17
1 Tests of Carleton and MPI TPC's with a resistive foil and a Micromegas readout at the KEK PS beam Vincent Lepeltier LAL Orsay ECFA Vienna, November 14-18th 20 Vincent Lepeltier, LAL, Orsay, France on behalf of the Canada, France, Germany, Japan, Philippines collaboration EK, TUAT Tokyo Univ., Hiroshima Univ., Kogakuin Univ., Kinki Univ., Saga Univ., Tsukuba Univ., Japan Japan SU, Philippines Philippines, Carleton Univ.of Ottawa,Univ. de Montréal, Canada Canada, MPI, Germany Germany, DAPNIA-CEA, Saclay, IN2P3-LAL and IPN, Orsay, France France ki, D. C. Arogancia, A.M. Bacala, A. Bellerive, K. Boudjemline, D. B s, M. Dixit, H. Fujishima, K. Fujii, A. Giganon, I.Giomataris, H. C. T. Higashi, Y. Kato, M. Kobayashi, K. Kodomatsu, H. Kuroiwa, V. Lep mato, J.-P. Martin, T. Matsuda, S. Matsushita, K. Nakamura, E. Neuhe h, J. Pouthas, R. L. Reserva, E. Rollin, Ph. Rosier, K. Sachs, R. Se Shin, A. Sugiyama, T. Takahashi, Y. Tanaka, T. Watanabe, A. Yamaguch T. Yamamoto, H. Yamaoka, Th. Zerguerras

1 Tests of Carleton and MPI TPC's with a resistive foil and a Micromegas readout at the KEK PS beam Vincent Lepeltier LAL Orsay ECFA Vienna, November 14-18th

Embed Size (px)

Citation preview

Page 1: 1 Tests of Carleton and MPI TPC's with a resistive foil and a Micromegas readout at the KEK PS beam Vincent Lepeltier LAL Orsay ECFA Vienna, November 14-18th

1

Tests of Carleton and MPI TPC's with a resistive foil and a Micromegas readout at the KEK PS beam

Vincent Lepeltier LAL Orsay ECFA Vienna, November 14-18th 2005

Vincent Lepeltier, LAL, Orsay, France

on behalf of the Canada, France, Germany, Japan, Philippines collaboration

KEK, TUAT Tokyo Univ., Hiroshima Univ., Kogakuin Univ., Kinki Univ., Saga Univ., Tsukuba Univ., JapanJapan

MSU, PhilippinesPhilippines, Carleton Univ.of Ottawa,Univ. de Montréal, CanadaCanada, MPI, GermanyGermany, DAPNIA-CEA, Saclay, IN2P3-LAL and IPN, Orsay, France France

T. Araki, D. C. Arogancia, A.M. Bacala, A. Bellerive, K. Boudjemline, D. Burke, P. Colas, M. Dixit, H. Fujishima, K. Fujii, A. Giganon, I.Giomataris, H. C. Gooc,

M. Habu, T. Higashi, Y. Kato, M. Kobayashi, K. Kodomatsu, H. Kuroiwa, V. Lepeltier, J.Miyamato, J.-P. Martin, T. Matsuda, S. Matsushita, K. Nakamura, E. Neuheimer,

O. Nitoh, J. Pouthas, R. L. Reserva, E. Rollin, Ph. Rosier, K. Sachs, R. Settles, Y. Shin, A. Sugiyama, T. Takahashi, Y. Tanaka, T. Watanabe, A. Yamaguchi,

T. Yamamoto, H. Yamaoka, Th. Zerguerras

Page 2: 1 Tests of Carleton and MPI TPC's with a resistive foil and a Micromegas readout at the KEK PS beam Vincent Lepeltier LAL Orsay ECFA Vienna, November 14-18th

2

why this collaboration?• 1T-magnet and 4 GeV/c hadron beam available at KEKKEK• 2 TPCs existing at CarletonCarleton (Ottawa) and MPIMPI (Munich)• read-out technologies developped previously at SaclaySaclay (Micromegas) and CarletonCarleton (resistive layer)

outline• why a resistive layer ?• how does it work ?• experimental set-up (TPCs and beam)• PRF and spatial resolution results• future and conclusion

Vincent Lepeltier LAL Orsay ECFA Vienna, November 14-18th 2005

+ many people enthusiast to cooperate ! 3 weeks of beam data taking in 2005 (June and October)

remind!

