Daikin McQuay Pathfinder™ Air Cooled Chiller Screw Compressor 3 Circuit Unit Revision 00 (Code 62) Model: AWS Sizes: 400 - 550 Vintage: C R134a 60 Hz Replacement Parts List No. 700028300 New 08/2013 To find your Daikin McQuay parts distributor, call 1-800-377-2787 or visit www.DaikinMcQuay.com

7000283 DAIKIM AWS400CTS27

Embed Size (px)

DESCRIPTION

Chiller de 400 toneladas de refrigeracion

Citation preview

  • Daikin McQuay Pathfinder Air Cooled Chiller

    Screw Compressor3 Circuit

    Unit Revision 00 (Code 62)Model: AWS

    Sizes: 400 - 550 Vintage: C

    R134a60 Hz

    Replacement Parts List No. 700028300New 08/2013

    To find your Daikin McQuay parts distributor, call 1-800-377-2787 or visit www.DaikinMcQuay.com

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 2

    ContentsParts List Revision History.................................................................................................................................. 3Nomenclature Serial Number .............................................................................................................................................. 4 Unit Model Number- Dataplate .................................................................................................................... 4 Unit Model Number- Complete ............................................................................................................... 5 - 6Electrical Legend ..........................................................................................................................................7 - 11Unit Layout ....................................................................................................................................................... 12Refrigeration Section Compressor Charts .................................................................................................................................... 13 Compressors .............................................................................................................................................. 14 Compressor Components .......................................................................................................................... 15 Suction Lines ...................................................................................................................................... 16 - 17 Liquid Injection Lines .......................................................................................................................... 18 - 19 Discharge Lines .................................................................................................................................. 20 - 21 Liquid Lines ......................................................................................................................................... 22 - 26 Condenser Coils and Fans ........................................................................................................................ 27 Fan Totals per Unit ..................................................................................................................................... 28 Evaporator Diagram ................................................................................................................................... 29 Packaged Unit Evaporator Assemblies and Remote Evaporator Kits ........................................................ 30 Evaporator Components ............................................................................................................................ 31 Remote Evaporator Refrigeration Kits ....................................................................................................... 32Unit Panels ................................................................................................................................................ 33 - 34Coil Grilles ........................................................................................................................................................ 35Base Grilles ...................................................................................................................................................... 36Coil Louvers...................................................................................................................................................... 37Base Louvers............................................................................................................................................. 38 - 40Controls Units with Wye-Delta or Solid State Starter (Code 9 = WD, SS) Control Side Detail ............................................................................................................................... 41 Control Side Components ................................................................................................................... 42 Power Side Detail ......................................................................................................................... 43 - 45 Power Side Components .............................................................................................................. 46 - 51 Units with VFD Starters (Code 9 = VE or VF) Control Side Detail ........................................................................................................................ 52 - 53 Control Side Components ............................................................................................................ 54 - 56 Power Side Detail ......................................................................................................................... 57 - 59 Power Side Components .............................................................................................................. 60 - 62 Control Box Exhaust and Intake Fans ................................................................................................. 63 Terminal Box .............................................................................................................................................. 64Accessories Isolator Kits ......................................................................................................................................... 65 - 72 Flow Switch ................................................................................................................................................ 73 Sound Enclosure Kit .................................................................................................................................. 73 Alarm Bell ................................................................................................................................................ 73 Inlet Strainer ............................................................................................................................................... 73 Field-Installed Fan VFD Kits ...................................................................................................................... 74 High Ambient Exhaust Fan Kit ................................................................................................................... 74 Rapid Restore ............................................................................................................................................ 74 Emergency Stop Switch Kit ........................................................................................................................ 74 115V Outlet Kit ........................................................................................................................................... 74 Liquid Injection Kit ...................................................................................................................................... 74 D-Net Kit ................................................................................................................................................ 74 Grille and Louver Kits .......................................................................................................................... 75 - 78 BACnet MS/TP Communications Module .................................................................................................. 79 BACnet with IP/Ethernet ............................................................................................................................ 79 MODBUS Communications Module ........................................................................................................... 79 LonMark Communications Module ............................................................................................................ 79 Remote Display Kit .................................................................................................................................... 79

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 3

    Revision Date Description NEW 08/2013 NEW

    Parts List Revision History

    McQuay International, 13600 Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN 55440 (763) 553-5330

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 4

    Nomenclature

    AWS 400 C T S 27Unit Model Number- Dataplate

    Unit Type: AWS= Air- Cooled Screw Compressor Chiller

    Nominal Tonnageex. 400= 400 Tons

    Vintage

    Number of Compressors (circuits)T= 3

    STN U 13 10 038Plant IdentificationSTN = Staunton, VA

    Year of Manufacture13= 201314= 2014

    etc.

    U= Unit

    Serial Number (build sequence)Month of Manufacture01= January02= February03= March04= April05= May06= June

    07= July08= August09= September10= October11= November12= December

    Serial Number

    PlatformS= Standard Efficiency H= High Efficiency

    Voltage27= 460/60/346= 380/60/337= 575/60/3

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 5

    AWS 400C T SE NN ST S A WD Y 27 WN V N N N LM N G Y N N VL S JCode 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

    L F G ND YNNNNNNN0000000N N NNYNNNNNNNN0000000000000000000Code 26 27 28 29 30- 36 37 38- 45

    NomenclatureUnit Model Number- Complete

    ENDSUDPLYNNNNNNNNNNNRA1D00 NN M 6 NN Y S 0BCode 46-55 56 57 58 59 60 61 62

    02 Size (in nominal tons), C Vintage

    03 Number of Compressors T= 3

    04 Platform SE= Package- Std Eff SM= Remote Evap- Std Eff HE= Package- High Eff HM= Remote Evap- High Eff PE= Package- Prem Eff PM= Remote Evap- Prem Eff

    05 Construction NN= Standard

    06 Sound ST= Standard Sound LN= Low Noise- Sound Enclosure SR= Sound Reduction

    07 Unit Operation S= Standard (40 - 60 F LWT) A= Lower Operation (34 - 39 F LWT) B= Brine Operation (20 - 33 F LWT)

    08 Condenser Coil Fins A= Aluminum Fin (Standard) B= Aluminum Fin w/Prefab Black Fin Coating C= Copper Fin E= Aluminum Fin w/Electro Fin Coating F= Copper Fin w/Electro Fin Coating

    09 Compressor Starter WD= Wye- Delta w/Compressor Overloads SS= Solid State VF= VFD without EMI Filter VE= VFD with EMI Filter

    10 Always Y

    11 Voltage 27= 460/60/3 12= 208/60/3 29= 230/60/3 46= 380/60/3 37= 575/60/3

    12 Power Connection PC= Single Point Power Block & Circuit Breakers DC= Single Point Disconnect & Circuit Breakers DH= High Short Circuit Current Rating + DC WN= Multiple Point Disconnect- No Circuit Breaker WH= High Short Circuit Current Rating + WN

    13 Phase Voltage V= Phase & Under/Over Voltage Protection w/LED N= None

    14 Meters N= None E=Emergency Stop on Door A= Unit Amp & Volt Meters B= Emerg. Stop, Amp & Volt

    15 Control Box Ambient N= None H= With Exhaust Fans (High125F Max) M= With Exhaust Fans (Medium1118F Max)

    16 Compressor Capacitor N= None C= Power Correction Capacitors

    17 Communication NN= None NA= D-Net LN= LonMark LA= D-Net & LonMark MN= Mod Bus MA= D-Net & ModBus BN= BACnet w/ MSTP BA= D-Net & BACnet MSTP EN= BACnet w/ IP EA= D-Net & BACnet IP

    18 Display Options N= On Controller Only U= Unit Remote Display

    19 Ground Fault N= None G= Ground Fault Protection for the Unit

    20 Always Y

    21 Unit Options N= None C= 115V Convenience Outlet L= Slide Transducer B= 115V Convenience Outlet and Slide Transducer

    22 Water Flow N= None A= Water Flow Indication on Evaporator Only

    23 Evaporator Connection VL= Victaulic/ Left Hand VR= Victaulic/ Right Hand

    24 Evaporator Insulation S= Standard Evaporator- Single Layer D= Standard Evaporator- Double Insulation

    25 Motor Cooling J= With additional Liquid Injection Cooling S= Standard Cooling

    26 Fans L= Standard Low Noise Fan Motors

    400C= 400 Tons 525C= 525 Tons425C= 425 Tons 530C= 530 Tons450C= 450 Tons 550C= 550 Tons470C= 470 Tons 475C= 475 Tons 500C= 500 Tons

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 6

    27 Head Pressure F= Fantrol Only (35 F Minimum) V= VFD (First Fans/ Circuit) 28 Guards G= Condenser Coil Grilles Only F= Condenser Coil & Base Frame Grilles L= Condenser Coil Louvers B= Condenser Coil Louvers & Base Guard Louvers C= Condenser Coil Louvers and Base Frame Grilles

    29 Tubing Options ND= With Discharge Shut-Off Valve SD= With Suction and Discharge Shut-Off Valve LD= ND + Liquid Line Solenoid SL= SD + Liquid Line Solenoid

    30 Always Y

    31 Water Pump NN= None

    32 Pump Type NNNN= No Pump Package

    33 Pump Connection N= No Pump Package

    34 Pump Flow Actual 4 digit number based on conditions

    35 Total Head Actual 3 digit number based on conditions

    36 Pump Starter N= No Pump Package

    37 Pump Gauges N= None

    38 Pump Suction Valve N= None

    39 Pump Discharge Valve N= None

    40 Always Y

    41 Impeller Trim NNNN= No Pumps

    42 Expansion Tank NN= None

    43 Buffer Tank NN= None

    44 % of Glycol 000= None E**= Ethylene; **= % P**= Propylene; **= %

    45 Pump Number All 0's= None

    46 Approvals D= ETL/CETL Approval, No AHRI, ASHRAE 90.1 E= ETL/CETL Approval, AHRI, ASHRAE 90.1 W= ETL/CETL Approval, AHRI, No ASHRAE 90.1 Z= ETL/CETL Approval, No AHRI, No ASHRAE 90.1

    NomenclatureUnit Model Number- Complete, Continued

    47 CRN- Evaporator 1= CRN- BC 2= CRN- Alberta 3= CRN- Saskatchewan 4= CRN- Manitoba 5= CRN- Ontario 6= CRN- Quebec 7= CRN- New Brunswick 8= CRN- Nova Scotia 9= CRN- P.E.I. U= CRN- Yukon 0= CRN- NewFoundland N= None

    48 Unit Start DSU= Domestic Start Up CSU= Canadian Start Up ISU= International- No Start Up Provided

    49 Standard Warranty DPL= Domestic 1st Year Standard CPL= Canadian 1st Year Standard Warranty TPN= International 1st Year Standard Warranty

    50 Always Y

    51 Extended Compressor Warranty NNNN= No Extended Compressor Warranty CPE*= Compressor Only- Parts Only (*= no. of years) CBE*= Compressor Only- Parts & Labor (*= no. of years)

    52 Always NNN

    53 Extended Unit Warranty NNNN= None EPE*= Ext. Unit- Parts Only (*= no. of years) EBE*= Ext. Unit- Parts & Labor (*= no. of years) DPE*= Ext. Unit w/Dual Pumps- Parts Only (*= no. of years) DBE*= Ext. Unit w/Dual Pumps- Parts & Labor (*= no. of years) SPE*= Ext. Unit w/Single Pump- Parts Only (*= no. of years) SBE*= Ext. Unit w/Single Pump- Parts & Labor (*= no. of years)

