12
© Siemens AG 2008 - Subject to modifications WinCC Competence Center Mannheim 2008-04-30 Slide 1 Process Management System Economical Automation with Standard Software CONTACT PM-OPEN PM-MAINT PM-ANALYZE PM-QUALITY PM-CONTROL

© Siemens AG 2008 - Subject to modifications WinCC Competence Center Mannheim 2008-04-30Slide 1 Process Management System Economical Automation with Standard

Embed Size (px)

Citation preview

Page 1: © Siemens AG 2008 - Subject to modifications WinCC Competence Center Mannheim 2008-04-30Slide 1 Process Management System Economical Automation with Standard

© Siemens AG 2008 - Subject to modifications

WinCC Competence Center Mannheim2008-04-30 Slide 1

Process Management SystemEconomical Automation with Standard Software

CONTACT

PM-OPEN

PM-MAINT

PM-ANALYZE

PM-QUALITY

PM-CONTROL

Page 2: © Siemens AG 2008 - Subject to modifications WinCC Competence Center Mannheim 2008-04-30Slide 1 Process Management System Economical Automation with Standard

© Siemens AG 2008 - Subject to modifications

WinCC Competence Center Mannheim2008-04-30 Slide 2

PM-CONTROL

PM-CONTROL

PM-QUALITY

PM-QUALITY

PM-MAINT

PM-MAINT

PM-ANALYZE

PM-ANALYZE

PM-OPEN

PM-OPEN

Main

tenan

ceD

iagn

ostics

Pro

du

ction

- Qu

ality

System

integ

ration

The intelligent Maintenance

Management System

Recipe/Product Data Management,Job Control for industrial processand production plants

Job/Batch-Oriented Archiving andReporting for process data, alarms and laboratory data

Analysis of Alarm and Process Data

(error message statistics, downtime frequency,

analysis of weak points)

Overview of Process Management System

Communication solutions(online computer link,

exporting process data,alarms and archive data,

connection to PI and SAP R/3)

PM-QUALITY

PM-CONTROL

PM-MAINT

PM-ANALYZE

CONTACT

HOSTS/S

PI

IMPORT

EXPORT

TCP/IP

PM-OPEN

Page 3: © Siemens AG 2008 - Subject to modifications WinCC Competence Center Mannheim 2008-04-30Slide 1 Process Management System Economical Automation with Standard

© Siemens AG 2008 - Subject to modifications

WinCC Competence Center Mannheim2008-04-30 Slide 3

Standard Products - The Key to Success

Use of standard software No development or updating costs Safe investment Immediate availability

Can be customized

Products can be integrated in WinCC / WinCC flexible / PCS7 Tested functionality Minimum training and/or engineering time

Excellent cost-effectiveness

Perfect Support

PM-QUALITY

PM-CONTROL

PM-MAINT

PM-ANALYZE

CONTACT

HOSTS/S

PI

IMPORT

EXPORT

TCP/IP

PM-OPEN

Page 4: © Siemens AG 2008 - Subject to modifications WinCC Competence Center Mannheim 2008-04-30Slide 1 Process Management System Economical Automation with Standard

© Siemens AG 2008 - Subject to modifications

WinCC Competence Center Mannheim2008-04-30 Slide 4

PM-OPEN EXPORT

Export of process data

Export of process and

archive data in text files Flexible, individual layout

of target file Export to any storage

medium (local / network) Dynamic generation of file names

TagLogging

TagLogging

AlarmLogging

AlarmLogging

GraphicsGraphics

PM-OPEN

EXPORT

PM-OPEN

EXPORT

PM-QUALITY

PM-CONTROL

PM-MAINT

PM-ANALYZE

CONTACT

HOSTS/S

PI

IMPORT

EXPORT

TCP/IP

PM-OPEN

Page 5: © Siemens AG 2008 - Subject to modifications WinCC Competence Center Mannheim 2008-04-30Slide 1 Process Management System Economical Automation with Standard

© Siemens AG 2008 - Subject to modifications

WinCC Competence Center Mannheim2008-04-30 Slide 5

New Features V 7

Support of WinCC Version 7

Support of Windows Vista

Export of new message blocks

Export of the last value by using the export type „Process value archive – table”

Data cache for User Archive data

Dynamic selection of a period with PM-OPEN EXPORT ActiveX

Increasing the performance by exporting message data

PM-QUALITY

PM-CONTROL

PM-MAINT

PM-ANALYZE

CONTACT

HOSTS/S

PI

IMPORT

EXPORT

TCP/IP

PM-OPEN

Page 6: © Siemens AG 2008 - Subject to modifications WinCC Competence Center Mannheim 2008-04-30Slide 1 Process Management System Economical Automation with Standard

