31
SUSPENSION (BY OTHER) 15 16 " HEAVY DUTY T-GRID (BY OTHER) T&G GRID CLIPS .75" T&G GRID CLIP FOR 15 16 " HD T-GRID ONLY T&G DIRECT ATTACH CLIP LAST REVISED: DRAWN BY: SCALE: AS NOTED DO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS REPRESENT ASI' UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2020 123 Columbia Court North, Chaska, Minnesota 55318 P. 800.527.6253 BH 7/6/2020 AUDITION T&G CEILING SYSTEM - SECTION & CLIP OPTIONS SHEET NUMBER 1 1 TYPICAL AUDITION PLANK SECTION DETAIL 6" = 1'-0" 2 T&G GRID CLIP 1' = 1'-0" 3 T&G DIRECT ATTACH CLIP 1' = 1'-0"

31 AUDITION T&G SYSTEM - VAULTED CEILING …...FIELD CUT TO ALLOW FOR 12" MIN REVEAL FOR EXPANSION AND CONTRACTION T&G GRID CLIP SUSPENSION (BY OTHER) 15 16" HEAVY DUTY T-GRID (BY

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 31 AUDITION T&G SYSTEM - VAULTED CEILING …...FIELD CUT TO ALLOW FOR 12" MIN REVEAL FOR EXPANSION AND CONTRACTION T&G GRID CLIP SUSPENSION (BY OTHER) 15 16" HEAVY DUTY T-GRID (BY

SUSPENSION (BY OTHER)

1516" HEAVY DUTY

T-GRID (BY OTHER)

T&G GRID CLIPS

.75"

T&G GRID CLIP FOR15

16" HD T-GRID ONLY

T&G DIRECT ATTACH CLIP

LAST REVISED: DRAWN BY:SCALE: AS NOTEDDO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS REPRESENT ASI'UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2020123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BH7/6/2020

AUDITION T&G CEILING SYSTEM -SECTION & CLIP OPTIONS

SHEET NUMBER

1

1 TYPICAL AUDITION PLANK SECTION DETAIL6" = 1'-0"

2 T&G GRID CLIP1' = 1'-0" 3 T&G DIRECT ATTACH CLIP

1' = 1'-0"

Page 2: 31 AUDITION T&G SYSTEM - VAULTED CEILING …...FIELD CUT TO ALLOW FOR 12" MIN REVEAL FOR EXPANSION AND CONTRACTION T&G GRID CLIP SUSPENSION (BY OTHER) 15 16" HEAVY DUTY T-GRID (BY

TONGUE SIDE GROOVE SIDE

PERFORATIONS (DO NOTGO THROUGH TO FRONTSIDE OF PANEL)PLANK FACE

TONGUE SIDE

GROOVE SIDE

PLANK FACE

AUDITION 32

AUDITION 16

.0512"[1.3mm]

.5787"[14.7mm]

.0512"[1.3mm]

1.2087"[30.7mm]

1.2598"[32mm]

.6299"[16mm]

AUDITION 8

.0512"[1.3mm]

.2638"[6.7mm]

.315"[8mm]

7.5472"[191.7mm]

7.5472"[191.7mm]

7.5472"[191.7mm]

LAST REVISED: DRAWN BY:SCALE: AS NOTEDDO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS REPRESENT ASI'UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2020123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BH7/6/2020

AUDITION T&G - PLANK OPTIONS AND DETAILSSHEET NUMBER

2

3 BACK OF PANEL ISOMETRIC1 1/2" = 1'-0"2 FRONT OF PANEL ISOMETRIC

1 1/2" = 1'-0"

1 PANEL OPTIONS6" = 1'-0"

Page 3: 31 AUDITION T&G SYSTEM - VAULTED CEILING …...FIELD CUT TO ALLOW FOR 12" MIN REVEAL FOR EXPANSION AND CONTRACTION T&G GRID CLIP SUSPENSION (BY OTHER) 15 16" HEAVY DUTY T-GRID (BY

START PATTERNFROM ROOM CENTER

1516" H.D. T-BAR GRID MAINS BY

OTHER (2'-0" O.C. TYP)JOINTS TO LAND ON FRAMING

START PATTERNFROM ROOM CENTER

1516" H.D. T-BAR GRID MAINS BY

OTHER (2'-0" O.C. TYP)JOINTS TO LAND ON FRAMING

LAST REVISED: DRAWN BY:SCALE: AS NOTEDDO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS REPRESENT ASI'UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2020123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BH7/6/2020

AUDITION T&G CEILING SYSTEM -FRAMING

SHEET NUMBER

3

1 TYPICAL PATTERN RCP (OPTION 1 - CENTERED ON PLANK)1/2" = 1'-0"

2 TYPICAL PATTERN RCP (OPTION 2 - CENTERED ON REVEAL)1/2" = 1'-0"

Page 4: 31 AUDITION T&G SYSTEM - VAULTED CEILING …...FIELD CUT TO ALLOW FOR 12" MIN REVEAL FOR EXPANSION AND CONTRACTION T&G GRID CLIP SUSPENSION (BY OTHER) 15 16" HEAVY DUTY T-GRID (BY

1516" HEAVY DUTY

T-GRID (BY OTHER)

TRIM (AS SPECIFIED)

AUDITION PLANK

14" X 1 1 4" DOWEL

1516" HEAVY DUTY

T-GRID (BY OTHER)

TRIM (AS SPECIFIED)

ACOUSTICAL BACKERRECOMMENDED

JOINT CENTEREDON GRID

T&G GRID CLIP

LAST REVISED: DRAWN BY:SCALE: AS NOTEDDO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS REPRESENT ASI'UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2020123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BH7/6/2020

AUDITION T&G CEILING SYSTEM -ISOMETRIC

SHEET NUMBER

4

1 ISOMETRIC VIEW - TYP.1 1/2" = 1'-0"

Page 5: 31 AUDITION T&G SYSTEM - VAULTED CEILING …...FIELD CUT TO ALLOW FOR 12" MIN REVEAL FOR EXPANSION AND CONTRACTION T&G GRID CLIP SUSPENSION (BY OTHER) 15 16" HEAVY DUTY T-GRID (BY

FIELD CUT MITERS TYP.

