CJT1 Series AC Contactor CJ12 Series AC Contactor

CJC20 Series AC ContactorCJ20 Series AC Contactor

CJ40 Series AC Contactor CJX1 Series AC Contactor

CJX2 Series AC Contactor CJX5 Series AC Contactor

Confirms to: GB14048.4, IEC60947-4-1

Rated operating current: 5A~150A

Rated operating voltage: 380V

Number of pole: 3P

Control voltage of coil: AC24V/36V/48V/110V/

127V/220V/380V

Combination of auxiliary contacts group: 2NO2NC

www.peopleelectric.com 030

Confirms to: GB14048.4, IEC60947-4-1

Rated operating current: 100A~630A

Rated operating voltage: 380V

Number of pole: 2P, 3P, 4P, 5P

Control voltage of coil: AC24V/36V/48V/110V/

127V/220V/380V

Combination of auxiliary contacts group: 3NO3NC

Confirms to: GB14048.4, IEC60947-4-1

Rated operating current: 10A~630A

Rated operating voltage: 220V, 380V, 660V

Number of pole: 3P

Control voltage of coil: AC24V/36V/48V/110V/

127V/220V/380V/440V/660V

Combination of auxiliary contacts group:

2NO2NC (10~160A), 3NO3NC (250A~630A)

Confirms to: GB14048.4, IEC60947-4-1

Rated operating current: 63A~630A

Rated operating voltage: 220V, 380V, 660V

Number of pole: 3P

Control voltage of coil: AC24V/36V/48V/110V/

127V/220V/380V/440V/660V

Combination of auxiliary contacts group:

1NO1NC (63~160A), 2NO2NC (250A~630A)

Confirms to: GB14048.4, IEC60947-4-1

Rated operating current: 10A~1000A

Rated operating voltage: 220V, 380V, 660V

Number of pole: 3P

Control voltage of coil: AC24V/36V/48V/110V/

127V/220V/380V/440V/660V

Combination of auxiliary contacts group:

2NO2NC (10~250A), 3NO3NC (315A~1000A)

Confirms to: GB14048.4, IEC60947-4-1

Rated operating current: 9A~400A

Rated operating voltage: 220V, 380V, 660V

Number of pole: 3P

Control voltage of coil: AC24V/36V/48V/110V/

127V/220V/380V/440V/660V

Combination of auxiliary contacts group: 2NO2NC

Confirms to: GB14048.4, IEC60947-4-1

Rated operating current: 9A~630A

Rated operating voltage: 220V, 380V, 660V

Number of pole: 3P

Control voltage of coil: AC24V/36V/48V/110V/

127V/220V/380V/440V/660V

Confirms to: GB14048.4, IEC60947-4-1

Rated operating current: 9A~105A

Rated operating voltage: 220V, 380V, 660V

Number of pole: 3P

Control voltage of coil: AC24V/36V/48V/110V/

127V/220V/380V/440V/660V

Page 2: 6-Control Components

Control Components

CJT1 Series AC Contactor CJ12 Series AC Contactor

CJC20 Series AC ContactorCJ20 Series AC Contactor

CJ40 Series AC Contactor CJX1 Series AC Contactor

CJX2 Series AC Contactor CJX5 Series AC Contactor

Confirms to: GB14048.4, IEC60947-4-1

Rated operating current: 5A~150A

Rated operating voltage: 380V

Number of pole: 3P

Control voltage of coil: AC24V/36V/48V/110V/

127V/220V/380V

Combination of auxiliary contacts group: 2NO2NC

www.peopleelectric.com 030

Confirms to: GB14048.4, IEC60947-4-1

Rated operating current: 100A~630A

Rated operating voltage: 380V

Number of pole: 2P, 3P, 4P, 5P

Control voltage of coil: AC24V/36V/48V/110V/

127V/220V/380V

Combination of auxiliary contacts group: 3NO3NC

Confirms to: GB14048.4, IEC60947-4-1

Rated operating current: 10A~630A

Rated operating voltage: 220V, 380V, 660V

Number of pole: 3P

Control voltage of coil: AC24V/36V/48V/110V/

127V/220V/380V/440V/660V

Combination of auxiliary contacts group:

2NO2NC (10~160A), 3NO3NC (250A~630A)

Confirms to: GB14048.4, IEC60947-4-1

Rated operating current: 63A~630A

Rated operating voltage: 220V, 380V, 660V

Number of pole: 3P

Control voltage of coil: AC24V/36V/48V/110V/

127V/220V/380V/440V/660V

Combination of auxiliary contacts group:

1NO1NC (63~160A), 2NO2NC (250A~630A)

Confirms to: GB14048.4, IEC60947-4-1

Rated operating current: 10A~1000A

Rated operating voltage: 220V, 380V, 660V

Number of pole: 3P

Control voltage of coil: AC24V/36V/48V/110V/

127V/220V/380V/440V/660V

Combination of auxiliary contacts group:

2NO2NC (10~250A), 3NO3NC (315A~1000A)

Confirms to: GB14048.4, IEC60947-4-1

Rated operating current: 9A~400A

Rated operating voltage: 220V, 380V, 660V

Number of pole: 3P

Control voltage of coil: AC24V/36V/48V/110V/

127V/220V/380V/440V/660V

Combination of auxiliary contacts group: 2NO2NC

Confirms to: GB14048.4, IEC60947-4-1

Rated operating current: 9A~630A

Rated operating voltage: 220V, 380V, 660V

Number of pole: 3P

Control voltage of coil: AC24V/36V/48V/110V/

127V/220V/380V/440V/660V

Confirms to: GB14048.4, IEC60947-4-1

Rated operating current: 9A~105A

Rated operating voltage: 220V, 380V, 660V

Number of pole: 3P

Control voltage of coil: AC24V/36V/48V/110V/

127V/220V/380V/440V/660V

Page 3: 6-Control Components

031 www.peopleelectric.com

Confirms to: GB14048.4, IEC60947-4-1

Rated operating current: 9A~370A

Rated operating voltage: 220V, 380V, 660V

Number of pole: 3P

Control voltage of coil: AC24V/36V/48V/110V/

127V/220V/380V/440V/660V

CJX8 Series AC Contactor RDC30 Series AC Contactor

RDC6 Series AC Contactor CJX2-Z Series DC Operated Contactor

Confirms to: GB14048.4, IEC60947-4-1

Rated operating current: 9A~80A

Rated operating voltage: 220V, 380V, 660V

Number of pole: 3P

Control voltage of coil: AC24V/36V/48V/110V/

127V/220V/380V/440V/660V

Confirms to: GB14048.4, IEC60947-4-1

Rated operating current: 9A~95A

Rated operating voltage: 220V, 380V, 660V

Number of pole: 3P

Control voltage of coil: AC24V/36V/48V/110V/

127V/220V/380V/440V/660V

Confirms to: GB14048.4, IEC60947-4-1

Rated operating current: 9A~95A

Rated operating voltage: 220V, 380V, 660V

Number of pole: 3P

Control voltage of coil: DC24V/36V/48V/110V/

127V/230V

RDZJ Series DC Contactor CJX8-C Series Switching Capacitor Contactor

RDC19 Series Switching Capacitor Contactor

RDC19B Series Switching Capacitor Contactor

Confirms to: GB14048.4

Rated operating current: 50A~600A

Control voltage of coil:DC12V/24V/36V/40V/48V/60VConfirms to: GB14048.4

Setting thermal current: 32A~85A

When AC-6b, 380V, controllable capacitor ’s capacity:

15~50kvar

Rated insulation voltage: 500V

Rated operating voltage: 380V

Number of pole: 3P

Control voltage of coil: AC 24V/36V/48V/110V/127V/

220V/380V/440V

Confirms to: GB14048.4

Setting thermal current: 25A~43A

When AC-6b, 380V, controllable capacitor ’s capacity:

12~20kvar

Rated insulation voltage: 660V

Rated operating voltage: 380V

Number of pole: 3P

Control voltage of coil: AC 24V/36V/48V/110V/127V/

220V/380V/440V

Confirms to: GB14048.4

Setting thermal current: 25A~108A

When AC-6b, 380V, controllable capacitor ’s capacity:

12~50kvar

Rated insulation voltage: 660V

Rated operating voltage: 380V

Number of pole: 3P

Control voltage of coil: AC 24V/36V/48V/110V/127V/

220V/380V/440V/660

www.peopleelectric.com 032

CKJ5 Series Low Voltage Vacuum Contactor

PGV Series Motor Protection CircuitBreaker

JZC4 Series Intermediate Relay JZC4-Z Series Intermediate Relay

JZ7 Series Intermediate Relay DZ Series Intermediate Relay

JRS1 Series Thermal Overload Relay JRS2 Series Thermal Overload Relay

Confirms to: GB14048.4, IEC60947-4-1

Rated operating current: 80A~630A

Rated insulation voltage: 1140V

Rated operating voltage: 380V

Number of pole: 3P

Confirms to: GB14048.5, IEC60947-5-1

Setting thermal current: 20A

Rated operating voltage: 690V

Combination of auxiliary contacts: 22/31/40

Control voltage of coil: AC 24V/36V/48V/110V/

127V/220V/380V/440V/660

Confirms to: GB14048.5

Setting thermal current: 20A

Rated operating voltage: 690V

Combination of auxiliary contacts: 22/31/40

Control voltage of coil: DC 24V/36V/48V/110V/

127V/230V

, IEC60947-5-1

Confirms to: GB14048.5, IEC60947-5-1

Setting thermal current: 5A

Rated operating voltage: 380V

Combination of auxiliary contacts: 44/53/62/71/80

Control voltage of coil: AC 24V/36V/48V/110V/

127V/220V/380V

Operation mode: “Y” DC voltage operation, “L” DC current

operation, “J” AC voltage operation, “B” with keeping winding

“S” Delay, “K” Fast action

Rated voltage of DZY: DC 12V~220V

Rated current of DZL: DC 0.25A~8A

Rated voltage of DZJ: AC 12V~380V

Rated current of DZB: DC 0.25A~8A

Rated voltage of DZB: DC 12V~220V

Rated voltage of DZS: DC 24V~220V

Rated current of DZK: DC 0.25A~8A

Rated voltage of DZK: DC 24V~220V

Confirms to: IEC60947-4-1

Rated insulation voltage: 690V

Rated operating voltage: 380V

Rated impact withstand voltage: 8kV

Rated current: 0.1A~80A

Auxiliary contacts: 1NO+1NC

Suited contactor: CJX2

Confirms to: IEC60947-4-1

Rated insulation voltage: 690V

Rated operating voltage: 690V

Rated current: 0.1A~630A

Auxiliary contacts: 1NO+1NC

Suited contactor: CJX1

Confirms to: IEC60947-2, IEC60947-4-1

Setting Range: 0.1~80A

Rated operating voltage: 690V

Rated frequency: 50/60Hz

Control Components

Page 4: 6-Control Components

031 www.peopleelectric.com

Confirms to: GB14048.4, IEC60947-4-1

Rated operating current: 9A~370A

Rated operating voltage: 220V, 380V, 660V

Number of pole: 3P

Control voltage of coil: AC24V/36V/48V/110V/

127V/220V/380V/440V/660V

CJX8 Series AC Contactor RDC30 Series AC Contactor

RDC6 Series AC Contactor CJX2-Z Series DC Operated Contactor

Confirms to: GB14048.4, IEC60947-4-1

Rated operating current: 9A~80A

Rated operating voltage: 220V, 380V, 660V

Number of pole: 3P

Control voltage of coil: AC24V/36V/48V/110V/

127V/220V/380V/440V/660V

Confirms to: GB14048.4, IEC60947-4-1

Rated operating current: 9A~95A

Rated operating voltage: 220V, 380V, 660V

Number of pole: 3P

Control voltage of coil: AC24V/36V/48V/110V/

127V/220V/380V/440V/660V

Confirms to: GB14048.4, IEC60947-4-1

Rated operating current: 9A~95A

Rated operating voltage: 220V, 380V, 660V

Number of pole: 3P

Control voltage of coil: DC24V/36V/48V/110V/

127V/230V

RDZJ Series DC Contactor CJX8-C Series Switching Capacitor Contactor

RDC19 Series Switching Capacitor Contactor

RDC19B Series Switching Capacitor Contactor

Confirms to: GB14048.4

Rated operating current: 50A~600A

Control voltage of coil:DC12V/24V/36V/40V/48V/60VConfirms to: GB14048.4

Setting thermal current: 32A~85A

When AC-6b, 380V, controllable capacitor ’s capacity:

15~50kvar

Rated insulation voltage: 500V

Rated operating voltage: 380V

Number of pole: 3P

Control voltage of coil: AC 24V/36V/48V/110V/127V/

220V/380V/440V

Confirms to: GB14048.4

Setting thermal current: 25A~43A

When AC-6b, 380V, controllable capacitor ’s capacity:

12~20kvar

Rated insulation voltage: 660V

Rated operating voltage: 380V

Number of pole: 3P

Control voltage of coil: AC 24V/36V/48V/110V/127V/

220V/380V/440V

Confirms to: GB14048.4

Setting thermal current: 25A~108A

When AC-6b, 380V, controllable capacitor ’s capacity:

12~50kvar

Rated insulation voltage: 660V

Rated operating voltage: 380V

Number of pole: 3P

Control voltage of coil: AC 24V/36V/48V/110V/127V/

220V/380V/440V/660

www.peopleelectric.com 032

CKJ5 Series Low Voltage Vacuum Contactor

PGV Series Motor Protection CircuitBreaker

JZC4 Series Intermediate Relay JZC4-Z Series Intermediate Relay

JZ7 Series Intermediate Relay DZ Series Intermediate Relay

JRS1 Series Thermal Overload Relay JRS2 Series Thermal Overload Relay

Confirms to: GB14048.4, IEC60947-4-1

Rated operating current: 80A~630A

Rated insulation voltage: 1140V

Rated operating voltage: 380V

Number of pole: 3P

Confirms to: GB14048.5, IEC60947-5-1

Setting thermal current: 20A

Rated operating voltage: 690V

Combination of auxiliary contacts: 22/31/40

Control voltage of coil: AC 24V/36V/48V/110V/

127V/220V/380V/440V/660

Confirms to: GB14048.5

Setting thermal current: 20A

Rated operating voltage: 690V

Combination of auxiliary contacts: 22/31/40

Control voltage of coil: DC 24V/36V/48V/110V/

127V/230V

, IEC60947-5-1

Confirms to: GB14048.5, IEC60947-5-1

Setting thermal current: 5A

Rated operating voltage: 380V

Combination of auxiliary contacts: 44/53/62/71/80

Control voltage of coil: AC 24V/36V/48V/110V/

127V/220V/380V

Operation mode: “Y” DC voltage operation, “L” DC current

operation, “J” AC voltage operation, “B” with keeping winding

“S” Delay, “K” Fast action

Rated voltage of DZY: DC 12V~220V

Rated current of DZL: DC 0.25A~8A

Rated voltage of DZJ: AC 12V~380V

Rated current of DZB: DC 0.25A~8A

Rated voltage of DZB: DC 12V~220V

Rated voltage of DZS: DC 24V~220V

Rated current of DZK: DC 0.25A~8A

Rated voltage of DZK: DC 24V~220V

Confirms to: IEC60947-4-1

Rated insulation voltage: 690V

Rated operating voltage: 380V

Rated impact withstand voltage: 8kV

Rated current: 0.1A~80A

Auxiliary contacts: 1NO+1NC

Suited contactor: CJX2

Confirms to: IEC60947-4-1

Rated insulation voltage: 690V

Rated operating voltage: 690V

Rated current: 0.1A~630A

Auxiliary contacts: 1NO+1NC

Suited contactor: CJX1

Confirms to: IEC60947-2, IEC60947-4-1

Setting Range: 0.1~80A

Rated operating voltage: 690V

Rated frequency: 50/60Hz

Control Components

Page 5: 6-Control Components

033 www.peopleelectric.com

JRS5 Series Thermal Overload Relay

Confirms to: IEC60947-4-1

Rated insulation voltage: 690V

Rated operating voltage: 380V

Rated current: 0.28A~105A

Auxiliary contacts: 1NO+1NC

Suited contactor: CJX5

Confirms to: IEC60947-4-1

Rated insulation voltage: 690V

Rated operating voltage: 660V

Rated current: 0.11A~500A

Auxiliary contacts: 1NO+1NC

Suited contactor: CJX8

JRS8 Series Thermal Overload Relay

RDJ2 Series Thermal Overload Relay

Confirms to: IEC60947-4-1

Rated insulation voltage: 690V

Rated operating voltage: 380V

Rated current: 0.1A~630A

Auxiliary contacts: 1NO+1NC

Suited contactor: CJX2

JR20 Series Thermal Overload Relay

Confirms to: IEC60947-4-1

Rated insulation voltage: 690V

Rated operating voltage: 660V

Rated current: 0.1A~630A

Auxiliary contacts: 1NO+1NC

Suited contactor: CJ20

JR36 Series Thermal Overload Relay

Confirms to: IEC60947-4-1

Rated insulation voltage: 690V

Rated operating voltage: 660V

Rated current: 0.35A~160A

Auxiliary contacts: 1NO+1NC

Suited contactor: CJT1

RDR6 Series Thermal Overload Relay

Confirms to: IEC60947-4-1

Rated insulation voltage: 690V

Rated operating voltage: 380V

Rated current: 0.1A~93A

Auxiliary contacts: 1NO+1NC

Suited contactor: CJX2

RDJD8 Series Residual Current Operated Relay

RDT8 Series Time Relay

Confirms to: GB/T22387

Rated operating voltage: AC 220V/AC 380V

Rated current: 250A, 400A, 630A

Rated residual operated current: 50mA~500mA

(adjustable)

