EXIT1. Check all windows and doors are closed.2. a) Fullguard - Press 'Away' then 'Arm'.or b) Partguard - Press 'Home' then 'Arm'.3. Leave premises by entry/exit route.ENTRY1. Enter premises by entry/exit route.2. Enter your 4 digit password. If a mistake is made re-enter the correct passcode.
MAINS CLEAR 24Hr
Zone 1 Zone 2 Zone 3 Zone 4
1 2 3
0
4 5 6
7 8 9
ARM
OMIT
RESET
HOMEERAWAY
Installation & Operating Manual
PA44 Zone Wired Intruder
Alarm System
FOREWORDYour decision to purchase a Response PA4 Wired
Intruder Alarm System represents a major and sensible
step towards total protection of your premises, its
contents and its occupants.
All components are designed and manufactured to
provide a high standard of security protection and long,
reliable service.
The PA4 Alarm System is designed for ease of
installation using only conventional domestic tools.
However, it is essential that the installer reads and fully
understands the advice and procedures contained in
this manual and plans the system before proceeding
with the installation.
During installation, it is important that the procedures
described in this manual are followed in sequence.
This manual should be retained in a safe place for
future reference.
IMPORTANT
All components, with the exception of the External Siren,
are suitable for mounting in dry interior locations only.
Tools and Equipment Required:
3mm flat bladed screwdriver
No.1 Philips screwdriver
No.2 Philips screwdriver
Wire Cutters & Strippers
Drill
5 & 6mm Masonry Drill Bits
Bradawl
Hammer
Small Spirit Level
Additional Requirements:
Terminal Strip or Insulating Tape
2 x 9 Volt PP3 Alkaline Back-up Batteries
LOCAL AUTHORITY REGULATIONSDepending on your location within the country, you
may be required by law to notify the Local Authorities
and Police of your new alarm installation.
Local Authority requirements differ from area to area,
therefore, we recommend that you contact your Local
Borough Environmental Officer to obtain full details of
your area's requirements.
SAFETY WARNINGSBefore proceeding with the installation, please note
the following safety warnings:
1. Always follow the manufacturers advice when
using power tools, steps, ladders etc. and wear
suitable protective equipment (e.g. safety goggles)
when drilling holes and hammering home cable
clips etc.
2. Before drilling holes in walls, check for hidden
cables and pipes. The use of a cable/pipe locator
may be advisable if in any doubt.
3. When using ladders, ensure that they are
positioned on a firm stable surface at the correct
angle and suitably secured before use.
4. The use of ear defenders is advisable when working
in close proximity to the Siren due to the high sound
level produced by this device.
SYSTEM SECURITYThis system has been designed to both detect intruders
and act as a strong deterrent to would-be intruders.
Please remember that, given adequate knowledge and
time, it is possible to overcome any alarm system and
we therefore recommend that an Intruder Alarm is used
in conjunction with good physical protection such as
security windows and door locks.
The system is operated from the Control Panel using a
4 digit User Access code. Care should be taken to
ensure that your User Access code does not become
known to other people as this will compromise the
security of your system. In this event the User Access
code should be changed as soon as possible.
PA4 Wired Intruder Alarm SystemFriedland
1
CONTENTSPage No.
INTRODUCTION & OVERVIEWAlarm Control Panel 2System Operation After Power Failure 2Passive Infra Red Movement Detectors 2Magnetic Contacts 2External Siren 2
KIT CONTENTS 3
SYSTEM FEATURES
User Functions 4Arm/Disarm 4Quick Set 4Event Log 4Home and Zone Omit 4Reset 4
Installer Functions 4Programming 4Zones 424 Hour Tamper Circuit 4Siren/Anti Tamper Monitoring 4
Programmable Zone Options 4Entry/Exit 4Walk Through Zone 4
General System Programmable Options 5Entry Time 5Exit Time 5Zone Omit 5Alarm Duration 5System Reset 5User Access Code 5Installer Access Code 5Keypad Security 5
PLANNING THE INSTALLATIONLocating the Control Panel 6Detector Wiring 6Magnetic Contact Detectors 6PIR Movement Detectors 6External Siren 6Installation Example 7
INSTALLING THE CONTROL PANELTesting the Control Panel 8Wiring the Detection Zones 9
INSTALLING THE PIR MOVEMENT DETECTORSMounting the PIR Movement Detectors 10Wiring the PIR Movement Detectors 11Testing the PIR Movement Detectors at the Control Panel 11
Page No.
TYPICAL WIRING ARRANGEMENTS 12
INSTALLING THE MAGNETIC CONTACT DETECTORS
Wiring the Magnetic Contacts 14Testing Magnetic Contacts at the Control Panel 15
INSTALLING THE EXTERNAL SIRENFitting the External Siren Unit 15Wiring the Siren Unit 16
CONNECTING THE CONTROL PANELMAINS ADAPTOR AND OPTIONAL BACK-UP BATTERIES 16
PROGRAMMINGGeneral 17
INSTALLER PROGRAMMING MODE 17Changing The Installer Access Code 17Exit Delay Time Adjustment 17Entry Delay Time Adjustment 18Alarm Duration Adjustment 18Selecting ‘Home’ Feature Zones 18Selecting Walk Through Zones 18Selecting ‘Code Arming’ 19Reset System Defaults 19Lost Or Forgotten Installer Access Code 19
USER PROGRAMMING MODE 19Change The User Access Code 19
TESTING THE SYSTEM 20
OPERATING INSTRUCTIONS‘Away’ Arming All Zones 20‘Home’ Arming Pre-Selected Zones 21Arming with Occasional Zones Omitted 21Quick Arm 21Disarming the System 21Event Log 22
MAINTENANCEControl Panel and Detectors 22Back-up Batteries Batteries 22
ALARM RECORD 22
TROUBLE SHOOTING 23
EXTENDING YOUR PA4 WIRED INTRUDER ALARM SYSTEM 24
COMPONENT SPECIFICATION Back Cover
PA4 Alarm
INTR
OD
UC
TIO
N
The PA4 Alarm Package contains all components
necessary to install a complete system. The items
included in your Package are shown opposite. The
main components are as follows:-
ALARM CONTROL PANELThe Control Panel is the heart of the intruder alarm
system and contains the microprocessor and electronic
circuitry necessary to monitor the various detection
circuits (Zones) and to initiate an alarm condition in the
event of an intrusion into a protected area.
The complete system operates at 12 Volts powered
from the plug-in mains adaptor. In the event of a
mains failure, the system will operate from the
optional Back-up Batteries if these have been fitted.
The Control Panel is operated via the push buttons on the
front of the Control Panel allowing the user to ARM/
DISARM the system, Omit Zones, view the Event Log,
Test the system or Program the various system functions.
A four digit User Access Code ensures that only
authorised users can operate the system. The Control
Panel also contains a small speaker used to indicate
various conditions by means of a variety of tones.
The Control Panel incorporates a ‘Non Volatile Memory’,
(NVM) which records all program settings indefinitely
even when all power has been removed.
The Control Panel will also remember which mode it was
in when power was disconnected and revert to this
mode when power is restored, e.g. if the panel was in
Alarm Mode when the power was removed, the panel will
continue to be in Alarm Mode when power is restored.
All detectors and alarm circuits are wired from the
Control Panel and operate at 12 Volts dc.
PASSIVE INFRA RED MOVEMENTDETECTORSPassive Infra Red (PIR) detectors are designed to
detect movement in a protected area by detecting
changes in infra red radiation levels within its field of
vision. If movement is detected the PIR detector will
generating an alarm signal at the Control Panel, (if
the system is armed). PIR detectors will also detect
animals, so ensure that pets are not permitted
access to areas fitted with PIR Movement Detectors
when the system is armed.
Additional Passive Infra Red Movement Detectors
can be purchased separately, if required.
MAGNETIC CONTACT DETECTORSEach Magnetic Contact Detector comprises two parts;
a Magnetic Contact Switch and a Magnet. They are
designed to be fitted to either doors or windows with
the Magnet fixed to the moving/opening part and the
Contact Switch fixed to the door or window frame.
When the protected door or window is closed, the
Contact Switch is held closed by the magnetic field
from the Magnet. Opening the protected door or
window will remove the magnetic field and allow the
contact switch to open generating an alarm signal at
the Control Panel, (if the system is armed).
Additional Magnetic Contacts can be purchased
separately, if required.
EXTERNAL SIRENThe External Siren enclosure houses the Siren, which
when assembled, installed and wired to the Control
Panel will activate in the event of an intrusion with the
system armed. In the event of the cable to the Siren
Unit being deliberately cut an alarm will be generated
at the control panel, provided that the tamper circuit
to the Siren has been connected.
