12-22 Molded Case Circuit Breakers 10-225 Amperes F-Frame Cutler-Hammer January 2001 Vol. 1,Ref. No. [0488] Table 12-35. Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Max. Cont. Ampere Rating @40°C 10® 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 150 175 200 225 600V AC Maximum, 250V DC 14 kAIC <g> 600V AC Type FOB (Includes Terminals on Load End Only) 2-Pole Catalog Number FDB2010 FDB2015 FOB2020 FDB2025 FDB2030 FDB2035 FDB2040 FDB2045 FDB2050 FDB2060 FDB2070 FDB2080 FDB2090 FDB2100 FDB2110 FDB2125 FDB2150 Price U.S. $ 435. 435. 435. 435. 435. 435. 435. 393. 435. 435. 565. 565. 565. 565. 1,260. 1,260. 1,260. 3-Pole Catalog Number FDB3010 FDB3015 FDB3020 FDB3025 FDB3030 FDB3035 FDB3040 FDB3045 FDB3050 FDB3060 FDB3070 FDB3080 FDB3090 FDB3100 FDB3110 FDB3125 FDB3150 Price U.S. $ 570. 570. 570. 570. 570. 570. 570. 570. 570. 570. 695. 695. 695. 695. 1,565. 1,565. 1,565. 4-Pole Catalog Number FDB4010 FDB4015 FDB4020 FOB4025 FDB4030 FDB4035 FDB4040 FDB4045 FDB4050 FDB4060 FDB4070 FDB4080 FDB4090 FDB4100 FDB4110 FDB4125 FDB4150 Price U.S. S 910. 910. 910. 910. 910. 910. 910. 910. 910. 1,110. 1,110. 1,110. 1,110. 1,110. 2,495. 2,495. 2,495. 277V ACMaximum, 125V DC 25 kAIC @ 277V AC 600V AC Maximum, 250V DC 25 kAIC @ 480V AC Type FD (Includes Terminals on Load End Only) 1-Pole Catalog Number FD1010 FD1015S FD1020* FD1025 FD1030 FD1035 FD1040 FD1045 FD1050 FD1060 FD1070 FD1080 FD1090 FD1100 FD1110 FD1125 FD1150 Price U.S. S 299. 299. 299. 299. 299. 299. 299. 299. 299. 299. 335. 335. 335. 335. 760. 760. 760. 2-Pole Catalog Number FD2015 F02020 FD2025 FD2030 FD2035 FD2040 FD2045 FD2050 FD2060 FD2070 FD2080 FD2090 FD2100 FD2110 FD2125 FD2150 FD2175 FD2200 FD2225 Price U.S. S 735. 735. 735. 735. 735. 735. 735. 735. 735. 855. 855. 855. 855. 1,915. 1,915. 1,915. 1,920. 1,920. 1,920. 3-Pole Catalog Number FD3015 FD3020 FD3025 FD3030 FD3035 FD3040 FD3045 FD3050 FD3060 FD3070 FD3080 FD3090 FD3100 FD3110 FD3125 FD3150 FD3175 FD3200 FD3225 Price U.S.S 865. 865. 865. 865. 865. 865. 865. 865. 865. 975. 975. 975. 975. 2,205. 2,205. 2,205. 2,205. 2,205. 2,205. 4-Pole Catalog Number FD4015 FD4020 FD4025 FD4030 FD4035 FD4040 FD4045 FD4050 FD4060 FD4070 FD4080 FD4090 FD4100 FD4110 FD4125 FD4150 FD4175 FD4200 FD4225 Price U.S.S 1,360. 1,360. 1,360. 1,360. 1,360. 1,360. 1,360. 1,360. 1,360. 1,495. 1,495. 1,495. 1,495. 3,080. 3,080. 3,080. 3,080. 3,080. 3,080. CO Not UL listed. 