    A beautiu ascape is gree.So is a heathy IT ascape.

    Our services for energy efciencyin the data centre.

    IndUSTRIAl SERVICES GREEn IT

    www.tuv.com

  • 7/29/2019 2011 G

    2/8

    We bring Green IT to your data centre

    perectly measured, analysed andeciently controlled.

  • 7/29/2019 2011 G

    3/8

    Icreasig voume o ata,eergy prices a costs.

    Computing power consumes electricity: energy for data

    processing, cooling and also uninterruptible power

    supply. Let TV Rheinland guide your company along

    the path to higher energy efciency and lower CO2

    emissions through our comprehensive approach toanalysis and monitoring.

    We concentrate on applying an integrated approach

    to your data centre. That means analysing the HVAC

    system, power supply, IT environment and other power

    consumers such as lighting, re protection, etc.

    Using measurements and analyses of the actual condi-

    tion, we determine the improvement potential. Our

    survey also takes management and communication

    structures into account. This makes it possible to createoptimised processes that lead to continuous improve-

    ment, thereby sustainably ensuring optimised condi-

    tions in terms of energy consumption.

    Working together with you, we then initiate measures

    from the potential improvements which have beenidentied. The goal is to reduce energy consumption

    in the data centre and to cut energy costs through

    consistent implementation of the dended measures

    year after year.

    We conduct annual audits in order to monitor the ef-

    fectiveness of the measures implemented and use new

    ideas to help maintain the conguration of your data

    centre at the current state-of-the-art. In this way, you

    take advantage of our expertise over the long term.

  • 7/29/2019 2011 G

    4/8

    Rage o services.

    1. Energy technology assessmentThe assessment is used to determine the actual state

    and to prepare an optimisation concept.

    It contains:

    Efciency check with review of documents, inspectionof the data centre, pre-audit based on TV Rheinlands

    list of criteria, and short report with estimations of

    improvement potential

    Measurements of energy consumption, heat ows, air-

    ows, etc.

    Recording of heat distributionsAnalysis of energy consumers

    Analysis of HVAC and heat dissipation

    Development of improvement measures

    Concept design (alternative concepts, if necessary)

    Report with denition, evaluation and possiblequantication of the improvement potential

    The beefts.

    You identify the actual electrical consumption of

    your IT landscape.

    You receive competent advice on the best ways to

    increase efciency.

    You permanently reduce energy costs.

    Your certicate serves as documentary proof of yourCorporate Social Responsibility (CSR).

  • 7/29/2019 2011 G

    5/8

    2. MeasurementsA solid assessment can only be made on the basis o

    measurement values. As a supplement to the existing

    energy data, we oer you the ollowing measurements:

    Blower door testUsing a blower door test to check the tightness of the

    building or shell reveals any existing weaknesses. This is

    particularly important where re protection is provided

    by means of an oxygen-reduced atmosphere or if air-

    circulating climate control systems are used.

    Thermography and airfow measurement

    In order to identify temperature-critical areas, we offer

    thermographic recordings and occasional airow measure-

    ments for the visualisation of air movement.

    Flow and heat measurement

    For the evaluation of the cooling systems, the quantity of

    heat carried away in the cooling water circuit is recorded

    by means of an ultrasonic ow meter.

    Short-term measurements o electrical power

    Short-term measurements (spot measurements) of the

    electrical power drawn by the major consumers make it

    possible to estimate the energy ows. These measure-

    ments are carried out by means of inductive, non-contact

    transducers without the need to interrupt operation.

    Long-term measurements o electrical power

    A continuous measurement of electrical power provides

    the advantage that variations in consumption are also

    recorded. This prevents any temporary drops or peaks

    from distorting the measured values.

  • 7/29/2019 2011 G

    6/8

    Certication audit

    Certication

    3. Energy-Efcient data CentreCertication by TV Rheinland enables you to syste-

    matically achieve a sustained improvement of the en-

    ergy efciency of your data centre.

    Prerequisites in preparation or certication:The most important measures for an energy-efcient

    operation are met, i. e. at least 60 % of the possible

    evaluation points of the criteria catalogue are achieved.

    Instruments for monitoring, for analysis and for im-

    plementation of measures to raise efciency are esta-

    blished in the data centre.

    Assessment

    Certif

    cation

    Efciency check

    Short-term measurements

    List of measures

    Organisational andtechnical optimisation

    Short-termmeasurements

    Long-term measurements

    Comprehensive

    expert assessment

    Implemen

    tation

    Repeatcertifcationater1year

  • 7/29/2019 2011 G

    7/8

    Those who cacuate efcietyicue us i their cacuatios.

    The sustainable use of energy is an overarching topic.

    In the eld of information and communication tech-

    nology, this idea is expressed by the term Green IT.

    Data centres in particular require large quantities of

    electrical energy. This translates into high operating

    costs and adversely impacts the CO2 balance of the

    company. In this connection, it has been determined

    that the electrical consumption of data centres repre-

    sents a 1.8 % share of the total electrical consumption

    in Germany. In other words, servers and data centresalone consume the combined output of four coal-red

    power plants.

    More than 50 % of the energy in data centres is used

    to operate the systems (air-conditioning, ventilation,

    safety systems, lighting, etc.). In order to achieve energy-

    savings here, these energy consumption rates must be

    determined. In many cases, no measurement data are

    available and separate responsibilities make it even

    more difcult to identify solutions. This is where the

    experts from TV Rheinland intervene and point outopportunities to permanently increase efciency.

    TUVotCOM. The oticeabe ierece.

    The Internet platform TUVdotCOM

    illustrates the difference: Products,

    services, companies, systems and

    personnel tested by TV Rheinland

    are optimally documented andaccessible from all over the world.

  • 7/29/2019 2011 G

    8/8

    TV,

    TUEVandTUVareregisteredtradema

    rks.

    Anyandallu

    sesofthes

    etrademarksrequirepermiss

    ion.

    1614.0

    2.1

    1

    TV Rheia

    Eergie u Umwet GmbH

    Am Graue Stei

    51105 Cooge, GermayPhoe +49 1803 252535-1600*

    Fax +49 1803 252535-1699*

    [email protected]

    www.tuv.com

    * 9 euro cets/mi. rom aie i

    Germay, mobie max. 42 euro cets/mi.