INTRODUCTION & OVERVIEW
2 PA4 Alarm
SYSTEM OPERATION AFTER POWER FAILUREIf a power failure occurs while the system is
armed and backup batteries are not fitted (or flat)
then when power is restored the system will be in
its previously armed state. If there are any PIR
detectors wired to any active zone then an alarm
will initially occur. The siren will sound for the set
alarm duration after the 3-4 minutes required for
the PIR detectors to stabilise.
This is because the PIR detectors require a period
of 3-4 minutes to stabilise before they operate
correctly and during this period they effectively
generate an alarm signal to the Control Panel.
Note: Although optional, it is strongly recommended
that backup batteries are fitted.
INTR
OD
UC
TIO
N
KIT CONTENTSThe PA4 Wired Intruder Alarm System contains the
following components.
1 x 4 Zone Control Panel
1 x Mains Adaptor
1 x External Siren
1 x External Siren Enclosure
2 x Passive Infra Red Movement Detectors
2 x Magnetic Contact Detectors
1 x 50 metres (approx) of 6 Core Cable
1 x Cable Clips and Fixings
Also included:-
Installation & Operating Manual
Window Warning Stickers
IMPORTANTPlease check all items are present BEFORE breaking
the packaging warranty seals. No claims for missing
parts will be accepted unless pack seals are in place
and intact.
EXTENDING THE PA4 ALARM SYSTEMThe following additional accessories are available to
enhance your system and provide further protection
and a higher level of security where required.
Important: The PA4 system can be expanded to
contain maximum of 7 PIR detectors.
Component Order Code
Accessory Pack
comprising the following:
2 x Passive Infra Red Movement Detectors
2 x Magnetic Contact Detectors
25 metres (approx.) of 6 Core Cable PU1
Passive Infra Red Movement Detectors
(Twin Pack) PU2
Full details of these accessories are given on page 24.
External Siren Enclosure
EXIT1. Check all windows and doors are closed.2. a) Fullguard - Press 'Away' then 'Arm'.or b) Partguard - Press 'Home' then 'Arm'.3. Leave premises by entry/exit route.ENTRY1. Enter premises by entry/exit route.2. Enter your 4 digit password. If a mistake is made re-enter the correct passcode.
MAINS CLEAR 24Hr
Zone 1 Zone 2 Zone 3 Zone 4
1 2 3
0
4 5 6
7 8 9
ARM
OMIT
RESET
HOMEERAWAY
Control Panel
2 x Magnetic ContactDetectors
Mains Adaptor
2 x PIR Movement Detectors
ExternalSiren
3PA4 Alarm
INTR
OD
UC
TIO
N
SYSTEM FEATURES
USER FUNCTIONS
ARM/DISARMThe system has an easy arming facility. To fully arm
the system simply press the button or to partially
arm the system, omitting preselected Zones; press
the button. Then press .
QUICK SETThe final arming of the system can be quicker. This is
useful for night setting when the Entry/Exit sounder
can be silenced after just a few seconds.
EVENT LOGThe Control Panel incorporates an Event Log memory
capable of storing the last 4 alarm events. The Event
Log replay will enable the user to establish which
Zones have been activated if an alarm has occurred.
HOME AND ZONE OMIT
The button is used if you are remaining on the
premises and require to arm the system while omitting
pre-selected Zones.
The button enables you to omit any Zone
combination you require on a once only or temporary
basis.
Note: The Entry/Exit Zone cannot be omitted.
RESETPressing the button clears any previously entered
information at the keypad, e.g. incorrect buttons
pressed and also clears Fault Lights, and resets the
system after an alarm.
INSTALLER FUNCTIONS
PROGRAMMINGWhen a valid installer code has been entered, access to
programming the various system options will be permitted.
ZONESThe Control Panel incorporates four detection Zones
for the connection of the system detectors. Zone 1 is
intended for exclusive connection to the detector(s)
which are located on the Entry/Exit route and will
operate the Entry/Exit timers and associated tones.
The Magnetic Contacts on the front door would
normally be connected to Zone 1.
Other Detectors can be connected to Zones 2, 3 and
4 to protect the remaining areas within the property, as
required.
24 HOUR TAMPER CIRCUITMany system components incorporate tamper
protection facilities and the associated wiring can be
monitored on a 24 hour basis to generate an alarm
condition if the equipment or wiring is interfered with.
It is recommended that all system components with
tamper facilities are monitored for tamper.
SIREN ANTI TAMPER MONITORINGWiring to the External Siren is monitored on a 24 hour
basis. In the event of the wiring to the External Siren
being damaged or deliberately cut, an alarm will be
initiated at the Control Panel.
PROGRAMMABLE ZONE OPTIONS
ENTRY/EXITZone 1 is programmed as Entry/Exit to allow the user
a preselected (adjustable) time delay to exit and enter
the premises without creating an alarm. During the
Entry/Exit procedures, a low audible warning tone will
be emitted from the Control Panel speaker. Normally
the front door of the property would be the Entry/Exit
route and would be connected to Zone 1.
WALK THROUGH ZONEZone 2 is programmed for a detector which is fitted
between the Entry/Exit door and the Control Panel,
e.g. in the downstairs hallway. When the Entry/Exit
door is opened and the entry procedure begins, the
‘Walk Through Zone’ is inhibited for the duration of the
entry time, allowing the system to be disarmed without
creating an alarm. However, if the ‘Walk Through
Zone’ is violated before the entry procedure is
initiated, a full alarm will instantly occur.
Note 1: It is advisable to change Zone 2 to an ‘Instant’
Zone if this facility is not required.
Note 2: Zone(s) selected as ‘Walk Through’, cannot
also be selected to operate on the ‘HOME’ feature.
PA4 Alarm4
OMIT
RESET
HOME
HOME
AWAY
ARM
INTR
OD
UC
TIO
N
GENERAL SYSTEM PROGRAMMABLEOPTIONS
ENTRY TIMEThis is the time programmed to allow the user to
reach the Control Panel to disarm the system before
an alarm occurs. The Entry Time may be set between
01 - 99 seconds, depending on your own requirements.
The default Entry Time is 30 seconds. If the system is
not disarmed during the Entry delay period, a full
alarm will occur when the Entry time expires.
EXIT TIMEThis is the time programmed to allow the user to
exit the premises before the system finally arms. The
default Exit Time is 30 seconds however, this time
may be set between 01 - 99 seconds, depending
on your requirements. You will need to leave all
protected areas and close protected doors/windows
before the Exit time expires or a full alarm condition
will occur.
Note: If a Zone is open when the system is armed
the Control Panel will emit a series of beeps
(different to the Entry/Exit tone) to indicate which
Zone is open, (i.e. 1 beep = Zone 1 open). It is not
possible to Arm the system until the Zone is clear or
omitted before arming.
ZONE OMITIt is possible to pre-program a section of Zones for
regular Zone omitting ie: night setting where ground
floor Zones are armed whilst first floor Zones are
omitted. Once programmed, the use of the
button will Arm the system omitting the selected Zones.
It is also possible to omit a specified Zone(s) different
to the ‘Home’ setting on a once only/temporary basis
using the button.
ALARM DURATIONThis is the time that the External Siren will sound for
following an alarm activation. The program Alarm
Duration time is 20 minutes, however this can be set
to between 01 - 20 minutes, depending on individual
requirements.
Note: Most Local Authority noise pollution requirements
set limits acceptable for alarm duration. You should
therefore check your Local Authority requirements.
SYSTEM RESET (RETURN ALL OPTIONS TOFACTORY SETTINGS)If the User/Installer Access Codes have been lost or
forgotten, or the installer is unsure of the programmed
options, it is possible to return the Control Panel
program to the factory default settings. All previously
programmed options will be cleared and the system
will require to be re-programmed to the user’s
requirements.
USER ACCESS CODETo Arm and Disarm the system and perform other
functions, the user must enter a unique 4-digit User
Access Code at the Control Panel keypad. The
default User Access Code is but
this should be changed to your own unique code
which only you and other system users know, once
installation is complete.
INSTALLER ACCESS CODETo allow programming of the system options, a unique
Installer Access Code must be entered at the Control
Panel keypad. If the user is installing the system, you
may choose your own code. However, if the system
has been installed for you by an approved installer, the
installation code may not be available. The factory
default Installer Access Code is but
this should be changed when the programming has
been completed.
KEYPAD SECURITYThe Control Panel is protected from unauthorised
disarming by means of initiating an alarm if more
than 4 incorrect attempts to enter the User Access
Code are made. In addition, if any button is pressed
when the system is armed, the Entry timer will start.
5PA4 Alarm
1 2 3 4
9 9 9 9
HOME
OMIT
INSTA
LLATIO
N
GENERALBefore attempting to install any wiring or system
components, it is recommended that a plan of the
proposed installation is prepared. This should help the
installation to be completed using the most unobtrusive
and effective methods. The following guidelines should
be followed and used in conjunction with the example
provided when preparing your own system plan.
