Upload
linn-liu
View
82
Download
0
Embed Size (px)
Citation preview
Control Components
CJT1 Series AC Contactor CJ12 Series AC Contactor
CJC20 Series AC ContactorCJ20 Series AC Contactor
CJ40 Series AC Contactor CJX1 Series AC Contactor
CJX2 Series AC Contactor CJX5 Series AC Contactor
Confirms to: GB14048.4, IEC60947-4-1
Rated operating current: 5A~150A
Rated operating voltage: 380V
Number of pole: 3P
Control voltage of coil: AC24V/36V/48V/110V/
127V/220V/380V
Combination of auxiliary contacts group: 2NO2NC
www.peopleelectric.com 030
Confirms to: GB14048.4, IEC60947-4-1
Rated operating current: 100A~630A
Rated operating voltage: 380V
Number of pole: 2P, 3P, 4P, 5P
Control voltage of coil: AC24V/36V/48V/110V/
127V/220V/380V
Combination of auxiliary contacts group: 3NO3NC
Confirms to: GB14048.4, IEC60947-4-1
Rated operating current: 10A~630A
Rated operating voltage: 220V, 380V, 660V
Number of pole: 3P
Control voltage of coil: AC24V/36V/48V/110V/
127V/220V/380V/440V/660V
Combination of auxiliary contacts group:
2NO2NC (10~160A), 3NO3NC (250A~630A)
Confirms to: GB14048.4, IEC60947-4-1
Rated operating current: 63A~630A
Rated operating voltage: 220V, 380V, 660V
Number of pole: 3P
Control voltage of coil: AC24V/36V/48V/110V/
127V/220V/380V/440V/660V
Combination of auxiliary contacts group:
1NO1NC (63~160A), 2NO2NC (250A~630A)
Confirms to: GB14048.4, IEC60947-4-1
Rated operating current: 10A~1000A
Rated operating voltage: 220V, 380V, 660V
Number of pole: 3P
Control voltage of coil: AC24V/36V/48V/110V/
127V/220V/380V/440V/660V
Combination of auxiliary contacts group:
2NO2NC (10~250A), 3NO3NC (315A~1000A)
Confirms to: GB14048.4, IEC60947-4-1
Rated operating current: 9A~400A
Rated operating voltage: 220V, 380V, 660V
Number of pole: 3P
Control voltage of coil: AC24V/36V/48V/110V/
127V/220V/380V/440V/660V
Combination of auxiliary contacts group: 2NO2NC
Confirms to: GB14048.4, IEC60947-4-1
Rated operating current: 9A~630A
Rated operating voltage: 220V, 380V, 660V
Number of pole: 3P
Control voltage of coil: AC24V/36V/48V/110V/
127V/220V/380V/440V/660V
Confirms to: GB14048.4, IEC60947-4-1
Rated operating current: 9A~105A
Rated operating voltage: 220V, 380V, 660V
Number of pole: 3P
Control voltage of coil: AC24V/36V/48V/110V/
127V/220V/380V/440V/660V
Control Components
CJT1 Series AC Contactor CJ12 Series AC Contactor
CJC20 Series AC ContactorCJ20 Series AC Contactor
CJ40 Series AC Contactor CJX1 Series AC Contactor
CJX2 Series AC Contactor CJX5 Series AC Contactor
Confirms to: GB14048.4, IEC60947-4-1
Rated operating current: 5A~150A
Rated operating voltage: 380V
Number of pole: 3P
Control voltage of coil: AC24V/36V/48V/110V/
127V/220V/380V
Combination of auxiliary contacts group: 2NO2NC
www.peopleelectric.com 030
Confirms to: GB14048.4, IEC60947-4-1
Rated operating current: 100A~630A
Rated operating voltage: 380V
Number of pole: 2P, 3P, 4P, 5P
Control voltage of coil: AC24V/36V/48V/110V/
127V/220V/380V
Combination of auxiliary contacts group: 3NO3NC
Confirms to: GB14048.4, IEC60947-4-1
Rated operating current: 10A~630A
Rated operating voltage: 220V, 380V, 660V
Number of pole: 3P
Control voltage of coil: AC24V/36V/48V/110V/
127V/220V/380V/440V/660V
Combination of auxiliary contacts group:
2NO2NC (10~160A), 3NO3NC (250A~630A)
Confirms to: GB14048.4, IEC60947-4-1
Rated operating current: 63A~630A
Rated operating voltage: 220V, 380V, 660V
Number of pole: 3P
Control voltage of coil: AC24V/36V/48V/110V/
127V/220V/380V/440V/660V
Combination of auxiliary contacts group:
1NO1NC (63~160A), 2NO2NC (250A~630A)
Confirms to: GB14048.4, IEC60947-4-1
Rated operating current: 10A~1000A
Rated operating voltage: 220V, 380V, 660V
Number of pole: 3P
Control voltage of coil: AC24V/36V/48V/110V/
127V/220V/380V/440V/660V
Combination of auxiliary contacts group:
2NO2NC (10~250A), 3NO3NC (315A~1000A)
Confirms to: GB14048.4, IEC60947-4-1
Rated operating current: 9A~400A
Rated operating voltage: 220V, 380V, 660V
Number of pole: 3P
Control voltage of coil: AC24V/36V/48V/110V/
127V/220V/380V/440V/660V
Combination of auxiliary contacts group: 2NO2NC
Confirms to: GB14048.4, IEC60947-4-1
Rated operating current: 9A~630A
Rated operating voltage: 220V, 380V, 660V
Number of pole: 3P
Control voltage of coil: AC24V/36V/48V/110V/
127V/220V/380V/440V/660V
Confirms to: GB14048.4, IEC60947-4-1
Rated operating current: 9A~105A
Rated operating voltage: 220V, 380V, 660V
Number of pole: 3P
Control voltage of coil: AC24V/36V/48V/110V/
127V/220V/380V/440V/660V
031 www.peopleelectric.com
Confirms to: GB14048.4, IEC60947-4-1
Rated operating current: 9A~370A
Rated operating voltage: 220V, 380V, 660V
Number of pole: 3P
Control voltage of coil: AC24V/36V/48V/110V/
127V/220V/380V/440V/660V
CJX8 Series AC Contactor RDC30 Series AC Contactor
RDC6 Series AC Contactor CJX2-Z Series DC Operated Contactor
Confirms to: GB14048.4, IEC60947-4-1
Rated operating current: 9A~80A
Rated operating voltage: 220V, 380V, 660V
Number of pole: 3P
Control voltage of coil: AC24V/36V/48V/110V/
127V/220V/380V/440V/660V
Confirms to: GB14048.4, IEC60947-4-1
Rated operating current: 9A~95A
Rated operating voltage: 220V, 380V, 660V
Number of pole: 3P
Control voltage of coil: AC24V/36V/48V/110V/
127V/220V/380V/440V/660V
Confirms to: GB14048.4, IEC60947-4-1
Rated operating current: 9A~95A
Rated operating voltage: 220V, 380V, 660V
Number of pole: 3P
Control voltage of coil: DC24V/36V/48V/110V/
127V/230V
RDZJ Series DC Contactor CJX8-C Series Switching Capacitor Contactor
RDC19 Series Switching Capacitor Contactor
RDC19B Series Switching Capacitor Contactor
Confirms to: GB14048.4
Rated operating current: 50A~600A
Control voltage of coil:DC12V/24V/36V/40V/48V/60VConfirms to: GB14048.4
Setting thermal current: 32A~85A
When AC-6b, 380V, controllable capacitor ’s capacity:
15~50kvar
Rated insulation voltage: 500V
Rated operating voltage: 380V
Number of pole: 3P
Control voltage of coil: AC 24V/36V/48V/110V/127V/
220V/380V/440V
Confirms to: GB14048.4
Setting thermal current: 25A~43A
When AC-6b, 380V, controllable capacitor ’s capacity:
12~20kvar
Rated insulation voltage: 660V
Rated operating voltage: 380V
Number of pole: 3P
Control voltage of coil: AC 24V/36V/48V/110V/127V/
220V/380V/440V
Confirms to: GB14048.4
Setting thermal current: 25A~108A
When AC-6b, 380V, controllable capacitor ’s capacity:
12~50kvar
Rated insulation voltage: 660V
Rated operating voltage: 380V
Number of pole: 3P
Control voltage of coil: AC 24V/36V/48V/110V/127V/
220V/380V/440V/660
www.peopleelectric.com 032
CKJ5 Series Low Voltage Vacuum Contactor
PGV Series Motor Protection CircuitBreaker
JZC4 Series Intermediate Relay JZC4-Z Series Intermediate Relay
JZ7 Series Intermediate Relay DZ Series Intermediate Relay
JRS1 Series Thermal Overload Relay JRS2 Series Thermal Overload Relay
Confirms to: GB14048.4, IEC60947-4-1
Rated operating current: 80A~630A
Rated insulation voltage: 1140V
Rated operating voltage: 380V
Number of pole: 3P
Confirms to: GB14048.5, IEC60947-5-1
Setting thermal current: 20A
Rated operating voltage: 690V
Combination of auxiliary contacts: 22/31/40
Control voltage of coil: AC 24V/36V/48V/110V/
127V/220V/380V/440V/660
Confirms to: GB14048.5
Setting thermal current: 20A
Rated operating voltage: 690V
Combination of auxiliary contacts: 22/31/40
Control voltage of coil: DC 24V/36V/48V/110V/
127V/230V
, IEC60947-5-1
Confirms to: GB14048.5, IEC60947-5-1
Setting thermal current: 5A
Rated operating voltage: 380V
Combination of auxiliary contacts: 44/53/62/71/80
Control voltage of coil: AC 24V/36V/48V/110V/
127V/220V/380V
Operation mode: “Y” DC voltage operation, “L” DC current
operation, “J” AC voltage operation, “B” with keeping winding
“S” Delay, “K” Fast action
Rated voltage of DZY: DC 12V~220V
Rated current of DZL: DC 0.25A~8A
Rated voltage of DZJ: AC 12V~380V
Rated current of DZB: DC 0.25A~8A
Rated voltage of DZB: DC 12V~220V
Rated voltage of DZS: DC 24V~220V