It can be combined with AC contactor or circuit

breaker into leakage protective device

Voltage range: AC/DC 12-240V

Rated frequency: 50/60Hz

Number of contacts: 1×SPDT, 2×SPDT

Scope of delay: 0.1s - 10 days

DIN rail mounting

www.peopleelectric.com 034

ZN48 Series Time Relay

Confirms to: GB14048.5

Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V

Form of contacts: 1 sets of conversion

Scope of delay: 0.01s~99h59m

Counter range: 1~99999999

Ranges of accumulated time: 9999d23h59m

JS11S, JSS1P1, DH11S Series Time Relay

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V

Form of action: delay when electrified with instantly-acting

contacts

Form of contacts: instantly-acting 1 conversion and delay 2

conversion

Scope of delay: 0.01s~9999h

JS14A Series Time Relay

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V

Form of action: delay when electrified

Form of contacts: delay 2 conversion

Scope of delay: 1s, 5s, 10s, 30s, 60s, 120s, 180s 300s, 600s, 900s, 1800s, 3600s

JS20 Series Time Relay

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V

Form of action: delay when electrified

Form of contacts: delay 2 conversion

Scope of delay: 1s, 5s, 10s, 30s, 60s, 120s, 180s 300s, 600s, 900s, 1800s, 3600s

JS14C, JS14S, DH14S Series Time Relay

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V

Form of action: delay when electrified

Form of contacts: delay 2 conversion

Scope of delay: 0.01s~9999h

JS14P Series Time Relay

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V

Form of action: delay when electrified

Form of contacts: delay 2 conversion

Scope of delay: 0.01s~9999h

It can directly replace JS14A, JS20 etc. series

time relay

JSS1 Series Time Relay

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V

Form of action: delay when electrified, cycle delay

Form of contacts: delay 2 conversion

Scope of delay: 0.1s~9.9s, 0.1s~99.9s, 0.1s~999.9s 1s~99s, 1s~999s, 1s~9999s, 1s~99990s, 10s~990s, 10s~9990s, 1min~99min, 1min~999min, 1min~9999min

JSS72 Series Time Relay

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V

Form of action: delay when electrified

Form of contacts: delay 2 conversion

Scope of delay: 0.01s~9999h

Control Components

Page 6: 6-Control Components

033 www.peopleelectric.com

JRS5 Series Thermal Overload Relay

Confirms to: IEC60947-4-1

Rated insulation voltage: 690V

Rated operating voltage: 380V

Rated current: 0.28A~105A

Auxiliary contacts: 1NO+1NC

Suited contactor: CJX5

Confirms to: IEC60947-4-1

Rated insulation voltage: 690V

Rated operating voltage: 660V

Rated current: 0.11A~500A

Auxiliary contacts: 1NO+1NC

Suited contactor: CJX8

JRS8 Series Thermal Overload Relay

RDJ2 Series Thermal Overload Relay

Confirms to: IEC60947-4-1

Rated insulation voltage: 690V

Rated operating voltage: 380V

Rated current: 0.1A~630A

Auxiliary contacts: 1NO+1NC

Suited contactor: CJX2

JR20 Series Thermal Overload Relay

Confirms to: IEC60947-4-1

Rated insulation voltage: 690V

Rated operating voltage: 660V

Rated current: 0.1A~630A

Auxiliary contacts: 1NO+1NC

Suited contactor: CJ20

JR36 Series Thermal Overload Relay

Confirms to: IEC60947-4-1

Rated insulation voltage: 690V

Rated operating voltage: 660V

Rated current: 0.35A~160A

Auxiliary contacts: 1NO+1NC

Suited contactor: CJT1

RDR6 Series Thermal Overload Relay

Confirms to: IEC60947-4-1

Rated insulation voltage: 690V

Rated operating voltage: 380V

Rated current: 0.1A~93A

Auxiliary contacts: 1NO+1NC

Suited contactor: CJX2

RDJD8 Series Residual Current Operated Relay

RDT8 Series Time Relay

Confirms to: GB/T22387

Rated operating voltage: AC 220V/AC 380V

Rated current: 250A, 400A, 630A

Rated residual operated current: 50mA~500mA

(adjustable)

It can be combined with AC contactor or circuit

breaker into leakage protective device

Voltage range: AC/DC 12-240V

Rated frequency: 50/60Hz

Number of contacts: 1×SPDT, 2×SPDT

Scope of delay: 0.1s - 10 days

DIN rail mounting

www.peopleelectric.com 034

ZN48 Series Time Relay

Confirms to: GB14048.5

Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V

Form of contacts: 1 sets of conversion

Scope of delay: 0.01s~99h59m

Counter range: 1~99999999

Ranges of accumulated time: 9999d23h59m

JS11S, JSS1P1, DH11S Series Time Relay

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V

Form of action: delay when electrified with instantly-acting

contacts

Form of contacts: instantly-acting 1 conversion and delay 2

conversion

Scope of delay: 0.01s~9999h

JS14A Series Time Relay

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V

Form of action: delay when electrified

Form of contacts: delay 2 conversion

Scope of delay: 1s, 5s, 10s, 30s, 60s, 120s, 180s 300s, 600s, 900s, 1800s, 3600s

JS20 Series Time Relay

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V

Form of action: delay when electrified

Form of contacts: delay 2 conversion

Scope of delay: 1s, 5s, 10s, 30s, 60s, 120s, 180s 300s, 600s, 900s, 1800s, 3600s

JS14C, JS14S, DH14S Series Time Relay

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V

Form of action: delay when electrified

Form of contacts: delay 2 conversion

Scope of delay: 0.01s~9999h

JS14P Series Time Relay

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V

Form of action: delay when electrified

Form of contacts: delay 2 conversion

Scope of delay: 0.01s~9999h

It can directly replace JS14A, JS20 etc. series

time relay

JSS1 Series Time Relay

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V

Form of action: delay when electrified, cycle delay

Form of contacts: delay 2 conversion

Scope of delay: 0.1s~9.9s, 0.1s~99.9s, 0.1s~999.9s 1s~99s, 1s~999s, 1s~9999s, 1s~99990s, 10s~990s, 10s~9990s, 1min~99min, 1min~999min, 1min~9999min

JSS72 Series Time Relay

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V

Form of action: delay when electrified

Form of contacts: delay 2 conversion

Scope of delay: 0.01s~9999h

Control Components

Page 7: 6-Control Components

035 www.peopleelectric.com

JJSB1 Series Time Relay

Confirms to: GB14048.5

Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V

Form of action: delay when electrified

Form of contacts: delay 2 conversion

Scope of delay: 1s, 5s, 10s, 30s, 60s, 120s, 180s 300s, 600s, 900s, 1800s, 3600s

DH48S Series Time Relay

Confirms to: GB14048.5

Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V

Form of action: delay when electrified, DH48S-S is cycle delay

Form of contacts: DH48S is delay 1 conversion, DH48S-2H is instantly acting 1 conversion and delay 1 conversion, DH48S-2Z is delay 2 conversion

Scope of delay: 0.01s~99h99m

RDS3 Series Time Relay

Confirms to: GB14048.5

Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V

Form of action: delay when electrified or cycle delay

Form of contacts: delay 2 conversion or delay 1

conversion, instantly acting 1 conversion

Scope of delay: sec: 1, 5, 10, 30, 60, min: 3, 6, 10, 30, 60

Installation mode: panel type or device type

AH3 Series Time Relay

Confirms to: GB14048.5

Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V

Form of action: delay when electrified

Form of contacts: AH3-1 is delay 1 conversion, AH3-2 is delay 2 conversion, AH3-3 is instantly acting 1 conversion, delay 1 conversion

Scope of delay: sec: 1, 5, 10, 30, 60, min: 3, 6, 10, 30, 60

ST3P Series Time Relay

Confirms to: GB14048.5

Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V

Form of action: T3PA is delay when electrified ST3PF is delay when break, ST3PR is cycle delay

Form of contacts: ST3PA is delay 2 conversion, ST3PC is instantly acting conversion, delay 1 conversion, ST3PF is delay 1 conversion

Scope of delay: ST3PR: 1s~3600s, ST3PF: 1s~180s ST3PA (C)-A~F:0.5s~24h

ST6P Series Time Relay

Confirms to: GB14048.5

Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V

Form of action: delay when electrified

Form of contacts: ST6P-2 is delay 2 conversion,

ST6P-3 is delay 3 conversion, ST6P-4 is delay 4 conversion

Scope of delay: 1s~2h

JS7 Series Time Relay

Confirms to: GB14048.5

Rated operating voltage: AC 220V/380V

Form of action: JS7-1/2/3 is delay when electrified

JS7-4/5 is delay when break

Form of contacts: JS7-1/3/5 is delay 1 conversion,

JS7-2/4 is instantly acting 1 conversion delay 1 conversion

Scope of delay: 30s, 60s, 120s, 180s

DS Series Time Relay

Confirms to: GB14048.5

Rated insulation voltage: 380V

Rated voltage: up to 380V, DC 250V

www.peopleelectric.com 036

DL, DY Series Current Voltage Relay

Setting scope of DL (A): 0.0025~0.01, 0.01~0.04 0.0125~0.05, 0.05~0.2 0.15~0.6, 0.5~2, 1.5~6 2.5~10, 5~20, 12.5~50

Voltage setting scope of DY (Y): 15~60, 12~48 40~160, 50~200 80~320, 100~400

JL12 Series Current Relay

Confirms to: GB14048.5

Rated voltage: 380V

Rated current of coil: 5A~300A

JL14 Series Current Relay

Confirms to: GB14048.5

Rated voltage: AC380V, DC220V

Rated current of coil: 1A~600A

JL15 Series Current Relay

Confirms to: GB14048.5

Rated voltage: AC380V, DC440V

Rated current of coil: 1A~600A

JL18 Series Current Relay

Confirms to: GB14048.5

Rated voltage: AC380V, DC440V

Rated current of coil: 1A~630A

DX Series Signal Relay

Rated voltage: 12V, 24V, 48V, 110V, 220V

Rated current: 0.01A~4A

HH52P, 53P, 54P Series General Relay

Confirms to: GB14048.5, IEC61810-1

Rated insulation voltage: 380V

Voltage of coil: up to AC 380V, DC 220V

Group no. of contacts: HH52P has 2 groups of contacts HH53P has 3 groups of contacts HH54P has 4 groups of contacts