    54 Refrigerant Warranty NNN= None RA*= Refrigerant 134a Warranty (*= no. of years)

    55 Delayed Warranty Start D00= 0 months D**= Delayed Warranty Start (**= number of months)

    56 Always NN

    57 Brand Name D= DaikinMcQuay M= McQuay

    58 Ship S= Standard Ship R= Quick Ship

    59 Restart NN= Standard RR= Rapid Restore

    60 Always Y

    61 Misc. S= Standard Unit X= Special

    62 Major Unit Change Revision 00= No Revision

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 7

    Electrical Legend - Units with Wye Delta or SS Starter Sch. Sym. Description Location AC Alarm Control Control Side AM1 Ammeter Control Box Door BACnet Communication Module Control Side C101- 112 Fan Harness Connector Condenser Fan Section C201- 212 Fan Harness Connector Condenser Fan Section C301- 310 Fan Harness Connector Condenser Fan Section CC1, 2, 3 Controller Expansion Module Control Side CT11- CT33 Current Transformer Power Side D-NET D-NET AWM Communication Module Control Side DP-1, 2, 3 Condenser Pressure Cir. 1, 2, 3 Discharge Line- Circuit 1, 2, 3 EEXV1, 2, 3 Expansion Valve Controller Cir. 1, 2, 3 Control Side ESV-1, 2, 3 Economizer Solenoid Valve Cir. 1, 2, 3 Liquid Line- Circuit 1, 2, 3 EXV-1, 2, 3 Electronic Expansion Valve Cir. 1, 2, 3 Liquid Line- Circuit 1, 2, 3 F0-1, 2, 3 Control Circuit Switch Power Side F1, 2, 3 Compressor 1, 2, 3 Circuit Breaker Power Side F5-1, 2, 3 Thermal Overload Relay Power Side F10, 11, 12 Fuse Control Side F13 High Pressure Switch Cir. 1 Compressor 1 F23 High Pressure Switch Cir. 2 Compressor 2 F33 High Pressure Switch Cir. 3 Compressor 3 F59 Evaporator Heater Fuse Control Side F90 Thermostat Control Side F100 Fan Circuit Breaker Cir. 1 Power Side F112 Phase Volt Monitor Cir. 1 Power Side F116 Evaporator Flow Switch Evaporator Outlet F120 Transformer T1 Protection Power Side F130 Phase Volt Monitor Fuse Control Side F200 Fan Circuit Breaker 2 Power Side F212 Phase Voltage Monitor Cir. 2 Power Side F230 Phase Volt Monitor Fuse Cir. 2 Control Side F300 Fan Circuit Breaker 3 Power Side F312 Phase Voltage Monitor Cir. 3 Power Side F330 Phase Voltage Monitor Fuse Cir. 3 Control Side FC Fan Control Control Side FTB Exhaust Fan Terminal Block Power Side FTB1, 2, 3 Fan VFD Terminal Block Power Side FTB107 Fan Terminal Block Cir. 1 Power Side FTB110 Fan Terminal Block Cir. 1 Power Side FTB207 Fan Terminal Block Cir. 2 Power Side FTB210 Fan Terminal Block Cir. 2 Power Side FTB307 Fan Terminal Block Cir. 3 Power Side FU100, 200 Condenser Fan Fuse Power Side GFR1, 2, 3 Ground Fault Relay Cir. 1, 2, 3 Power Side GLG1, 2, 3 Main Power Ground Power Side K11 Emergency Stop Contactor Control Side K2B-1, 2, 3 Relay Control Side KLJ-1, 2, 3 Liquid Injection Relay 1, 2, 3 Control Side KM1-1 Compressor Contactor Power Side KM2-1 Compressor Contactor Power Side KM3-1 Compressor Contactor Power Side KM1-2 Compressor Contactor Power Side KM2-2 Compressor Contactor Power Side KM3-2 Compressor Contactor Power Side

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 8

    Sch. Sym. Description Location KM1-3 Compressor Contactor Power Side KM2-3 Compressor Contactor Power Side KM3-3 Compressor Contactor Power Side KM10-1, 2 , 3 Contactor Power Side KM101- 110 Fan Motor Contactor Power Side KM201- 210 Fan Motor Contactor Power Side KM301- 310 Fan Motor Contactor Power Side KT-1, 2, 3 Time Delay Relay Cir. 1, 2, 3 Control Side KT1-1, 2, 3 Relay Control Side LJV-1, 2, 3 Liquid Injection Solenoid Cir. 1, 2, 3 Liquid Injection Line LONmark Communication Module Control Side LP1, 2, 3 Low Pressure Switch 1, 2, 3 Compressor 1, 2, 3 LR1, 2, 3 Line Reactor Cir. 1, 2, 3 Power Side LSV-1, 2, 3 Liquid Line Solenoid Cir. 1, 2, 3 Liquid Line- Circuit 1, 2, 3 M1, 2, 3 Compressor Cir. 1, 2, 3 Base M10 Forced Ventilation Fan Switch Box End, Power Side M101- 112 Fan Motor Condenser Fan Section M201- 212 Fan Motor Condenser Fan Section M301- 310 Fan Motor Condenser Fan Section M5 Terminal Block Control Side MC1, 2, 3 Ground Bar Control Side Mod Bus Communication Module Control Side MP1, 2, 3 Motor Thermal Protection Control Side MPR1, 2, 3 Motor Protection Relay Cir. 1, 2, 3 Control Side MQ Terminal Block Control Side OP-1, 2, 3 Oil Pressure Cir. 1, 2, 3 Compressor 1, 2, 3 PD1, 2, 3 Power Distribution Block Power Side Q0 Unit ON - OFF Switch Control Side Q1 Switch Cir. 1 Control Side Q2 Switch Cir. 2 Control Side Q3 Switch Cir. 3 Control Side Q10 Disconnect Switch 1 Power Side Q11 Emergency Stop Switch Control Box Door Q12 Transformer Fuse Power Side Q20 Disconnect Switch 2 Power Side Q30 Disconnect Switch 3 Power Side Q101- 110 Fan MSP Power Side Q201- 210 Fan MSP Power Side Q301-310 Fan MSP Power Side R1, 2, 3 Compressor Crankcase Heater Cir. 1, 2, 3 Compressor 1, 2, 3 R5 Evaporator Heater Evaporator Shell REC 1 115V Outlet Control Side SC1, 2, 3 Terminal Block Control Side SL-1, 2, 3 Slide Indicator Cir. 1, 2, 3 Compressor 1, 2, 3 SP-1, 2, 3 Evap. Pressure Circuit 1, 2, 3 Suction Line- Circuit 1, 2, 3 SS1 Selection Switch for Voltmeter Control Box Door SS2 Selection Switch for Ammeter Control Box Door ST-1, 2, 3 Suction Temperature Cir. 1, 2, 3 Suction Line- Circuit 1, 2, 3 T1 120V Transformer Power Side T2 24V Transformer Control Side T20-1, 2, 3 Transformer Cir. 1, 2, 3 Control Side T21-1, 2, 3 Transformer Cir. 1, 2, 3 Control Side TBX1-1, 2, 3 Heater Terminal Block Control Side

    Electrical Legend - Units with Wye Delta or SS Starter

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 9

    Sch. Sym. Description Location UC Unit Control- MicroTech III Control Side VFD1, 2, 3 Fan VFD Power Side VM1 Volt Meter Control Box Door WAA Air Ambient Sensor Condenser Coil Header WD-1, 2, 3 Oil Discharge Temp. Sensor Cir. 1, 2, 3 Discharge Line- Circuit 1, 2, 3 WIE Evaporator Entering Water Temperature Evaporator Inlet WOE Evaporator Leaving Water Temperature Evaporator Outlet Y2A-1 Non-Modulating Slide Load Sol. Valve Cir. 1 Compressor 1 Y2A-2 Non-Modulating Slide Load Sol. Valve Cir. 2 Compressor 2 Y2A-3 Non-Modulating Slide Load Sol. Valve Cir. 3 Compressor 3 Y2B-1 Modulating Slide Load Solenoid Valve Cir. 1 Compressor 1 Y2B-2 Modulating Slide Load Solenoid Valve Cir. 2 Compressor 2 Y2B-3 Modulating Slide Load Solenoid Valve Cir. 3 Compressor 3 Y3A-1 Non-Mod. Slide Unload Sol. Valve Cir. 1 Compressor 1 Y3A-2 Non-Mod. Slide Unload Sol. Valve Cir. 2 Compressor 2 Y3A-3 Non-Mod. Slide Unload Sol. Valve Cir. 3 Compressor 3 Y3B-1 Mod. Slide Unload Solenoid Valve Cir. 1 Compressor 1 Y3B-2 Mod. Slide Unload Solenoid Valve Cir. 2 Compressor 2 Y3B-3 Mod. Slide Unload Solenoid Valve Cir. 3 Compressor 3 YT-1, 2, 3 Turbo Solenoid Valve Cir. 1, 2, 3 Compressor 1, 2, 3

    Electrical Legend - Units with Wye Delta or SS Starter

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 10

    Electrical Legend - Units with VFD Starter Sch. Sym. Description Location AC Alarm Control Control Side AM1 Ammeter Control Box Door C30 EXV-3 Connector Outside Back of Control Side C101- 112 Fan Harness Connector Condenser Fan Section C201- 212 Fan Harness Connector Condenser Fan Section C301- 310 Fan Harness Connector Condenser Fan Section CC1, 2, 3 Control Compressor Cir. 1, 2, 3 Control Side D-NET D-Net AWM Communication Module Control Side DP-1, 2, 3 Condenser Pressure Cir. 1, 2, 3 Discharge Line- Circuit 1, 2, 3 EEXV1, 2, 3 Expansion Valve Controller Cir. 1, 2, 3 Control Side EMI-1, 2, 3 Electromagnetic Interference Filter 1, 2, 3 Power Side ESV-1, 2, 3 Economizer Solenoid Valve Cir. 1, 2, 3 Liquid Line- Circuit 1, 2, 3 EXV-1, 2, 3 Electronic Expansion Valve Cir. 1, 2, 3 Liquid Line- Circuit 1, 2, 3 F0-1, 2, 3 Crankcase Heater Fuses/ MSP Power Side F1, 2, 3 Compressor 1, 2, 3 Circuit Breaker Power Side F10 Exhaust Fan Fuse Control Side F11 Unit Controller Fuse Control Side F12 Outlet Fuse Control Side F13 High Pressure Switch Cir. 1 Compressor 1 F23 High Pressure Switch Cir. 2 Compressor 2 F33 High Pressure Switch Cir. 3 Compressor 3 F59 Evaporator Heater Fuse Control Side F90 Thermostat Control Side F100 Fan Circuit Breaker Cir. 1 Control Side F116 Evaporator Flow Switch Evaporator Outlet F120,220 Transformer T1 Protection Power Side F130 Phase Volt Monitor Fuse Control Side F200 Fan Circuit Breaker Cir. 2 Control Side F300 Fan Circuit Breaker Cir. 3 Control Side FC Fans Control Control Side FTB107 Fan Terminal Block Cir. 1 Control Side FTB110 Fan Terminal Block Cir. 1 Control Side FTB207 Fan Terminal Block Cir. 2 Control Side FTB210 Fan Terminal Block Cir. 2 Control Side FTB307 Fan Terminal Block Cir. 3 Control Side GFR1, 2, 3 Ground Fault Relay Cir. 1, 2, 3 Control Side JFU1, 2, 3 HSCR Fuse 1, 2, 3 Control Side K1, 2, 3 Compressor VFD Run Relay 1, 2, 3 Power Side K11 Emergency Stop Contactor Control Side K13 Mechanical Hi Pressure Relay & Contactor Control Side K23 Mechanical Hi Pressure Relay & Contactor Control Side K33 Mechanical Hi Pressure Relay & Contactor Control Side K36 Fan Stage Cir. 3 Control Side KLJ-1, 2, 3 Liquid Injection Relay 1, 2, 3 Control Side KM101- 110 Fan Motor Contactor Control Side KM201- 210 Fan Motor Contactor Control Side KM301- 310 Fan Motor Contactor Control Side LJV-1, 2, 3 Liquid Injection Solenoid Cir. 1, 2, 3 Liquid Injection Line 1, 2, 3 LP1, 2, 3 Low Pressure Switch 1, 2, 3 Compressor 1, 2, 3 LR1, 2, 3 Line Reactor Cir. 1, 2, 3 Control Side

