ISSUED DATE DETAIL NUMBER STANDARD ASSEMBLY - THERMOPLASTIC 2150 - TP - A1 [HG 3310] PROTECTIVE FLEECE [HG 3195] INTENSIVE GEOFOAM INSULATION STRUCTURAL METAL DECK CONDUCTIVE MEDIUM (as required) COVER BOARD, ADHERED VAPOR RETARDER (as required) ROOF SHEATHING [HG 3160] PVC WATERPROOFING [HG 6504] PRE-VEGETATED MODULE - 4" 4" NOTES: 1. Install pre-vegetated modules tight together per layout plan & water-in. 2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another. 3. Additional combinations of vegetated roof components are possible to meet specific project requirements. 4. Contact Hanging Gardens for variations to the standard assembly. 5. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary. STORMWATER RETENTION: ·· 1.40 gallons / ft 2 ·· 2.24 in 3 / in 2 SATURATED WEIGHT: ·· 29.47 lbs / ft 2 ·· 143.88 kg / m 2 ROOF PITCH: ·· 0 - 5 o ·· 0 - 9% 01/01/19 STANDARD ASSEMBLY - THERMOPLASTIC SCALE: 1 1/2" = 1'-0" 1 [OTHERS] HEAVY DUTY UV RESISTANT NYLON CABLE TIES HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM

1 ISSUED DATEDETAIL NUMBER HG 2150 - EXTENSIVE 4 SEDUM ...€¦ · [hg 5350] wood deck tiles [hg 3320] semi-intensive protective fleece hg 2150 - extensive 4" sedum tray system. issued

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 1 ISSUED DATEDETAIL NUMBER HG 2150 - EXTENSIVE 4 SEDUM ...€¦ · [hg 5350] wood deck tiles [hg 3320] semi-intensive protective fleece hg 2150 - extensive 4" sedum tray system. issued

ISSUED DATE DETAIL NUMBER

STANDARD ASSEMBLY - THERMOPLASTIC 2150 - TP - A1

[HG 3310] PROTECTIVE FLEECE

[HG 3195] INTENSIVE GEOFOAM INSULATION

STRUCTURAL METAL DECK

CONDUCTIVE MEDIUM (as required)

COVER BOARD, ADHERED

VAPOR RETARDER (as required)

ROOF SHEATHING

[HG 3160] PVC WATERPROOFING

[HG 6504] PRE-VEGETATED MODULE - 4"

4"

NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. Additional combinations of vegetated roof components are possible to meet specific project requirements.4. Contact Hanging Gardens for variations to the standard assembly.5. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.

STORMWATER RETENTION:·· 1.40 gallons / ft2

·· 2.24 in3 / in2

SATURATED WEIGHT:·· 29.47 lbs / ft2

·· 143.88 kg / m2

ROOF PITCH:·· 0 - 5o

·· 0 - 9%

01/01/19

STANDARD ASSEMBLY - THERMOPLASTICSCALE: 1 1/2" = 1'-0"1

[OTHERS] HEAVY DUTY UV RESISTANT NYLON CABLE TIES

HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM

Page 2: 1 ISSUED DATEDETAIL NUMBER HG 2150 - EXTENSIVE 4 SEDUM ...€¦ · [hg 5350] wood deck tiles [hg 3320] semi-intensive protective fleece hg 2150 - extensive 4" sedum tray system. issued

ISSUED DATE DETAIL NUMBER

GREEN ROOF TO BALLAST STONE 2150 - TP - B1

[HG 3310] PROTECTIVE FLEECE

[HG 3195] INTENSIVE GEOFOAM INSULATION

STRUCTURAL METAL DECK

CONDUCTIVE MEDIUM (as required)

COVER BOARD, ADHERED

ROOF SHEATHING

[HG 3160] PVC WATERPROOFING

[HG 6504] PRE-VEGETATED MODULE - 4"

4"

VAPOR RETARDER (as required)

[HG 3920] SLOTTED ALUMINUM EDGE (as required)

NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.

