21M51U-843 & 21M51U-843 & 21V51U-843 21V51U-843 Universal – Integrated Ignition Control Kit

21 V51 U 843 & 21 M51 U 843 Presentation (Web Ex) Rev. I

Embed Size (px)

DESCRIPTION

New Wholesale Universal Two Stage IFC Kits: I developed and launched these products.

Citation preview

Page 1: 21 V51 U 843 & 21 M51 U 843 Presentation (Web Ex) Rev. I

21M51U-843 & 21M51U-843 & 21V51U-84321V51U-84321M51U-843 & 21M51U-843 & 21V51U-84321V51U-843Universal – Integrated Ignition Control Kit

Page 2: 21 V51 U 843 & 21 M51 U 843 Presentation (Web Ex) Rev. I

AgendaAgendaAgendaAgenda Product Knowledge/Familiarization: 1.) Kit Contents 2.) Contractors Feedback: - Why is the kit containing a 21D64-2 ignitor kit? 3.) Key Selling Points: - Why a new kit? - Features - Competition - Replacement Percentage by OEM and Part No. - Easy of Setup 4.) Supporting Launch: -Spec Sheets -Product Announcement 4 Key Take Aways

Page 3: 21 V51 U 843 & 21 M51 U 843 Presentation (Web Ex) Rev. I

How the 21M51U-843 How the 21M51U-843 (PSC) (PSC) Kit is packaged. Kit is packaged. How the 21M51U-843 How the 21M51U-843 (PSC) (PSC) Kit is packaged. Kit is packaged.

3 Emerson Confidential

50M51-843Module

21D64-2Ignitor

InstructionSheets (hidden)

Page 4: 21 V51 U 843 & 21 M51 U 843 Presentation (Web Ex) Rev. I

4 Emerson Confidential

50V51-843Module

21D64-2Ignitor

InstructionSheets (hidden)

Harnesses (For Goodman Only)

How the 21V51U-843 How the 21V51U-843 (Variable Speed) (Variable Speed) Kit is packaged. Kit is packaged.

How the 21V51U-843 How the 21V51U-843 (Variable Speed) (Variable Speed) Kit is packaged. Kit is packaged.

Page 5: 21 V51 U 843 & 21 M51 U 843 Presentation (Web Ex) Rev. I

5 Emerson Confidential

Based on WR’s contractor survey:

50% of the contractors prefer to include the ignitor in the kit

and 26% of the contractors replace the ignitor when

replacing the control

Answer: We included the 21D64-2 in the kit.

Results From Contractor SurveyResults From Contractor SurveyResults From Contractor SurveyResults From Contractor Survey

Page 6: 21 V51 U 843 & 21 M51 U 843 Presentation (Web Ex) Rev. I

Why launch two new Why launch two new wholesale kits?wholesale kits?Why launch two new Why launch two new wholesale kits?wholesale kits?

Reason for the kits:

Main reason: Motorola XC68HC…P18 Microprocessor is no

longer available on the 50M51-242, 50M61’s, 50V51-XXX & 50V61-XXX.

We needed to replace the 50M61-843 in wholesale with a new control, so we developed a better control, 50M51-843 (module) with more features than the 50M61-843.

6 Emerson Confidential

Why a new kit?

Page 7: 21 V51 U 843 & 21 M51 U 843 Presentation (Web Ex) Rev. I

Differences between the Differences between the Old (50M61-843) & New Models.Old (50M61-843) & New Models.

Differences between the Differences between the Old (50M61-843) & New Models.Old (50M61-843) & New Models.