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 11

    Electrical Legend - Units with VFD Starter Sch. Sym. Description Location LSV-1, 2, 3 Liquid Line Solenoid Cir. 1, 2, 3 Liquid Line- Circuit 1, 2, 3 M1, 2, 3 Compressor Cir. 1, 2, 3 Base M10 Forced Ventilation Outside Wall of Power Side M11 Intake Fan Outside Wall of Control Side M12 Exhaust Fan Control Box Left Door M101- 112 Fan Motor Condenser Fan Section M201- 212 Fan Motor Condenser Fan Section M301- 310 Fan Motor Condenser Fan Section MP1, 2, 3 Motor Thermal Protection Control Side MPR1, 2, 3 Motor Protection Relay Cir. 1, 2, 3 Control Side OP-1, 2, 3 Oil Pressure Cir. Cir. 1, 2, 3 Compressor 1, 2, 3 PD1, 2, 3 Power Disribution Block Power Side Q0 Unit ON - OFF Switch Control Side Q1 Pump Down Switch Cir. 1 Control Side Q2 Pump Down Switch Cir. 2 Control Side Q3 Pump Down Switch Cir. 3 Control Side Q10, 20, 30 Main Power Block or Disconnect Switch Power Side Q11 Emergency Stop Switch Control Box Left Door Q12 Automatic Circuit Breaker T1 Transformer Q101- 110 Fan MSP Control Side Q201- 210 Fan MSP Control Side Q301 - 310 Fan MSP Control Side R1, 2, 3 Compressor Crankcase Heater Cir. 1, 2, 3 Compressor 1, 2, 3 R5 Evaporator Heater Evaporator Shell REC 1 115V Outlet Control Side SP-1, 2, 3 Evap. Pressure Circuit 1, 2, 3 Suction Line- Circuit 1, 2, 3 SS1 Selection Switch 1 Voltmeter SS2 Selection Switch 2 Ammeter ST-1, 2, 3 Suction Temperature Cir. 1, 2, 3 Suction Line- Circuit 1, 2, 3 T1 115V Transformer Power Side T2 24V Transformer Control Side T20-1, 2, 3 Transformer Cir. 1, 2, 3 Control Side T21-1, 2, 3 Transformer Cir. 1, 2, 3 Control Side UC Unit Control- MicroTech III Control Side VFD1, 2, 3 Fan VFD / SpeedTrol Control Side Left Wall VFD-1 Compressor VFD 1 Power Side VFD-2 Compressor VFD 2 Power Side VFD-3 Compressor VFD 3 Power Side VM1 Volt Meter Switch Box Door WAA Air Ambient Sensor Condenser Coil Header WD-1, 2, 3 Oil Discharge Temp. Sensor Cir. 1, 2, 3 Discharge Line- Circuit 1, 2, 3 WIE Evaporator Entering Water Temperature Evaporator Inlet WOE Evaporator Leaving Water Temperature Evaporator Outlet

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 12

    Unit Layout(Unit Size 400CTS Shown)

    10

    1

    8

    2

    Ref. No. Description Location 1 Compressors Refrigeration Section 2 Tubing (suction, discharge, liquid injection) Refrigeration Section 3 Liquid Line and Economizer Refrigeration Section 7 Evaporator Refrigeration Section 8 Condenser Coil Refrigeration Section 9 Condenser Fans Refrigeration Section 10 Unit Switch Box/Control Panel * Controls Section 12 Compressor Terminal Box Controls Section

    9

    7

    9 9 9 99 9 9

    12

    * Control Panel size may vary.

    99 9

    3

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 13

    Unit Size Std Eff. High Eff

    400 B -- 425 B -- 450 E B 470 E -- 475 -- B 500 E E 525 D -- 530 -- E 550 D --

    Compressor, Circuit 1

    Refrigeration SectionCompressor Charts

    See next page for Compressor part numbers.

    Standard Efficiency: Code 4 = S*; High Efficiency: Code 4 = H*

    Unit Size Std Eff. High Eff

    400 B -- 425 B -- 450 E B 470 E -- 475 -- B 500 E E 525 D -- 530 -- E 550 D --

    Compressor, Circuit 2

    Unit Size Std Eff. High Eff

    400 B -- 425 E -- 450 B B 470 E -- 475 -- E 500 D B 525 E -- 530 -- E 550 D --

    Compressor, Circuit 3

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 14

    Compressor B 380V (units w/ VFD Starters) 332529382D 380V (units w/o VFD Starters) 332529282D 460V (units w/ VFD Starters) 332529362D 460V (units w/o VFD Starters) 332529262D 575V 332529267D

    Compressor D 380V (units w/ VFD Starters) 332529384D 380V (units w/o VFD Starters) 332529284D 460V (units w/ VFD Starters) 332529364D 460V (units w/o VFD Starters) 332529264D 575V 332529269D

    Compressor E 380V (units w/ VFD Starters) 332529383D 380V (units w/o VFD Starters) 332529283D 460V (units w/ VFD Starters) 332529363D 460V (units w/o VFD Starters) 332529263D 575V 332529268D

    Units with VFD Starters: Code 9 = VE, VFUnits without VFD Starters: Code 9 = WD or SS

    Refrigeration SectionCompressors

    See previous page for Compressor Charts.

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 15

    Ref. Sch. Description Compressor Compressor Compressor Qty No. Sym. B D E per compr

    2 R1,2,3 Compressor Heater, 380V 735041266 735041266 735041266 1 2 R1,2,3 Compressor Heater, 460V 735041267 735041267 735041267 1 2 R1,2,3 Compressor Heater, 575V 735041268 735041268 735041268 1 2A Well- Heater 300043894 300043894 300043894 1 2B Bushing- Heater 132010016 132010016 132010016 1 10 F13,23,33 Switch- High Pressure Control, 290 psi 073074009 073074009 073074009 1 11 OP1, 2, 3 Transducer- Oil Pressure, 0 to 30 bar 10000109562 10000109562 10000109562 1 13 Relief Valve 735045859 735045859 735045859 1 13A Elbow- Relief Valve 10000108772 10000108772 10000108772 1 14 SL1, 2, 3 Transducer- Slide Indicator (C21= L, B) 330591103 330591103 330591103 1 15 Discharge Shut-Off Valve 10000107037 10000107037 10000107037 1 50 Isolator, Compr. Mounting 10000107142 10000107046 10000107046 4 51 Screw, M8 x 2.5 C101 330821929 330821929 330821929 8 52 Washer, Plain, .312 040500322 040500322 040500322 8 53 Washer, Lock, .500 048164814 048164814 048164814 4 54 Screw, M12 x 1.75 330821921 330821921 330821921 4 55 Washer, Lock, .312 048164810 048164810 048164810 8 60 Y2*1-1,2,3 Valve, Solenoid- Load 1 1 1 60A Y3*1-1,2,3 Valve, Solenoid- Unload 1 1 1 60B YT-1,2,3 Valve, Solenoid- Turbo 1 1 1 NS Suction Gasket 070199140 070199140 070199140 1 NS Oil Filter 332115201 332115201 332115201 1 NS Well- Oil Temperature Sensor 118510358 118510358 118510358 1 NS Liq Injection Fitting- Compr (non-Economizer) 132010053 132010053 132010053 1 NS Liq Injection Fitting- Compr (with Economizer) 10000105095 10000105095 10000105095 1 NS Liq Injection Fitting- Rotolock to Copper 10000107074 10000107074 10000107074 1 NS Liq Injection O-Ring 070194971 070194971 070194971 1 NS Gasket, Economizer Block 88114-311 88114-311 88114-311 1 NS Kit, O-Rings and Gaskets 128810919 128810921 128810921 1

    Refrigeration SectionCompressor Components

    1 Solenoids are comprised of: Valve Body & Adapter p/n 132010102; Valve Coil p/n 131066074; Valve Support Gasket p/n 332130201.

    NS = Not Shown

    Circuit # 1 shown

    10

    11

    213

    14

    515053

    52

    13A

    54

    15

    60A 60

    60

    60B

    60A Y3B1YT1

    Y2B1

    Y3A1

    Y2A1

    R1F13

    SL1

    2A 2B

    See Compressor Charts to identify compressor.

    55

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 16

    Refrigeration SectionSuction Lines

    Piping configuration may vary.

    Suction LineCircuit #1 (Pkg'd Unit) with SuctionShut-off Valve

    102

    100

    104ST1

    Suction

    Suction LineCircuit #3 (Pkg'd Unit) with SuctionShut-off Valve

    Suction LineCircuit #2 (Pkg'd unit)with SuctionShut-off Valve 202

    200

    204 ST2

    702

    700

    704 ST3

    Suction LineCircuit #2(Remote Evap)

    Suction LineCircuit #1 (Remote Evap)

    Suction LineCircuit #3(Remote Evap)

    120

    102

    100

    300320

    302200

    220

    202

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 17

    Refrigeration SectionSuction Lines

    Ref Sch. Part Part No. Sym. Description Number Qty.

    Suction Line- Circuit #1 100 Valve- Relief 200 PSI 735045852 1

    102 Valve- Suction Shutoff (Packaged Units, Code 4 = SE, HE, PE) 073062120 1 102 Valve- Suction Shutoff (Remote Evap, Code 4 = SM,HM,PM) 332430701 1

    104 ST1 Sensor- Suction Temperature, Bent, 30 ft. (Packaged units only) 332519703 1 Sensor- Suct. Temp., Bent, 110 ft. (Remote Evap units only) 332519704 1

    120 Charge Valve, 0.37 x 0.37 (Remote Evap units only) 038689900 1

    NS Pressure Switch CL20- OP5 (Remote Evap units only) 073074010 1

    NS SP1 Transducer- Suction -1 to 7 bar 10000109563 1

    Suction Line- Circuit #2 200 Valve- Relief 200 PSI 735045852 1

    202 Valve- Suction Shutoff (Packaged Units, Code 4 = SE, HE, PE) 073062120 1 202 Valve- Suction Shutoff (Remote Evap, Code 4 = SM,HM,PM) 332430701 1

    204 ST2 Sensor- Suction Temperature, Bent, 30 ft. (Packaged units only) 332519703 1 Sensor- Suct Temp., Bent, 110 ft. (Remote Evap units only) 332519704 1

    220 Charge Valve, 0.37 x 0.37 (Remote Evap units only) 038689900 1

    NS Pressure Switch CL20- OP5 (Remote Evap units only) 073074010 1

    NS SP2 Transducer- Suction -1 to 7 bar 10000109563 1

    Suction Line- Circuit #3 300 Valve- Relief 200 PSI 735045852 1

    302 Valve- Suction Shutoff (Packaged Units, Code 4 = SE, HE, PE) 073062120 1 302 Valve- Suction Shutoff (Remote Evap, Code 4 = SM,HM,PM) 332430701 1

    304 ST3 Sensor- Suction Temperature, Bent, 30 ft. (Packaged units only) 332519703 1 Sensor- Suct Temp., Bent, 110 ft. (Remote Evap units only) 332519704 1

    320 Charge Valve, 0.37 x 0.37 (Remote Evap units only) 038689900 1

    NS Pressure Switch CL20- OP5 (Remote Evap units only) 073074010 1

    NS SP3 Transducer- Suction -1 to 7 bar 10000109563 1NS = Not Shown

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 18

    Liquid InjectionCircuit #1

    Refrigeration SectionLiquid Injection Lines

    311

    313309

    304302

    303

    411413 409

    404 402403

    Liquid InjectionCircuit #2

    LiquidInjection LJV2

    LJV1 Liquid InjectionCircuit #3

    811

    813809

    804

    802

    803

    LJV3

    Piping configuration may vary.

