Upload
flitzzz
View
216
Download
0
Embed Size (px)
Citation preview
8/14/2019 50byn-3sb
1/4
Form 50BYN-3SB New
50BYN-3SB
Printed in U.S.A. 8-99 Catalog No. 515-021
Copyright 1999 Carrier Corporation Syracuse, New York 13221
50BYN024
SINGLE-PACKAGED INDOOR
AIR-COOLED VERTICAL COOLING UNIT
PERFORMANCE DATA
CERTIFIED DIMENSION PRINT
HEAD PRESSURE CONTROL ANDHEATING COIL DIMENSION PRINT
8/14/2019 50byn-3sb
2/4
Date: Supersedes 50BYN024AIR-COOLED VERTICAL PACKAGE UNIT 50BYN
Rev:
JOB NAME: LOCATION:
BUYER: BUYER P.O.# CARRIER#
UNIT NUMBER: MODEL NUMBER:
PERFORMANCE DATA CERTIFIED BY: DATE:
DESCRIPTION
These indoor single packaged air-cooled vertical units are available with optional steam or hot water heating.Units are completely factory wired, piped, and ready for installation. Units are designed for vertical or horizontalevaporator air discharge with rear air return. They are designed for ducted supply and free or ducted return appli-cations. 50BYN units have an internal air-cooled condenser with condenser air inlet and discharge on the sameface of the unit. These fully painted vertical package units offer economical air conditioning for offices, restau-rants, cinemas, factories, warehouses, retail shops, and spot cooling applications.
FEATURES
Standard one-year product warranty.Four-year optional extended protection plan for the motor compressorSide access filter frame for 1 or 2 disposable type filters. No toolsrequired to change filters.Three-phase TEFC (Totally Enclosed Fan Cooled) evaporator andcondenser fan motor with same voltage as unit. It has internal thermaloverload protection and permanently lubricated bearings.Built in 24-volt control system.Adjustable belt drive centrifugal forward curve fans on evaporator andcondenser are statically and dynamically balanced.Carrier scroll compressor mounted on vibration isolation.Acoustically lined compressor compartment.Two-stage capacity control. Unit has 3 independent circuits and can beoperated as 3-stage control.Cycle-LOC and 5-minute Time Guard protection on each circuit.
High and low pressure switches on each circuit.Replaceable filter drier in each circuit.Adjustable thermostatic expansion valves.Sloped condensate pan and double wall construction in evaporatorsection for optimum indoor-air quality.Dual drain connections for condensate pan overflow protection.Units are vertical air discharge or may be field converted to horizontaldischarge.Return may be free blow or ductedAll units are UL and UL, Canada listed and rated in accordance withARI 360.All service may be done through the front of the unit.Baked enamel painted cabinet meets 500-hr salt spray requirements.Coils are aluminum plate fin mechanically bonded to copper tubes.Unit manufactured in ISO 9002 facility.
PERFORMANCE DATA
Operating Weight _______________________________________ lbCOOLING:
Gross Total Capacity _________________________________ BtuhGross Sensible Capacity_______________________________ BtuhOutdoor Design db_______________Indoor Entering Air db ________ wb ____________Indoor Leaving Air db ________ wb ____________Outdoor cfm ____________________________________________Condenser ESP______________________________________in. wgRpm _________ Bhp _______Evaporator-Fan cfm ______________________________________ESP_______________________________________________in. wgRpm _________ Bhp________
ACCESSORY HEATING DATA
_____________ Hot water ______ SteamAccessory Heating Coil Capacity_________________________BtuhOutdoor Design db_______________________________________FIndoor Entering Air db ________ F Leaving_____________ db FGpm __________ Ewt _______ F Lwt ______ FPressure Drop______________________________________ft waterSteam Pressure_______________________________________ PsigCoil Air Pressure Drop______________________________in. water
ELECTRICAL DATA
Unit Power Supply _________ Volts ________ Ph _________ HzCompressor 1 _________ RLA _________ FLACompressor 2 _________ RLA _________ FLACompressor 3 _________ RLA _________ FLA
Evaporator Fan Motor ______ FLA Motor Hp _________Condenser Fan Motor ______ FLA Motor Hp _________Minimum Circuit Amps____________________________________Maximum Overcurrent Protection Amps_______________________
ACCESSORIES
Low Ambient Damper Thermostat __________________________________________ Hot Water Heating Coil ___________________________ Rows Steam Heating Coil ______________________________ Rows
___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________
8/14/2019 50byn-3sb
3/4
C U
T A L O N G
D O T T E D L I N E
C U T A L O N G
D O T T E D L I N E
C E R T I F I E D D I M E N S I O N P R I N T
C O R N E R W E I G H T S
C O R N E R
5 0 B Y N 0 2 4
k g
l b
A
1 8 3
4 0 3
B
1 9 4
4 2 8
C
1 9 2
4 2 4
D
1 8 1
4 0 0
N O T E S :
1 .