Page 3: 1 Tests of Carleton and MPI TPC's with a resistive foil and a Micromegas readout at the KEK PS beam Vincent Lepeltier LAL Orsay ECFA Vienna, November 14-18th

3

why a resistive layer ?transverse resolution from the full full simulation of the of the MPI Micromegas TPC (by Khalil Boudjemline, Carleton, Ottawa), with these characteristics:

2.3 x 6.3 mm2 pads, Ar-iC4H10 : 95-5%, B = 1T, E=200V/cm, mean gain= 10000

the spatial transverse resolution results from three contributions: the spatial transverse resolution results from three contributions:

- a constant term σ0 mainly due to electronics, noise, …

670 m

the spatial transverse resolution results from three contributions:

- a constant term σ0 mainly due to electronics, noise, …

- a term coming from the finite pad width s (s/√12≈670μm for Φ≈0, Z=0)

the spatial transverse resolution results from three contributions:

- a constant term a constant term σσ00 mainly due to electronics, noise, …

- a term coming from the finite pad widththe finite pad width s (s/√12≈670μm for Φ≈0, Z=0)

- a diffusion termdiffusion term √Z √Z (and 1/√N1/√Neff eff )

Vincent Lepeltier LAL Orsay ECFA Vienna, November 14-18th 2005

σ0

CD=193μm/√cm Neff=28CD=193μm/√cm Neff=28 (fitted)

Page 4: 1 Tests of Carleton and MPI TPC's with a resistive foil and a Micromegas readout at the KEK PS beam Vincent Lepeltier LAL Orsay ECFA Vienna, November 14-18th

4

how to extrapolateextrapolate the transverse resolutiontransverse resolution to: a 250cm long TPC250cm long TPC with a low diffusion gaslow diffusion gas mixture

for example Ar-CF4 at 4T, Cd=25 μm/√cm (200) with ωτ≈20 (2.5)σx2

Z

.5 mm2

0.25

0 1 2 m

Ar-isoC4H10 @1TCd=200 μm/√cm

resolution dominated by diffusiondiffusion

Vincent Lepeltier LAL Orsay ECFA Vienna, November 14-18th 2005

Ar-CF4 @ 4T Cd=25 μm/√cm

resolution dominated by pad widthpad width

σd ≈80μm only !

how to decrease (suppress) this contribution?

Page 5: 1 Tests of Carleton and MPI TPC's with a resistive foil and a Micromegas readout at the KEK PS beam Vincent Lepeltier LAL Orsay ECFA Vienna, November 14-18th

5

how to decrease (suppress) the pad width contribution?

1.1. decreasedecrease by a factor (>5?) the pad widthpad width 107 channels

irrealistic (loss of resolution with Φ angle) but leads to a new promising concept of digital TPCnew promising concept of digital TPC: minipads minipads (1mm2), with single electronsingle electron detection (see presentations by Jan Timmermans , Klaus Desch & Michael

Hauschild)2. diffuse electronsdiffuse electrons AFTER multiplication (proposed by VL)

«impossible» with Micromegas difficult with GEM: needs for σdiff≈ 700-800μm (for 2mm pad width), i.e. typically ~3cm defocusing at 2-3 kV/cm

3. set a resistive foilresistive foil on the pad plane proposed by Madhu Dixit (Carleton, Ottawa) ~4 years ago

Vincent Lepeltier LAL Orsay ECFA Vienna, November 14-18th 2005

Page 6: 1 Tests of Carleton and MPI TPC's with a resistive foil and a Micromegas readout at the KEK PS beam Vincent Lepeltier LAL Orsay ECFA Vienna, November 14-18th

6

50 m pillars

drift gap

meshamplification gap

Al-Si Cermet mylar 50μm

ideaidea: a uniform high resistivity 1 M/ Al-Si Cermet is glued on the pad plane

for more info: see presentation by Madhu Dixit at the ILC 2005 Snowmass workshop Vincent Lepeltier LAL Orsay ECFA Vienna, November 14-18th 2005

Page 7: 1 Tests of Carleton and MPI TPC's with a resistive foil and a Micromegas readout at the KEK PS beam Vincent Lepeltier LAL Orsay ECFA Vienna, November 14-18th