STORMWATER RETENTION:·· 1.40 gallons / ft2

·· 2.24 in3 / in2

SATURATED WEIGHT:·· 29.47 lbs / ft2

·· 143.88 kg / m2

ROOF PITCH:·· 0 - 5o

·· 0 - 9%

01/01/19

GREEN ROOF TO BALLAST STONESCALE: 1 1/2" = 1'-0"1

DECORATIVE BALLAST STONE, 1-112" MIN. DIAMETER

[OTHERS] HEAVY DUTY UV RESISTANT NYLON CABLE TIES

HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM

Page 3: 1 ISSUED DATEDETAIL NUMBER HG 2150 - EXTENSIVE 4 SEDUM ...€¦ · [hg 5350] wood deck tiles [hg 3320] semi-intensive protective fleece hg 2150 - extensive 4" sedum tray system. issued

ISSUED DATE DETAIL NUMBER

[HG 6504] PRE-VEGETATED MODULE - 4"

4"

2150 - TP - C1

STORMWATER RETENTION:·· 1.40 gallons / ft2

·· 2.24 in3 / in2

ROOF PITCH:·· 0 - 5o

·· 0 - 9%

01/01/19

SCALE: 1 1/2" = 1'-0"1

[HG 3310] PROTECTIVE FLEECE

[HG 3195] INTENSIVE GEOFOAM INSULATION

STRUCTURAL METAL DECK

CONDUCTIVE MEDIUM (as required)

COVER BOARD, ADHERED

ROOF SHEATHING

[HG 3160] PVC WATERPROOFING

VAPOR RETARDER (as required)

POURED IN PLACE CONCRETE

[HG 3530] PEDESTRIAN PAVING DRAIN

NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.

GREEN ROOF TO POURED IN PLACE CONCRETE

GREEN ROOF TO POURED IN PLACE CONCRETE

SATURATED WEIGHT:·· 29.47 lbs / ft2

·· 143.88 kg / m2

HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM

[HG 3920] SLOTTED ALUMINUM EDGE (as required)

Page 4: 1 ISSUED DATEDETAIL NUMBER HG 2150 - EXTENSIVE 4 SEDUM ...€¦ · [hg 5350] wood deck tiles [hg 3320] semi-intensive protective fleece hg 2150 - extensive 4" sedum tray system. issued

ISSUED DATE DETAIL NUMBER

GREEN ROOF TO ROOF DRAIN - BALLAST STONE 2150 - TP - D1

DECORATIVE BALLAST STONE, 1-112" MIN. DIAMETER

[HG 3310] PROTECTIVE FLEECE

[HG 3195] INTENSIVE GEOFOAM INSULATION

STRUCTURAL METAL DECK

CONDUCTIVE MEDIUM (as required)

COVER BOARD, ADHERED

ROOF SHEATHING

ROOF DRAIN WITH ADJUSTABLE EXTENSION

SPECIFIED SEALANT UNDER MEMBRANE AT CLAMPING RING

SPECIFIED FLASHING MEMBRANE, HOT-AIR WELDED

[HG 3160] PVC WATERPROOFING

[HG 6504] PRE-VEGETATED MODULE - 4"

4"

VAPOR RETARDER (as required)

[HG 3920] SLOTTED ALUMINUM EDGE (as required)

NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. Vapor retarder shall be sealed at roof penetration.4. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.

STORMWATER RETENTION:·· 1.40 gallons / ft2

·· 2.24 in3 / in2

SATURATED WEIGHT:·· 29.47 lbs / ft2

·· 143.88 kg / m2

ROOF PITCH:·· 0 - 5o

·· 0 - 9%

01/01/19

GREEN ROOF TO ROOF DRAIN - BALLAST STONESCALE: 1 1/2" = 1'-0"1

HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM

Page 5: 1 ISSUED DATEDETAIL NUMBER HG 2150 - EXTENSIVE 4 SEDUM ...€¦ · [hg 5350] wood deck tiles [hg 3320] semi-intensive protective fleece hg 2150 - extensive 4" sedum tray system. issued

ISSUED DATE DETAIL NUMBER

GREEN ROOF TO DRAIN ACCESS BOX - BALLAST STONE 2150 - TP - D2

1' MIN

[HG 3920] SLOTTED ALUMINUM EDGE (as required)

DECORATIVE BALLAST STONE, 1-112" MIN. DIAMETER

[HG 3310] PROTECTIVE FLEECE

[HG 3195] INTENSIVE GEOFOAM INSULATION

STRUCTURAL METAL DECK

CONDUCTIVE MEDIUM (as required)

COVER BOARD, ADHERED

ROOF SHEATHING

SPECIFIED SEALANT UNDER MEMBRANE AT CLAMPING RING

SPECIFIED FLASHING MEMBRANE, HOT-AIR WELDED

[HG 3550] DRAIN ACCESS BOX

[HG 3160] PVC WATERPROOFING

[HG 6504] PRE-VEGETATED MODULE - 4"

4"

VAPOR RETARDER (as required)

ROOF DRAIN WITH ADJUSTABLE EXTENSION

NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. Vapor retarder shall be sealed at roof penetration.4. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.