TRIM

AUDITION PLANK

1516" HEAVY DUTY

T-GRID (BY OTHER)(2X4 LAYOUT TYP)

T&G GRID CLIP

8" MAXIMUMCANTILEVER

4" T

YP6"

MAX

HANGER(BY OTHER)

1516" HEAVY DUTY

T-GRID (BY OTHER)

T&G GRID CLIP

1" ACOUSTICAL BACKER (2" AVAILABLE)

4" T

YP6"

MAX

SUSPENSION(BY OTHER)

1516" HEAVY DUTY

T-GRID (BY OTHER)

FIELD CUT

T&G GRID CLIP

LAST REVISED: DRAWN BY:SCALE: AS NOTEDDO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS REPRESENT ASI'UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2020123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BH7/6/2020

AUDITION T&G CEILING SYSTEM -TRIM CONDITIONS

SHEET NUMBER

5

1 TRIM @ MITERED CORNER - PLAN1 1/2" = 1'-0"

2 TRIM DETAIL 13" = 1'-0" 3 TRIM DETAIL 2

3" = 1'-0"

2

3

Page 6: 31 AUDITION T&G SYSTEM - VAULTED CEILING …...FIELD CUT TO ALLOW FOR 12" MIN REVEAL FOR EXPANSION AND CONTRACTION T&G GRID CLIP SUSPENSION (BY OTHER) 15 16" HEAVY DUTY T-GRID (BY

FIELD CUT TO ALLOW FOR 12" MINREVEAL FOR EXPANSION ANDCONTRACTION

T&G GRID CLIP

SUSPENSION (BY OTHER)

1516" HEAVY DUTY

T-GRID (BY OTHER)8" MAXIMUMCANTILEVER

FIELD CUT TO ALLOW FOR 12" MINREVEAL FOR EXPANSION ANDCONTRACTION

T&G GRID CLIP

SUSPENSION (BY OTHER)

1516" HEAVY DUTY

T-GRID (BY OTHER)

WALL ANGLE(BY OTHER)

FIELD CUT TO ALLOW FOR 12" MINREVEAL FOR EXPANSION ANDCONTRACTION

SUSPENSION (BY OTHER)

1516" HEAVY DUTY

T-GRID (BY OTHER)

T&G GRID CLIP

8" MAXIMUMCANTILEVER

SUSPENSION (BY OTHER)

WALL ANGLE(BY OTHER)

1516" HEAVY DUTY

T-GRID (BY OTHER)

FIELD CUT TO ALLOW FOR 12"MIN REVEAL FOR EXPANSIONAND CONTRACTION

T&G GRID CLIP

LAST REVISED: DRAWN BY:SCALE: AS NOTEDDO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS REPRESENT ASI'UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2020123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BH7/6/2020

AUDITION T&G CEILING SYSTEM -EDGE CONDITIONS @ WALL

SHEET NUMBER

6

1 EDGE DETAIL 13" = 1'-0" 2 EDGE DETAIL 2

3" = 1'-0"

3 EDGE DETAIL 33" = 1'-0" 4 EDGE DETAIL 4

3" = 1'-0"

Page 7: 31 AUDITION T&G SYSTEM - VAULTED CEILING …...FIELD CUT TO ALLOW FOR 12" MIN REVEAL FOR EXPANSION AND CONTRACTION T&G GRID CLIP SUSPENSION (BY OTHER) 15 16" HEAVY DUTY T-GRID (BY

WALL ANGLE(BY OTHER)

FIELD CUT TO ALLOW FOR 12" MINREVEAL FOR EXPANSION ANDCONTRACTION

T&G GRID CLIP

SUSPENSION (BY OTHER)

1516" HEAVY DUTY

T-GRID (BY OTHER)8" MAXIMUMCANTILEVER

WALL ANGLE(BY OTHER)

FIELD CUT TO ALLOW FOR 12" MINREVEAL FOR EXPANSION ANDCONTRACTION

T&G GRID CLIP

SUSPENSION (BY OTHER)

1516" HEAVY DUTY

T-GRID (BY OTHER)

LAST REVISED: DRAWN BY:SCALE: AS NOTEDDO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS REPRESENT ASI'UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2020123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BH7/6/2020

AUDITION T&G CEILING SYSTEM -EDGE CONDITIONS @ WALL

SHEET NUMBER

7

1 EDGE DETAIL 53" = 1'-0" 2 EDGE DETAIL 6

3" = 1'-0"

Page 8: 31 AUDITION T&G SYSTEM - VAULTED CEILING …...FIELD CUT TO ALLOW FOR 12" MIN REVEAL FOR EXPANSION AND CONTRACTION T&G GRID CLIP SUSPENSION (BY OTHER) 15 16" HEAVY DUTY T-GRID (BY

AUDITION PLANK

IF PENETRATION EXCEEDS2

3 BOARD WIDTH, SUPPORTBRACKETS ARE NEEDED(BY OTHER)

1516" HEAVY DUTY

T-GRID (BY OTHER)(2X4 LAYOUT TYP)