Rated current of DZK: DC 0.25A~8A
Rated voltage of DZK: DC 24V~220V
Confirms to: IEC60947-4-1
Rated insulation voltage: 690V
Rated operating voltage: 380V
Rated impact withstand voltage: 8kV
Rated current: 0.1A~80A
Auxiliary contacts: 1NO+1NC
Suited contactor: CJX2
Confirms to: IEC60947-4-1
Rated insulation voltage: 690V
Rated operating voltage: 690V
Rated current: 0.1A~630A
Auxiliary contacts: 1NO+1NC
Suited contactor: CJX1
Confirms to: IEC60947-2, IEC60947-4-1
Setting Range: 0.1~80A
Rated operating voltage: 690V
Rated frequency: 50/60Hz
Control Components
031 www.peopleelectric.com
Confirms to: GB14048.4, IEC60947-4-1
Rated operating current: 9A~370A
Rated operating voltage: 220V, 380V, 660V
Number of pole: 3P
Control voltage of coil: AC24V/36V/48V/110V/
127V/220V/380V/440V/660V
CJX8 Series AC Contactor RDC30 Series AC Contactor
RDC6 Series AC Contactor CJX2-Z Series DC Operated Contactor
Confirms to: GB14048.4, IEC60947-4-1
Rated operating current: 9A~80A
Rated operating voltage: 220V, 380V, 660V
Number of pole: 3P
Control voltage of coil: AC24V/36V/48V/110V/
127V/220V/380V/440V/660V
Confirms to: GB14048.4, IEC60947-4-1
Rated operating current: 9A~95A
Rated operating voltage: 220V, 380V, 660V
Number of pole: 3P
Control voltage of coil: AC24V/36V/48V/110V/
127V/220V/380V/440V/660V
Confirms to: GB14048.4, IEC60947-4-1
Rated operating current: 9A~95A
Rated operating voltage: 220V, 380V, 660V
Number of pole: 3P
Control voltage of coil: DC24V/36V/48V/110V/
127V/230V
RDZJ Series DC Contactor CJX8-C Series Switching Capacitor Contactor
RDC19 Series Switching Capacitor Contactor
RDC19B Series Switching Capacitor Contactor
Confirms to: GB14048.4
Rated operating current: 50A~600A
Control voltage of coil:DC12V/24V/36V/40V/48V/60VConfirms to: GB14048.4
Setting thermal current: 32A~85A
When AC-6b, 380V, controllable capacitor ’s capacity:
15~50kvar
Rated insulation voltage: 500V
Rated operating voltage: 380V
Number of pole: 3P
Control voltage of coil: AC 24V/36V/48V/110V/127V/
220V/380V/440V
Confirms to: GB14048.4
Setting thermal current: 25A~43A
When AC-6b, 380V, controllable capacitor ’s capacity:
12~20kvar
Rated insulation voltage: 660V
Rated operating voltage: 380V
Number of pole: 3P
Control voltage of coil: AC 24V/36V/48V/110V/127V/
220V/380V/440V
Confirms to: GB14048.4
Setting thermal current: 25A~108A
When AC-6b, 380V, controllable capacitor ’s capacity:
12~50kvar
Rated insulation voltage: 660V
Rated operating voltage: 380V
Number of pole: 3P
Control voltage of coil: AC 24V/36V/48V/110V/127V/
220V/380V/440V/660
www.peopleelectric.com 032
CKJ5 Series Low Voltage Vacuum Contactor
PGV Series Motor Protection CircuitBreaker
JZC4 Series Intermediate Relay JZC4-Z Series Intermediate Relay
JZ7 Series Intermediate Relay DZ Series Intermediate Relay
JRS1 Series Thermal Overload Relay JRS2 Series Thermal Overload Relay
Confirms to: GB14048.4, IEC60947-4-1
Rated operating current: 80A~630A
Rated insulation voltage: 1140V
Rated operating voltage: 380V
Number of pole: 3P
Confirms to: GB14048.5, IEC60947-5-1
Setting thermal current: 20A
Rated operating voltage: 690V
Combination of auxiliary contacts: 22/31/40
Control voltage of coil: AC 24V/36V/48V/110V/
127V/220V/380V/440V/660
Confirms to: GB14048.5
Setting thermal current: 20A
Rated operating voltage: 690V
Combination of auxiliary contacts: 22/31/40
Control voltage of coil: DC 24V/36V/48V/110V/
127V/230V
, IEC60947-5-1
Confirms to: GB14048.5, IEC60947-5-1
Setting thermal current: 5A
Rated operating voltage: 380V
Combination of auxiliary contacts: 44/53/62/71/80
Control voltage of coil: AC 24V/36V/48V/110V/
127V/220V/380V
Operation mode: “Y” DC voltage operation, “L” DC current
operation, “J” AC voltage operation, “B” with keeping winding
“S” Delay, “K” Fast action
Rated voltage of DZY: DC 12V~220V
Rated current of DZL: DC 0.25A~8A
Rated voltage of DZJ: AC 12V~380V
Rated current of DZB: DC 0.25A~8A
Rated voltage of DZB: DC 12V~220V
Rated voltage of DZS: DC 24V~220V
Rated current of DZK: DC 0.25A~8A
Rated voltage of DZK: DC 24V~220V
Confirms to: IEC60947-4-1
Rated insulation voltage: 690V
Rated operating voltage: 380V
Rated impact withstand voltage: 8kV
Rated current: 0.1A~80A
Auxiliary contacts: 1NO+1NC
Suited contactor: CJX2
Confirms to: IEC60947-4-1
Rated insulation voltage: 690V
Rated operating voltage: 690V
Rated current: 0.1A~630A
Auxiliary contacts: 1NO+1NC
Suited contactor: CJX1
Confirms to: IEC60947-2, IEC60947-4-1
Setting Range: 0.1~80A
Rated operating voltage: 690V
Rated frequency: 50/60Hz
Control Components
033 www.peopleelectric.com
JRS5 Series Thermal Overload Relay
Confirms to: IEC60947-4-1
Rated insulation voltage: 690V
Rated operating voltage: 380V
Rated current: 0.28A~105A
Auxiliary contacts: 1NO+1NC
Suited contactor: CJX5
Confirms to: IEC60947-4-1
Rated insulation voltage: 690V
Rated operating voltage: 660V
Rated current: 0.11A~500A
Auxiliary contacts: 1NO+1NC
Suited contactor: CJX8
JRS8 Series Thermal Overload Relay
RDJ2 Series Thermal Overload Relay
Confirms to: IEC60947-4-1
Rated insulation voltage: 690V
Rated operating voltage: 380V
Rated current: 0.1A~630A
Auxiliary contacts: 1NO+1NC
Suited contactor: CJX2
JR20 Series Thermal Overload Relay
Confirms to: IEC60947-4-1
Rated insulation voltage: 690V
Rated operating voltage: 660V
Rated current: 0.1A~630A
Auxiliary contacts: 1NO+1NC
Suited contactor: CJ20
JR36 Series Thermal Overload Relay
Confirms to: IEC60947-4-1
Rated insulation voltage: 690V
Rated operating voltage: 660V
Rated current: 0.35A~160A
Auxiliary contacts: 1NO+1NC
Suited contactor: CJT1
RDR6 Series Thermal Overload Relay
Confirms to: IEC60947-4-1
Rated insulation voltage: 690V
Rated operating voltage: 380V
Rated current: 0.1A~93A
Auxiliary contacts: 1NO+1NC
Suited contactor: CJX2
RDJD8 Series Residual Current Operated Relay
RDT8 Series Time Relay
Confirms to: GB/T22387
Rated operating voltage: AC 220V/AC 380V
Rated current: 250A, 400A, 630A
Rated residual operated current: 50mA~500mA
(adjustable)
It can be combined with AC contactor or circuit
breaker into leakage protective device
Voltage range: AC/DC 12-240V
Rated frequency: 50/60Hz
Number of contacts: 1×SPDT, 2×SPDT
Scope of delay: 0.1s - 10 days
DIN rail mounting
www.peopleelectric.com 034
ZN48 Series Time Relay
Confirms to: GB14048.5
Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V
Form of contacts: 1 sets of conversion
Scope of delay: 0.01s~99h59m
Counter range: 1~99999999
Ranges of accumulated time: 9999d23h59m
JS11S, JSS1P1, DH11S Series Time Relay
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V
Form of action: delay when electrified with instantly-acting
contacts
Form of contacts: instantly-acting 1 conversion and delay 2
conversion
Scope of delay: 0.01s~9999h
JS14A Series Time Relay
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V
Form of action: delay when electrified
Form of contacts: delay 2 conversion
Scope of delay: 1s, 5s, 10s, 30s, 60s, 120s, 180s 300s, 600s, 900s, 1800s, 3600s
JS20 Series Time Relay
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V
Form of action: delay when electrified
Form of contacts: delay 2 conversion
Scope of delay: 1s, 5s, 10s, 30s, 60s, 120s, 180s 300s, 600s, 900s, 1800s, 3600s
JS14C, JS14S, DH14S Series Time Relay
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V
Form of action: delay when electrified
Form of contacts: delay 2 conversion
Scope of delay: 0.01s~9999h
JS14P Series Time Relay
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V
Form of action: delay when electrified
Form of contacts: delay 2 conversion
Scope of delay: 0.01s~9999h
It can directly replace JS14A, JS20 etc. series
time relay
JSS1 Series Time Relay
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V
Form of action: delay when electrified, cycle delay
Form of contacts: delay 2 conversion
Scope of delay: 0.1s~9.9s, 0.1s~99.9s, 0.1s~999.9s 1s~99s, 1s~999s, 1s~9999s, 1s~99990s, 10s~990s, 10s~9990s, 1min~99min, 1min~999min, 1min~9999min