STORMWATER RETENTION:·· 1.40 gallons / ft2

·· 2.24 in3 / in2

SATURATED WEIGHT:·· 29.47 lbs / ft2

·· 143.88 kg / m2

ROOF PITCH:·· 0 - 5o

·· 0 - 9%

01/01/19

GREEN ROOF TO DRAIN ACCESS BOX - BALLAST STONESCALE: 1 1/2" = 1'-0"1

HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM

Page 6: 1 ISSUED DATEDETAIL NUMBER HG 2150 - EXTENSIVE 4 SEDUM ...€¦ · [hg 5350] wood deck tiles [hg 3320] semi-intensive protective fleece hg 2150 - extensive 4" sedum tray system. issued

ISSUED DATE DETAIL NUMBER

GREEN ROOF TO DRAIN ACCESS BOX 2150 - TP - D3

[HG 3310] PROTECTIVE FLEECE

[HG 3195] INTENSIVE GEOFOAM INSULATION

STRUCTURAL METAL DECK

CONDUCTIVE MEDIUM (as required)

COVER BOARD, ADHERED

ROOF SHEATHING

SPECIFIED SEALANT UNDER MEMBRANE AT CLAMPING RING

SPECIFIED FLASHING MEMBRANE, HOT-AIR WELDED

[HG 3550] DRAIN ACCESS BOX

[HG 3160] PVC WATERPROOFING

[HG 6504] PRE-VEGETATED MODULE - 4"

4"

VAPOR RETARDER (as required)

ROOF DRAIN WITH ADJUSTABLE EXTENSION

NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. Vapor retarder shall be sealed at roof penetration.4. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.

STORMWATER RETENTION:·· 1.40 gallons / ft2

·· 2.24 in3 / in2

SATURATED WEIGHT:·· 29.47 lbs / ft2

·· 143.88 kg / m2

ROOF PITCH:·· 0 - 5o

·· 0 - 9%

01/01/19

GREEN ROOF TO DRAIN ACCESS BOXSCALE: 1 1/2" = 1'-0"1

HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM

Page 7: 1 ISSUED DATEDETAIL NUMBER HG 2150 - EXTENSIVE 4 SEDUM ...€¦ · [hg 5350] wood deck tiles [hg 3320] semi-intensive protective fleece hg 2150 - extensive 4" sedum tray system. issued

ISSUED DATE DETAIL NUMBER

GREEN ROOF TO CONCRETE PAVERS OVER DRAIN 2150 - TP - D4

[HG 3920] SLOTTED ALUMINUM EDGE (as required)

[HG 3310] PROTECTIVE FLEECE

[HG 3195] INTENSIVE GEOFOAM INSULATION

STRUCTURAL METAL DECK

CONDUCTIVE MEDIUM (as required)

COVER BOARD, ADHERED

ROOF SHEATHING

[HG 5100] PAVER PEDESTALS

[HG 5310] CONCRETE PAVERS

SPECIFIED FLASHING MEMBRANE,

HOT-AIR WELDED

SPECIFIED SEALANT UNDER MEMBRANE AT CLAMPING RING

[HG 3160] PVC WATERPROOFING

[HG 6504] PRE-VEGETATED MODULE - 4"

4"

VAPOR RETARDER (as required)

ROOF DRAIN WITH ADJUSTABLE EXTENSION

NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. Vapor retarder shall be sealed at roof penetration.4. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.

STORMWATER RETENTION:·· 1.40 gallons / ft2

·· 2.24 in3 / in2

SATURATED WEIGHT:·· 29.47 lbs / ft2

·· 143.88 kg / m2

ROOF PITCH:·· 0 - 5o

·· 0 - 9%

01/01/19

GREEN ROOF TO CONCRETE PAVERS OVER DRAINSCALE: 1 1/2" = 1'-0"1

HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM

Page 8: 1 ISSUED DATEDETAIL NUMBER HG 2150 - EXTENSIVE 4 SEDUM ...€¦ · [hg 5350] wood deck tiles [hg 3320] semi-intensive protective fleece hg 2150 - extensive 4" sedum tray system. issued

ISSUED DATE DETAIL NUMBER

GREEN ROOF TO CONCRETE PAVERS 2150 - TP - P1

[HG 3310] PROTECTIVE FLEECE

[HG 3195] INTENSIVE GEOFOAM INSULATION

STRUCTURAL METAL DECK

CONDUCTIVE MEDIUM (as required)

COVER BOARD, ADHERED

ROOF SHEATHING

[HG 3160] PVC WATERPROOFING

[HG 6504] PRE-VEGETATED MODULE - 4"

4"

VAPOR RETARDER (as required)

[HG 3920] SLOTTED ALUMINUM EDGE (as required)

NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.