© Siemens AG 2008 - Subject to modifications

WinCC Competence Center Mannheim2008-04-30 Slide 6

Support of WinCC Version 7

PM-OPEN EXPORT V7 is released for WinCC V7PM-QUALITY

PM-CONTROL

PM-MAINT

PM-ANALYZE

CONTACT

HOSTS/S

PI

IMPORT

EXPORT

TCP/IP

PM-OPEN

Page 7: © Siemens AG 2008 - Subject to modifications WinCC Competence Center Mannheim 2008-04-30Slide 1 Process Management System Economical Automation with Standard

© Siemens AG 2008 - Subject to modifications

WinCC Competence Center Mannheim2008-04-30 Slide 7

Support of Windows Vista

PM-OPEN EXPORT V7 is released for Windows Vista

Ultimate Edition

Enterprise Edition

Business Edition

PM-QUALITY

PM-CONTROL

PM-MAINT

PM-ANALYZE

CONTACT

HOSTS/S

PI

IMPORT

EXPORT

TCP/IP

PM-OPEN

Page 8: © Siemens AG 2008 - Subject to modifications WinCC Competence Center Mannheim 2008-04-30Slide 1 Process Management System Economical Automation with Standard

© Siemens AG 2008 - Subject to modifications

WinCC Competence Center Mannheim2008-04-30 Slide 8

Export of new message blocks

Export of new message blocks

Tag

User

Computer name

Priority

Flag

PM-QUALITY

PM-CONTROL

PM-MAINT

PM-ANALYZE

CONTACT

HOSTS/S

PI

IMPORT

EXPORT

TCP/IP

PM-OPEN

Page 9: © Siemens AG 2008 - Subject to modifications WinCC Competence Center Mannheim 2008-04-30Slide 1 Process Management System Economical Automation with Standard

© Siemens AG 2008 - Subject to modifications

WinCC Competence Center Mannheim2008-04-30 Slide 9

Export of the last value by using the export type „Process value archive – table”

PM-QUALITY

PM-CONTROL

PM-MAINT

PM-ANALYZE

CONTACT

HOSTS/S

PI

IMPORT

EXPORT

TCP/IP

PM-OPEN

Choice, if the last value or a substitute value should be exported by using the export type „Process value archive – table“

If it is not possible to determine a archive value in the chosen time period by using the export type „Process value archive - table“ the last value or an engineered substitute value will be used.

Page 10: © Siemens AG 2008 - Subject to modifications WinCC Competence Center Mannheim 2008-04-30Slide 1 Process Management System Economical Automation with Standard

© Siemens AG 2008 - Subject to modifications

WinCC Competence Center Mannheim2008-04-30 Slide 10

Data cache for User Archive data

PM-QUALITY

PM-CONTROL

PM-MAINT

PM-ANALYZE

CONTACT

HOSTS/S

PI

IMPORT

EXPORT

TCP/IP

PM-OPEN

Data cache for User Archive data to increase the performance

While exporting User Archive Data it is possible to chose if information's like the data type and the size of the User Archive column should by temporary saved to increasing the performance during the export. After restart the PM-OPEN EXPORT Runtime the values will determine new.

Page 11: © Siemens AG 2008 - Subject to modifications WinCC Competence Center Mannheim 2008-04-30Slide 1 Process Management System Economical Automation with Standard

© Siemens AG 2008 - Subject to modifications

WinCC Competence Center Mannheim2008-04-30 Slide 11

Dynamic selection of a period with PM-OPEN EXPORT ActiveX

PM-QUALITY

PM-CONTROL

PM-MAINT

PM-ANALYZE

CONTACT

HOSTS/S

PI

IMPORT

EXPORT

TCP/IP

PM-OPEN

With the PM-OPEN EXPORT „DateTimePicker“ ActiveX it is quite easy to set the period of time for the export during the runtime..

Page 12: © Siemens AG 2008 - Subject to modifications WinCC Competence Center Mannheim 2008-04-30Slide 1 Process Management System Economical Automation with Standard

© Siemens AG 2008 - Subject to modifications

WinCC Competence Center Mannheim2008-04-30 Slide 12

Process Management System

For further information, please visit us at:

Internet:http://www.siemens.com/pm-open-export

Email:

[email protected]

Tel: +49 (0) 621 456 -3269

Fax: +49 (0) 621 456 -3334

CONTACT

PM-OPEN

PM-MAINT

PM-ANALYZE

PM-QUALITY

PM-CONTROL