09_Types of pushover Analysis

Embed Size (px)

DESCRIPTION

Classification

Citation preview

  • Types of analysis:

    Linear static, linear

    dynamic and non

    linear static

    Paulo B. Loureno

    [email protected]

    www.civil.uminho.pt/masonry

  • Safety

    Assessment of

    Existing Buildings

  • Institute for Sustainability and Innovation in Structural Engineering

    3 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Non-linear static analysis

    Linear static analysis

    Sim

    plif

    ica

    tion

    Structural Analysis Methods (Static)

  • Institute for Sustainability and Innovation in Structural Engineering

    4 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Early Structural Analysis

    Ut tensio sic vis or / E = is the elasticity law established by R.

    Hooke in 1676.The theory is so extensively used that its limitations and

    deficiencies are often forgotten. This is in opposition with early forms of

    limit analysis.

    Cantilever beam according to Galileo (1638) and evolution

    of the hypothesis for the stress distribution at AB

    Retaining wall according

    to Coulomb (1773)

    B

    A

    P

  • Institute for Sustainability and Innovation in Structural Engineering

    5 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Modern Structural Analysis

    As structural collapse does not generally coincide with the appearance

    of the first crack or localized early crushing, it seems that the elasticity

    theory is a step back with respect to limit analysis

    Full nonlinear analysis (the most advanced form of structural analysis)

    covers the complete loading process, from the initial stress-free state,

    through the weakly nonlinear behavior under service loading, up to the

    strongly nonlinear behavior leading to collapse

    Interest has been growing since 1970s but it remains a field for

    selected (few) specialists due to complexity (knowledge) and costs

    (time) involved

    The possibilities are immense and several commercial software

    packages include some form of nonlinear behavior, but an incorrect use

    can be very dangerous

  • Institute for Sustainability and Innovation in Structural Engineering

    6 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Modern Structural Analysis The modern use of nonlinear analysis focuses mostly on these three

    fields:

    Complex / stringent safety requirement structures (e.g. nuclear plants,

    dams, bridges)

    Virtual laboratory for parametric studies

    Existing structures (evaluation, repair, rehabilitation)

    Three types of non-linearities may arise:

    Material (or physical) nonlinearity

    F

    Geometrical

    nonlinearity

    Contact nonlinearity

    Steel

    (code model) Concrete

    (code model)

  • Institute for Sustainability and Innovation in Structural Engineering

    7 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Existing Buildings

    Settlements

    Vertical dead + live load

    Vehicles

  • Institute for Sustainability and Innovation in Structural Engineering

    8 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Modern Earthquake Design

    Macro-models (Braga, Liberatore, DAsdia, Magenes, Lagomarsino, etc.)

    Storey model (Por) Tomazevic

    Finite element model

    (Many authors)

    Elastic analysis leads

    to excessively

    conservative

    solutions for

    unreinforced,

    confined, and

    possibly, reinforced

    masonry

  • Institute for Sustainability and Innovation in Structural Engineering

    9 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Example of Analysis of an Arch

    The solution: Ut pendet continuum flexile, sic stabit contiguum rigidum inversum as hangs the flexible line, so but inverted will stand the rigid arch.

    In 1675 Hooke provided the solution for he

    equilibrium of an arch by means of an

    anagram included in the book "A

    description of Helioscopes and some

    other Instruments", which was only

    deciphered after his death in 1703.

    Robert Hooke (1635-1703)- Principle of the inverted catenary

  • Institute for Sustainability and Innovation in Structural Engineering

    10 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Graphic Statics

    The arch is first decomposed in a series of real or fictitious voussoirs

    separated by a series of planes (the planes do not need to be parallel)

    The thrust line is defined as the geometrical locus of the points of

    application of the sectional forces (the resulting forces over each plane

    between voussoirs) across the arch An arch is stable if it is possible

    to find a thrust line contained

    between its boundaries

  • Institute for Sustainability and Innovation in Structural Engineering

    11 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Kinematic Analysis

    Charles-Agustin COULOMB (1736-1806) proposed in 1773 the first general

    and accurate theory on the stability of masonry arches

    The basic assumptions are:

