Upload
voanh
View
214
Download
0
Embed Size (px)
Citation preview
CLED-1
SWITCH-PUMP108357-21-000ACTUATOR108356-23-CHT
TO TANKHEATER PAD
WIRE ASM-MAIN HOLDING151317-03-000
WIRE ASM-AUX HOLDING151316-03-000
3
3
3
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
CODES/STANDARDS USA
CODES/STANDARDS-CSA/CMVSS
DRAINAGE SYSTEM-HEATED
DRAINAGE SYSTEM/HEAT-PREWIRE
2651B1
1B1
265
23T
23R
23R OR 23T
PANEL-RCP151376-02-CHTADAPTER082134-01-000NUT82136-01-000LABEL157486-01-CHTSCREWG67-10-12U (4)
NOTES:
ROUTE TANK SENSOR WIRES SO THEY DO NOT PASS OVERSENSORS. USE WIRE TIE MOUNT 155366-01-000 AS NEEDED.TANK SURFACE MUST BE CLEANED USING ISOPROPYL ALCOHOLAND PRIME WITH PRIMER 94.
WIRE ROUTED THROUGH FLOOR IN THIS AREA.
2.
3
AB
AA
VIEW AA
6 PIN HSGWITH GRN TAPE
PORT-SOLAR,SINGLE000163158 / 328863-01-000SCREWG39-10-12U (4)
CLAMP10495-02-000 (5)SCREWG11-06-12U (5)
2 PIN HSG FROMWIRE ASM-CHASSISCIRCUIT; AEZ
CLAMP10495-02-000 (8)SCREWG11-06-12U (8)
VIEW AB
TO WIRE ASM-SIDEWALL
VIEW AC
TO SLIDEOUT
3 TO SLIDEOUT
100
100
490
3
CONTROL-SLIDEOUT,IN-WALL189400-01-000SCREWG39-08-12U (4)DETAIL AC
2 PIN HSG FROMWIRE ASM-CHASSISCIRCUITS; LLL,LLK
6 PIN HSGWITH YEL TAPE
4 PIN HSG FROMWIRE ASM-CHASSISCIRCUITS;ABY,ABZ,DR,DU
1. AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PERCODE REQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRETIE 8343 OR 108046 AND SCREW G67-XX-XXX OR G56-XX-XXXAS APPROPRIATE FOR INSTALLATION.
SPLICE YELLOW TO RED AND WHITE TO BLACK.4
PLATE-COAX149557-03-CHTSCREWG39-08-08U (2)
4
3
UNSPECIFIED TOLERANCES: MATERIAL:
C
D
1
TWO-PLACE (X.XX)
DSNR:
DESCRIPTION:
8
2
B
ALL DIMENSIONS ARE IN MILLIMETERSDFTR:
6
A
6
FIRST USED:
A
REV
WHOLE DIM (X)
D
REF:
8
ITEM/PART NO:
4
WEIGHT: (LBS)
SHEET:
7
B
2
4
REFER TO ES0018 FOR FASTENERTIGHTENING GUIDELINES
ANGLE
5
5
13
COPYRIGHT 2016 WINNEBAGO INDUSTRIES, INC.
ONE-PLACE (X.X)
C
7
WIRING INSTL-BODY,12V
1 OF 7 000115332 / 32195301000
3
1.5
0.50
1
18 524J
COVER-ELECTRICAL194965-01-CHTLABEL-SLIDEOUT098379-09-000
AD
VIEW AD
PANEL-SWITCH000215380 / 303681-01-CHTSWITCH-ROCKER108357-06-000 (2)ACTUATOR-SWITCH108356-01-CHT (2)LABEL-STABILIZER000007799 / 310651-01-CHT
CABLE-DATA, CSW INVERTER,RJ1TO INVERTER
JACKS-STABILIZING, ELECTRIC64A
64A
PANEL-SERVICE132862-16-CHT
3
WATERPUMP
07-May-2018
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
SPEAKER-ROUND160868-01-CHT (2)SPEAKER-GRILLE,ROUND160868-02-CHT (2)SCREWG11-08-08U (8)