STORMWATER RETENTION:·· 1.40 gallons / ft2

·· 2.24 in3 / in2

SATURATED WEIGHT:·· 29.47 lbs / ft2

·· 143.88 kg / m2

ROOF PITCH:·· 0 - 5o

·· 0 - 9%

01/01/19

GREEN ROOF TO CONCRETE PAVERSSCALE: 1 1/2" = 1'-0"1

[HG 5100] PAVER PEDESTALS

[HG 5310] CONCRETE PAVERS

[HG 3320] SEMI-INTENSIVE PROTECTIVE FLEECE

HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM

Page 9: 1 ISSUED DATEDETAIL NUMBER HG 2150 - EXTENSIVE 4 SEDUM ...€¦ · [hg 5350] wood deck tiles [hg 3320] semi-intensive protective fleece hg 2150 - extensive 4" sedum tray system. issued

ISSUED DATE DETAIL NUMBER

GREEN ROOF TO WOOD DECK TILES 2150 - TP - P2

[HG 3310] PROTECTIVE FLEECE

[HG 3195] INTENSIVE GEOFOAM INSULATION

STRUCTURAL METAL DECK

CONDUCTIVE MEDIUM (as required)

COVER BOARD, ADHERED

ROOF SHEATHING

[HG 3160] PVC WATERPROOFING

[HG 6504] PRE-VEGETATED MODULE - 4"

4"

VAPOR RETARDER (as required)

[HG 3920] SLOTTED ALUMINUM EDGE (as required)

NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.

STORMWATER RETENTION:·· 1.40 gallons / ft2

·· 2.24 in3 / in2

SATURATED WEIGHT:·· 29.47 lbs / ft2

·· 143.88 kg / m2

ROOF PITCH:·· 0 - 5o

·· 0 - 9%

01/01/19

GREEN ROOF TO WOOD DECK TILESSCALE: 1 1/2" = 1'-0"1

[HG 5100] PAVER PEDESTALS

[HG 5350] WOOD DECK TILES

[HG 3320] SEMI-INTENSIVE PROTECTIVE FLEECE

HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM

Page 10: 1 ISSUED DATEDETAIL NUMBER HG 2150 - EXTENSIVE 4 SEDUM ...€¦ · [hg 5350] wood deck tiles [hg 3320] semi-intensive protective fleece hg 2150 - extensive 4" sedum tray system. issued

ISSUED DATE DETAIL NUMBER

GREEN ROOF TO PORCELAIN PAVERS 2150 - TP - P3

[HG 3310] PROTECTIVE FLEECE

[HG 3195] INTENSIVE GEOFOAM INSULATION

STRUCTURAL METAL DECK

CONDUCTIVE MEDIUM (as required)

COVER BOARD, ADHERED

ROOF SHEATHING

[HG 3160] PVC WATERPROOFING

[HG 6504] PRE-VEGETATED MODULE - 4"

4"

VAPOR RETARDER (as required)

[HG 3920] SLOTTED ALUMINUM EDGE (as required)

NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.

STORMWATER RETENTION:·· 1.40 gallons / ft2

·· 2.24 in3 / in2

SATURATED WEIGHT:·· 29.47 lbs / ft2

·· 143.88 kg / m2

ROOF PITCH:·· 0 - 5o

·· 0 - 9%

01/01/19

GREEN ROOF TO PORCELAIN PAVERSSCALE: 1 1/2" = 1'-0"1

[HG 5100] PAVER PEDESTALS

[HG 5360] PORCELAIN PAVERS

[HG 3320] SEMI-INTENSIVE PROTECTIVE FLEECE

HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM

Page 11: 1 ISSUED DATEDETAIL NUMBER HG 2150 - EXTENSIVE 4 SEDUM ...€¦ · [hg 5350] wood deck tiles [hg 3320] semi-intensive protective fleece hg 2150 - extensive 4" sedum tray system. issued

ISSUED DATE DETAIL NUMBER

[HG 6504] PRE-VEGETATED MODULE - 4"

4"

2150 - TP - T1

STORMWATER RETENTION:·· 1.40 gallons / ft2

·· 2.24 in3 / in2

ROOF PITCH:·· 0 - 5o

·· 0 - 9%

01/01/19

SCALE: 1 1/2" = 1'-0"1

GREEN ROOF TO ARTIFICIAL TURF - AGGREGATE

NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. Artificial turf must be installed and seamed with adjacent pieces running in the same direction.4. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.