T&G GRID CLIP

INDEPENDENTLY SUPPORTEDCUSTOMER FIXTURE: FIELD CUTPENETRATION

INDEPENDENTLY SUPPORTEDCUSTOMER FIXTURE: FIELD CUTPENETRATION

IF PENETRATION EXCEEDS2

3 BOARD WIDTH, SUPPORTBRACKETS ARE NEEDED(BY OTHER)

1516" HEAVY DUTY

T-GRID (BY OTHER)(2X4 LAYOUT TYP)

T&G GRID CLIP

SUPPORT BRACKETFASTENED W/ SCREWSTO PLANKS (BY OTHER)SUSPENSION (BY OTHER)

LAST REVISED: DRAWN BY:SCALE: AS NOTEDDO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS REPRESENT ASI'UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2020123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BH7/6/2020

AUDITION T&G CEILING SYSTEM -SPRINKLER HEAD DETAIL

SHEET NUMBER

8

1 SPRINKLER HEAD DETAIL - PLAN VIEW1 1/2" = 1'-0"

2 SPRINKLER HEAD DETAIL - SECTION VIEW1 1/2" = 1'-0"

2

Page 9: 31 AUDITION T&G SYSTEM - VAULTED CEILING …...FIELD CUT TO ALLOW FOR 12" MIN REVEAL FOR EXPANSION AND CONTRACTION T&G GRID CLIP SUSPENSION (BY OTHER) 15 16" HEAVY DUTY T-GRID (BY

AUDITION PLANK

INDEPENDENTLY SUPPORTEDCUSTOMER FIXTURE: FIELD CUTPENETRATION

IF PENETRATION EXCEEDS2

3 BOARD WIDTH, SUPPORTBRACKETS ARE NEEDED(BY OTHER)

1516" HEAVY DUTY

T-GRID (BY OTHER)(2X4 LAYOUT TYP)

T&G GRID CLIP

INDEPENDENTLY SUPPORTEDCUSTOMER FIXTURE: FIELD CUTPENETRATION

IF PENETRATION EXCEEDS2

3 BOARD WIDTH, SUPPORTBRACKETS ARE NEEDED(BY OTHER)

1516" HEAVY DUTY

T-GRID (BY OTHER)(2X4 LAYOUT TYP)

T&G GRID CLIP

SUPPORT BRACKETFASTENED W/ SCREWSTO PLANKS (BY OTHER)SUSPENSION (BY OTHER)

LAST REVISED: DRAWN BY:SCALE: AS NOTEDDO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS REPRESENT ASI'UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2020123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BH7/6/2020

AUDITION T&G CEILING SYSTEM -CAN LIGHT DETAIL

SHEET NUMBER

9

1 CAN LIGHT DETAIL - PLAN VIEW1 1/2" = 1'-0"

2 CAN LIGHT DETAIL - SECTION VIEW1 1/2" = 1'-0"

2

Page 10: 31 AUDITION T&G SYSTEM - VAULTED CEILING …...FIELD CUT TO ALLOW FOR 12" MIN REVEAL FOR EXPANSION AND CONTRACTION T&G GRID CLIP SUSPENSION (BY OTHER) 15 16" HEAVY DUTY T-GRID (BY

AUDITION PLANK

IF PENETRATION EXCEEDS2

3 BOARD WIDTH, SUPPORTBRACKETS ARE NEEDED(BY OTHER)

1516" HEAVY DUTY

T-GRID (BY OTHER)(2X4 LAYOUT TYP)

T&G GRID CLIP

INDEPENDENTLY SUPPORTEDCUSTOMER FIXTURE: FIELD CUTPENETRATION

INDEPENDENTLY SUPPORTEDCUSTOMER FIXTURE: FIELD CUTPENETRATION

IF PENETRATION EXCEEDS2

3 BOARD WIDTH, SUPPORTBRACKETS ARE NEEDED(BY OTHER)

1516" HEAVY DUTY

T-GRID (BY OTHER)(2X4 LAYOUT TYP)

T&G GRID CLIP

SUPPORT BRACKETFASTENED W/ SCREWSTO PLANKS (BY OTHER)SUSPENSION (BY OTHER)

LAST REVISED: DRAWN BY:SCALE: AS NOTEDDO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS REPRESENT ASI'UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2020123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BH7/6/2020

AUDITION T&G CEILING SYSTEM -PENDANT LIGHT DETAIL

SHEET NUMBER

10

1 PENDANT LIGHT DETAIL - PLAN VIEW1 1/2" = 1'-0"

2 PENDANT LIGHT DETAIL - SECTION DETAIL1 1/2" = 1'-0"

2

Page 11: 31 AUDITION T&G SYSTEM - VAULTED CEILING …...FIELD CUT TO ALLOW FOR 12" MIN REVEAL FOR EXPANSION AND CONTRACTION T&G GRID CLIP SUSPENSION (BY OTHER) 15 16" HEAVY DUTY T-GRID (BY

AUDITION PLANK

IF PENETRATION EXCEEDS2

3 BOARD WIDTH, SUPPORTBRACKETS ARE NEEDED(BY OTHER)

1516" HEAVY DUTY

T-GRID (BY OTHER)(2X4 LAYOUT TYP)

T&G GRID CLIP

INDEPENDENTLY SUPPORTEDCUSTOMER FIXTURE: FIELD CUTPENETRATION

INDEPENDENTLY SUPPORTEDCUSTOMER FIXTURE: FIELD CUTPENETRATION

IF PENETRATION EXCEEDS2

3 BOARD WIDTH, SUPPORTBRACKETS ARE NEEDED(BY OTHER)

1516" HEAVY DUTY

T-GRID (BY OTHER)(2X4 LAYOUT TYP)

