4
Bulletin 08-45.3 E - ed. 04-2007 Automatic Management of the Calibrations for the Process Instrumentation Compatible with all the MicroCal Series Calibrator Documenting Calibrator Management Automatic Management of the Calibrations for the Process Instrumentation Simultaneous Certification of thermoelements with multiplexer Option SQL Database FDA CFR21 Part11 Optional Compliant Multiuser Management Compatible with all the MicroCal Series Calibrator Calibration Procedure Manager Software Package CalPMan 2007 Q s t I n r u n m o r e t n o r t s u E C e m r e t t i f s i e y S d y Q t i u a l www.einstrumentsgroup.com MULTIFUNCTION CALIBRATORS All descriptions are related to a fully optioned instrument. See last page for the different configurations CalpMan 2007 Advanced CalpMan 2007

CalPMan 2007 - Hoskin Scientifique€¦ · MicroCal P200 (documenting) MicroCal PM200 (documenting) MicroCal T100 MicroCal T500 MicroCal T1100 79. Calibration Procedure Manager Software

  • Upload
    others

  • View
    24

  • Download
    0

Embed Size (px)

Citation preview

  • Bu

    lletin

    08

    -45

    .3 E

    - e

    d. 0

    4-2

    00

    7

    Automatic Managementof the Calibrationsfor the Process Instrumentation

    Compatible with all the MicroCalSeries Calibrator

    Documenting CalibratorManagement

    Automatic Managementof the Calibrationsfor the Process Instrumentation

    Simultaneous Certificationof thermoelements with multiplexer

    Option SQL Database

    FDA CFR21 Part11 OptionalCompliant

    Multiuser Management

    Compatible with all the MicroCalSeries Calibrator

    Calibration Procedure ManagerSoftware Package

    CalPMan 2007

    QstIn r un mor et nor tsuE

    Ce mr et tif sie ySd yQ tiual

    www.einstrumentsgroup.com

    MULTIFUNCTIONCALIBRATORS

    All descriptions are related to a fully optioned instrument. See last page for the different configurations

    CalpMan 2007 Advanced

    CalpMan 2007

  • For over 20 years, Eurotron Instruments has combined ISO 9001 requirements, industry experience, and best practices to develop a technologically advanced software application. Calibration Procedure Manager 2007 is designed to be used in a variety of industries, including general manufacturing, automotive, and calibration service companies. In addition, departments such as R&D, QA/QC, production, and engineering, can customize Calibration Manager to meet their specific needs.

    The standard version manage the laboratory automatic procedures and it is compatible with the Eurotron documenting calibrators in order to run off-line procedures, useful for certify the instrumentation directly on the process.

    Two different software versions are availabe: CalpMan 2007 and CalpMan 2007 Advanced.The main features are:easy to useISO9001 compliantStandards and Instruments managing;automatic procedure performing;built-in managing for documenting calibratorstraceable and customizable report printing

    General

    The CalPMan 2007 provides a comprehensive solution to the calibration requirements and organizational demands of the ISO 9001standard. The software's robust feature set tracks the required information and produces the necessary documentation to show that the system is in compliance.

    Trace standards used to calibrate an instrument :

    Track as found and as left data Indicate the pass or fail status of a piece of equipment Complete management of the instrument identification card

    ISO 9001:2000

    Instrument Setup

    All the instruments data are stored into a dabase that includes the complete informations (instrument record) and the relative calibration expiration date for each instrument. Is it also possible to print a table containing the complete list of instruments information, or a selected list including the calibration expirated date only, in order to better program the laboratory or the maintenance periodic activity.There are two different databases: the one related to the instrument that have to be verified (Tag), and the second one related to the referent instrument (Standard).

    ON-LINE Procedures

    With the CalPMan 2007 you can program a complete test strategy including the used standards, the test-points, the error limits and to assign it to one ore more instrument subject to a verification.The software will automatically manage the instruments thanks to one or two RS232 ports when it run with the Eurotron's MicroCal Series Calibrators.It is also possible run the software with analog instruments too, by manually typing in the values using the computer keyboard.

    MULTIFUNCTIONCALIBRATORS

    Calibration Procedure ManagerSoftware Package

    78

  • Graphic Module

    The graphic module for a more intuitive and immediate representation of the test results is standard.With the module you can insert and print the graphic in the calibration certificate.

    OFF-LINE Procedures

    For each calibration procedure the CalPMan 2007 allows you to set the complete test strategy: define the Standards, the test points, the error limits and to assign them to one or more equipment for the automatic test. If the calibrator type is an Eurotron Documenting Calibrator (e.g. our MicroCal 20 DPC) the software will transfer the complete calibration procedure strategy into the calibrator memory. Eurotron Documenting calibrators can perform the test without the connection to the PC and can upload the results to the Calpman 2007 database for processing

    MULTIFUNCTIONCALIBRATORS

    Calibration Procedure ManagerSoftware Package

    TMWindows VISTA

    TM TMWindows 98, Windows 2000, TMWindows XP,

    TMPentium 2 Processor128 MB RAM, 150 MB Hard disk space free CD-ROM, Two RS232 or USB serial ports

    Minimum System Requirements Compatible Instruments

    UniCalMicroCal 1+MicroCal 2+MicroCal 10MicroCal 20 DPC (documenting)MicroCal 20TMicroCal 200/200+MicroCal 2000+

    (documenting) (documenting)

    (documenting)

    The CalpMan 2007 includes the communication drivers for the following instruments:

    MicroCal PMicroCal P20 (documenting)MicroCal P100MicroCal P200 (documenting)MicroCal PM200 (documenting)

    MicroCal T100MicroCal T500MicroCal T1100

    79

  • Calibration Procedure ManagerSoftware Package

    Sp

    eci

    fica

    tion

    s m

    ay

    cha

    ng

    e w

    itho

    ut n

    otic

    e

    Report

    With the Calpman 2007 you can personalize and print the calibration report in an easy and immediate way.Calpman 2007 includes same report models (template) already customized by Eurotron using all the know-how of our metrologic laboratory. You have only to add your company logo and your description and print the report. It is also possible customize an own personal report by running the simple CristalReport application included into the software package.

    CFR 21 Par.11 compliant

    SQL Database

    CalpMan 2007 Advanced

    This version runs advanced functions to the control of the test procedures.

    The 3-instruments simultaneously management is ideal for thermometric set that requires the multiple calibration of thermoelements. This feature allows the operator to create complex automatic procedures using three synchronized instruments, such as a thermostatic bath, a calibrator with reference sensor and an analog scanner.

    The advanced set-point control allows the operator to select the proper algorithm in order to better measuring the programmed test point.

    With the multi-parameter procedure the operator can manage different physical parameter in one procedure only. Is it possible type in a special text for the operator (i.e. for changing the connection) for each test point.

    Multi-certificate:is it possible the simultaneously certification up to 16 thermoelements (TCs or RTDs) when using the analog scanner.

    This optional module for the CalpMan 2007 Advanced software package contains all the features required by the American law FDA CFR21 par. 11 in terms of data security. This module use the following options: user and password management at different access levels, data cryptography, modification data recording and electronic signature.The module also allows the operator to remove the paper printed archive, thanks to the electronic signature of the documents.

    This optional module for the CalpMan 2007 Advanced software package contains all the features for the management of both the verification activity and the distributed calibration. The SQL database (the SQL server and the licences are not included) can be resident into your company server and it can manage an unlimited number of remote users that allows a better productivity, quality and integration of all the laboratory data.

    MULTIFUNCTIONCALIBRATORS