Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
6
A
1
CHKR
DO NOT SCALE DRAWING
4
ONE-PLACE (X.X)
SHEET
7
REV
DWGNO
DFTR
1
MATERIAL:
DSNR
REV
TWO-PLACE (X.XX)
5
ZONE
A
ANGLE
6 5
8
REFER TO ES0018 FOR FASTENERTIGHTENING GUIDELINES
WHOLE DIM (X)
4
REVISION RECORD
FIRST USEDM.E.
C
B
TITLE:
OF
C
DATE
3
DFTR-ORIG
2
THIRD ANGLE
D
REV
D
P.E.
ORIG. DATE
B
DATE
UNSPECIFIED TOLERANCES ARE:
COPYRIGHT 2014WINNEBAGO
INDUSTRIES, INC.
2 REF:
ALL DIMENSIONS ARE IN MILLIMETERS
8
PROJECTION
7
3
PART NO
A
14 R42QD
1.5
0.50
1
1 4
3
184469
DRAINAGE SYSTEM INSTL
RELEASE
184469
CB
A 9PA
TAILGATE PACKAGE
21S
1B1 CODES/STANDARDS USA
265 CODES/STDS-CSA,CMVSS
21M WASHER/DRYER PREP
214 DISHWASHER DRAWER STYLE
215 DISHWASHER WITHOUT
TAILGATE PACKAGE WITHOUT
9PC
WASHER/DRYER STACKED
G
CALLOUTSSEE DWG NO
116229-01-000
FORDRAINAGE
NOTES:
X-X
9. SEE DRAWING 061607 FOR INSTALLATION OF GROMMETS.
8. SECURE DRAINAGE PIPES TO CABINET USING WIRE TIE 108046-02-000, AND SCREW 000G67-10-12B AT INTERVALS OF NOT OF NOT MORE THAN 4 FEET APART.
7 SECURE VENT PIPE TO GROMMET WITH CLAMP 062401-02-000.
6 VENT PIPE MUST PROJECT 51 MIN AND 64 MAX ABOVE ROOF FOR PROPER FIT AND FUNCTION. ADD S-1 (116666-01-CHT SEAL-VENT PIPE) AROUND PIPE ON ROOF BEFORE VENT CAP IS INSTALLED.
5. SEAL AROUND SHOWER WITH SILICONE.
4 USE SMOOTH PLUMBERS PUTTY 167459-01-000 TO SEAL STRAINER (0.2 PER STRAINER).
3. ALL PIPE AND FITTINGS TO BE ASSEMBLED WITH SOLVENT 004020-01-000 (USA), 004020-02-000 (CAN)
2. SLOPE OF TRAP ARM MUST BE 6 PER 305 mm.
1. SLOPE OF HORIZONTAL PIPING TO BE MINIMUM OF 3 PER 305 mm.CALLOUTS
SEE DWG NO116229-01-000
FORDRAINAGE
NOTES:
X-X
9. SEE DRAWING 061607 FOR INSTALLATION OF GROMMETS.
8. SECURE DRAINAGE PIPES TO CABINET USING WIRE TIE 108046-02-000, AND SCREW 000G67-10-12B AT INTERVALS OF NOT OF NOT MORE THAN 4 FEET APART.
7 SECURE VENT PIPE TO
6 VENT PIPE MUST PROJECT 51 MIN AND 64 MAX ABOVE ROOF FOR PROPER FIT AND FUNCTION. ADD S-1 (116666-01-CHT SEAL-VENT PIPE) AROUND PIPE ON ROOF BEFORE VENT CAP IS INSTALLED.