T&G GRID CLIP

SUPPORT BRACKETFASTENED W/ SCREWSTO PLANKS (BY OTHER)SUSPENSION (BY OTHER)

LAST REVISED: DRAWN BY:SCALE: AS NOTEDDO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS REPRESENT ASI'UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2020123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BH7/6/2020

AUDITION T&G CEILING SYSTEM -RECESSED SPEAKER DETAIL

SHEET NUMBER

11

1 RECESSED SPEAKER DETAIL - PLAN VIEW1 1/2" = 1'-0"

2 RECESSED SPEAKER DETAIL - SECTION VIEW1 1/2" = 1'-0"

2

Page 12: 31 AUDITION T&G SYSTEM - VAULTED CEILING …...FIELD CUT TO ALLOW FOR 12" MIN REVEAL FOR EXPANSION AND CONTRACTION T&G GRID CLIP SUSPENSION (BY OTHER) 15 16" HEAVY DUTY T-GRID (BY

AUDITION PLANK

BRACKETS REQ'D (BY OTHER)

T&G GRID CLIP

1516" HEAVY DUTY

T-GRID (BY OTHER)(2X4 LAYOUT TYP)

INDEPENDENTLY SUPPORTEDCUSTOMER FIXTURE: FIELD CUTPENETRATION

INDEPENDENTLY SUPPORTEDCUSTOMER FIXTURE: FIELD CUTPENETRATION

1516" HEAVY DUTY

T-GRID (BY OTHER)(2X4 LAYOUT TYP)

TRIM PLATE (BY OTHER)T&G GRID CLIP

SUSPENSION (BY OTHER)

LAST REVISED: DRAWN BY:SCALE: AS NOTEDDO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS REPRESENT ASI'UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2020123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BH7/6/2020

AUDITION T&G CEILING SYSTEM -LINEAR LIGHT DETAIL

SHEET NUMBER

12

1 LINEAR LIGHT DETAIL - PLAN VIEW1" = 1'-0"

2 LINEAR LIGHT DETAIL - SECTION VIEW1 1/2" = 1'-0"

2

Page 13: 31 AUDITION T&G SYSTEM - VAULTED CEILING …...FIELD CUT TO ALLOW FOR 12" MIN REVEAL FOR EXPANSION AND CONTRACTION T&G GRID CLIP SUSPENSION (BY OTHER) 15 16" HEAVY DUTY T-GRID (BY

AUDITION PLANK

IF PENETRATION EXCEEDS2

3 BOARD WIDTH, SUPPORTBRACKETS ARE NEEDED(BY OTHER)

1516" HEAVY DUTY

T-GRID (BY OTHER)(2X4 LAYOUT TYP)

T&G GRID CLIP

INDEPENDENTLY SUPPORTEDCUSTOMER FIXTURE: FIELD CUTPENETRATION

INDEPENDENTLY SUPPORTEDCUSTOMER FIXTURE: FIELD CUTPENETRATION

IF PENETRATION EXCEEDS2

3 BOARD WIDTH, SUPPORTBRACKETS ARE NEEDED(BY OTHER)

1516" HEAVY DUTY

T-GRID (BY OTHER)(2X4 LAYOUT TYP)

T&G GRID CLIP

SUPPORT BRACKETFASTENED W/ SCREWSTO PLANKS (BY OTHER)SUSPENSION (BY OTHER)

LAST REVISED: DRAWN BY:SCALE: AS NOTEDDO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS REPRESENT ASI'UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2020123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BH7/6/2020

AUDITION T&G CEILING SYSTEM -DIFFUSER DETAIL

SHEET NUMBER

13

1 LINEAR DIFFUSER DETAIL - PLAN VIEW1 1/2" = 1'-0"

2 LINEAR DIFFUSER DETAIL - SECTION VIEW1 1/2" = 1'-0"

2

Page 14: 31 AUDITION T&G SYSTEM - VAULTED CEILING …...FIELD CUT TO ALLOW FOR 12" MIN REVEAL FOR EXPANSION AND CONTRACTION T&G GRID CLIP SUSPENSION (BY OTHER) 15 16" HEAVY DUTY T-GRID (BY

SCRAP 1516" HD T-GRID BACKER

RAILS TO BE BACK SCREWED INFIELD

ACCESS PANEL SEAM (FIELDCUT)

ACCESS PANEL

T&G GRID CLIP

RIP TONGUE IN FIELD

RIP TONGUE IN FIELD

FIXED PLANK (BACKSCREWED TO CEILING GRID)

T&G GRID CLIPSCREWED TO BACKER

BACKER RAILS (BY OTHER)

FIXED PLANK (BACKSCREWED TO CEILING GRID)

RIP TONGUE IN FIELDRIP TONGUE IN FIELD

LAST REVISED: DRAWN BY:SCALE: AS NOTEDDO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS REPRESENT ASI'UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2020123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BH7/6/2020

AUDITION T&G CEILING SYSTEM -ACCESS PANEL

SHEET NUMBER

14

1 ACCESS PANEL DETAIL1 1/2" = 1'-0"

2 ACCESS PANEL SECTION3" = 1'-0"

2

Page 15: 31 AUDITION T&G SYSTEM - VAULTED CEILING …...FIELD CUT TO ALLOW FOR 12" MIN REVEAL FOR EXPANSION AND CONTRACTION T&G GRID CLIP SUSPENSION (BY OTHER) 15 16" HEAVY DUTY T-GRID (BY

TYP. WALL ASSEMBLY (BY OTHER)