LOCATING THE CONTROL PANELThe Control Panel should be located out of obvious
sight of potential intruders and in a safe location, but
easily accessible for system operation.
Typically, the Control Panel may be located close to the
main entry door or in a small cupboard under the stairs
(or similar) close to a mains socket. An ideal mounting
height would be the same as a household light switch
or similar. If small children are in the household, a
further consideration should be given to keeping the
Panel out of reach.
Also consider the user’s ability to hear the Entry/Exit
Tone emitted by the Control Panel effectively when
setting the system. It is preferable that the Exit Tone
can be heard from outside the property when arming
the system.
The final position of the Control Panel will depend on
the individual user requirements.
Note: If using the Home Arm feature the Control Panel
must not be located within an area protected by a PIR
Movement detector unless this detector is not
activated during Home Arm.
DETECTOR WIRINGWhere only one detector per Zone is to be connected,
the cable should be run directly to the detector.
However, if more than one detector is to be connected
to a Zone, either (a) run all cables back to the Control
Panel or (b) run one cable to the Control Panel and link
the detector contacts in ‘SERIES’ and power supplies
in ‘PARALLEL’, (refer to example installation wiring
diagrams on pages 15-16).
MAGNETIC CONTACT DETECTORSThe Magnetic Contact Detectors are suitable for
mounting in dry interior locations only.
Decide which doors and windows are to be protected by
fitting the Magnetic Contact Detectors. Normally the
front and back doors will have Magnetic Contact
Detectors fitted. Additional detectors may be fitted
where required to other more vulnerable doors or
windows, e.g. garage, patio and conservatory doors etc.
Note: It is not recommended to connect more than
four Magnetic Contacts to one Zone, as this may
cause difficulty in wiring and hinder any attempt to
remedy wiring faults efficiently.
PIR MOVEMENT DETECTORSThe PIR Detectors are suitable for mounting in dry
interior locations only.
When considering and deciding upon the mounting
position for the detector the following points should be
considered to ensure trouble free operation:
1. Ideally the detector should be positioned in a corner
of the room to be protected where the logical path
of an intruder would cut across the fan detection
pattern of the device. PIR detectors respond more
effectively to movement across the device than to
movement directly towards it.
2. Do not position the detector facing a window or
where it is exposed to direct sunlight. PIR detectors
are not suitable for use in conservatories.
3. Do not position the detector where it is exposed to
draughts.
4. Do not position the detector directly above a heat
source, (e.g. fire, radiator, boiler, etc).
5. Do not position the detector in a position where it is
subject to excessive vibration.
Note: When the system is armed, household pets
should not be allowed into an area protected by a PIR
as their movement would trigger the PIR and activate
the alarm. Alternatively a PIR protected Zone may be
'Omitted' to allow for pet movement.
EXTERNAL SIRENThe external housing should be located as high as
possible in a prominent position so that it can be
easily seen and heard. When running the cable to the
siren, the cable should pass through a hole in the
external wall and enter through the rear of the casing.
PLANNING THE INSTALLATION
PA4 Alarm6
INSTA
LLATIO
N
7PA4 Alarm
Bedroom 1
Landing Bedroom 3
Bedroom 2(Zone 4)
(omitted during night setting)
Front Door(Entry/Exit
Zone 1)
Back Door(Zone 2)
(Zone 3)
ControlPanel
Dining Room
External Siren
Living Room
Kitchen
Hallway
MagneticContactDetector
MagneticContact Detector
(Zone 3)
ControlPanel
PIR MovementDetector
PIR MovementDetector
PIR MovementDetector
EXIT1. Check all windows and doors are closed.2. a) Fullguard - Press 'Away' then 'Arm'.or b) Partguard - Press 'Home' then 'Arm'.3. Leave premises by entry/exit route.ENTRY1. Enter premises by entry/exit route.2. Enter your 4 digit password. If a mistake is made re-enter the correct passcode.
MAINS CLEAR 24Hr
Zone 1 Zone 2 Zone 3 Zone 4
1 2 3
0
4 5 6
7 8 9
ARM
OMIT
RESET
HOMEERAWAY
TYPICALGROUND
FLOOR PLAN
TYPICAL FIRST FLOOR PLAN
Surface wiring to the External Siren is not recommended
unless it is mechanically protected, e.g. in steel tubing
or equivalent. However, if surface wiring is unavoidable,
the 24 hour monitoring will activate the Control Panel
sounder if damage occurs. However, if the system is
armed at the time a full alarm will occur.
FURTHER CONSIDERATIONSIf the system is to be armed at night ie. (Zones
omitted) while the occupants remain in the household,
make sure that any detectors which are to be omitted
are wired exclusively to those Zone(s).
(Remember that a ‘Walk Through Zone’ cannot also
be selected on the ‘Home’ setting). Pay particular
attention to the most vulnerable points of entry to
your property, which are the doors and windows to
the side and rear of the property.
Plan your cable runs for ease of installation and
neatness of final appearance, allowing for concealing
cables where necessary.
INSTALLATION EXAMPLEThe following example shows typical floor plans for a two
storey domestic property incorporating the suggested
positions for the Control Panel, External Siren and
Detectors, for optimum security. Use this as a guide for
your installation in conjunction with the recommendations
for planning your intruder alarm system.
In this example, the front door is the Entry/Exit route to
the property and is connected to Zone 1.
The side door is also fitted with a Magnetic Contact
and is connected to Zone 2.
The Living Room and Dining Room are fitted with PIR
Movement Detectors detecting entry into the rooms
from any angle and are connected to Zone 3.
An additional PIR has been fitted on the upstairs
landing. The upstairs PIR Movement Detector will
detect entry into the first floor and is connected to
Zone 4 (This is the Zone which will be intentionally
omitted when the system is armed at night).
INSTA
LLATIO
N
8 PA4 Alarm
Leads and Connectors forOptional Back-up Batteries
CoverFixing
Screws
BottomCover
SpeakerLeads
Detection and AlarmWiring Terminal Blocks
CoverTamperSwitch
Keypad
NVM Reset Pinsand Link
Top KeyholeFixings
Mains AdaptorSocket
Bottom FixingHole
12
34
56
711
812
1314
1718
2122
SPEAKERD BELL B
AUX24Hr
Z1Z2
Z3Z4 1 2 3
0
4 5 6
7 8 9
ARM
OMIT
RESET
HOMEERAWAY
NVM RESET
Choose a suitable position to locate the Control Panel
as described in ‘Planning The Installation’.
Note: The Control Panel should be mounted on an
even flat surface to prevent the possibility of distortion
to the Control Panel casing.
1. There is no need to completely remove the front
cover screws, simply loosen the screws, then hinge
open and lift the cover from the top lip and place
safely to one side.
2. Hold the Control Panel in position and mark the
location of the three mounting holes on the wall. A
small spirit level placed on the casing will ensure a
perfect level.
Note the position of the cable entries that you may
require before fixing the Control Panel. The final
use of cable entries will depend on the individual
installation requirements.
3. Remove the Control Panel, drill 3 x 6mm holes and
insert the 30mm plastic wall plugs supplied. Using
the 30mm No.8 screws fix the Control Panel loosely
onto the two slotted holes at the top. The top
screws may be tightened and the remaining bottom
screw inserted when the installation is complete.
Important: Do not drill the fixing holes with the
Control Panel in position, as the resulting dust could
seriously affect the system electronics and invalidate
the guarantee.
TESTING THE CONTROL PANELThe Control Panel is factory fitted with small wire links
inserted to the Zone and 24Hr Tamper connections.
These can be removed, then replaced when testing
the Control Panel to simulate a detector switch
opening and closing.
Note: If the front cover tamper switch is not bypassed,
the Control Panel will indicate a 24 hour fault, indicated
by the 24 Hr LED and internal sounder activating. To
temporarily bypass the Control Panel Anti Tamper
Switch, connect a short piece of the alarm cable
(approx. 100 mm) between terminals 11 and 21, while
you test the Zones. Leave this wire connected
throughout the installation and whilst you connect the
detectors to the Control Panel.
Should the panel speaker sound during testing,
press followed by to silence
the tone, followed by , then continue.
INSTALLING THE CONTROL PANEL
Control Panel Internal Physical Layout
or Current User Access Code
1 2 3 4RESET
RESET
INSTA
LLATIO
N
1. Connect the plug in Mains Adaptor and switch on
the supply.
2. Press then press . The clear LED will
illuminate.
3. Remove the factory fitted link from Zone 1 terminals.
The Zone 1 LED will flash and the internal speaker will
intermittently beep once. Refit the link to extinguish
the Zone 1 LED and silence the tone.
4. Repeat this procedure for Zones 2, 3 and 4. The
Control Panel will intermittently beep twice for Zone
2, three times for Zone 3 and four times for Zone 4.