7 Emerson Confidential

Features

FEATURES 50M61-843 21M51U-843   21V51U-843 21M51U-843

Fault Recall No Yes  Variable Speed

Blower 3-Speed PSC

Blower

Error Code 10 21  DeHum

(24V)Terminal Twin

(24V)Terminal

Ignitor 80V 120V   CFM - LED -

LED Red Tri-Colored  

Auto 2nd Stage

No Yes 

Page 8: 21 V51 U 843 & 21 M51 U 843 Presentation (Web Ex) Rev. I

CompetitionCompetitionCompetitionCompetition

WR is the first to offer a Universal Two Stage Control for the After Market

Carrier supply’s replacement for their own furnace types

Honeywell - Doesn’t offer a Universal Control

8 Emerson Confidential

Universal Control Kit

WR (US) Carrier Honeywell

Universal 2 Stage 3 Speed (PSC)

Universal 2 Stage

Variable Speed Blower (ECM)

Page 9: 21 V51 U 843 & 21 M51 U 843 Presentation (Web Ex) Rev. I

21M Replacement Sku’s & % Usage21M Replacement Sku’s & % Usage21M Replacement Sku’s & % Usage21M Replacement Sku’s & % Usage

9 Emerson Confidential

Page 10: 21 V51 U 843 & 21 M51 U 843 Presentation (Web Ex) Rev. I

21V Replacement Sku’s & % Usage21V Replacement Sku’s & % Usage21V Replacement Sku’s & % Usage21V Replacement Sku’s & % Usage

10 Emerson Confidential

Page 11: 21 V51 U 843 & 21 M51 U 843 Presentation (Web Ex) Rev. I

Universal:

1.) Cross Reference Chart: Included Included

Listing – The Module’s no’s

and Furnace Models.

2.) Application Usages (WR only): 40 Total 17 Total

Replacing 120V Ign. 15 5

Replacing 80V Ign. 25 12

(Always Replace 80V Ign.)

11

Things WR DoesThings WR Does Things WR DoesThings WR Does 21V51U-843 / 21M51U-843

Universal

Page 12: 21 V51 U 843 & 21 M51 U 843 Presentation (Web Ex) Rev. I

21M51U-843 - Twinning21M51U-843 - Twinning21M51U-843 - Twinning21M51U-843 - Twinning

50M51-843 Module is equipped with a single wire (14-22 AWG.) twinning interface and this is done by connecting to each TWIN terminal screw

12 Emerson Confidential

Features

Twining Example: Two Furnaces using the same duct work.

50M51-843: Twinning Screw.

Page 13: 21 V51 U 843 & 21 M51 U 843 Presentation (Web Ex) Rev. I

21M51U-843 - Dip Switch Setup21M51U-843 - Dip Switch Setup21M51U-843 - Dip Switch Setup21M51U-843 - Dip Switch Setup

13 Emerson Confidential

Easy Setup Steps

S1 – Settings for Thermostat (Single/Multi Stat) Type and Heat delay-to-fan-off

Page 14: 21 V51 U 843 & 21 M51 U 843 Presentation (Web Ex) Rev. I

21V & 21M - Common Features21V & 21M - Common Features21V & 21M - Common Features21V & 21M - Common Features

Fault Recall – Used to retrieve past error faults

LED Status – Tri-Colored

14 Emerson Confidential

Features

Push button

Green/ Amber/Red

Page 15: 21 V51 U 843 & 21 M51 U 843 Presentation (Web Ex) Rev. I

21V51U-843 - Feature21V51U-843 - Feature21V51U-843 - Feature21V51U-843 - Feature

CFM LED – The light will flash to show the blower is functioning. That’s it!

15 Emerson Confidential

Features

CFM (Green) LED

Page 16: 21 V51 U 843 & 21 M51 U 843 Presentation (Web Ex) Rev. I

21V51U-843 - Dip Switch Setup21V51U-843 - Dip Switch Setup21V51U-843 - Dip Switch Setup21V51U-843 - Dip Switch Setup

S5 – Settings for Heat Pump & De-Humidifer

16 Emerson Confidential

Easy Setup Steps

Page 17: 21 V51 U 843 & 21 M51 U 843 Presentation (Web Ex) Rev. I

S7 – Settings for Thermostat (Single/Multi Stat) Type and Second Stage Delay & Heat-Fan-Off-Delay

17 Emerson Confidential

Easy Setup Steps 21V51U-843 - Dip Switch Setup21V51U-843 - Dip Switch Setup21V51U-843 - Dip Switch Setup21V51U-843 - Dip Switch Setup

Page 18: 21 V51 U 843 & 21 M51 U 843 Presentation (Web Ex) Rev. I

18 Emerson Confidential

Step 1.) OEM Application - Dip Switch Settings.

