26
1 A compact Silicon-Tungsten- Scintillator ECAL? Graham W. Wilson Univ. of Kansas Cornell Workshop, July 13 th 2003

1 A compact Silicon-Tungsten-Scintillator ECAL? Graham W. Wilson Univ. of Kansas Cornell Workshop, July 13 th 2003

  • View
    216

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 1 A compact Silicon-Tungsten-Scintillator ECAL? Graham W. Wilson Univ. of Kansas Cornell Workshop, July 13 th 2003

1

A compact Silicon-Tungsten-Scintillator

ECAL?

Graham W. Wilson

Univ. of Kansas

Cornell Workshop, July 13th 2003

Page 2: 1 A compact Silicon-Tungsten-Scintillator ECAL? Graham W. Wilson Univ. of Kansas Cornell Workshop, July 13 th 2003

2

Outline

• Introduction• (Parametric Energy Flow Study -> Tuesday)• ECAL Design issues :

Simulation studies of :i) Light collection uniformity in tile-fiberii) EM energy resolution

• Strawman ECAL design• Hardware activities

Page 3: 1 A compact Silicon-Tungsten-Scintillator ECAL? Graham W. Wilson Univ. of Kansas Cornell Workshop, July 13 th 2003

3

Big picture

• Electromagnetic calorimetry critical for separating photon-hadron separation in p-flow jet energy measurement

• ECAL cost likely to be a major issue– Need to justify various options in terms of

performance and cost– Explore alternatives

• If B R2/RM is the FoM, a compact design (small RM) which we can afford to place at large B R2 is interesting

Page 4: 1 A compact Silicon-Tungsten-Scintillator ECAL? Graham W. Wilson Univ. of Kansas Cornell Workshop, July 13 th 2003

4

ECAL requirements• Reasonable performance on single particle figures of merit :

– Energy resolution : 10%/E 1%

– Angular resolution : 1 mrad

• Hermetic – measurement of missing energy very important.

• Contribute to excellent jet energy resolution. Aim for 30%/ E.

– Essential to separate photons from interacting charged hadrons

– Higher B, higher R2, smaller Moliere radius (transverse size)

– So large volume, compact and dense

• Timing resolution.

– Bunch crossings potentially every 1.4 ns.

– Time resolution of 300 ps for photons helps

• Affordable.

Page 5: 1 A compact Silicon-Tungsten-Scintillator ECAL? Graham W. Wilson Univ. of Kansas Cornell Workshop, July 13 th 2003

5

Tungsten-Silicon ECAL• Proposals exist for W-Si ECAL. • The TESLA design, R=1.7m, 40 layers of

Silicon pads looks as if it can do the job (except maybe the timing), but is costed at 133 M$ (driven by 3$/cm2 Si cost)– Eres = 11%/E , Moliere radius = 16.5 mm

• Our proposal centers on developing a cost optimized ECAL, with similar performance. This hybrid calorimeter would use Silicon sensors to do the fine pattern recognition and position measurement, plastic scintillators for fine sampling and timing.– TILE-HCAL aim 10$/tile 0.4 $/cm2 (25 cm2area)– 1.0 $/cm2 (10 cm2area)

Sc-W-Sc-W-Si-W-Sc-W-Sc-W

Page 6: 1 A compact Silicon-Tungsten-Scintillator ECAL? Graham W. Wilson Univ. of Kansas Cornell Workshop, July 13 th 2003

6

Tile/fiber technique

Use blue scintillator.

Embed wavelength shifting fiber which absorbs blue scintillation light, re-emits in the green.

(Y11 absorption length : 80 m)

Min. bending : 100 fiber

Several fibers can be seen by one photo-detector

(CMS photo)

Page 7: 1 A compact Silicon-Tungsten-Scintillator ECAL? Graham W. Wilson Univ. of Kansas Cornell Workshop, July 13 th 2003

7

Recent developments• Excellent light-yield for tile-fiber reported by CALICE TILE-HCAL

(V Korbel, Jeju 02)

– 25 pe/mip with 5mm Scintillator, QE15% PMT

• Higher QE devices (eg. APD) promise QE75% and ease of use in B-field

– up to 20 pe/mip/mm looks possible

• Elegant and cheap “on-tile” optical readout possibilities – Silicon

PM’s => maybe 10$/tile cost Recent technique refinements suggest :

I) can detect mips in each layer (if necessary)

II) scintillator sampling is much more likely to be significantly cheaper than silicon sampling

III) A more compact ECAL with scintillator sampling can be envisaged

Page 8: 1 A compact Silicon-Tungsten-Scintillator ECAL? Graham W. Wilson Univ. of Kansas Cornell Workshop, July 13 th 2003

8

Amsterdam workshop• Discussions with Stan

Bentvelsen (NIKHEF)• Picked up a OPAL

tile-endcap complete tile assembly

• Stan helped get us started looking at GEANT4 simulation of tile response (he did similar GEANT3 studies for the OPAL design)

Page 9: 1 A compact Silicon-Tungsten-Scintillator ECAL? Graham W. Wilson Univ. of Kansas Cornell Workshop, July 13 th 2003

9

GEANT4 study of tile-fiber response

WIRED display of one photon rattling around in a perfect tile.