T&G DIRECT ATTACH CLIPSCREWED TO FRAMING

FURRING (BY OTHER): ACOUSTICALBACKER RECOMMENDED BETWEENFURRING (1" AND 2" AVAILABLE)

T&G DIRECT ATTACH CLIP

LAST REVISED: DRAWN BY:SCALE: AS NOTEDDO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS REPRESENT ASI'UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2020123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BH7/6/2020

AUDITION T&G WALL SYSTEM -HORIZONTAL WALL SECTION

SHEET NUMBER

15

1 LINEAR HORIZONTAL WALL SECTION3" = 1'-0" 2 DIRECT ATTACHMENT CLIP

1' = 1'-0"

Page 16: 31 AUDITION T&G SYSTEM - VAULTED CEILING …...FIELD CUT TO ALLOW FOR 12" MIN REVEAL FOR EXPANSION AND CONTRACTION T&G GRID CLIP SUSPENSION (BY OTHER) 15 16" HEAVY DUTY T-GRID (BY

16"O.C. TYP

DRYWALL OVER FRAMING (BY OTHER)

FRAMING (BY OTHER) JOINTS TO LAND ON FRAMING

24"O.C. TYP JOINTS TO LAND ON FRAMING

DRYWALL OVER FRAMING (BY OTHER)

FRAMING (BY OTHER)

LAST REVISED: DRAWN BY:SCALE: AS NOTEDDO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS REPRESENT ASI'UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2020123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BH7/6/2020

AUDITION T&G WALL SYSTEM -HORIZONTAL WALL PATTERN

SHEET NUMBER

16

1 TYPICAL HORIZONTAL STAGGERED WALL PATTERN - 16 INCH SPACING1/2" = 1'-0"

2 TYPICAL HORIZONTAL STAGGERED WALL PATTERN - 24 INCH SPACING1/2" = 1'-0"

Page 17: 31 AUDITION T&G SYSTEM - VAULTED CEILING …...FIELD CUT TO ALLOW FOR 12" MIN REVEAL FOR EXPANSION AND CONTRACTION T&G GRID CLIP SUSPENSION (BY OTHER) 15 16" HEAVY DUTY T-GRID (BY

ALL JOINTSCENTEREDON FURRING

TYP. WALL ASSEMBLY (BY OTHER)

16 GA. FINISHNAIL (BY OTHER)

T&G DIRECT ATTACHMENTCLIP SCREWED TO FRAMINGIN FIELD

TRIM TO COINCIDE W/ FURRINGTHICKNESS FASTENED W/ FINISHNAIL (OPTIONAL)

FURRING (BY OTHER) FASTENED TOSTRUCTURE IN FIELD: ACOUSTICALBACKER RECOMMENDED BETWEENFURRING

LAST REVISED: DRAWN BY:SCALE: AS NOTEDDO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS REPRESENT ASI'UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2020123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BH7/6/2020

AUDITION T&G WALL SYSTEM -HORIZONTAL ISOMETRIC

SHEET NUMBER

17

1 HORIZONTAL WALL SYSTEM ISOMETRIC1 1/2" = 1'-0"

Page 18: 31 AUDITION T&G SYSTEM - VAULTED CEILING …...FIELD CUT TO ALLOW FOR 12" MIN REVEAL FOR EXPANSION AND CONTRACTION T&G GRID CLIP SUSPENSION (BY OTHER) 15 16" HEAVY DUTY T-GRID (BY

TYP. WALL SYSTEM(BY OTHER)

34" TRIM FASTENED W/ FINISH

NAIL AND PUTTIED IN FIELDT&G DIRECT ATTACH CLIPSCREWED TO FRAMING

FURRING (BY OTHER): ACOUSTICALBACKER RECOMMENDED BETWEENFURRING (1" AND 2" AVAILABLE)

TYP. WALL SYSTEM(BY OTHER)

34" TRIM FASTENED W/ FINISH

NAIL AND PUTTIED IN FIELDT&G DIRECT ATTACH CLIPSCREWED TO FRAMING

FURRING (BY OTHER): ACOUSTICALBACKER RECOMMENDED BETWEENFURRING (1" AND 2" AVAILABLE)

PAINTED BLACK FRAMING@ REVEAL (BY OTHER)

34" TRIM FASTENED W/ FINISH

NAIL AND PUTTIED IN FIELD

PAINTED BLACK FRAMING@ REVEAL (BY OTHER)

34" TRIM FASTENED W/ FINISH

NAIL AND PUTTIED IN FIELD

LAST REVISED: DRAWN BY:SCALE: AS NOTEDDO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS REPRESENT ASI'UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2020123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BH7/6/2020

AUDITION T&G WALL SYSTEM -HORIZONTAL TRIM CONDITIONS

SHEET NUMBER

18

1 HORIZONTAL WALL PLAN @ TRIM3" = 1'-0"

2 HORIZONTAL WALL ELEVATION @ TRIM3" = 1'-0"

2

Page 19: 31 AUDITION T&G SYSTEM - VAULTED CEILING …...FIELD CUT TO ALLOW FOR 12" MIN REVEAL FOR EXPANSION AND CONTRACTION T&G GRID CLIP SUSPENSION (BY OTHER) 15 16" HEAVY DUTY T-GRID (BY

TYP. WALL SYSTEM (BY OTHER)

T&G DIRECT ATTACH CLIPSCREWED TO FRAMING

FURRING (BY OTHER): ACOUSTICALBACKER RECOMMENDED BETWEENFURRING (1" AND 2" AVAILABLE)

