26
Wireless Curriculum Development Section Wireless Curriculum Development Section ISSUE ISSUE WG001209 WG001209 MSOFTX3000 to MSOFTX3000 to PSTN Data Configuration PSTN Data Configuration 1.0 1.0

10 Wg001209 Msoftx3000 to Pstn Data Configuration Issue 1.0

Embed Size (px)

Citation preview

Page 1: 10 Wg001209 Msoftx3000 to Pstn Data Configuration Issue 1.0

Wireless Curriculum Development SectionWireless Curriculum Development SectionWireless Curriculum Development SectionWireless Curriculum Development Section

ISSUEISSUE

WG001209WG001209 MSOFTX3000 to MSOFTX3000 to PSTN Data ConfigurationPSTN Data Configuration

WG001209WG001209 MSOFTX3000 to MSOFTX3000 to PSTN Data ConfigurationPSTN Data Configuration

1.01.0

Page 2: 10 Wg001209 Msoftx3000 to Pstn Data Configuration Issue 1.0

2 Confidential Information of Huawei. No Spreading without Permission.

Security Level: Internal

ObjectivesObjectives

Upon completion of this course, the trainees should be able to :Upon completion of this course, the trainees should be able to :

Understand trunk route selection

process

Understand trunk table relation

Understand trunk route selection

process

Understand trunk table relation

Page 3: 10 Wg001209 Msoftx3000 to Pstn Data Configuration Issue 1.0

3 Confidential Information of Huawei. No Spreading without Permission.

Security Level: Internal

ReferencesReferences

《MSOFTX3000 Operation Manual-Data Configuration》

Page 4: 10 Wg001209 Msoftx3000 to Pstn Data Configuration Issue 1.0

4 Confidential Information of Huawei. No Spreading without Permission.

Security Level: Internal

Course ContentsCourse Contents

Chap 1 Basic Concept

Chap 2 Interworking with PSTN

Page 5: 10 Wg001209 Msoftx3000 to Pstn Data Configuration Issue 1.0

5 Confidential Information of Huawei. No Spreading without Permission.

Security Level: Internal

Basic ConceptsBasic Concepts

General Trunk Selection Process of a Call

Route Route analysisanalysis

RouteRoute Subroute Subroute selectionselection

Trunk group Trunk group selectionselection

Circuit Circuit selectionselection

Office DirectionOffice Direction

Page 6: 10 Wg001209 Msoftx3000 to Pstn Data Configuration Issue 1.0

6 Confidential Information of Huawei. No Spreading without Permission.

Security Level: Internal

Basic ConceptsBasic Concepts

Route

AA BB

CC

DD

Sub-route 1

Sub-route 2

Sub-route 3

Route is a logic definition which indicates a selection scheme of a path from the local office to the called party. One route may include several sub-routes.

Page 7: 10 Wg001209 Msoftx3000 to Pstn Data Configuration Issue 1.0

7 Confidential Information of Huawei. No Spreading without Permission.

Security Level: Internal

Basic ConceptsBasic Concepts

Route Selection Source CodeRoute Selection Code

Route Selection Code: is mainly defined by the called number.

locallocalMSCMSC

MSC-BMSC-BPSTNPSTN

Route selection

code 0Route

selection code 1

Page 8: 10 Wg001209 Msoftx3000 to Pstn Data Configuration Issue 1.0

8 Confidential Information of Huawei. No Spreading without Permission.

Security Level: Internal

Basic ConceptsBasic Concepts

Route Selection Source CodeRoute Selection Code

Route selection source code and route selection code define the route number.Route selection source code:is mainly defined by the caller.

MSCMSC

GMSC-BGMSC-BGMSC-AGMSC-A

MS-A MS-B

Route selection source code: 0Route selection

code:0

Route selection source code: 1Route selection

code: 0

PSTN -CPSTN -C

call source 0 call source 1

Page 9: 10 Wg001209 Msoftx3000 to Pstn Data Configuration Issue 1.0

9 Confidential Information of Huawei. No Spreading without Permission.

Security Level: Internal

Basic ConceptsBasic Concepts

Office Direction and Sub-route

Office Direction: when one office is connected with the local office directly through trunk line instead of through the tandem office, the route to this office is called an office direction of the local office.Sub-route: Sub-route is an element of the route, indicating the physical channel to another switching equipment. It is composed of several trunk groups which may cross different modules.

Page 10: 10 Wg001209 Msoftx3000 to Pstn Data Configuration Issue 1.0

10 Confidential Information of Huawei. No Spreading without Permission.

Security Level: Internal

Basic ConceptsBasic Concepts

Diagram of route composition

AA BB

CC

DD

Sub-route 1

Sub-route 2

Sub-route 3

In this Figure, A, B, C and D stand for 4 sets of exchange office. It can be found from the figure that A has 3 office directions - B, C and D, and each of them has one sub-route separately - sub-route 1, 2 and 3. The route from A to B includes these 3 sub-routes, in which sub-route 1 is the direct sub-route including 5 trunk groups, and sub-routes 2 and 3 are indirect sub-routes including 4 and 3 trunk groups respectively.

