2
208V 3-Phase Input L21-30P Plug 208V Single- Phase Output 36 Outlets 8.6kW Load Capacity Multimode Load Meter Network Interface 0U Rackmount Toolless Mounting Buttons 208V 50/60Hz 208V 50/60Hz C19 C13 8.6kW 0U Specifications Models PDU3VN3L2130, PDU3VN10L2130 Voltage 208V (3-Phase Input/Single-Phase Output) Frequency 50/60Hz Load Capacity 8.6kW Input Plug L21-30P Input Cord Length PDU3VN3L2130: 3 ft., PDU3VN10L2130: 10 ft. Outlets 36 (30 C13 / 6 C19) Primary Mounting Option 0U (Vertical) Rackmount Unit Weight & Dimensions PDU3VN3L2130: 10.5 lbs / 70 x 2.19 x 3.26 in. PDU3VN10L2130: 13.2 lbs / 70 x 2.19 x 3.26 in. See next page for detailed unit measurements. Certifications Tested to UL 60950-1 (US & Canada), NOM (Mexico), FCC Class A Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice. • Distributes power to 36 outlets (10 C13 & 2 C19 per phase) • Remote monitoring and control via SNMP, Web or Telnet • Displays load for any output phase in real time • Perfect for rackmount server, network and telecom applications SEE NEXT PAGE FOR DETAILED UNIT MEASUREMENTS A Digital Load Meter B C13 and C19 Outlets C 20A 2-Pole Hydraulic Magnetic Circuit Breakers D Removable Cord Retention Brackets E Removable Mounting Brackets F Toolless Mounting Buttons with Removable 90° Rotation Brackets G PDU3VN3L2130: 3-ft. Input Power Cord PDU3VN10L2130: 10-ft. Input Power Cord H L21-30P Twist-Lock Input Plug I Durable Metal Case J Network Interface K RJ45 Ethernet Jack L Manual Configuration Port M Environmental Monitoring Port N Network Interface Reset Button O Modem Port (For Future Use) 1111 W. 35th Street Chicago, IL 60609 USA 773.869.1234 www.tripplite.com 20 MODELS: PDU3VN3L2130, PDU3VN10L2130 3-Phase Monitored Rackmount PDU I G H D D B C AC Input Connection: Insert L21-30P twist-lock plug into compatible L21-30R utility, generator or UPS outlet. Also Includes: Cable Ties, Owner’s Manual, PowerAlert Software CD-ROM Multimode Load Meter: Display the load for any output phase, display the IP address or rotate the display 180°. Note: Installed 17.67 mm toolless mounting buttons can be replaced with included 14.17 mm buttons for additional compatibility. Network Interface: Connect to Ethernet for remote monitoring via SNMP, Web or Telnet. Add optional ENVIROSENSE accessory for temperature/humidity monitoring and dry contact interface. K L O M N A A H J 90° Bracket Standard D F E Note: PDU3VN3L2130: 3 ft., PDU3VN10L2130: 10 ft. J

3-Phase Monitored Rackmount PDU 30A · 2018-04-05 · nput Power CordI Owner’s Manual, PowerAlert . PDU3VN10L2130: 10-ft. nput Power CordI. H. wist-Lock L21-30P T . nput PlugI

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 3-Phase Monitored Rackmount PDU 30A · 2018-04-05 · nput Power CordI Owner’s Manual, PowerAlert . PDU3VN10L2130: 10-ft. nput Power CordI. H. wist-Lock L21-30P T . nput PlugI

208V 3-Phase Input

L21-30P Plug 208V Single-Phase Output

36 Outlets 8.6kW Load Capacity

Multimode Load Meter

Network Interface

0U Rackmount

Toolless Mounting

Buttons

208V50/60Hz C19

C13

30A

20A

15A

8.6kW

0U

C20

5-15/20R

100-125V50/60Hz

208V50/60Hz

20

208V50/60Hz C19

C13

30A

20A

15A

8.6kW

0U

C20

5-15/20R

100-125V50/60Hz

208V50/60Hz

20

208V50/60Hz C19

C13

30A

20A

15A

8.6kW

0U

C20

5-15/20R

100-125V50/60Hz

208V50/60Hz

20

208V50/60Hz C19

C13

30A

20A

15A

8.6kW

0U

C20

5-15/20R

100-125V50/60Hz

208V50/60Hz

20

208V50/60Hz C19

C13

30A

20A

15A

8.6kW

0U

C20

5-15/20R

100-125V50/60Hz

208V50/60Hz

20

208V50/60Hz C19

C13

30A

20A

15A

8.6kW

0U

C20

5-15/20R

100-125V50/60Hz

208V50/60Hz

20

208V50/60Hz C19

C13

30A

20A

15A

8.6kW

0U

C20

5-15/20R

100-125V50/60Hz

208V50/60Hz

20

208V50/60Hz C19

C13

30A

20A

15A

8.6kW

0U

C20

5-15/20R

100-125V50/60Hz

208V50/60Hz

20

SpecificationsModels PDU3VN3L2130, PDU3VN10L2130Voltage 208V (3-Phase Input/Single-Phase Output)Frequency 50/60HzLoad Capacity 8.6kWInput Plug L21-30PInput Cord Length PDU3VN3L2130: 3 ft., PDU3VN10L2130: 10 ft.Outlets 36 (30 C13 / 6 C19)Primary Mounting Option 0U (Vertical) RackmountUnit Weight & Dimensions PDU3VN3L2130: 10.5 lbs / 70 x 2.19 x 3.26 in. PDU3VN10L2130: 13.2 lbs / 70 x 2.19 x 3.26 in. See next page for detailed unit measurements.Certifications Tested to UL 60950-1 (US & Canada), NOM (Mexico), FCC Class ATripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.