Uses optical photon processes – exampleN06. Includes scintillation, Cerenkov radiation, Rayleigh scattering, absorption, Fresnel refraction, TI reflection.

Data runs saved with AIDA, analyzed in JAS3, looking at light yield, uniformity, timing, spectral characteristics.

Study is making progress – but results not yet mature.

Shopping list : Real data !, validate implementation (eg. Reflectivity,WLS properties). Anyone tried something similar?

with Eric Benavidez

Page 10: 1 A compact Silicon-Tungsten-Scintillator ECAL? Graham W. Wilson Univ. of Kansas Cornell Workshop, July 13 th 2003

10

ECAL Design Studies• This spring – had looked at conceptual design issues of

sampling frequency, sampling thickness and compactness in the framework of estimates based on parametrisations available in the literature expected to be good to around 10%.– Eg. Eres = 2.7% [tactive(mm)/fsamp] (Wigmans p190) (labelled

WPAR in next plots)

• Now using GEANT4 to repeat those studies and investigate actual hybrid geometries. GEANT4 results sensitive to range cut.

• Despite “EM showers are understood mantra”, is there really good data in the literature which can be used to test/benchmark GEANT4 sampling ECAL results ?

Page 11: 1 A compact Silicon-Tungsten-Scintillator ECAL? Graham W. Wilson Univ. of Kansas Cornell Workshop, July 13 th 2003

11

ECAL Design Issues : Sampling Frequency

Issues : cost of many layers of active medium

Cost of thin sheets of absorber.

Dense medium like Si has high sampling fraction

WPAR WPAR

Page 12: 1 A compact Silicon-Tungsten-Scintillator ECAL? Graham W. Wilson Univ. of Kansas Cornell Workshop, July 13 th 2003

12

ECAL Design Study : Sampling Thickness

For thin scintillators, need enough photo-electron statistics. (Kawagoe et al, 3.2pe for 1mm scintillator)

1.5 pe/mip/mm looks like a sensible target for thin tiles

WPARWPAR

Page 13: 1 A compact Silicon-Tungsten-Scintillator ECAL? Graham W. Wilson Univ. of Kansas Cornell Workshop, July 13 th 2003

13

Compactness

Need to minimise gaps, reduce space needed for fiber routing, by sharing fiber routing gaps among layers

Lower curves, no gap

Upper curves, 1mm gap

TESLA TDR

Assume 25% of scintillator thickness used for readout

Page 14: 1 A compact Silicon-Tungsten-Scintillator ECAL? Graham W. Wilson Univ. of Kansas Cornell Workshop, July 13 th 2003

14

New studies

• All calorimeter designs have 30 X0 of W (105 mm) to ensure adequate longitudinal containment and a fair comparison.

• GEANT4 studies are done primarily with 1 GeV photons (which are definitely longitudinally contained)

with Eric Benavidez (freshman)

Page 15: 1 A compact Silicon-Tungsten-Scintillator ECAL? Graham W. Wilson Univ. of Kansas Cornell Workshop, July 13 th 2003

15

Scintillator-Tungsten Calorimeter

1.4mm W plates (75 layers) GEANT4 study based on TestEm3 example.

3 curves correspond to range cuts of 100, 10, 1 m (from top to bottom)

Sampling contribution onlyNB differs substantially from WPAR estimate

1 GeV photon

Page 16: 1 A compact Silicon-Tungsten-Scintillator ECAL? Graham W. Wilson Univ. of Kansas Cornell Workshop, July 13 th 2003

16

Comparison (75 layers)

WPARGEANT4

Focus just on the lowest line in both

NB WPAR studies suggested E-res indep. of thickness. Not with G4.

Page 17: 1 A compact Silicon-Tungsten-Scintillator ECAL? Graham W. Wilson Univ. of Kansas Cornell Workshop, July 13 th 2003

17

Range cuts• 1 m range cut is sufficient to estimate resolution

with 2-3% accuracy. This corresponds to cutoffs of 1.6 and 8.9 keV for and e in Tungsten

• However, the EM response still requires basically no cut (0.1 m setting)

• (Sc/W 1.5mm/1.4mm), 1 GeV photon• 100 m: 47.8 MeV, 11.6%• 10 m: 50.5 MeV, 10.7% • 1 m: 55.7 MeV, 10.4%• 0.1 m: 63.5 MeV, 10.2%

Page 18: 1 A compact Silicon-Tungsten-Scintillator ECAL? Graham W. Wilson Univ. of Kansas Cornell Workshop, July 13 th 2003

18

PE stats contribution: 2.5, 5.0, 10.0, 20.0 pe/mip/mm

E-resolution dependence on P.E. statistics

N.B. Suppressed zero

Sampling contribution

PE stats contribution: 2.5, 5.0, 10.0, 20.0 pe/mip/mm

Total: sampling PE stats (2.5, 5, 10, 20 pe/mip/mm)

Lower curve : sampling only

GEANT4 (1m range cut)

For 5 pe/mip/mm, at t=1.5mm degrades from 10.5% to 10.9%

1.4mm W plates 1.4mm W plates

Page 19: 1 A compact Silicon-Tungsten-Scintillator ECAL? Graham W. Wilson Univ. of Kansas Cornell Workshop, July 13 th 2003

19

Three strawman hybrid designs

HY75 (15 SL) HY135 (15 SL) HY42 (14 SL)

Sc-W-Sc-W-Si-W-Sc-W-Sc-W

A super-layer (SL)

In each case the Si layer is chosen as 400 m Si + 2.0 mm G10 as in SDMar01 detector

Studied with GEANT4 (range cut = 1 m)

So far: study uniform sampling structures.