5 kAIC interrupting rating. <& UL listed for SWD applications, see NEC Article 240-83 (d). Note: Instruction Leaflet/FRED Number 29C101 Table 12-36. Types HFD and FDC Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Max. Cont. Ampere Rating @40°C 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 150 175 200 225 277V AC Maximum, 125V DC 65 kAIC @ 277V AC 600V AC Maximum, 250V DC 65 kAIC @ 480V AC Type HFD (Includes Terminals on Load End Only) 1-Pole Catalog Number HFD1015 A 1 HFD1020® HFD1025 HFD1030 HFD1035 HFD1040 HFD1045 HFD1050 HFD1060 HFD1070 HFD1080 HFD1090 HFD1100 HFD1110 HFD1125 HFD1150 Price U.S.S 366. 366. 366. 366. 366. 366. 366. 366. 366. 427. 427. 428. 427. 1,001. 1,001. 1,005. 2-Pole Catalog Number HFD2015 HFD2020 HFD2025 HFD2030 HFD2035 HFD2040 HFD2045 HFD2050 HFD2060 HFD2070 HFD2080 HFD2090 HFD2100 HFD2110 HFD2125 HFD2150 HFD2175 HFD2200 HFD2225 Price U.S.S 885. 885. 885. 885. 885. 885. 885. 885. 885. 1,130. 1,130. 1,130. 1,130. 2,510. 2,510. 2,510. 2,720. 2,720. 2,720. 3-Pole Catalog Number HFD3015 HFD3020 HFD3025 HFD3030 HFD3035 HFD3040 HFD3045 HFD3050 HFD3060 HFD3070 HFD3080 HFD3090 HFD3100 HFD3110 HFD3125 HFD3150 HFD3175 HFD3200 HFD3225 Price U.S/S 1,140. 1,140. 1,140. 1,140. 1,140. 1,140. 1,140. 1,140. 1,140. 1,140. 1,140. 1,140. 1,140. 3,120. 3,120. 3,120. 3,120. 3,120. 3,120. 4-Pole Catalog Number HFD4015 HFD4020 HFD4025 HFD4030 HFD4035 HFD4040 HFD4045 HFD4050 HFD4060 HFD4070 HFD4080 HFD4090 HFD4100 HFD4110 HFD4125 HFD4150 HFD4175 HFD4200 HFD4225 Price U.S. S 1,940. 1,940. 1,940. 1,940. 1,940. 1,940. 1,940. 1,940. 1,940. 2,445. 2,445. 2,445. 2,445. 4,405. 4,405. 4,405. 4,370. 4,370. 4,370. 600V AC Maximum, 250V DC 100 kAIC @ 480V AC Type FDC Current Limiting (Includes Terminals on Load End Only) 2-Pole Catalog Number FDC2015 FDC2020 FDC2025 FDC2030 FDC2035 FDC2040 FDC2045 FDC2050 FDC2060 FDC2070 FDC2080 FDC2090 FDC2100 FDC2110 FDC2125 FDC2150 FDC2175 FDC2200 FDC2225 Price U.S.S 1,325. 1,325. 1,325. 1,325. 1,325. 1,325. 1,325. 1,325. 1,325. 1,690. 1,690. 1,690. 1,690. 3,780. 3,780. 3,780. 3,780. 3,780. 3,780. 3-Pole Catalog Number FDC3015 FDC3020 FDC3025 FDC3030 FDC3035 FDC3040 FDC3045 FDC3050 FDC3060 FDC3070 FDC3080 FDC3090 FDC3100 FDC3110 FDC3125 FDC3150 FDC3175 FDC3200 FDC3225 Price U.S.S 1,710. 1,710. 1,710. 1,710. 1,710. 1,710. 1,710. 1,710. 1,710. 2,095. 2,095. 2,095. 2,095. 4,685. 4,685. 4,685. 4,685. 4,685. 4,685. 4-Pole Catalog Number FDC4015 FDC4020 FDC4025 FDC4030 FDC4035 FDC4040 FDC4045 FDC4050 FDC4060 FDC4070 FDC4080 FDC4090 FDC4100 FDC4110 FDC4125 FDC4150 FDC4175 FDC4200 FDC4225 Price U.S.S 2,910. 2,910. 2,910. 2,910. 2,910. 2,910. 2,910. 2,910. 2,910. 3,600. 3,600. 3,600. 3,600. 6,610. 6,610. 6,610. 6,610. 6,610. 6,610. ® UL listed for SWD applications, see NEC Article 240-83(d). Note: Instruction Leaflet/FRED Number 29C101 Discount Symbol. CB-2 E:T*M For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.200.01.T.E