T&G DIRECT ATTACH CLIP

LAST REVISED: DRAWN BY:SCALE: AS NOTEDDO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS REPRESENT ASI'UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2020123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BH7/6/2020

AUDITION T&G WALL SYSTEM -VERTICAL WALL SECTION

SHEET NUMBER

19

1 LINEAR VERTICAL WALL SECTION3" = 1'-0" 2 DIRECT ATTACHMENT CLIP

1' = 1'-0"

Page 20: 31 AUDITION T&G SYSTEM - VAULTED CEILING …...FIELD CUT TO ALLOW FOR 12" MIN REVEAL FOR EXPANSION AND CONTRACTION T&G GRID CLIP SUSPENSION (BY OTHER) 15 16" HEAVY DUTY T-GRID (BY

BASE AS SCHEDULED (BY OTHER)

START PATTERNFROM ROOM CENTER

JOINTS TO LANDON FRAMING

FACE NAILED ANDPUTTIED IN FIELD @ BASE

HORIZONTAL FURRING OVERDRYWALL (BY OTHER)

DRYWALL UNDERHORIZONTAL FURRING

NOTE: START PATTERN O.C. WITHREVEAL OR PLANK - WHICHEVERLEAVES THE LARGEST POSSIBLEBOARD WIDTH @ PERIMETER

BASE AS SCHEDULED (BY OTHER)

START PATTERNFROM ROOM CENTER

JOINTS TO LANDON FRAMING

FACE NAILED ANDPUTTIED IN FIELD @ BASE

HORIZONTAL FURRING OVERDRYWALL (BY OTHER)

DRYWALL UNDERHORIZONTAL FURRING

LAST REVISED: DRAWN BY:SCALE: AS NOTEDDO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS REPRESENT ASI'UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2020123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BH7/6/2020

AUDITION T&G WALL SYSTEM -VERTICAL WALL PATTERN

SHEET NUMBER

20

1 VERTICAL WALL PATTERN 11/2" = 1'-0" 1 VERTICAL WALL PATTERN 1

1/2" = 1'-0"

Page 21: 31 AUDITION T&G SYSTEM - VAULTED CEILING …...FIELD CUT TO ALLOW FOR 12" MIN REVEAL FOR EXPANSION AND CONTRACTION T&G GRID CLIP SUSPENSION (BY OTHER) 15 16" HEAVY DUTY T-GRID (BY

ALL JOINTSCENTEREDON FRAMING

T&G DIRECT ATTACHMENT CLIPSCREWED TO FRAMING IN FIELD

TYP. WALL SYSTEM (BY OTHER)

16 GA. FINISHNAIL (BY OTHER)

HORIZONTAL FURRING OVER DRYWALL(BY OTHER): ACOUSTICAL BACKERRECOMMENDED BETWEEN FURRING

TRIM TO COINCIDE W/ FURRINGTHICKNESS FASTENED W/ FINISHNAIL (OPTIONAL)

LAST REVISED: DRAWN BY:SCALE: AS NOTEDDO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS REPRESENT ASI'UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2020123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BH7/6/2020

AUDITION T&G WALL SYSTEM -VERTICAL ISOMETRIC

SHEET NUMBER

21

1 VERTICAL WALL SYSTEM ISOMETRIC1 1/2" = 1'-0"

Page 22: 31 AUDITION T&G SYSTEM - VAULTED CEILING …...FIELD CUT TO ALLOW FOR 12" MIN REVEAL FOR EXPANSION AND CONTRACTION T&G GRID CLIP SUSPENSION (BY OTHER) 15 16" HEAVY DUTY T-GRID (BY

TYP. WALL SYSTEM(BY OTHER)

34" TRIM FASTENED W/

FINISH NAIL AND PUTTIEDIN FIELD BY OTHER

FURRING (BY OTHER): ACOUSTICALBACKER RECOMMENDED BETWEENFURRING (1" AND 2" AVAILABLE)

T&G DIRECT ATTACH CLIPSCREWED TO FRAMING

3 4" TRIM FASTENED W/FINISH NAIL AND PUTTIEDIN FIELD BY OTHER

HORIZONTAL FURRING OVERDRYWALL (BY OTHER)

LAST REVISED: DRAWN BY:SCALE: AS NOTEDDO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS REPRESENT ASI'UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2020123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BH7/6/2020

AUDITION T&G WALL SYSTEM -VERTICAL TRIM CONDITIONS

SHEET NUMBER

22

1 VERTICAL WALL PLAN @ TRIM3" = 1'-0"

2 VERTICAL WALL ELEVATION @ TRIM3" = 1'-0"

2

Page 23: 31 AUDITION T&G SYSTEM - VAULTED CEILING …...FIELD CUT TO ALLOW FOR 12" MIN REVEAL FOR EXPANSION AND CONTRACTION T&G GRID CLIP SUSPENSION (BY OTHER) 15 16" HEAVY DUTY T-GRID (BY

LIGHT SWITCH PENETRATION FIELD CUT

FRAMING (BY OTHER)

LIGHT SWITCH PENETRATION FIELD CUT

T&G DIRECT ATTACH CLIP SCREWED TO FRAMING

TYP. WALL SYSTEM (BY OTHER)

FURRING (BY OTHER): ACOUSTICALBACKER RECOMMENDED BETWEENFURRING (1" AND 2" AVAILABLE)

LAST REVISED: DRAWN BY:SCALE: AS NOTEDDO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS REPRESENT ASI'UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2020123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BH7/6/2020