SWITCHDETAIL DD
WIRE ASM-OVHD000035595 / 318034-01-000
SPEAKER-SUB124884-01-000GRILLE151844-01-CHTSCREWG11-08-12U
SWITCHDETAIL DA
WIRE ASM-COACHTO OVHD LIGHTS
WIRE ASM-COACHTO RIGHT SIDE
WIRE ASM-HEATER,RELAY153891-01-000WIRE ASM-HEATER,TANKS134551-15-000RELAY63912-02-000SCREWG11-08-12U
8 PIN HSGTO WATER PUMPSWITCH
23T DRAINAGE SYSTEM-HEATED
SWITCHDETAIL DB
LPGD
23T
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
4
4
1B1
CODES/STANDARDS-CSA/CMVSS265
CODES/STANDARDS USA1B1
265
TO COMPARTMENT LAMP
SWITCHDETAIL DC
4
DRAINAGE SYSTEM/HEAT-PREWIRE23R
23R OR
GA
TO WIRE ASM-SIDEWALL
WIRE ASM-CHASSIS
LIGHT-TAPE,LED187693-41-CHT
BA
36
VIEW BA
WIRE ROUTED THROUGH FLOOR IN THIS AREA.4
CLEAN SURFACE WITH CLEAN TOWEL.2
2
3 CENTER LIGHT STRIP IN OPENING.
3
NOTES:
AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PERCODE REQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRETIE 8343 OR 108046 AND SCREW G67-XX-XXX OR G56-XX-XXXAS APPROPRIATE FOR INSTALLATION.
1.
THERMOSTAT000016556 / 313194-01-CHT000016270 / 313193-01-CHTSCREWG11-06-08U (2)
25Q
6
29Z
8
SECURE ABOVE FLOOR WITH SCREW CALLED OUT.
DC IN
SPLITTER-HDMI,1X2192138-01(REF)
HDMI IN
HDMI OUT2 HDMI OUT1
PLATE-WALL,HDMI(REF)
8
DETAIL BB
5 CONNECTED TO THE REAR SIDE OF THE PLATE.
5
7
TO LEFT BDRMHDMI WALL PLATE
OR HDMI 1ON BDRM TV
CABLE-HDMIWITH SATELLITERECEIVER LABEL
CABLE-HDMI(REF)
HDMI 1ON MAIN TV
CABLE-HDMI(REF)
7
29Z A/C HEAT PUMP
25Q A/CWIRE IS PART OF WIRE ASM-COACH.
7
6
SEE WIRING INSTL-TV/DVD FOR ADDITIONAL INFORMATION.
9 CONNECT RED WIRE TO YELLOW WIRE AND CONNECT BLACKWIRE TO WHITE WIRE.
9
158
4
7
SHEET:
2
4
C
A
DESCRIPTION:
B
3 2
REV
A
ITEM/PART NO:
3
D
6
78
D
5
B
C
16
WIRING INSTL-BODY,12V
000115332 / 32195301000 2 OF 7
CONTROL-WATER HEATER000027745 / 316105-01-CHTSCREWG67-08-12U (2)
-
1BU WTR HTR TKLS W/RECIRCUL PUMP
1BU
+
USB-CHARGER DUAL,DC188312-01-000DETAIL BC
DETAIL BC
WHT YEL
07-May-2018
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
1B1 265
1B1 CODES/STANDARDS USA
265 CODES/STANDARDS-CSA/CMVSS
DOOR SWITCHDETAIL CF
TO WIRE ASM-CHASSIS
WIRE ASM-COACH000115336 / 32195601000
2-PIN HOUSINGTO WATER PUMPMODULE-WATER PUMP176001-01-000SCREWG11-10-12U (2)DETAIL CD
TO ANTENNA
CA
DETAIL CA
READ-62
WIRE ASM-COACHTO LEFT SIDE
TO FURNACE
WIRE ASM-WATER TANK151317-01-000
CONNECTS TOWATER HEATERDETAIL CG
TO LEFT SIDE
CLED-1
SEE WIRING INSTL-TV/DVD FOR ADDITIONAL INFORMATION
PANEL SUPPLIED WITH GENERATOR.2
WITH FEATURE CABLE SUPPLIED WITH DIESEL GENERATOR.3
GENERATOR CONTROLCABLE ROUTED THROUGHFLOOR IN THIS AREA
33F3
GEN-3.5 KW ONAN DIESEL33F
WTR HTR TKLS W/RECIRCUL PUMP1BU
33F
CB
4
TO WIRE ASM-SIDEWALL
DISTRIBUTION PANELDETAIL DN
CROSSOVER150140-01-000SCREWG11-08-08U (4)
SPEAKER171547-01-CHT (2)SCREWG39-10-12U (8)
SWITCHDETAIL DL
5 MOUNTED ON THE EXTERIOR OF THE SIDEWALL.
WIRES ARE PART OF WIRE ASM-SIDEWALL.