5. To test the 24 Hr Zone, first ensure the temporary
link is removed between the terminals 11 and
21. Make sure you hold down the panel tamper
switch spring, press . Remove the factory
link between terminals 11 and 12 to activate the
internal speaker. Replace the link, then enter
.
Check the 24 Hr Zone LED is illuminated, then
press . Replace the temporary link between
terminals 11 and 21.
6. To end the test sequence, press .
7. The plug in Mains Adaptor must now be
disconnected, but will be re-connected when
testing each detector as it is installed.
WIRING THE DETECTION ZONESIn order to keep wiring consistent and aid
installation/connections, it is recommended that the
following wiring code is adhered to throughout the
installation:-
Red12V +ve supply to each
PIR Movement Detector
Black0V -ve supply to each
PIR Movement Detector
Yellow Normally closed detector contact alarmBlue Zone circuit
Green24 Hr normally closed Tamper CircuitWhite
The power supply to each PIR Movement Detector
should ideally be taken direct from the Control Panel
to each detector, so that a break in the cable only
results in one detector being out of service.
However, the power supply can be taken from one
detector to the next if required, up to a maximum of
four detectors or 50 metres of cable per Zone.
All Zone and Tamper circuit wiring must be wired in a
‘SERIES’ loop from the appropriate terminals in the
Control Panel. Where ‘Series’ connections are made
terminal blocks or insulating tape must be used to
prevent bare wires touching each other.
Surface cabling should be clipped at 1m intervals using
the clips supplied.
Please refer to the appropriate circuit wiring diagrams for
typical wiring arrangements for the detectors supplied.
PA4 Alarm 9
Zones TamperCircuit
PIR DetectorPower Supply Mains Adaptor
Factory Links
Note: Remove factory wire links before connecting circuit wiring. Leave the factory wire links in place where a zone/circuit is unused.
ExternalSiren
1 2 3 4 5 6 7 118 12 13 14 17 18 21 22SPEAKER D BELL B AUX24HrZ1 Z2 Z3 Z4
Control Panel Schematic Wiring Diagram Showing Factory Links Fitted
RESET
RESET
RESET
RESET
or Current User Access Code
1 2 3 4
AWAY
INSTA
LLATIO
N
INSTALLING THE PIRMOVEMENT DETECTORSThe Passive Infra Red (PIR) Movement Detectors
supplied with this kit are suitable for mounting in dry
interior locations only.
It is recommended that the PIR Detector is mounted in
the corner of a room, approximately 2.2m above floor
level. At this height the detector will have a 12m range
with a 90º spread. If required the detector may be
mounted at an 8° angle to tilt downwards and reduce
the detection pattern range.
Before fitting the detector, observe the environmental
considerations as described in ‘Planning The Installation’.
Note: A maximum of 7 PIR Movement Detectors can
be connected to the system in total.
PIR Detection Zone Patterns
MOUNTING THE PIR MOVEMENTDETECTORS
1. Having chosen a suitable position to locate the PIR
Detector, run the required length of 6-core cable
back to the Control Panel. Do not make any
connections at this stage.
2. Slightly loosen the cover retaining screw on the PIR
and remove the cover. Carefully remove the PCB by
un-clipping the PCB retaining clip at the bottom left
of the PCB.
Important: Do not touch the PIR sensor in the
middle of the PCB as any marking may impair the
unit’s performance. If accidentally touched, clean
with a lint-free cloth.
3. The unit can be mounted for the standard 12m
range by using the top two side holes, or tilted down
by 8° using the bottom two side holes. Alternatively,
the unit can be ceiling mounted using the two holes
at the extreme top of the casing. Cable entry cut
outs are provided top and bottom, as required.
4. Carefully cut (or drill) out the required mounting
holes and cable entry. Only remove the minimum
required number of screw or cable holes, to avoid
insects entering the detector and causing false
triggering. Mount the unit using two 18mm No.4
screws and 25mm wall plugs as required, (a 5mm
hole will be required for the wall plugs).
Note: Do not over tighten or use larger headed
screws when mounting the unit, as this may distort
the casing.
PIR Movement Detector PCB Layout
2.2metres
2.2metres
8° Tilt
Distance (metres)2 4 6 8 10 12
90° angle
Distance (metres)2 4 6 8 10 12
PIR Sensor (Do Not Touch)
Anti-TamperSwitch
AlarmLED
PulseCountJumperLink
PIR
LED
N/C 24HR 1 2 3
RetainingClip
ConnectionTerminals
CoverRetaining
Screw
10 PA4 Alarm
Top Mount
VerticalMount
Angled Mount 8°
INSTA
LLATIO
N
WIRING THE PIR MOVEMENTDETECTOR(S)
1. Thread the cable through the entry on the base,
then strip back 5 mm of each core, twist the strand
ends then fold over and wire into the appropriate
terminals on the PIR Movement Detector.
The terminals on the PIR and the wires in the cable
are colour coded. The correct colour coding
should be followed throughout the entire system.
Red +ve power supply to each PIR Movement Detector.
Black 0V power supply to each PIR Movement Detector.
Yellow/Blue Detector normally closed Alarm Contact
Zone circuit.
Green/White 24 Hr normally closed Tamper circuit.
2. Carefully refit the PCB into the casing taking care
not to touch the PIR detector lens.
3. The PIR Detector incorporates an anti false alarm
feature designed to compensate for situations where
the detector may be affected by environmental
changes, (e.g. insects, hot air thermals from
radiators, etc). This feature is called ‘Pulse Count’
and may be selected for 1, 2 or 3 pulse detection.
The factory default and recommended setting is for
2 Pulse detection. However, in cases of extreme
environmental problems, or if unattributable false
alarms are experienced, it may be necessary to set
"Pulse Count" 3.
Note: The higher the ‘Pulse Count’, the more
movement will be necessary before the PIR
detector will trigger the alarm.
Pulse Count jumper link positions
4. Select the required ‘Pulse Count’. Refit the cover and
tighten the retaining screw. The PIR Movement Detector
is now ready to be connected at the Control Panel.
5. Bring the detector cable(s) though the cable entry
slot in the rear of the Control Panel and strip back
5 mm on each core.
6. Ensure that the Mains Adaptor is disconnected
from the Control Panel. Remove the appropriate
wire links, then connect the wires to the terminals
as shown in the diagrams on pages 13 - 15.
7. When the wiring has been completed, connect the
plug in Mains Adaptor. Wait 4 minutes for the
detectors to stabilise. Only the ‘Mains’ LED should
be ‘ON’ at the Control Panel.
Note: If any Zone or 24 Hr LEDs are illuminated,
refer to ‘Fault Finding’.
TESTING THE PIR MOVEMENTDETECTORS AT THE CONTROL PANEL
1. Test the PIR Movement Detectors one at a time.
Important: When testing a PIR Movement Detector,
ensure that no movement occurs in any other area
protected by PIR Movement Detector.
2. Press . The ‘Clear’ LED will illuminate.
Slowly walk across the PIR Movement Detector’s
field of view. As you are detected, the LED on the
PIR Movement detector will illuminate and the
Control Panel will emit a number of beeps
corresponding to the Zone number the detector is
connected to and the relevant Zone LED will flash.
3. When clear of the detector, the beeps will cease
and the Zone and PIR detector LEDs will extinguish.
4. Allow ten seconds for the detector to settle, then
move again to confirm that the PIR detector gives
the desired protection within the area required.
5. Repeat the above test sequence for each PIR
Movement Detector fitted.
6. When all the PIR Movement Detectors have been
tested successfully, press to return to the
Standby Mode.
7. Disconnect the Mains Adaptor before continuing
with the installation.1 Pulse 2 Pulses 3 Pulses
1 2 3 1 2 3 1 2 3
PA4 Alarm 11
SIMPLE TROUBLE SHOOTING
If the PIR Movement Detector is not operating,ie. LED not illuminating, the following simplechecks should be carried out;
1. Allow 4 minutes for the detector to stabilise thenretest.
2. If the PIR Movement Detector LED does notilluminate, check the power supply to the PIR.Check for a damaged cable or poor termination.
3. If the PIR Movement Detector false alarms, the unitmay be positioned incorrectly. Re-position the unitand adjust the ‘Pulse Count’ if necessary.
4. If the PIR Movement Detector LED is operating, butnot activating an alarm, check that the relevant Zonewire link has been removed at the Control Panel.
