Upload
didiksulistianto
View
216
Download
0
Embed Size (px)
Citation preview
8/7/2019 00_mn1780eu10mn_0003rtc
1/8
s
PLMNSBS BR7.0 system overview
MN1780EU10MN_0003
8/7/2019 00_mn1780eu10mn_0003rtc
2/8
Siemens SBS BR7.0 system overview
MN1780EU10MN_0003
2005 Siemens AG
II
MN1780EU10MN_0003Export Control Marks:N / NThis course is subject to the European Export Control Restrictions.
2005 Siemens AGThe reproduction, transmission or use of this document or its contents is not permitted without express written authority.Offenders will be liable for damages. All rights, including rights created by patent grant or registration of utility model or design,are reserved.Technical modifications possible.Technical specifications and features are binding only insofar as they are specifically and expressly agreed upon in a writtencontract.
8/7/2019 00_mn1780eu10mn_0003rtc
3/8
SBS BR7.0 system overview Siemens
MN1780EU10MN_0003
2005 Siemens AG
III
Sub-sections
SBS BR7.0 systemoverview
MN1780EU10MN_0003
SBS overview 1
BSC architecture 2
BTSplus architecture 3
Enhanced MicroBTS II 4
TRAU architecture 5
Operation and maintenance tools overview 6
Appendix - BS240XS 7
Appendix - enhanced MicroBTS 8
Appendix - design modifications BTSplus II9
Appendix - traditional BTSE architecture 10
Appendix - PicoBTS 11
Appendix - abbreviations 12
Appendix 13
14
15
8/7/2019 00_mn1780eu10mn_0003rtc
4/8
Siemens SBS BR7.0 system overview
MN1780EU10MN_0003
2005 Siemens AG
IV
Warnhinweise
In elektrischen Anlagen stehen zwangslufig bestimmte Teile der Gerte unter Spannung. Einige Teileknnen auch eine hohe Betriebstemperatur aufweisen.
Eine Nichtbeachtung dieser Situation und der Warnungshinweise kann zu Krperverletzungen und
Sachschden fhren.
Deshalb wird vorausgesetzt, dass nur geschultes und qualifiziertes Personal die Anlagen installiertund wartet.
Beachten Sie bitte die ntigen Sicherheitsanforderungen und leisten Sie durch ein problembewusstesVerhalten Ihren Beitrag zur Verhtung von Unfllen jeglicher Art. Gefahren fr Leib und Leben / Lebenund Gesundheit bzw. Verletzungen, die aus sicherheitswidrigem Handeln resultieren knnen, sind voneiner Haftung durch das ICN Training Institute ausgeschlossen.
Warnings
High voltages are present in certain parts of this equipment. Some parts can also have high operatingtemperatures.
Non-observance of these conditions and the safety instructions can result in personal injury or inequipment damage.
Therefore only trained and qualified personnel may install and maintain the system.
Please ensure the necessary safety requirements are met and, by demonstrating a responsibleattitude, play your part in avoiding accidents of any kind. Danger to life and limb, life and well being orinjuries that could result from actions adverse to safety are excluded from any liability on the part ofthe ICN Training Institute.
Atencin
Algunos elementos de este equipo presentan tensiones altas. Incluso algunos componentes puedenpresentar alta temperatura.
No observar estas condiciones y las instrucciones de seguridad puede causar daos personales, ascomo daos al equipo.
Por lo tanto el sistema debe ser instalado y mantenido por personal cualificado.
Tenga presente los requerimientos de seguridad y contribuya a la prevencin de accidentes de todandole, actuando consciente de los problemas que pudieran surgir. El 'ICN Training Institute' no seresponsabiliza por daos y perjuicios resultantes de actuaciones contrarias a los aspectos deseguridad y que pongan en peligro la salud y la vida de las personas involucradas.
Attention
Des tensions leves sont inevitablement prsentes des points spcifiques de cet quipementlectrique. Certains lments peuvent aussi avoir en service des temperatures leves.
La non-observation de ces conditions et des instructions de scurit peut engendrer des dgatspersonnelles ou un endomagement du matriel.
Pour ces raisons seulement le personnel form et qualifi est permi dinstaller et de maintenir lesystme.
Veuillez tenir compte des exigences de scurit ncessaires et contribuer la prvention desaccidents de toutes sortes par un comportement conscient des risques. L'ICN Training Institutedcline toute responsabilit pour les dangers menaant le corps et la vie / la vie et la sant et/ou lesblessures pouvant rsulter d'actes contraires la scurit.
8/7/2019 00_mn1780eu10mn_0003rtc
5/8
SBS BR7.0 system overview Siemens
MN1780EU10MN_0003
2005 Siemens AG
V
Sub-section reference
Sub-section identification Pages
1. MN1780EU10 SBS overview MN_0003 1 - 1162. MN1780EU10 BSC architecture MN_0003 1 - 623. MN1780EU10 BTSplus architecture MN_0003 1 - 884. MN1780EU10 Enhanced MicroBTS II MN_0003 1 - 205. MN1780EU10 TRAU architecture MN_0003 1 - 326. MN1780EU10 O&M tools overview MN_0003 1 - 60
This document consists of 378 pages.
8/7/2019 00_mn1780eu10mn_0003rtc
6/8
Siemens SBS BR7.0 system overview
MN1780EU10MN_0003
2005 Siemens AG
VI
Foreword
The training materials that are handed out are meant for training purposes only. Theaccompanying document is not a replacement for the official system documentation,and is not meant for self-study. The official system documentation is the only licensedreference work for carrying out work in the field. This student file is your ownproperty.
At the end of the course, your course conductor will give you some course evaluationsheets. We ask you to fill out these sheets and would be pleased to receivesuggestions for course improvement regarding the carrying out of the courses andmaterials used.
We at Siemens AG wish you successful training.
Training management
8/7/2019 00_mn1780eu10mn_0003rtc
7/8
SBS BR7.0 system overview Siemens
MN1780EU10MN_0003
2005 Siemens AG
VII
Declaration
I confirm, that the software made available to me during the courses from the ICNTraining Institute for training and practice purposes, will not be further copied outsideof the training.
Furthermore I assure that no software will be copied on to the training PCs, withoutthe explicit consent of the trainer.
With my signature on the attendance list, I confirm that I will adhere to both of theabove requests.
8/7/2019 00_mn1780eu10mn_0003rtc
8/8
Siemens SBS BR7.0 system overview
MN1780EU10MN_0003
2005 Siemens AG
VIII