JSS72 Series Time Relay
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V
Form of action: delay when electrified
Form of contacts: delay 2 conversion
Scope of delay: 0.01s~9999h
Control Components
033 www.peopleelectric.com
JRS5 Series Thermal Overload Relay
Confirms to: IEC60947-4-1
Rated insulation voltage: 690V
Rated operating voltage: 380V
Rated current: 0.28A~105A
Auxiliary contacts: 1NO+1NC
Suited contactor: CJX5
Confirms to: IEC60947-4-1
Rated insulation voltage: 690V
Rated operating voltage: 660V
Rated current: 0.11A~500A
Auxiliary contacts: 1NO+1NC
Suited contactor: CJX8
JRS8 Series Thermal Overload Relay
RDJ2 Series Thermal Overload Relay
Confirms to: IEC60947-4-1
Rated insulation voltage: 690V
Rated operating voltage: 380V
Rated current: 0.1A~630A
Auxiliary contacts: 1NO+1NC
Suited contactor: CJX2
JR20 Series Thermal Overload Relay
Confirms to: IEC60947-4-1
Rated insulation voltage: 690V
Rated operating voltage: 660V
Rated current: 0.1A~630A
Auxiliary contacts: 1NO+1NC
Suited contactor: CJ20
JR36 Series Thermal Overload Relay
Confirms to: IEC60947-4-1
Rated insulation voltage: 690V
Rated operating voltage: 660V
Rated current: 0.35A~160A
Auxiliary contacts: 1NO+1NC
Suited contactor: CJT1
RDR6 Series Thermal Overload Relay
Confirms to: IEC60947-4-1
Rated insulation voltage: 690V
Rated operating voltage: 380V
Rated current: 0.1A~93A
Auxiliary contacts: 1NO+1NC
Suited contactor: CJX2
RDJD8 Series Residual Current Operated Relay
RDT8 Series Time Relay
Confirms to: GB/T22387
Rated operating voltage: AC 220V/AC 380V
Rated current: 250A, 400A, 630A
Rated residual operated current: 50mA~500mA
(adjustable)
It can be combined with AC contactor or circuit
breaker into leakage protective device
Voltage range: AC/DC 12-240V
Rated frequency: 50/60Hz
Number of contacts: 1×SPDT, 2×SPDT
Scope of delay: 0.1s - 10 days
DIN rail mounting
www.peopleelectric.com 034
ZN48 Series Time Relay
Confirms to: GB14048.5
Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V
Form of contacts: 1 sets of conversion
Scope of delay: 0.01s~99h59m
Counter range: 1~99999999
Ranges of accumulated time: 9999d23h59m
JS11S, JSS1P1, DH11S Series Time Relay
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V
Form of action: delay when electrified with instantly-acting
contacts
Form of contacts: instantly-acting 1 conversion and delay 2
conversion
Scope of delay: 0.01s~9999h
JS14A Series Time Relay
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V
Form of action: delay when electrified
Form of contacts: delay 2 conversion
Scope of delay: 1s, 5s, 10s, 30s, 60s, 120s, 180s 300s, 600s, 900s, 1800s, 3600s
JS20 Series Time Relay
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V
Form of action: delay when electrified
Form of contacts: delay 2 conversion
Scope of delay: 1s, 5s, 10s, 30s, 60s, 120s, 180s 300s, 600s, 900s, 1800s, 3600s
JS14C, JS14S, DH14S Series Time Relay
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V
Form of action: delay when electrified
Form of contacts: delay 2 conversion
Scope of delay: 0.01s~9999h
JS14P Series Time Relay
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V
Form of action: delay when electrified
Form of contacts: delay 2 conversion
Scope of delay: 0.01s~9999h
It can directly replace JS14A, JS20 etc. series
time relay
JSS1 Series Time Relay
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V
Form of action: delay when electrified, cycle delay
Form of contacts: delay 2 conversion
Scope of delay: 0.1s~9.9s, 0.1s~99.9s, 0.1s~999.9s 1s~99s, 1s~999s, 1s~9999s, 1s~99990s, 10s~990s, 10s~9990s, 1min~99min, 1min~999min, 1min~9999min
JSS72 Series Time Relay
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V
Form of action: delay when electrified
Form of contacts: delay 2 conversion
Scope of delay: 0.01s~9999h
Control Components
035 www.peopleelectric.com
JJSB1 Series Time Relay
Confirms to: GB14048.5
Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V
Form of action: delay when electrified
Form of contacts: delay 2 conversion
Scope of delay: 1s, 5s, 10s, 30s, 60s, 120s, 180s 300s, 600s, 900s, 1800s, 3600s
DH48S Series Time Relay
Confirms to: GB14048.5
Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V
Form of action: delay when electrified, DH48S-S is cycle delay
Form of contacts: DH48S is delay 1 conversion, DH48S-2H is instantly acting 1 conversion and delay 1 conversion, DH48S-2Z is delay 2 conversion
Scope of delay: 0.01s~99h99m
RDS3 Series Time Relay
Confirms to: GB14048.5
Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V
Form of action: delay when electrified or cycle delay
Form of contacts: delay 2 conversion or delay 1
conversion, instantly acting 1 conversion
Scope of delay: sec: 1, 5, 10, 30, 60, min: 3, 6, 10, 30, 60
Installation mode: panel type or device type
AH3 Series Time Relay
Confirms to: GB14048.5
Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V
Form of action: delay when electrified
Form of contacts: AH3-1 is delay 1 conversion, AH3-2 is delay 2 conversion, AH3-3 is instantly acting 1 conversion, delay 1 conversion
Scope of delay: sec: 1, 5, 10, 30, 60, min: 3, 6, 10, 30, 60
ST3P Series Time Relay
Confirms to: GB14048.5
Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V
Form of action: T3PA is delay when electrified ST3PF is delay when break, ST3PR is cycle delay
Form of contacts: ST3PA is delay 2 conversion, ST3PC is instantly acting conversion, delay 1 conversion, ST3PF is delay 1 conversion
Scope of delay: ST3PR: 1s~3600s, ST3PF: 1s~180s ST3PA (C)-A~F:0.5s~24h
ST6P Series Time Relay
Confirms to: GB14048.5
Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V
Form of action: delay when electrified
Form of contacts: ST6P-2 is delay 2 conversion,
ST6P-3 is delay 3 conversion, ST6P-4 is delay 4 conversion
Scope of delay: 1s~2h
JS7 Series Time Relay
Confirms to: GB14048.5
Rated operating voltage: AC 220V/380V
Form of action: JS7-1/2/3 is delay when electrified
JS7-4/5 is delay when break
Form of contacts: JS7-1/3/5 is delay 1 conversion,
JS7-2/4 is instantly acting 1 conversion delay 1 conversion
Scope of delay: 30s, 60s, 120s, 180s
DS Series Time Relay
Confirms to: GB14048.5
Rated insulation voltage: 380V
Rated voltage: up to 380V, DC 250V
www.peopleelectric.com 036
DL, DY Series Current Voltage Relay
Setting scope of DL (A): 0.0025~0.01, 0.01~0.04 0.0125~0.05, 0.05~0.2 0.15~0.6, 0.5~2, 1.5~6 2.5~10, 5~20, 12.5~50
Voltage setting scope of DY (Y): 15~60, 12~48 40~160, 50~200 80~320, 100~400
JL12 Series Current Relay
Confirms to: GB14048.5
Rated voltage: 380V
Rated current of coil: 5A~300A
JL14 Series Current Relay
Confirms to: GB14048.5
Rated voltage: AC380V, DC220V
Rated current of coil: 1A~600A
JL15 Series Current Relay
Confirms to: GB14048.5
Rated voltage: AC380V, DC440V
Rated current of coil: 1A~600A
JL18 Series Current Relay
Confirms to: GB14048.5
Rated voltage: AC380V, DC440V
Rated current of coil: 1A~630A
DX Series Signal Relay
Rated voltage: 12V, 24V, 48V, 110V, 220V
Rated current: 0.01A~4A
HH52P, 53P, 54P Series General Relay
Confirms to: GB14048.5, IEC61810-1
Rated insulation voltage: 380V
Voltage of coil: up to AC 380V, DC 220V
Group no. of contacts: HH52P has 2 groups of contacts HH53P has 3 groups of contacts HH54P has 4 groups of contacts
Control voltage of coil: AC 6V~380V DC 6V~220V
JQX Series General Relay
Confirms to: GB14048.5, IEC61810-1
Rated operating voltage: AC 220V, 380V, DC220V
Voltage of coil: up to AC380V, DC220V
Group no. of contacts: 2Z is 2 groups of contacts, 3Z is 3 groups of contacts
Control voltage of coil: AC6V~380V DC6V~220V
Control Components
035 www.peopleelectric.com
JJSB1 Series Time Relay
Confirms to: GB14048.5
Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V
Form of action: delay when electrified
Form of contacts: delay 2 conversion
Scope of delay: 1s, 5s, 10s, 30s, 60s, 120s, 180s 300s, 600s, 900s, 1800s, 3600s