AWAY
RESET
INSTA
LLATIO
N
12 PA4 Alarm
PIR MOVEMENTDETECTOR
GREEN
WHITE
BLACK
3 4Z 2
1 2Z1
5 6Z3
7 8Z4
11 1224Hr
13- 14+SPEAKER
17+ -18D BELL B
21- +22AUX
CONTROL PANEL
+ -N/C 24 Hr
BLUE
YELLOW
RED
CONNECT TO REQUIRED ZONE
PIR MOVEMENTDETECTOR
GREEN
BLACK
RED
YELLOW
BLUE YELLOW
BLUE
WHITE
+ -N/C 24 Hr
RED
+ -
N/C
24 Hr
BLACK
TWIST AND INSULATE
CONNECT TO REQUIRED ZONE
GREEN
TWIST AND INSULATE
3 4Z 2
1 2Z1
5 6Z3
7 8Z4
11 1224Hr
13- 14+SPEAKER
17+ -18D BELL B
21- +22AUX
CONTROL PANEL
PIR
MO
VE
ME
NT
DE
TE
CT
ORWHITE
Wiring diagram for a Single PIR Detector on a zone
Wiring diagram for two PIR Detectors to a single zone with all cables returning to the Control Panel
TYPICAL WIRING ARRANGEMENTS
PIR MOVEMENTDETECTOR
GREEN
BLACK
RED
YELLOW
BLUE YELLOW
BLUE
WHITE
WHITE
+ -N/C 24 Hr
GREEN
3 4Z 2
1 2Z1
5 6Z3
7 8Z4
11 1224Hr
13- 14+SPEAKER
17+ -18D BELL B
21- +22AUX
CONTROL PANEL
MAGNETICCONTACTBLACK
RED
Twist (or Solder)cable cores together
and insulate
Wiring diagram for PIR Detector and Magnetic Contact Detector on different zones with all cables returning to the Control Panel
INSTA
LLATIO
N
PA4 Alarm 13
3 4Z 2
1 2Z1
5 6Z3
7 8Z4
11 1224Hr
13- 14+SPEAKER
17+ -18D BELL B
21- +22AUX
CONTROL PANEL
"24-Hour"Wiring fromDetector 1
"24-Hour"Wiring fromDetector 2
"24-Hour"Wiring fromDetector 3
"24-Hour"Wiring fromDetector 4
"24-Hour"Wiring from
Siren TamperConnections
Zone Wiring from
Detector 1
Zone Wiring from
Detector 2
Zone Wiring from
Detector 3
Zone Wiring from
Detector 4
Twist (or Solder)cable cores together
and insulate
Twist (or Solder)cable cores together
and insulate
YELLOW
YELLOW YELLOW YELLOW
BLUE BLUE BLUE
BLUE WHITE
WHITE WHITE WHITE
GREEN GREEN GREEN
GREEN
WHITE
GREEN
Series wiring of zone connections frommultiple detectors on a single zone
Series wiring of 24-hour connections from multiple detectors
PIR MOVEMENTDETECTOR
+ -N/C 24 HrBLUE YELLOW
GREENWHITE
3 4Z 2
1 2Z1
5 6Z3
7 8Z4
11 1224Hr
13- 14+SPEAKER
17+ -18D BELL B
21- +22AUX
CONTROL PANEL
REDBLACK
PIR MOVEMENTDETECTOR
+ -N/C 24 Hr
BLUE
YELLOW
WHITE
GREEN
BLACK
RED
Twist (or Solder)cable cores together
and insulate
CONNECT TO REQUIRED ZONE
Wiring diagram for multiple detectors (connected in series) on a single zone with one cable returning to the Control Panel
Wiring diagram with zones 1-4 used with allcables returning to the Control Panel MAGNETIC
CONTACT
3 4Z 2
1 2Z1
5 6Z3
7 8Z4
11 1224Hr
13- 14+SPEAKER
17+ -18D BELL B
21- +22AUX
CONTROL PANEL
+ -N/C 24 Hr
PIR MOVEMENTDETECTOR
GREEN
WHITE
BLACK
RED
BLUE
YELLOW
+ -N/C 24 Hr
PIR MOVEMENTDETECTOR
WHITE
GREEN
BLACK
RED
YELLOW
BLUE
WHITE
GREEN
YELLOW
BLUE
MAGNETICCONTACT
BLUE
YELLOW
WHITE
Twist (or Solder)cable cores together
and insulate
GREEN
INSTA
LLATIO
N
14 PA4 Alarm
Decide which doors and windows are to be protected
by Magnetic Contact Detectors, usually the front and
back doors will have Magnetic Contact Switches fitted.
Additional contacts may be fitted where required to
other vulnerable doors or windows, e.g. garage, patio
and conservatory doors etc.
Note: It is not recommended to connect more than 4
Magnetic Contacts in any one zone, as this may cause
difficulty in wiring and hinder any attempt to efficiently
remedy any wiring faults and locate the device that
initiated the alarm.
1. Having chosen a suitable position to locate the
Magnetic Contact, run the required length of 6 core
cable back to the Control Panel.
Alternatively, Magnetic Contact(s) may be wired in
series with each other and terminated appropriately.
However, working space within the Magnetic Contact
is limited and more than two or three termination's
may prove difficult.
Do not make any connections at this stage.
2. Fit the Magnet to the moving part of the window or
door (on the opening edge opposite the hinge) and
make sure that the parallel gap to where the Contact
Switch is fitted on the frame is no more than 9mm.
Typical position of contact fitted to door
WIRING THE MAGNETIC CONTACTS1. Remove one of the cable entry cut-outs on the
Contact Switch and thread the cable through the
entry into the Contact Switch housing.
2. Carefully remove the outer sheath of the cable and then
strip 5mm of insulation from the Yellow and Blue wires.
Connect the Yellow and Blue wires to the Contact
Switch terminals as shown.
3. Strip off 5 mm of the insulation from the Green and
White wires and connect together using a spare
terminal in the contact housing.
Note: If the spare contact terminals are not present in
the contact then the ends of the wires should be
securely twisted (or soldered) together and insulated.
If connecting multiple contacts the Tamper circuit
wiring should be continued in a series loop in a
similar way to the zone wiring.
The remaining wires should be trimmed back and
insulated to prevent short circuits and then tucked
away in the Contact Switch housing.
4. Fix the Contact Switch to the fixed part of the door/
window frame immediately beside and parallel to the
Magnet using two 25mm Counter-sunk fixing screws.
Ensure that the parallel gap between the Magnet and
Contact Switch positions is no greater than 9mm.
5. Bring the contact cable(s) through the cable entry
slot in the rear of the Control Panel and strip back
5mm of each core and twist the strand ends.
INSTALLING THE MAGNETIC CONTACT DETECTORS
MagnetMagnet Contact
SwitchContactSwitch
WindowMounting
DoorMounting
Max Gap9mm
(door/windowclosed)
Note: If spare terminalsare not present in theContact Switch, ends ofwires should be twisted(or soldered) togetherand insulated.
WHITE
BLUE
YELLOW
GREEN
MULTIPLE CONTACTSWired in series
SINGLE CONTACT
WHITE
BLUE
GREEN
YELLOW
INSTA
LLATIO
N
6. Ensure the Mains Adaptor is disconnected at the
Control Panel. Remove the appropriate Zone wire
link and then connect the wires to the Control Panel
terminals as shown in the diagrams on pages 13 - 15.
7. When the wiring has been completed, re-connect
the Mains Adaptor.
8. Wait 4 minutes for any PIR Movement Detectors to
stabilise, and then clear all protected area(s).
9. No Zone or 24 Hr LEDs should be ‘ON’ at the
Control Panel at this stage.
TESTING MAGNETIC CONTACTS ATTHE CONTROL PANEL1. First, ensure that all doors and windows fitted with
Magnetic Contacts are closed.
2. Press and the ‘Clear’ LED will illuminate
Note: At this stage, if any Magnetic Contacts are
open or PIR Movement Detectors are activated,
the relevant Zone LED(s) will be illuminated and
the panel will beep, The number of beeps will
indicate which Zone is open. You should ensure
that no movement occurs in areas fitted with PIR
Movement Detectors, as this may cause
confusion during the test sequence. If walking
past a PIR Movement Detector is unavoidable,
allow 10 seconds at the Control Panel for the PIR
Movement Detector to settle.
3. Open the first contact, the Control Panel will emit a
number of beeps corresponding to the Zone
number the detector is connected to and the
relevant Zone LED will flash.
Close the contact to silence the beeps and
extinguish the LED.
4. Repeat the test sequence for all Magnetic
Contacts fitted.
5. When the Magnetic Contacts have been tested
successfully, press to return to the Standby
Mode.
6. Now disconnect the Mains Adaptor before
continuing with the installation.
INSTALLING THEEXTERNAL SIRENThe External Siren should be fitted to the outside of
the building in a prominent position that is clearly
visible and at a height that is relatively inaccessible
to an intruder.
Consideration should also be given to the cable
route to the siren, with the cable preferably passing
directly through the external wall into the back of
the siren housing.
FITTING THE EXTERNAL SIREN UNIT
IMPORTANT: If ladders are required to reach the
mounting position of the Siren they should be
positioned on a firm stable surface at the correct
angle and suitably secured before use.
1. Undo the two front cover retaining screws and
remove the front cover by sliding up and away
from the backplate.