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 19

    Refrigeration SectionLiquid Injection Lines

    Ref Sch. Part Part No. Sym. Description Number Qty.

    Liquid Injection- Circuit #1 302 Fitting- Rotolock 10000107074 1 303 Valve- Schrader 071100801 1 304 LJV1 Valve- Solenoid 120V 331451002 1 309 Strainer 735030506 1 311 Valve- Ball 330286003 1 313 Cap- Valve 032943500 1

    Liquid Injection- Circuit #2 402 Fitting- Rotolock 10000107074 1 403 Valve- Schrader 071100801 1 404 LJV2 Valve- Solenoid 120V 331451002 1 409 Strainer 735030506 1 411 Valve- Ball 330286003 1 413 Cap- Valve 032943500 1

    Liquid Injection- Circuit #3 802 Fitting- Rotolock 10000107074 1 803 Valve- Schrader 071100801 1 804 LJV3 Valve- Solenoid 120V 331451002 1 809 Strainer 735030506 1 811 Valve- Ball 330286003 1 813 Cap- Valve 032943500 1

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 20

    508

    500501

    505

    504503

    DischargeCkt. 1

    509

    DP1

    WD1

    Refrigeration SectionDischarge Lines

    608605

    604603

    600 601

    609 DP2WD2

    DischargeCkt. 3

    908

    900901

    905

    904903

    909

    DP3

    WD3

    Piping configuration may vary.

    DischargeCkt. 2

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 21

    Refrigeration SectionDischarge Lines

    Ref Sch. Part Part No. Sym. Description Number Qty. Discharge Line- Circuit #1 500 Coupling 3.13 10000108703 1 501 Kit- Flange 4.12 735016406 1 503 Valve- Schrader 071100801 1 504 Core- Valve 026541100 1 505 DP1 Transducer- Discharge Pressure 0 to 30 bar 10000109562 1 508 Tube- Sensor 070228901 1 509 WD1 Sensor- Discharge Temperature, 20 ft. 193414602 1 NS Gasket- Discharge Shut-Off Valve 070199144 1

    Discharge Line- Circuit #2 600 Coupling 3.13 10000108703 1 601 Kit- Flange 4.12 735016406 1 603 Valve- Schrader 071100801 1 604 Core- Valve 026541100 1 605 DP2 Transducer- Discharge Pressure 0 to 30 bar 10000109562 1 608 Tube- Sensor 070228901 1 609 WD2 Sensor- Discharge Temperature, 20 ft. 193414602 1 NS Gasket- Discharge Shut-Off Valve 070199144 1

    Discharge Line- Circuit #3 900 Coupling 3.13 10000108703 1 901 Kit- Flange 4.12 735016406 1 903 Valve- Schrader 071100801 1 904 Core- Valve 026541100 1 905 DP3 Transducer- Discharge Pressure 0 to 30 bar 10000109562 1 908 Tube- Sensor 070228901 1 909 WD3 Sensor- Discharge Temperature, 20 ft. 193414602 1 NS Gasket- Discharge Shut-Off Valve 070199144 1NS = Not Shown

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 22

    Refrigeration SectionLiquid Lines- Standard Efficiency

    Packaged Units (Code 04= SE)

    119

    Ref Sch. Part Part Qty. No. Sym. Description Number per circuit 100 Valve- Schrader 071100801 3 101 Core- Valve 026541100 3 102 Cap- Valve 032943500 3 107 Valve- Charge .37 x .37 038689900 3 108 Valve- Ball 1.625 330286087 1 109 Bracket- Drier 10000101769 1 112 Shell- Filter Drier 071993505 1 113 Core- Filter Drier 330694401 4 114 Kit- Drier Gasket 074783601 2 115 Saddle- Sight Glass 330508705 1 116 Cap- Sight Glass 330508701 1 119 EXV1,2,3 Valve- Electronic Expansion 12V/6W 10000107041 1 124 LSV1,2,3 Valve- Liquid Line Solenoid C29= SD, SL 331451007 1

    Evaporator

    107 119107

    124

    Circuit #1

    102101100

    113

    108112

    114109100

    102

    101116

    115

    LSV1EXV1

    Piping configuration may vary.

    108

    107

    100102 101

    109

    113

    112

    114

    116

    115100

    102

    101

    Circuit #2

    109100

    102101

    116 115

    107

    124

    113112

    114

    108

    107

    102101100

    LSV2

    EXV2119

    124

    107

    100102 101

    Circuit #3

    LSV3

    EXV3

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 23

    Refrigeration SectionLiquid Lines- Standard Efficiency

    Remote Evaporator Units (Code 4= SM)

    Ref Sch. Part Part Qty. No. Sym. Description Number per circuit 100 Valve- Schrader 071100801 2 101 Core- Valve 026541100 2 102 Cap- Valve 032943500 2 103 Valve, Shut Off, 1.62 ODS x 1.62 ODS 032193508 1 107 Valve- Charge .37 x .37 038689900 2 NS EXV1, 2 Valve- Electronic Expansion 12V/6W 3 1 NS LSV1, 2 Valve- Liquid Line Solenoid 3 13 To identify these components on a unit with Remote Evaporator (Code 4= SM, HM or PM), see "Remote Evaporator Refrigeration Kits".

    102101100

    107

    103

    Circuit #1 Shown

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 24

    Refrigeration SectionLiquid Lines with Economizer- High Efficiency Units

    (Code 04= H*)

    116115

    From Economizer S4

    109

    112101

    201

    200

    100

    102101

    107

    119

    107

    124

    101

    100102

    21

    102

    101100

    Line Between Economizer and

    Compressor

    ESV_

    To Eva

    porator

    From E

    conom

    izer S2

    S1S4

    S2S3

    Economizer

    Connects To Evaporator

    To S1

    From C

    ondens

    er

    From L

    iquid Li

    ne Tee

    Liquid

    Line

    Tee

    To Comp

    ressor

    From

    Econom

    izer

    S4

    To Compressor

    Compressor Economizer Connection

    102

    101100

    102

    101100

    From

    Cond

    enser

    Representation of Circuit 1 is shown.Configuration may vary.

    (Circuits 2 & 3 have same components)

    Condenser to Economizer

    Economizer to Evaporator

    Circuit 1Circuit 2

    From ESV

    Equaliz

    ation

    Tube

    Evaporator

    6

    100 102 114

    108

    113

    TXV_

    EXV_

    LSV_

    208105

    105

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 25

    Refrigeration SectionLiquid Lines with Economizer- High Efficiency Units

    (Code 04= H*)

    Ref Sch. Part Part Qty. No. Sym. Description Number per circuit 1 ESV1,2,3 Valve- Economizer Solenoid 331451003 1 2 TXV1,2,3 Valve- Thermal Expansion see next page 1 6 Economizer- Brazed Plate see next page 1 100 Valve- Schrader 071100801 4 101 Core- Valve 026541100 4 102 Cap- Valve 032943500 4 105 Valve- Check see next page 2 107 Valve- Charge .37 x .37 038689900 3 108 Valve- Ball 1.625 330286087 1 109 Bracket- Drier 10000101769 1 112 Shell- Filter Drier 071993505 1 113 Core- Filter Drier 330694401 4 114 Kit- Drier Gasket 074783601 2 115 Saddle- Sight Glass 330508705 1 116 Cap- Sight Glass 330508701 1 119 EXV1,2,3 Valve- Electronic Expansion 12V/6W 10000107041 3 1 124 LSV1,2,3 Valve- Liquid Line Solenoid C29= SD, SL 331451007 3 1 200 Fitting- Compressor 10000105027 2 201 Fitting- Rotolock to Copper 10000107073 2 208 O-Ring 070194970 23 To identify these components on a unit with Remote Evaporator (Code 4= SM, HM or PM), see "Remote Evaporator Refrigeration Kits".

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 26

    Part Qty. Ref. # Description Number per circuit

    Economizer B 2 Thermal Expansion Valve 330692927 1 6 Economizer 10000107021 1 105 Check Valve 070300705 2

    Economizer D 2 Thermal Expansion Valve 330692928 1 6 Economizer 10000107024 1 105 Check Valve 070300705 2

    Refrigeration SectionLiquid Lines with Economizer- High Efficiency Units

    (Code 04= H*)

    Used with Used with Used with Unit Size Compressor 1 Compressor 2 Compressor 3

    450 B B B 475 B B D 500 D D B 530 D D D

    Use the chart above to determine the TXV / Economizer group . Use the chart below to identify the component part numbers.

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 27

    Refrigeration SectionCondenser Coils and Fans

    4

    2

    1

    3

    5

    Fan Detail

    50

    1 Mounted to Condenser Coil tubesheet behind the switch box.

    ***= Fan number 101 - 310.

    Ref Sch. Part Part Quantity No. Sym. Description Number

    1 Panel- Fan Deck 10000108765 1 per fan - see next page 2 Grille- Fan 10000107008 1 per fan 3 Bracket- Fan Motor 10000100048 1 per fan 4 Blade- Fan 10000107009 1 per fan 5 M*** Motor- Fan, 208/230V 1.4 HP 10000108871 1 per fan 5 M*** Motor- Fan, 380V 1.4 HP 10000108872 1 per fan 5 M*** Motor- Fan, 460V 1.4 HP 10000108873 1 per fan 5 M*** Motor- Fan, 575V 1.4 HP 10000108874 1 per fan

    50 WAA Sensor- Outdoor Air, 20 ft. 1 193414602 1 per unit

    Coils- Condenser Identitfy from diagram and Contact Daikin McQuay Parts

    F1C1

    F1C2 F1C4 F1C3

    F2C1

    F2C2 F2C4 F2C3

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 28

    Unit Std. Eff. High Eff. Size Ckt 1 Ckt 2 Ckt 3 Total Ckt1 Ckt 2 Ckt 3 Total

    400 7 7 8 = 22 -- -- -- -- 425 7 7 8 = 22 -- -- -- -- 450 8 8 8 = 24 8 8 8 = 24 470 8 8 8 = 24 -- -- -- -- 475 -- -- -- -- 8 8 10 = 26 500 8 8 10 = 26 10 10 8 = 28 525 10 10 8 = 28 -- -- -- -- 530 -- -- -- -- 10 10 10 = 30 550 10 10 10 = 30 -- -- -- --

    Refrigeration SectionFan Totals per Unit

    Standard Efficiency: Code 4 = S*, High Efficiency: Code 4 = H*

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 29

    Refrigeration SectionEvaporator Diagram

    Packaged and Remote Evaporators

    1

    5

    4A 47

    8

    6

    5

    WOE WIE

    F116

    218

    20

    12

    2A

    10 9

    Liquid Connection End

    Suction Connection End

    20

    14

    15 18

    19

    8A10 9

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 30

    Unit Sizes Left-Hand Evap Single Insulation Standard Efficiency Units (Code 4= SE) 400 332532602 425 332532602 450 332532602 470 332532603 500 332532603 525 332532603 550 332532603

    High Efficiency Units (Code 4= HE) 450 332532602 475 332532603 500 332532603 530 332532603

    Refrigeration SectionPackaged Unit Evaporator Assemblies and Remote Evaporator Kits

    Ref. No. 1: Packaged Unit Evaporator Assembly

    For Evaporator components see next page.

