable chemical fire extinguisher, water (gas pressure)type capacity 9 litres conforming to IS: 2878 with gun metal cap and nozzle andcomplete in all respects including initial fill and wall suspension brackets.

each 4.00 0.00

21 WAPCOS Ltd.Signature of Bidder

DSR No. SI.NO. DESCRIPTION UNIT QUANTITY RATE AMOUNT

MR-30 5.2

Providing & fixing ISI marked (IS:2878) portable CO2 type fire extinguisher type 4.5 kgcapacity. Including valve, discharge hose of not less than 10 mm dia & 1 M longcomplete in all respects including initial filled with CO2 gas confirming to IS:307-1966& filled to a filling rate of not more than 0.667 and wall suspension bracket.

each 4.00 0.00

MR-31 5.3

Providing & fixing of ABC Type, Portable Fire Extinguisher, dry powder type (GasCartridge) conforming to IS: 15683 : 2006 with cylinder initially fully charged with drypowder, ISI marked confirming to IS:15683 : 2006 complete with standard dischargevalve with tube, CI bracket for wall mounting.

5.3.1 4 Kg each 4.00 0.005.3.2 10 Kg each 1.00 0.00

MR-32 5.4

Mechanical Foam type Fire Extinguisher. In HP Mild Steel Cylinders ISI marked /approved fitted with pressure indicating gauge, internal tube, squeeze lever type valvefully charged complete in all respects including wall suspension bracket / trolleymounted and conforming to IS:910.

5.4.1 9 Litres each 1.00 0.005.4.2 50 Litres (trolley mounted) each 1.00 0.00

MR-33 5.5

Supplying and installing at approved location approved make fire buckets of 24 gaugegalvanized steel sheet confoming to IS: 2546, standard 9 litre capacity and of roundbottom shape, painted white inside and red outside and black on the bottom,inscribed with letters “FIRE” in black and gold. Cost shall be inclusive of providing MSstand duly painted over a coat of primer.

each 4.00 0.00

SUB-TOTAL 0.00

22 WAPCOS Ltd.Signature of Bidder

SR.NO DESCRIPTION AMOUNT1 CHAPTER 1: VRV CONDENSING UNIT 0.00

2 CHAPTER 2: AIR HANDLING UNIT 0.00

3 CHAPTER 3: AIR DISTRIBUTION PRODUCT 0.00

4 CHAPTER 4: INSULATION & ACOUSTIC 0.00

5 CHAPTER 5: VENTILATION SYSTEM 0.00

0.00TOTAL

PROJECT - CONSTRUCTION OF MULTIPURPOSE INDOOR HALL AT KALINGA SPORTS COMPLEX,BHUBANESWAR, ODISHA

SUMMARY (MECHANICAL WORKS)

WAPCOS Ltd.Signature of Bidder

DSR-2018 S.NO. DESCRIPTION UNIT QUANTITY RATE AMOUNT1 CHAPTER 1: VRV CONDENSING UNIT

MR-1 1.1 VARIABLE REFRIGERANT FLOW/VOLUME SYSTEMSupply, Installation, testing and commisioning of variable refrigerant flow/Volumemodular type air conditioning system with Inverter Scroll Compressor suitable for 415±10% for outdoor application complete with out door units ,controllers, accessoriesincluding fully charged with refrigerant R410A to outdoor unit and all runningrefrigerant pipe as per detail given in specifications & Drawings for the followingconfigurations. It shall include anti vibration isolator pad for outdoors unit.TheOutdoor unit shall be placed on RCC Foundation with vibration isolator pad. The unitshall be complete in all respect and should match the specification , Drawings andSchedule.The quoted price shall be inclusive of refnut required to connect the outdoorunit.The COP of the unit shall not be less than 3.10 @100 Loading condition calculatedat ambient temperature of Odisha.