Page 11: 10 Wg001209 Msoftx3000 to Pstn Data Configuration Issue 1.0

11 Confidential Information of Huawei. No Spreading without Permission.

Security Level: Internal

Basic ConceptsBasic Concepts

Trunk Group

Trunk group is one of the component elements of a sub-

route.

Trunk group is a group of trunk circuits with the same

quality

Page 12: 10 Wg001209 Msoftx3000 to Pstn Data Configuration Issue 1.0

12 Confidential Information of Huawei. No Spreading without Permission.

Security Level: Internal

Basic ConceptsBasic Concepts

Trunk Circuit

Trunk circuit is the component element of a trunk

group.

One trunk circuit occupies one time slot of PCM.

Trunk circuits can be used for voice, synchronization.

Page 13: 10 Wg001209 Msoftx3000 to Pstn Data Configuration Issue 1.0

13 Confidential Information of Huawei. No Spreading without Permission.

Security Level: Internal

Basic ConceptsBasic Concepts

CIC (Circuit Identification Code)

CIC is a kind of coding for circuits in CCS7 signaling. CIC of the local office and the remote office connected with the local office should be encoded in a unified way.

CIC=0

CIC=1

CIC=31

Office-A Office-B

Page 14: 10 Wg001209 Msoftx3000 to Pstn Data Configuration Issue 1.0

14 Confidential Information of Huawei. No Spreading without Permission.

Security Level: Internal

Basic ConceptsBasic Concepts

Relation between Basic Concepts of Trunk

A route can correspond to at most 5 sub-routes, and the selection mode has different ways. The sub-route is composed of trunk groups Trunk groups may be of different circuit types and can exist crossing multi modules, and there are multiple ways for the sub-route to select trunk group. Trunk circuits of the same attributes form a trunk group, and there are multiple ways for the trunk group to select trunk circuits.

Page 15: 10 Wg001209 Msoftx3000 to Pstn Data Configuration Issue 1.0

15 Confidential Information of Huawei. No Spreading without Permission.

Security Level: Internal

Basic ConceptsBasic Concepts

Sub-route Selection Modes

A route can correspond to at most 5 sub-routes, and the selection mode may be sequential selection or percentage selection.

Route No. Route Type Subroute selection mode

1st --5th subroute

Percentage 1--5

Page 16: 10 Wg001209 Msoftx3000 to Pstn Data Configuration Issue 1.0

16 Confidential Information of Huawei. No Spreading without Permission.

Security Level: Internal

Basic ConceptsBasic Concepts

Trunk Group Selection Modes

The sub-route is composed of trunk groups, and there are multiple ways for the sub-route to select trunk group.

Subroute TableSubroute Table

Maximum

Random

Subroute No. Subroute Name Office direction

Trunk group selection mode

cycle

Minimum

Page 17: 10 Wg001209 Msoftx3000 to Pstn Data Configuration Issue 1.0

17 Confidential Information of Huawei. No Spreading without Permission.

Security Level: Internal

Basic ConceptsBasic Concepts

Trunk Circuits Selection Modes

•Trunk circuits of the same attributes form a trunk group.•There are multiple ways for the trunk group to select trunk circuits.

Trunk group number

Call source code

Circuit type

Goup direction Circuit selection mode

Maximum

Minimum

FIFO

Random

cycle

Main/ non- main control

Page 18: 10 Wg001209 Msoftx3000 to Pstn Data Configuration Issue 1.0

18 Confidential Information of Huawei. No Spreading without Permission.

Security Level: Internal

Course ContentsCourse Contents

Chap 1 Basic Concept

Chap 2 Interworking with PSTN

Page 19: 10 Wg001209 Msoftx3000 to Pstn Data Configuration Issue 1.0

19 Confidential Information of Huawei. No Spreading without Permission.

Security Level: Internal

Route Selection SchemeRoute Selection Scheme

1. M S --M S1. M S --M S

2. M S --P S T N2. M S --P S T N

M S O FTX 3000M S O FTX 3000 P S T NP S T N1.IAM

5.2 p ag in g

M S O FTX 3000M S O FTX 3000

H L RH L R

4 .S R I rep o n se1.S en d R o utin g In fo .(S R I)

B S CB S C

o th ero th er M S O FTX 3000M S O FTX 3000

5 .1 . IAM (M S R N , ad dd resing cu rren t V M S C )

