e u r o t r o n TEST & MEASUREMENTS EUROTRON Instruments S.p.A. Portable Temperature Calibrators Bulletin 09-06.3 E MicroCal T series Ranges from -50°C to 1100°C High stability and uniformity Fast cool-dow n design Microprocessor temperature controller RS232 seri al interface CalpMan 2000 documenting P C software Eurotron - One of the leaders in high t echnology equipment: high accuracy calibrators - non-contact IR thermometers - portable f lue gas analyzers. ns  I t r   n u   o m    r    t e     o n       r t          u s          E n s I t r u m t e n t s E ISO 9001 Q   d u  e    t a  l  n i  t a y r  G

09-06.3 E MicroCal T Series

Embed Size (px)

Citation preview

Page 1: 09-06.3 E MicroCal T Series

8/3/2019 09-06.3 E MicroCal T Series

http://slidepdf.com/reader/full/09-063-e-microcal-t-series 1/4

e u r o t r o n

TEST &

MEASUREMENTS

EUROTRON Inst ruments S .p .A.

Portable TemperatureCalibrators

Bulletin 09-06.3 E

M icroCal T series

Ranges from -50°Cto 1100°C

High stability anduniformity

Fast cool-dow ndesign

Microprocessortemperaturecontroller

RS232 serial

interfaceCalpMan 200 0documenting P Csoftware

Eurotron - One of the leaders in high technology equipment: high accuracy calibrators - non-contact IR thermometers - portable f lue gas analyzers.

n s I t r n u o m r te o

n rt us E

n sI t r u mte

ntsE

ISO 9001

Q du e ta l ni t ay r G

Page 2: 09-06.3 E MicroCal T Series

8/3/2019 09-06.3 E MicroCal T Series

http://slidepdf.com/reader/full/09-063-e-microcal-t-series 2/4

TEST &MEASUREMENTS

NE W ! NE W !

Portable Dry-block and FluidTemperature Calibrators

GENERAL M icroCal T100 M icroCal T350

Designed for Testing and ca librating temp erature sensors Switch test input for therm ostat Compa ct, rugged, and easy to use

Microprocessor temp erature controller optional RS232 serial interface

TM and CalpMan 2000 Windows software

Compa ct, rugged a nd easy to use.

Built-in reference Pt100 with high ac curac y 0.01°C resolution indicator Auxiliary input s for external Pt100 and therm ostat switch-test.

Internal fa n and Peltier unit for fastcool-down.RS232 seria l interfa ce and optional CalpMan 2000

TM Windows software

The temperature parameter representthe most important factor to fulfil quality,operational safety and reliability ofindustrial processes. Thermocouples.resistance thermometers and any othertemperature sensors. When installed ina industrial process, they are subjectedto mechanical, thermal and chemicalstresses which accelerate their ageing.

Therefore it is a recommendedprocedure to inspect, check andcalibrate each sensor during thecommissioning phase and at regular andprogrammed time intervals.The temperature calibrators seriesMicroCal T include five different, ruggedand transportable units designed toobtain a controlled temperature with highstability, high uniformity in all calibratorsranges.

Internal block temperature stabilityA built-in microprocessor basedcontroller handle the man-machine

interface, the internal logic and assuresthe high stability of the internal metalblock through a sophisticatedtemperature algorithm.

A complete Automatic CalibrationSystemThe MicroCal T can be used togetherwith a Personal Computer, amultifunction high precision calibratorMicroCal 200/200+ (see bulletin 08-44)and a CalpMan 2000 Windows® software package to improve a trueautomatic temperature calibrationsystem.Using the RS232 interfaces of theinstruments it is possible to programtrough the PC the complete testprocedure for Your thermocouple orresistance thermometer to be certificate.The MicroCal 200 is able to read thetesting thermo-element with the desiredaccuracy and the software calculate theerrors and prepare the certificate.

Table A Options0 None1 Carrying case3 RS232 serial interface4 blank insert5 2 holes insert ( φ 6.5 - 12.5 mm)

Table B Power supply1 120 V USA plug2 230 V Schuko plug3 240 V UK plug4 230 V European plug

Table C Report of calibration1 Eurotron Report

Table A Options0 None1 Alluminium carrying case +

EE460010, EE460013 andEE460015 inserts + extration tool

4 Vinyl carrying case

Table B Power supply1 120 V USA plug2 230 V Schuko plug3 240 V UK plug4 230 V European plug5 100 V Japan/USA plug

Table C Report of calibration1 Eurotron Report

ORDERING CODE

ORDERING CODE

Cat . 8172 - A - B - C

Cat . 8150 - A - B - C

Page 3: 09-06.3 E MicroCal T Series

8/3/2019 09-06.3 E MicroCal T Series

http://slidepdf.com/reader/full/09-063-e-microcal-t-series 3/4

NE W ! NE W !

TEST &MEASUREMENTS

MicroCal T1100MicroCal T500

A w ide range of applications

MicroCal T200 Fluid

Opera ting range: Environment to + 200°C

Optional 2 inputs for externa l 3/4 wires Pt100 and Tc J, K, N, R, S.Therm ostat switch-test input .RS232 interfac e a nd opt ional

TM CalpM an 2000 Windows software.Wate r (< 90°C), 47V20 Silicon oil (< 120°C) and 47V100 Silicon oil (< 200°C).

Operating range from Tam b to + 600.0 °C

Built-in reference Pt100 with high ac curac y 0.01°C resolution indicator.Auxiliary input for external Pt100.

Therm ostat switch-test input .Internal fan for rap id c ool-down.RS232 interface a nd optiona l

TM CalpM an 2000 Windows software

Tem pera ture sensors field and laboratory inspection and calibration.Optional 2 inputs for externa l 3/4 wires Pt100 and Tc J, K, N, R, S.Therm ostat switch-test input .