• Distributespowerto36outlets (10 C13 & 2 C19 per phase)• RemotemonitoringandcontrolviaSNMP,WeborTelnet• Displaysloadforanyoutputphaseinrealtime• Perfectforrackmountserver,networkandtelecom applications

SEE NEXT PAGE FOR DETAILED UNIT MEASUREMENTS

A Digital Load Meter

B C13 and C19 Outlets

C 20A 2-Pole Hydraulic Magnetic Circuit Breakers

D Removable Cord Retention Brackets

E Removable Mounting Brackets

F Toolless Mounting Buttons with Removable 90° Rotation Brackets

G PDU3VN3L2130: 3-ft. Input Power Cord PDU3VN10L2130: 10-ft. Input Power Cord

H L21-30P Twist-Lock Input Plug

I Durable Metal Case

J Network Interface

K RJ45 Ethernet Jack

L Manual Configuration Port

M Environmental Monitoring Port

N Network Interface Reset Button

O Modem Port (For Future Use)

1111 W. 35th Street Chicago, IL 60609 USA

773.869.1234 www.tripplite.com

208V50/60Hz C19

C13

30A

20A

15A

8.6kW

0U

C20

5-15/20R

100-125V50/60Hz

208V50/60Hz

20

208V50/60Hz C19

C13

30A

20A

15A

8.6kW

0U

C20

5-15/20R

100-125V50/60Hz

208V50/60Hz

20

MODELS:

PDU3VN3L2130, PDU3VN10L21303-Phase Monitored Rackmount PDU

I

G

H

D

DB

C

AC Input Connection: Insert L21-30P twist-lock plug into compatible L21-30R utility,

generator or UPS outlet.

Also Includes: Cable Ties, Owner’s Manual, PowerAlert

Software CD-ROM

Multimode Load Meter: Display the load for any output phase, display the IP address or rotate

the display 180°.

Note: Installed 17.67 mm toolless mounting buttons

can be replaced with included 14.17 mm buttons for

additional compatibility.Network Interface: Connect to Ethernet for remote monitoring via SNMP, Web or Telnet. Add optional ENVIROSENSE accessory for temperature/humidity

monitoring and dry contact interface.

K

LO

M

N

A

A

H

J

90° Bracket Standard

D

F

E

Note: PDU3VN3L2130: 3 ft., PDU3VN10L2130: 10 ft.

J

Page 2: 3-Phase Monitored Rackmount PDU 30A · 2018-04-05 · nput Power CordI Owner’s Manual, PowerAlert . PDU3VN10L2130: 10-ft. nput Power CordI. H. wist-Lock L21-30P T . nput PlugI

Dimensions: [mm] INCHES Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.

Copyright © 2010 Tripp Lite. 200909176T

MODELS:

PDU3VN3L2130, PDU3VN10L2130

1111 W. 35th Street Chicago, IL 60609 USA

773.869.1234 www.tripplite.com

REAR VIEWFRONT VIEW SIDE VIEW

Note: Installed 17.67 mm toolless mounting buttons can be replaced

with included 14.17 mm buttons

for additional compatibility.

L21-30P

C13

OUT

LET

C19

OUT

LET

[55.

5]2.

19

[36.

88]

1.45

[320

.11]

12.6

0

[177

6.44

]69

.93

[177

8.98

]70

.04

B

D

E

81.6

03.

21

REM

OV

ABL

E M

OUN

TING

BRA

CKE

TC

ORD

RET

ENTIO

N

BRA

CKE

T

REM

OV

ABL

E

TOO

LLES

SM

OUN

TING

BU

TTO

N

A13

4.01

5.28

C

REMOVABLEMOUNTING

BRACKET

TOOLLESSMOUNTING

BUTTON

TOOLLESSMOUNTING

BUTTON

DETAIL C

REMOVABLE90° ROTATION BRACKET

DETAIL A

5.28

134.

01

DETAIL B

.69

17.6

7DETAIL D

.28

7.10

DETAIL E

[309

.78]

12.2

0

[304

8]12

0[9

14.4

]36

[82.25]3.24

[17.47].69

[23.

60]

.93

[31.

75]

1.25 [3

57.1

9]14

.06

[234

]9.

21

[12.

31.8

5]48

.50

[155

3.33

]61

.15

[293

.24]

11.5

4[2

33.6

8]9.

20[2

33.6

8]9.

20[2

33.6

8]9.

20

[91.

32]

3.60

[87.

88]

3.46

[286

.32]

11.2

7

[16.

64]

.65

[121

2.80

]47

.74

[128

4.16

]50

.56

REM

OV

ABL

E 90

°RO

TATIO

N B

RAC

KET

[58.

99]

2.32

[43]

1.69

[57]2.24

[17.67]0.69

[42]1.65

[22].86