Text of 20 feet Containerized Solution Specifications CSCU 3024635
2 Legal Provisions No part of this User Manual (“Manual”) may be reproduced, or transmitted, in any form or by any means, without the prior written permission of Kilowatt Labs, Inc. (“Kilowatt” or the “Company”). Specifications in this Manual are subject to change without notice. While every attempt has been made to make the Manual accurate and up-to-date, users are cautioned that product improvements may cause the Company to make changes to specifications without advance notice. Users are encouraged to consult the Company or its Resellers before using the Manual. Neither the Company nor its Resellers shall be liable for any indirect, incidental, or consequential damages under any circumstances caused by reliance on the material presented, including, but not limited to, omissions, typographical errors, arithmetical errors or listing errors in the content material. The content of this manual shall not be modified without the written authorization of the Company. Trademarks All trademarks are recognized, even if not explicitly identified as such. Kilowatt Labs® is a registered trademark of the Company. Warning Selling and installation of this product is only through the Company’s Resellers who are trained on installation, operation and maintenance of the Sirius modules. Sam ple 2 Sirius Capacitor Module 1.36kWh, 2.4V 150 PCS 3 Monitoring Machine UPS (600VA) & Battery (465Wh) 1 Set CPU 1 PC MAIN Distribution Panel Switch SBN440, 4P 40 A 1 PC Switch CEC441J, 4P 40 A 1 PC MCB MCN116A, 1P 6kVA C-16A 1M 3 PCS MCB MCN132A, 1P 6kVA C-32A 1M 3 PCS Output DB Panel MCCB, ABS104c, 125 Ah 1 PC Generator Panel MCCB, ABS104c, 125Ah 1 PC 5 Isolator Switch 1P, 35 A, 250V 1 PC 6 Fire Extinguisher Automatic Dry Power Fire Extinguisher 2 PC 8 Embedded NVR DS-7600 Series NVR 1 PC 9 Module Sensor PBAT 802 150 PCS 10 Sensor Combiner PBAT 600 3 PCS 11 Communication Gate Way PBAT GATE 1 PC 14 Motion Sensor 1 Set Sam ple Total Energy 204600 Wh ENVIRONMENTAL SPECIFICATIONS Operating Humidity Non-Condensing cell monitoring, Current and Energy Remote control (optional) Via Sirius Remote Control Communication and Connectivity Ethernet/RS 485 Alarm Audible alarm in the event of Over/under-Voltage, Over-Current, Over Temperature Graphs, Daily reports and data logging System Monitoring Consumption Solar Energy, Total Generated Solar energy from the start, Daily Consumption Energy down down down COMPLIANCE8 INFORMATION PRECAUTIONS Alarm In case of alarm, immediately rectify/attend to the cause of the alarm. Physical Damage In case the Module is physically damaged due to any event, do not install and energize the Module under any circumstances and contact your Reseller. Short Circuit Ensure precautions to prevent short-circuit under all circumstances. Galvanic isolation When connecting to external devices ensure that galvanic isolation does not exceed 1000V. 15 Recessed box 17 Sockets Standard Socket 2 Set 18 Lights Fluorescent Light Tube 3 PCS 19 Exit Light 2 PC Sam ple Under no circumstances must the charge/discharge current exceed 60A. Charging Voltage Under no circumstances must the charging voltage exceed 405 Vdc for more than 60 seconds. Charge Cycle During charge cycle ensure never to exceed constant voltage of 405 Vdc and constant current of 60A. 1Self-discharge is the natural decay of the Module total voltage over time. Module self-discharge is 2% in Sleep Mode (switched off) and 9.6% in Switched-On Mode. 2The Module C-Rate refers to the rate at which a Module is charged or discharged. A 1C rate means that the current will charge or discharge the entire Module in 1 hour. 3The temperature range indicates the range in which the supercapacitor cells can operate. The performance of the cells may vary if they are continuously operated outside a temperature range of -10C to 55C, and/or at C-rates higher than the maximum charge/discharge rate specified in this spec sheet. The operating temperature range of the Module varies based on the application. If the Module is to be operated continuously outside a temperature range of -10oC to 55oC, and/or at C- rates higher than the maximum charge/discharge rate specified in the spec sheet, please consult Kilowatt Labs or its Reseller prior to deploying. 4Projected life of supercapacitor cells. Cycle life will vary if cycled more than 4 times a day. 5Additional terms and conditions, including a limited warranty, will apply at the time of purchase. 6Projected Calendar life of supercapacitor cells from the date of first operation. 7Shelf life is the life of the Module (in years) from the date it is manufactured to the time it is first operated. 