AUDITION T&G WALL SYSTEM - LIGHTSWITCH DETAIL

SHEET NUMBER

23

1 LIGHT SWITCH DETAIL - ELEVATION3" = 1'-0"

2 LIGHT SWITCH DETAIL - SECTION3" = 1'-0"

2

Page 24: 31 AUDITION T&G SYSTEM - VAULTED CEILING …...FIELD CUT TO ALLOW FOR 12" MIN REVEAL FOR EXPANSION AND CONTRACTION T&G GRID CLIP SUSPENSION (BY OTHER) 15 16" HEAVY DUTY T-GRID (BY

FRAMING (BY OTHER)

OUTLET PENETRATION FIELD CUT

OUTLET PENETRATION FIELD CUT

T&G DIRECT ATTACH CLIP SCREWED TO FRAMING

TYP. WALL SYSTEM (BY OTHER)

FURRING (BY OTHER): ACOUSTICALBACKER RECOMMENDED BETWEENFURRING (1" AND 2" AVAILABLE)

LAST REVISED: DRAWN BY:SCALE: AS NOTEDDO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS REPRESENT ASI'UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2020123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BH7/6/2020

AUDITION T&G WALL SYSTEM -OUTLET DETAIL

SHEET NUMBER

24

1 OUTLET DETAIL - ELEVATION3" = 1'-0"

2 OUTLET DETAIL - SECTION3" = 1'-0"

2

Page 25: 31 AUDITION T&G SYSTEM - VAULTED CEILING …...FIELD CUT TO ALLOW FOR 12" MIN REVEAL FOR EXPANSION AND CONTRACTION T&G GRID CLIP SUSPENSION (BY OTHER) 15 16" HEAVY DUTY T-GRID (BY

BASE AS SCHEDULED (BY OTHER)

FRAMING (BY OTHER) TO MATCHACOUSTICAL BACKER THICKNESS

FACE NAIL & PUTTY IN FIELD

BASE AS SCHEDULED (BY OTHER)

FURRING (BY OTHER): ACOUSTICALBACKER RECOMMENDED BETWEENFURRING (1" AND 2" AVAILABLE)

T&G DIRECT ATTACH CLIP SCREWED TO FRAMING

FACE NAIL & PUTTY IN FIELD

LAST REVISED: DRAWN BY:SCALE: AS NOTEDDO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS REPRESENT ASI'UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2020123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BH7/6/2020

AUDITION T&G WALL SYSTEM -BASEBOARD DETAIL

SHEET NUMBER

25

1 BASEBOARD DETAIL - ELEVATION3" = 1'-0"

2 BASEBOARD DETAIL - SECTION3" = 1'-0"

2

Page 26: 31 AUDITION T&G SYSTEM - VAULTED CEILING …...FIELD CUT TO ALLOW FOR 12" MIN REVEAL FOR EXPANSION AND CONTRACTION T&G GRID CLIP SUSPENSION (BY OTHER) 15 16" HEAVY DUTY T-GRID (BY

FIELD CUT

T&G DIRECT ATTACH CLIP SCREWED TO FRAMING

FACE NAIL IN FIELD

TYPICAL WALL ASSEMBLY (BY OTHER)

FURRING (BY OTHER): ACOUSTICALBACKER RECOMMENDED BETWEENFURRING (1" AND 2" AVAILABLE)

FIELD CUT

OUTSIDE CORNER MOULDING

FACE NAIL IN FIELD

T&G DIRECT ATTACH CLIPSCREWED TO FURRING

TYPICAL WALL ASSEMBLY(BY OTHER)

FURRING (BY OTHER): ACOUSTICALBACKER RECOMMENDED BETWEENFURRING (1" AND 2" AVAILABLE)

.75"

.75"

2.02

"

2.02"

OUTSIDE CORNERMOULDING 8'LENGTHS TYPICAL

LAST REVISED: DRAWN BY:SCALE: AS NOTEDDO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS REPRESENT ASI'UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2020123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BH7/6/2020

AUDITION T&G WALL SYSTEM -WALL-TO-WALL CORNER

SHEET NUMBER

26

1 VERTICAL PLANK INSIDE CORNER PLAN3" = 1'-0"

2 VERTICAL PLANK OUTSIDE CORNER PLAN3" = 1'-0" 3 SECTION (WDOCT)

1' = 1'-0"

3

Page 27: 31 AUDITION T&G SYSTEM - VAULTED CEILING …...FIELD CUT TO ALLOW FOR 12" MIN REVEAL FOR EXPANSION AND CONTRACTION T&G GRID CLIP SUSPENSION (BY OTHER) 15 16" HEAVY DUTY T-GRID (BY

BACKSCREW IN FIELD

FIELD CUT

FACE NAIL IN FIELD

FURRING (BY OTHER): ACOUSTICALBACKER RECOMMENDED BETWEENFURRING (1" AND 2" AVAILABLE)

T&G DIRECT ATTACH CLIPSCREWED TO FRAMING

1516" HEAVY DUTY

T-GRID (BY OTHER)

SUSPENSION (BY OTHER)

T&G GRID CLIP

LAST REVISED: DRAWN BY:SCALE: AS NOTEDDO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS REPRESENT ASI'UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2020123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BH7/6/2020

AUDITION T&G SYSTEM -WALL-TO-CIELING TRANSITION

SHEET NUMBER

27

1 WALL-TO-CEILING TRANSITION3" = 1'-0"

Page 28: 31 AUDITION T&G SYSTEM - VAULTED CEILING …...FIELD CUT TO ALLOW FOR 12" MIN REVEAL FOR EXPANSION AND CONTRACTION T&G GRID CLIP SUSPENSION (BY OTHER) 15 16" HEAVY DUTY T-GRID (BY