6
WM(WHT)
WL(YEL)
DETAIL CE
ROUTE WIRESTHRU HOLE
WL,WMTO POWER DOORLOCK ACTUATORDETAIL CE7
7 GROMMET8386-01-000
9
SWITCHESDETAIL DR
SWITCHESDETAIL DF
SWITCHDETAIL DG
11
MOUNT MAGNET USING PILOT HOLES IN SCREEN DOOR FRAME.MOUNT WITH MAGNET TOWARD SWITCH.
9 MOUNT SWITCH AND SPACER TO BLOCK ON JAMB.ADJUST HEIGHT TO MATCH MAGNET.
8
LIGHT-TAPE,LED187693-10-CHT
COUNTER TOP
RADIO-WALL MOUNT000130023 / 325461-01-000SCREW76790-03-000 (4)FILTER-GROUND LOOP123324-01-000
SIDEWALL
LCS-1
CONVERTER-45 AMP184353-01-000SCREWG67-10-12U (4)
SWITCHESDETAIL DSRELAY-AWNING63912-02-000
DETAIL CF
8
SWITCH/MAGNET-STEP, ELECTRIC116995-03-000SCREWG11-06-08U (4)
JAMB-DOOR
5
PLATE-WALL179004-02-CHT
TO REFRIGERATOR
11
11
TO WIRE ASM-ROOF
PLATE-WALL,KEYSTONE175530-04-CHTSCREWG13-05-10U (2)DETAIL BB
PLATE-WALL,COAX149557-09-CHTSCREWG67-10-08U (2)
GENERATORCONTROL PANEL(REFERENCE)
33F2
SWITCHDETAIL DM
LABEL-WARNING116549-01-000
SWITCH108357-18-000ACTUATOR108356-31-CHTPLATE-SWITCH144363-02-CHTSCREWG11-08-10U (2)
52G11
SWITCHDETAIL DP
REMOTE PANEL-INVERTER000037772 / 318694-01-CHTSCREW000G11-06-08U (2)
MONITOR PANEL175724-01-000175724-02-000175724-06-000175724-03-000SCREWG11-08-12U (4)
DETAIL CB
SWITCHDETAIL DK
SWITCHESDETAIL DJ
CC
LED-2
SWITCHDETAIL DH
LIGHT-TAPE,LED187693-13-CHT
VIEW CC
SPLITTER-HDMI192138-01-000DETAIL FB
41
42B
CLEAN SURFACE WITH CLEAN TOWEL.10
10
42B
CENTER LIGHT STRIP IN OPENING.
6
GEN-3.6KW ONAN LP MICROQUIET52G
XXZ
FFZ GGA
YYF
DETAIL CD
52G
13
53B
4
31P FRONT CAP W/O BED
31T FRONT CAP W/ BED
CROSSOVER COIL150140-02-000CLAMP10497-02-000SCREWG67-10-12U
CONNECT CABLE-HDMI WITH TV 2 LABEL TO BACK OF PLATE WITH
13 CONNECT CABLE-HDMI WITH SATELLITE RECIEVER LABELTO BACK OF PLATE WITH
CROSSOVER150140-01-000SCREWG11-08-08U (4)WIRE ASM-JUMPER CROSSOVER189827-01-000CONNECTS TO CIRCUITS;HM,HN,GP,GN,MMK,MML.MMN,MMM
1133FSPLITTER-HDMI
192138-01-000DETAIL BB
11
42B
31T
31P
42B
42B TV,REAR-WITHOUT
53B
11
NOTES:
AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PERCODE REQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRETIE 8343 OR 108046 AND SCREW G67-XX-XXX OR G56-XX-XXXAS APPROPRIATE FOR INSTALLATION.
1.