Page 20: 1 A compact Silicon-Tungsten-Scintillator ECAL? Graham W. Wilson Univ. of Kansas Cornell Workshop, July 13 th 2003

20

HY75 HY135 HY42• 1.4mm W plates• 15 layers Si• 60 layers of

1.5mm Scint.• 4 layers ganged

(30 pe/mip) ( if 5pe/mip/mm)

• 15 super-layers each with mip-detection

• 0.778mm W plates• 15 layers Si• 120 layers of 1mm

Sc• 8 layers ganged

(40 pe/mip)• 15 super-layers

E res : 10.6%/E 7.9%/E 14.5%/ E

Moliere radius : 19.3 mm 21.4 mm 16.5 mm

33% of the Silicon cost

(SDMar01 30X0 W : 15.4%/E, 15.5 mm with 0.1 m range cut)

• 2.5 mm W plates• 14 layers Si• 28 layers of 2 mm

Sc• 2 layers ganged

(20 pe/mip)• 14 super-layers

Page 21: 1 A compact Silicon-Tungsten-Scintillator ECAL? Graham W. Wilson Univ. of Kansas Cornell Workshop, July 13 th 2003

21

Complementarity - Correlations

Correlation coefficient = -0.19

HY135 : 7.9% E-resolution

Correlation improves resolution

slightly – compensates for PE stats

Page 22: 1 A compact Silicon-Tungsten-Scintillator ECAL? Graham W. Wilson Univ. of Kansas Cornell Workshop, July 13 th 2003

22

Linearity check

• Check HY75 with 50 GeV and 1 GeV • Study done with 100 m range cut (need to

recheck)• EM response consistent : Scint. Fraction : 3.78%

(50), 3.77% (1)• Sc/Si response consistent: 1.861 (50), 1.865 (1)• E-res consistent : 12.1%/E (50), 12.0%/E (1)• Corr. Coeff. : -0.14 (50), -0.13 (1)

Page 23: 1 A compact Silicon-Tungsten-Scintillator ECAL? Graham W. Wilson Univ. of Kansas Cornell Workshop, July 13 th 2003

23

Possible photo-detectorsHamamatsu, multi-anode PMT, with 18mm18mm sensitive area.

16-channels has 164.5 4.5mm (16 1mm fibers)

64-channels has 64 2.25 2.25 mm (4 1mm fibers)

Makes optical summing of several layers easy

B-field sensitivity and modest Q.E. – probably not the real detector solution.

Page 24: 1 A compact Silicon-Tungsten-Scintillator ECAL? Graham W. Wilson Univ. of Kansas Cornell Workshop, July 13 th 2003

24

Hardware plans

• Planning VME-based DAQ for cosmic and source tests, particularly for uniformity and light yield studies.

• Basics ordered – including ADCs, discriminators and TDCs.

• Start getting experience with tile-fiber technique and various photo-detectors.

Page 25: 1 A compact Silicon-Tungsten-Scintillator ECAL? Graham W. Wilson Univ. of Kansas Cornell Workshop, July 13 th 2003

25

Potential Collaborators

• Kansas State: E. von Toerne, T. Bolton– Plan to collaborate

• Colorado: Uriel et al– Lots in common – talking to each other

• Padova, INFN : P. Checchia et al.– Discussed in Amsterdam – some commonalities

• CALICE : JC Brient. Thin Sc/W/Sc elements conforming to alveolus structure can be accommodated in Si-W test beam

• US Si-W groups: Oregon, SLAC• TILE-HCAL groups : DESY, Russia, NIU• Japanese ECAL : in contact with Kawagoe, Fujii,

Takeshita

Page 26: 1 A compact Silicon-Tungsten-Scintillator ECAL? Graham W. Wilson Univ. of Kansas Cornell Workshop, July 13 th 2003

26

R&D issues• Calorimeter design optimization.

– No. of layers, R, absorber thickness, detector thickness, sampling frequency vs depth, transverse granularity of Si/Sc, tile shapes, groove patterns, gap sizes. Should Si-layer be independent of scintillator layers ? Fiber routing. Timing resolution.

– Studying with full shower simulation. – Using optics simulation in tile-fiber design and testing studies.

• Demonstrating basic performance characteristics– Light yield for thin scintillating tiles– Response uniformity– Scintillator/WLS/Photo-detector for timing– Fiber routing for compact calorimeter– Sound mechanical design– Good quality thin absorber plates (sintering is cheap ..)– Photo-detector characteristics

Getting started with lab test-stand with cosmic rays and sources. Good for involving students.