12-22 Molded Case Circuit Breakers Cutler-Hammer · 2015. 7. 16. · 12-22 Molded Case Circuit Breakers 10-225 Amperes F-Frame Cutler-Hammer January 2001 Vol. 1,Ref. No. [0488] Table

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 12-22 Molded Case Circuit Breakers Cutler-Hammer · 2015. 7. 16. · 12-22 Molded Case Circuit Breakers 10-225 Amperes F-Frame Cutler-Hammer January 2001 Vol. 1,Ref. No. [0488] Table

12-22 Molded Case Circuit Breakers10-225 AmperesF-Frame

Cutler-HammerJanuary 2001

Vol. 1,Ref. No. [0488]

Table 12-35. Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip UnitsMax.Cont.AmpereRating@40°C

1 0 ®152025303540455060708090

1001 1 0125150175200225

600V AC Maximum, 250V DC

14 kAIC <g> 600V ACType FOB (Includes Terminals on Load End Only)2-PoleCatalogNumber

FDB2010FDB2015FOB2020FDB2025FDB2030FDB2035FDB2040FDB2045FDB2050FDB2060FDB2070FDB2080FDB2090FDB2100FDB2110FDB2125FDB2150———

PriceU.S. $

435.435.435.435.435.435.435.393.435.435.565.565.565.565.

1,260.1,260.1,260.

———

3-PoleCatalogNumber

FDB3010FDB3015FDB3020FDB3025FDB3030FDB3035FDB3040FDB3045FDB3050FDB3060FDB3070FDB3080FDB3090FDB3100FDB3110FDB3125FDB3150———

PriceU.S. $

570.570.570.570.570.570.570.570.570.570.695.695.695.695.

1,565.1,565.1,565.

———

4-PoleCatalogNumber

FDB4010FDB4015FDB4020FOB4025FDB4030FDB4035FDB4040FDB4045FDB4050FDB4060FDB4070FDB4080FDB4090FDB4100FDB4110FDB4125FDB4150———

PriceU.S. S

910.910.910.910.910.910.910.910.910.

1 , 1 1 0 .1 , 1 1 0 .1 , 1 1 0 .1 , 1 1 0 .1 , 1 1 0 .2,495.2,495.2,495.

———

277V AC Maximum,125V DC25 kAIC @ 277V AC

600V AC Maximum, 250V DC

25 kAIC @ 480V ACType FD (Includes Terminals on Load End Only)1-PoleCatalogNumber

FD1010FD1015SFD1020*FD1025FD1030FD1035FD1040FD1045FD1050FD1060FD1070FD1080FD1090FD1100FD1110FD1125FD1150———

PriceU.S. S

299.299.299.299.299.299.299.299.299.299.335.335.335.335.760.760.760.

———

2-PoleCatalogNumber

—FD2015F02020FD2025FD2030FD2035FD2040FD2045FD2050FD2060FD2070FD2080FD2090FD2100FD2110FD2125FD2150FD2175FD2200FD2225

PriceU.S. S

735.735.735.735.735.735.735.735.735.855.855.855.855.

1,915.1 ,915 .1 ,915.1,920.1,920.1,920.

3-PoleCatalogNumber

—FD3015FD3020FD3025FD3030FD3035FD3040FD3045FD3050FD3060FD3070FD3080FD3090FD3100FD3110FD3125FD3150FD3175FD3200FD3225

PriceU.S.S

865.865.865.865.865.865.865.865.865.975.975.975.975.

2,205.2,205.2,205.2,205.2,205.2,205.

4-PoleCatalogNumber

—FD4015FD4020FD4025FD4030FD4035FD4040FD4045FD4050FD4060FD4070FD4080FD4090FD4100FD4110FD4125FD4150FD4175FD4200FD4225

PriceU.S.S

1,360.1,360.1,360.1,360.1,360.1,360.1,360.1,360.1,360.1,495.1,495.1,495.1,495.3,080.3,080.3,080.3,080.3,080.3,080.

CO Not UL listed. 5 kAIC interrupting rating.<& UL listed for SWD applications, see NEC Article 240-83 (d).Note: Instruction Leaflet/FRED Number 29C101

Table 12-36. Types HFD and FDC Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip UnitsMax.Cont.AmpereRating@40°C

15 •2025303540455060708090

1001 1 0125150175200225

277V AC Maximum,125V DC65 kAIC @ 277V AC

600V AC Maximum, 250V DC

65 kAIC @ 480V ACType HFD(Includes Terminals on Load End Only)1-PoleCatalogNumber

HFD1015 A1

HFD1020®HFD1025HFD1030HFD1035HFD1040HFD1045HFD1050HFD1060HFD1070HFD1080HFD1090HFD1100HFD1110HFD1125HFD1150———

PriceU.S.S

366.366.366.366.366.366.366.366.366.427.427.428.427.

1,001.1,001.1,005.

