Upload
others
View
4
Download
0
Embed Size (px)
Citation preview
ISSUED DATE DETAIL NUMBER
STANDARD ASSEMBLY - THERMOPLASTIC 2150 - TP - A1
[HG 3310] PROTECTIVE FLEECE
[HG 3195] INTENSIVE GEOFOAM INSULATION
STRUCTURAL METAL DECK
CONDUCTIVE MEDIUM (as required)
COVER BOARD, ADHERED
VAPOR RETARDER (as required)
ROOF SHEATHING
[HG 3160] PVC WATERPROOFING
[HG 6504] PRE-VEGETATED MODULE - 4"
4"
NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. Additional combinations of vegetated roof components are possible to meet specific project requirements.4. Contact Hanging Gardens for variations to the standard assembly.5. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.
STORMWATER RETENTION:·· 1.40 gallons / ft2
·· 2.24 in3 / in2
SATURATED WEIGHT:·· 29.47 lbs / ft2
·· 143.88 kg / m2
ROOF PITCH:·· 0 - 5o
·· 0 - 9%
01/01/19
STANDARD ASSEMBLY - THERMOPLASTICSCALE: 1 1/2" = 1'-0"1
[OTHERS] HEAVY DUTY UV RESISTANT NYLON CABLE TIES
HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM
ISSUED DATE DETAIL NUMBER
GREEN ROOF TO BALLAST STONE 2150 - TP - B1
[HG 3310] PROTECTIVE FLEECE
[HG 3195] INTENSIVE GEOFOAM INSULATION
STRUCTURAL METAL DECK
CONDUCTIVE MEDIUM (as required)
COVER BOARD, ADHERED
ROOF SHEATHING
[HG 3160] PVC WATERPROOFING
[HG 6504] PRE-VEGETATED MODULE - 4"
4"
VAPOR RETARDER (as required)
[HG 3920] SLOTTED ALUMINUM EDGE (as required)
NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.
STORMWATER RETENTION:·· 1.40 gallons / ft2
·· 2.24 in3 / in2
SATURATED WEIGHT:·· 29.47 lbs / ft2
·· 143.88 kg / m2
ROOF PITCH:·· 0 - 5o
·· 0 - 9%
01/01/19
GREEN ROOF TO BALLAST STONESCALE: 1 1/2" = 1'-0"1
DECORATIVE BALLAST STONE, 1-112" MIN. DIAMETER
[OTHERS] HEAVY DUTY UV RESISTANT NYLON CABLE TIES
HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM
ISSUED DATE DETAIL NUMBER
[HG 6504] PRE-VEGETATED MODULE - 4"
4"
2150 - TP - C1
STORMWATER RETENTION:·· 1.40 gallons / ft2
·· 2.24 in3 / in2
ROOF PITCH:·· 0 - 5o
·· 0 - 9%
01/01/19
SCALE: 1 1/2" = 1'-0"1
[HG 3310] PROTECTIVE FLEECE
[HG 3195] INTENSIVE GEOFOAM INSULATION
STRUCTURAL METAL DECK
CONDUCTIVE MEDIUM (as required)
COVER BOARD, ADHERED
ROOF SHEATHING
[HG 3160] PVC WATERPROOFING
VAPOR RETARDER (as required)
POURED IN PLACE CONCRETE
[HG 3530] PEDESTRIAN PAVING DRAIN
NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.
GREEN ROOF TO POURED IN PLACE CONCRETE
GREEN ROOF TO POURED IN PLACE CONCRETE
SATURATED WEIGHT:·· 29.47 lbs / ft2
·· 143.88 kg / m2
HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM
[HG 3920] SLOTTED ALUMINUM EDGE (as required)
ISSUED DATE DETAIL NUMBER
GREEN ROOF TO ROOF DRAIN - BALLAST STONE 2150 - TP - D1
DECORATIVE BALLAST STONE, 1-112" MIN. DIAMETER
[HG 3310] PROTECTIVE FLEECE
[HG 3195] INTENSIVE GEOFOAM INSULATION
STRUCTURAL METAL DECK
CONDUCTIVE MEDIUM (as required)
COVER BOARD, ADHERED
ROOF SHEATHING
ROOF DRAIN WITH ADJUSTABLE EXTENSION
SPECIFIED SEALANT UNDER MEMBRANE AT CLAMPING RING
SPECIFIED FLASHING MEMBRANE, HOT-AIR WELDED
[HG 3160] PVC WATERPROOFING
[HG 6504] PRE-VEGETATED MODULE - 4"
4"
VAPOR RETARDER (as required)
[HG 3920] SLOTTED ALUMINUM EDGE (as required)
NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. Vapor retarder shall be sealed at roof penetration.4. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.