    (1) Sliding between voussoirs is unlikely due to the existing frictional forces

    (2) Collapse will be caused by the rotation between parts due to the

    appearance of a number of hinges. The location of the hinges is a priori

    unknown but can be determined by the method of maxima and minima

  • Institute for Sustainability and Innovation in Structural Engineering

    12 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Kinematics of 4-hinge collapse

  • Institute for Sustainability and Innovation in Structural Engineering

    13 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Correspondence with THRUST LINE theory: a hinge will develop each

    time the equilibrium line becomes tangent to an alternate boundary. In

    this condition (failure), the thrust line is determined and unique.

  • Institute for Sustainability and Innovation in Structural Engineering

    14 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Collapse of an arch brought experimentally to failure

  • Institute for Sustainability and Innovation in Structural Engineering

    15 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Static Analysis Methods (I)

    Linear Elastic Analysis

    elastic properties + maximum admissible

    stress

    Kinematic Collapse Mechanism Analysis

    inelastic properties = friction angle +

    tensile and compressive strengths

    Static Thrust Line Analysis

    Non-linear Analysis (Physical and Combined)

    FULL inelastic properties (ft = 0 and ft 0) + elastic properties

    5

    2.5

    3

    1.25 10 kN

  • Institute for Sustainability and Innovation in Structural Engineering

    16 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Sta

    tic

    An

    aly

    sis

    Me

    tho

    ds

    (II)

    Max. 0.64 N/mm2

    Linear Elastic

    Kin. load factor : 1.8

    Failure Mechanism

    Geo. load factor : 1.2

    Thrust Line

    Min. -1.0 N/mm2

    Linear Elastic

    Min. -5.4 N/mm2

    Phys. Non-Linear

    Min. -5.4 N/mm2

    Comb. Non-Linear

  • Institute for Sustainability and Innovation in Structural Engineering

    17 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Static Analysis Methods (III)

    0.0

    0.5

    1.0

    1.5

    2.0

    2.5

    3.0

    0 5 10 15

    Vertical displacement at quarter span (mm)

    Lo

    ad

    facto

    r

    Limit analysis

    ft = 0, Physically non-linear

    ft = 0, Physically / Geometrically non-linear

    ft = 0.2 N/mm2, Physically non-linear

    ft = 0.2 N/mm2, Physically / Geometrically non-linear

  • Institute for Sustainability and Innovation in Structural Engineering

    18 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Static Analysis Methods (III)

    Approach/Analysis type

    Semi-circular arch

    Allowable stresses (fta=0.2 N/mm

    2)

    0.31

    Kinematic limit analysis

    1.8

    Geometric safety factor

    1.2

    ft = 0, Physically non-linear

    1.8

    ft = 0, Physically and geometrically non-linear

    1.7

    ft = 0.2 N/mm

    2, Physically non-linear

    2.5

    ft = 0.2 N/mm2, Phys. and geom. non-linear

    2.5

    The safety factors of a linear elastic analysis and a static limit analysis cannot

    be compared with the remaining safety factors.

    Physically non-linear analysis and kinematic limit analysis yield the same failure mechanisms and safety factors?

    The consideration of a non-zero, yet low and degrading, tensile strength increased the safety factors considerably. The post-peak is a key issue.

    Different methods of analysis lead to different safety factors and different completeness of results.

  • Institute for Sustainability and Innovation in Structural Engineering

    19 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    More on Static Analysis Methods

    Safety factor: 124%

  • Institute for Sustainability and Innovation in Structural Engineering

    20 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Non-linear time history analysis

    Non-linear static analysis

    Linear elastic time history analysis

    Modal superposition

    Linear static analysis

    Sim

    plif

    ica

    tion

    Structural Analysis Methods: Dynamic

  • Institute for Sustainability and Innovation in Structural Engineering

    21 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    In the recent years new methods of seismic assessment and design have been developed, particularly with respect to push-over analysis

    Two methods of analysis can be distinguished:

    - Traditional force method, combined with control of performance requirements

    based on deformation

    - Displacement based method, in which the analysis starts by defining a target

    displacement (measuring the structural response).