———

2-PoleCatalogNumber

HFD2015HFD2020HFD2025HFD2030HFD2035HFD2040HFD2045HFD2050HFD2060HFD2070HFD2080HFD2090HFD2100HFD2110HFD2125HFD2150HFD2175HFD2200HFD2225

PriceU.S.S

885.885.885.885.885.885.885.885.885.

1,130 .1,130.1,130.1 ,130 .2,510.2,510.2,510.2,720.2,720.2,720.

3-PoleCatalogNumber

HFD3015HFD3020HFD3025HFD3030HFD3035HFD3040HFD3045HFD3050HFD3060HFD3070HFD3080HFD3090HFD3100HFD3110HFD3125HFD3150HFD3175HFD3200HFD3225

PriceU.S/S

1,140 .1,140.1,140.1,140.1 ,140 .1 ,140 .1 ,140 .1,140.1 ,140 .1,140.1,140.1,140.1 ,140.3,120.3,120.3,120.3,120.3,120.3,120.

4-PoleCatalogNumber

HFD4015HFD4020HFD4025HFD4030HFD4035HFD4040HFD4045HFD4050HFD4060HFD4070HFD4080HFD4090HFD4100HFD4110HFD4125HFD4150HFD4175HFD4200HFD4225

PriceU.S. S

1,940.1,940.1,940.1,940.1,940.1,940.1,940.1,940.1,940.2,445.2,445.2,445.2,445.4,405.4,405.4,405.4,370.4,370.4,370.

600V AC Maximum, 250V DC

100 kAIC @ 480V ACType FDC Current Limiting(Includes Terminals on Load End Only)2-PoleCatalogNumber

FDC2015FDC2020FDC2025FDC2030FDC2035FDC2040FDC2045FDC2050FDC2060FDC2070FDC2080FDC2090FDC2100FDC2110FDC2125FDC2150FDC2175FDC2200FDC2225

PriceU.S.S

1,325.1,325.1,325.1,325.1,325.1,325.1,325.1,325.1,325.1,690.1,690.1,690.1,690.3,780.3,780.3,780.3,780.3,780.3,780.

3-PoleCatalogNumber

FDC3015FDC3020FDC3025FDC3030FDC3035FDC3040FDC3045FDC3050FDC3060FDC3070FDC3080FDC3090FDC3100FDC3110FDC3125FDC3150FDC3175FDC3200FDC3225

PriceU.S.S

1,710.1 ,710 .1 ,710 .1,710.1 ,710 .1 ,710 .1 ,710 .1 , 7 1 0 .1 , 7 1 0 .2,095.2,095.2,095.2,095.4,685.4,685.4,685.4,685.4,685.4,685.

4-PoleCatalogNumber

FDC4015FDC4020FDC4025FDC4030FDC4035FDC4040FDC4045FDC4050FDC4060FDC4070FDC4080FDC4090FDC4100FDC4110FDC4125FDC4150FDC4175FDC4200FDC4225

PriceU.S.S

2,910.2,910.2,910.2,910.2,910.2,910.2,910.2,910.2,910.3,600.3,600.3,600.3,600.6,610.6,610.6,610.6,610.6,610.6,610.

® UL listed for SWD applications, see NEC Article 240-83(d).Note: Instruction Leaflet/FRED Number 29C101

Discount Symbol. CB-2

E:T*M For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.200.01.T.E

Page 2: 12-22 Molded Case Circuit Breakers Cutler-Hammer · 2015. 7. 16. · 12-22 Molded Case Circuit Breakers 10-225 Amperes F-Frame Cutler-Hammer January 2001 Vol. 1,Ref. No. [0488] Table

12-2

For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.200.01.T.E

January 2001

12

Product Line OverviewVol. 1, Ref. No. [0468]

Product Line DescriptionCutler-Hammer Molded Case Circuit Breakers are designed to provide circuit protection for low voltage distribution systems. They are described by NEMA as, “. . . a device for closing and inter-rupting a circuit between separable contacts under both normal and abnormal conditions,” and furthermore as, “. . . a breaker assembled as an integral unit in a supporting and enclosing housing of insulating material.” The NEC describes them as, “A device designed to open and close a circuit by non-automatic means, and to open the circuit automatically on a predetermined overload of current, without injury to itself when properly applied within its rating.”

So designed, Cutler-Hammer circuit breakers protect conductors against overloads and conductors and con-nected apparatus, such as motors and motor starters, against short circuits.