Control voltage of coil: AC 6V~380V DC 6V~220V

JQX Series General Relay

Confirms to: GB14048.5, IEC61810-1

Rated operating voltage: AC 220V, 380V, DC220V

Voltage of coil: up to AC380V, DC220V

Group no. of contacts: 2Z is 2 groups of contacts, 3Z is 3 groups of contacts

Control voltage of coil: AC6V~380V DC6V~220V

Control Components

Page 8: 6-Control Components

035 www.peopleelectric.com

JJSB1 Series Time Relay

Confirms to: GB14048.5

Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V

Form of action: delay when electrified

Form of contacts: delay 2 conversion

Scope of delay: 1s, 5s, 10s, 30s, 60s, 120s, 180s 300s, 600s, 900s, 1800s, 3600s

DH48S Series Time Relay

Confirms to: GB14048.5

Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V

Form of action: delay when electrified, DH48S-S is cycle delay

Form of contacts: DH48S is delay 1 conversion, DH48S-2H is instantly acting 1 conversion and delay 1 conversion, DH48S-2Z is delay 2 conversion

Scope of delay: 0.01s~99h99m

RDS3 Series Time Relay

Confirms to: GB14048.5

Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V AC/DC110~250V

Form of action: delay when electrified or cycle delay

Form of contacts: delay 2 conversion or delay 1

conversion, instantly acting 1 conversion

Scope of delay: sec: 1, 5, 10, 30, 60, min: 3, 6, 10, 30, 60

Installation mode: panel type or device type

AH3 Series Time Relay

Confirms to: GB14048.5

Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V

Form of action: delay when electrified

Form of contacts: AH3-1 is delay 1 conversion, AH3-2 is delay 2 conversion, AH3-3 is instantly acting 1 conversion, delay 1 conversion

Scope of delay: sec: 1, 5, 10, 30, 60, min: 3, 6, 10, 30, 60

ST3P Series Time Relay

Confirms to: GB14048.5

Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V

Form of action: T3PA is delay when electrified ST3PF is delay when break, ST3PR is cycle delay

Form of contacts: ST3PA is delay 2 conversion, ST3PC is instantly acting conversion, delay 1 conversion, ST3PF is delay 1 conversion

Scope of delay: ST3PR: 1s~3600s, ST3PF: 1s~180s ST3PA (C)-A~F:0.5s~24h

ST6P Series Time Relay

Confirms to: GB14048.5

Rated operating voltage: AC 12V~380V 50/60Hz DC12V~24V

Form of action: delay when electrified

Form of contacts: ST6P-2 is delay 2 conversion,

ST6P-3 is delay 3 conversion, ST6P-4 is delay 4 conversion

Scope of delay: 1s~2h

JS7 Series Time Relay

Confirms to: GB14048.5

Rated operating voltage: AC 220V/380V

Form of action: JS7-1/2/3 is delay when electrified

JS7-4/5 is delay when break

Form of contacts: JS7-1/3/5 is delay 1 conversion,

JS7-2/4 is instantly acting 1 conversion delay 1 conversion

Scope of delay: 30s, 60s, 120s, 180s

DS Series Time Relay

Confirms to: GB14048.5

Rated insulation voltage: 380V

Rated voltage: up to 380V, DC 250V

www.peopleelectric.com 036

DL, DY Series Current Voltage Relay

Setting scope of DL (A): 0.0025~0.01, 0.01~0.04 0.0125~0.05, 0.05~0.2 0.15~0.6, 0.5~2, 1.5~6 2.5~10, 5~20, 12.5~50

Voltage setting scope of DY (Y): 15~60, 12~48 40~160, 50~200 80~320, 100~400

JL12 Series Current Relay

Confirms to: GB14048.5

Rated voltage: 380V

Rated current of coil: 5A~300A

JL14 Series Current Relay

Confirms to: GB14048.5

Rated voltage: AC380V, DC220V

Rated current of coil: 1A~600A

JL15 Series Current Relay

Confirms to: GB14048.5

Rated voltage: AC380V, DC440V

Rated current of coil: 1A~600A

JL18 Series Current Relay

Confirms to: GB14048.5

Rated voltage: AC380V, DC440V

Rated current of coil: 1A~630A

DX Series Signal Relay

Rated voltage: 12V, 24V, 48V, 110V, 220V

Rated current: 0.01A~4A

HH52P, 53P, 54P Series General Relay

Confirms to: GB14048.5, IEC61810-1

Rated insulation voltage: 380V

Voltage of coil: up to AC 380V, DC 220V

Group no. of contacts: HH52P has 2 groups of contacts HH53P has 3 groups of contacts HH54P has 4 groups of contacts

Control voltage of coil: AC 6V~380V DC 6V~220V

JQX Series General Relay

Confirms to: GB14048.5, IEC61810-1

Rated operating voltage: AC 220V, 380V, DC220V

Voltage of coil: up to AC380V, DC220V

Group no. of contacts: 2Z is 2 groups of contacts, 3Z is 3 groups of contacts

Control voltage of coil: AC6V~380V DC6V~220V

Control Components

Page 9: 6-Control Components

037 www.peopleelectric.com

JTX Series General Relay JQX-13F Series General Relay

RDSJ Series Ultra-Thin Relay RDJ Series Ultra-Thin Relay

SSR Series Solid State Relay GJ Series Solid State Relay

JYB Series Liquid-Level Relay KG316T, KG316TX Series Time-Controlled Switch

Confirms to: GB14048.5, IEC61810-1

Rated operating voltage: AC220V, 380V, DC220V

Group no. of contacts: 2C is 2 groups of contacts 3C is 3 groups of contacts

Control voltage of coil: AC6V~380V DC6V~220V

Confirms to: GB14048.5, IEC61810-1

Rated operating voltage: AC220V, 380V, DC220V

Group no. of contacts: 2 groups of contacts

Control voltage of coil: AC6V~380V DC6V~220V

Confirms to: GB14048.5

Control voltage: AC12V~230V, DC12V~230V

Rated current: 6A

Confirms to: GB14048.5

Control voltage: DC12V~60V

Rated current: 6A

Control voltage: DC3~32V

Operating current: (ordinary type) 1A~40A (enhanced type) 4A~320A

Operating voltage: AC 220V/380V

Control voltage: DC3~32V

Operating current: (ordinary type) 5A~40A (industrial type) 40A~1000A

Operating voltage: AC 220V~380V

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 36V, 110V, 220V 380V 50/60Hz

Operating mode: JYB-2 displacement type, JYB-3, JYB-4 water supply type

Quantity of contacts: 1 group of conversion

Capacity of contacts: AC 250V 10A (resistance)

Confirms to: GB14048.5

Rated operating voltage: AC110~240V 50/60Hz

Form of contacts: delay 1 conversion

Form of acting: timing of action

Scope of delay: 1min~168h

KG16A Series Time-Controlled Switch

Confirms to: GB14048.5

Rated operating voltage: AC110~240V 50/60Hz

Form of contacts: delay 1 conversion

Form of acting: timing of action

Scope of delay: 1min~168h

KG10 Series Time-Controlled Switch

Confirms to: GB14048.5

Rated operating voltage: AC110~240V 50/60Hz

Form of contacts: delay 1 conversion

Form of acting: timing of action

Scope of delay: 1min~168h

KG10YG Series Time-Controlled Switch

Confirms to: GB14048.5

Rated operating voltage: AC110~240V 50/60Hz

Form of contacts: delay 1 conversion

Form of acting: timing of action

Scope of delay: 1min~168h

GUK Series Road lamp Light-Controlled Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC220V 50Hz

Light control device: light sensitive resistor

Rated load: GUK-81:10A, GUK-82:40A,

GUK-83:60A, GUK-84:100A

KG-2 (GUK-2) Series Street Lamp Light-controlled Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC220V 50Hz

Light control device: light-sensitive dioder

Rated load: AC250V 3A

KG20L Series Full-automatic Bell Instrument

Confirms to: GB14048.5

Rated operating voltage: AC110~24V 50/60Hz

Form of contacts: delay 1 conversion

Form of acting: timing of action

Belling frequency within 24h: 20 times

Time of belling: 1min~168h

RDJ1-48 (DH48J) Series Counter

Confirms to: GB14048.5

Rated operating voltage: AC 12~380V 50/60Hz DC12~24V

Form of contacts: 1 conversion

Form of acting: contacts, impact, photoelectric counting

Counting range: 1~9999 (1*10*100)

RDJ1-14 (DH14J) Series Counter

Confirms to: GB14048.5

Rated operating voltage: AC 12~380V 50/60Hz DC12~24V

Form of contacts: 1 conversion

Form of acting: contacts, impact, photoelectric counting

Counting range: 1~9999 (1*10*100)

www.peopleelectric.com 038

Control Components

Page 10: 6-Control Components

037 www.peopleelectric.com

JTX Series General Relay JQX-13F Series General Relay

RDSJ Series Ultra-Thin Relay RDJ Series Ultra-Thin Relay

SSR Series Solid State Relay GJ Series Solid State Relay

JYB Series Liquid-Level Relay KG316T, KG316TX Series Time-Controlled Switch

Confirms to: GB14048.5, IEC61810-1

Rated operating voltage: AC220V, 380V, DC220V

Group no. of contacts: 2C is 2 groups of contacts 3C is 3 groups of contacts

Control voltage of coil: AC6V~380V DC6V~220V

Confirms to: GB14048.5, IEC61810-1

Rated operating voltage: AC220V, 380V, DC220V

Group no. of contacts: 2 groups of contacts

Control voltage of coil: AC6V~380V DC6V~220V

Confirms to: GB14048.5

Control voltage: AC12V~230V, DC12V~230V

Rated current: 6A

Confirms to: GB14048.5

Control voltage: DC12V~60V

Rated current: 6A

Control voltage: DC3~32V

Operating current: (ordinary type) 1A~40A (enhanced type) 4A~320A

Operating voltage: AC 220V/380V

Control voltage: DC3~32V

Operating current: (ordinary type) 5A~40A (industrial type) 40A~1000A

Operating voltage: AC 220V~380V

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 36V, 110V, 220V 380V 50/60Hz