Outdoor Units - Cooling Only Type1.1.1 60 HP No. 2 01.1.2 20 HP No. 2 0

MR-2 1.2 INDOOR UNITSITC, Loading, Unloading of the indoor unit. Unit shall be complete in all respect andsuitable for 230 ±5% volts include wired thermostat having a dispay showingtemperature and control of temperature inside the room. The Quoted Price shallinclude hanging arrangemnt of the unit with necessary supporting rod, nut &bolts,fastners and accessories for complete installation of Indoor unit. User shall beable to adjust the temperature as per their comfort level requirement.Ceiling Suspended Cassette Unit with Drain Pump

1.2.1 Cassette unit : 1.28 TR No. 3 01.2.2 Cassette unit : 1.59 TR No. 2 01.2.3 Cassette unit : 2.01 TR No. 3 01.2.4 Cassette unit : 3.00 TR No. 2 01.2.5 Ductable unit : 4.55 TR No. 3 0

MR-3 1.3 REFNUT/Y-JOINT Supply,Instllation,testing and comissioning of Y-joints and headers etc. No. 12 0

MR-4 1.4 REFRIGERANT PIPINGSupply, fabrication, installation, testing of Interconnecting refrigerant copper pipe

work with closed cell nitrile rubber tubular insulation between each set of indoor &

outdoor units as per specifications, all piping inside the room shall be properly

supported with MS hanger/tie rod .Refer tender specification for detail description1.4.1 41.3 mm O.D (wall Thickness-1.4 mm) (Insulation: 19 mm) metre 60 01.4.2 34.9 mm O.D (wall Thickness-1.2 mm) (Insulation: 19 mm) metre 60 01.4.3 28.6 mm O.D (wall Thickness-1.0 mm) (insulation : 19 mm) metre 80 01.4.4 22.2 mm O.D (wall Thickness-1.0 mm) (insulation : 19 mm) metre 80 01.4.5 19.1 mm O.D (wall Thickness-1.0 mm) (insulation : 19 mm) metre 60 01.4.6 15.9 mm O.D (wall Thickness-1.0 mm) (insulation : 19 mm) metre 60 01.4.7 12.7 mm O.D (wall Thickness-0.8 mm) (insulation : 13 mm) metre 40 01.4.8 9.5 mm O.D (wall Thickness-0.8 mm) (insulation : 13 mm) metre 60 0

MR-5 1.5 CONDENSATE DRAIN PIPINGSupply, installation, testing and commissioning of Rigid heavy class uPVC piping withminimum 6 mm nitrile rubber insulation over the pipes ,complete with fittings,supports,U trap arrangement ,clean plug and accessories for units as perspecifications and technical specification.

1.5.1 25 mm dia metre 40 01.5.2 40 mm dia metre 40 01.5.3 50 mm dia metre 40 0

4.6 1.6 CABLE TRAY FOR REFRIGERANT PIPING

PROJECT - CONSTRUCTION OF MULTIPURPOSE INDOOR HALL AT KALINGA SPORTS COMPLEX, BHUBANESWAR, ODISHABILL OF QUANTITIES (MECHANICAL WORKS)

WAPCOS Ltd.Signature of Bidder

DSR-2018 S.NO. DESCRIPTION UNIT QUANTITY RATE AMOUNTSupplying and installing of following size of perforated hot dip Galvanised GI cabletray with perforations not more than 17.5%, in convenient sections, joined withconnectors, suspended from ceiling with G.I suspenders including bolts and nuts, etc.for carrying refrigerant pipe in outdoor application as required.

4.6.10 1.6.1 450 mm width x 62.5 mm depth x 1.6 mm thickness metre 40 0SUB-TOTAL 0CHAPTER 2: AIR HANDLING UNIT