5. SEAL AROUND SHOWER WITH SILICONE.
4 USE SMOOTH PLUMBERS PUTTY 167459-01-000 TO SEAL STRAINER (0.2 PER STRAINER).
3. ALL PIPE AND FITTINGS TO BE ASSEMBLED WITH SOLVENT 004020-01-000 (USA), 004020-02-000 (CAN)
2. SLOPE OF TRAP ARM MUST BE 6 PER 305 mm.
1. SLOPE OF HORIZONTAL PIPING TO BE MINIMUM OF 3 PER 305 mm.
11 GLUE FITTING AFTER CABINET IS INSTALLED.
10 APPLY PRIMER 126427-02-000 AND CEMENT 126427-01-000 BETWEEN ELBOW AND FLEX PIPE.
12 REQUIRES 5 GALLONS RV ANTIFREEZE 182955-01-000 PER TOILET. FOLLOW TECMA TOILET WINTERIZATION PROCEDURE.
103
291
*1
84
46
9 *
29-Aug-2014
A
2
C
DO NOT SCALE DRAWING
D
PART NO
C
DWGNO
1
REV
5
5
A
4
D
16
8
B
3
7
TITLE:
SHEET
8
3 2
7
6
4
B
FIRST USED
14 R42QD
2
184469
DRAINAGE SYSTEM INSTL
184469
WASTE ASMSUPPLIED W/FAUCETNUT130403-01-000
180
12
C-3
1300
E-2
TOILET-SILENCE170062-01-CHT
VIEW A
DETAIL F(SHOWN W/OUT CABINETS AND FLOOR)1
1940
C-3
CP-2
1540
G-1
175
C-3
E-6
P-3
265
Y-1
A-151B1
1B1
150
21S
P-1
1B1
1975
265
T-1
1160
155
1690
1B11765
1220
E-6
P-1
P-3
E-6
A-15DETAIL H
DETAIL H
6
VM-1
7
21S
21S
21S
CP-3
21M21M
21S
1100
*1
84
46
9 *
4320
29-Aug-2014
A
2
C
DO NOT SCALE DRAWING
D
PART NO
C
DWGNO
1
REV
5
5
A
4
D
16
8
B
3
7
TITLE:
SHEET
8
3 2
7
6
4
B
FIRST USED
14 R42QD
3
184469
DRAINAGE SYSTEM INSTL
184469
1330
1755
1145
VIEW C(ROTATED)
VIEW B
3480
DETAIL E(SHOWN W/OUT CABINETS AND FLOOR)
STRAP-CONDUIT,2"008406-01-000
DETAIL E
36000
12430
G-1 C-3
G-1
155
G-1
G-1
155
P-3
WASTE-CONTINUOUS011091-04-000
SINK-GALLEY173783-01-CHTSTRAINER092303-01-000 (2)NUT130403-01-000WASHER-RUBBER127440-02-CHTANGLE-W/SLOTS140002-01-CHT (10)
215
214
A-15
W-2
265
1B1
1B1
P-1
E-5
G-1
E-6
175
1240
E-1
1330
T-11120
WASTE ASMSUPPLIED W/FAUCET
265 P-3
1B1
1B1
A-15
P-1
T-1
TOILET-SILENCE170062-01-CHT12
DISHWASHER-HOSE SUPPORT(SUPPLIED W/DISHWASHER)
DISHWASHER-DRAWER146340-03-CHT(REF)
175
C-3
A-13
E-6
DETAIL L
E-6
E-3
DETAIL L
(SHOWN W/OUT SHOWER)
SHOWER COMP184184-02-XXXSTRAINER066440-01-000
T-4
ADAPTER-ANGLE 165406-02-000
TRAP-WATERLESS,1-1/2"165406-01-000
A-151
70C-3 3580
170
DETAIL M(SHOWN W/OUT CABINETS)
DETAIL M
ELBOW136111-01-000 (2)
ELBOW136111-01-000 (2)
A-13
A-13
A-13
1450
195
165
150
1125
E-6
STRAP-CONDUIT,2"008406-01-000 (2)
PLYWOOD173882-0Z-03U (4)
E-6
1605
170
PL-1B-2
C-3
E-5
STRAP-CONDUIT,2"008406-01-000
STRAP-CONDUIT,2"008406-01-000 (2)
103
4
10
10T-1
1110
400
268
E-6
C-3
1680
VM-1
1420
1B1 265
7
7
77
7
E-3
E-2
175
E-6
190 1
55C-3
175
E-2
11495
1275
CP-2 6
*1
84
46
9 *
71
4152
29-Aug-2014
A
2
C
DO NOT SCALE DRAWING
D
PART NO
C
DWGNO
1
REV
5
5
A
4
D
16
8
B
3
7
TITLE:
SHEET
8
3 2
7
6
4
B
FIRST USED
14 R42QD
4
184469
DRAINAGE SYSTEM INSTL
184469
FRONTAXLE
VEHICLE
VALVE-SEWER HOSE144728-01-000CLAMP-HOSE62401-09-000
H-2
TOP VIEW SHOWING TANKS AND DRAINS
81
1222
146 141
54086017
5632
1422
PLATFORM-HOLDING TANK126714-49-000
9PC
TANK-HOLDING,71 GAL174852-02-000
BRACKET-ASM TANK158968-09-CHT158968-05-CHT
179
9PA
TANK ASM-HOLDING,51 GAL161224-06-000
*1
84
46
9 *
BRACKET-DRAINAGE TANK146080-02-CHT (2)
BRACKET ASM-HOLDING TANK163110-01-CHT
E-18
E-18
C-2
V-11 C-2
N-3
N-3
CP-1
265
2115
VIEW G
HANGER-TANK,SUPPORT187799-01-CHTSCREW000G39-10-12U(3)
9PC
9PC
9PA
29-Aug-2014
J
J
6
A
1
CHKR
DO NOT SCALE DRAWING
4
ONE-PLACE (X.X)
SHEET
7
REV
DWGNO
DFTR
1
MATERIAL:
DSNR
REV
TWO-PLACE (X.XX)
5
ZONE
A
ANGLE
6 5
8
REFER TO ES0018 FOR FASTENERTIGHTENING GUIDELINES
WHOLE DIM (X)
4
REVISION RECORD
FIRST USEDM.E.