GREEN ROOF TO ARTIFICIAL TURF - AGGREGATE

[HG 5410] SKYE TURF

[HG 3530] PEDESTRIAN PAVING DRAIN

[HG 5423] VERSATILE DRAINAGE MAT

[OTHERS] TREATED WOOD / COMPOSITE NAILER BOARD

- SET 1" BELOW FINISHED FLOOR ELEVATION

[OTHERS] 1" STAINLESS STEEL NAIL - SPACED EVERY 1"

WASHED SILICA SAND / [HG 5431] ENVIROFILL - GREEN(APPROX 3 LBS/SF)

[HG 3310] PROTECTIVE FLEECE

[HG 3195] INTENSIVE GEOFOAM INSULATION

STRUCTURAL METAL DECK

CONDUCTIVE MEDIUM (as required)

COVER BOARD, ADHERED

ROOF SHEATHING

[HG 3160] PVC WATERPROOFING

VAPOR RETARDER (as required)

[HG 4620] DRAINAGE AGGREGATE

SATURATED WEIGHT:·· 29.47 lbs / ft2

·· 143.88 kg / m2

[HG 3920] SLOTTED ALUMINUM EDGE (as required)

[OTHERS] HEAVY DUTY UV RESISTANT NYLON CABLE TIES

HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM

Page 12: 1 ISSUED DATEDETAIL NUMBER HG 2150 - EXTENSIVE 4 SEDUM ...€¦ · [hg 5350] wood deck tiles [hg 3320] semi-intensive protective fleece hg 2150 - extensive 4" sedum tray system. issued

ISSUED DATE DETAIL NUMBER

[HG 6504] PRE-VEGETATED MODULE - 4"

4"

2150 - TP - T2

STORMWATER RETENTION:·· 1.40 gallons / ft2

·· 2.24 in3 / in2

ROOF PITCH:·· 0 - 5o

·· 0 - 9%

01/01/19

SCALE: 1 1/2" = 1'-0"1

GREEN ROOF TO ARTIFICIAL TURF - INSULATION

NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. Artificial turf must be installed and seamed with adjacent pieces running in the same direction.4. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.

GREEN ROOF TO ARTIFICIAL TURF - INSULATION

[HG 5410] SKYE TURF

[HG 3530] PEDESTRIAN PAVING DRAIN

[HG 5423] VERSATILE DRAINAGE MAT

[OTHERS] TREATED WOOD / COMPOSITE NAILER BOARD

- SET 1" BELOW FINISHED FLOOR ELEVATION

[OTHERS] 1" STAINLESS STEEL NAIL - SPACED EVERY 1"

WASHED SILICA SAND / [HG 5431] ENVIROFILL - GREEN(APPROX 3 LBS/SF)

[HG 3193] GEOFOAM INSULATION

[HG 3310] PROTECTIVE FLEECE

[HG 3195] INTENSIVE GEOFOAM INSULATION

STRUCTURAL METAL DECK

CONDUCTIVE MEDIUM (as required)

COVER BOARD, ADHERED

ROOF SHEATHING

[HG 3160] PVC WATERPROOFING

VAPOR RETARDER (as required)

[HG 3920] SLOTTED ALUMINUM EDGE (as required)

[OTHERS] HEAVY DUTY UV RESISTANT NYLON CABLE TIES

SATURATED WEIGHT:·· 29.47 lbs / ft2

·· 143.88 kg / m2

HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM

Page 13: 1 ISSUED DATEDETAIL NUMBER HG 2150 - EXTENSIVE 4 SEDUM ...€¦ · [hg 5350] wood deck tiles [hg 3320] semi-intensive protective fleece hg 2150 - extensive 4" sedum tray system. issued

ISSUED DATE DETAIL NUMBER

DECORATIVE BALLAST STONE, 1-112" MIN. DIAMETER

1' MIN

GREEN ROOF TO ROOF PENETRATION - BALLAST STONE 2150 - TP - V1

STAINLESS STEEL HOSE CLAMP & SEALANT

[HG 3310] PROTECTIVE FLEECE

[HG 3160] PVC WATERPROOFING

[HG 3195] INTENSIVE GEOFOAM INSULATION

STRUCTURAL METAL DECK

CONDUCTIVE MEDIUM (as required)

COVER BOARD, ADHERED

SPECIFIED FLASHING MEMBRANE, HOT-AIR WELDED

ROOF SHEATHING

ROOF PENETRATION

SPECIFIED BASE FLASHING, HOT-AIR WELDED

SPECIFIED FASTENER6" O.C. AROUND PENETRATION

[HG 6504] PRE-VEGETATED MODULE - 4"

4"

VAPOR RETARDER (as required)

[HG 3920] SLOTTED ALUMINUM EDGE (as required)

NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. All flashing shall extend up roof penetration at least to the height of the top of the surfacing.4. Vapor retarder shall be sealed at roof penetration.5. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.