MR-6 2.1 FLOOR MOUNTED AIR HANDLING UNITSupply , Installation , testing and commissioning of factory built floor mounted DoubleSkinned DX Type air-handling unit Horizontal/Vertical type with thermal break profilefabricated out of extruded aluminium section with 0.8mm pre-plasticized GI sheetoutside & 0.8mm GI Sheet inside, blower section with AMCA certified DIDW BackwardCurve blower/Plug Fan having airfoil blade (Suitable static pressure as required ,minimum 2 bend GSS/ PVC eliminators ) and blower motor TEFC type with IE-3 Classrating suitable for operation on 415 volts ± 10% , 50 Hz ± 5% AC supply , 6 Row coolingcoil or selected for off coil temperature of 11.5 °C made of Aluminium finned Coppertube( Tube thickness not less than 0.40 mm) with coil section , thermostat , pre-filtersection with non wovensynthetic media down to 10 micron particle size with anefficiency of 90% , fine filter section down to 5 micron particle size with an efficiencyof 99% ,polished stainless steel drain pan made out of 18 G sheet duly insulatedcomplete with motor and belt drive package. The AHU shall be complete in allrespect and drain piping as per the specification to be provided to the closest floordrain.The cost should include 150 mm dia dial type pressure gauges ( 2 nos.) and industrialtype thermometer ( 2 nos.) at the inlet and outlet of each type of coil , auto purgevalve wherever required, Mixing chamber with return air and fresh air damper ,necessary vibration isolation arrangement etc. complete as per specification anddrawingsThe AHU panels shall be insulated with 46±2 mm thick & 40 Kg/m³ density PU foam.The motor & blower assembly shall be mounted on Aluminium extruded sectiononly. The complete AHU shall confirm to standard specification. The face velocityacross cooling coil shall be limited to 400 FPM maximum. The capacity of Air-handlersshall be as follows:Total Static pressure given below is minimum required for the system. Actual staticpressure shall be calculated & confirmed by the vendor at time of Bidding.The unit shall have Eurovent certification.

2.1.1TAG- AHU -1: 10000 CFM/ 24 TR, 75 mm SP with Mixing Box

Each 4 0

MR-7 2.1.2 Supply, installation, tesing and commissioning of expansion and control kit for theoperation of AHU's.

Each 4 0

SUB-TOTAL 0CHAPTER 3: AIR DISTRIBUTION PRODUCT

16.12.1 3.1 GSS DUCT (FACTORY FABRICATED)- RoundSupply, installation, balancing and commissioning of factory fabricated GSS sheetmetal rectangular/Round ducting complete with neoprene rubbergasket,elbow,spliter damper,vanes,hangers,supports etc as per approved drawingsand specification of followi ng sheet thickness complete as required.

16.12.1.1 3.1.1 24 G (0.63 mm) Sqm 420 016.12.1.2 3.1.2 22 G (0.80 mm) Sqm 280 016.12.2 3.2 GSS DUCT (SITE FABRICATED)

Supply, installation, balancing and commissioning of fabricated at site GSS sheetmetal rectangular/Round ducting complete with neoprene rubbergasket,elbow,spliter damper,vanes,hangers,supports etc as per approved drawingsand specification of followi ng sheet thickness complete as required.

16.12.2.1 3.2.1 24 G (0.63 mm) Sqm 120 016.12.2.2 3.2.2 22 G (0.80 mm) Sqm 40 0

16.13 3.3 VOLUME CONTROL DAMPER

WAPCOS Ltd.Signature of Bidder

DSR-2018 S.NO. DESCRIPTION UNIT QUANTITY RATE AMOUNTSupplying, installing, testing & commissioning of GI volume control damper with

minimum 1.6 mm flange and 1.8 mm blade thickness within ducts to be provided

with suitable links, levers and quadrants for manual control of volume of air flow and

for proper balancing of the air distribution system as per schedules & drawings.

Sqm 4 0

16.15 3.4 SUPPLY AIR GRILLSupply, installation, testing,balancing and fixing of Powder coated aluminiumextruded grill with aluminium construction collar damper for supply air as perspecification & the sizes will be as per schedules and drawing.Refer technicalspecification for detail description

Sqm 10 0

16.16 3.5 RETURN AIR GRILLSupply, installation, testing ,balancing and fixing of Powder coated aluminiumextruded grill for return air as per specification & the sizes will be as per schedulesand drawing.Refer technical specification for detail description

Sqm 10 0

16.17 3.6 SUPPLY AIR DIFFUSERSupply, installation, testing,balancing and fixing of Powder coated aluminiumextruded grill with collar damper for supply air as per specification & the sizes willbe as per schedules and drawing.Refer technical specification for detail description Sqm 1 0

16.18 3.7 RETURN AIR DIFFUSERSupply, installation, testing ,balancing and fixing of Powder coated aluminiumextruded grill for return air as per specification & the sizes will be as per schedulesand drawing.Refer technical specification for detail description

Sqm 1 0

MR-8 3.80 EXHAUST AIR GRILLSupplying, Installing, testing and commissioning of powder coated extrudedaluminium exhaust air grille with min.60 % free area, with metallic frame work &fixing accessories, to be fixed on external wall to exhaust air from basement area toambient , it shall be suitable for exhausting required air in CFM . Louvers need to besuitable in order avoid rain water entry in to basement @ 15 degree deflection withbird screen complete as per specification approved drawings and schedules.