    Unit Sizes Left-Hand Evap Left-Hand Evap Single Insulation Double Insulation Standard Efficiency Units (Code 4 = SM) 400 334043413 334043513 425 334043413 334043513 450 334043413 334043513 470 334043414 334043514 500 334043414 334043514 525 334043414 334043514 550 334043414 334043514 High Efficiency Units (Code 4 = HM) 450 334043413 334043513 475 334043414 334043514 500 334043414 334043514 530 334043414 334043514

    Ref. No. 1: Remote Evaporator Kit

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 31

    Refrigeration SectionEvaporator Components

    Packaged and Remote Evaporators

    Ref Sch. Part Part No. Qty. No. Sym. Description

    2 Ferrule- Liquid E44070043 3 2A Flange- Liquid E44060009 3

    4 WIE Sensor- Evaporator Inlet, 60 ft. (Pkg'd Unit) 193414606 1 4A WOE Sensor- Evaporator Outlet, 60 ft. (Pkg'd Unit) 193414606 1 4 WIE Sensor- Evaporator Inlet, 110 ft. (Remote Evap) 193414611 1 4A WOE Sensor- Evap Outlet, 110 ft. (Remote Evap) 193414611 1

    5 Well- Sensor E44070058 2

    6 R5 Heater- Evaporator E44191111 1

    7 F116 Switch- Evaporator Flow 331796201 1 Cable- for Evap Flow Switch 330571403 1

    8 Gasket- Inlet Head E44136603 1 8A Gasket- Suction Head E44136603 1

    9 Gasket- Distributor E44136604 2 9 Gasket- Distributor E44136605 1

    10 O'Ring- Liquid E44130170 3

    12 Bolt- Liquid Ferrule E10154000 12

    14 Bolt- Suction Connection E14155000 12

    15 O'Ring- Suction E44130201 3

    18 Bolt- Head (M14- 16 x 1.5 x 130) E16151300 22 18 Bolt- Head (M16 x 1.5 x 145) E16151400 4 18 Bolt- Head (M16 x 1.5 x 70) E16157000 22

    19 Valve- Mini Ball, 0.50 NPT 071596201 1

    20 Pad- Vibration, 4" x 3.25" 735008725 4 NS Insulation 047662050 as needed

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 32

    Remote Evaporator Refrigeration KitsCode 4 = SM, HM

    Part Part Description Number Qty.

    Standard Efficiency Units (Code 4 = SM) Complete Kit 334043602 1 Valve- Electronic Expansion 10000107041 3 Cable, M12, 32.8 ft. 331409904 3 Tube- Sensor 070228901 3 Valve- Solenoid, 120V, 1.625 331451007 3 Saddle Adapter- Sight Glass, 1.625 330508705 3 Cap- Sight Glass 330508701 3 Shell- Filter Drier 071993505 3 Core- Filter Drier 070339101 12 Kit- Filter Drier Gasket 074783601 6 Valve- Charge, .37 x .37 038689900 3 Valve- Schrader 071100801 3 Core- Valve 026541100 3 Cap- Valve 032943500 3

    High Efficiency Units (Code 4 = HM) Complete Kit 334043612 1 Valve- Electronic Expansion 10000107041 3 Cable, M12, 32.8 ft. 331409904 3 Tube- Sensor 070228901 3 Valve- Solenoid, 120V, 1.625 331451007 3 Saddle Adapter- Sight Glass, 1.625 330508705 3 Cap- Sight Glass 330508701 3 Shell- Filter Drier 071993505 3 Core- Filter Drier 070339101 24 Kit- Filter Drier Gasket 074783601 12 Valve- Charge, .37 x .37 038689900 3 Valve- Schrader 071100801 3 Core- Valve 026541100 3 Cap- Valve 032943500 3

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 33

    Unit PanelsUnits with Wye-Delta or Solid State Starters (Code 9 = WD,SS)

    Ref Part Part Qty. No. Description Number 1 Panel, Front Top LH 333931001 1 2 Panel, Front Top RH 333931101 1 3 Panel, Front Side 10000101748 2 4 Bracket, Condenser Tie 332518601 1 5 Panel, Middle Side 332518801 2 6 Panel, Middle Top 332518701 2 7 Panel, Rear Top LH 10000101781 1 8 Panel, Rear Bottom LH 10000101757 1 9 Panel, Rear Top RH 10000101782 1 10 Panel, Rear Bottom RH 10000101759 1

    1

    2

    3

    45

    6

    78

    9

    10

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 34

    Unit PanelsUnits with VFD Starters (Code 9 = VE or VF)

    Ref Part Part Qty. No. Description Number 4 Bracket, Condenser Tie 332518601 1 5 Panel, Middle Side 332518801 2 6 Panel, Middle Top 332518701 2 7 Panel, Rear Top LH 10000101781 1 8 Panel, Rear Bottom LH 10000101757 1 9 Panel, Rear Top RH 10000101782 1 10 Panel, Rear Bottom RH 10000101759 1 21 Panel, Front Top LH Louvered 10000101942 1 22 Panel, Front Top RH Louvered 10000101943 1 23 Panel, Front Side Upper Louvered 10000101940 2 24 Panel, Front Side Lower LH 10000101941 1 25 Panel, Front Side Lower RH 10000101934 1

    9

    10

    21 22

    23

    4

    5

    6

    7

    8

    24

    25

    23

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 35

    16 Fan Unit shown

    1

    Ref Part Part Quantity No. Description Number 1 Grille- Coil 1 10000107007 1 per fan1 Each coil grille is attached using six (6) screws p/n 331578401.

    Std. High Unit Eff. Eff. Size Total Total Fans Fans 400 22 -- 425 22 -- 450 24 24 470 24 -- 475 -- 26 500 26 28 525 28 -- 530 -- 30 550 30 --

    Standard Efficiency: Code 4 = S*High Efficiency: Code 4 = H*

    Coil GrillesCode 28= G,F

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 36

    22 Fan Unit shown

    Ref Part Part Quantity No. Description Number 1 Grille- Base 1 10000108704 1 per fan 2 Grille- Left Hand Rear 2 10000108705 1 per unit 3 Grille- Right Hand Rear 2 10000108706 1 per unit 15 Grille- Front Sides 4 333931801 2 per unit 16 Grille- Front Center 4 333931802 1 per unit

    3

    1

    2

    1 Each Base Grille is attached using four (4) screws p/n 331578401.

    2 Each Rear Grille is attached using six (6) screws p/n 331578401.

    4 Each Front Grille is attached using (4) screws p/n 331578402. Front Grilles not used on units with VFD Starters.

    Base GrillesCode 28= F

    15

    16 15

    Std. High Unit Eff. Eff. Size Total Total Fans Fans 400 22 -- 425 22 -- 450 24 24 470 24 -- 475 -- 26 500 26 28 525 28 -- 530 -- 30 550 30 --

    Standard Efficiency: Code 4 = S*High Efficiency: Code 4 = H*

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 37

    Coil LouversCode 28=L, B, C

    Unit configuration will vary with number of fans.

    Ref Part Part Quantity No. Description Number 2 Louvered Panel- Coil 1 10000101793 1 per fan

    2

    1 Each coil louver is attached using six (6) screws p/n 331578401.

    Standard Efficiency: Code 4 = S*High Efficiency: Code 4 = H*

    Std. High Unit Eff. Eff. Size Total Total Fans Fans 400 22 -- 425 22 -- 450 24 24 470 24 -- 475 -- 26 500 26 28 525 28 -- 530 -- 30 550 30 --

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 38

    6

    4

    5 64 5 3

    2

    4

    46

    5

    5

    6

    Base LouversCode 28= B

    22-24 Fan Units

    3

    42

    5 6

    6

    5

    65

    5

    4

    5

    6

    4

    56

    6

    151615

    151615

    22 Fan Unit

    24 Fan Unit

    # of Fans screws Ref Part Part per No. Description Number 22 24 panel 2 2 Louvered Panel- Rear Bottom 10000101795 1 1 16 3 Louvered Panel- Rear Top 10000101796 1 1 10 4 Louvered Panel- Side 10000101797 9 14 6 5 Louvered Panel- Side 10000101798 6 5 10 6 Louvered Panel- Side 10000101799 6 5 10 7 Louvered Panel- Side 10000101792 1 14 15 Louvered Panel- Front Side 1 333931701 2 2 4 16 Louvered Panel- Front Center 1 333931702 1 1 41 Front Louvers not used on units with VFD Starters.

    2 Screw part number 331578402.

    Standard Efficiency: Code 4 = S*High Efficiency: Code 4 = H*

    7

    56

    4

    Std. High Unit Eff. Eff. Size Total Total Fans Fans 400 22 -- 425 22 -- 450 24 24 470 24 -- 475 -- 26 500 26 28 525 28 -- 530 -- 30 550 30 --

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 39

    6

    45

    64 5

    3

    2

    4

    46

    5

    5

    6

    Base LouversCode 28= B

    26-28 Fan Units

    3

    4 2

    4

    5

    6

    5

    65

    6

    5

    4

    45

    6

    1516

    15

    1516

    15

    26 Fan Unit

    28 Fan Unit

    # of Fans screws Ref Part Part per No. Description Number 26 28 panel 2 2 Louvered Panel- Rear Bottom 10000101795 1 1 16 3 Louvered Panel- Rear Top 10000101796 1 1 10 4 Louvered Panel- Side 10000101797 16 20 6 5 Louvered Panel- Side 10000101798 5 4 10 6 Louvered Panel- Side 10000101799 5 4 10 15 Louvered Panel- Front Side 1 333931701 2 2 4 16 Louvered Panel- Front Center 1 333931702 1 1 41 Front Louvers not used on units with VFD Starters.

    2 Screw part number 331578402.

    Standard Efficiency: Code 4 = S*High Efficiency: Code 4 = H*

    4

    6

    4

    64 5

    Std. High Unit Eff. Eff. Size Total Total Fans Fans 400 22 -- 425 22 -- 450 24 24 470 24 -- 475 -- 26 500 26 28 525 28 -- 530 -- 30 550 30 --

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 40

    6

    4 56 4

    5

    3

    2

    4

    46 5

    5

    6

    Base LouversCode 28= B

    30 Fan Units

    151615

    30 Fan Unit

    # of Fans screws Ref Part Part per No. Description Number 30 panel 2 2 Louvered Panel- Rear Bottom 10000101795 1 16 3 Louvered Panel- Rear Top 10000101796 1 10 4 Louvered Panel- Side 10000101797 20 6 5 Louvered Panel- Side 10000101798 5 10 6 Louvered Panel- Side 10000101799 5 10 15 Louvered Panel- Front Side 1 333931701 2 4 16 Louvered Panel- Front Center 1 333931702 1 41 Front Louvers not used on units with VFD Starters.