7

• Micromegas anode with a highly 50μm resistive film bonded to a readout plane with an insulating spacer.• 2-dimensional continuous RC network defined by material properties(R) & geometry (C).• point charge at r = 0 & t = 0 disperses with time.• time dependent anode charge density sampled by readout pads.

the charge evolution in r and t is the ”telegraph” equation

t

1

RC

2r2

1

r

r

(r, t) RC

2t

r2RC

4 te

(r,t) integral over pads

(r)Q

r / mmmm ns

charge dispersion with a resistive anode

Vincent Lepeltier LAL Orsay ECFA Vienna, November 14-18th 2005

drifting electron

micromegas

3 2 1

• Micromegas anode with a highly 50μm resistive film bonded to a readout plane with an insulating spacer.• 2-dimensional continuous RC network defined by material properties(R) & geometry (C).• point charge at r = 0 & t = 0 disperses with time.• time dependent anode charge density sampled by readout pads.

the charge evolution in r and t is the ”telegraph” equation, governed by the RCRC time constant parameter:

Page 8: 1 Tests of Carleton and MPI TPC's with a resistive foil and a Micromegas readout at the KEK PS beam Vincent Lepeltier LAL Orsay ECFA Vienna, November 14-18th

8

PRF[x,(z),,a,b] (1 a2x

2 a4x4 )

(1 b2x2 b4x

4 )

a2,, a4, b2 & b4 can be written downin terms of and & two scale parameters a & b.

TPC track PRFs with Micromegas

• the PRF (Pad Response Function) is not Gaussiannot Gaussian• the PRF depends on track position relative to the pad PRF = PRF(x,z)• PRF can be characterized by its FWHM (z) & base width (z).• PRFs determined from the data have been fitted to a functional form

consisting of a ratio of two symmetric 4th order polynomials.

Vincent Lepeltier LAL Orsay ECFA Vienna, November 14-18th 2005

Ar:CO2 (90:10)@0T 2x6

mm2 pads

the PRFPRF fits well with at least three pads

Page 9: 1 Tests of Carleton and MPI TPC's with a resistive foil and a Micromegas readout at the KEK PS beam Vincent Lepeltier LAL Orsay ECFA Vienna, November 14-18th

9

TPC in JACEE magnet

4 GeV/c beam

experimental set-up at KEK: the beam line

4 GeV/c Pb Sc Č Č Sc TPC1 magnet TPC2 Π

JACEE supraconducting magnet inner diameter : 850 mm effective length: 1 m

Vincent Lepeltier LAL Orsay ECFA Vienna, November 14-18th 2005

Page 10: 1 Tests of Carleton and MPI TPC's with a resistive foil and a Micromegas readout at the KEK PS beam Vincent Lepeltier LAL Orsay ECFA Vienna, November 14-18th

10

experimental set-up at KEK: the two TPC’s

Carleton Ottawa TPC - Micromegas mesh 10x10 cm2

- drift distance: 16 cm

- 126 2.3 x 6.3 mm2 pads in 7 rows

- ALEPH preamps + 25MHz Montréal FADC

- gas mixtures: Ar-5%isoC4 H10

B=1T,80kevts@220&80V/cm Ar-10%CO2 B =0T,80kevts- evt rate ~3Hz (2.5 Gb/hr).- beam π+/π-/e

MPI+Saclay-Orsay TPC

- Micromegas mesh 10x10 cm2

- drift distance 26cm - 512 2x6.3 mm2 pads in 16 rows- ALEPH preamps + 11MHz FADC - gas mixtures: Ar-5%isoC4H10

B=1T,19kevts@220V/cm “ B=1T,20kevts@80V/cm “ B=1T,11kevts@Φ=10° Ar-10%CO2 B=0T,14 kevts- evt rate ~0.3Hz- beam π+/π-/e

Vincent Lepeltier LAL Orsay ECFA Vienna, November 14-18th 2005

Page 11: 1 Tests of Carleton and MPI TPC's with a resistive foil and a Micromegas readout at the KEK PS beam Vincent Lepeltier LAL Orsay ECFA Vienna, November 14-18th

11

detector quality control plots

Vincent Lepeltier LAL Orsay ECFA Vienna, November 14-18th 2005

4GeV – beam 55Fe peak 5.9keV

55Fe peak 5.9keVescape peak

3keV

energy resolution σ= 8% for Ar-5%isobutane

MPI TPC micromesh signal (10x10cm2)