In low voltage distribution systems, there are many varied applications of molded case circuit breakers. Cutler-Hammer offers the most comprehensive family of molded case circuit breakers in the industry.

This family of circuit breakers includes:

■ Thermal Magnetic Trip Breakers■ Electronic rms Trip Breakers■ Molded Case Switches■ Motor Circuit Protectors■ Current Limiting Breakers■ Special Application Breakers■ World Breakers

Special CalibrationSpecial non-UL-listed calibrations are available for certain ambient temperatures other than 40°C and for frequencies other than 50/60 Hz or DC. Reduced interrupting ratings will apply for 400 Hz applications. Maximum thermal calibration is limited to 135A at 400 Hz.

50°C CalibrationAdd suffix V to Catalog Number for complete breaker, listed above, when ordering listed ampere ratings for breakers to be used in 50°C ambients.

Moisture-Fungus TreatmentAll circuit breaker cases are molded from glass-polyester which does not support the growth of fungus. Any parts which are susceptible to the growth of fungus will require special treatment.

Freeze-Tested Circuit BreakersThe circuit breakers may be ordered with freeze testing. This option uses special lubrication and mechanical operation is verified at -40°C.

Marine ApplicationsF-Frame circuit breakers can be sup-plied to meet the following marine specifications:

■ U.S. Coast Guard CFR 46 ABS — American Bureau of Shipping IEEE 45

These specifications generally require molded case circuit breakers to be supplied with 50°C ambient calibration, special nameplating, and plug-in adapter kits. When plug-in adapter kits are used, no terminals need be supplied.

Circuit breakers can also be supplied to meet UL489 Supplement SA (Marine Use) and UL489 Supplement SB (Naval Use).

UL489 Supplement SA applies to vessels over 65 feet in length. Requirements include 40°C ambient calibration, spe-cial labeling, and no use of aluminum conductors or terminals.

UL 489 Supplement SB requires 50°C ambient calibration, vibration testings, special nameplating and no use of aluminum conductors or terminals.

Standards and CertificationsMolded case circuit breakers are designed to conform with the follow-ing standards:

■ Underwriters Laboratories, Inc., Standard UL489, Molded Case Circuit Breakers and Circuit Breaker Enclosures

■ National Electrical Manufacturers Association Standards Publication No. AB1-1993, Molded Case Circuit Breakers

■ Australian Standard AS 2184, Molded Case Circuit Breakers

■ British Standards Institution Standard BS 4752: Part 1, Switchgear and Control Gear Part 1: Circuit Breakers

■ Canadian Standards Association Standard C22.2 No. 5, Service Entrance and Branch Circuit Breakers

■ International Electrotechnical Commission Recommendations IEC 157-1, Circuit Breakers

■ Japanese T-Mark Standard Molded Case Circuit Breakers

■ South African Bureau of Standards, Standard SABS 156, Standard Specification for Molded Case Circuit Breakers

■ Swiss Electro-Technical Association Standard SEV 157-1, Safety Regula-tions for Circuit Breakers

■ Union Technique de l’Electricite Standard NF C 63-120, Low Voltage Switchgear and Control Gear Circuit Breaker Requirements

■ Verband Deutscher Elektrotechniker (Association of German Electrical Engineers) Standard VDE 0660, Low Voltage Switchgear and Control Gear, Circuit Breakers

Conformance with these standards satisfies most local and international codes, assuming user acceptability and simplified application.

Molded case circuit breakers equal or exceed Federal Specification Classifi-cation W-C-375b requirements for the particular class associated with the cir-cuit breaker frame being considered.

Note: For further information, see Circuit Breaker, CD-ROM SA.74A.01.T.E.

Suffix H01 400 Hz 20% Adder

Suffix J01 Fungus Treated $325. + 20% Adder

Suffix F01 Freeze Tested 20% Adder

Suffix H08 “Marine” 10% Adder

Suffix H09 “Naval” 10% Adder

Page 3: 12-22 Molded Case Circuit Breakers Cutler-Hammer · 2015. 7. 16. · 12-22 Molded Case Circuit Breakers 10-225 Amperes F-Frame Cutler-Hammer January 2001 Vol. 1,Ref. No. [0488] Table

CAT.200.01.T.E For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog

12January 2001 Product Line OverviewVol. 1, Ref. No. [0469]

Quick ReferenceTable 12-1. Industrial Circuit Breakers

� N.I.T. is non-interchangeable trip unit and I.T. is interchangeable trip unit.� Two-pole circuit breaker, or two poles of three-pole circuit breaker at 250V DC.� Not defined in W-C-375b.