2. Fix the siren mounting bracket to the backplate
using the M3 screws, nuts and washers supplied.
3. Run the required length of cable from the Control
Panel to the External Siren position. Drill a
suitable hole through the wall so that the cable
enters through the rear of the housing without
showing on the outside of the property.
PA4 Alarm 15
BACK-PLATE
CABLEENTRYHOLE
SIRENBRACKET
SIREN
SIREN COVER
AWAY
RESET
INSTA
LLATIO
N
16 PA4 Alarm
4. Hold the backplate in position so that the hole
drilled for the cable is aligned with the cable
entry aperture and Mark the positions of the four
mounting holes. A spirit level placed on the
casing will ensure a perfect level.
5. Mount the backplate using four 35mm No.10
screws and 30mm wall plugs supplied, (a 6mm
hole will be required for the wall plugs).
WIRING THE SIREN UNIT
1. Ensure the Mains Adaptor is disconnected at the
Control Panel.
2. Strip back 5mm of insulation from the Red, Black,
Green and White wires.
3. Twist and double over the end of each wire, then
connect to the terminal blocks in the Siren and
Control Panel as shown below.
External Siren Wiring Arrangement
Note: The Green and White Tamper circuit wires
should be wired in series with the Green and White
tamper circuit wires from the detectors at the
Control Panel terminal block.
4. Refit the External Siren cover.
CONNECTING THECONTROL PANEL MAINSADAPTOR AND OPTIONALBACK-UP BATTERIES
1. Connect the Mains Adaptor to the plug in
connector in the Control Panel.
2. Plug the adaptor into a 13A socket and switch ON.
The mains LED will illuminate when the Control
Panel is powered from the mains.
(It is normal for the Mains Adaptor to appear warm
to the touch when in use).
Note: Ensure that the adaptor will not be removed
from the socket or accidently switched off, when
the system is in use.
Optional Back-up Batteries
The Control Panel has the facility to connect
Optional Back-up Batteries which will power the
system for up to 4 hours in the event of a mains
failure. Fit 2 x 9 volt PP3 Alkaline Batteries
(not supplied) to the battery connectors in the
Control Panel housing.
Note: The Back-up Batteries are NOT recharged
upon restoration of the mains supply and should be
replaced after any mains failure. The batteries
should also be changed every year to prevent
leakage and possible damage to the Control Panel.
3. The Control Panel fixing screws may now be finally
tightened. Do not over tighten the screws as this
may damage the casing.
4. Remove the temporary Anti-Tamper wire link from
terminals 11 and 21. In doing so, the internal
speaker will sound. Refit the cover and secure the
cover retaining screws, then enter
to silence the alarm.
Press to return to Standby Mode.
1124Hr 1217D BELL B 18
+–
Terminalsin Control
Panel
RED
GREEN
WHITE
BLACK
External Siren
RED
BLACK
Terminal Block
Tamper CircuitWiring to Other
Detectors
GREEN
WHITE
Twist (or Solder)cable cores together
and insulate
RESET
or Current User Access Code
1 2 3 4
Note: Although optional, it is strongly
recommended that backup batteries are fitted.
PR
OG
RA
MM
ING
PROGRAMMINGGENERALProgramming of the Control Panel options is divided
into two distinct categories, User Programming and
Installer Programming. User programming is used
when the system is fully operational, whilst Installer
Programming is only carried out when the system is
new or when subsequent changes are required.
Access to either programming mode requires a valid
User or Installer Access Code to be entered. The more
complex and infrequently required programmable
options are available in Installer Programming Mode
only. This prevents the major system functions from
being accidentally changed by a general User.
The Control Panel has most of the options factory
pre-set at the most common settings, please
consider whether you really need to change them
before re-programming.
Programmable options accessed via Installer
Programming Mode are;
a) Selecting Walk Through Zone(s)
b) Entry Time Adjustment
c) Exit Time Adjustment
d) Selecting ‘Home’ Zones (Part Setting)
e) Alarm Duration
f) Select User Access Code arming
g) Change Installer Access Code
h) Reset System Defaults
Programmable options accessed via User
Programming Mode are;
Change User Access Code
Note: The User Access code can only be changed
if the "Code Arming" feature is disabled.
INSTALLERPROGRAMMING MODEBefore changing any installer programmable options,
the Control Panel must be set to Installer Programming
Mode. This is shown by the ‘Clear’ LED flashing.
Enter the default or current Installer Acess Code.
The ‘Clear’ LED will flash to indicate that the system is
now in the Installer Programming Mode.
Once programming is complete press to return
to Standby Mode.
Note: When selecting options, the system will allow
30 seconds to make a selection. If this time is exceeded,
the Control Panel will exit the function and revert to
Installer Programming Mode and the option button will
have to be pressed again. Once a selection is made the
system will allow 10 seconds for a valid key to be
pressed. If this time is exceeded the system will return
to the top level of the installer mode and the selection
will have to be made again.
Before starting programming any feature read all the
steps first.
CHANGING THE INSTALLER ACCESS CODE
Factory default Setting: 9 9 9 9
To maintain the security of your system the Installer
Access code should be changed from the factory
default to your own unique 4-digit code. The Installer
Access code must not be the same as the User
Access code. Make a note of the new Installer Access
Code in the Alarm Record section.
To change the setting proceed as follows:
With the Control Panel already in the Installer
programming Mode (‘Clear’ LED flashing),
Press .
The 4 Zone LEDs will illuminate.
Enter the new 4-digit Installer Access code
As each digit is entered, a Zone LED will extinguish in
sequence.
Press to save the new setting or
Press to exit without saving.
The system will return to the top level Installer
Programming Mode with only the Clear LED flashing.
EXIT DELAY TIME ADJUSTMENT
Factory default Setting: 30 seconds
To change the setting proceed as follows:
With the Control Panel already in the Installer
programming Mode (‘Clear’ LED flashing),
PA4 Alarm 17
or Current Installer Access Code
9 9 9 9
RESET
ARM
RESET
1
? ? ? ?
PR
OG
RA
MM
ING
Press .
Zone 1 and 2 LEDs will illuminate.
Enter the required Exit Delay time (1-99), e.g. enter “01”
for a 1s delay, enter “99” for a 99s delay.
Press to save the new setting or
Press to exit without saving.
The system will return to the top level Installer
Programming Mode with only the Clear LED flashing.
ENTRY DELAY TIME ADJUSTMENT
Factory default Setting: 30 seconds
To change the setting proceed as follows:
With the Control Panel already in the Installer
programming Mode (‘Clear’ LED flashing),
Press .
Zone 1 and 2 LEDs will illuminate.
Enter the required Entry Delay time (1-99), e.g. enter
“01” for a 1s delay, enter “99” for a 99s delay.
Press to save the new setting or
Press to exit without saving.
The system will return to the top level Installer
Programming Mode with only the Clear LED flashing.
ALARM DURATION ADJUSTMENT
Factory default Setting: 20 minutes
To change the setting proceed as follows:
With the Control Panel already in the Installer
programming Mode (‘Clear’ LED flashing),
Press .
Zone 1 and 2 LEDs will illuminate.
Enter the required Alarm Period (1-20), e.g. enter “01” for
a 1 minute duration, enter “15” for a 15 minutes duration.
Press to save the new setting or
Press to exit without saving.
The system will return to the top level Installer
Programming Mode with only the Clear LED flashing.
SELECTING “HOME” FEATUREZONES
The button can be used to part-arm the system
omitting a selection of pre-selected Zones. This feature
is useful if you have a regular requirement to arm the
system with a permanent selection Zone(s) omitted.
For example at night when you may wish to have the
detectors on the ground floor armed, whilst the
detectors on the first floor are disarmed.
Note: The Entry/Exit Zone (Zone 1) and any zones
configured as ‘Walk Through’ cannot be omitted from
"Home" Arm.
To select the Zones to be omitted when using the
‘HOME’ feature proceed as follows:
With the Control Panel already in the Installer
programming Mode (‘Clear’ LED flashing),
Press .
The zone LEDs corresponding to the Zones currently
selected to be omitted during "Home" operation will be
illuminated.
LED ON Zone omitted during "Home" arm
LED OFF Zone active during "Home" arm.
To change the setting of a zone press the button
corresponding to the zone number. The zone will
toggle between omitted and active each time the
button is pressed. Remember, Zone 1 and any "Walk
Through" zones cannot be omitted.
Press to save the new setting or
Press to exit without saving.
The system will return to the top level Installer
Programming Mode with only the Clear LED flashing.
SELECTING WALK THROUGH ZONESZones which are located between the Entry/Exit door
and Control Panel should be configured as "Walk
Through" zones.
Zone 1 cannot be configured as a ‘Walk Through’ zone.
Zone 2 is factory set as a ‘Walk Through’ zone. It is
advisable to change Zone 2 to an ‘Instant’ Zone if this
facility is not required.