Operating mode: JYB-2 displacement type, JYB-3, JYB-4 water supply type

Quantity of contacts: 1 group of conversion

Capacity of contacts: AC 250V 10A (resistance)

Confirms to: GB14048.5

Rated operating voltage: AC110~240V 50/60Hz

Form of contacts: delay 1 conversion

Form of acting: timing of action

Scope of delay: 1min~168h

KG16A Series Time-Controlled Switch

Confirms to: GB14048.5

Rated operating voltage: AC110~240V 50/60Hz

Form of contacts: delay 1 conversion

Form of acting: timing of action

Scope of delay: 1min~168h

KG10 Series Time-Controlled Switch

Confirms to: GB14048.5

Rated operating voltage: AC110~240V 50/60Hz

Form of contacts: delay 1 conversion

Form of acting: timing of action

Scope of delay: 1min~168h

KG10YG Series Time-Controlled Switch

Confirms to: GB14048.5

Rated operating voltage: AC110~240V 50/60Hz

Form of contacts: delay 1 conversion

Form of acting: timing of action

Scope of delay: 1min~168h

GUK Series Road lamp Light-Controlled Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC220V 50Hz

Light control device: light sensitive resistor

Rated load: GUK-81:10A, GUK-82:40A,

GUK-83:60A, GUK-84:100A

KG-2 (GUK-2) Series Street Lamp Light-controlled Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC220V 50Hz

Light control device: light-sensitive dioder

Rated load: AC250V 3A

KG20L Series Full-automatic Bell Instrument

Confirms to: GB14048.5

Rated operating voltage: AC110~24V 50/60Hz

Form of contacts: delay 1 conversion

Form of acting: timing of action

Belling frequency within 24h: 20 times

Time of belling: 1min~168h

RDJ1-48 (DH48J) Series Counter

Confirms to: GB14048.5

Rated operating voltage: AC 12~380V 50/60Hz DC12~24V

Form of contacts: 1 conversion

Form of acting: contacts, impact, photoelectric counting

Counting range: 1~9999 (1*10*100)

RDJ1-14 (DH14J) Series Counter

Confirms to: GB14048.5

Rated operating voltage: AC 12~380V 50/60Hz DC12~24V

Form of contacts: 1 conversion

Form of acting: contacts, impact, photoelectric counting

Counting range: 1~9999 (1*10*100)

www.peopleelectric.com 038

Control Components

Page 11: 6-Control Components

039 www.peopleelectric.com

RDJ1-12 Series Counter

Confirms to: GB14048.5

Rated operating voltage: AC 12~380V 50/60Hz DC12~24V

Form of contacts: 1 conversion

Form of acting: contacts, impact, photoelectric counting

Counting range: 1~9999

RDJ1-9 (JDM9) Series Counter

Confirms to: GB14048.5

Rated operating voltage: AC 12~380V 50/60Hz DC12~24V

Form of contacts: 1 conversion

Form of acting: contacts, impact, photoelectric counting

Counting range: 1~9999

RDJ1-3 (JDM3) Series Counter

Confirms to: GB14048.5

Rated operating voltage: AC 12~380V 50/60Hz DC12~24V

Form of contacts: 1 conversion

Form of acting: contacts, impact, photoelectric counting

Counting range: 1~9999

RDJ1-3 (JDM3) Series Counter

Confirms to: GB14048.5

Rated operating voltage: AC 12~380V 50/60Hz DC12~24V

Form of contacts: 1 conversion

Form of acting: contacts, impact, photoelectric counting

Counting range: 1~9999

RDL-3 (SC3L) Series Time-Accumulator

RDL1-48 (DH48L) Series Time-Accumulator

RDJ-3, RDJX-3S Series Over-Voltageand Under-Voltage Protection Auto-Controller

RDJX-2 Series Electronic Load-LimitAuto-Controller

Confirms to: GB14048.5

Timing range: 1s~9999d23h

Confirms to: GB14048.5

Rated operating voltage: AC12~380V 50/60Hz DC12~24V

Timing range: 1s~9999.9h

Rated operating voltage: AC 220V 50/60Hz

Over-voltage protection value: 265V±5V

Under-voltage protection value: 170V±5V

Rated load: 20A, 32A, 40A, 63A

Rated operating voltage: AC 220V 50/60Hz

Over-current protection value: 1A, 3A, 5A, 10A, 15A, 20A, 32A, 40A

www.peopleelectric.com 040

LX3 Series Limit Switch LX5 Series Limit Switch

LX8 Series Limit Switch LX10 Series Limit Switch

LX19 Series Limit Switch LX22 Series Limit Switch

LX44 Series Limit Switch LXP1 Series Limit Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Rated operating current: AC 0.79A, DC 0.15A

Setting thermal current: 5A

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V

Rated operating current: AC 0.26A

Setting thermal current: 3A

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Rated operating current: AC 2.63A, DC 0.91A

Setting thermal current: 20A

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Rated operating current: AC 0.79A, DC 0.91A

Setting thermal current: 10A

It can be with the sealing function, and satisfying

the waterproof requirements

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Rated operating current: AC 0.79A, DC 0.1A

Setting thermal current: 5A

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Rated operating current: AC 20A, DC 0.2A

Setting thermal current: 20A

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V

Setting thermal current: 10A, 20A, 40A

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Rated operating current: AC 5A, DC 0.15A

Setting thermal current: 10A

Control Components

Page 12: 6-Control Components

039 www.peopleelectric.com

RDJ1-12 Series Counter

Confirms to: GB14048.5

Rated operating voltage: AC 12~380V 50/60Hz DC12~24V

Form of contacts: 1 conversion

Form of acting: contacts, impact, photoelectric counting

Counting range: 1~9999

RDJ1-9 (JDM9) Series Counter

Confirms to: GB14048.5

Rated operating voltage: AC 12~380V 50/60Hz DC12~24V

Form of contacts: 1 conversion

Form of acting: contacts, impact, photoelectric counting

Counting range: 1~9999

RDJ1-3 (JDM3) Series Counter

Confirms to: GB14048.5

Rated operating voltage: AC 12~380V 50/60Hz DC12~24V

Form of contacts: 1 conversion

Form of acting: contacts, impact, photoelectric counting

Counting range: 1~9999

RDJ1-3 (JDM3) Series Counter

Confirms to: GB14048.5

Rated operating voltage: AC 12~380V 50/60Hz DC12~24V

Form of contacts: 1 conversion

Form of acting: contacts, impact, photoelectric counting

Counting range: 1~9999

RDL-3 (SC3L) Series Time-Accumulator

RDL1-48 (DH48L) Series Time-Accumulator

RDJ-3, RDJX-3S Series Over-Voltageand Under-Voltage Protection Auto-Controller

RDJX-2 Series Electronic Load-LimitAuto-Controller

Confirms to: GB14048.5

Timing range: 1s~9999d23h

Confirms to: GB14048.5

Rated operating voltage: AC12~380V 50/60Hz DC12~24V

Timing range: 1s~9999.9h

Rated operating voltage: AC 220V 50/60Hz

Over-voltage protection value: 265V±5V

Under-voltage protection value: 170V±5V

Rated load: 20A, 32A, 40A, 63A

Rated operating voltage: AC 220V 50/60Hz

Over-current protection value: 1A, 3A, 5A, 10A, 15A, 20A, 32A, 40A

www.peopleelectric.com 040

LX3 Series Limit Switch LX5 Series Limit Switch

LX8 Series Limit Switch LX10 Series Limit Switch

LX19 Series Limit Switch LX22 Series Limit Switch

LX44 Series Limit Switch LXP1 Series Limit Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Rated operating current: AC 0.79A, DC 0.15A

Setting thermal current: 5A

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V

Rated operating current: AC 0.26A

Setting thermal current: 3A

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Rated operating current: AC 2.63A, DC 0.91A

Setting thermal current: 20A

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Rated operating current: AC 0.79A, DC 0.91A

Setting thermal current: 10A

It can be with the sealing function, and satisfying

the waterproof requirements

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Rated operating current: AC 0.79A, DC 0.1A

Setting thermal current: 5A

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Rated operating current: AC 20A, DC 0.2A

Setting thermal current: 20A

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V

Setting thermal current: 10A, 20A, 40A

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Rated operating current: AC 5A, DC 0.15A

Setting thermal current: 10A

Control Components

Page 13: 6-Control Components

041 www.peopleelectric.com

JLXK1 Series Limit Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Rated operating current: AC 5A, DC 0.15A

Setting thermal current: 5A

Structure: single-wheel, double-wheels, direct-

acting without wheels, direct-acting with wheels

X2 Series Limit Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V

Rated operating current: AC 2AIt can control two independent circuit at the sametime.