8CE certification is completed for supercapacitor cells. Product dimensions are for reference only unless otherwise identified and may change without notice. For critical applications, please contact your Reseller. Sam ple Battery voltage 360 Vdc PV INPUT Optimum operating voltage (Vamp) 450 ~ 550 Vdc Max. conversion efficiency ≥ 98% MPPT Max. current 120 A Max. PV power 2 * 25 KW Number of PV input 2 + 1 (reserve) MPPT modules 2 + 1 (reserve) AC RECTIFIER Rated frequency 50 Hz / 60 Hz ± 5 Hz (settable) Power factor 0.8 Max. charging current 38 A INVERTER Sam ple Rated frequency 50 Hz / 60 Hz ± 1 Hz (settable) Frequency tracking range 50 Hz / 60 Hz ± 3 Hz Peak factor 3: 1 Voltage unbalance ± 3% (100% unbalanced load) Overload ≥ 105% ~ 110% for 1 hr: ≥ 110% ~ 125% for 10 mins; ≥ 125% ~ 150% for 1 min; ≥ 150% shut down in 10 s; ≥ 200% shut down immediately; start up Voltage range ± 20% Max. current 57 A EPO, battery self-test Dry contacts output Bypass input abnormal, rectifier input abnormal, system fault, system alarm, low battery, output overload, fan fault, generator ON / OFF Load Handling Curve Max. relative humidity 90% (non-condensing) Max. altitude 1000 m at rated power (derating 1% for each additional 100 m); Max. 4000 m Sam ple 11 Noise level at 1 m ≤ 65 dB (varies with loads and temperature) IP rating IP20 Packaged dimensions (W ×D × H) (mm) 690 × 790 × 1850 Weight (kg) 380 Part No. 1364-2.4-B-0.53C-TM-SD-A-CS Total Energy 1364 Wh ENVIRONMENTAL SPECIFICATIONS Operating Humidity Non-Condensing and Energy Remote control (optional) Via Sirius Remote Control Communication and Connectivity Ethernet Over/under-Voltage, Over-Current, Over Temperature Total Energy delivered, Graphs parallel or series) MODULE SERVICE LIFE Projected Calendar Life5,6 45 years Shelf Life7 10 years affecting cycle life down down down PRECAUTIONS Alarm In case of alarm, immediately rectify/attend to the cause of the alarm. Physical Damage In case the Module is physically damaged due to any event, do not install and energize the Module under any circumstances and contact your Reseller. Short Circuit Ensure precautions to prevent short-circuit under all circumstances. Galvanic isolation When connecting to external devices ensure that galvanic isolation does not exceed 1000V. Charge/Discharge Current Under no circumstances must the charge/discharge current exceed 300A. Charging Voltage Under no circumstances must the charging voltage exceed 2.7 Vdc for more than 60 seconds. Charge Cycle During charge cycle ensure never to exceed constant voltage of 2.7 Vdc and constant current of 300A. 1Self-discharge is the natural decay of the Module total voltage over time. Module self-discharge is 2% in Sleep Mode (switched off) and 9.6% in Switched-On Mode. 2The Module C-Rate refers to the rate at which a Module is charged or discharged. A 1C rate means that the current will charge or discharge the entire Module in 1 hour. 3The temperature range indicates the range in which the supercapacitor cells can operate. The performance of the cells may vary if they are continuously operated outside a temperature range of -10C to 55C, and/or at C-rates higher than the maximum charge/discharge rate specified in this spec sheet. The operating temperature range of the Module varies based on the application. If the Module is to be operated continuously outside a temperature range of -10oC to 55oC, and/or at C-rates higher than the maximum charge/discharge rate specified in the spec sheet, please consult Kilowatt Labs or its Reseller prior to deploying. 4Projected life of supercapacitor cells. Cycle life will vary if cycled more than 4 times a day. 5Additional terms and conditions, including a limited warranty, will apply at the time of purchase. 6Projected Calendar life of supercapacitor cells from the date of first operation. 7Shelf life is the life of the Module (in years) from the date it is manufactured to the time it is first operated. 8CE certification is completed for supercapacitor cells. Product dimensions are for reference only unless otherwise identified and may change without notice. For critical applications, please contact your Reseller. Sam ple Auxiliary Supply UPS Model 600VA Input mode Inverter mode BLU mode Rated values Input frequency range 38~70Hz Output voltage Mains mode ESD mode 220V±5% (resistive load) Output frequency ESD mode 50HZ±1Hz Waveform Mains mode Tracking mains power ESD mode Sine wave Output power factor 0.8 Output power 600VA/480W Protection Over temperature protection When heatsink temperature exceeds 90ºC: Shut down charger in mains mode, and shut down inverter in ESD mode Over voltage protection Shut down output when the voltage is above 285+/-10V Under voltage protection Shut down output when the voltage is below 120+/-10V LCD Monitor Monitoring CPU Dielectric strength 2820Vdc Overload capacity (precision: +/- 10%) 1. Mains mode: 1) 100% load, long term operation. 