    Push-Over Analysis (I)

  • Institute for Sustainability and Innovation in Structural Engineering

    22 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    The dimensions of the structural members are considered

    The stiffness of the members is also considered (the codes might consider elastic stiffness or 30 to 50% of the elastic stiffness)

    Periods are based on stiffness (Note: The design forces can be reduced about 30 to 50% if the stiffness is reduced to the half)

    Forces are distributed in the elements according to the stiffness

    Traditional Force Method

    Push-Over Analysis (II)

  • Institute for Sustainability and Innovation in Structural Engineering

    23 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Moment-curvature curves for circular columns (D=2 m, fc=35 MPa, fy=450 MPa)

    Mom

    ent

    (kN

    m)

    Curvature (1/m)

    Percentage of reinforcement = 1%

    Curvature (1/m)

    Percentage of reinforcement = 3%

    Mom

    ent

    (kN

    m)

    Push-Over Analysis (III)

    Stiffness and strength are correlated!!

  • Institute for Sustainability and Innovation in Structural Engineering

    24 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    HA HB HC C A B

    Force Based Design Displacement Based Design

    Stiffness: proportional to 1/H3 proportional to 1/H

    Shear: proportional to 1/H3 proportional to 1/H

    Moment: proportional to 1/H2 equal

    Reinforcement: proportional to 1/H2 equal

    Ductility: equal (!) proportional to 1/H2

    ` F Hc

    HA

    HB

    Push-Over Analysis (IV)

  • Masonry

    Structures With

    Box Behavior

  • Institute for Sustainability and Innovation in Structural Engineering

    26 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Recent test results: Rigid diaphragm

    Worst case scenario: Embedded ring beam + Unfilled vertical joints

    Moderate damage up to 100% of the design earthquake in Lisbon

    Ductile failure for 250% of the design earthquake in Lisbon

  • Institute for Sustainability and Innovation in Structural Engineering

    27 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Seismic pushover analysis simulates the evolution of the condition of structures during earthquakes, through application of incremental

    horizontal forces until collapse

    Assumptions of box behaviour and in-plane response are considered

    Experimental results show that URM possesses considerable

    capacity for inelastic

    deformations, and then the

    application of nonlinear analysis

    is obvious

  • Institute for Sustainability and Innovation in Structural Engineering

    28 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    POR Storey Mechanism Developed in former Yugoslavia and Italy as a reaction of the Skopje earthquake

    in 1963, and implemented in the region Friuli-Venezia Giulia after the Friuli earthquake in 1976 (DT2, 1977)

    The following hypothesis are considered:

    Thickness of the wall is constant in each level

    Slabs are rigid in-plane diaphragms

    Ends of the piers do not rotate, but only suffer translation

    Behavior of the piers is elastic-perfectly plastic, with a predefined ductility

    Elastic stiffness of each panel remains constant

    Panels collapse by diagonal shear according the Turnsek-Cacovic expression

    Tomaevi, Braga & Dolce

  • Institute for Sustainability and Innovation in Structural Engineering

    29 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Additional Macro-Mechanisms Since the 1980s, observation of damage in masonry

    buildings subjected to significant vertical load due to use

    of slabs, and constituted by slender piers, introduces a

    new trend of research on the combined flexural mechanism

    Comb. flexural Diagonal shear Sliding shear Mixed

    0 0.5 1 1.5 2 2.5

    Slenderness (H/L)

    0

    0.25

    0.5

    0.75

    1

    Diagonal shear

    Combined

    flexural

    Sliding

    Dim

    ensio

    nle

    ss

    no

    rma

    l str

    ess (

    /fm

    )

    0 0.5 1 1.5 2 2.5

    Slenderness (H/L)

    0

    0.25

    0.5

    0.75

    1

    Diagonal shear

    Combined

    flexural

    Sliding

    Dim

    ensio

    nle

    ss

    no

    rma

    l str

    ess (

    /fm

    )

  • Institute for Sustainability and Innovation in Structural Engineering

    30 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Early Improvements in Italy Initially these methods only had an impact in the scientific community and the

    POR persisted as the method most used by Italian designers

    1 2 3

    RAN PEFV MAS3D

    (Raithel & Augenti) (DAsdia & Viskovic) (Braga et al.)