Internal fan for rapid cool-down.Opera ting rang e from + 200 °C to + 1100 °C RS232 interface a nd optiona l

TM CalpMan 2000 Windows software

Table A Options0 None1 Alluminium carrying case + EE460016

and EE460017 inserts + extration tool2 Maximum temperature +600°C4 Vinyl carrying case7 Special drilling for 50mm block (550°C)7X Special drilling for 65mm block (550°C)8 Special drilling for 50mm block (600°C)8X Special drilling for 65mm block (600°C)

Table B Power supply1 120 V USA plug2 230 V Schuko plug3 240 V UK plug4 230 V European plug5 100 V Japan/USA plug

Table C Report of calibration1 Eurotron Report

Table A Options0 None

2 n.2 Tc & Pt100 inputs9 Special φ44mm block

Table B Power supply1 120 V USA plug2 230 V Schuko plug3 240 V UK plug4 230 V European plug5 100 V Japan/USA plug

Table C Report of calibration1 Eurotron Report

Table A Options0 None

1 Vinyl carrying case2 n.2 Tc & Pt100 inputs

Table B Power supply1 120 V USA plug2 230 V Schuko plug3 240 V UK plug4 230 V European plug

Table C Report of calibration1 Eurotron Report

ORDERING CODE ORDERI NG CODE ORDERI NG CODE

Cat . 8174 - A - B - C Cat . 8176 - A - B - C Cat . 8152 - A - B - C

Page 4: 09-06.3 E MicroCal T Series

8/3/2019 09-06.3 E MicroCal T Series

http://slidepdf.com/reader/full/09-063-e-microcal-t-series 4/4

TEST &MEASUREMENTS

S p e c i f i c a

t i o n s m a y c h a n g e w

i t h o u

t n o

t i c e .

Accessories

W hat you needyou can find here

Metal inserts for T500 (nr. / holes -ID):cat. EE460016 undrilledcat. EE460017 (1 / 9.5 mm)cat. EE460018 (1 / 8.0 mm)cat. EE460019 (1 / 10.0 mm)cat. EE460020 (1 / 11.0 mm)cat. EE460021 (1 / 12.0 mm)

Metal inserts for T100 (nr. / holes -ID):cat. EE460010 undrilledcat. EE460011 (1 / 14.5 mm)cat. EE460012 (1 / 17.5 mm)cat. EE460013 (2 / 6.5-12.5 mm)cat. EE460014 (3 / 6.5 mm)cat. EE460015 (3 / 4.5-6.5-9.5 mm)

Metal inserts for T350 (nr. / holes -ID):cat. EE460037 undrilledcat. EE460038 (2 / 6.5-12.5 mm)

Custom inserts and blocks diameters are available on request.

Model MicroCal T350 MicroCal T100 MicroCal T200Fluid

MicroCal T500 MicroCal T1100

Temp. range °C amb. to 350 -50 from amb. to 150 amb. to 200 amb. to 550 (600) 200 to 1100*Stability °C ± 0,1 ± 0,03 ± 0,02 @150°C ± 0,05 @ 450 °C ± 0,3 @ 1000°CUniformity

RadialAxial

± 0,1 (100°C)± 0,2 (80 mm)

± 0,03± 0,03

± 0,2 (450°C)± 0,8 (80 mm)

± 0,4± 0,4

Stability indicator - Audio+Visual Audio+Visual Audio+Visual Accuracy °C ± 0,4 ± 0,15 ± 0,15 ± 0,3 ±3Resolution °C 0,1 0,1 / 0,01Ext. Probereadings

- Std. (Pt 100) opt. (Pt100 & Tc) Std. (Pt 100) opt. (Pt 100 & Tc)

Temp. Read out - °C °C/°F °C/°F °C/°F °C/°FInterface Optional (RS232) RS 232 RS 232 RS 232 RS 232Heating time tomax.

20°C/ min. 20 °C / min. 10°C/ min. 20°C/ min. 18 °C / min.

Cooling time tomin.

10°C/min. 25 °C / min. 3°C/ min. 25°C/ min. (100°C) 6 °C / min.

Switch test Standard Standard Standard Standard StandardWell depth mm 125 135 150 185 225Oven well diam.

mm 26 6.5 / 26 50 4 holes:

4,5 / 6,5 / 9,5 / 1744

Dimensions mm 230x220x105 300x370x140 330x340x160 300x370x140 170x330x450Weight Kg 3,5 10 8 8 11Power 300VA 300VA 500VA 800VA 850VACarrying case optional optional optional optional -

Standardpackaging

Mains cable3 holes drilled insert:

4.5 / 6.5 / 9.5 mmextraction tool

test cableuser manual

Mains cable3 holes drilled insert:

4.5 / 6.5 / 9.5 mmextraction tool

test cableuser manual

Mains cableUser manual

Support for glassthermometersextraction tool

test cable500cc silicon oil

Mains cableuser manual

extraction toolstest cable

Mains cableuser manual

extraction tools4 holes drilled insert:7 / 9 / 11 / 13,5 mm

* Limited at 1000°C with 100Vac supply

Specifications

from Tamb to 200°C

from 200°C to 25°C

for metal inserts only

0,1 / 0,010,1 / 0,01

Audio+Visual

0,1 / 0,01

± 0,5

Distributed by:

eur ot r onw w w . e u r o t r o n . c o m

EUROTRON Instrum ents S.p.A. V.le F.lli Casiraghi 409/413

I 20099 Sesto S. Giovanni (MI)Tel.: +39-02 248820.1Fax: +39-02 2440286