C all F lo w

2. P ro vid e R o am in g N u m ber(P R N )

3. P R N rep o n se

Page 20: 10 Wg001209 Msoftx3000 to Pstn Data Configuration Issue 1.0

20 Confidential Information of Huawei. No Spreading without Permission.

Security Level: Internal

Route Selection SchemeRoute Selection Scheme

A interface Route A interface Route SelectionSelection

local call

(PSTN or other PLMN office)

HLRHLR

(Requesting MSRN from HLR)

Route Selection Scheme

Called Number Called Number AnalysisAnalysis

Trunk SS7 Route Trunk SS7 Route SelectionSelection

Page 21: 10 Wg001209 Msoftx3000 to Pstn Data Configuration Issue 1.0

21 Confidential Information of Huawei. No Spreading without Permission.

Security Level: Internal

Data configuration procedures for interworking with PSTN

Data configuration procedures for interworking with PSTN

Procedure Command

Configure routing information1) Add office direction to PSTN2) Add Sub-route3) Add route4) Add route analysis

(ADD CNACLD)ADD OFCADD SRT ADD RTADD RTANA

Configure trunk circuit1) Add SS7 trunk group2) Add SS7 trunk circuit

ADD N7TGADD N7TKC

Page 22: 10 Wg001209 Msoftx3000 to Pstn Data Configuration Issue 1.0

22 Confidential Information of Huawei. No Spreading without Permission.

Security Level: Internal

Data configuration procedures for interworking with PSTN

Data configuration procedures for interworking with PSTN

Procedure Command

Negotiate and prepare data1) Configure interworking data between MSOFTX3000 and MGW2) Add semi-permanent connection at MGW

ADD MGW(LST FECFG)ADD SCTPMGW(MOD SCTPPARA)ADD MGWCPBSET DPAADD TDMIUADD SPC

Configure MTP1) Add MTP DSP2) Add MTP link set3) Add MTP route4) Add MTP link

ADD N7DSPADD N7LKSADD N7RTADD N7LNK

Page 23: 10 Wg001209 Msoftx3000 to Pstn Data Configuration Issue 1.0

23 Confidential Information of Huawei. No Spreading without Permission.

Security Level: Internal

Parameter relationship (MTP) between MSOFTX3000 and PSTN

Parameter relationship (MTP) between MSOFTX3000 and PSTN

ADD N7DSP

[DSP index][Original Point Code]

[DPC]

[IN]

ADD N7LKS

[LinkSet Index]

ADD N7RT

[Priority]

ADD N7LNK

[Link No]

[Start Circuit No

[LinkSet Index]

PSTN

Local OPC

[Adjacent Point Index]

[LinkSet Index

[DSP index]

SLC

ADD N7DSP ADD N7LKS

ADD N7RT

[Priority]

ADD N7LNK

[Link No]

[Start Circuit No

[Signaling Link Code]

MSOFTX3000 parametersPSTN parameters

Peer end MSC DPC

Signaling network indicator

OPC

[Adjacent Point Index]

[DSP index]

ADD N7DSP ADD N7LKS

]

ADD N7RT

[Priority]

ADD N7LNK

[Link No]

[Start Circuit No

PSTN

Local OPC

[DSP index]

SLC

ADD N7DSP ADD N7LKS

ADD N7RT

[Priority]

ADD N7LNK

[Link No.]

[Start Circuit No.]

Peer end MSC DPC

Signaling network indicator

OPC

[DSP index]

Page 24: 10 Wg001209 Msoftx3000 to Pstn Data Configuration Issue 1.0

24 Confidential Information of Huawei. No Spreading without Permission.

Security Level: Internal

Parameter relationship (Trunk circuit) between MSOFTX3000 and PSTN

Parameter relationship (Trunk circuit) between MSOFTX3000 and PSTN

MSOFTX3000 parametersPeer office parameters

ADD OFC

[Destination Point Code]

ADD SRT

[Sub-route Number]

[Office Direction Number]

[signal bearer type]

[Office directioin]

ADD RT

[Route Number]

[Network ID]

[1st sub-route]

ADD RTANA

[Route Selection Code] (LST CNACLD)

[Route Number]

Destination entity signaling point code

Start CIC

[Route Selection Source Code](LST CALLSRC)

ADD N7TG

ADD N7TKC

[Start CIC]

[Trunk Group]

[Start circuit termination ID]

[Sub-route number]

[Trunk Group]

[MGW Index] (ADD MGW)

[OPC](SET OFI)

[DPC]

[Call source] (ADD CALLSRC)

Page 25: 10 Wg001209 Msoftx3000 to Pstn Data Configuration Issue 1.0

25 Confidential Information of Huawei. No Spreading without Permission.

Security Level: Internal

SummarySummary

Master data configuration steps

Master data configuration method

Page 26: 10 Wg001209 Msoftx3000 to Pstn Data Configuration Issue 1.0

26 Confidential Information of Huawei. No Spreading without Permission.

Security Level: Internal