www.legrand.co.uk
ALPHAREX / PRODUCT GUIDE
AlphaRex move with the times
Distributor :
ALP
AR
EX L
FT.0
3.20
05.1
0K
The Legrand logo is a registered trademark of the Legrand groupof companies
LEGRAND ELECTRIC LIMITEDGreat King Street North, Birmingham, B19 2LF
Customer Services : Tel : 0870 608 9009 Fax : 0870 608 9008
Technical : Tel : 0870 608 9020 Fax : 0870 608 9021
E-mail : [email protected] : www.legrand.co.uk
DISTRIBUTION CENTRES
1. Glasgow Tel : 0141 764 2200Fax : 0141 764 2201
2. LeedsTel : 0113 233 9950Fax : 0113 233 9964
3. BirminghamTel : 0845 605 4333Fax : 0845 605 4334
4. LondonTel : 01895 458777Fax : 01895 458778
E-mail : [email protected]
1
2
3
4
www.legrand.co.uk
02692_LG AlphaRex Lft/aw.qxd 23/2/2005 10:43 Page 1
Adaptor, sof tware and data key
Set-up, save, edit and manage your settings
using AlphaRex’s advanced PC
programming software
The easy to usetime switch...letting you work faster
24/7 display al lows totalcontrol and accuracy
Finger protect ionterminals wi th
screws
4 funct ion keys keepsprogramming simple
Clear display makes the switcheasy to read and fol low
New additions to the AlphaRex rangemake programming even easier.
Units can now be set-up by followingsimple on-screen instructions or,alternatively, using the data key whichcan be plugged directly into a PC.
Fast programming
Using the PC adaptor,you can downloadsaved programmes onto the data key andtransfer them to thetime switch.
When the data key isinserted into theAlphaRex,‘DATA KEY’will be displayed. Youshould then select‘READ’ to transfer thestored data on to thetime switch.
Flexible settings
Ever needed to set upseveral programmesfor different times of the year? ThenAlphaRex has thesolution for you.Use the data key tostore differentprogrammes forsummer and winter.
If only one programme is required, the datakey is still a usefulback-up as it allowsyou to quickly restorethe programme.
Efficient copying
Even without a PC, youcan use the data keyto store or transferdata from one timeswitch to another.Simply choose the‘WRITE’ option fromthe display.
The data key can thenbe used to transferthe saved programmeto additional timeswiches.
32
02692_LG AlphaRex Lft/aw.qxd 23/2/2005 10:44 Page 3
AlphaRex... the simple lifeIt has never been easier toprogramme a time switch.
Select ‘PROGRAM’ in the menu Select ‘NEW’ and choose requiredswitching days
Enter desired programme t imes
Easy to edi t funct ions
Going on hol iday? Justput in hol iday dateswith ‘ON’ or ‘OFF’
AlphaRex includes a host of additional
functions for the installer and end user
making it easy to programme, easy to
edit...easy to get on with life.
Storedprogrammes
at a glance
Switching mode
Time and date
Conf irmat ion
Data key slot
Programming mode
Operat ion mode
Navigat ion
Need to control thelength of use? Selectthe integrated hourcounter
Pulse opt ion with 84start t imes and apulse durat ion of upto 59mins and 59secs
54
The AlphaRex has been developed to ensure that
simplicity and ease of use is key. Each on-screen
menu is so clear that there is no need to study a
manual before use.
The AlphaRex is pre-installed with European time, date
and daylight saving hours. Simply set the hour to UK
time and the time switch is ready to programme.