CircuitBreakerType

Cont.Amp.Rating@ 40°C

No.Poles

Volts Type of Trip �

Federal Spec.W-C-375b

UL Listed Interrupting Ratings rms Symmetrical Amperes PageNumberAC DC AC Ratings Volts DC �

120 120/240 240 277 480 600 125 250 125/250

G-FrameGBGB

15 – 10015 – 100

12, 3

120240

125125/250

N.I.T. 11a10b, 11b, 12b, 14b, 15b

65,000 —

——

—65,000

——

——

——

14,000—

——

—14,000

12-912-9

GHBGHBGHBGHBHGHBGQ

15 – 10015 – 10015 – 10015 – 10015 – 3015 – 20

12, 312, 311

120240277277/480277277

125125/250125125/250125—

N.I.T. 11a10b, 11b, 12b, 14b, 15b12c, 13a, 13b

65,000 ———65,00065,000

——————

—65,000————

——14,00014,000 25,00014,000

———14,000——

——————

14,000—14,000—14,000—

——————

—14,000 —14,000——

12-912-912-912-912-912-9

GHBSGBHS

15 – 3015 – 20

1, 21, 2

277/480347/600

——

—N.I.T.

——

65,000—

65,000—

——

14,000—

——

—10,000

——

——

——

11-1411-14

GCGC

15 – 10015 – 100

12, 3

120240

125125/250

N.I.T. 11a10b, 11b, 12b, 14b, 15b

65,000 —

——

—65,000

——

——

——

14,000—

——

—14,000

12-1112-11

GDGD

15 – 5015 – 100

23

480480

125/250250

N.I.T.N.I.T.