DH48S Series Time Relay
Confirms to: GB14048.5
Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V
Form of action: delay when electrified, DH48S-S is cycle delay
Form of contacts: DH48S is delay 1 conversion, DH48S-2H is instantly acting 1 conversion and delay 1 conversion, DH48S-2Z is delay 2 conversion
Scope of delay: 0.01s~99h99m
RDS3 Series Time Relay
Confirms to: GB14048.5
Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V
Form of action: delay when electrified or cycle delay
Form of contacts: delay 2 conversion or delay 1
conversion, instantly acting 1 conversion
Scope of delay: sec: 1, 5, 10, 30, 60, min: 3, 6, 10, 30, 60
Installation mode: panel type or device type
AH3 Series Time Relay
Confirms to: GB14048.5
Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V
Form of action: delay when electrified
Form of contacts: AH3-1 is delay 1 conversion, AH3-2 is delay 2 conversion, AH3-3 is instantly acting 1 conversion, delay 1 conversion
Scope of delay: sec: 1, 5, 10, 30, 60, min: 3, 6, 10, 30, 60
ST3P Series Time Relay
Confirms to: GB14048.5
Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V
Form of action: T3PA is delay when electrified ST3PF is delay when break, ST3PR is cycle delay
Form of contacts: ST3PA is delay 2 conversion, ST3PC is instantly acting conversion, delay 1 conversion, ST3PF is delay 1 conversion
Scope of delay: ST3PR: 1s~3600s, ST3PF: 1s~180s ST3PA (C)-A~F:0.5s~24h
ST6P Series Time Relay
Confirms to: GB14048.5
Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V
Form of action: delay when electrified
Form of contacts: ST6P-2 is delay 2 conversion,
ST6P-3 is delay 3 conversion, ST6P-4 is delay 4 conversion
Scope of delay: 1s~2h
JS7 Series Time Relay
Confirms to: GB14048.5
Rated operating voltage: AC 220V/380V
Form of action: JS7-1/2/3 is delay when electrified
JS7-4/5 is delay when break
Form of contacts: JS7-1/3/5 is delay 1 conversion,
JS7-2/4 is instantly acting 1 conversion delay 1 conversion
Scope of delay: 30s, 60s, 120s, 180s
DS Series Time Relay
Confirms to: GB14048.5
Rated insulation voltage: 380V
Rated voltage: up to 380V, DC 250V
www.peopleelectric.com 036
DL, DY Series Current Voltage Relay
Setting scope of DL (A): 0.0025~0.01, 0.01~0.04 0.0125~0.05, 0.05~0.2 0.15~0.6, 0.5~2, 1.5~6 2.5~10, 5~20, 12.5~50
Voltage setting scope of DY (Y): 15~60, 12~48 40~160, 50~200 80~320, 100~400
JL12 Series Current Relay
Confirms to: GB14048.5
Rated voltage: 380V
Rated current of coil: 5A~300A
JL14 Series Current Relay
Confirms to: GB14048.5
Rated voltage: AC380V, DC220V
Rated current of coil: 1A~600A
JL15 Series Current Relay
Confirms to: GB14048.5
Rated voltage: AC380V, DC440V
Rated current of coil: 1A~600A
JL18 Series Current Relay
Confirms to: GB14048.5
Rated voltage: AC380V, DC440V
Rated current of coil: 1A~630A
DX Series Signal Relay
Rated voltage: 12V, 24V, 48V, 110V, 220V
Rated current: 0.01A~4A
HH52P, 53P, 54P Series General Relay
Confirms to: GB14048.5, IEC61810-1
Rated insulation voltage: 380V
Voltage of coil: up to AC 380V, DC 220V
Group no. of contacts: HH52P has 2 groups of contacts HH53P has 3 groups of contacts HH54P has 4 groups of contacts
Control voltage of coil: AC 6V~380V DC 6V~220V
JQX Series General Relay
Confirms to: GB14048.5, IEC61810-1
Rated operating voltage: AC 220V, 380V, DC220V
Voltage of coil: up to AC380V, DC220V
Group no. of contacts: 2Z is 2 groups of contacts, 3Z is 3 groups of contacts
Control voltage of coil: AC6V~380V DC6V~220V
Control Components
037 www.peopleelectric.com
JTX Series General Relay JQX-13F Series General Relay
RDSJ Series Ultra-Thin Relay RDJ Series Ultra-Thin Relay
SSR Series Solid State Relay GJ Series Solid State Relay
JYB Series Liquid-Level Relay KG316T, KG316TX Series Time-Controlled Switch
Confirms to: GB14048.5, IEC61810-1
Rated operating voltage: AC220V, 380V, DC220V
Group no. of contacts: 2C is 2 groups of contacts 3C is 3 groups of contacts
Control voltage of coil: AC6V~380V DC6V~220V
Confirms to: GB14048.5, IEC61810-1
Rated operating voltage: AC220V, 380V, DC220V
Group no. of contacts: 2 groups of contacts
Control voltage of coil: AC6V~380V DC6V~220V
Confirms to: GB14048.5
Control voltage: AC12V~230V, DC12V~230V
Rated current: 6A
Confirms to: GB14048.5
Control voltage: DC12V~60V
Rated current: 6A
Control voltage: DC3~32V
Operating current: (ordinary type) 1A~40A (enhanced type) 4A~320A
Operating voltage: AC 220V/380V
Control voltage: DC3~32V
Operating current: (ordinary type) 5A~40A (industrial type) 40A~1000A
Operating voltage: AC 220V~380V
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 36V, 110V, 220V 380V 50/60Hz
Operating mode: JYB-2 displacement type, JYB-3, JYB-4 water supply type
Quantity of contacts: 1 group of conversion
Capacity of contacts: AC 250V 10A (resistance)
Confirms to: GB14048.5
Rated operating voltage: AC110~240V 50/60Hz
Form of contacts: delay 1 conversion
Form of acting: timing of action
Scope of delay: 1min~168h
KG16A Series Time-Controlled Switch
Confirms to: GB14048.5
Rated operating voltage: AC110~240V 50/60Hz
Form of contacts: delay 1 conversion
Form of acting: timing of action
Scope of delay: 1min~168h
KG10 Series Time-Controlled Switch
Confirms to: GB14048.5
Rated operating voltage: AC110~240V 50/60Hz
Form of contacts: delay 1 conversion
Form of acting: timing of action
Scope of delay: 1min~168h
KG10YG Series Time-Controlled Switch
Confirms to: GB14048.5
Rated operating voltage: AC110~240V 50/60Hz
Form of contacts: delay 1 conversion
Form of acting: timing of action
Scope of delay: 1min~168h
GUK Series Road lamp Light-Controlled Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC220V 50Hz
Light control device: light sensitive resistor
Rated load: GUK-81:10A, GUK-82:40A,
GUK-83:60A, GUK-84:100A
KG-2 (GUK-2) Series Street Lamp Light-controlled Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC220V 50Hz
Light control device: light-sensitive dioder
Rated load: AC250V 3A
KG20L Series Full-automatic Bell Instrument
Confirms to: GB14048.5
Rated operating voltage: AC110~24V 50/60Hz
Form of contacts: delay 1 conversion
Form of acting: timing of action
Belling frequency within 24h: 20 times
Time of belling: 1min~168h
RDJ1-48 (DH48J) Series Counter
Confirms to: GB14048.5
Rated operating voltage: AC 12~380V 50/60Hz DC12~24V
Form of contacts: 1 conversion
Form of acting: contacts, impact, photoelectric counting
Counting range: 1~9999 (1*10*100)
RDJ1-14 (DH14J) Series Counter
Confirms to: GB14048.5
Rated operating voltage: AC 12~380V 50/60Hz DC12~24V
Form of contacts: 1 conversion
Form of acting: contacts, impact, photoelectric counting
Counting range: 1~9999 (1*10*100)
www.peopleelectric.com 038
Control Components
037 www.peopleelectric.com
JTX Series General Relay JQX-13F Series General Relay
RDSJ Series Ultra-Thin Relay RDJ Series Ultra-Thin Relay
SSR Series Solid State Relay GJ Series Solid State Relay
JYB Series Liquid-Level Relay KG316T, KG316TX Series Time-Controlled Switch
Confirms to: GB14048.5, IEC61810-1
Rated operating voltage: AC220V, 380V, DC220V
Group no. of contacts: 2C is 2 groups of contacts 3C is 3 groups of contacts
Control voltage of coil: AC6V~380V DC6V~220V
Confirms to: GB14048.5, IEC61810-1
Rated operating voltage: AC220V, 380V, DC220V
Group no. of contacts: 2 groups of contacts
Control voltage of coil: AC6V~380V DC6V~220V
Confirms to: GB14048.5
Control voltage: AC12V~230V, DC12V~230V
Rated current: 6A
Confirms to: GB14048.5
Control voltage: DC12V~60V
Rated current: 6A
Control voltage: DC3~32V
Operating current: (ordinary type) 1A~40A (enhanced type) 4A~320A
Operating voltage: AC 220V/380V
Control voltage: DC3~32V
Operating current: (ordinary type) 5A~40A (industrial type) 40A~1000A
Operating voltage: AC 220V~380V
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 36V, 110V, 220V 380V 50/60Hz
Operating mode: JYB-2 displacement type, JYB-3, JYB-4 water supply type
Quantity of contacts: 1 group of conversion