Structure: drive roller, direct-acting type

JW2 Series Limit Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Rated operating current: AC 3A, DC 0.42A

Setting thermal current: 3A

LXK3 Series Limit Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Rated operating current: AC 5A, DC 0.15A

Setting thermal current: 10A

RDLX18 Series Limit Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Rated operating current: AC 0.8A, DC 0.16A

Setting thermal current: 5A

WL Series Limit Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Rated operating current: AC 0.79A, DC 0.15A

Setting thermal current: 5A

HL Series Limit Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Rated operating current: AC 0.79A, DC 0.15A

Setting thermal current: 5A

GYD20 Series Barometric Switch

Confirms to: GB14048.5

Rated operating voltage: 380V or 220V

Rated operating current: 20A, 16A

It is used for the occasion of barometric auto-control

www.peopleelectric.com 042

CM Series Micro Switch

Confirms to: GB14048.5, IEC60947-5-1

Operation speed: 0.01mm to 1m/swc

Rated frequency: 50/60Hz

Scope of application: it is mainly used for the limit

control limit protection and interlock of the machinery

equipments for the machinery, textile, light industry,

electronic instrument

EKW Series Foot Switch

Confirms to: GB14048.5

Rated operating voltage: 380V

Rated operating power: 300VA

Setting thermal current: 5A

YDT1 Series Foot Switch

Confirms to: GB14048.5

Rated operating voltage: AC 380V, DC 220V

Setting thermal current: 5A

LW5 Series Universal Change-Over Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Setting thermal current: 16A

Strong change-over ability, high operation frequency,

and strong connecting and breaking ability etc.

It is used for the change-over electrics to control

circuit (electromagnetic coil, servo motor etc.)

LW6 Series Universal Change-Over Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Setting thermal current: 5A

Many pole number of contacts, and many transfer

circuit etc., which is used for the controlling and

transferring electric circuit etc. of machinery circuit.

LW8 Series Universal Change-Over Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Setting thermal current: 10A, 20A

Strong change-over ability, high operation frequency,

and strong connecting and breaking ability etc.

It is used for the change-over electrics to control

circuit (electromagnetic coil, servo motor etc.)

LW12 Series Universal Change-Over Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Rated operating current: AC 2.6A, DC 0.27A

High operation frequency, and strong connecting and breaking ability etc.

It is used for the change-over electrics to control servocircuit (electromagnetic coil, motor etc.)

LW26 Series Universal Change-Over Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Setting thermal current: 20A~160A

High operation frequency, and strong connecting and breaking ability etc.

It is used for the change-over electrics to control

circuit (electromagnetic coil, servo motor etc.)

Control Components

Page 14: 6-Control Components

041 www.peopleelectric.com

JLXK1 Series Limit Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Rated operating current: AC 5A, DC 0.15A

Setting thermal current: 5A

Structure: single-wheel, double-wheels, direct-

acting without wheels, direct-acting with wheels

X2 Series Limit Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V

Rated operating current: AC 2AIt can control two independent circuit at the sametime.

Structure: drive roller, direct-acting type

JW2 Series Limit Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Rated operating current: AC 3A, DC 0.42A

Setting thermal current: 3A

LXK3 Series Limit Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Rated operating current: AC 5A, DC 0.15A

Setting thermal current: 10A

RDLX18 Series Limit Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Rated operating current: AC 0.8A, DC 0.16A

Setting thermal current: 5A

WL Series Limit Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Rated operating current: AC 0.79A, DC 0.15A

Setting thermal current: 5A

HL Series Limit Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Rated operating current: AC 0.79A, DC 0.15A

Setting thermal current: 5A

GYD20 Series Barometric Switch

Confirms to: GB14048.5

Rated operating voltage: 380V or 220V

Rated operating current: 20A, 16A

It is used for the occasion of barometric auto-control

www.peopleelectric.com 042

CM Series Micro Switch

Confirms to: GB14048.5, IEC60947-5-1

Operation speed: 0.01mm to 1m/swc

Rated frequency: 50/60Hz

Scope of application: it is mainly used for the limit

control limit protection and interlock of the machinery

equipments for the machinery, textile, light industry,

electronic instrument

EKW Series Foot Switch

Confirms to: GB14048.5

Rated operating voltage: 380V

Rated operating power: 300VA

Setting thermal current: 5A

YDT1 Series Foot Switch

Confirms to: GB14048.5

Rated operating voltage: AC 380V, DC 220V

Setting thermal current: 5A

LW5 Series Universal Change-Over Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Setting thermal current: 16A

Strong change-over ability, high operation frequency,

and strong connecting and breaking ability etc.

It is used for the change-over electrics to control

circuit (electromagnetic coil, servo motor etc.)

LW6 Series Universal Change-Over Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Setting thermal current: 5A

Many pole number of contacts, and many transfer

circuit etc., which is used for the controlling and

transferring electric circuit etc. of machinery circuit.

LW8 Series Universal Change-Over Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Setting thermal current: 10A, 20A

Strong change-over ability, high operation frequency,

and strong connecting and breaking ability etc.

It is used for the change-over electrics to control

circuit (electromagnetic coil, servo motor etc.)

LW12 Series Universal Change-Over Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Rated operating current: AC 2.6A, DC 0.27A

High operation frequency, and strong connecting and breaking ability etc.

It is used for the change-over electrics to control servocircuit (electromagnetic coil, motor etc.)

LW26 Series Universal Change-Over Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Setting thermal current: 20A~160A

High operation frequency, and strong connecting and breaking ability etc.

It is used for the change-over electrics to control

circuit (electromagnetic coil, servo motor etc.)

Control Components

Page 15: 6-Control Components

043 www.peopleelectric.com

HZ10 Series Combination Switch HY2 Series Reversing Switch

QS Series Reversing Switch QX1-13N Series Reversible Switch

RDA1 Series Pushbutton Switch RDA2 Series Pushbutton Switch

RDA37 Series Pushbutton Switch RDA38 Series Pushbutton Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V DC 220V

Rated operating current: AC 10A~100A DC 10A, 25A, 60A, 100A

It is used for infrequently connecting and breaking

motor’s circuit etc.

Confirms to: GB14048.3

Rated operating voltage: 380V, 220V

Setting thermal current: 15A, 30A, 60A

Rated operating power: 1.8kW~10kW

Confirms to: GB14048.3

Rated operating voltage: up to 500V

Setting thermal current: 15A, 30A, 60A

Rated operating power: 4kW~7.5kW

Confirms to: GB14048.3

Rated operating voltage: 380V

Setting thermal current: 12A, 16A, 40A

Rated operating power: 5.5kW~30kW

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V DC 220V

Setting thermal current: 10A

Hole size of installation board: φ22.3

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 400V DC 230V

Setting thermal current: 10A

Hole size of installation board: φ22.3

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V DC 220V

Setting thermal current: 10A

Hole size of installation board: φ22.3

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V DC 220V

Setting thermal current: 10A

Hole size of installation board: φ22.3

PXB2 Series Pushbutton Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V DC 220V

Setting thermal current: 10A

Hole size of installation board: φ22.3

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V DC 220V

Setting thermal current: 10A

Hole size of installation board: φ30

LA2 Series Pushbutton Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V DC 220V

Setting thermal current: 10A

PXAL Series Pushbutton Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V DC 220V

Setting thermal current: 10A

LA10 Series Pushbutton Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V DC 220V

Setting thermal current: 5A

Hole size of installation board: φ24.5

LA18 Series Pushbutton Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V DC 220V

Setting thermal current: 5A

Hole size of installation board: φ24.5

LA19 Series Pushbutton Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V DC 220V

Setting thermal current: 5A

Simple structure, convenient installation and wiring

Hole size of installation board: φ22.3

LAY3 Series Pushbutton Switch COB Series Pushbutton Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Rated operating current: 2.5A, 0.3A

It is used for the control of crane, electric block, etc.

Mechanical interlock between pushbuttons, such

as up and down, left and right, etc.

www.peopleelectric.com 044

Control Components

Page 16: 6-Control Components

043 www.peopleelectric.com

HZ10 Series Combination Switch HY2 Series Reversing Switch

QS Series Reversing Switch QX1-13N Series Reversible Switch

RDA1 Series Pushbutton Switch RDA2 Series Pushbutton Switch

RDA37 Series Pushbutton Switch RDA38 Series Pushbutton Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V DC 220V

Rated operating current: AC 10A~100A DC 10A, 25A, 60A, 100A

It is used for infrequently connecting and breaking

motor’s circuit etc.

Confirms to: GB14048.3

Rated operating voltage: 380V, 220V

Setting thermal current: 15A, 30A, 60A

Rated operating power: 1.8kW~10kW

Confirms to: GB14048.3

Rated operating voltage: up to 500V

Setting thermal current: 15A, 30A, 60A

Rated operating power: 4kW~7.5kW

Confirms to: GB14048.3

Rated operating voltage: 380V

Setting thermal current: 12A, 16A, 40A

Rated operating power: 5.5kW~30kW

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V DC 220V

Setting thermal current: 10A

Hole size of installation board: φ22.3

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 400V DC 230V

Setting thermal current: 10A

Hole size of installation board: φ22.3

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V DC 220V

Setting thermal current: 10A

Hole size of installation board: φ22.3

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V DC 220V

Setting thermal current: 10A

Hole size of installation board: φ22.3

PXB2 Series Pushbutton Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V DC 220V

Setting thermal current: 10A

Hole size of installation board: φ22.3

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V DC 220V

Setting thermal current: 10A

Hole size of installation board: φ30

LA2 Series Pushbutton Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V DC 220V

Setting thermal current: 10A

PXAL Series Pushbutton Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V DC 220V

Setting thermal current: 10A

LA10 Series Pushbutton Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V DC 220V

Setting thermal current: 5A

Hole size of installation board: φ24.5

LA18 Series Pushbutton Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V DC 220V

Setting thermal current: 5A

Hole size of installation board: φ24.5

LA19 Series Pushbutton Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V DC 220V

Setting thermal current: 5A

Simple structure, convenient installation and wiring

Hole size of installation board: φ22.3

LAY3 Series Pushbutton Switch COB Series Pushbutton Switch

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Rated operating current: 2.5A, 0.3A

It is used for the control of crane, electric block, etc.