STORMWATER RETENTION:·· 1.40 gallons / ft2

·· 2.24 in3 / in2

SATURATED WEIGHT:·· 29.47 lbs / ft2

·· 143.88 kg / m2

ROOF PITCH:·· 0 - 5o

·· 0 - 9%

01/01/19

GREEN ROOF TO ROOF PENETRATION - BALLAST STONESCALE: 1 1/2" = 1'-0"1

HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM

Page 14: 1 ISSUED DATEDETAIL NUMBER HG 2150 - EXTENSIVE 4 SEDUM ...€¦ · [hg 5350] wood deck tiles [hg 3320] semi-intensive protective fleece hg 2150 - extensive 4" sedum tray system. issued

ISSUED DATE DETAIL NUMBER

8" MIN

GREEN ROOF TO ROOF PENETRATION 2150 - TP - V2

STAINLESS STEEL HOSE CLAMP & SEALANT

[HG 3310] PROTECTIVE FLEECE

[HG 3195] INTENSIVE GEOFOAM INSULATION

STRUCTURAL METAL DECK

CONDUCTIVE MEDIUM (as required)

COVER BOARD, ADHERED

SPECIFIED FLASHING MEMBRANE, HOT-AIR WELDED

ROOF SHEATHING

ROOF PENETRATION

SPECIFIED BASE FLASHING, HOT-AIR WELDED

SPECIFIED FASTENER 6" O.C. AROUND PENETRATION

[HG 3160] PVC WATERPROOFING

[HG 6504] PRE-VEGETATED MODULE - 4"

4"

VAPOR RETARDER (as required)

NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. All flashing shall extend up roof penetration a minimum of 8" above highest water line.4. Vapor retarder shall be sealed at roof penetration.5. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.

STORMWATER RETENTION:·· 1.40 gallons / ft2

·· 2.24 in3 / in2

SATURATED WEIGHT:·· 29.47 lbs / ft2

·· 143.88 kg / m2

ROOF PITCH:·· 0 - 5o

·· 0 - 9%

01/01/19

GREEN ROOF TO ROOF PENETRATIONSCALE: 1 1/2" = 1'-0"1

[OTHERS] HEAVY DUTY UV RESISTANT NYLON CABLE TIES

HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM

Page 15: 1 ISSUED DATEDETAIL NUMBER HG 2150 - EXTENSIVE 4 SEDUM ...€¦ · [hg 5350] wood deck tiles [hg 3320] semi-intensive protective fleece hg 2150 - extensive 4" sedum tray system. issued

ISSUED DATE DETAIL NUMBER

1' MIN

GREEN ROOF TO PARAPET WALL - BALLAST STONE 2150 - TP - W1

4"

[HG 3310] PROTECTIVE FLEECE

[HG 3195] INTENSIVE GEOFOAM INSULATION

STRUCTURAL METAL DECK

CONDUCTIVE MEDIUM (as required)

COVER BOARD, ADHERED

ROOF SHEATHING

SPECIFIED FASTENER 12" O.C.

HOT-AIR WELD

[HG 3160] PVC WATERPROOFING

[HG 6504] PRE-VEGETATED MODULE - 4"

VAPOR RETARDER (as required)

NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. All flashing shall extend a minimum of 8" above highest water line.4. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.