STORMWATER RETENTION:·· 1.40 gallons / ft2
·· 2.24 in3 / in2
SATURATED WEIGHT:·· 29.47 lbs / ft2
·· 143.88 kg / m2
ROOF PITCH:·· 0 - 5o
·· 0 - 9%
01/01/19
GREEN ROOF TO ROOF DRAIN - BALLAST STONESCALE: 1 1/2" = 1'-0"1
HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM
ISSUED DATE DETAIL NUMBER
GREEN ROOF TO DRAIN ACCESS BOX - BALLAST STONE 2150 - TP - D2
1' MIN
[HG 3920] SLOTTED ALUMINUM EDGE (as required)
DECORATIVE BALLAST STONE, 1-112" MIN. DIAMETER
[HG 3310] PROTECTIVE FLEECE
[HG 3195] INTENSIVE GEOFOAM INSULATION
STRUCTURAL METAL DECK
CONDUCTIVE MEDIUM (as required)
COVER BOARD, ADHERED
ROOF SHEATHING
SPECIFIED SEALANT UNDER MEMBRANE AT CLAMPING RING
SPECIFIED FLASHING MEMBRANE, HOT-AIR WELDED
[HG 3550] DRAIN ACCESS BOX
[HG 3160] PVC WATERPROOFING
[HG 6504] PRE-VEGETATED MODULE - 4"
4"
VAPOR RETARDER (as required)
ROOF DRAIN WITH ADJUSTABLE EXTENSION
NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. Vapor retarder shall be sealed at roof penetration.4. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.
STORMWATER RETENTION:·· 1.40 gallons / ft2
·· 2.24 in3 / in2
SATURATED WEIGHT:·· 29.47 lbs / ft2
·· 143.88 kg / m2
ROOF PITCH:·· 0 - 5o
·· 0 - 9%
01/01/19
GREEN ROOF TO DRAIN ACCESS BOX - BALLAST STONESCALE: 1 1/2" = 1'-0"1
HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM
ISSUED DATE DETAIL NUMBER
GREEN ROOF TO DRAIN ACCESS BOX 2150 - TP - D3
[HG 3310] PROTECTIVE FLEECE
[HG 3195] INTENSIVE GEOFOAM INSULATION
STRUCTURAL METAL DECK
CONDUCTIVE MEDIUM (as required)
COVER BOARD, ADHERED
ROOF SHEATHING
SPECIFIED SEALANT UNDER MEMBRANE AT CLAMPING RING
SPECIFIED FLASHING MEMBRANE, HOT-AIR WELDED
[HG 3550] DRAIN ACCESS BOX
[HG 3160] PVC WATERPROOFING
[HG 6504] PRE-VEGETATED MODULE - 4"
4"
VAPOR RETARDER (as required)
ROOF DRAIN WITH ADJUSTABLE EXTENSION
NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. Vapor retarder shall be sealed at roof penetration.4. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.