FIELD CUT LAP JOINT

SUSPENSION (BY OTHER)15

16" HEAVY DUTYT-GRID (BY OTHER)

BACKSCREW IN FIELD

FACE NAIL IN FIELD

FURRING (BY OTHER): ACOUSTICALBACKER RECOMMENDED BETWEENFURRING (1" AND 2" AVAILABLE)

T&G DIRECT ATTACH CLIPSCREWED TO FURRING

T&G GRID CLIP

EVERY 6TH PLANK TO BEBACKSCREWED IN FIELD

FIELD CUT LAP JOINT

SUSPENSION (BY OTHER)

1516" HEAVY DUTY

T-GRID (BY OTHER)

T&G DIRECT ATTACH CLIPSCREWED TO FURRING

T&G GRID CLIP FURRING (BY OTHER): ACOUSTICALBACKER RECOMMENDED BETWEENFURRING (1" AND 2" AVAILABLE)

LAST REVISED: DRAWN BY:SCALE: AS NOTEDDO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS REPRESENT ASI'UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2020123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BH7/6/2020

AUDITION T&G SYSTEM -WALL-TO-VAULTED CEILING

SHEET NUMBER

28

1 HORIZONTAL WALL-TO-VAULTED CEILING3" = 1'-0"

2 VERTICAL WALL-TO-VAULTED CEILING3" = 1'-0"

Page 29: 31 AUDITION T&G SYSTEM - VAULTED CEILING …...FIELD CUT TO ALLOW FOR 12" MIN REVEAL FOR EXPANSION AND CONTRACTION T&G GRID CLIP SUSPENSION (BY OTHER) 15 16" HEAVY DUTY T-GRID (BY

1516" HEAVY DUTY

T-GRID (BY OTHER)

T&G GRID CLIP

EVERY 6TH PLANK TO BEBACKSCREWED IN FIELD

BACKSCREW IN FIELD

SUSPENSION (BY OTHER)

MITER IN FIELD

1516" HEAVY DUTY

T-GRID (BY OTHER)

MITER IN FIELD

SUSPENSION (BY OTHER)

T&G GRID CLIP

BACKSCREW IN FIELD

LAST REVISED: DRAWN BY:SCALE: AS NOTEDDO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS REPRESENT ASI'UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2020123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BH7/6/2020

AUDITION T&G SYSTEM - VAULTEDCEILING RETURN

SHEET NUMBER

29

1 HORIZONTAL VAULTED CEILING RETURN3" = 1'-0"

2 VERTICAL VAULTED CEILING RETURN3" = 1'-0"

Page 30: 31 AUDITION T&G SYSTEM - VAULTED CEILING …...FIELD CUT TO ALLOW FOR 12" MIN REVEAL FOR EXPANSION AND CONTRACTION T&G GRID CLIP SUSPENSION (BY OTHER) 15 16" HEAVY DUTY T-GRID (BY

SUSPENSION (BY OTHER)

1516" HEAVY DUTY

T-GRID (BY OTHER)

T&G GRID CLIP

USE T&G PLANK FORFIELD CUT TRIM

FIELD-CUT TRIM OPTIONTO BE FACE-NAILEDAND PUTTIED IN FIELD

USE T&G PLANK FORFIELD CUT TRIM

SUSPENSION (BY OTHER)

1516" HEAVY DUTY

T-GRID (BY OTHER)

FIELD-CUT TRIM OPTIONTO BE FACE-NAILEDAND PUTTIED IN FIELD

T&G GRID CLIP

LAST REVISED: DRAWN BY:SCALE: AS NOTEDDO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS REPRESENT ASI'UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2020123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BH7/6/2020

AUDITION T&G SYSTEM - VAULTEDCEILING PEAKS

SHEET NUMBER

30

1 HORIZONTAL VAULTED CEILING PEAK3" = 1'-0"

2 VERTICAL VAULTED CEILING PEAK3" = 1'-0"

Page 31: 31 AUDITION T&G SYSTEM - VAULTED CEILING …...FIELD CUT TO ALLOW FOR 12" MIN REVEAL FOR EXPANSION AND CONTRACTION T&G GRID CLIP SUSPENSION (BY OTHER) 15 16" HEAVY DUTY T-GRID (BY

SUSPENSION (BY OTHER)

1516" HEAVY DUTY

T-GRID (BY OTHER)

BACKSCREWED IN FIELD

FIELD CUT LAP JOINT

T&G GRID CLIP

FIELD CUT LAP JOINT

SUSPENSION (BY OTHER)

1516" HEAVY DUTY

T-GRID (BY OTHER)

BACKSCREWED IN FIELD

T&G GRID CLIP

LAST REVISED: DRAWN BY:SCALE: AS NOTEDDO NOT SCALE DRAWING. FIGURED DIMENSIONS ARE TO BE FOLLOWED. READ THIS DRAWING IN CONNECTION WITH GENERAL ARCHITECTURAL PLANS, STRUCTURAL PLANS, AND OTHER RELATED DRAWINGS. THESE DRAWINGS REPRESENT ASI'UNDERSTANDING AND INTERPRETATION OF THE ARCHITECTURAL DRAWINGS AND HOW ASI PRODUCTS RELATE TO THE PROJECT. COPYRIGHT ASI © 2020123 Columbia Court North, Chaska,

Minnesota 55318 P. 800.527.6253

BH7/6/2020

AUDITION T&G SYSTEM - VAULTEDCEILING PEAKS

SHEET NUMBER

31

1 HORIZONTAL VAULTED CEILING PEAK - LAP JOINT3" = 1'-0"

2 VERTICAL VAULTED CEILING PEAK - LAP JOINT3" = 1'-0"