    2 Screw part number 331578402.

    Standard Efficiency: Code 4 = S*High Efficiency: Code 4 = H*

    4

    64 5

    Std. High Unit Eff. Eff. Size Total Total Fans Fans 400 22 -- 425 22 -- 450 24 24 470 24 -- 475 -- 26 500 26 28 525 28 -- 530 -- 30 550 30 --

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 41

    ControlsUnits with Wye-Delta or Solid State Starter (Code 9 = WD, SS)

    Control Side Detail

    For any control components not detailed or for unit specific controls, please contact Daikin McQuay Parts with the Control Box Serial Number and Control Box Part/GOI Number.

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 42

    Sch. Part Part Sym. Description Number Qty. AC Expansion Controller- Alarms 193407501 1 AWM Advanced Web Module, D-NET 2 193408502 1 CC1, 2, 3 Controller- Circuit 193407501 3 EEXV1, 2, 3 Controller- Expansion Valve Code 29= ND, SD 193441201 3 EEXV1, 2, 3 Controller- Expansion Valve Code 29= LD, SL 193441202 3 F10 Fuse, 10A 349937131 1 F11 Fuse, 10A 349937131 1 F12 Fuse, 10A 349937131 1 F59 Fuse- Evaporator Heater Protection, 2A 349937116 1 F90 Thermostat, Exhaust Fan 193418404 1 FC Expansion Controller- Fans 193407601 1 FC2 Expansion Controller- Fans 193407601 1 FC3 Expansion Controller- Fans 193407601 1 K11 Relay- Emergency Stop, 10A 3PDT 349934923 1 K2B-1, 2, 3 Relay, 10A DPDT 349934724 3 KLJ-1, 2, 3 Relay- Liquid Injection 193524116 3 KT-1, 2, 3 Relay 193524116 3 KT1-1, 2, 3 Time Delay- Starter 193524149 3 MP1, 2, 3 Motor Protector 330343901 3 MPR-1, 2, 3 Relay- Motor Protection 330278110 3 Q0 Switch- Unit Shut Off 802005045 1 Q1 Switch- Pumpdown Circuit #1 802005045 1 Q2 Switch- Pumpdown Circuit #2 802005045 1 Q3 Switch- Pumpdown Circuit #3 802005045 1 Q11 Switch- Emergency Stop 1 193441101 1 REC1 Receptacle 193466302 1 RR Rapid Restore Module (not shown, located next to AC Controller) 193407701 1 UC Controller- MicroTech III 193407301 1 T2 Transformer 24V 330386105 1 T20-1, 2, 3 Transformer- 120V to 24V 349937203 3 T21-1, 2, 3 Transformer- 120V to 24V 349937203 3 UC Battery for UC Controller 193409001 1

    Filter, Air Intake, 6 x 6 (not shown, located on bottom of control box) 193506701 1

    ControlsUnits with Wye-Delta or Solid State Starter (Code 9 = WD, SS)

    Control Side Components

    1 Not shown. Mounted through the door.

    2 This control board must be programmed in order to function correctly. When ordering a replacement, provide the unit model and

    serial number so that unit specific software can be loaded before shipment.

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 43

    ControlsUnits with Wye-Delta Starter (Code 9 = WD)

    Power Side DetailSingle Point Power Connection (Code 12= PC, DC, DH)

    For any control components not detailed or for unit specific controls, please contact Daikin McQuay Parts with the Control Box Serial Number and Control Box Part/GOI Number.

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 44

    ControlsUnits with Wye-Delta Starter (Code 9 = WD)

    Power Side DetailMulti-Point Power Connection (Code 12= WN, WH)

    For any control components not detailed or for unit specific controls, please contact Daikin McQuay Parts with the Control Box Serial Number and Control Box Part/GOI Number.

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 45

    ControlsUnits with Solid State Starter (Code 9 = SS)

    Power Side DetailSingle Point Power Connection (Code 12= PC, DC, DH)

    For any control components not detailed or for unit specific controls, please contact Daikin McQuay Parts with the Control Box Serial Number and Control Box Part/GOI Number.

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 46

    ControlsUnits with Wye-Delta or Solid State Starter (Code 9 = WD, SS)

    Power Side Components Sch. Part Part Sym. Description Number Qty. AM1 Ammeter with Gasket, 600A 1, 2 Code 14= A 193524137 1 AM1 Ammeter with Gasket, 1200A 1, 2 Code 14= A 193524138 1 AM1/SS2 Switch, Ammeter 1 193446102 1 CT 4,5,6 Current Transformer 2 (used with AM1 and VM1) 600:5A 193432206 3 CT 4,5,6 Current Transformer 2 (used with AM1 and VM1) 1200:5A 193432207 3 CT-GFR1, 2, 3 Sensor, Ground Fault 193461101 3 F112, 212, 312 Phase Voltage Monitor 208V, 230V, 460V 112022001 3 F112, 212, 312 Phase Voltage Monitor 575V 112022002 3 F120 Fuse- Control Transformer 208V 349937135 1 F120 Fuse- Control Transformer 230V 193594600 1 F120 Fuse- Control Transformer 460V 349937130 1 F120 Fuse- Control Transformer 575V 193594500 1 F130, 230, 330 Fuse- PVM (mounted on back side of control panel) 300046454 3 F0-1, 2, 3 MSP- Heater (Std SCCR, Code 12= PC, DC, WN) 349934026 3 F0-1, 2, 3 MSP- Heater (High SCCR, Code 12= DH, WH) 349934006 3 GFR1, 2, 3 Relay- Ground Fault 193466201 3 KM10-1, 2, 3 Relay, 10A 193454201 3 KM10-1, 2, 3 Line Shield, MMP 300041300 3 KM101 - 310 Fan Contactor, 18A (Std SCCR, Code 12= PC, DC, WN) 349932123 varies KM101 - 310 Fan Contactor, 25A (High SCCR, Code 12= DH, WH) 349932321 varies KM101 - 310 Link Module for Fan Contactors 349932922 varies LR1, 2, 3 Line Reactor 208/240V 349964941 3 LR1, 2, 3 Line Reactor 460V 300049960 3 LR1, 2, 3 Line Reactor 575V 349964952 3 M10 Control Box Exhaust Fan 193524129 1 M10 Guard, Exhaust Fan 193524127 1 Q12 Fuse, Midget 15A 349937035 1 Q101- 110 MSP- Fans Circuit #1 349934055 1/fan Q201- 210 MSP- Fans Circuit #2 349934055 1/fan Q301- 310 MSP- Fans Circuit #3 349934055 1/fan T1 Transformer- Control 208V:120V 038253975 1 T1 Transformer- Control 240V:120V 038253957 1 T1 Transformer- Control 380V:120V 349992907 1 T1 Transformer- Control 575V:120V 038253984 1 T1 Transformer Fuse Puller Kit 349955801 1 T1 Transformer Fuse Safety Cover 349955901 1 VFD1, 2, 3 Fan VFD 208/230V 193466001 3 VFD1, 2, 3 Fan VFD 380V, 460V 193466002 3 VFD1, 2, 3 Fan VFD 575V 193466003 3 VFD1, 2, 3 Remote Interface, Fan VFD 193466701 3 VFD1, 2, 3 LED Operator, Fan VFD 193466601 3 VM1 Volt Meter with Gasket: 0- 600V 1 Code 14= A 193524139 1 VM1/SS1 Switch, Voltmeter 1 193446602 11 Mounted on the outside front of the control panel door.

    2 To determine the correct Ammeter or Current Transformer part number, refer to the Device ID label found inside the unit control

    panel or contact Daikin McQuay Parts with the Control Box GOI number and/or the unit GO number and unit serial number.

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 47

    Sch. Sym. Part Description F1, 2, 3 Circuit Breaker- Compressor F100, 200, 300 Circuit Breaker- Fan FU100,200,300 Fuse- Condenser Fan Units with HSCCR: Code12= DH, WH JFU1, 2, 3 Fuse- Compressor Circuit Units with HSCCR: Code12= DH, WH PD1, 2, 3 Power Block- Main Units with Power Block: Code 12= PC Q10 Switch- Main Disconnect Units with Disc Switch: Code12= DC, DH, WN, WH Q20 Switch- Main Disconnect Only on Multi-Point units: Code12= WN, WH Q30 Switch-Main Disconnect Only on Multi-Point units: Code12= WN, WHTo insure proper replacement part number for any of the items above, refer to the Device ID label found inside the control panel or contact Daikin McQuay Parts with the Control Box GOI number and/or the unit GO number and unit serial num-ber.

    ControlsUnits with Wye-Delta or Solid State Starter (Code 9 = WD, SS)

    Power Side Components

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 48

    KM1-1, KM2-1 (Ckt 1); KM1-2, KM2-2 (Ckt 2); KM1-3, KM2-3 (Ckt 3)Compressor Contactors

    ControlsUnits with Wye-Delta Starter Panel (Code 09= WD)

    Power Side Components

    Unit Size Eff. 380V Ckt 1 460V Ckt 1 575V Ckt 1 400 Std 193524166 193524163 193524163 425 Std 193524166 193524163 193524163 450 Std 193524164 193524166 193524163 470 Std 193524164 193524166 193524163 500 Std 193524164 193524166 193524163 525 Std 193514701 193524164 193524166 550 Std 193514701 193524164 193524166

    450 High 193524166 193524163 193524163 475 High 193524166 193524163 193524163 500 High 193524164 193524166 193524163 530 High 193524164 193524166 193524163

    Unit Size Eff. 380V Ckt 2 460V Ckt 2 575V Ckt 2 400 Std 193524166 193524163 193524163 425 Std 193524166 193524163 193524163 450 Std 193524164 193524166 193524163 470 Std 193524164 193524166 193524163 500 Std 193524164 193524166 193524163 525 Std 193514701 193524164 193524166 550 Std 193514701 193524164 193524166

    450 High 193524166 193524163 193524163 475 High 193524166 193524163 193524163 500 High 193524164 193524166 193524163 530 High 193524164 193524166 193524163

    Unit Size Eff. 380V Ckt 3 460V Ckt 3 575V Ckt 3 400 Std 193524166 193524163 193524163 425 Std 193524164 193524166 193524163 450 Std 193524166 193524163 193524163 470 Std 193524164 193524166 193524163 500 Std 193514701 193524164 193524166 525 Std 193524164 193524166 193524163 550 Std 193514701 193524164 193524166

    450 High 193524166 193524163 193524163 475 High 193524164 193524166 193524163 500 High 193524166 193524163 193524163 530 High 193524164 193524166 193524163

    KM1-1, 2-1 (Circuit 1) 2 per circuit

    KM1-2, 2-2 (Circuit 2) 2 per circuit

    KM1-3, 2-3 (Circuit 3) 2 per circuit

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 49

    KM3-1 (Ckt 1); KM3-2 (Ckt 2); KM3-3 (Ckt 3)Compressor Contactors

    ControlsUnits with Wye-Delta Starter Panel (Code 09= WD)

    Power Side Components

    Unit Size Eff. 380V Ckt 1 460V Ckt 1 575V Ckt 1 400 Std 193593500 193593500 193593500 425 Std 193593500 193593500 193593500 450 Std 193524163 193593500 193593500 470 Std 193524163 193593500 193593500 500 Std 193524163 193593500 193593500 525 Std 193524163 193593500 193593500 550 Std 193524163 193593500 193593500

    450 High 193593500 193593500 193593500 475 High 193593500 193593500 193593500 500 High 193593500 193593500 193593500 530 High 193593500 193593500 193593500