PLATE-WALL,KEYSTONE175530-04-CHT (2)SCREWG13-05-10U (4)CONNECTOR-HDMI179395-01-000 (2)
CLAMP WIRES AWAY FROM FURNACE.12
CONTROL-CHARGE,SOLAR 30 AMP191278-01-000SCREWG11-08-08U (2)DETAIL DE
1BU
53B WTR HTR-6GAL ELECTRIC/LP GAS
33F1BU
158
4
7
SHEET:
2
4
C
A
DESCRIPTION:
B
3 2
REV
A
ITEM/PART NO:
3
D
6
78
D
5
B
C
16
WIRING INSTL-BODY,12V
000115332 / 32195301000 3 OF 7
REMOVE SCREW FROM MAGNET SWITCH TO INSTALLLOCK WASHER AND TERMINALS.
14
14 WASHER-LOCK000007554 / 310611-01-000 (2)
JW-1RED
BLACKJX
DETAIL CG
WIRE ASM-COACH
WATERHEATER
1BU
WIRE ASM-RESISTOR140195-01-000 (3)
PLATE-WALL,SINGLE COAX HORIZ149557-13-CHT
USB-CHARGER DUAL,DC188312-01-000 (2)DETAIL BC
TO PORT-SOLAR, 3 POSITION
IN
OUT
AWNING
116549-01G
WARNINGCRUSH HAZARD. Keep people and objects clear of the insideand the outside of the slideout room when operating. Failureto comply could result in death or serious injury.
Water
ONE PLACE
HeaterElectric
GenSet
HeaterL.P.
Start
Pump
Meter
Stop
BatteryTank
Levels
L.P.
VALVE
HOLDING TANK HEATERTURN OFF When Not In Use
SEE OPERATORS MANUAL
Switch Battery LoadGround
07-May-2018
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
1B1 265
1B1 CODES/STANDARDS USA
265 CODES/STANDARDS-CSA/CMVSS
SWITCH-ROCKER135740-01-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-01-CHTSCREWG11-08-08U (2)
DETAIL DD
JCXU
HOLDING TANK HEATERTURN OFF When Not In Use
SEE OPERATORS MANUAL
JC
SWITCH-BLANK138253-01-CHTSWITCH-ROCKER135740-06-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-01-CHTSCREWG11-08-08U (2)LABEL-SWITCH134563-01-CHT
DETAIL DP
JAHR
SWITCH-ROCKER135740-04-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-01-CHTSCREWG11-08-08U (2)
PE-1
DETAIL DM
23T
23T
NOTES:
PLATE-SWITCH158431-19-CHTSCREWG11-06-10U (4)
SWITCH-BATT DISC108357-18-000ACTUATOR-BATT DISC108356-19-CHTWIRE ASM-THERM186796-01-000
SWITCH-STEP108357-19-000
DETAIL DR
2 WIRE IS MARKED WITH YELLOW TAPE.
DETAIL DN(REAR)
DETAIL DS
SWITCH-ROCKER135740-04-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-01-CHTSCREWG11-08-08U (2)WIRE ASM-RESISTOR140195-01-000
DETAIL DA
JCPD-1
L.P.
VALVE
SWITCH-ROCKER135740-01-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-59-CHTSCREWG11-08-08U (2)
KKDWB
23T DRAINAGE SYSTEM-HEATED
23R DRAINAGE SYSTEM/HEAT-PREWIRE
23ROR
OR 23R
DETAIL DC
316 SKYLIGHT/ROOF VENT, POWER
VENT-POWER VENTILATOR41M
JP
SWITCH-ROCKER108357-14-000ACTUATOR-SWITCH108356-28-CHT
PLATE-SWITCH158431-19-CHTSCREWG11-06-10U (4)