Mechanical interlock between pushbuttons, such

as up and down, left and right, etc.

www.peopleelectric.com 044

Control Components

Page 17: 6-Control Components

045 www.peopleelectric.com

BS Pushbutton Power Switch AD11 Series Signal Lamp

AD16 Series BuzzerAD22 Series Indicator Lamp

JD-5 Series Motor Synthetical Protector

JD-6 Series Motor Synthetical Protector

JD-5E Series Motor Synthetical Protector

JD-8 Series Motor Synthetical Protector

Confirms to: GB14048.5, IEC60947-5-1

Rated voltage: AC 380V

Rated operating current: 4A, 6A, 10A

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Setting thermal current: 10A

Uses LED illuminate, high brightness, low

energy-consumption

Hole size of AD11-22 installation board is φ22.3

Hole size of AD11-25 installation board is φ25.5

Hole size of AD11-30 installation board is φ30.5 Screw type concealed wiring

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: 6V, 12V, 24V, 36V, 48V, 110V, 127V, 220V, 380V

Setting thermal current: 10A

Uses LED illuminate, high brightness, low

energy-consumption

Hole size of AD11-22 installation board is φ22.3

Screw type concealed wiring, plug-type wiring

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: 6V, 12V, 24V, 36V, 48V, 110V, 127V, 220V, 380V

Rated operating current: ≤20mA

Uses LED illuminate, high brightness, low

energy-consumption

Hole size of AD11-22 installation board is φ22.3

Screw type concealed wiring, plug-type wiring

Confirms to: G14048.4

Rated operating voltage: AC 220V/380V

Rated current: 0.5A~100A

Capacity of contacts: 1 group of NC contacts,

AC 220V 5A

Releasing grade: 10A 3P

With over-load and break phase protective

function

Confirms to: G14048.4

Rated operating voltage: AC 220V/380V

Rated current: 0.5A~100A

Capacity of contacts: 1 group of NC contacts,

AC 220V 5A

Releasing grade: 10A 3P

With over-load and break phase protective

function

Confirms to: G14048.4

Rated operating voltage: AC 220V/380V

Rated current: 0.5A~100A

Capacity of contacts: 1 group of NC contacts,

AC 220V 5A

Releasing grade: 10A 3P

With over-load and break phase protective

function

Confirms to: G14048.4

Rated operating voltage: AC 220V/380V

Rated current: 0.5A~60A

Capacity of contacts: 1 group of NC contacts,

AC 220V 5A

Releasing grade: 10A 3P

With over-load and break phase protective

function

www.peopleelectric.com 046

RHQ-S-C Series Motor Synthetical Protector

Confirms to: G14048.4

Rated operating voltage: AC 220V/380V

Rated current: 0.5A~400A

Capacity of contacts: 1 group of NC contacts,

AC 220V 5A

Releasing grade: 10A 3P

With over-load and break phase protective

function

XJ Series Break Phase and Phase-Sequence Protective Controller

Confirms to: G14048.5

Rated operating voltage: AC 380V 50/60Hz

Output of contacts: 1NO, 1NC

Capacity of contacts: AC 250V 5A (Resistance)

XJ01 Series Auto-Coupling ReducedVoltage Starter

Confirms to: GB14048.4

Frame size: 30, 75, 115, 190, 300, 400

Rated power: 14kW~400kW

Rated current: 28A~800A

Operating voltage: 380V/three phase

Suited motor: squirrel-cage three phase AC

asynchronous motor

Installation mode: box type structure floor install

JJ1 Series Auto-Coupling ReducedVoltage Starter

Confirms to: GB14048.4

Frame size: 30, 75, 115, 190, 300, 400

Rated power: 14kW~400kW

Rated current: 28A~800A

Operating voltage: 380V/three phase

Suited motor: squirrel-cage three phase AC

asynchronous motor

Installation mode: box type structure floor install

QX1 Series Star-Delta Starter

Confirms to: GB14048.3

Frame size: 13, 13N, 13

Rated power: 13kW~30kW

Rated frequency: 50/60Hz

Operating voltage: 380V/three phase

QX4 Series Star-Delta Starter

Confirms to: GB14048.4

Frame size: 17, 30, 55, 75

Rated power: 13kW~75kW

Rated current: 28A~85A

Operating voltage: 380V/three phase

Suited motor: squirrel-cage three phase AC

asynchronous motor Installation mode: box type structure floor or

wall type install

QJX2 Series Star-Delta Starter

Confirms to: GB14048.4

Rated operating current: 12A~95A

Rated insulation voltage: 660V

Control voltage of coil: AC 24V/36V/48V/110V/127V/ 220V/380V/440V/660V

RDQ12 Series Electromagnetic Starter

Confirms to: GB14048.4

Rated operating current: 10A~150A

Rated insulation voltage: 380V

Control voltage of coil: AC 24V/36V/48V/110V/127V/ 220V/380V/440V/660V

Control Components

Page 18: 6-Control Components

045 www.peopleelectric.com

BS Pushbutton Power Switch AD11 Series Signal Lamp

AD16 Series BuzzerAD22 Series Indicator Lamp

JD-5 Series Motor Synthetical Protector

JD-6 Series Motor Synthetical Protector

JD-5E Series Motor Synthetical Protector

JD-8 Series Motor Synthetical Protector

Confirms to: GB14048.5, IEC60947-5-1

Rated voltage: AC 380V

Rated operating current: 4A, 6A, 10A

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: AC 380V, DC 220V

Setting thermal current: 10A

Uses LED illuminate, high brightness, low

energy-consumption

Hole size of AD11-22 installation board is φ22.3

Hole size of AD11-25 installation board is φ25.5

Hole size of AD11-30 installation board is φ30.5 Screw type concealed wiring

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: 6V, 12V, 24V, 36V, 48V, 110V, 127V, 220V, 380V

Setting thermal current: 10A

Uses LED illuminate, high brightness, low

energy-consumption

Hole size of AD11-22 installation board is φ22.3

Screw type concealed wiring, plug-type wiring

Confirms to: GB14048.5, IEC60947-5-1

Rated operating voltage: 6V, 12V, 24V, 36V, 48V, 110V, 127V, 220V, 380V

Rated operating current: ≤20mA

Uses LED illuminate, high brightness, low

energy-consumption

Hole size of AD11-22 installation board is φ22.3

Screw type concealed wiring, plug-type wiring

Confirms to: G14048.4

Rated operating voltage: AC 220V/380V

Rated current: 0.5A~100A

Capacity of contacts: 1 group of NC contacts,

AC 220V 5A

Releasing grade: 10A 3P

With over-load and break phase protective

function

Confirms to: G14048.4

Rated operating voltage: AC 220V/380V

Rated current: 0.5A~100A

Capacity of contacts: 1 group of NC contacts,

AC 220V 5A

Releasing grade: 10A 3P

With over-load and break phase protective

function

Confirms to: G14048.4

Rated operating voltage: AC 220V/380V

Rated current: 0.5A~100A

Capacity of contacts: 1 group of NC contacts,

AC 220V 5A

Releasing grade: 10A 3P

With over-load and break phase protective

function

Confirms to: G14048.4

Rated operating voltage: AC 220V/380V

Rated current: 0.5A~60A

Capacity of contacts: 1 group of NC contacts,

AC 220V 5A

Releasing grade: 10A 3P

With over-load and break phase protective

function

www.peopleelectric.com 046

RHQ-S-C Series Motor Synthetical Protector

Confirms to: G14048.4

Rated operating voltage: AC 220V/380V

Rated current: 0.5A~400A

Capacity of contacts: 1 group of NC contacts,

AC 220V 5A

Releasing grade: 10A 3P

With over-load and break phase protective

function

XJ Series Break Phase and Phase-Sequence Protective Controller

Confirms to: G14048.5

Rated operating voltage: AC 380V 50/60Hz

Output of contacts: 1NO, 1NC

Capacity of contacts: AC 250V 5A (Resistance)