STORMWATER RETENTION:·· 1.40 gallons / ft2

·· 2.24 in3 / in2

SATURATED WEIGHT:·· 29.47 lbs / ft2

·· 143.88 kg / m2

ROOF PITCH:·· 0 - 5o

·· 0 - 9%

01/01/19

GREEN ROOF TO PARAPET WALL - BALLAST STONESCALE: 1 1/2" = 1'-0"1

SPECIFIED FLASHING MEMBRANE

TO ACCEPTABLE SUBSTRATE

[HG 3920] SLOTTED ALUMINUM EDGE (as required)

DECORATIVE BALLAST STONE. 1-112" MIN. DIAMETER

[OTHERS] HEAVY DUTY UV RESISTANT NYLON CABLE TIES

HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM

Page 16: 1 ISSUED DATEDETAIL NUMBER HG 2150 - EXTENSIVE 4 SEDUM ...€¦ · [hg 5350] wood deck tiles [hg 3320] semi-intensive protective fleece hg 2150 - extensive 4" sedum tray system. issued

ISSUED DATE DETAIL NUMBER

GREEN ROOF TO PARAPET WALL - CONCRETE PAVERS 2150 - TP - W2

4"

[HG 3310] PROTECTIVE FLEECE

[HG 3195] INTENSIVE GEOFOAM INSULATION

STRUCTURAL METAL DECK

CONDUCTIVE MEDIUM (as required)

COVER BOARD, ADHERED

[HG 3920] SLOTTED ALUMINUM EDGE (as required)

ROOF SHEATHING

SPECIFIED FASTENER 12" O.C.

HOT-AIR WELD

[HG 3160] PVC WATERPROOFING

[HG 6504] PRE-VEGETATED MODULE - 4"

VAPOR RETARDER (as required)

NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. All flashing shall extend a minimum of 8" above highest water line.4. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.

STORMWATER RETENTION:·· 1.40 gallons / ft2

·· 2.24 in3 / in2

SATURATED WEIGHT:·· 29.47 lbs / ft2

·· 143.88 kg / m2

ROOF PITCH:·· 0 - 5o

·· 0 - 9%

01/01/19

GREEN ROOF TO PARAPET WALL - CONCRETE PAVERS ON PEDESTALSSCALE: 1 1/2" = 1'-0"1

SPECIFIED FLASHING MEMBRANE

TO ACCEPTABLE SUBSTRATE

[HG 5100] PAVER PEDESTALS

[HG 5310] CONCRETE PAVERS

HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM

Page 17: 1 ISSUED DATEDETAIL NUMBER HG 2150 - EXTENSIVE 4 SEDUM ...€¦ · [hg 5350] wood deck tiles [hg 3320] semi-intensive protective fleece hg 2150 - extensive 4" sedum tray system. issued

ISSUED DATE DETAIL NUMBER

GREEN ROOF TO PARAPET WALL - WOOD DECK TILES 2150 - TP - W3

4"

[HG 3310] PROTECTIVE FLEECE

[HG 3195] INTENSIVE GEOFOAM INSULATION

STRUCTURAL METAL DECK

CONDUCTIVE MEDIUM (as required)

COVER BOARD, ADHERED

[HG 3920] SLOTTED ALUMINUM EDGE (as required)

ROOF SHEATHING

SPECIFIED FASTENER 12" O.C.

HOT-AIR WELD

[HG 3160] PVC WATERPROOFING

[HG 6504] PRE-VEGETATED MODULE - 4"

VAPOR RETARDER (as required)

NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. All flashing shall extend a minimum of 8" above highest water line.4. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.

STORMWATER RETENTION:·· 1.40 gallons / ft2

·· 2.24 in3 / in2

SATURATED WEIGHT:·· 29.47 lbs / ft2

·· 143.88 kg / m2

ROOF PITCH:·· 0 - 5o

·· 0 - 9%

01/01/19

GREEN ROOF TO PARAPET WALL - WOOD DECK TILES ON PEDESTALSSCALE: 1 1/2" = 1'-0"1

SPECIFIED FLASHING MEMBRANE

TO ACCEPTABLE SUBSTRATE

[HG 5100] PAVER PEDESTALS

[HG 5350] WOOD DECK TILES

HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM

Page 18: 1 ISSUED DATEDETAIL NUMBER HG 2150 - EXTENSIVE 4 SEDUM ...€¦ · [hg 5350] wood deck tiles [hg 3320] semi-intensive protective fleece hg 2150 - extensive 4" sedum tray system. issued

ISSUED DATE DETAIL NUMBER

GREEN ROOF TO PARAPET WALL - PORCELAIN PAVERS 2150 - TP - W4

4"

[HG 3310] PROTECTIVE FLEECE

[HG 3195] INTENSIVE GEOFOAM INSULATION

STRUCTURAL METAL DECK

CONDUCTIVE MEDIUM (as required)

COVER BOARD, ADHERED

[HG 3920] SLOTTED ALUMINUM EDGE (as required)

ROOF SHEATHING

SPECIFIED FASTENER 12" O.C.