SWITCH-ROCKER108357-06-000ACTUATOR-SWITCH108356-12-CHT
PLUG CONVERTERPOWER CORDINTO CONVIENCERECPTACLE
GROUND BARCIRCUITS;NC,JX,FFE,JM,MS,JY,ND,NF,NE,JP,PM,JN
BLANK
NM
BLANK
3
JB
JD
WB
JA
BLANK
JF
1
JG
JE
M
J
JC
3 CIRCUIT FROM WIRE ASM-COACH.
1 CIRCUIT FROM WIRE ASM-CHASSIS.
SWITCH-WATER PUMP108357-21-000ACTUATOR108356-23-CHTPLATE144363-02-CHTSCREWG11-06-10U (2)
DETAIL DB
SWITCH-ROCKER135740-01-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-01-CHTSCREWG11-08-08U (2)
DETAIL DG
JEPJ
SWITCH-ROCKER135740-01-CHTSWITCH-BLANK138253-01-CHTSWITCH-BASE135741-02-CHTSWITCH-BEZEL135742-02-CHTSCREWG11-06-16U (4)
JCRRC
DETAIL DF
SWITCH-ROCKER135740-01-CHT135740-03-CHTSWITCH-BASE135741-02-CHTSWITCH-BEZEL135742-02-CHTSCREWG11-06-16U (4)
DETAIL DF
JCRRC
GGBJBKJ GGC
JMKJ
31641M
RRBJE
DETAIL DH
SWITCH-ROCKER135740-01-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-01-CHTSCREWG11-08-08U (2)
SWITCH-ROCKER135740-01-CHT (2)135740-04-CHTSWITCH-BASE135741-03-CHTSWITCH-BEZEL135742-03-CHTSCREWG11-08-08U (4)
DETAIL DJ
JCA-1
JCRRA
JBGGZ
SWITCH-ROCKER135740-04-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-01-CHTSCREWG11-08-08U (2)WIRE ASM-RESISTOR140195-01-000
DETAIL DK
JCBBG-1
JE
SWITCH-ROCKER135740-04-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-01-CHTSCREWG11-08-08U (2)
PC-1
DETAIL DL
DRAINAGE SYSTEM-HEATED-W/O1JD
1JD
WIRE IS MARKED WITH GOLD TAPE.4
4
WIRE ASM-COACH
4
8 GRN
8 BLK
2
2
BATTERYCONNECTION
SOLAR PANELCONNECTION
WIRE ASM-COACH
8 GRN & 10 WHT
8 BLK & 10 YEL
DETAIL DE
158
4
7
SHEET:
2
4
C
A
DESCRIPTION:
B
3 2
REV
A
ITEM/PART NO:
3
D
6
78
D
5
B
C
16
WIRING INSTL-BODY,12V
000115332 / 32195301000 4 OF 7
PE
BBG PCPD
A JD14 YEL(TV)
FUSE62901-02-000(5 AMP)
JF14 YEL(AUDIO)
JA12 YEL(PUMP/RG HOOD)
FUSE62901-05-000 (8)(15 AMP)
BLANK
NM12 YEL(TANK HEATERS)
WB16 YEL(LP LEAK DETECTOR)
JC14 YEL(LAMPS)
BLANK
BLANK
JE14 YEL(LAMPS)
JG10 YEL(REFRIGERATOR)
JB14 YEL(FURNACE/VENTS)
DETAIL DN(FRONT)
IN
OUT
AWNING
WATERPUMP
CON-VERTER
A/C
MICRO-WAVE
RECPS 2
RECPS 1
MAIN
15
15
5
15
15
15
15
15
15
AMPS
AMPS
AMPS
8
6
AMPS
AMPS
5
AMPS
30 AMP MAX
30 AMP MAX
DC BRANCH CIRCUIT
10
AMPS
3
AMPS
AMPS
4
AMPS
30 AMP MAX
30 AMP MAX
AMPS
1
7
2
AC BRANCH CIRCUIT
11
12
9
MAIN
AMPS
07-May-2018
VENT-POWER VENTILATOR
1B1 265
CODES/STANDARDS USA
41M
1B1
316
265 CODES/STANDARDS-CSA/CMVSS
SKYLIGHT/ROOF VENT, POWER
31P
31T
READ-6
TO WIRE ASM-ROOF
SPEAKER180783-01-CHT (2)SCREWG11-10-12U (8)
TO ROOF VENTDETAIL EA
PRLED-22
31T
FRONT CAP W/O BED31P
SPEAKER-ROUND160868-01-CHT (2)SPEAKER-GRILLE,ROUND160868-02-CHT (2)SCREWG11-08-08U (8)
FRONT CAP W/BED
WIRE ASM-VENT,ROOF CAP000115179 / 32194501000
WIRE ASM-VENT,ROOF CAP000115185 / 32194601000
41M
JM
BUTT SPLICES (2)(REFERENCE)
DETAIL EA
RED
BUTT SPLICES (2)(REFERENCE)
3-PINHOUSINGS
BRN
WIRE ASM-ROOF CAP
JM
WIRE ASM-ROOF CAP
BLK
WHT
SKYLIGHTWIRING
VENT
JB
JB
DETAIL EA 316
TO ROOF VENTDETAIL EA
TO WIRE ASM-ROOF
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
TO LIGHT-TAPE,LED
158
4
7
SHEET:
2
4
C
A
DESCRIPTION:
B
3 2
REV
A
ITEM/PART NO:
3
D
6
78
D
5
B
C
16
WIRING INSTL-BODY,12V
000115332 / 32195301000 5 OF 707-May-2018
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
1B1 265
1B1 CODES/STANDARDS USA
265 CODES/STANDARDS-CSA/CMVSS
SEE ANTENNA INSTALLATION MANUAL FORCORRECT INSTALLATION PROCEDURE.