Sqm 4 0

MR-9 3.10 FRESH/EXHAUST AIR LOUVRESupplying, installing, testing and commissioning of GI construction fresh/exhaust airlouvers with min. 60 % free area, bird screen and painted in baked enamel shade asper clients or architect approval with metallic frame work complete as perspecification approved drawings and schedules.

Sqm 10 0

16.2 3.11 FIRE DAMPERSupplying, Fixing,testing and commissioning of fire damper in supply air duct/mainbranch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in theevent of power failure automatically and open the same in case of power beingrestored. The spring return action shall be inbuilt mechanism and not externallymounted. the damper shall also be closed in the event of fire signal complete asrequired adn as per specifications.

16.20.1 3.13.1 Fire damper Sqm 3 016.20.2 3.13.2 Actuator No. 4 0

SUB-TOTAL 04 CHAPTER 4: INSULATION & ACOUSTIC

16.23 4.1 DUCT INSULATIONSupplying and fixing of following thickness duly laminated aluminium foil of mat finishclosed cell nitrile rubber (Class "O")insulation on existing duct after applying suitableadhesive for Nitrile rubber. The Joint shall be sealed with 50 mm wide and 3 mm thickself adhesive nitrile rubber tape insulation complete as per specification and asrequired.

16.23.1 4.1.1 19 mm on supply duct Sqm 720 0DUCT ACOUSTIC

WAPCOS Ltd.Signature of Bidder

DSR-2018 S.NO. DESCRIPTION UNIT QUANTITY RATE AMOUNTSupply and fixing of acoustic lining of supply air duct and plenum with 25 mm thickresin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of1.25 mm thick, at 600mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thickperforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts,bolts, stick pins, CPRX compound etc. complete as required and as per specifications.

Sqm 80 0

MR-10 4.2 DOUBLE LAYER CANVAS CONNECTIONSupply,Installation,testing and commissioning of double Layer canvas connection fireretardant cloth for the end connection of AHU/CSU/Ventilation fan to reduce thevibration.It shall be fire rated for atleat 2 hrs.Refer tender specification for detaildescription

Sqm 4 0

SUB-TOTAL 05 CHAPTER 5: VENTILATION SYSTEM

MR-11 5.1 TUBE AXIAL FLOW FAN FOR SMOKE EVACUATIONSupply, installation, testing and commissioning of Fire Rated Tube Axial flow fanscomplete with tube casing, impeller, bird screen, gravity louvers, necessary nut bolts,necessary transition piece and canvas connection for proper installing, directlycoupled to TEFC Sq.cage, EFF-1 High efficiency induction motor Class"H" insulationmounted on vibration isolators suitable for 415V±10%, 50 Hz. 3 phase electric supplycomplete as per the technical specifications enclosed. The fans should be AMCAcertified for air performance. The fan should be rated for a minimum of 250 Deg C fora minimum of 2 Hrs. application.The fan shall be complete in all respect and shouldmatch the specification ,Drawings and Schedule..The quoted price shall consist ofmounting arrangemnt along with spring isolator for fan.

Note:Noise level should be selected for 3 meter distance from fan at roomcondition.For Emergency case - 80db(A)@3m

5.1.1 12000 CFM ,Total static pressure of 20 MM WG No. 4 0MR-12 5.2 INLINE FAN

Supply , installation , testing and commissoning , of duct mounted inline fanscomplete with direct driven centrifugal fan , TEFC squirrel cage induction motor , withefficiency class IE-3 , direct drive arrangement , heavy gauge sheet metal casing ,rubber isolator mounts and other accessories.The fan shall be complete in all respectand should match the specification ,Drawings and Schedule. Inline fans shall be offollowing capacities.

5.2.1 600 CFM Total static pressure of 10 mm WG No. 4 05.2.2 200 CFM Total static pressure of 5 mm WG No. 3 0

SUB-TOTAL 0

WAPCOS Ltd.Signature of Bidder