HOT-AIR WELD

[HG 3160] PVC WATERPROOFING

[HG 6504] PRE-VEGETATED MODULE - 4"

VAPOR RETARDER (as required)

NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. All flashing shall extend a minimum of 8" above highest water line.4. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.

STORMWATER RETENTION:·· 1.40 gallons / ft2

·· 2.24 in3 / in2

SATURATED WEIGHT:·· 29.47 lbs / ft2

·· 143.88 kg / m2

ROOF PITCH:·· 0 - 5o

·· 0 - 9%

01/01/19

GREEN ROOF TO PARAPET WALL - PORCELAIN PAVERS ON PEDESTALSSCALE: 1 1/2" = 1'-0"1

SPECIFIED FLASHING MEMBRANE

TO ACCEPTABLE SUBSTRATE

[HG 5100] PAVER PEDESTALS

[HG 5360] PORCELAIN PAVERS

HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM

Page 19: 1 ISSUED DATEDETAIL NUMBER HG 2150 - EXTENSIVE 4 SEDUM ...€¦ · [hg 5350] wood deck tiles [hg 3320] semi-intensive protective fleece hg 2150 - extensive 4" sedum tray system. issued

ISSUED DATE DETAIL NUMBER

GREEN ROOF TO PARAPET WALL 2150 - TP - W5

4"

[HG 3310] PROTECTIVE FLEECE

[HG 3195] INTENSIVE GEOFOAM INSULATION

STRUCTURAL METAL DECK

CONDUCTIVE MEDIUM (as required)

COVER BOARD, ADHERED

ROOF SHEATHING

SPECIFIED FASTENER 12" O.C.

HOT-AIR WELD

[HG 3160] PVC WATERPROOFING

[HG 6504] PRE-VEGETATED MODULE - 4"

VAPOR RETARDER (as required)

NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. All flashing shall extend a minimum of 8" above highest water line.4. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.

STORMWATER RETENTION:·· 1.40 gallons / ft2

·· 2.24 in3 / in2

SATURATED WEIGHT:·· 29.47 lbs / ft2

·· 143.88 kg / m2

ROOF PITCH:·· 0 - 5o

·· 0 - 9%

01/01/19

GREEN ROOF TO PARAPET WALLSCALE: 1 1/2" = 1'-0"1

SPECIFIED FLASHING MEMBRANE

TO ACCEPTABLE SUBSTRATE

[OTHERS] HEAVY DUTY UV RESISTANT NYLON CABLE TIES

HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM

Page 20: 1 ISSUED DATEDETAIL NUMBER HG 2150 - EXTENSIVE 4 SEDUM ...€¦ · [hg 5350] wood deck tiles [hg 3320] semi-intensive protective fleece hg 2150 - extensive 4" sedum tray system. issued

ISSUED DATE DETAIL NUMBER

GREEN ROOF TO PARAPET WALL - CONCRETE PAVERS 2150 - TP - W6

4"

[HG 3310] PROTECTIVE FLEECE

[HG 3195] INTENSIVE GEOFOAM INSULATION

STRUCTURAL METAL DECK

CONDUCTIVE MEDIUM (as required)

COVER BOARD, ADHERED

[HG 3920] SLOTTED ALUMINUM EDGE (as required)

ROOF SHEATHING

SPECIFIED FASTENER 12" O.C.

HOT-AIR WELD

[HG 3160] PVC WATERPROOFING

[HG 6504] PRE-VEGETATED MODULE - 4"

VAPOR RETARDER (as required)

NOTES:1. Install pre-vegetated modules tight together per layout plan & water-in.2. Connect modules together with approved self-locking fasteners in any occurrence where more than one module is adjacent to another.3. All flashing shall extend a minimum of 8" above highest water line.4. Calculations performed using ASTM Standard E2397-11. Actual system weight and stormwater retention may vary.

STORMWATER RETENTION:·· 1.40 gallons / ft2

·· 2.24 in3 / in2

SATURATED WEIGHT:·· 29.47 lbs / ft2

·· 143.88 kg / m2

ROOF PITCH:·· 0 - 5o

·· 0 - 9%

01/01/19

GREEN ROOF TO PARAPET WALL - CONCRETE PAVERSSCALE: 1 1/2" = 1'-0"1

SPECIFIED FLASHING MEMBRANE

TO ACCEPTABLE SUBSTRATE

[HG 5310] CONCRETE PAVERS

[HG 3530] PEDESTRIAN PAVING DRAIN

HG 2150 - EXTENSIVE 4" SEDUM TRAY SYSTEM