Page 12: 1 Tests of Carleton and MPI TPC's with a resistive foil and a Micromegas readout at the KEK PS beam Vincent Lepeltier LAL Orsay ECFA Vienna, November 14-18th

12

detector quality control plots

Vincent Lepeltier LAL Orsay ECFA Vienna, November 14-18th 2005

Resolution microMegas w/ Resistive FoilArIso - KEK October 16th, 2005

0

0,05

0,1

0,15

0,2

0,25

0,3

240 260 280 300 320 340 360 380

Vmesh (V)

Res

olu

tio

n

energy resolution (σ) vs mesh HV

σ=7%

55Fe source Ar+5%iso-C4H10

MPI TPC

Gain microMegas w/ Resistive FoilArIso - KEK October 16th, 2005

y = 0,029e0,0366x

R2 = 0,9989

100

1000

10000

100000

1000000

10000000

200 250 300 350 400 450

Vmesh (V)

Ga

in

gain vs mesh HV

Page 13: 1 Tests of Carleton and MPI TPC's with a resistive foil and a Micromegas readout at the KEK PS beam Vincent Lepeltier LAL Orsay ECFA Vienna, November 14-18th

13

data quality control: event display

Vincent Lepeltier LAL Orsay ECFA Vienna, November 14-18th 2005

MPI TPC event display

amplitude vs time distributions

Carleton Ottawa TPC

spreading of charge due to foil can be seen across six pads

Page 14: 1 Tests of Carleton and MPI TPC's with a resistive foil and a Micromegas readout at the KEK PS beam Vincent Lepeltier LAL Orsay ECFA Vienna, November 14-18th

14

data quality control: event display

Vincent Lepeltier LAL Orsay ECFA Vienna, November 14-18th 2005

MPI TPCfunny event!

low momentum particle (r=3.5cm at 1T)

Page 15: 1 Tests of Carleton and MPI TPC's with a resistive foil and a Micromegas readout at the KEK PS beam Vincent Lepeltier LAL Orsay ECFA Vienna, November 14-18th

15

results: PRF vs Z

Vincent Lepeltier LAL Orsay ECFA Vienna, November 14-18th 2005

Z =1 cm Z =2 cm Z = 3cm

Z = 4cm Z =5 cm Z = 6cm

Z =7 cm Z = 8cm Z =9 cm

Ar/iC4H10:95/05@1T

FWHM≈2mm

width2 (mm2)

Carleton Ottawa TPC

FWHM≈2.6mm

Page 16: 1 Tests of Carleton and MPI TPC's with a resistive foil and a Micromegas readout at the KEK PS beam Vincent Lepeltier LAL Orsay ECFA Vienna, November 14-18th

16

results: resolution vs Z

Vincent Lepeltier LAL Orsay ECFA Vienna, November 14-18th 2005

Ar/iC4H10:95/05@1T

Carleton Ottawa TPCπ+ beam E=80V/cm

σ0 = 83 ± 22 µm

CD/√Neff = 57 ± 3 µm/√cm

MPI TPC π+ beam E=220V/cm

preliminary

σ(mm)

VERYVERY preliminary!!analysis program not

optimised for PRF

Page 17: 1 Tests of Carleton and MPI TPC's with a resistive foil and a Micromegas readout at the KEK PS beam Vincent Lepeltier LAL Orsay ECFA Vienna, November 14-18th

17

conclusion and future

• it has been proven that a transverse resolution of transverse resolution of ~50~50μμmm has been achieved.

• a resistive foila resistive foil allows to suppress the limitation on the resolution due to the pad width

• with a resistive foil, and a low diffusion gas (Cd~25μm/√cm@4T), the PRF will be ~ independant of the drift distance

(for example, for the choice made for this experiment, the PRF shoud increase from 2mm at Z=0 to 2.2mm at Z=2.5m)

the compromise should be (easily) done between the gas mixture, the pad width and the foil resistivity -> more flexibility for the construction

• more work to be done on the data analysisdata analysis and also many data to be analysed.• new tests in the future?new tests in the future? - no more beam at KEK - DESY or CERN? with JACEE? - new cosmic data? with te Saclay-Orsay-Berkeley TPC?

Vincent Lepeltier LAL Orsay ECFA Vienna, November 14-18th 2005

many thanks to the KEK support(management and technical teams)