STORMWATER RETENTION:·· 1.40 gallons / ft2
·· 2.24 in3 / in2
SATURATED WEIGHT:·· 29.47 lbs / ft2
·· 143.88 kg / m2
ROOF PITCH:·· 0 - 5o
·· 0 - 9%
01/01/19
GREEN ROOF TO DRAIN ACCESS BOXSCALE: 1 1/2" = 1'-0"1
HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM
ISSUED DATE DETAIL NUMBER
GREEN ROOF TO CONCRETE PAVERS OVER DRAIN 2150 - TP - D4
[HG 3920] SLOTTED ALUMINUM EDGE (as required)
[HG 3310] PROTECTIVE FLEECE
[HG 3195] INTENSIVE GEOFOAM INSULATION
STRUCTURAL METAL DECK
CONDUCTIVE MEDIUM (as required)
COVER BOARD, ADHERED
ROOF SHEATHING
[HG 5100] PAVER PEDESTALS
[HG 5310] CONCRETE PAVERS
SPECIFIED FLASHING MEMBRANE,
HOT-AIR WELDED
SPECIFIED SEALANT UNDER MEMBRANE AT CLAMPING RING
[HG 3160] PVC WATERPROOFING
[HG 6504] PRE-VEGETATED MODULE - 4"
4"
VAPOR RETARDER (as required)
ROOF DRAIN WITH ADJUSTABLE EXTENSION
NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. Vapor retarder shall be sealed at roof penetration.4. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.
STORMWATER RETENTION:·· 1.40 gallons / ft2
·· 2.24 in3 / in2
SATURATED WEIGHT:·· 29.47 lbs / ft2
·· 143.88 kg / m2
ROOF PITCH:·· 0 - 5o
·· 0 - 9%
01/01/19
GREEN ROOF TO CONCRETE PAVERS OVER DRAINSCALE: 1 1/2" = 1'-0"1
HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM
ISSUED DATE DETAIL NUMBER
GREEN ROOF TO CONCRETE PAVERS 2150 - TP - P1
[HG 3310] PROTECTIVE FLEECE
[HG 3195] INTENSIVE GEOFOAM INSULATION
STRUCTURAL METAL DECK
CONDUCTIVE MEDIUM (as required)
COVER BOARD, ADHERED
ROOF SHEATHING
[HG 3160] PVC WATERPROOFING
[HG 6504] PRE-VEGETATED MODULE - 4"
4"
VAPOR RETARDER (as required)
[HG 3920] SLOTTED ALUMINUM EDGE (as required)
NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.
STORMWATER RETENTION:·· 1.40 gallons / ft2
·· 2.24 in3 / in2
SATURATED WEIGHT:·· 29.47 lbs / ft2
·· 143.88 kg / m2
ROOF PITCH:·· 0 - 5o
·· 0 - 9%
01/01/19
GREEN ROOF TO CONCRETE PAVERSSCALE: 1 1/2" = 1'-0"1
[HG 5100] PAVER PEDESTALS
[HG 5310] CONCRETE PAVERS
[HG 3320] SEMI-INTENSIVE PROTECTIVE FLEECE
HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM
ISSUED DATE DETAIL NUMBER
GREEN ROOF TO WOOD DECK TILES 2150 - TP - P2
[HG 3310] PROTECTIVE FLEECE
[HG 3195] INTENSIVE GEOFOAM INSULATION
STRUCTURAL METAL DECK
CONDUCTIVE MEDIUM (as required)
COVER BOARD, ADHERED
ROOF SHEATHING
[HG 3160] PVC WATERPROOFING
[HG 6504] PRE-VEGETATED MODULE - 4"
4"
VAPOR RETARDER (as required)
[HG 3920] SLOTTED ALUMINUM EDGE (as required)
NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.
STORMWATER RETENTION:·· 1.40 gallons / ft2
·· 2.24 in3 / in2
SATURATED WEIGHT:·· 29.47 lbs / ft2
·· 143.88 kg / m2
ROOF PITCH:·· 0 - 5o
·· 0 - 9%
01/01/19
GREEN ROOF TO WOOD DECK TILESSCALE: 1 1/2" = 1'-0"1
[HG 5100] PAVER PEDESTALS
[HG 5350] WOOD DECK TILES
[HG 3320] SEMI-INTENSIVE PROTECTIVE FLEECE
HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM
ISSUED DATE DETAIL NUMBER
GREEN ROOF TO PORCELAIN PAVERS 2150 - TP - P3
[HG 3310] PROTECTIVE FLEECE
[HG 3195] INTENSIVE GEOFOAM INSULATION
STRUCTURAL METAL DECK
CONDUCTIVE MEDIUM (as required)
COVER BOARD, ADHERED
ROOF SHEATHING
[HG 3160] PVC WATERPROOFING
[HG 6504] PRE-VEGETATED MODULE - 4"
4"
VAPOR RETARDER (as required)
[HG 3920] SLOTTED ALUMINUM EDGE (as required)
NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.