Capacity of contacts: AC 250V 10A (resistance)
Confirms to: GB14048.5
Rated operating voltage: AC110~240V 50/60Hz
Form of contacts: delay 1 conversion
Form of acting: timing of action
Scope of delay: 1min~168h
KG16A Series Time-Controlled Switch
Confirms to: GB14048.5
Rated operating voltage: AC110~240V 50/60Hz
Form of contacts: delay 1 conversion
Form of acting: timing of action
Scope of delay: 1min~168h
KG10 Series Time-Controlled Switch
Confirms to: GB14048.5
Rated operating voltage: AC110~240V 50/60Hz
Form of contacts: delay 1 conversion
Form of acting: timing of action
Scope of delay: 1min~168h
KG10YG Series Time-Controlled Switch
Confirms to: GB14048.5
Rated operating voltage: AC110~240V 50/60Hz
Form of contacts: delay 1 conversion
Form of acting: timing of action
Scope of delay: 1min~168h
GUK Series Road lamp Light-Controlled Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC220V 50Hz
Light control device: light sensitive resistor
Rated load: GUK-81:10A, GUK-82:40A,
GUK-83:60A, GUK-84:100A
KG-2 (GUK-2) Series Street Lamp Light-controlled Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC220V 50Hz
Light control device: light-sensitive dioder
Rated load: AC250V 3A
KG20L Series Full-automatic Bell Instrument
Confirms to: GB14048.5
Rated operating voltage: AC110~24V 50/60Hz
Form of contacts: delay 1 conversion
Form of acting: timing of action
Belling frequency within 24h: 20 times
Time of belling: 1min~168h
RDJ1-48 (DH48J) Series Counter
Confirms to: GB14048.5
Rated operating voltage: AC 12~380V 50/60Hz DC12~24V
Form of contacts: 1 conversion
Form of acting: contacts, impact, photoelectric counting
Counting range: 1~9999 (1*10*100)
RDJ1-14 (DH14J) Series Counter
Confirms to: GB14048.5
Rated operating voltage: AC 12~380V 50/60Hz DC12~24V
Form of contacts: 1 conversion
Form of acting: contacts, impact, photoelectric counting
Counting range: 1~9999 (1*10*100)
www.peopleelectric.com 038
Control Components
039 www.peopleelectric.com
RDJ1-12 Series Counter
Confirms to: GB14048.5
Rated operating voltage: AC 12~380V 50/60Hz DC12~24V
Form of contacts: 1 conversion
Form of acting: contacts, impact, photoelectric counting
Counting range: 1~9999
RDJ1-9 (JDM9) Series Counter
Confirms to: GB14048.5
Rated operating voltage: AC 12~380V 50/60Hz DC12~24V
Form of contacts: 1 conversion
Form of acting: contacts, impact, photoelectric counting
Counting range: 1~9999
RDJ1-3 (JDM3) Series Counter
Confirms to: GB14048.5
Rated operating voltage: AC 12~380V 50/60Hz DC12~24V
Form of contacts: 1 conversion
Form of acting: contacts, impact, photoelectric counting
Counting range: 1~9999
RDJ1-3 (JDM3) Series Counter
Confirms to: GB14048.5
Rated operating voltage: AC 12~380V 50/60Hz DC12~24V
Form of contacts: 1 conversion
Form of acting: contacts, impact, photoelectric counting
Counting range: 1~9999
RDL-3 (SC3L) Series Time-Accumulator
RDL1-48 (DH48L) Series Time-Accumulator
RDJ-3, RDJX-3S Series Over-Voltageand Under-Voltage Protection Auto-Controller
RDJX-2 Series Electronic Load-LimitAuto-Controller
Confirms to: GB14048.5
Timing range: 1s~9999d23h
Confirms to: GB14048.5
Rated operating voltage: AC12~380V 50/60Hz DC12~24V
Timing range: 1s~9999.9h
Rated operating voltage: AC 220V 50/60Hz
Over-voltage protection value: 265V±5V
Under-voltage protection value: 170V±5V
Rated load: 20A, 32A, 40A, 63A
Rated operating voltage: AC 220V 50/60Hz
Over-current protection value: 1A, 3A, 5A, 10A, 15A, 20A, 32A, 40A
www.peopleelectric.com 040
LX3 Series Limit Switch LX5 Series Limit Switch
LX8 Series Limit Switch LX10 Series Limit Switch
LX19 Series Limit Switch LX22 Series Limit Switch
LX44 Series Limit Switch LXP1 Series Limit Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Rated operating current: AC 0.79A, DC 0.15A
Setting thermal current: 5A
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V
Rated operating current: AC 0.26A
Setting thermal current: 3A
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Rated operating current: AC 2.63A, DC 0.91A
Setting thermal current: 20A
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Rated operating current: AC 0.79A, DC 0.91A
Setting thermal current: 10A
It can be with the sealing function, and satisfying
the waterproof requirements
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Rated operating current: AC 0.79A, DC 0.1A
Setting thermal current: 5A
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Rated operating current: AC 20A, DC 0.2A
Setting thermal current: 20A
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V
Setting thermal current: 10A, 20A, 40A
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Rated operating current: AC 5A, DC 0.15A
Setting thermal current: 10A
Control Components
039 www.peopleelectric.com
RDJ1-12 Series Counter
Confirms to: GB14048.5
Rated operating voltage: AC 12~380V 50/60Hz DC12~24V
Form of contacts: 1 conversion
Form of acting: contacts, impact, photoelectric counting
Counting range: 1~9999
RDJ1-9 (JDM9) Series Counter
Confirms to: GB14048.5
Rated operating voltage: AC 12~380V 50/60Hz DC12~24V
Form of contacts: 1 conversion
Form of acting: contacts, impact, photoelectric counting
Counting range: 1~9999
RDJ1-3 (JDM3) Series Counter
Confirms to: GB14048.5
Rated operating voltage: AC 12~380V 50/60Hz DC12~24V
Form of contacts: 1 conversion
Form of acting: contacts, impact, photoelectric counting
Counting range: 1~9999
RDJ1-3 (JDM3) Series Counter
Confirms to: GB14048.5
Rated operating voltage: AC 12~380V 50/60Hz DC12~24V
Form of contacts: 1 conversion
Form of acting: contacts, impact, photoelectric counting
Counting range: 1~9999
RDL-3 (SC3L) Series Time-Accumulator
RDL1-48 (DH48L) Series Time-Accumulator
RDJ-3, RDJX-3S Series Over-Voltageand Under-Voltage Protection Auto-Controller
RDJX-2 Series Electronic Load-LimitAuto-Controller
Confirms to: GB14048.5
Timing range: 1s~9999d23h
Confirms to: GB14048.5
Rated operating voltage: AC12~380V 50/60Hz DC12~24V
Timing range: 1s~9999.9h
Rated operating voltage: AC 220V 50/60Hz
Over-voltage protection value: 265V±5V
Under-voltage protection value: 170V±5V
Rated load: 20A, 32A, 40A, 63A
Rated operating voltage: AC 220V 50/60Hz
Over-current protection value: 1A, 3A, 5A, 10A, 15A, 20A, 32A, 40A
www.peopleelectric.com 040
LX3 Series Limit Switch LX5 Series Limit Switch
LX8 Series Limit Switch LX10 Series Limit Switch
LX19 Series Limit Switch LX22 Series Limit Switch
LX44 Series Limit Switch LXP1 Series Limit Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Rated operating current: AC 0.79A, DC 0.15A
Setting thermal current: 5A
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V
Rated operating current: AC 0.26A
Setting thermal current: 3A
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Rated operating current: AC 2.63A, DC 0.91A
Setting thermal current: 20A
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Rated operating current: AC 0.79A, DC 0.91A
Setting thermal current: 10A
It can be with the sealing function, and satisfying
the waterproof requirements
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Rated operating current: AC 0.79A, DC 0.1A
Setting thermal current: 5A
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Rated operating current: AC 20A, DC 0.2A
Setting thermal current: 20A
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V
Setting thermal current: 10A, 20A, 40A
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Rated operating current: AC 5A, DC 0.15A
Setting thermal current: 10A
Control Components
041 www.peopleelectric.com
JLXK1 Series Limit Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Rated operating current: AC 5A, DC 0.15A
Setting thermal current: 5A
Structure: single-wheel, double-wheels, direct-
acting without wheels, direct-acting with wheels
X2 Series Limit Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V
Rated operating current: AC 2AIt can control two independent circuit at the sametime.