  • Institute for Sustainability and Innovation in Structural Engineering

    31 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    A Generation of Design Methods in Italy As a consequence of the 2002 Molise Earthquake the new Italian code OPCM

    3274/2003(3431/2005) was introduced, and macro-elements methods emerge as

    modern and practical tools

    Spandrel

    Pier

    Joint

    SAM 3Muri 3DMacro

    (Magenes et al.) (Lagomarsino et al.) (Cali et al.)

  • Institute for Sustainability and Innovation in Structural Engineering

    32 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Validation Example

  • Institute for Sustainability and Innovation in Structural Engineering

    33 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Or even use SAP 2000

    One-dimensional macro-element

    Bi-dimensional macro-element

  • Institute for Sustainability and Innovation in Structural Engineering

    34 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Program Country Code Approach Web adress

    AEDES Italy Italian FEM and SCM www.aedes.it

    CMT+L Spain Eurocode FEM www.arktec.com/cmtl.htm

    FEDRA Norway Eurocode FEM www.runet-software.com/FEDRA.htm

    WIN-Statik MurDim+ Sweden ? ? www.strusoft.com

    Por 2000 Italy Italian SCM www.newsoft-eng.it/Por2000.htm

    TQS CAD/Alvest Brazil Brazilian ? www.tqs.com.br/v13/alvest.htm

    Tricalc.13 Spain Eurocode FEM www.arktec.com/new_t13.htm

    Tricalc.17 Spain Spanish FEM www.arktec.com/new_t17.htm

    WinMason USA USA Storey Mech. www.archonengineering.com/winmason.html

    3DMacro Italy Italian SCM http://www.3dmacro.it/

    3Muri Italy Italian SCM www.stadata.com

    ANDILWall Italy Italian SCM www.crsoft.it/andilwall

    MURATS Italy Italian Storey Mech. www.softwareparadiso.it/murats.htm

    Sismur Italy Italian Storey Mech. www.franiac.it/sismur.html

    TRAVILOG Italy Italian Storey Mech. www.logical.it/software_travilog.aspx

    Tecnobit Italy Italian Storey Mech. www.tecnobit.info/products/murature.php

    CDMaWin Italy Italian FEM and SCM www.stsweb.net/STSWeb/ITA/homepage.htm

    There is commercial software available for structural UR masonry, particularly

    in Italy. Benchmarking was made in two publications: Azores 1998, Eds. C.

    Sousa Oliveira et al., (2008) and Marques, R., Loureno, P.B., Possibilities and comparison of structural component models for the seismic assessment of

    masonry buildings, Computers and Structures, 89 (21-22), p. 2079-2091 (2011)

    Commercial Software (I)

  • Institute for Sustainability and Innovation in Structural Engineering

    35 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Efficient and high level modeling

    Commercial Software (II)

  • Institute for Sustainability and Innovation in Structural Engineering

    36 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Displacement Based Design

    Recent methods implement capacity/displacement-based seismic design, by evaluating the evolution of damage and displacement

    Structural

    objects

    Geometric

    definition

    Structural

    characteristics

    DXF/DWG

    Automatic

    mesh definition

    Equivalent

    mesh/frame definition

    A Displacement

    capacity

    B Displacement

    demand

    Final analysis

    Non-linear

    analysis

    Seismic

    parameters

    0

    100

    200

    300

    400

    500

    0 10 20 30 40

    Displacement (mm)

    Ba

    se

    sh

    ea

    r (

    kN

    )