STORMWATER RETENTION:·· 1.40 gallons / ft2
·· 2.24 in3 / in2
SATURATED WEIGHT:·· 29.47 lbs / ft2
·· 143.88 kg / m2
ROOF PITCH:·· 0 - 5o
·· 0 - 9%
01/01/19
GREEN ROOF TO PORCELAIN PAVERSSCALE: 1 1/2" = 1'-0"1
[HG 5100] PAVER PEDESTALS
[HG 5360] PORCELAIN PAVERS
[HG 3320] SEMI-INTENSIVE PROTECTIVE FLEECE
HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM
ISSUED DATE DETAIL NUMBER
[HG 6504] PRE-VEGETATED MODULE - 4"
4"
2150 - TP - T1
STORMWATER RETENTION:·· 1.40 gallons / ft2
·· 2.24 in3 / in2
ROOF PITCH:·· 0 - 5o
·· 0 - 9%
01/01/19
SCALE: 1 1/2" = 1'-0"1
GREEN ROOF TO ARTIFICIAL TURF - AGGREGATE
NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. Artificial turf must be installed and seamed with adjacent pieces running in the same direction.4. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.
GREEN ROOF TO ARTIFICIAL TURF - AGGREGATE
[HG 5410] SKYE TURF
[HG 3530] PEDESTRIAN PAVING DRAIN
[HG 5423] VERSATILE DRAINAGE MAT
[OTHERS] TREATED WOOD / COMPOSITE NAILER BOARD
- SET 1" BELOW FINISHED FLOOR ELEVATION
[OTHERS] 1" STAINLESS STEEL NAIL - SPACED EVERY 1"
WASHED SILICA SAND / [HG 5431] ENVIROFILL - GREEN(APPROX 3 LBS/SF)
[HG 3310] PROTECTIVE FLEECE
[HG 3195] INTENSIVE GEOFOAM INSULATION
STRUCTURAL METAL DECK
CONDUCTIVE MEDIUM (as required)
COVER BOARD, ADHERED
ROOF SHEATHING
[HG 3160] PVC WATERPROOFING
VAPOR RETARDER (as required)
[HG 4620] DRAINAGE AGGREGATE
SATURATED WEIGHT:·· 29.47 lbs / ft2
·· 143.88 kg / m2
[HG 3920] SLOTTED ALUMINUM EDGE (as required)
[OTHERS] HEAVY DUTY UV RESISTANT NYLON CABLE TIES
HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM
ISSUED DATE DETAIL NUMBER
[HG 6504] PRE-VEGETATED MODULE - 4"
4"
2150 - TP - T2
STORMWATER RETENTION:·· 1.40 gallons / ft2
·· 2.24 in3 / in2
ROOF PITCH:·· 0 - 5o
·· 0 - 9%
01/01/19
SCALE: 1 1/2" = 1'-0"1
GREEN ROOF TO ARTIFICIAL TURF - INSULATION
NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. Artificial turf must be installed and seamed with adjacent pieces running in the same direction.4. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.