XJ01 Series Auto-Coupling ReducedVoltage Starter

Confirms to: GB14048.4

Frame size: 30, 75, 115, 190, 300, 400

Rated power: 14kW~400kW

Rated current: 28A~800A

Operating voltage: 380V/three phase

Suited motor: squirrel-cage three phase AC

asynchronous motor

Installation mode: box type structure floor install

JJ1 Series Auto-Coupling ReducedVoltage Starter

Confirms to: GB14048.4

Frame size: 30, 75, 115, 190, 300, 400

Rated power: 14kW~400kW

Rated current: 28A~800A

Operating voltage: 380V/three phase

Suited motor: squirrel-cage three phase AC

asynchronous motor

Installation mode: box type structure floor install

QX1 Series Star-Delta Starter

Confirms to: GB14048.3

Frame size: 13, 13N, 13

Rated power: 13kW~30kW

Rated frequency: 50/60Hz

Operating voltage: 380V/three phase

QX4 Series Star-Delta Starter

Confirms to: GB14048.4

Frame size: 17, 30, 55, 75

Rated power: 13kW~75kW

Rated current: 28A~85A

Operating voltage: 380V/three phase

Suited motor: squirrel-cage three phase AC

asynchronous motor Installation mode: box type structure floor or

wall type install

QJX2 Series Star-Delta Starter

Confirms to: GB14048.4

Rated operating current: 12A~95A

Rated insulation voltage: 660V

Control voltage of coil: AC 24V/36V/48V/110V/127V/ 220V/380V/440V/660V

RDQ12 Series Electromagnetic Starter

Confirms to: GB14048.4

Rated operating current: 10A~150A

Rated insulation voltage: 380V

Control voltage of coil: AC 24V/36V/48V/110V/127V/ 220V/380V/440V/660V

Control Components

Page 19: 6-Control Components

047 www.peopleelectric.com

RDQ20 Series Electromagnetic Starter

Confirms to: GB14048.4

Rated operating current: 10A~150A

Rated insulation voltage: 380V

Control voltage of coil: AC 24V/36V/48V/110V/127V/ 220V/380V

QCX5 Series Electromagnetic Starter

Confirms to: GB14048.4

Rated operating current: 9A~40A

Rated insulation voltage: 660V

Control voltage of coil: AC 24V/36V/48V/110V/127V/ 220V/380V/440V/660V

QCX8 Series Electromagnetic Starter

Confirms to: GB14048.4

Rated operating current: 9A~85A

Rated insulation voltage: 660V

Control voltage of coil: AC 24V/36V/48V/110V/127V/ 220V/380V/440V/660V

QZ610 Series Motor Protector

Confirms to: GB14048.4

Rated operating current: 10A~40A

Rated voltage: AC380V

RDB7 Series Variable Frequency Device

Confirms to: GB12668.2

Rated voltage: single phase 220V, three phase 380V

Power of motor: 0.75kW~315kW

Installation mode: wall type and cabinet type

RDI67 Series Variable Frequency Device

Confirms to: GB12668.2

Rated voltage: single phase 220V, three phase 380V

Power of motor: 0.75kW~315kW

RDJR6 Series Soft Starter

Confirms to: GB14048.6

Frame size: 75, 200, 315, 450

Rated power: 5.5kW~450kW

Rated current: 22A~900A

Operating voltage: 400V/three phase

Suited motor: squirrel-cage three phase AC

asynchronous motor

Installation mode: wall type installation

RDRQ1 Series Soft Starter

Confirms to: GB14048.6

Frame size: 37, 75, 200, 315, 450

Rated power: 11kW~450kW

Rated current: 22A~900A

Operating voltage: 400V/three phase

Suited motor: squirrel-cage three phase AC

asynchronous motor

Installation mode: wall type installation

www.peopleelectric.com 048

XJ01E Series Soft Starter ControlCabinet

Confirms to: GB14048.6

Frame size: 40, 75, 200, 315, 450

Rated power: 14kW~450kW

Rated current: 28A~1000A

Operating voltage: 400V/three phase

Suited motor: squirrel-cage three phase AC

asynchronous motor

Installation mode: cabinet type structure floor

installation

JD Series Electronic Speed Regulating Device

JD6A Series Electronic SpeedRegulating Device

KT10 Series Cam Controller

KT12 Series Cam Controller KT14 Series Cam Controller

KTJ6 Series Cam ControllerKTJ1 Series Cam Controller

Rated operating voltage: AC 220V

Rated output current: DC 90V 3.15A/5A/5A/8A

Controllable motor power: 0.55kW~90kW

Suited motor is electromagnetic speed-

regulating motor

Rated operating voltage: AC 220V

Rated output current: DC 90V 3.15A/5A/5A/8A

Controllable motor power: 0.55kW~90kW

Suited motor is electromagnetic speed-

regulating motor

Rated voltage: AC 380V

Rated frequency: 50/60Hz

Rated current: 25A, 60A

Operation frequency: 600 times/h

Mechanical life: 1.5 *10 times

Rated voltage: AC 380V

Rated frequency: 50/60Hz

Rated current: 25A, 60A

Operation frequency: 600 times/h

Rated voltage: AC 380V

Rated frequency: 50/60Hz

Rated current: 25A, 60A

Operation frequency: 600 times/h

Mechanical life: 1.5 *10 times

Rated voltage: AC 380V

Rated frequency: 50/60Hz

Rated current: 50A, 80A

Operation frequency: 600 times/h

Rated voltage: AC 380V

Rated frequency: 50/60Hz

Rated current: 25A, 60A

Control Components

Page 20: 6-Control Components

047 www.peopleelectric.com

RDQ20 Series Electromagnetic Starter

Confirms to: GB14048.4

Rated operating current: 10A~150A

Rated insulation voltage: 380V

Control voltage of coil: AC 24V/36V/48V/110V/127V/ 220V/380V

QCX5 Series Electromagnetic Starter

Confirms to: GB14048.4

Rated operating current: 9A~40A

Rated insulation voltage: 660V

Control voltage of coil: AC 24V/36V/48V/110V/127V/ 220V/380V/440V/660V

QCX8 Series Electromagnetic Starter

Confirms to: GB14048.4

Rated operating current: 9A~85A

Rated insulation voltage: 660V

Control voltage of coil: AC 24V/36V/48V/110V/127V/ 220V/380V/440V/660V

QZ610 Series Motor Protector

Confirms to: GB14048.4

Rated operating current: 10A~40A

Rated voltage: AC380V

RDB7 Series Variable Frequency Device

Confirms to: GB12668.2

Rated voltage: single phase 220V, three phase 380V

Power of motor: 0.75kW~315kW

Installation mode: wall type and cabinet type

RDI67 Series Variable Frequency Device

Confirms to: GB12668.2

Rated voltage: single phase 220V, three phase 380V

Power of motor: 0.75kW~315kW

RDJR6 Series Soft Starter

Confirms to: GB14048.6

Frame size: 75, 200, 315, 450

Rated power: 5.5kW~450kW

Rated current: 22A~900A

Operating voltage: 400V/three phase

Suited motor: squirrel-cage three phase AC

asynchronous motor

Installation mode: wall type installation

RDRQ1 Series Soft Starter

Confirms to: GB14048.6

Frame size: 37, 75, 200, 315, 450

Rated power: 11kW~450kW

Rated current: 22A~900A

Operating voltage: 400V/three phase

Suited motor: squirrel-cage three phase AC

asynchronous motor

Installation mode: wall type installation

www.peopleelectric.com 048

XJ01E Series Soft Starter ControlCabinet

Confirms to: GB14048.6

Frame size: 40, 75, 200, 315, 450

Rated power: 14kW~450kW

Rated current: 28A~1000A

Operating voltage: 400V/three phase

Suited motor: squirrel-cage three phase AC

asynchronous motor

Installation mode: cabinet type structure floor

installation

JD Series Electronic Speed Regulating Device

JD6A Series Electronic SpeedRegulating Device

KT10 Series Cam Controller

KT12 Series Cam Controller KT14 Series Cam Controller

KTJ6 Series Cam ControllerKTJ1 Series Cam Controller

Rated operating voltage: AC 220V

Rated output current: DC 90V 3.15A/5A/5A/8A

Controllable motor power: 0.55kW~90kW

Suited motor is electromagnetic speed-

regulating motor

Rated operating voltage: AC 220V

Rated output current: DC 90V 3.15A/5A/5A/8A

Controllable motor power: 0.55kW~90kW

Suited motor is electromagnetic speed-

regulating motor

Rated voltage: AC 380V

Rated frequency: 50/60Hz

Rated current: 25A, 60A

Operation frequency: 600 times/h

Mechanical life: 1.5 *10 times

Rated voltage: AC 380V

Rated frequency: 50/60Hz

Rated current: 25A, 60A

Operation frequency: 600 times/h

Rated voltage: AC 380V

Rated frequency: 50/60Hz

Rated current: 25A, 60A

Operation frequency: 600 times/h

Mechanical life: 1.5 *10 times

Rated voltage: AC 380V

Rated frequency: 50/60Hz

Rated current: 50A, 80A

Operation frequency: 600 times/h

Rated voltage: AC 380V

Rated frequency: 50/60Hz

Rated current: 25A, 60A

Control Components

Page 21: 6-Control Components

049 www.peopleelectric.com

KTJ15 Series Cam Controller

Rated voltage: AC 380V

Rated frequency: 50/60Hz

Rated current: 32A, 63A

Mechanical life: 3 *10 times

LK1 Series Cam Controller

Rated voltage: AC 380V

Rated frequency: 50/60Hz

Rated current: 10A

LK4 Series Cam Controller

Rated voltage: AC 380V, DC440V

Rated frequency: 50/60Hz

Rated current: 10A

Operation frequency: 1200 times/h

LK5 Series Cam Controller

Rated voltage: AC 380V, DC440V

Rated frequency: 50/60Hz

Rated current: 10A

RDCPS Series Control and ProtectiveSwitch

Confirms to: GB14048.9

Frame size: 45, 125A

Rated operating current: 0.4A~125A

Rated insulation voltage: 690V

Control voltage of coil: AC 220V/380V

Number of pole: 3P, 4P

RDCPSD Series Double SpeedController

Confirms to: GB14048.9

Rated operating current: 0.4A~125A

Rated insulation voltage: 690V

Control voltage of coil: AC 220V/380V

Number of pole: 3P

RDCPSJ Series Star-Delta Controller

Confirms to: GB14048.9

Rated operating current: 0.4A~125A

Rated insulation voltage: 690V

Control voltage of coil: AC 220V/380V

Number of pole: 3P