*Note: Factory Default setting is OFF - OFF

*

First Step – For Configuring the First Step – For Configuring the OEM Application - 21V51U-843OEM Application - 21V51U-843First Step – For Configuring the First Step – For Configuring the OEM Application - 21V51U-843OEM Application - 21V51U-843

Easy Setup Steps

S2-3 for future use

Page 19: 21 V51 U 843 & 21 M51 U 843 Presentation (Web Ex) Rev. I

19 Emerson Confidential

*Note: OEM Furnace Manual – is another source for proper settings.

For Amana/Goodman/Trane/Lennox/Thermo Pride Setting up OEM Motor Configurations.

*Match the dip switch settings from old to new.

Second Step – For Configuring Second Step – For Configuring the CFM Blower Settings - 21V51U-843the CFM Blower Settings - 21V51U-843Second Step – For Configuring Second Step – For Configuring the CFM Blower Settings - 21V51U-843the CFM Blower Settings - 21V51U-843

Easy Setup Steps

(New Board)

(Old Board)

Example

Page 20: 21 V51 U 843 & 21 M51 U 843 Presentation (Web Ex) Rev. I

20 Emerson Confidential

York – Shunt Jumpers

Shipped - Default Settings

Second Step – For Configuring the Second Step – For Configuring the CFM Blower Settings - 21V51U-843 CFM Blower Settings - 21V51U-843 Second Step – For Configuring the Second Step – For Configuring the CFM Blower Settings - 21V51U-843 CFM Blower Settings - 21V51U-843

Easy Setup Steps

New Board (50V51-843)

York Board (50V51-243)

Shipped - Default Settings

Page 21: 21 V51 U 843 & 21 M51 U 843 Presentation (Web Ex) Rev. I

21 Emerson Confidential

York – Shunt Jumpers

Another Example - For Configuring the Another Example - For Configuring the CFM Blower Settings - 21V51U-843 CFM Blower Settings - 21V51U-843 Another Example - For Configuring the Another Example - For Configuring the CFM Blower Settings - 21V51U-843 CFM Blower Settings - 21V51U-843

Easy Setup Steps

New Board (50V51-843)

York Board (50V51-243)

Match the Dip Switch Settings.

Example

Page 22: 21 V51 U 843 & 21 M51 U 843 Presentation (Web Ex) Rev. I

Supporting Launching DocumentsSupporting Launching DocumentsSupporting Launching DocumentsSupporting Launching Documents

22 Emerson Confidential

Paste Spec Sheets

Product Announcements – Coming Soon

Spec. Sheets - Now Available

Page 23: 21 V51 U 843 & 21 M51 U 843 Presentation (Web Ex) Rev. I

1.) 21M51U-843 & 21V51U-843 are Complete Universal Kits:

- These kits will replace our current controls – Listed in the cross- reference chart.

2.) How the Two Stage Kits compare to each other:

Main Difference: 21V51U-843 VS 21M51U-843

- Blower Motor: Variable Speed VS 3 Speeds

3.) 50M61-843: - Is no longer available.

4.) 21V51U-843: Two Steps on Setup:

1.) OEM Application – Set the dip switch to the OEM.

2.) CFM Blower Dip Switch – Match the existing controls settings to the new control.

23 Emerson Confidential

4 Take-Aways4 Take-Aways4 Take-Aways4 Take-Aways