To select the Zones to be configured as "Walk Through"
zones proceed as follows:
18 PA4 Alarm
2
4
ARM
RESET
HOME
6
ARM
RESET
ARM
RESET
ARM
RESET
3
With the Control Panel already in the Installer
programming Mode (‘Clear’ LED flashing),
Press .
The zone LEDs corresponding to the Zones currently
set as "Walk Through" zones will be illuminated.
LED ON Walk Through ON
LED OFF Walk Through OFF (i.e. Instant).
To change the setting of a zone press the button
corresponding to the zone number. The zone will
toggle between "Walk Through" and "Instant "each
time the button is pressed. Remember, Zone 1 cannot
be set as "Walk Through".
Press to save the new setting or
Press to exit without saving.
The system will return to the top level Installer
Programming Mode with only the Clear LED flashing.
SELECTING ‘CODE ARMING’For convenience the Control Panel is factory set to be
able to be armed without first entering the User
Access Code. To avoid accidental arming, or if there
is a concern regarding children arming the system, it
is possible to program the Control Panel to require the
User Access Code to be entered before allowing the
system to be armed.
Important: The User Access Code should be changed
from the factory default before activating this functionality.
To activate or de-activate the code arming feature
proceed as follows:
With the Control Panel already in the Installer
programming Mode (‘Clear’ LED flashing),
Press .
Zone LED 2 will indicate the current status of the code
arming feature.
Zone 2 LED ON Code Arming Enabled
Zone 2 LED OFF Code Arming Disabled
To change the setting press to toggle code arming
ON and OFF each time the button is pressed.
Press to save the new setting or
Press to exit without saving.
RESET SYSTEM DEFAULTSIf the User Access Code has been lost or forgotten, or
the installer is unsure of the options programmed, the
system may be returned to the factory settings by the
following method;
With the Control Panel already in the Installer
programming Mode (‘Clear’ LED flashing),
Press .
Zone 1 led will flash briefly to indicate that all system
default settings have been restored.
LOST OR FORGOTTEN INSTALLER ACCESS CODE1. Switch off mains power and remove the Control
Panel front cover. The alarm will sound on tamper
if backup batteries are fitted.
2. If fitted disconnect the Control Panel Back-up
Batteries.
Important: The mains and battery power supply
must be removed before continuing.
3. Place the Jumper Link across both of the NVM
RESET pins positioned on the Control Panel PCB.
4. Wait for 30 seconds and then switch on the mains
supply adaptor.
The Clear and 24Hr LEDs will flash and after
approximately 5 s the alarm will sound on tamper,
Enter the default User Access code,
, to cancel the alarm.
5. Remove the Jumper Link (store on one Pin) replace
the front cover and reconnect the mains.
The Control Panel has been returned to factory
settings and will require programming to your
requirements.
USER PROGRAMMINGMODECHANGING THE USER ACCESS CODE
Factory default Setting: 1 2 3 4
PR
OG
RA
MM
ING
PA4 Alarm 19
1 2 3 4
7
0
8
2
ARM
RESET
ARM
RESET
Note: The User Access code can only be
changed if the "Code Arming" feature is disabled.
To maintain the security of your system the User
Access code should be changed from the factory
default to your own unique 4-digit code. The User
Access code must not be the same as the Installer
Access code. Make a note of the new Installer Access
Code in the Alarm Record section.
Note: If no key is pressed for a period of 10s while
within the function the system will return to Standby
mode without any changes being made.
To change the User Access Code proceed as follows:
With the Control Panel in Standby Mode (Mains LED
only On),
Enter the default or current User Access Code code
.
All zone LEDs will illuminate and the Clear LED will flash.
Enter the new 4-digit User Access code
As each digit is entered, a Zone LED will extinguish in
sequence.
Press to save the new setting or
Press to exit without saving.
The system will return to Standby Mode.
TESTING THE SYSTEMTo test the system
1. ‘Arm’ the system, by pressing then , the
Exit Timer will start, press again to quick set
the system.
2. Walk in front of a PIR Movement Detector or open
a door or window fitted with a Magnetic Contact
Detector. The Control Panel Sounder & External
Siren will activate. (You can open a contact in the
Entry/Exit route, however you will have to wait for
the selected Entry Time to end before the system
will activate).
3. Return to the Control Panel and enter the User
Access Code .
The alarm will cease and the relevant Zone LED will
be illuminated.
You may test your system at any time, however, it is
recommended that the system is tested at regular
intervals not exceeding three months. Test a different
PIR /Magnetic Contact on each test occasion.
OPERATINGINSTRUCTIONS The following procedures for Arming and Disarming
the system are based upon having the "Code Arming"
feature disabled. If "Code Arming" has been enabled
during installation programming the User Access
Code will have to be correctly entered at the keypad
before the following procedures will have any effect.
‘AWAY’ ARMING ALL ZONESBefore arming the system, ensure all detectors are
unobstructed and that all doors and windows are
closed and secure.
Press .
If any Zone LED are ‘ON’, this indicates that a
door/window contact is open or movement is
being detected by a PIR on a zone being armed.
Check that all doors/windows are closed and
that PIR protected areas are clear of movement
so that only the clear LED is illuminated before
continuing the arming sequence.
When the ‘Clear’ LED only is ‘ON’, press .
The Exit tone will start. During the last ten seconds
of the Exit Delay, the tone will change pitch.
You must leave the property via the Entry/Exit
route before the Exit Delay expires, when the
tone will stop and the system will be armed.
Note: If a detector on Exit zone (zone 1) is
triggered (e.g. the exit door is opened) during the
exit delay an interrupted exit tone will be heard.
When the zone is closed again the normal exit
tone will be heard. If any detector on Zones 2, 3,
or 4 is triggered during the exit delay and warning
tone will be heard and the exit delay period will be
Note: If Code Arming has been enabled, the User
Access Code must be entered before proceding
with the following sequnce.
20 PA4 Alarm
or Current User Access Code
1 2 3 4
ARM
RESET
? ? ? ?
ARM
ARM
AWAY
ARM
AWAY
Current User Access Code
? ? ? ?
OP
ER
ATIO
N
suspended until the zone is cleared when the exit
delay will continue. All zones must be closed
when the exit delay expires or an alarm will occur.
‘HOME’ ARMING PRE-SELECTEDZONESThe ‘Home’ facility can be used to arm the system
with regularly used pre-selected Zones programmed
to be omitted.
Before arming the system, ensure all detectors are
unobstructed and that all doors and windows are
closed and secure.
Press .
If any Zone LEDs are ‘ON’, this indicates that a
door/window contact is open or movement is
being detected by a PIR on a zone being armed.
Check that all doors/windows are closed and
that PIR protected areas are clear of movement
so that only the clear LED is illuminated before
continuing the arming sequence.
When the ‘Clear’ LED only is ‘ON’, press .
The Exit tone will start. During the last ten seconds
of the Exit Delay, the tone will change pitch.
When the tone stops and the system will be armed.
ARMING WITH OCCASIONAL ZONESOMITTEDIf a system needs to be armed with a Zone
combination different to that configured for the
‘HOME’ arm setting, it is possible to select a Zone(s)
to be omitted on a temporary (one time) basis.
Before arming the system, ensure all detectors are
unobstructed and that all doors and windows are
closed and secure.
Press .
If any Zone LEDs are ‘ON’, this indicates that a
door/window contact is open or movement is
being detected by a PIR on a zone being armed.
Check that all doors/windows are closed and that
PIR protected areas are clear of movement so
that only the clear LED is illuminated before
continuing the arming sequence.
When the ‘Clear’ LED only is ‘ON’, press .
The 24Hr LED will flash.
Press buttons , or to select the
Zone(s) you wish to omit. The zone LEDs will
illuminate to indicate if the zone is omitted.
Note: The Entry/Exit Zone (Zone 1) cannot be omitted.
When the zones required to be omitted have been
selected press .
The Exit tone will start. During the last ten seconds
of the Exit Delay, the tone will change pitch.
When the tone stops and the system will be armed.
QUICK ARMAfter arming the system in either "Home" or "Away"
modes using the procedures described above the
"Quick Arm" feature may be used to cancel any
remaining exit delay period and Arm the system within
5s. This is useful for setting the system at night to
silence the exit tone after just a few seconds.
Press again while the exit tone is running to Quick
Arm the system after a few seconds.
DISARMING THE SYSTEMEnter the premises via the designated Entry route.
The Entry tone will start. During the last ten seconds
of the Entry Delay, the tone will change pitch.
Proceed directly to the Control Panel and Disarm
the system by entering the User Access Code
.
The system will disarm and the Entry tone will stop.
Note 1: To Disarm the system during Home Arming
proceed directly to the Control Panel and enter the
User Access code.
If an alarm has occurred while the system was Armed
the zone LED(s) of the zone(s)that triggered the alarm
will be illuminated, take note of Zones.