Structure: drive roller, direct-acting type
JW2 Series Limit Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Rated operating current: AC 3A, DC 0.42A
Setting thermal current: 3A
LXK3 Series Limit Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Rated operating current: AC 5A, DC 0.15A
Setting thermal current: 10A
RDLX18 Series Limit Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Rated operating current: AC 0.8A, DC 0.16A
Setting thermal current: 5A
WL Series Limit Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Rated operating current: AC 0.79A, DC 0.15A
Setting thermal current: 5A
HL Series Limit Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Rated operating current: AC 0.79A, DC 0.15A
Setting thermal current: 5A
GYD20 Series Barometric Switch
Confirms to: GB14048.5
Rated operating voltage: 380V or 220V
Rated operating current: 20A, 16A
It is used for the occasion of barometric auto-control
www.peopleelectric.com 042
CM Series Micro Switch
Confirms to: GB14048.5, IEC60947-5-1
Operation speed: 0.01mm to 1m/swc
Rated frequency: 50/60Hz
Scope of application: it is mainly used for the limit
control limit protection and interlock of the machinery
equipments for the machinery, textile, light industry,
electronic instrument
EKW Series Foot Switch
Confirms to: GB14048.5
Rated operating voltage: 380V
Rated operating power: 300VA
Setting thermal current: 5A
YDT1 Series Foot Switch
Confirms to: GB14048.5
Rated operating voltage: AC 380V, DC 220V
Setting thermal current: 5A
LW5 Series Universal Change-Over Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Setting thermal current: 16A
Strong change-over ability, high operation frequency,
and strong connecting and breaking ability etc.
It is used for the change-over electrics to control
circuit (electromagnetic coil, servo motor etc.)
LW6 Series Universal Change-Over Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Setting thermal current: 5A
Many pole number of contacts, and many transfer
circuit etc., which is used for the controlling and
transferring electric circuit etc. of machinery circuit.
LW8 Series Universal Change-Over Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Setting thermal current: 10A, 20A
Strong change-over ability, high operation frequency,
and strong connecting and breaking ability etc.
It is used for the change-over electrics to control
circuit (electromagnetic coil, servo motor etc.)
LW12 Series Universal Change-Over Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Rated operating current: AC 2.6A, DC 0.27A
High operation frequency, and strong connecting and breaking ability etc.
It is used for the change-over electrics to control servocircuit (electromagnetic coil, motor etc.)
LW26 Series Universal Change-Over Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Setting thermal current: 20A~160A
High operation frequency, and strong connecting and breaking ability etc.
It is used for the change-over electrics to control
circuit (electromagnetic coil, servo motor etc.)
Control Components
041 www.peopleelectric.com
JLXK1 Series Limit Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Rated operating current: AC 5A, DC 0.15A
Setting thermal current: 5A
Structure: single-wheel, double-wheels, direct-
acting without wheels, direct-acting with wheels
X2 Series Limit Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V
Rated operating current: AC 2AIt can control two independent circuit at the sametime.
Structure: drive roller, direct-acting type
JW2 Series Limit Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Rated operating current: AC 3A, DC 0.42A
Setting thermal current: 3A
LXK3 Series Limit Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Rated operating current: AC 5A, DC 0.15A
Setting thermal current: 10A
RDLX18 Series Limit Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Rated operating current: AC 0.8A, DC 0.16A
Setting thermal current: 5A
WL Series Limit Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Rated operating current: AC 0.79A, DC 0.15A
Setting thermal current: 5A
HL Series Limit Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Rated operating current: AC 0.79A, DC 0.15A
Setting thermal current: 5A
GYD20 Series Barometric Switch
Confirms to: GB14048.5
Rated operating voltage: 380V or 220V
Rated operating current: 20A, 16A
It is used for the occasion of barometric auto-control
www.peopleelectric.com 042
CM Series Micro Switch
Confirms to: GB14048.5, IEC60947-5-1
Operation speed: 0.01mm to 1m/swc
Rated frequency: 50/60Hz
Scope of application: it is mainly used for the limit
control limit protection and interlock of the machinery
equipments for the machinery, textile, light industry,
electronic instrument
EKW Series Foot Switch
Confirms to: GB14048.5
Rated operating voltage: 380V
Rated operating power: 300VA
Setting thermal current: 5A
YDT1 Series Foot Switch
Confirms to: GB14048.5
Rated operating voltage: AC 380V, DC 220V
Setting thermal current: 5A
LW5 Series Universal Change-Over Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Setting thermal current: 16A
Strong change-over ability, high operation frequency,
and strong connecting and breaking ability etc.
It is used for the change-over electrics to control
circuit (electromagnetic coil, servo motor etc.)
LW6 Series Universal Change-Over Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Setting thermal current: 5A
Many pole number of contacts, and many transfer
circuit etc., which is used for the controlling and
transferring electric circuit etc. of machinery circuit.
LW8 Series Universal Change-Over Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Setting thermal current: 10A, 20A
Strong change-over ability, high operation frequency,
and strong connecting and breaking ability etc.
It is used for the change-over electrics to control
circuit (electromagnetic coil, servo motor etc.)
LW12 Series Universal Change-Over Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Rated operating current: AC 2.6A, DC 0.27A
High operation frequency, and strong connecting and breaking ability etc.
It is used for the change-over electrics to control servocircuit (electromagnetic coil, motor etc.)
LW26 Series Universal Change-Over Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Setting thermal current: 20A~160A
High operation frequency, and strong connecting and breaking ability etc.
It is used for the change-over electrics to control
circuit (electromagnetic coil, servo motor etc.)
Control Components
043 www.peopleelectric.com
HZ10 Series Combination Switch HY2 Series Reversing Switch
QS Series Reversing Switch QX1-13N Series Reversible Switch
RDA1 Series Pushbutton Switch RDA2 Series Pushbutton Switch
RDA37 Series Pushbutton Switch RDA38 Series Pushbutton Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V DC 220V
Rated operating current: AC 10A~100A DC 10A, 25A, 60A, 100A
It is used for infrequently connecting and breaking
motor’s circuit etc.
Confirms to: GB14048.3
Rated operating voltage: 380V, 220V
Setting thermal current: 15A, 30A, 60A
Rated operating power: 1.8kW~10kW
Confirms to: GB14048.3
Rated operating voltage: up to 500V
Setting thermal current: 15A, 30A, 60A
Rated operating power: 4kW~7.5kW
Confirms to: GB14048.3
Rated operating voltage: 380V
Setting thermal current: 12A, 16A, 40A
Rated operating power: 5.5kW~30kW
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V DC 220V
Setting thermal current: 10A
Hole size of installation board: φ22.3
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 400V DC 230V
Setting thermal current: 10A
Hole size of installation board: φ22.3
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V DC 220V
Setting thermal current: 10A
Hole size of installation board: φ22.3
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V DC 220V
Setting thermal current: 10A
Hole size of installation board: φ22.3
PXB2 Series Pushbutton Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V DC 220V
Setting thermal current: 10A
Hole size of installation board: φ22.3
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V DC 220V
Setting thermal current: 10A
Hole size of installation board: φ30
LA2 Series Pushbutton Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V DC 220V
Setting thermal current: 10A
PXAL Series Pushbutton Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V DC 220V
Setting thermal current: 10A
LA10 Series Pushbutton Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V DC 220V
Setting thermal current: 5A
Hole size of installation board: φ24.5
LA18 Series Pushbutton Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V DC 220V
Setting thermal current: 5A
Hole size of installation board: φ24.5
LA19 Series Pushbutton Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V DC 220V
Setting thermal current: 5A
Simple structure, convenient installation and wiring
Hole size of installation board: φ22.3
LAY3 Series Pushbutton Switch COB Series Pushbutton Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Rated operating current: 2.5A, 0.3A
It is used for the control of crane, electric block, etc.
Mechanical interlock between pushbuttons, such
as up and down, left and right, etc.
www.peopleelectric.com 044
Control Components
043 www.peopleelectric.com
HZ10 Series Combination Switch HY2 Series Reversing Switch
QS Series Reversing Switch QX1-13N Series Reversible Switch
RDA1 Series Pushbutton Switch RDA2 Series Pushbutton Switch
RDA37 Series Pushbutton Switch RDA38 Series Pushbutton Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V DC 220V
Rated operating current: AC 10A~100A DC 10A, 25A, 60A, 100A
It is used for infrequently connecting and breaking
motor’s circuit etc.
Confirms to: GB14048.3
Rated operating voltage: 380V, 220V
Setting thermal current: 15A, 30A, 60A
Rated operating power: 1.8kW~10kW
Confirms to: GB14048.3
Rated operating voltage: up to 500V
Setting thermal current: 15A, 30A, 60A
Rated operating power: 4kW~7.5kW
Confirms to: GB14048.3
Rated operating voltage: 380V
Setting thermal current: 12A, 16A, 40A
Rated operating power: 5.5kW~30kW
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V DC 220V
Setting thermal current: 10A
Hole size of installation board: φ22.3
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 400V DC 230V
Setting thermal current: 10A
Hole size of installation board: φ22.3
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V DC 220V
Setting thermal current: 10A
Hole size of installation board: φ22.3
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V DC 220V
Setting thermal current: 10A
Hole size of installation board: φ22.3
PXB2 Series Pushbutton Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V DC 220V
Setting thermal current: 10A
Hole size of installation board: φ22.3
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V DC 220V
Setting thermal current: 10A
Hole size of installation board: φ30
LA2 Series Pushbutton Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V DC 220V
Setting thermal current: 10A
PXAL Series Pushbutton Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V DC 220V
Setting thermal current: 10A
LA10 Series Pushbutton Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V DC 220V
Setting thermal current: 5A
Hole size of installation board: φ24.5
LA18 Series Pushbutton Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V DC 220V
Setting thermal current: 5A
Hole size of installation board: φ24.5
LA19 Series Pushbutton Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V DC 220V
Setting thermal current: 5A
Simple structure, convenient installation and wiring
Hole size of installation board: φ22.3
LAY3 Series Pushbutton Switch COB Series Pushbutton Switch
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Rated operating current: 2.5A, 0.3A
It is used for the control of crane, electric block, etc.