D i m e n s
i o n s
i n [
] a r e
i n m
i l l i m e
t e r s .
2 .
C e n
t e r o
f g r a v i
t y .
3 .
D i r e c
t i o n o f a
i r f l o w .
4 .
O n e s
i d e o
f u n
i t m u s
t h a v e m
i n i m u m
o f
3
[ 9 1 4 ]
c l e a r a n c e
f o r
f i l t e r
r e m o v a
l .
D I M E N S I O N A L C H A R T
D I M
5 0 B Y N 0 2 4
m m
f t - i n .
A
2 3 4 1
7 -
8 1 / 4
B
2 1 0 8
6 - 1
1
C
7 9 4
2 -
7 1 / 4
D
8 7 2
2 - 1
0 3 / 8
E
5 8 1
1 - 1
0 7 / 8
F
1 8 4
0 -
7 1 / 4
G
4 0 6
1 -
4
H
3 7 9
1 -
3
J
8 3 0
2 -
8 5 / 8
K
7 9 6
2 -
7 1 / 4
L
5 8 4
1 - 1
1
M
2 8
0 -
1 1 / 8
N
4 0
0 -
1 5 / 8
P
5 1
0 -
2
Q
4 3
0 -
1 3 / 4
R
8 0 5
2 -
7 3 / 4
S
6 5
0 -
2 1 / 2
T
4 5 7
1 -
6
V
1 6
0 -
0 5 / 8
W
9 2 1
3 -
0 1 / 4
X
6 1 0
2 -
0
Y
2 0 2
0 -
8
Z
8 6
0 -
3 3 / 8
A A
4 2 2
1 -
4 5 / 8
A B
1 4 0
0 -
5 1 / 2
A C
6 0
0 -
2 3 / 8
A D
2 1
0 -
0 7 / 8
A E
2 2 6
0 -
8 7 / 8
A F
1 8 4
0 -
7 1 / 4
A G
2 2 0
0 -
8 3 / 4
A H
6 2
0 -
2 1 / 2
A J
1 9 8 4
6 -
6 1 / 8
A K
3 4 5
1 -
1 5 / 8
A L
5 3 0
1 -
8 7 / 8
A M
3 5 6
1 -
2
A N
5 3 0
1 -
8 7 / 8
A P
7 6
0 -
3
A Q
1 9 5 6
6 -
5
A R
4 1
0 -
1 5 / 8
A S
1 0 8 5
3 -
6 3 / 4
A T
3 9 9
1 -
3 3 / 4
A V
3 1 4
1 -
0 3 / 8
A W
2 3 6
0 -
9 1 / 4
A X
5 0
0 -
2
A Y
1 4 7 1
4 - 1
0
8/14/2019 50byn-3sb
4/4
C E R T I F I E D H E A D P R E S S U R E
C O N T R O L A N D H E A T I N G C O I L D I M E N S I O N P R I N T
D I M E N S I O N A L C H A R T
D I M
U N I T 5 0 B Y 0 2 4
m m
f t - i n .
A
5 6 0
1 - 1 0
1 / 1
6
B
2 0 1 4
6 - 6
5 / 1
6
C
2 8 6
0 - 1 1 1 / 4
H O T W A T E R C O I L
D
2 4 2
0 - 9
1 / 2
E
1 3 3
0 - 5
1 / 4
F
9 5
0 - 3
3 / 4
G
7 6 2
2 - 6
H
8 9
0 - 3
1 / 2
J ( r e t u r n
)
6 4
0 - 2
1 / 2
K ( s u p p
l y )
6 4
0 - 2
1 / 2
L
3 2
0 - 1 1 / 4
S T E A M C O I L
D
2 0 3
0 - 8
E
6 4
0 - 2
1 / 2
F
4 5 4
1 - 5
7 / 8
G
3 1 4
1 - 0
3 / 8
H
8 9
0 - 3
1 / 2
J ( s u p p
l y )
5 1
0 - 2
K ( r e t u r n
)
3 8
0 - 1 1 / 2
L
6 4
0 - 2
1 / 2