13b13b

——

——

65,00065,000

——

14,00022,000

——

——

—10,000

10,000—

12-812-8

GHCGHCGHCGHCHGHC

15 – 10015 – 10015 – 10015 – 10015 – 30

12, 312, 31

120240277277/480277

125125/250125125/250125

N.I.T. 12c, 13a13b12c, 13a13b

65,000 ———65,000

—————

—65,000———

——14,00014,000 25,000

———14,000—

—————

14,000—14,000—14,000

—————

—14,000—14,000—

12-1112-1112-1112-1112-11

New E125 FrameE125B 15 – 125 1

2, 3, 4277480

250 N.I.T. ——

35,000—

——

25,00025,000

18,000—

—18,000

——

10,000—

—10,000

——

12-16

E125E 15 – 125 2, 3, 4 600Y/347 250 N.I.T. — — — 35,000 — 25,000 18,000 10,000 10,000 — 12-16

E125S 15 – 125 12, 3, 4

347600Y/347

250 N.I.T.N.I.T.

——

100,000—

——

85,00085,000

35,000—

—35,000

—22,000

35,000—

—35,000

——

12-16

E125H 15 – 125 12, 3, 4

347600Y/347

250 N.I.T. ——

200,000—

——

100,000100,000

65,000—

—65,000

—25,000

42,000—

—42,000

——

12-17

F-FrameEDEDHEDC

100 – 225100 – 225100 – 225

2, 32, 32, 3

240240240

125125125

N.I.T. 12b14b1

———

———

65,000100,000200,000

———

———

———

10,00010,00010,000

———

———

12-2112-2112-21

EHDEHD

15 – 10015 – 100

12, 3

277480

125250

N.I.T. 13a13b

——

——

—18,000

14,000—

—14,000

——

10,000—

—10,000

——

12-2112-21

FDBFDB

15 – 15015 – 150

2, 34

600600

250250

N.I.T. 18a�

— —

——

18,00018,000

——

14,00014,000

14,00014,000

——

10,00010,000

——

12-2212-22

FDFDFD

15 – 22515 – 22515 – 225

12, 34

277600600

125250250

N.I.T. 13a22a�

— ——

— ——

—65,00065,000

25,000——

—25,00025,000

—18,00018,000

10,000——

—10,00010,000

— ——

12-2212-2212-22

HFDHFDHFD

15 – 22515 – 22515 – 225

12,3 4

277600600

125250250

N.I.T. 13a22a�

— ——

— ——

—100,000100,000

65,000——

—65,00065,000

—25,00025,000

10,000——

—22,00022,000

— ——

12-2212-2212-22

FDCFDC

15 – 22515 – 225

2, 3 4

600600

250250

N.I.T. 24a�

— —

— —

200,000200,000

— —

100,000100,000

35,00035,000

— —

22,00022,000

— —

12-2212-22

New J250 FrameJ250EJ250SJ250H

63 – 25063 – 25063 – 250

2, 3, 42, 3, 42, 3, 4

600600600

250250250

I.TI.TI.T

———

— ——

— ——

65,00085,000

100,000

———

25,00035,00065,000

18,00018,00025,000

———

10,00022,00022,000

— ——

12-2812-2812-28

Page 4: 12-22 Molded Case Circuit Breakers Cutler-Hammer · 2015. 7. 16. · 12-22 Molded Case Circuit Breakers 10-225 Amperes F-Frame Cutler-Hammer January 2001 Vol. 1,Ref. No. [0488] Table

Cutler-HammerJanuary 2001Vol. 1, Ref. No. [0485]

Molded Case Circuit Breakers10-225 AmperesF-Frame

12-19

ContentsDescription

Product Description

Technical Dataand Specifications

Dimension/Weights

Product Selection ..

F-FramePage

12-19

12-1912-2012-20

Product Description• All F-Frame Circuit Breakers are

HACR rated.• All circuit breakers 10 through

50 amperes are suitable for HID(high intensity discharge) use.

• All F-Frame circuit breakers aresuitable for reverse feed use.

Typical F-Frame Breaker

Technical Data and SpecificationsTable 12-28. UL489 Interrupting Capacity RatingsCircuitBreakerType

EDEDHEDCEHD

FOBFD

HFD

FDC

Numberof Poles

2,32,32,312,32,3,412,3,412,3,42,3,4

Interrupting Capacity (Symmetrical Amperes) (kA)Volts AC (50/60 Hz)240

65100200

1818

65

100200

277

14

—25

65

480

1414

25

65100

600

_

14

18

2535

Volts DC &125

10101 01 0

—10

10

250 @®

1 010

1 0

2222

© DC ratings apply to substantially non-inductive circuits.® 2-pole circuit breaker, or two poles of 3-pole circuit breaker.® Time constant is 3 milliseconds minimum at 10 kA and 8 milliseconds minimum at 22 kA.

Table 12-29. IEC 157-1 (PI) Interrupting Capacity Ratings (P1)

CircuitBreakerType

EDEDHEDCFOBFD

HFD

FDC

Number ofPoles

2,32,32,32,3,4

12,3,412,3,4

2,3,4

Interrupting Capacity (Symmetrical Amperes) (kA)Volts AC (50/60 Hz)220, 240

65100200

18

2565

65100

200

380,415

14

35

65

100

440

14

35

65

100

500

14

18

25

35

Volts DC A125

101010

—10

10

250 @®

10

10

22

22

® DC ratings apply to substantially non-inductive circuits.® 2-pole circuit breaker, or two poles of 3-pole circuit breaker.© Time constant is 3 milliseconds minimum at 10 kA and 8 milliseconds minimum at 22 kA.

CAT.200.01.T.E For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog F.T.N

Page 5: 12-22 Molded Case Circuit Breakers Cutler-Hammer · 2015. 7. 16. · 12-22 Molded Case Circuit Breakers 10-225 Amperes F-Frame Cutler-Hammer January 2001 Vol. 1,Ref. No. [0488] Table

12-20 Molded Case Circuit Breakers10-225 AmperesF-Frame .. f-i -i

Cutler-HammerJanuary 2001

Vol. 1, Ref. No. [0486J

Dimensions/WeightsTable 12-30. Dimensions in Inches (mm)Numberof Poles

12

34

Width

1.375(35)2.75 (70)

4.125(105)5.5(140)

Height

6(152)6(152)

6(152)6(152)

Depth

3.375 (86)3.375 (86)

3.375 (86)3.375 (86)

Table 12-31. Approximate Shipping Weight, Lbs. (Kg)Breaker Type

ED, EDH, EDC

EHD, FOB, FD, HFD, FDC

Number of Poles1

—2 (.907)

2 3

3(1.361)

3(1.361)

4.5(2.041)

4.5(2.041)

4

6(2.721)

Product SelectionThis information is presented only as an aid to understanding Catalog Numbers. It is not to be used to build Catalog Numbersfor circuit breakers or trip units.