Mechanical interlock between pushbuttons, such
as up and down, left and right, etc.
www.peopleelectric.com 044
Control Components
045 www.peopleelectric.com
BS Pushbutton Power Switch AD11 Series Signal Lamp
AD16 Series BuzzerAD22 Series Indicator Lamp
JD-5 Series Motor Synthetical Protector
JD-6 Series Motor Synthetical Protector
JD-5E Series Motor Synthetical Protector
JD-8 Series Motor Synthetical Protector
Confirms to: GB14048.5, IEC60947-5-1
Rated voltage: AC 380V
Rated operating current: 4A, 6A, 10A
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Setting thermal current: 10A
Uses LED illuminate, high brightness, low
energy-consumption
Hole size of AD11-22 installation board is φ22.3
Hole size of AD11-25 installation board is φ25.5
Hole size of AD11-30 installation board is φ30.5 Screw type concealed wiring
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: 6V, 12V, 24V, 36V, 48V, 110V, 127V, 220V, 380V
Setting thermal current: 10A
Uses LED illuminate, high brightness, low
energy-consumption
Hole size of AD11-22 installation board is φ22.3
Screw type concealed wiring, plug-type wiring
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: 6V, 12V, 24V, 36V, 48V, 110V, 127V, 220V, 380V
Rated operating current: ≤20mA
Uses LED illuminate, high brightness, low
energy-consumption
Hole size of AD11-22 installation board is φ22.3
Screw type concealed wiring, plug-type wiring
Confirms to: G14048.4
Rated operating voltage: AC 220V/380V
Rated current: 0.5A~100A
Capacity of contacts: 1 group of NC contacts,
AC 220V 5A
Releasing grade: 10A 3P
With over-load and break phase protective
function
Confirms to: G14048.4
Rated operating voltage: AC 220V/380V
Rated current: 0.5A~100A
Capacity of contacts: 1 group of NC contacts,
AC 220V 5A
Releasing grade: 10A 3P
With over-load and break phase protective
function
Confirms to: G14048.4
Rated operating voltage: AC 220V/380V
Rated current: 0.5A~100A
Capacity of contacts: 1 group of NC contacts,
AC 220V 5A
Releasing grade: 10A 3P
With over-load and break phase protective
function
Confirms to: G14048.4
Rated operating voltage: AC 220V/380V
Rated current: 0.5A~60A
Capacity of contacts: 1 group of NC contacts,
AC 220V 5A
Releasing grade: 10A 3P
With over-load and break phase protective
function
www.peopleelectric.com 046
RHQ-S-C Series Motor Synthetical Protector
Confirms to: G14048.4
Rated operating voltage: AC 220V/380V
Rated current: 0.5A~400A
Capacity of contacts: 1 group of NC contacts,
AC 220V 5A
Releasing grade: 10A 3P
With over-load and break phase protective
function
XJ Series Break Phase and Phase-Sequence Protective Controller
Confirms to: G14048.5
Rated operating voltage: AC 380V 50/60Hz
Output of contacts: 1NO, 1NC
Capacity of contacts: AC 250V 5A (Resistance)
XJ01 Series Auto-Coupling ReducedVoltage Starter
Confirms to: GB14048.4
Frame size: 30, 75, 115, 190, 300, 400
Rated power: 14kW~400kW
Rated current: 28A~800A
Operating voltage: 380V/three phase
Suited motor: squirrel-cage three phase AC
asynchronous motor
Installation mode: box type structure floor install
JJ1 Series Auto-Coupling ReducedVoltage Starter
Confirms to: GB14048.4
Frame size: 30, 75, 115, 190, 300, 400
Rated power: 14kW~400kW
Rated current: 28A~800A
Operating voltage: 380V/three phase
Suited motor: squirrel-cage three phase AC
asynchronous motor
Installation mode: box type structure floor install
QX1 Series Star-Delta Starter
Confirms to: GB14048.3
Frame size: 13, 13N, 13
Rated power: 13kW~30kW
Rated frequency: 50/60Hz
Operating voltage: 380V/three phase
QX4 Series Star-Delta Starter
Confirms to: GB14048.4
Frame size: 17, 30, 55, 75
Rated power: 13kW~75kW
Rated current: 28A~85A
Operating voltage: 380V/three phase
Suited motor: squirrel-cage three phase AC
asynchronous motor Installation mode: box type structure floor or
wall type install
QJX2 Series Star-Delta Starter
Confirms to: GB14048.4
Rated operating current: 12A~95A
Rated insulation voltage: 660V
Control voltage of coil: AC 24V/36V/48V/110V/127V/ 220V/380V/440V/660V
RDQ12 Series Electromagnetic Starter
Confirms to: GB14048.4
Rated operating current: 10A~150A
Rated insulation voltage: 380V
Control voltage of coil: AC 24V/36V/48V/110V/127V/ 220V/380V/440V/660V
Control Components
045 www.peopleelectric.com
BS Pushbutton Power Switch AD11 Series Signal Lamp
AD16 Series BuzzerAD22 Series Indicator Lamp
JD-5 Series Motor Synthetical Protector
JD-6 Series Motor Synthetical Protector
JD-5E Series Motor Synthetical Protector
JD-8 Series Motor Synthetical Protector
Confirms to: GB14048.5, IEC60947-5-1
Rated voltage: AC 380V
Rated operating current: 4A, 6A, 10A
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: AC 380V, DC 220V
Setting thermal current: 10A
Uses LED illuminate, high brightness, low
energy-consumption
Hole size of AD11-22 installation board is φ22.3
Hole size of AD11-25 installation board is φ25.5
Hole size of AD11-30 installation board is φ30.5 Screw type concealed wiring
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: 6V, 12V, 24V, 36V, 48V, 110V, 127V, 220V, 380V
Setting thermal current: 10A
Uses LED illuminate, high brightness, low
energy-consumption
Hole size of AD11-22 installation board is φ22.3
Screw type concealed wiring, plug-type wiring
Confirms to: GB14048.5, IEC60947-5-1
Rated operating voltage: 6V, 12V, 24V, 36V, 48V, 110V, 127V, 220V, 380V
Rated operating current: ≤20mA
Uses LED illuminate, high brightness, low
energy-consumption
Hole size of AD11-22 installation board is φ22.3
Screw type concealed wiring, plug-type wiring
Confirms to: G14048.4
Rated operating voltage: AC 220V/380V
Rated current: 0.5A~100A
Capacity of contacts: 1 group of NC contacts,
AC 220V 5A
Releasing grade: 10A 3P
With over-load and break phase protective
function
Confirms to: G14048.4
Rated operating voltage: AC 220V/380V
Rated current: 0.5A~100A
Capacity of contacts: 1 group of NC contacts,
AC 220V 5A
Releasing grade: 10A 3P
With over-load and break phase protective
function
Confirms to: G14048.4
Rated operating voltage: AC 220V/380V
Rated current: 0.5A~100A
Capacity of contacts: 1 group of NC contacts,
AC 220V 5A
Releasing grade: 10A 3P
With over-load and break phase protective
function
Confirms to: G14048.4
Rated operating voltage: AC 220V/380V
Rated current: 0.5A~60A
Capacity of contacts: 1 group of NC contacts,
AC 220V 5A
Releasing grade: 10A 3P
With over-load and break phase protective
function
www.peopleelectric.com 046
RHQ-S-C Series Motor Synthetical Protector
Confirms to: G14048.4
Rated operating voltage: AC 220V/380V
Rated current: 0.5A~400A
Capacity of contacts: 1 group of NC contacts,
AC 220V 5A
Releasing grade: 10A 3P
With over-load and break phase protective
function
XJ Series Break Phase and Phase-Sequence Protective Controller
Confirms to: G14048.5
Rated operating voltage: AC 380V 50/60Hz
Output of contacts: 1NO, 1NC
Capacity of contacts: AC 250V 5A (Resistance)
XJ01 Series Auto-Coupling ReducedVoltage Starter
Confirms to: GB14048.4
Frame size: 30, 75, 115, 190, 300, 400
Rated power: 14kW~400kW
Rated current: 28A~800A
Operating voltage: 380V/three phase
Suited motor: squirrel-cage three phase AC
asynchronous motor
Installation mode: box type structure floor install
JJ1 Series Auto-Coupling ReducedVoltage Starter
Confirms to: GB14048.4
Frame size: 30, 75, 115, 190, 300, 400
Rated power: 14kW~400kW
Rated current: 28A~800A
Operating voltage: 380V/three phase
Suited motor: squirrel-cage three phase AC
asynchronous motor
Installation mode: box type structure floor install
QX1 Series Star-Delta Starter
Confirms to: GB14048.3
Frame size: 13, 13N, 13
Rated power: 13kW~30kW
Rated frequency: 50/60Hz
Operating voltage: 380V/three phase
QX4 Series Star-Delta Starter
Confirms to: GB14048.4
Frame size: 17, 30, 55, 75
Rated power: 13kW~75kW