GREEN ROOF TO ARTIFICIAL TURF - INSULATION
[HG 5410] SKYE TURF
[HG 3530] PEDESTRIAN PAVING DRAIN
[HG 5423] VERSATILE DRAINAGE MAT
[OTHERS] TREATED WOOD / COMPOSITE NAILER BOARD
- SET 1" BELOW FINISHED FLOOR ELEVATION
[OTHERS] 1" STAINLESS STEEL NAIL - SPACED EVERY 1"
WASHED SILICA SAND / [HG 5431] ENVIROFILL - GREEN(APPROX 3 LBS/SF)
[HG 3193] GEOFOAM INSULATION
[HG 3310] PROTECTIVE FLEECE
[HG 3195] INTENSIVE GEOFOAM INSULATION
STRUCTURAL METAL DECK
CONDUCTIVE MEDIUM (as required)
COVER BOARD, ADHERED
ROOF SHEATHING
[HG 3160] PVC WATERPROOFING
VAPOR RETARDER (as required)
[HG 3920] SLOTTED ALUMINUM EDGE (as required)
[OTHERS] HEAVY DUTY UV RESISTANT NYLON CABLE TIES
SATURATED WEIGHT:·· 29.47 lbs / ft2
·· 143.88 kg / m2
HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM
ISSUED DATE DETAIL NUMBER
DECORATIVE BALLAST STONE, 1-112" MIN. DIAMETER
1' MIN
GREEN ROOF TO ROOF PENETRATION - BALLAST STONE 2150 - TP - V1
STAINLESS STEEL HOSE CLAMP & SEALANT
[HG 3310] PROTECTIVE FLEECE
[HG 3160] PVC WATERPROOFING
[HG 3195] INTENSIVE GEOFOAM INSULATION
STRUCTURAL METAL DECK
CONDUCTIVE MEDIUM (as required)
COVER BOARD, ADHERED
SPECIFIED FLASHING MEMBRANE, HOT-AIR WELDED
ROOF SHEATHING
ROOF PENETRATION
SPECIFIED BASE FLASHING, HOT-AIR WELDED
SPECIFIED FASTENER6" O.C. AROUND PENETRATION
[HG 6504] PRE-VEGETATED MODULE - 4"
4"
VAPOR RETARDER (as required)
[HG 3920] SLOTTED ALUMINUM EDGE (as required)
NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. All flashing shall extend up roof penetration at least to the height of the top of the surfacing.4. Vapor retarder shall be sealed at roof penetration.5. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.
STORMWATER RETENTION:·· 1.40 gallons / ft2
·· 2.24 in3 / in2
SATURATED WEIGHT:·· 29.47 lbs / ft2
·· 143.88 kg / m2
ROOF PITCH:·· 0 - 5o
·· 0 - 9%
01/01/19
GREEN ROOF TO ROOF PENETRATION - BALLAST STONESCALE: 1 1/2" = 1'-0"1
HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM
ISSUED DATE DETAIL NUMBER
8" MIN
GREEN ROOF TO ROOF PENETRATION 2150 - TP - V2
STAINLESS STEEL HOSE CLAMP & SEALANT
[HG 3310] PROTECTIVE FLEECE
[HG 3195] INTENSIVE GEOFOAM INSULATION
STRUCTURAL METAL DECK
CONDUCTIVE MEDIUM (as required)
COVER BOARD, ADHERED
SPECIFIED FLASHING MEMBRANE, HOT-AIR WELDED
ROOF SHEATHING
ROOF PENETRATION
SPECIFIED BASE FLASHING, HOT-AIR WELDED
SPECIFIED FASTENER 6" O.C. AROUND PENETRATION
[HG 3160] PVC WATERPROOFING
[HG 6504] PRE-VEGETATED MODULE - 4"
4"
VAPOR RETARDER (as required)
NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. All flashing shall extend up roof penetration a minimum of 8" above highest water line.4. Vapor retarder shall be sealed at roof penetration.5. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.
STORMWATER RETENTION:·· 1.40 gallons / ft2
·· 2.24 in3 / in2
SATURATED WEIGHT:·· 29.47 lbs / ft2
·· 143.88 kg / m2
ROOF PITCH:·· 0 - 5o
·· 0 - 9%
01/01/19
GREEN ROOF TO ROOF PENETRATIONSCALE: 1 1/2" = 1'-0"1
[OTHERS] HEAVY DUTY UV RESISTANT NYLON CABLE TIES
HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM
ISSUED DATE DETAIL NUMBER
1' MIN
GREEN ROOF TO PARAPET WALL - BALLAST STONE 2150 - TP - W1
4"
[HG 3310] PROTECTIVE FLEECE
[HG 3195] INTENSIVE GEOFOAM INSULATION
STRUCTURAL METAL DECK
CONDUCTIVE MEDIUM (as required)
COVER BOARD, ADHERED
ROOF SHEATHING
SPECIFIED FASTENER 12" O.C.