C
B
TITLE:
OF
C
DATE
3
DFTR-ORIG
2
THIRD ANGLE
D
REV
D
P.E.
ORIG. DATE
B
DATE
UNSPECIFIED TOLERANCES ARE:
COPYRIGHT 2014WINNEBAGO
INDUSTRIES, INC.
2 REF:
ALL DIMENSIONS ARE IN MILLIMETERS
8
PROJECTION
7
3
PART NO
A
14 R42QD
1.5
0.50
1
1 4
3
184897
WATER SYSTEM INSTL
RELEASE
184897
DA
21M WASHER/DRYER PREP
214 DISHWASHER-DRAWER STYLE
215 DISHWASHER WITHOUT
505 HOSE REEL-WATER,POWERED
WATER TANK INSTL-REFSEE FRAME ASM-CHASSIS
21S WASHER & DRYER-PAIR
CALLOUTSSEE DWG NO
116230-01-000
FORWATER
NOTES:
8. ALL CRIMP FITTINGS TO PEX TUBING REQUIRE 1/2" CLAMP 140171-03-000.
7. ALL CRIMP FITTINGS TO PEX TUBING REQUIRE 5/8" CLAMP 140171-04-000.
6 LABEL HOT AND COLD SUPPLY TUBES AND TAPE FITTING TO TUBE BEFORE CABINET SET TO PREVENT MOVEMENT.
5 ADD PIPE WRAP (LADDER SCRAP 110157-02-000) INSULATION.
4 ADD TEFLON TAPE 010405-02-000.
3. ALL TUBING TO BE SECURED AT 1200 INTERVALS MAXIMUM WITH CLAMP 010495-01-000 AND SCREW 000G67-10-12U OR EQUIVALENT.
2. TUBING TO BE INSTALLED WITH SUFFICIENT SLOPE TO PROVIDE DRAINAGE TO NEAREST VALVE.
1. PLASTIC FITTINGS TO BE SEALED WITH SEALANT 084456-01-000.X-X
9. FLUSHING SYSTEM REQUIRES 125697-06-000 INSTRUCTION SHEET.
10 VALVE MUST REMAIN OPEN AFTER WATER TEST.
11. REQUIRES 5 GALLONS OF 182955-01-000 ANTIFREEZE FOR WINTERIZATION.
13 FOR INSTALLATION USE SILICON-ADHESIVE 131264-05-CHT. APPLY ON TOP OF PLATE, PLACE COVER ON, AND PUT ADHESIVE AROUND COVER.