To clear any illuminated zone LEDs press .
? ? ? ?
PA4 Alarm 21
HOME
ARM
ARM
ARM
RESET
2 3 4
AWAY
OMIT
Note: If Code Arming has been enabled, the User
Access Code must be entered before proceding
with the following sequnce.
Note: If Code Arming has been enabled, the User
Access Code must be entered before proceding
with the following sequnce.
OP
ER
ATIO
N
EVENT LOGIf an alarm has occurred, the Event Log will enable the
user to recall the Zone(s) that have triggered the alarm.
The Event Log will record the last 4 alarm events.
Press .
The zone that triggered the most recent alarm will
be illuminated.
The zone that triggered the most recent alarm will
be illuminated.
Press again up to 3 times to recall the
previous 3 alarm events in sequence.
Press to return to show the most recent
alarm.
Press again to return the system to ‘Standby’
mode.
MAINTENANCEYour PA4 Intruder Alarm system requires very little
maintenance. However, a few simple tasks will ensure
its continued reliability and operation.
CONTROL PANEL AND DETECTORSThe Control Panel and detectors require no
maintenance. If cleaning is required, wipe the outside
of the casings with a soft damp cloth. Do not use
aerosols or sprays or proprietary cleaners. Do not
attempt to clean inside the units or allow water to
enter the units.
BACK-UP BATTERIESThe Optional Back-up Batteries in the Control Panel
should be replaced every 12 months or after a
prolonged power failure.
OP
ER
ATIO
N
Settings
Complete the following information during installation for future reference when adding to your system
and to assist Trouble Shooting.
PA4 ALARM RECORD
Zone Detector Type(s) Location(s) Instant/ Walk Home Delay Through Zone Omit
1 Delay N/A N/A
2
3
4
24HrTamper N/A N/A N/A
This information is highly confidential and should be kept in a very safe location.
You may make a note of your User Access Code and Installer Access Code below.
User Access Code
Purchase Date/Installation Date
Installer Access Code
Control Panel Serial Number
22 PA4 Alarm
ER
ER
RESET
RESET
24 hour fault (Internal Sounder or full alarm ifsystem is armed).
1. PIR Detector Anti-Tamper Switch not closed fully -check/refit detector cover.
2. External Siren cable connections loose or a cabledamaged.
3. 24 hour Zone wiring open eg. damaged or incorrectwiring or poor terminations.
Passive Infra Red Movement Detector notdetecting a person’s movement
1. Allow up to 4 minutes for the detector to settle downand retest.
2. ‘Pulse Count’ set too high - reset to one or two‘Pulse Count’ detection.
3. Ensure that detector is mounted the correct way up(with the cover fixing screw at the bottom).
4. Ensure that the detector is mounted at the correctheight 2.2 metres from floor.
5. Check that the detector is correctly wired.
Passive Infra Red Movement Detector false alarming
1. Ensure that the detector is not pointing at a source ofheat or a moving object.
2. Ensure that the detector is not mounted above aradiator or heater.
3. Ensure that the detector is not facing a window or indirect sunlight.
4. Check Zone wiring to detector alarm contacts.
Magnetic Contacts false alarming
1. Check that door/window closes firmly and thatmovement cannot trigger the contacts.
Magnetic Contacts not operating
1. Check that gap between Magnet and Switch Contactblocks is less than 9 mm.
2. Check Zone wiring to contacts. (All contacts on aZone must be wired in ‘Series’).
External Siren Sounding continuously (24 hourLED NOT illuminated)
1. Check for incorrect wiring to External Siren.2. Check for short-circuits in cable to siren, causing
siren to be permanently energised.
False Alarms when the system is Armed
1. Carefully note the Zone which activated the alarmbefore pressing ‘Reset’. Only the detector(s) andwiring on that Zone will need to be checked.
2. Check all Zone wiring and connectors for security.3. For PIR false alarms, consider increasing ‘Pulse
Count’ settings on suspect detector.
Mains LED is not illuminated
1. Check mains power supply.2. Check Mains Adaptor cable and connection onto
PCB.3. Mains power failure - check if other electrical circuits
are operable.
Detection Zone has been triggered but noalarm is sounding
1. Entry Delay Zone(s) triggered - alarm will sound whenthe Entry Delay Time expires.
2. Zone omitted on ‘Home’ setting.3. Zone temporarily omitted before arming.
Symptom / Recommendation Symptom / Recommendation
TROUBLE SHOOTING
PA4 Alarm 23
HELPLINEIf you have a problem with your alarm,
please call the helpline on:
01268 563273(Lines open 9.00am to 5.00pm, Monday to Friday)
ACCESSORIES
EXTENDING YOUR PA4 WIRED INTRUDERALARM SYSTEMYour system may be expanded to give additional protection by adding additional PIR Movement Detectors and
Magnetic Contact Sets.
PU2
PU3
PU1
ACCESSORY PACK - PU1The PU1 Accessory Pack comprises 2 PIR Movement Detectors, 2 Magnetic
Contact Sets and approx. 25 metres of 6 Core Cable.
PASSIVE INFRA RED MOVEMENT DETECTORS(TWIN PACK) - PU22 additional PIR Movement Detectors.
DUMMY SIREN - PU3Siren box for added visual deterant.
24 PA4 Alarm
PA4 Wired Intruder Alarm System Friedland
If you have a problem with your Alarm, please call the Helpline on:
01268 563273(Lines open 9.00am to 5.00pm, Monday to Friday).
GUARANTEENovar ED&S undertakes to replace or repair at its discretion goods
(excluding non rechargeable batteries) should they become defective
within 1 year solely as a result of faulty materials and workmanship.
Understandably if the product has not been installed, operated or
maintained in accordance with the instructions, has not been used
appropriately or if any attempt has been made to rectify, dismantle or
alter the product in any way the guarantee will be invalidated.
The guarantee states Novar ED&S entire liability. It does not extend to
cover consequential loss or damage or installation costs arising from
the defective product. This guarantee does not in any way affect the
statutory or other rights of a consumer and applies to products installed
within the UK and Eire only
If If an item develops a fault, the product must be returned to the point
of sale with:
1. Proof of purchase.
2. A full description of the fault.
3. All relevant batteries (disconnected).
Friedland is a trade mark of Novar ED&S.
Friedland, Novar Electrical Devices and SystemsThe Arnold Centre, Paycocke Road
Basildon, Essex SS14 3EA
Control Panel
● Four Detection Zones
● Tamper Zone
● Front Cover Anti-Tamper
● Zone(s) programmable for
- Entry Delay
- Walk Through
- Zone Omit
● Temporary Zone Omit facility
● Entry Delay variable 01 - 99 seconds
● Exit Delay variable 01 - 99 seconds
● Non volatile memory
● Quick arm facility
● Code arm facility selectable ON/OFF
● Individual Zone alarm activation LEDs
● Back-up Battery facilities
● Hard wired siren facility
● 4-Digit User Access Code
● 4-Digit Installer Access Code
● Plug in Mains Adaptor
External Siren
● Case material white plastic
● Piezo sounder
● Blue Lens
Magnetic ContactDetectors
● Magnetic Reed Switch operation
● Operating gap up to 9mm
● Door or window mounted
● Surface mounting, white plastic finish
PIR MovementDetectors
● Detection range up to 12 metres at 90°
● Integral Detection LED
● 1, 2, 3 ‘Pulse Count’ facility
● Anti-Tamper
● Corner or surface mount, with tilt facility
● 12 Volt dc operated, powered from the
Control Panel.
260 mm
50 mm
150 mm
MAINS CLEAR 24Hr
Zone 1 Zone 2 Zone 3 Zone 4
1 2 3
0
4 5 6
7 8 9
ARM
OMIT
RESET
HOMEERAWAY
EXIT1. Check all windows and doors are closed.2. a) Fullguard - Press 'Away' then 'Arm'.or b) Partguard - Press 'Home' then 'Arm'.3. Leave premises by entry/exit route.ENTRY1. Enter premises by entry/exit route.2. Enter your 4 digit password. If a mistake is made re-enter the correct passcode.
200 mm
75 mm
350 mm
68 mm
44 mm
58 mm
14 mm
12 mm
67 mm
45165PL Ed.3© Novar ED&S, 2004
Friedland, Novar Electrical Devices and Systems. The Arnold Centre, Paycocke Road, Basildon, Essex SS14 3EA. UK.
Novar Electrical Devices and Systems are
Quality Assurance Registered to BS EN ISO9001:2000,
by Asta
01268 563273(Lines open 9.00am to 5.00pm,
Monday to Friday).
If you have aproblem with yourAlarm, please callthe Helpline on:
RESEARCH &DEVELOPMENT
Our R & D Department is constantly
developing new products.
We practice a policy of continued
improvement and reserve the right
to change specifications without
prior notice.
COMPONENT SPECIFICATION