HOT-AIR WELD
[HG 3160] PVC WATERPROOFING
[HG 6504] PRE-VEGETATED MODULE - 4"
VAPOR RETARDER (as required)
NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. All flashing shall extend a minimum of 8" above highest water line.4. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.
STORMWATER RETENTION:·· 1.40 gallons / ft2
·· 2.24 in3 / in2
SATURATED WEIGHT:·· 29.47 lbs / ft2
·· 143.88 kg / m2
ROOF PITCH:·· 0 - 5o
·· 0 - 9%
01/01/19
GREEN ROOF TO PARAPET WALL - BALLAST STONESCALE: 1 1/2" = 1'-0"1
SPECIFIED FLASHING MEMBRANE
TO ACCEPTABLE SUBSTRATE
[HG 3920] SLOTTED ALUMINUM EDGE (as required)
DECORATIVE BALLAST STONE. 1-112" MIN. DIAMETER
[OTHERS] HEAVY DUTY UV RESISTANT NYLON CABLE TIES
HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM
ISSUED DATE DETAIL NUMBER
GREEN ROOF TO PARAPET WALL - CONCRETE PAVERS 2150 - TP - W2
4"
[HG 3310] PROTECTIVE FLEECE
[HG 3195] INTENSIVE GEOFOAM INSULATION
STRUCTURAL METAL DECK
CONDUCTIVE MEDIUM (as required)
COVER BOARD, ADHERED
[HG 3920] SLOTTED ALUMINUM EDGE (as required)
ROOF SHEATHING
SPECIFIED FASTENER 12" O.C.
HOT-AIR WELD
[HG 3160] PVC WATERPROOFING
[HG 6504] PRE-VEGETATED MODULE - 4"
VAPOR RETARDER (as required)
NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. All flashing shall extend a minimum of 8" above highest water line.4. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.
STORMWATER RETENTION:·· 1.40 gallons / ft2
·· 2.24 in3 / in2
SATURATED WEIGHT:·· 29.47 lbs / ft2
·· 143.88 kg / m2
ROOF PITCH:·· 0 - 5o
·· 0 - 9%
01/01/19
GREEN ROOF TO PARAPET WALL - CONCRETE PAVERS ON PEDESTALSSCALE: 1 1/2" = 1'-0"1
SPECIFIED FLASHING MEMBRANE
TO ACCEPTABLE SUBSTRATE
[HG 5100] PAVER PEDESTALS
[HG 5310] CONCRETE PAVERS
HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM
ISSUED DATE DETAIL NUMBER
GREEN ROOF TO PARAPET WALL - WOOD DECK TILES 2150 - TP - W3
4"
[HG 3310] PROTECTIVE FLEECE
[HG 3195] INTENSIVE GEOFOAM INSULATION
STRUCTURAL METAL DECK
CONDUCTIVE MEDIUM (as required)
COVER BOARD, ADHERED
[HG 3920] SLOTTED ALUMINUM EDGE (as required)
ROOF SHEATHING
SPECIFIED FASTENER 12" O.C.
HOT-AIR WELD
[HG 3160] PVC WATERPROOFING
[HG 6504] PRE-VEGETATED MODULE - 4"
VAPOR RETARDER (as required)
NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. All flashing shall extend a minimum of 8" above highest water line.4. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.
STORMWATER RETENTION:·· 1.40 gallons / ft2
·· 2.24 in3 / in2
SATURATED WEIGHT:·· 29.47 lbs / ft2
·· 143.88 kg / m2
ROOF PITCH:·· 0 - 5o
·· 0 - 9%
01/01/19
GREEN ROOF TO PARAPET WALL - WOOD DECK TILES ON PEDESTALSSCALE: 1 1/2" = 1'-0"1
SPECIFIED FLASHING MEMBRANE
TO ACCEPTABLE SUBSTRATE
[HG 5100] PAVER PEDESTALS
[HG 5350] WOOD DECK TILES
HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM
ISSUED DATE DETAIL NUMBER
GREEN ROOF TO PARAPET WALL - PORCELAIN PAVERS 2150 - TP - W4
4"
[HG 3310] PROTECTIVE FLEECE
[HG 3195] INTENSIVE GEOFOAM INSULATION
STRUCTURAL METAL DECK
CONDUCTIVE MEDIUM (as required)
COVER BOARD, ADHERED
[HG 3920] SLOTTED ALUMINUM EDGE (as required)
ROOF SHEATHING
SPECIFIED FASTENER 12" O.C.