2) 100~120% shut down output after 3min, re-startup automatically after 30s, after re-startup 3 times, if the overload still exists, then enter failure mode and the unit needs to be started up manually. 3) 120~130% shut down output after 30s, re-startup automatically after 30s, after re-startup 3 times, if the overload still exists, then enter failure mode and the unit needs to be started up manually. 4) ≥130% shut down output immediately, re-startup automatically after 30s, after re-startup 3 times, if the overload still exists, then enter failure mode and the unit needs to be started up manually. 2. ESD mode: 1) 100% load, long term operation. 2) 100~110% shut down output after 10s, re-startup automatically after 30s (with soft startup), after re-startup 3 times, if the overload still exists, then enter failure mode and the unit needs to be started up manually. 3) ≥110% shut down output immediately, re-startup automatically after 30s (with soft startup), after re-startup 3 times, if the overload still exists, then enter failure mode and the unit needs to be started up manually. Rated ESD voltage Mechanical Specifications Unit Dimensions reference to GB7260.3-2003 4.1.1 Total Energy 465 Wh ENVIRONMENTAL SPECIFICATIONS Operating Humidity Non-Condensing Projected Calendar Life5,6 45 years Shelf Life7 10 years affecting cycle life PRECAUTIONS Physical Damage In case the Module is physically damaged due to any event, do not install and energize the Module under any circumstances and contact your Reseller. Short Circuit Ensure precautions to prevent short-circuit under all circumstances. Galvanic isolation When connecting to external devices ensure that galvanic isolation does not exceed 1000V. Charge/Discharge Current Under no circumstances must the charge/discharge current exceed 70A. Charging Voltage Under no circumstances must the charging voltage exceed 13.5 Vdc for more than 60 seconds. Charge Cycle During charge cycle ensure never to exceed constant voltage of 13.5 Vdc and constant current of 70 A. 3.2 Monitoring CPU: Operating System Windows 10 Pro Memory Up to 32 GB 2 DDR4 UDIMM 2400MHz Storage • 2280 M.2 PCIe SSD (up to 256 GB) • 3.5" HDD (up to 1 TB) • 2.5" SSD (up to 128 GB) • Slim ODD • Intel Integrated HD Graphics 610 Sam ple PSU 180W/210W PSU CONNECTIVITY • Card reader (optional) • 2 x audio Rear I/O Ports • 1 x serial, 1 x optional serial • Optional parallel port • LAN CERTIFICATIONS Green Certifications • Energy Star 6.1 • RoHS/WEEE/REACH DESIGN Dimensions (W x D x H) 92.5 mm × 290.9 mm × 343.5 mm / 3.64" x 11.45" x 13.52" SOFTWARE Preloaded Software • Lenovo App Explorer • Lenovo Companion 3.0 Aspect Ratio 5: 4 Resolution 1280 x 1024 Response Time 5ms (On/Off) Surface Treatment Non glare PHYSICAL FEATURES Set (with Stand, W x D x H, mm) 370 x 95 x 315 Set (without Stand, W x D x H, mm) 370 x 62 x 315 Box (W x D x H, mm) 429 x 159 x 377 Sam ple Box(kg) 4.5 Set (with Stand, W x D x H, mm) 370 x 95 x 315 SPECIAL FEATURES STAND Swivel (Angle) - ENERGY RATINGS Regulation Compliance TUV-Type, FCC-B, CE, C-Tick, CB, MEPS VESA Mount, Windows7 MCCB ABS104c - - 1 PC Output DB Panel Rated operational Voltage 250 V Rated Insulation Voltage 250 V Rated Impulse-withstand Voltage (Uimp) 2.5 KV Frequency 50 / 60 Hz Pollution Degree 3 Contact Opening Type Normal Gap Switch Actuating Method Manual Operation Method of mounting Surface Type of Enclosure Enclosed Sam ple SPECIFICATION MODEL FE36 Capacity (kg) 6 Fire rating 21a Empty weight (kg) 6 Total weight (kg) 15 Hose automatic type Extinguishing agent hfc-236fa Cylinder material cold rolled steel Painting super finished electro plastic polyester epoxy resin Mounting ceiling mounted Key Features: 1/2.8″ progressive scan CMOS Up to 2.0 megapixel 2.8mm/4mm/6mm fixed focal lens Up to 30 m IR range Dual stream Digital WDR (Wide Dynamic Range) 3D DNR (Digital Noise Reduction) PoE (Power over Ethernet) IP67, IK10 Mobile monitoring via Hik-Conn Sensor CMOS Image Sensor S/N Ratio 62dB Minimum illumination Color: 0.01 Lux @ (F1.2, AGC ON), 0 Lux with IR Shutter Speed 1/3 s to 1/100, 000 s, support slow shutter Weight 500g Sam ple Key Features - 4 Channel PoE IP Camera Ports - Support for up to 8MP recording and playback - Support for 4k video output - H.264/H.264+/H.265 video codecs - 1 SATA interface to connect 1 x 10TB hard drive - Support for VCA detection alarm - Compatible with third-party IP cameras - Supports Hikvision's ANPR solutions Number of Channels 4 Incoming Bandwidth 40 Mbps Outgoing Bandwidth 80 Mbps Number of Bays 1 14. Motion Sensor: 15. Recessed box: 1 Recessed Box with 63A Industrial socket and Plug(5-pin) and 6 number of 50mm dia holes for cable entry. 16. Double Sockets: 17. Double LED light: 18. Exit Light (ROBUS R8MLED-01): Power Consumption (W) 2.6 Batteries (NiCad) 3.6v 1.5Ah Light output in emergency (lm) 60 Ambient Temperature Range (0C) 0 ≤ Ta ≤ +25 IP Rating 65 Weight (Kg) 0.57