2
2
NOTES:
SEE ROOF ASM FOR ADDITIONAL INFORMATION.1.
3 WRAP BRACKET LEGS AROUND ANTENNA BASE.
ANT-RFA
VIEW FANFFROM WIRE ASM-COACH
BRACKET ANTENNAGROUND 3
DETAIL FB 4
5
4 SEE WIRING INSTL-TV/DVD FOR ADDITIONAL INFORMATION.
CONNECT RED WIRE TO YELLOW WIRE ANDCONNECT BLACK WIRE TO WHITE WIRE.
5
FD
FC
DETAIL FC
DETAIL FD
1024
1117
WIRE ASM-COACH
8 BLK TO EMPTYPOST ON
30A BREAKER 8 GRN TOGROUND STUD(STACK GROUNDWIRES)
PORT-SOLAR, 3 POSITION(REF)
6
PORT-SOLAR,3 POSITION191277-01-CHTDETAIL FD
BATHROOM VENT(REF)
BATHROOM VENT(REF)
DC IN
SPLITTER-HDMI,1X2192138-01(REF)
HDMI IN
HDMI OUT2 HDMI OUT1
TO RIGHTBDRM HDMI
WALL PLATEOR HDMI 2
ON BDRM TV
FROMRADIO/DVD
PLAYER
TO HDMI 2ON MAIN TV
HDMI CABLEWITH DVDPLAYER LABEL
HDMI CABLEWITH TV 1 LABEL
HDMI CABLEWITH TV 2 LABEL
6 COIL AND SECURE SOLAR PANEL WIRES ON EACHSIDE OF SOLAR PORT WITH CLAMPS CALLED OUT.
158
4
7
SHEET:
2
4
C
A
DESCRIPTION:
B
3 2
REV
A
ITEM/PART NO:
3
D
6
78
D
5
B
C
16
WIRING INSTL-BODY,12V
000115332 / 32195301000 6 OF 7
LIGHT-TAPE,LED,DIFFUSED190025-36-CHT PANEL-SOLAR 100 WATT, FLEXIBLE
000131101 / 325665-01-000 (2)WASHER077071-01-000 (8)SCREW000G39-10-16U (8)
LIGHT-TAPE,LED,DIFFUSED190025-46-CHT
280
LIGHT-TAPE,LED,DIFFUSED190025-40-CHT
1251
LIGHT-TAPE,LED,DIFFUSED190025-82-CHT
991
LIGHT-TAPE,LED,DIFFUSED190025-09-CHT
991
ANTENNA-TV ROOF000039180 / 318992-01-CHTSCREWG67-10-12U (6)
CLAMP010495-01-000 (2)
07-May-2018
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
CODES/STANDARDS USA
CODES/STANDARDS-CSA/CMVSS
2651B1
1B1
265
6 PIN HSG TOSLIDEOUT MOTORWITH YELLOW TAPE
WIRE ROUTEDBEHIND TRIM PIECEIN THIS AREA
VIEW GA
WIRES CONNECT TOSLIDEOUT CONTROLDETAIL AC
WIRE ROUTEDBEHIND TRIM PIECEIN THIS AREA
6 PIN HSG TOSLIDEOUT MOTORWITH GREEN TAPE
1
NOTES:
WIRE ROUTED THROUGH FLOOR IN THIS AREA.1
1
158
4
7
SHEET:
2
4
C
A
DESCRIPTION:
B
3 2
REV
A
ITEM/PART NO:
3
D
6
78
D
5
B
C
16
WIRING INSTL-BODY,12V
000115332 / 32195301000 7 OF 7
WIRE ASM-SLIDEOUT MOTORS000029924 / 316573-01-000