    If the damage evolution can be used as a measure of seismic

    performance, the confrontation

    between displacement capacity

    and displacement demand is the

    rule for safety verification

  • Institute for Sustainability and Innovation in Structural Engineering

    37 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    In a force based method, the non-linear reserve capacity must be considered

    For unreinforced masonry

    buildings with 2 or more storeys:

    EC8:

    q = 1.5-2.5 (recommended 1.5)

    OPCM 3431:

    u /1 (OSR) = 1.8

    q = q0 x OSR = 3.6

    Energy Dissipation Capacity (I)

  • Institute for Sustainability and Innovation in Structural Engineering

    38 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Energy Dissipation Capacity (II)

  • Institute for Sustainability and Innovation in Structural Engineering

    39 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    necessrio ter em conta a reserva de capacidade no linear das estruturas em ductilidade

    Para edifcios em alvenaria simples com 2 ou mais pisos:

    EC8:

    q(0) = 2.0

    OPCM 3431:

    u /1 (OSR) = 1.8

    q = q0 x OSR = 3.6

    Energy Dissipation Capacity (III)

  • noitacilppA

  • Institute for Sustainability and Innovation in Structural Engineering

    41 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    PARAMETRIC STUDY on the NR. of STOREYS (I)

    6.5

    0

    6.50

    1.50 1.00 1.50 1.00 1.50

    3.0

    0

    2.0

    0

    0.30

    6.5

    0

    6.50

    1.50 1.00 1.50 1.00 1.50

    6.0

    0

    2.0

    01.0

    0

    0.30

    6.5

    0

    6.50

    1.50 1.00 1.50 1.00 1.50

    9.0

    0

    2.0

    01.0

    01.0

    0

    0.30

    Dead load = 6.0 kN/m2

    Live load = 1.5 kN/m2

    Dead load = 6.0 kN/m2

    Live load = 1.0 kN/m2

    Dl = 7.0 kN/m2; Ll = 2.0 kN/m2

    Dl = 6.0 kN/m2; Ll = 1.0 kN/m2

    Dl = 7.0 kN/m2; Ll = 2.0 kN/m2

    Dl = 7.0 kN/m2; Dl = 2.0 kN/m2

    Undamaged Plastic by shear Failure by shear Plastic by flexural Failure by flexural

    Specific weight , 17.0 kN/m3

    Compressive characteristic strength , fk 2.56 MPa

    Sliding pure shear characteristic strength, fvk0 0.15 MPa

    Normal elasticity module, E 2560 MPa

    Tangential elasticity module, G 1024 MPa

  • Institute for Sustainability and Innovation in Structural Engineering

    42 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    agR(m/s2) S

    A

    B

    A

    B

    A

    B

    Soil

    1.00

    1.35

    1.00

    1.33

    1.00

    1.35

    1.70

    1.10

    0.80

    2.3

    Zone

    2.4

    2.5

    agR (m/s2) S

    A

    B

    A

    B

    A

    B

    A

    B

    A

    B

    Soil

    1.00

    1.20

    1.00

    1.20

    1.00

    1.20

    1.00

    1.30

    1.00

    1.30

    2.50

    2.00

    1.50

    1.00

    0.50

    1.3

    Zone

    1.2

    1.1

    1.4

    1.5

    agR(m/s2) S

    A

    B

    A

    B

    A

    B

    Soil

    1.00

    1.35

    1.00

    1.33

    1.00

    1.35

    1.70

    1.10

    0.80

    2.3

    Zone

    2.4

    2.5

    agR (m/s2) S

    A

    B

    A

    B

    A

    B

    A

    B

    A

    B

    Soil

    1.00

    1.20

    1.00

    1.20

    1.00

    1.20

    1.00

    1.30

    1.00

    1.30

    2.50

    2.00

    1.50

    1.00

    0.50

    1.3

    Zone

    1.2

    1.1

    1.4

    1.5

    Elastic Analysis ac. PT NA to EC8 (q=1.5)