Table 12-32. Circuit Breaker Catalog Numbering System

FDC 3 100 L

Circuit BreakerType

EHDFOBFDHFDFDC

Numberof Poles

1 = 1 Pole2 = 2 Poles3 = 3 Poles4 = 4 Poles

Trip Ar

010015020025030035

J

0450500600700800901001 1 0125150175 (FD,200 (FD,225 (FD,

HFD, FDC, 2-, 3-, 4-Pole Only)HFD, FDC, 2-, 3-, 4-Pole Only)HFD, FDC, 2-, 3-, 4-Pole Only)

Circuit BreakerType

EDEDHEDC

Numberof Poles

2 = 2-Pole3 = 3-Pole

200

SuffixE = 100% Protected (4-Pole only) Neutral PoleEH = 50% Protected (4-Pole only)K = High Magnetic Molded Case SwitchL = Line and Load TerminalsS = Stainless Steel TerminalsV = 50°C CalibrationW = Without TerminalsY = Line Terminals OnlyZ = Aluminum Terminals (< 100 Amperes)

SuffixL = Line and Load TerminalsW = Without TerminalsY = Line Terminals OnlyZ = Aluminum Terminals (100 Amperes)

X

E:T*M For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.200.01.T.E

Page 6: 12-22 Molded Case Circuit Breakers Cutler-Hammer · 2015. 7. 16. · 12-22 Molded Case Circuit Breakers 10-225 Amperes F-Frame Cutler-Hammer January 2001 Vol. 1,Ref. No. [0488] Table

Cutler-HammerJanuary 2001Vol. 1, Ref. No. I0489]

Molded Case Circuit Breakers10-225 AmperesF-Frame

12-23

Molded Case SwitchesMolded Case Switches are used ascompact switches in applicationsrequiring high current switchingcapabilities. Molded case switchesare constructed of circuit breakercomponents and are of the highinstantaneous automatic type. Moldedcase switches are listed in accordancewith Underwriters Laboratories, Inc.,Standard UL 1087.

Line and Load TerminalsLine and Load Terminals provide wireconnecting capabilities for specificranges of continuous current ratingsand wire types. Except as noted,terminals comply with UnderwritersLaboratories, Inc., Standards UL486Aand UL486B. Unless otherwisespecified, F-Frame circuit breakersare factory equipped with loadterminals only.

Ordering InformationF-Frame circuit breakers and moldedcase switches have load terminalsonly as standard equipment. Whenstandard line-end terminals (same asstandard load-end terminals) arerequired, add Suffix L to the circuitbreaker Catalog Number. When non-standard or optional line and/or loadterminals are required, order by stylenumber. Specify if factory installationis required.

Table 12-37. Molded Case SwitchesMaximumContinuousAmpere Rating@40°C

480V AC Maximum,250V DCComplete Circuit Breakerwith Load Side Terminals OnlyCatalogNumber

PriceU.S. S

600V AC Maximum,250V DCComplete Circuit Breakerwith Load Side Terminals OnlyCatalogNumber

PriceU.S. $

2-Pole100150225

EHD2100K 476. FD2100KFD2150KFD2225K

535.001,135.001,135.00

3-Pole100150225

EHD3100K 570. FD3100KFD3150KFD3225K

665.001,240.001,190.00

4-Pole100150225 E —

FD4100KFD4150KFD4225K

930.001,735.001,665.00

Note: Molded Case Switches may open above 1800 amperes.Note: Instruction Leaflet/FRED Number 29C101

Table 12-38. Line and Load TerminalsMaximumBreakerAmperes

Terminal BodyMaterial

Wire Type AWG WireRange

Metric WireRange mm2

Package of 3 TerminalsCatalogNumber

PriceU.S. $

Standard Pressure Type Terminals20 (END)

100225

SteelSteelAluminum

Cu/AICu/AICu/AI

14-1014-1/014-4/0

2.5- 42.5- 50

25 - 95

3T20FB ©3T100FB3TA225FD

6.106.10

89.00Optional Pressure Terminals

50100200225

AluminumAluminumStainless SteelAluminum

Cu/AICu/AICuCu/AI

14-414-1/04-4/06 - 300 kcmil

2.5- 252.5- 50

25 - 9516 -150

3TA50FB ®3TA100FD3T150FB3TA225FDK i

6.106.106.10

89.00® Not for use with ED, EDH, EDC breakers.® Includes terminal shield kit. Adds approximately 3 inches (76.2) to breaker height. Available for

use on 3-pole breaker only.

Discount Symbol. CB-2

CAT.200.01.T.E For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog E:t>N