    Unit Size Eff. 380V Ckt 2 460V Ckt 2 575V Ckt 2 400 Std 193593500 193593500 193593500 425 Std 193593500 193593500 193593500 450 Std 193524163 193593500 193593500 470 Std 193524163 193593500 193593500 500 Std 193524163 193593500 193593500 525 Std 193524163 193593500 193593500 550 Std 193524163 193593500 193593500

    450 High 193593500 193593500 193593500 475 High 193593500 193593500 193593500 500 High 193524163 193593500 193593500 530 High 193524163 193593500 193593500

    Unit Size Eff. 380V Ckt 3 460V Ckt 3 575V Ckt 3 400 Std 193593500 193593500 193593500 425 Std 193524163 193593500 193593500 450 Std 193593500 193593500 193593500 470 Std 193524163 193593500 193593500 500 Std 193524163 193593500 193593500 525 Std 193524163 193593500 193593500 550 Std 193524163 193593500 193593500

    450 High 193593500 193593500 193593500 475 High 193524163 193593500 193593500 500 High 193593500 193593500 193593500 530 High 193524163 193593500 193593500

    KM3-1 (Circuit 1) 1 per circuit

    KM3-2 (Circuit 2) 1 per circuit

    KM3-3 (Circuit 3) 1 per circuit

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 50

    F5-1 (Ckt 1); F5-2 (Ckt 2); F5-3 (Ckt 3)Compressor Contactor Overloads

    ControlsUnits with Wye-Delta Starter Panel (Code 09= WD)

    Power Side Components

    Unit Size Eff. 380V Ckt 1 460V Ckt 1 575V Ckt 1 400 Std 193513501* 193513501 193513501 425 Std 193513501* 193513501 193513501 450 Std 193515001 193513501* 193513501 470 Std 193515001 193513501* 193513501 500 Std 193515001 193513501* 193513501 525 Std 193515001** 193515001 193513501* 550 Std 193515001** 193515001 193513501*

    450 High 193513501* 193513501 193513501 475 High 193513501* 193513501 193513501 500 High 193515001 193513501* 193513501 530 High 193515001 193513501* 193513501

    Unit Size Eff. 380V Ckt 2 460V Ckt 2 575V Ckt 2 400 Std 193513501* 193513501 193513501 425 Std 193513501* 193513501 193513501 450 Std 193515001 193513501* 193513501 470 Std 193515001 193513501* 193513501 500 Std 193515001 193513501* 193513501 525 Std 193515001** 193515001 193513501* 550 Std 193515001** 193515001 193513501*

    450 High 193513501* 193513501 193513501 475 High 193513501* 193513501 193513501 500 High 193515001 193513501* 193513501 530 High 193515001 193513501* 193513501

    Unit Size Eff. 380V Ckt 3 460V Ckt 3 575V Ckt 3 400 Std 193513501* 193513501 193513501 425 Std 193515001 193513501* 193513501 450 Std 193513501* 193513501 193513501 470 Std 193515001 193513501* 193513501 500 Std 193515001** 193515001 193513501* 525 Std 193515001 193513501* 193513501 550 Std 193515001** 193515001 193513501*

    450 High 193513501* 193513501 193513501 475 High 193515001 193513501* 193513501 500 High 193513501* 193513501 193513501 530 High 193515001 193513501* 193513501

    F5-1 (Circuit 1)

    F5-2 (Circuit 2)

    F5-3 (Circuit 3)

    * May also use Overload p/n 193515001 in this application.** May also use Overload p/n 193524176 in this application.

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 51

    KM1-1 (Ckt 1); KM1-2 (Ckt 2); KM1-3 (Ckt 3) Compressor Contactors

    ControlsUnits with Solid State Starter Panel (Code 09= SS)

    Power Side Components

    Unit Size Eff. 380V Ckt 1 460V Ckt 1 575V Ckt 1 400 Std 193593804 193593803 193593802 425 Std -- 193593803 193593802 450 Std -- 193593900 193593803 470 Std -- 193593900 193593803 500 Std -- 193593900 193593803 525 Std -- 193593900 193593804 550 Std -- 193593900 193593804

    450 High 193593900 193593803 193593802 475 High -- 193593803 193593802 500 High -- 193593804 193593804 530 High -- 193593804 193593804

    Unit Size Eff. 380V Ckt 2 460V Ckt 2 575V Ckt 2 400 Std 193593804 193593803 193593802 425 Std -- 193593803 193593802 450 Std -- 193593900 193593803 470 Std -- 193593900 193593803 500 Std -- 193593900 193593803 525 Std -- 193593900 193593804 550 Std -- 193593900 193593804

    450 High 193593900 193593803 193593802 475 High -- 193593803 193593802 500 High -- 193593804 193593804 530 High -- 193593804 193593804

    Unit Size Eff. 380V Ckt 3 460V Ckt 3 575V Ckt 3 400 Std 193593804 193593803 193593802 425 Std -- 193593900 193593803 450 Std -- 193593803 193593802 470 Std -- 193593900 193593803 500 Std -- 193593900 193593804 525 Std -- 193593900 193593803 550 Std -- 193593900 193593804

    450 High 193593900 193593803 193593802 475 High -- 193593804 193593804 500 High -- 193593803 193593802 530 High -- 193593804 193593804

    Quantity = 3 per unit

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 52

    ControlsUnits with VFD Starters (Code 9 = VE or VF)

    Control Side Detail

    F10 F11 F12, F59

    KLJ-1, KLJ-2, KLJ-3

    K11, K13, K23, K33MPR1, MPR2, MPR3

    For any control components not detailed or for unit specific controls, please contact Daikin McQuay Parts with the Control Box Serial Number and Control Box Part/GOI Number.

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 53

    ControlsUnits with VFD Starters (Code 9 = VE or VF)

    Control Side Detail

    KM101thru

    KM110

    KM201thru

    KM210

    KM301thru

    KM310

    For any control components not detailed or for unit specific controls, please contact Daikin McQuay Parts with the Control Box Serial Number and Control Box Part/GOI Number.

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 54

    Sch. Part Part Sym. Description Number Qty. AC Expansion Controller- Alarms 193407501 1 AWM Advanced Web Module (D-NET) 2, 3 193408502 1 CC1,2,3 Controller- Circuit 193407501 3 EEXV1,2,3 Extension I/O for Electr. Exp. Valve (Code 29= ND, SD) 193407801 3 EEXV1,2,3 Extension I/O for Electr. Exp. Valve (Code 29= LD, SL) 193407901 3 F11 Fuse- Unit Controller, 10A Rejection Type 349937131 1 F12 Fuse- Outlet 349937131 1 F59 Fuse- Evaporator Heater Protection 349937116 1 F90 Thermostat, Exhaust Fan 3 193418404 1 FC, FC2,3 Expansion Controller- Fans 193407601 3 GFR1,2,3 Relay- Ground Fault 193466201 * K11 Relay- Emergency Stop 349934923 1 K13 Relay- Mechanical High Pressure, Circuit 1 349934724 1 K23 Relay- Mechanical High Pressure, Circuit 2 349934724 1 K33 Relay- Mechanical High Pressure, Circuit 3 349934724 1 KLJ-1,2,3 Relay- Liquid Injection 193439901 3 MPR1,2,3 Relay- Motor Protector 349934722 3 Q0 Switch- Unit Shut Off 001355000 1 Q1,2,3 Switch- Pumpdown 001355000 1 Q11 Switch- Emergency Stop (Not shown- mounted through the door) 193441101 1 REC1 Receptacle- Ground Fault Interrupter 039003600 1 RR Rapid Restore (Not shown, located next to AC Controller) 193407701 1 T2 Transformer- 100VA, 115V-24V 330386105 1 T20-1,2,3 Transformer- 50VA, 115V-24V 349937203 3 UC Controller- MicroTech III 193407301 1 UC Battery for UC Controller 193409001 1 VFD1,2,3 Fan VFD 193466002 3

    ControlsUnits with VFD Starters (Code 9 = VE or VF)

    Control Side Components

    1 To determine the correct Ammeter part number, refer to the Device ID label found inside the unit control panel or contact Daikin

    McQuay Parts with the Control Box GOI number and/or the unit GO number and unit serial number.2 This control board must be programmed in order to function correctly. When ordering a replacement, provide the unit model and serial

    number so that unit specific software can be loaded before shipment.3 Not shown

    * Qty = 1 on Std Short Circuit units (Code 12 = PC,DC,WN); Qty = 3 High Short Circuit units (Code 12 = DH, WH)

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 55

    Sch. Sym. Part Description Part Number Qty

    F10 Exhaust Fan Fuse, 10A 349937131 1

    NS F130 Fuse- PVM 349937120 1

    KM101- 310 Contactor- Fan (Std SCCR, Code 12= PC, DC, WN) 349932123 varies

    KM101-310 Contactor- Fans (High SCCR, Code 12= DH, WH) 349932121 varies

    KM101-310 Link Module for Fan Contactor 349932922 varies

    LR1, 2, 3 Line Reactor 349964902 3

    Q101-110 MSP- Fans Circuit #1 349934055 1/fan Q201- 210 MSP- Fans Circuit #2 349934055 1/fan Q301- 310 MSP- Fans Circuit #3 349934055 1/fanNS = Not Shown

    ControlsUnits with VFD Starters (Code 9 = VE or VF)

    Control Side Components

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 56

    ControlsUnits with VFD Starters (Code 9 = VE or VF)

    Control Side Components

    Unit Efficiency F100 & F200 F100 & F200 F300 F300 Size (Code 4) 380V 460V 380V 460V Circuit 1 &2 Circuit 1 & 2 Circuit 3 Circuit 3

    F100, 200, 300 450 High 349939626 349939625 349939626 349939625 475 High 349939626 349939625 349939628 349939626 500 High 349939628 349939626 349939626 349939625 530 High 349939628 349939626 349939628 349939626

    F100, F200, F300: Fan Circuit Breakers

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 57

    ControlsUnits with VFD Starters (Code 9 = VE or VF)

    Power Side Detail

    Single Point Power Connection

    F1 F2 F3

    PD1 PD2 PD3

    T21-1T21-2T21-3

    MP1MP2MP3

    For any control components not detailed or for unit specific controls, please contact Daikin McQuay Parts with the Control Box Serial Number and Control Box Part/GOI Number.

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 58

    ControlsUnits with VFD Starters (Code 9 = VE or VF)

    Power Side Detail

    Multi-Point Power Connection

    F1 F2 F3

    T21-1T21-2T21-3

    MP1MP2MP3

    For any control components not detailed or for unit specific controls, please contact Daikin McQuay Parts with the Control Box Serial Number and Control Box Part/GOI Number.