    Unsafe Safe in soil type A Safe in soil types A and B

    Pushover Analysis

    OSRqF

    Fqq

    el

    y

    00

    Elastic Analysis ac. IT OPCM 3431

    agR(m/s2) S

    A

    B

    A

    B

    A

    B

    Soil

    1.00

    1.35

    1.00

    1.33

    1.00

    1.35

    1.70

    1.10

    0.80

    2.3

    Zone

    2.4

    2.5

    agR (m/s2) S

    A

    B

    A

    B

    A

    B

    A

    B

    A

    B

    Soil

    1.00

    1.20

    1.00

    1.20

    1.00

    1.20

    1.00

    1.30

    1.00

    1.30

    2.50

    2.00

    1.50

    1.00

    0.50

    1.3

    Zone

    1.2

    1.1

    1.4

    1.5

    agR(m/s2) S

    A

    B

    A

    B

    A

    B

    Soil

    1.00

    1.35

    1.00

    1.33

    1.00

    1.35

    1.70

    1.10

    0.80

    2.3

    Zone

    2.4

    2.5

    agR (m/s2) S

    A

    B

    A

    B

    A

    B

    A

    B

    A

    B

    Soil

    1.00

    1.20

    1.00

    1.20

    1.00

    1.20

    1.00

    1.30

    1.00

    1.30

    2.50

    2.00

    1.50

    1.00

    0.50

    1.3

    Zone

    1.2

    1.1

    1.4

    1.5

    Elastic Analysis ac. PT NA to EC8 (q=1.5)

    Pushover Analysis

    PARAMETRIC STUDY on the NR. of STOREYS (II)

  • Masonry

    Structures

    Without Box

    Behavior

  • Institute for Sustainability and Innovation in Structural Engineering

    44 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Recent Tests: Flexible Diaphragm

    Gaioleiro-type structure (late 19th century / early 20th century)

    Moderate damage for 100% of the design earthquake in Lisbon

    Light strengthening and collapse for 150% of the design earthquake in Lisbon

  • Institute for Sustainability and Innovation in Structural Engineering

    45 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Location: New Delhi (India)

    Material: Masonry

    Total Height: 72.5 m

    Crosss section: shell (3 leaves) + core (2 leaves)

    71.4

    8

    28.9

    615.3

    912.4

    27.7

    36.9

    8

    14.07

    3.13Qutb Minar

  • Institute for Sustainability and Innovation in Structural Engineering

    46 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Beam FEM

    UMinho

    FEM

    UPadova

    FEM

    CBRI

    0.0

    1.0

    2.0

    3.0

    4.0

    5.0

    6.0

    7.0

    0 1 2 3 4 5 6 7

    Calculated Frequencies [Hz]E

    xp

    eri

    men

    tal F

    req

    uen

    cie

    s [

    Hz]

    Experimental

    FEM - UMinho

    FEM - UPadova

    FEM - CBRI

    BEAM

    REM

    Bending

    Bending

    Bending

    Torsion

    Bending

    Axial

    Rigid

    Blocks

    Calibration

    Numerical Modeling

  • Institute for Sustainability and Innovation in Structural Engineering

    47 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Collapse at the base

    Uniform Mass Distribution

    Push-Over Analysis

    Other Mass Distributions

    0.00

    0.05

    0.10

    0.15

    0.20

    0.25

    0.0 0.2 0.4 0.6 0.8 1.0 1.2

    Lo

    ad

    Fa

    cto

    r

    Top Displacement [m]

    Beam model

    Rigid model

    Solid model

    D$formada Dinamica minar$t$accct$

    Fac. $scala: 5.00000 Paso 1810 Rigid - Plot V3.2.1

    0.00

    0.05

    0.10

    0.15

    0.20

    0.25

    0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8

    Lateral displacement [m]

    Lo

    ad

    fa

    cto

    r [

    ba

    se s

    hea

    r /

    self

    -wei

    gh

    t]

    Mass Proportional

    Linear Proportional

    1 Mode proportional

  • Institute for Sustainability and Innovation in Structural Engineering

    48 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    -0.8

    -0.7

    -0.6

    -0.5

    -0.4

    -0.3

    -0.2

    -0.1

    0

    0.1

    0.2

    0.3

    0.4

    0 5 10 15 20 25

    Tempo [s]