Multiple options ensure that AlphaRex functions
will meet all of yourrequirements
02692_LG AlphaRex Lft/aw.qxd 23/2/2005 10:44 Page 5
6
AlphaRex time switchesdigital for rail 44
Conform to IEC/EN 60730-1 and EN 60730-2-7Text based programming for easier useMount on DIN rail EN 607154
Pack Cat. Nos. AlphaRexTM
Accuracy : ± 0·2 second per dayClearly visible LCD matrix display shows the data at a glanceProgrammable for 1 minute minimum at 1 minutesteps either as 24 hour or 7 day using pre-set groupsof days : Mon-Sun, Mon-Fri, Sat-Sun or individual daysProgrammable either directly on the time switch or via a PC with the Legrand software and data keyData keys can also be used to transfer programmesfrom one unit to another or used to store data andprovide a security back up1 programme consists of 1 ON and 1 OFF time and the allocation of any day of the week or acombination of days, plus the selected channel on the two channel version
Additional features :Built in hour counter up to 65535 hours with resetBack lit display and buttons for easy working duringset upLithium high temperature battery provides a 6 yearworking reserveEEPROM memory keeps your programme storedindefinitelyOptional automatic summer/winter time changeManual override (permanent ON or OFF until manual reset)Automatic override, changes contact position untilnext automatic ON time(ON becomes OFF; OFF becomes ON, till nextprogrammed ON)Sealable transparent cover with or without data key insertedHoliday and random security programmesD21 version includes a PULSE function providing up to 84 starts from 1 second to 59 minutes 59 seconds duration
AlphaRex D21 24 hour or 7 day56 programmes, 1 channel1 x 250 V 50 Hz, 16 A voltage free c/o contact
1 0047 61 230 V 50/60 Hz supply voltage1 0047 63 24 V 50/60 Hz or DC supply voltage
AlphaRex D22 24 hour or 7 day2 x 28 programmes, 2 channels2 x 250 V 50 Hz, 16 A voltage free c/o contacts
1 0047 71 230 V 50/60 Hz supply voltage1 6047 72 24 V 50/60 Hz or DC supply voltage
Pack Cat. Nos. Accessories
Data key1 0047 72 Enables programmes to be stored and/or transferred
from one time switch to anotherWhen used with the USB adaptor (Cat. No. 0047 73below) the data key can by programmed via a PC
USB adaptor with software1 0047 73 Enables programmes to be written or read on a PC
then transferred using the data key (Cat. No. 0047 72above) to the time switchSystem requirements : Windows® 2000, Windows® ME,Windows® XP, and Windows® 98 second edition, 10 MB free disc space
Data key box1 0057 91 1 module width
Mounts on DIN rail to store data keys
0047 61 0047 72 0047 73
7
AlphaRex time switchesdigital for rail 44
■ Programming ■ Technical information
Type AlphaRex D21 AlphaRex D22Cat. No. 0047 61/0047 63 0047 71/6047 72
Programme 24 hour or 7 day
No. of channels 1 2
No. of ON-OFF 56 2 x 28actions per day/weekPulse start times 84 Nil
Pulse duration 1 second min. to N/A59 minutes 59 seconds
max.
Switchingcapacity :cos ϕϕ = 1 16 Aincandescent lamp 8 Acos ϕϕ = 0·6 10 A
Contact 1 changeover 2 changeoverswitch switches
Terminal capacity 1·5 mm - 4 mm single/1·5 mm - 2·5 mm stranded
IP rating IP 20
Min. prog. time 1 minute
Switching step 1 minute
Accuracy ± 0·2 second per day
Working reserve(1) 6 years
Programme memory Unlimited (EEPROM)
Manual switching Override and permanent
No. of 17·5 mm 2modules
Operating temp. –20 °C . . . +55 °C
Storage temp. –20 °C . . . +60 °C
Weight 130 g 136 g
(1) For time and date only
Just 4 buttons put you in controlSimple, easy to set up and easy to use…
Now set your ON/OFF times…Press the MENU button, select PROGRAM from the menuSelect the function you need i.e. NEW, EDIT, CHECK or DELETE
■ Dimensions (mm)
A programme consists of an ON and OFF time and the assigned day(s)
With pre-installed English text thatcan be changed to German, French,Spanish or Italian
Central European time and datehave been factory set with Europeansummer/winter time change installed
To set UK time :press MENU button select SET confirm OK;select TIME/DATE confirm OK; amend hour to UK hour confirm OK; confirm remainder OK
Example :Select NEW confirm OK;Select block or individual days confirm OK;Set ON time Hours and Mins. confirm OK;Set OFF time Hours and Mins. confirm OK;Press the MENU button to return to normal operation
You can move forwards or backwards with the –+ buttons
Either programme directly on the time switch or via your PCUsing the data key you can transfer the programme to another timeswitch of the same model
More features than ever before :• holiday programme• hour counter with reset• pulse function• random function• contrast control• more ON/OFF controls
■ Wiring diagramsAlphaRex D21 AlphaRex D22
36
83
50
45
66
02692_LG AlphaRex Lft/aw.qxd 23/2/2005 10:44 Page 7