Rated current: 28A~85A
Operating voltage: 380V/three phase
Suited motor: squirrel-cage three phase AC
asynchronous motor Installation mode: box type structure floor or
wall type install
QJX2 Series Star-Delta Starter
Confirms to: GB14048.4
Rated operating current: 12A~95A
Rated insulation voltage: 660V
Control voltage of coil: AC 24V/36V/48V/110V/127V/ 220V/380V/440V/660V
RDQ12 Series Electromagnetic Starter
Confirms to: GB14048.4
Rated operating current: 10A~150A
Rated insulation voltage: 380V
Control voltage of coil: AC 24V/36V/48V/110V/127V/ 220V/380V/440V/660V
Control Components
047 www.peopleelectric.com
RDQ20 Series Electromagnetic Starter
Confirms to: GB14048.4
Rated operating current: 10A~150A
Rated insulation voltage: 380V
Control voltage of coil: AC 24V/36V/48V/110V/127V/ 220V/380V
QCX5 Series Electromagnetic Starter
Confirms to: GB14048.4
Rated operating current: 9A~40A
Rated insulation voltage: 660V
Control voltage of coil: AC 24V/36V/48V/110V/127V/ 220V/380V/440V/660V
QCX8 Series Electromagnetic Starter
Confirms to: GB14048.4
Rated operating current: 9A~85A
Rated insulation voltage: 660V
Control voltage of coil: AC 24V/36V/48V/110V/127V/ 220V/380V/440V/660V
QZ610 Series Motor Protector
Confirms to: GB14048.4
Rated operating current: 10A~40A
Rated voltage: AC380V
RDB7 Series Variable Frequency Device
Confirms to: GB12668.2
Rated voltage: single phase 220V, three phase 380V
Power of motor: 0.75kW~315kW
Installation mode: wall type and cabinet type
RDI67 Series Variable Frequency Device
Confirms to: GB12668.2
Rated voltage: single phase 220V, three phase 380V
Power of motor: 0.75kW~315kW
RDJR6 Series Soft Starter
Confirms to: GB14048.6
Frame size: 75, 200, 315, 450
Rated power: 5.5kW~450kW
Rated current: 22A~900A
Operating voltage: 400V/three phase
Suited motor: squirrel-cage three phase AC
asynchronous motor
Installation mode: wall type installation
RDRQ1 Series Soft Starter
Confirms to: GB14048.6
Frame size: 37, 75, 200, 315, 450
Rated power: 11kW~450kW
Rated current: 22A~900A
Operating voltage: 400V/three phase
Suited motor: squirrel-cage three phase AC
asynchronous motor
Installation mode: wall type installation
www.peopleelectric.com 048
XJ01E Series Soft Starter ControlCabinet
Confirms to: GB14048.6
Frame size: 40, 75, 200, 315, 450
Rated power: 14kW~450kW
Rated current: 28A~1000A
Operating voltage: 400V/three phase
Suited motor: squirrel-cage three phase AC
asynchronous motor
Installation mode: cabinet type structure floor
installation
JD Series Electronic Speed Regulating Device
JD6A Series Electronic SpeedRegulating Device
KT10 Series Cam Controller
KT12 Series Cam Controller KT14 Series Cam Controller
KTJ6 Series Cam ControllerKTJ1 Series Cam Controller
Rated operating voltage: AC 220V
Rated output current: DC 90V 3.15A/5A/5A/8A
Controllable motor power: 0.55kW~90kW
Suited motor is electromagnetic speed-
regulating motor
Rated operating voltage: AC 220V
Rated output current: DC 90V 3.15A/5A/5A/8A
Controllable motor power: 0.55kW~90kW
Suited motor is electromagnetic speed-
regulating motor
Rated voltage: AC 380V
Rated frequency: 50/60Hz
Rated current: 25A, 60A
Operation frequency: 600 times/h
Mechanical life: 1.5 *10 times
Rated voltage: AC 380V
Rated frequency: 50/60Hz
Rated current: 25A, 60A
Operation frequency: 600 times/h
Rated voltage: AC 380V
Rated frequency: 50/60Hz
Rated current: 25A, 60A
Operation frequency: 600 times/h
Mechanical life: 1.5 *10 times
Rated voltage: AC 380V
Rated frequency: 50/60Hz
Rated current: 50A, 80A
Operation frequency: 600 times/h
Rated voltage: AC 380V
Rated frequency: 50/60Hz
Rated current: 25A, 60A
Control Components
047 www.peopleelectric.com
RDQ20 Series Electromagnetic Starter
Confirms to: GB14048.4
Rated operating current: 10A~150A
Rated insulation voltage: 380V
Control voltage of coil: AC 24V/36V/48V/110V/127V/ 220V/380V
QCX5 Series Electromagnetic Starter
Confirms to: GB14048.4
Rated operating current: 9A~40A
Rated insulation voltage: 660V
Control voltage of coil: AC 24V/36V/48V/110V/127V/ 220V/380V/440V/660V
QCX8 Series Electromagnetic Starter
Confirms to: GB14048.4
Rated operating current: 9A~85A
Rated insulation voltage: 660V
Control voltage of coil: AC 24V/36V/48V/110V/127V/ 220V/380V/440V/660V
QZ610 Series Motor Protector
Confirms to: GB14048.4
Rated operating current: 10A~40A
Rated voltage: AC380V
RDB7 Series Variable Frequency Device
Confirms to: GB12668.2
Rated voltage: single phase 220V, three phase 380V
Power of motor: 0.75kW~315kW
Installation mode: wall type and cabinet type
RDI67 Series Variable Frequency Device
Confirms to: GB12668.2
Rated voltage: single phase 220V, three phase 380V
Power of motor: 0.75kW~315kW
RDJR6 Series Soft Starter
Confirms to: GB14048.6
Frame size: 75, 200, 315, 450
Rated power: 5.5kW~450kW
Rated current: 22A~900A
Operating voltage: 400V/three phase
Suited motor: squirrel-cage three phase AC
asynchronous motor
Installation mode: wall type installation
RDRQ1 Series Soft Starter
Confirms to: GB14048.6
Frame size: 37, 75, 200, 315, 450
Rated power: 11kW~450kW
Rated current: 22A~900A
Operating voltage: 400V/three phase
Suited motor: squirrel-cage three phase AC
asynchronous motor
Installation mode: wall type installation
www.peopleelectric.com 048
XJ01E Series Soft Starter ControlCabinet
Confirms to: GB14048.6
Frame size: 40, 75, 200, 315, 450
Rated power: 14kW~450kW
Rated current: 28A~1000A
Operating voltage: 400V/three phase
Suited motor: squirrel-cage three phase AC
asynchronous motor
Installation mode: cabinet type structure floor
installation
JD Series Electronic Speed Regulating Device
JD6A Series Electronic SpeedRegulating Device
KT10 Series Cam Controller
KT12 Series Cam Controller KT14 Series Cam Controller
KTJ6 Series Cam ControllerKTJ1 Series Cam Controller
Rated operating voltage: AC 220V
Rated output current: DC 90V 3.15A/5A/5A/8A
Controllable motor power: 0.55kW~90kW
Suited motor is electromagnetic speed-
regulating motor
Rated operating voltage: AC 220V
Rated output current: DC 90V 3.15A/5A/5A/8A
Controllable motor power: 0.55kW~90kW
Suited motor is electromagnetic speed-
regulating motor
Rated voltage: AC 380V
Rated frequency: 50/60Hz
Rated current: 25A, 60A
Operation frequency: 600 times/h
Mechanical life: 1.5 *10 times
Rated voltage: AC 380V
Rated frequency: 50/60Hz
Rated current: 25A, 60A
Operation frequency: 600 times/h
Rated voltage: AC 380V
Rated frequency: 50/60Hz
Rated current: 25A, 60A
Operation frequency: 600 times/h
Mechanical life: 1.5 *10 times
Rated voltage: AC 380V
Rated frequency: 50/60Hz
Rated current: 50A, 80A
Operation frequency: 600 times/h
Rated voltage: AC 380V
Rated frequency: 50/60Hz
Rated current: 25A, 60A
Control Components
049 www.peopleelectric.com
KTJ15 Series Cam Controller
Rated voltage: AC 380V
Rated frequency: 50/60Hz
Rated current: 32A, 63A
Mechanical life: 3 *10 times
LK1 Series Cam Controller
Rated voltage: AC 380V
Rated frequency: 50/60Hz
Rated current: 10A
LK4 Series Cam Controller
Rated voltage: AC 380V, DC440V
Rated frequency: 50/60Hz
Rated current: 10A
Operation frequency: 1200 times/h
LK5 Series Cam Controller
Rated voltage: AC 380V, DC440V
Rated frequency: 50/60Hz
Rated current: 10A
RDCPS Series Control and ProtectiveSwitch
Confirms to: GB14048.9
Frame size: 45, 125A
Rated operating current: 0.4A~125A
Rated insulation voltage: 690V
Control voltage of coil: AC 220V/380V
Number of pole: 3P, 4P
RDCPSD Series Double SpeedController
Confirms to: GB14048.9
Rated operating current: 0.4A~125A
Rated insulation voltage: 690V
Control voltage of coil: AC 220V/380V
Number of pole: 3P
RDCPSJ Series Star-Delta Controller
Confirms to: GB14048.9
Rated operating current: 0.4A~125A
Rated insulation voltage: 690V
Control voltage of coil: AC 220V/380V
Number of pole: 3P
Control Components