    Deslo

    cam

    en

    to h

    ori

    zo

    nta

    l [m

    ]

    5 balco

    4 balco

    3 balco

    2 balco

    1 balco

    Collapse: 4th

    balcony

    -2.0

    -1.5

    -1.0

    -0.5

    0.0

    0.5

    1.0

    1.5

    2.0

    0 5 10 15 20

    Time [s]

    Ac

    ce

    lera

    tio

    n [

    m/s

    2]

    0.0

    0.1

    0.2

    0.3

    0.4

    0.5

    0.6

    0 0.5 1 1.5 2

    Period [s]

    Seis

    mic

    co

    eff

    icie

    nt

    Ah

    DBERecord 1Record 2Record 3Record 4Record 5Srie7Srie8Srie9

    Second mode 0.50

    10th mode

    0.16First mode 1.26

    0

    10

    20

    30

    40

    50

    60

    70

    0 50 100 150 200 250 300

    Maximum excentricity

    (Bending Moment / Axial Load )

    H [

    m]

    Record 1Record 2Record 3Record 4Record 5Srie6Srie7

    FEM Collapse for 0.20g

    Five articificial accelerograms

    REM

    Time History Analysis

  • Institute for Sustainability and Innovation in Structural Engineering

    49 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Location: Lisboa

    Material: Masonry walls and

    timber pavements

    No. of storeys: 4 to 6

    Numerical model

    Gaioleiro Building

  • Institute for Sustainability and Innovation in Structural Engineering

    50 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Gaioleiro Building

  • Institute for Sustainability and Innovation in Structural Engineering

    51 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Transversal Direction

    0

    0.05

    0.1

    0.15

    0.2

    0.25

    0.3

    0 0.01 0.02 0.03 0.04 0.05

    Deslocamento [m]

    Fact

    or

    de

    carg

    a (

    )

    0

    0.05

    0.1

    0.15

    0.2

    0.25

    0.3

    0 0.01 0.02 0.03 0.04 0.05

    Displacement [m]

    Sei

    smic

    coef

    fici

    ent

    [h]

    Pushover_1st ModePushover_MassDynamic

    0

    0.2

    0.4

    0.6

    0.8

    1

    0 0.005 0.01 0.015 0.02

    Deslocamento [m]

    Fact

    or

    de

    carg

    a [

    ]

    0

    0.2

    0.4

    0.6

    0.8

    1

    0 0.005 0.01 0.015 0.02

    Displacement [m]

    Sei

    smic

    coef

    fici

    ent

    [h]

    Pushover_1st ModePushover_MassDynamic

    Longitudinal Direction

    Pushover Analysis

  • Institute for Sustainability and Innovation in Structural Engineering

    52 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Numerical model

    Principal strains

    (external surface)

    1 [m/m]

    Experimental model Time History Analysis

  • Institute for Sustainability and Innovation in Structural Engineering

    53 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Design and Assessment = Macro-block analysis?

    Limit equilibrium analysis using the principle of virtual work is currently understood as the best analysis technique

    Overturning

  • snoisulcnoC

  • Institute for Sustainability and Innovation in Structural Engineering

    55 | Types of analysis: Linear static, linear dynamic and non linear static Paulo B. Loureno

    Conclusions Design and assessment methods based on non-linear analysis should be

    used for masonry structures. Linear elastic analysis methods (application of

    equivalent static forces and modal superposition) are questionable

    Adequate models and commercial software, based on pushover analysis, are available for masonry with box behavior

    It was shown that pushover analyses do not simulate correctly the failure mode of masonry structures without box behavior, meaning that higher

    vibration modes have a significant contribution

    Pushover analysis proportional to the mass are probably the best solution is global structural analysis models are used

    For design purposes, particularly for strengthening design, macro-block limit analysis is probably the best analysis tool for practitioners

    More research needs to be done in the field of masonry structures without box behavior and earthquakes