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 59

    ControlsUnits with VFD Starters (Code 9 = VE or VF)

    Power Side Detail

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 60

    Sch. Part Part Sym. Description Number Qty. AM1 Ammeter- 0-600A 193524137 1 AM1 Ammeter- 0-1200A 193524138 1

    CT 4,5,6 Current Transformer 2 600:5A 193432206 3 CT 4,5,6 Current Transformer 2 1200:5A 193432207 3 CT 4,5,6 Current Transformer 2 1500:5A 193432208 3

    F120,220 Fuse- Control Transformer, 15A Rejection Type (380V) 349937133 3 F120,220 Fuse- Control Transformer, 12A Rejection Type (460V) 349937132 3

    F0-1,2,3 Crankcase Heater MSP (Std SCCR, Code 12= PC, DC or WN) 349934026 3 F0-1,2,3 Crankcase Heater MSP (Hi SCCR, Code 12= DH or WH) 349934006 3

    K1,2,3 Relay- Crankcase Heater (Code 12= PC, DC or WN) 193454201 3

    MP1,2,3 Motor Thermal Protection 330343901 3

    Q12 Fuse- Control Transformer, 20A Non-rejection Type 349937036 1

    SS1 Switch- Voltmeter 193446601 1 SS2 Switch- Ammeter 193446101 1

    T1 Transformer- Control, 2000VA, 380V-115V 349992908 1 T1 Transformer- Control, 2000VA, 460V-115V 038253958 1 T1 Transformers include the following: Finger Safe Cover for T1 349955901 1 Fuse Puller Kit for T1 49955801 1

    T21-1,2,3 Transformer- 50VA, 115V-24V 349937203 3

    VM1 Voltmeter- 0-600V 193524139 1

    ControlsUnits with VFD Starters (Code 9 = VE or VF)

    Power Side Components

    Sch. Part Part Sym. Description Number Qty Units with Single Point Pwr Blk or Disconnect (Code 12 = PC, DC or DH) CT-GFR1 or GCT1 Ground Fault Current Sensor 193461101 1

    Units with Multi Point Disconnect (Code 12 = WN or WH) GCT1,2,3 or GCT1,2,3 Ground Fault Current Sensor 193461101 3Note: Current Sensors not shown on diagram.

    2 To determine the correct Current Transformer part number, refer to the Device ID label found inside the unit control panel or contact

    Daikin McQuay Parts with the Control Box GOI number and/or the unit GO number and unit serial number.

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 61

    Unit Voltage Circuit 1 Circuit 2 Circuit 3 Size VFD-1 VFD-2 VFD-3

    450 460V 193439003 193439003 193439003 450 380V 193439004 193439004 193439004

    475 460V 193439003 193439003 193439004

    500 460V 193439004 193439004 193439003

    530 460V 193439004 193439004 193439004

    Used with 193439003 Compressor VFD (362A) EMI1,2,3 EMI Filter (Code 9 = VE) 193445702

    Used with 193439004 Compressor VFD (414A) EMI1,2,3 EMI Filter (Code 9 = VE) 193445702

    VFD-1, VFD-2, VFD-3 Compressor VFD Starter

    ControlsUnits with VFD Starters (Code 9 = VE or VF)

    Power Side Components

    EMI1,2,3 EMI Filter

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 62

    ControlsUnits with VFD Starters (Code 9 = VE or VF)

    Power Side Components

    Sch. Sym. Part Description F1, 2, 3 Circuit Breaker- Compressor 1, 2, 3 Only on Single Point units: C12= PC, DC, DH JFU1, 2, 3 Fuse- Compressor Circuit Units with HSCCR: C12= DH, WH PD1, 2, 3 Power Block- Main Units with Power Block: C12= PC Q10 Switch- Main Disconnect Units with Disc Switch: C12= DC, DH, WN, WH Q20 Switch- Main Disconnect Only on Multi-Point units: C12= WN, WH Q30 Switch- Main Disconnect Only on Multi-Point units: C12= WN, WH

    To insure proper replacement part number for any of the items above, refer to the Device ID label found inside the con-trol panel or contact Daikin McQuay Parts with the Control Box GOI number and/or the unit GO number and unit serial number.

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 63

    Sch. Sym. Part Description Part Number Qty

    M10 Control Box Exhaust Fan Unit sizes 450-500 193441002 1 M10 Control Box Exhaust Fan Unit sizes 530 193441003 1

    M11 Control Box Intake Fan Unit sizes 450-530 193440803 1

    M12 Control Box Exhaust Fan Unit sizes 450-500 193441002 1 M12 Control Box Exhaust Fan Unit size 530 193441003 1

    ControlsUnits with VFD Starters (Code 9 = VE or VF)

    Control Box Exhaust and Intake Fans

    M12M10

    M11

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 64

    ControlsTerminal Box

    Ref. Part Part No. Description Number Qty. 50 Motor Terminal Plate 131073022 1 per compressor Motor Terminal Plate Gasket 300040078 1 per compressor P3 Terminal Plate Insulator 131083020 6 per compressor Motor Terminal Bolt, M10 (Starter side) 130306091 6 per compressor Lock Washer (Starter side) 130902028 6 per compressor P4 Mounting Bolt, M8 (Plate mounting) 300040079 14 per compressor P5 Terminal Box Screw, M6 330821902 4 per compressor

    Type B Terminal Plate

    For more information, see Parts Bulletin PB-0512-01.

    P3

    P5

    P450

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 65

    AccessoriesPackaged Unit (Code 4= SE, HE, PE)

    Units with Wye-Delta or Solid State Starter (Code 9 = WD or SS) Isolator Kits, Neoprene-In-Shear

    Complete NIS Isolator Part #s and Quantities Unit Kit 331481404 331481403 331481401 331481402 331481405 Part # Charcoal Lime Brown Brick Red Purple Units with Aluminum Fin Condensers 400**S 332325843 4 4 425**S 332325843 4 4 450**S 332325834 4 2 2 2 450**H 332325834 4 2 2 2 470**S 332325834 4 2 2 2 475**H 332325844 4 2 2 2 500**S 332325844 4 2 2 2 500**H 332325844 4 2 2 2 525**S 332325844 4 2 2 2 530**H 332325845 2 2 2 4 550**S 332325845 2 2 2 4 Units with Copper Fin Condensers 400**S 332325833 4 2 2 425**S 332325833 4 2 2 450**S 332325835 2 2 4 2 450**H 332325846 2 4 2 2 470**S 332325846 2 4 2 2 475**H 332325845 2 2 2 4 500**S 332325845 2 2 2 4 500**H 332325845 2 2 2 4 525**S 332325845 2 2 2 4 530**H 332325845 2 2 2 4 550**S 332325845 2 2 2 4S= Standard Efficiency: Code 4 = S*H= High Efficiency: Code 4 = H*P= Premium Efficiency: Code 4 = P*

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 66

    Complete Unit Kit 332620800 332620500 332620400 332620600 332620900 332621000 Part # Dark Green Black Red Dark Purple Gray White Units with Aluminum Fin Condenser Coils 400**S 332320848 16 16 425**S 332320848 16 16 450**S 332320850 16 8 16 450**H 332320850 16 8 16 470**S 332320850 16 8 16 475**H 332320850 16 8 16 500**S 332320850 16 8 16 500**H 332320835 8 8 8 16 525**S 332320835 8 8 8 16 530**H 332320835 8 8 8 16 550**S 332320835 8 8 8 16 Units with Copper Fin Condenser Coils 400**S 332320832 8 16 8 425**S 332320832 8 16 8 450**S 332320836 16 8 16 450**H 332320837 16 8 16 470**S 332320837 16 8 16 475**H 332320853 16 8 16 500**S 332320853 16 8 16 500**H 332320853 16 8 16 525**S 332320853 16 8 16 530**H 332320853 16 8 16 550**S 332320853 16 8 16

    AccessoriesPackaged Unit (Code 4= SE, HE, PE)

    Units with Wye-Delta or Solid State Starter (Code 9 = WD or SS) Isolator Kits - Spring

    Spring Isolator Part #s and Quantities

    S= Standard Efficiency: Code 4 = S*H= High Efficiency: Code 4 = H*P= Premium Efficiency: Code 4 = P*

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 67

    AccessoriesPackaged Units (Code 4= SE, HE, PE)

    Units with VFD Starter (Code 9 = VF or VE) Isolator Kits - Neoprene-In-Shear

    Complete NIS Isolator Part #s and Quantities Unit Kit 331481403 331481404 Part # Lime Charcoal Units with Aluminum Fin Condensers 450**H 332325824 12 475**H 332325824 12 500**H 332325824 12 530**H 332325825 8 4 Units with Copper Fin Condensers 450**H 332325824 12 475**H 332325824 12 500**H 332325827 6 6 530**H 332325827 6 6S= Standard Efficiency: Code 4 = S*H= High Efficiency: Code 4 = H*P= Premium Efficiency: Code 4 = P*

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 68

    Complete Spring Isolator Part #s and Quantities Unit Kit 332620800 332620600 332620900 Part # Dark Green Dark Purple Gray Units with Aluminum Fin Condensers 450**H 332320825 40 8 475**H 332320826 48 500**H 332320826 48 530**H 332320827 24 24 Units with Copper Fin Condensers 450**H 332320825 40 8 475**H 332320826 48 500**H 332320827 24 24 530**H 332320827 24 24

    AccessoriesPackaged Units (Code 4= SE, HE, PE)

    Units with VFD Starter (Code 9 = VF or VE) Isolator Kits - Spring

    S= Standard Efficiency: Code 4 = S*H= High Efficiency: Code 4 = H*P= Premium Efficiency: Code 4 = P*

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 69

    AccessoriesRemote Evap Units (Code 4= SM, HM, PM)

    Units with Wye-Delta or Solid State Starter (Code 9= WD, SS)Isolator Kits - Neoprene-In-Shear

    Complete NIS Isolator Part #s and Quantities Unit Kit 331481404 331481403 331481401 331481402 331481405 Part # Charcoal Lime Brown Brick Red Purple Aluminum Fin Condenser Coil 400**S 332325830 4 2 2 425**S 332325830 4 2 2 450**S 332325842 4 2 2 2 450**H 332325842 4 2 2 2 470**S 332325842 4 2 2 2 475**H 332325848 4 2 4 500**S 332325842 4 2 2 2 500**H 332325849 4 4 2 525**S 332325849 4 4 2 530**H 332325849 4 4 2 550**S 332325849 4 4 2 Copper Fin Condenser Coil 400**S 332325843 4 4 425**S 332325843 4 4 450**S 332325846 2 4 2 2 450**H 332325850 4 4 2 470**S 332325846 2 4 2 2 475**H 332325846 2 4 2 2 500**S 332325846 2 4 2 2 500**H 332325844 4 2 2 2 525**S 332325844 4 2 2 2 530**H 332325845 2 2 2 4 550**S 332325845 2 2 2 4

    S= Standard Efficiency: Code 4 = S*H= High Efficiency: Code 4 = H*P= Premium Efficiency: Code 4 = P*

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C, Unit Rev. 00 RPL Rev. NEW 06/13 RPL 700028300 / Page 70

    Complete Unit Kit 332620800 332620500 332620400 332620600 332620900 332621000 Part # Dark Green Black Red Dark Purple Gray White Units with Aluminum Fin Condenser Coils 400**S 332320848 16 16 425**S 332320848 16 16 450**S 332320834 8 8 8 16 450**H 332320833 8 8 8 16 470**S 332320834 8 8 8 16 475**H 332320850 16 8 16 500**S 332320850 16 8 16 500**H 332320850 16 8 16 525**S 332320850 16 8 16 530**H 332320850 16 8 16 550**S 332320850 16 8 16 Units with Copper Fin Condenser Coils 400**S 332320848 16 16 425**S 332320848 16 16 450**S 332320856 16 8 8 8 450**H 332320856 16 8 8 8 470**S 332320856 16 8 8 8 475**H 332320858 24 16 500**S 332320859 16 8 16 500**H 332320860 16 16 8 525**S 332320860 16 16 8 530**H 332320853 16 8 16 550**S 332320853 16 8 16

    AccessoriesRemote Evap Units (Code 4= SM, HM, PM)

    Units with Wye-Delta or Solid State Starter (Code 9= WD, SS)Isolator Kits - Spring

    Spring Isolator Part #s and Quantities

    S= Standard Efficiency: Code 4 = S*H= High Efficiency: Code 4 = H*P= Premium Efficiency: Code 4 = P*

  • Air Cooled Screw Chiller, AWS 400-550, 3-Ckt, Vint. C,