12 INSTALL FAUCET WITHOUT BASEPLATE.
*1
84
89
7 *
TAILGATE PACKAGE9PC
04-Aug-2014
A
2
C
DO NOT SCALE DRAWING
D
PART NO
C
DWGNO
1
REV
5
5
A
4
D
16
8
B
3
7
TITLE:
SHEET
8
3 2
7
6
4
B
FIRST USED
14 R42QD
2
184897
WATER SYSTEM INSTL
184897
DETAIL K
TU10 95
*1
84
89
7 *
FAUCET178237-01-CHT
S-1S-1
VIEW ADETAIL B
(SHOWN W/OUT CABINETS)
E-29 DETAIL B
DETAIL C(SHOWN W/OUT CABINETS)
TU-94740
DETAIL C
DETAIL K(SHOWN W/OUT CABINETS)
TU104685
E-10
TU10675
4
PL-3TU-91370
E-44
TU101300
E-46
E-46
R-8
214
TU-945
V-22
4A-28
T-25
214
TO DISHWASHER
FAUCET-WATER PURIFIER173603-01-CHT
214
TU-950
TU1090
TU-5415
TU-5220
CLAMP-CLOSED010495-04-000 (4)
FAUCET-GALLEY190368-06-CHT
V-15
FILTER KIT160946-01-000
BREAKER-VACUUM125697-04-000CHECK VALVE125697-03-000
TU101200
TU-93075
E-46
DETAIL N
TU-5950
DETAIL N
214
T-28
A-27
A-27
4
E-44
TU10205
T-29
E-44
215
A-26
A-26
E-43
A-27
CLAMP-CLOSED010495-04-000
TU1055
TU1060
214
E-44
214
T-24
TU-5180
12
214
T-29
12
CI-1
BRACKET-SHOWER143101-01-CHT
04-Aug-2014
A
2
C
DO NOT SCALE DRAWING
D
PART NO
C
DWGNO
1
REV
5
5
A
4
D
16
8
B
3
7
TITLE:
SHEET
8
3 2
7
6
4
B
FIRST USED
14 R42QD
3
184897
WATER SYSTEM INSTL
184897
E-43
TU-965
TU-975E-43
TU1070
T-28
VIEW F
DETAIL G(SHOWN W/OUT CABINETS)
TU-514000
DETAIL G
DETAIL HTU-91130
DETAIL H
SECTION J-J(ROTATED)
DETAIL EVIEW D
(ROTATED)
DETAIL E
FAUCET-VALVE, SHOWER144596-01-CHTFAUCET-TRIM KIT144596-02-CHT
SHOWER-HAND HELD187372-01-CHT
BRACKET-SHOWER HEAD143218-03-CHTDROP ELL135028-02-CHTPLATE-COVER189861-01-XXX
N-1
143
787
TO ICEMAKER
TU-9720
TU1040
E-44
FAUCET178237-01-CHT
TU-9780
T-28
S-1
TU10820
S-1
TU-940
E-43
TU1085
E-43
FAUCET098419-01-000 (2)
TU-9180
T-28
21S
E-46
E-46
S-1
TU-92815
TU102690
T-28
T-28
TO TOILET
A-28
E-43S-1E-46
TU101120
TU-990
TU-5100
V-15
VACUUM BREAKER176678-01-CHT
TU-5150
1-315L
1-2
1-1
15L
10
15L
15L
E-43
TU-91100
TU101180
TU-9180
TU-940
TU1040
TU-9215
TU-550
T-24
15L
15L
E-43
E-43
TU10225
12
TU10180
TU-81315
A-262
CLAMP010495-04-000 (2)RIVET113133-03-CHT (2)
PL-421M
21M
21S
21SPL-4
A-262
CLAMP-CLOSED010495-04-000 (2)
T-28
A-282
T-28
*1
84
89
7 *
A-282
13
04-Aug-2014
A
2
C
DO NOT SCALE DRAWING
D
PART NO
C
DWGNO
1
REV
5
5
A
4
D
16
8
B
3
7
TITLE:
SHEET
8
3 2
7
6
4
B
FIRST USED
14 R42QD
4
184897
WATER SYSTEM INSTL
184897
VIEW L
WATER PUMP CENTER ASM182945-03-XXX
WATER CENTER ASM157511-28-XXX
HOSE-REEL,POWERED142675-01-CHTBRACKET145758-01-CHTRIVET118626-01-CHT (4)SCREW000G39-10-20U (2)
SERVICE CTR ASM163268-23-XXX
505
E-43
TU-9295
TU-82070
TU10250
E-43
E-44
TU101565
TU-91520
TU1070
TU-975
T-28
T-28
TO FURNACE-HYDRONIC
SHOWING LINES UNDER FLOOR L
TU-92000
TU102100
TU10880
TU-9950
TU-9220
E-44
PORT-SPRAY184487-01-CHT
P
PANEL ASM-CLOSEOUT175659-06-CHTSCREW000G39-10-10U(2)
A-28
P
VIEW M
E-43
TU10155
TU-9160
M
TU-91960
*1
84
89
7 *
TU-91940
SECTION P-P(ROTATED)
TU-91700
COVER-VALVE,BYPASS184242-02-CHTSCREW000G39-10-10U(8)
PANEL-PUMP,WATER184185-01-CHTSCREW000G39-10-10U(4)
CLAMP010495-04-000(4)RIVET113133-03-CHT(4)
9PC
9PC
9PC
PANEL-PUMP,WATER184241-01-CHTSCREW000G39-10-10U(3)
IN OU
T
04-Aug-2014