HOT-AIR WELD
[HG 3160] PVC WATERPROOFING
[HG 6504] PRE-VEGETATED MODULE - 4"
VAPOR RETARDER (as required)
NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. All flashing shall extend a minimum of 8" above highest water line.4. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.
STORMWATER RETENTION:·· 1.40 gallons / ft2
·· 2.24 in3 / in2
SATURATED WEIGHT:·· 29.47 lbs / ft2
·· 143.88 kg / m2
ROOF PITCH:·· 0 - 5o
·· 0 - 9%
01/01/19
GREEN ROOF TO PARAPET WALL - PORCELAIN PAVERS ON PEDESTALSSCALE: 1 1/2" = 1'-0"1
SPECIFIED FLASHING MEMBRANE
TO ACCEPTABLE SUBSTRATE
[HG 5100] PAVER PEDESTALS
[HG 5360] PORCELAIN PAVERS
HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM
ISSUED DATE DETAIL NUMBER
GREEN ROOF TO PARAPET WALL 2150 - TP - W5
4"
[HG 3310] PROTECTIVE FLEECE
[HG 3195] INTENSIVE GEOFOAM INSULATION
STRUCTURAL METAL DECK
CONDUCTIVE MEDIUM (as required)
COVER BOARD, ADHERED
ROOF SHEATHING
SPECIFIED FASTENER 12" O.C.
HOT-AIR WELD
[HG 3160] PVC WATERPROOFING
[HG 6504] PRE-VEGETATED MODULE - 4"
VAPOR RETARDER (as required)
NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. All flashing shall extend a minimum of 8" above highest water line.4. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.
STORMWATER RETENTION:·· 1.40 gallons / ft2
·· 2.24 in3 / in2
SATURATED WEIGHT:·· 29.47 lbs / ft2
·· 143.88 kg / m2
ROOF PITCH:·· 0 - 5o
·· 0 - 9%
01/01/19
GREEN ROOF TO PARAPET WALLSCALE: 1 1/2" = 1'-0"1
SPECIFIED FLASHING MEMBRANE
TO ACCEPTABLE SUBSTRATE
[OTHERS] HEAVY DUTY UV RESISTANT NYLON CABLE TIES
HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM
ISSUED DATE DETAIL NUMBER
GREEN ROOF TO PARAPET WALL - CONCRETE PAVERS 2150 - TP - W6
4"
[HG 3310] PROTECTIVE FLEECE
[HG 3195] INTENSIVE GEOFOAM INSULATION
STRUCTURAL METAL DECK
CONDUCTIVE MEDIUM (as required)
COVER BOARD, ADHERED
[HG 3920] SLOTTED ALUMINUM EDGE (as required)
ROOF SHEATHING
SPECIFIED FASTENER 12" O.C.
HOT-AIR WELD
[HG 3160] PVC WATERPROOFING
[HG 6504] PRE-VEGETATED MODULE - 4"
VAPOR RETARDER (as required)
NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. All flashing shall extend a minimum of 8" above highest water line.4. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.
STORMWATER RETENTION:·· 1.40 gallons / ft2
·· 2.24 in3 / in2
SATURATED WEIGHT:·· 29.47 lbs / ft2
·· 143.88 kg / m2
ROOF PITCH:·· 0 - 5o
·· 0 - 9%
01/01/19
GREEN ROOF TO PARAPET WALL - CONCRETE PAVERSSCALE: 1 1/2" = 1'-0"1
SPECIFIED FLASHING MEMBRANE
TO ACCEPTABLE SUBSTRATE
[HG 5310] CONCRETE PAVERS
[HG 3530] PEDESTRIAN PAVING DRAIN
HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM