LABORELEC © 14/03/2011 LABORELEC ©

Chaire académique ORES "Smart Grids-Smart Metering"

A Power Line Communication Measuring Toolbox for the Distribution Grid Dries Lemmens

Page 3: A Power Line Communication Measuring Toolbox for the …€¦ · Smart Metering & Power Line Communication To summarize, Laborelec : Investigated Power Line Communications for more

LABORELEC © 3

PLC Communication for Smart Metering

PLC Communication as an answer to:

“How can we read out a meter in an efficient

and reliable way?”

External

Eandis, Ores and Sibelga

Laborelec Team:

Wim Foubert

Rafael Jahn

Dries Lemmens

Philip Vergeylen

Page 4: A Power Line Communication Measuring Toolbox for the …€¦ · Smart Metering & Power Line Communication To summarize, Laborelec : Investigated Power Line Communications for more

LABORELEC © 4

Smart Metering & Power Line Communication (PLC)

General topology:

3

Focus of Laborelec

Smart metering allows automatic

bidirectional information transfer

Gateway Metering

Operation Center

Page 5: A Power Line Communication Measuring Toolbox for the …€¦ · Smart Metering & Power Line Communication To summarize, Laborelec : Investigated Power Line Communications for more

LABORELEC © 5

PLC for Smart Metering

Cable / Overhead

line

House

~

Signal source

(data concentrator)

MV/LV

The signal source is limited in power and

signal voltage

The signal source sends a signal

with a certain power and certain

voltage amplitude on the grid

Page 6: A Power Line Communication Measuring Toolbox for the …€¦ · Smart Metering & Power Line Communication To summarize, Laborelec : Investigated Power Line Communications for more

LABORELEC © 6

PLC for Smart Metering

Impedance/Attenuation

Cable/Overhead

line

House

~

Signal source

(data concentrator)

MV/LV

The signal source is limited in power and

signal voltage

Some signal power is dissipated

in MV/LV transformer and

parallel feeders…

Page 7: A Power Line Communication Measuring Toolbox for the …€¦ · Smart Metering & Power Line Communication To summarize, Laborelec : Investigated Power Line Communications for more

LABORELEC © 7

PLC for Smart Metering

Impedance/Attenuation

Cable/Overhead

line

House

~

Signal source

(data concentrator)

MV/LV

The signal source is limited in power and

signal voltage

The Signal Voltage is attenuated

by the series impedance of the

cable/line

Page 8: A Power Line Communication Measuring Toolbox for the …€¦ · Smart Metering & Power Line Communication To summarize, Laborelec : Investigated Power Line Communications for more

LABORELEC © 8

PLC for Smart Metering

Issues:

Cable/Overhead

line

House

~

Signal source

(data concentrator)

MV/LV

The signal source is limited in power and

signal voltage

The signal is too small, the smart

meter can not read it anymore…

Problem!

Page 9: A Power Line Communication Measuring Toolbox for the …€¦ · Smart Metering & Power Line Communication To summarize, Laborelec : Investigated Power Line Communications for more

LABORELEC © 9

PLC for Smart Metering

Noise Issue:

9

Cable/Overhead

line

House

~

Signal source

(data concentrator)

MV/LV

The signal source is limited in power and

signal voltage

High Frequency noise influences

the signal quality Meter

cannot read the signal

anymore…

Page 10: A Power Line Communication Measuring Toolbox for the …€¦ · Smart Metering & Power Line Communication To summarize, Laborelec : Investigated Power Line Communications for more

LABORELEC © 10

Smart Metering & Power Line Communication

Project

Focus on the ‘physical layer’ in CENELEC A-band (3-95 kHz) et < 500 kHz

Investigation and assistance to DNO on performance of PLC Communication

Grid topology

Impedance and Transfer at high frequency

Noise at high frequency

Realized through

On-site measurements

Laboratory investigation

Theoretical research and simulations

Development of measurement system

Page 11: A Power Line Communication Measuring Toolbox for the …€¦ · Smart Metering & Power Line Communication To summarize, Laborelec : Investigated Power Line Communications for more

LABORELEC © 11

PLC: Measurement Device

PC with NI Acquisition card

PLC Switchbox (LBE)

HF Amplifier (LBE)

HF Current Clamps

Software Package (LBE)

Page 12: A Power Line Communication Measuring Toolbox for the …€¦ · Smart Metering & Power Line Communication To summarize, Laborelec : Investigated Power Line Communications for more

LABORELEC © 12

PLC Measuring Portfolio: Overview

Noise

Median/avg

treatment

Periodic

treatment

Time domain

treatment

Stationary noise

(i.e. statistically

most apparent),

no events

Periodic noise

Focus on 50 Hz

cycle –repetitive

phenomena

Linking time

domain 50 Hz

behaviour with

freq. domain

Impedance

& Transfer

Transfer Average

Impedance

Periodic

Impedance

2-point

measurement,

synchronisable

between devices

Sweep method

with 100 ms fft

window

Sweep method

with 100 us fft

window with 50

Hz synchro

Advanced

50 Hz synchro

Page 13: A Power Line Communication Measuring Toolbox for the …€¦ · Smart Metering & Power Line Communication To summarize, Laborelec : Investigated Power Line Communications for more

LABORELEC © 13

PLC Measuring Portfolio: Noise (Noise Stationary)

The stationary noise is the average noise during a 5-seconds measurement

Noise

Median/avg

treatment

Stationary noise

(i.e. statistically

most apparent),

no events GSR-HF

Page 14: A Power Line Communication Measuring Toolbox for the …€¦ · Smart Metering & Power Line Communication To summarize, Laborelec : Investigated Power Line Communications for more

LABORELEC © 14

PLC Measuring Portfolio: Noise (Noise Stationary)

Output: 3D Noise frequency time view

Noise

Median/avg

treatment

Stationary noise

(i.e. statistically

most apparent),

no events

dBV/Hz

Page 15: A Power Line Communication Measuring Toolbox for the …€¦ · Smart Metering & Power Line Communication To summarize, Laborelec : Investigated Power Line Communications for more

LABORELEC © 15

PLC Measuring Portfolio: Noise (Noise Stationary)

Output: Noise frequency view

Noise

Median/avg

treatment

Stationary noise

(i.e. statistically

most apparent),

no events

Page 16: A Power Line Communication Measuring Toolbox for the …€¦ · Smart Metering & Power Line Communication To summarize, Laborelec : Investigated Power Line Communications for more

LABORELEC © 16

PLC Measuring Portfolio: Noise (Noise Stationary)

Output: Overview of long-term campaign (6 days example)

Noise

Median/avg

treatment

Stationary noise

(i.e. statistically

most apparent),

no events

Page 17: A Power Line Communication Measuring Toolbox for the …€¦ · Smart Metering & Power Line Communication To summarize, Laborelec : Investigated Power Line Communications for more

LABORELEC © 17

PLC Measuring Portfolio: Impedance (Impedance Stationary)

The stationary impedance is the average impedance during a 20 seconds measurement Impedance

& Transfer

Average

Impedance

Sweep method

with 100 ms fft

window GSR-HF

Page 18: A Power Line Communication Measuring Toolbox for the …€¦ · Smart Metering & Power Line Communication To summarize, Laborelec : Investigated Power Line Communications for more

LABORELEC © 18

PLC Measuring Portfolio: Impedance (Impedance Stationary)

Output: 2D Impedance Frequency view Impedance

& Transfer

Average

Impedance

Sweep method

with 100 ms fft

window

Page 19: A Power Line Communication Measuring Toolbox for the …€¦ · Smart Metering & Power Line Communication To summarize, Laborelec : Investigated Power Line Communications for more

LABORELEC © 19

PLC Measuring Portfolio: Transfer (Transfer Function)

The transfer function is measured by injecting and measuring a signal on one location and another measurement on a different location

Impedance

& Transfer

Transfer

2-point

measurement,

synchronisable

between devices GSR-HF1 GSR-HF2

Page 20: A Power Line Communication Measuring Toolbox for the …€¦ · Smart Metering & Power Line Communication To summarize, Laborelec : Investigated Power Line Communications for more

LABORELEC © 20

PLC Measuring Portfolio: Transfer (Transfer Function)

Output:

Impedance

& Transfer

Transfer

2-point

measurement,

synchronisable

between devices

20 30 40 50 60 70 80 90 100 110 120-16

-14

-12

-10

-8

-6

-4

-2

0

2

Frequency (kHz)

20*l

og10(a

bs(c

hannel re

sponse))

Transfer function: End of line --> Substation

Transfer function: Substation --> End of line

Page 21: A Power Line Communication Measuring Toolbox for the …€¦ · Smart Metering & Power Line Communication To summarize, Laborelec : Investigated Power Line Communications for more

LABORELEC © 21

Laboratory-measurements in the Faraday Cage

LISN = Line Impedance Stabilizing Network

4/18/2013 © LABORELEC

LISN FILTER DUT

Coupling

Circuit

Signal

Injection

V I

Faraday Cage

Why LISN ?

- Creates a noise free

grid

- Input impedance =

5-10 Ω @ 20-120 kHz

Noise free grid

GSR-HF

Page 22: A Power Line Communication Measuring Toolbox for the …€¦ · Smart Metering & Power Line Communication To summarize, Laborelec : Investigated Power Line Communications for more

LABORELEC © 22

PLC: Load Measurements

Example: Investigation of loads – Saving lights

Impedance measurements

This load ‘short-circuits’ the signal

periodically in a 50 Hz – cycle !

Page 23: A Power Line Communication Measuring Toolbox for the …€¦ · Smart Metering & Power Line Communication To summarize, Laborelec : Investigated Power Line Communications for more

LABORELEC © 23

Smart Metering & Power Line Carrier – Communication (PLC)

Examples: Investigation on MV/LV transformers

Measurements done on decoupled devices

Modelization done

Page 24: A Power Line Communication Measuring Toolbox for the …€¦ · Smart Metering & Power Line Communication To summarize, Laborelec : Investigated Power Line Communications for more

LABORELEC © 24

PLC: Load Measurements

Noise is also produced by new type of loads

Electric Vehicle

Noise pollution and impedance during charging

LEDs

Page 25: A Power Line Communication Measuring Toolbox for the …€¦ · Smart Metering & Power Line Communication To summarize, Laborelec : Investigated Power Line Communications for more

LABORELEC © 25

PLC in 2012: Focus on material

Testing prototypes

New PLC modems were tested in the lab and in the field in Rode

Result: Provided feedback to Engineering for the choice of frequencies

“Sniffing” PLC

PLC Spy/Sniffer provides complementary information to draw conclusions about the quality of PLC

Result: Match communication statistics with noise, impedance measurements

Page 26: A Power Line Communication Measuring Toolbox for the …€¦ · Smart Metering & Power Line Communication To summarize, Laborelec : Investigated Power Line Communications for more

LABORELEC © 26

PLC in 2012: Focus on Troubleshooting

PLC Experiments

Reproducing grid situations in the lab

Result: Ability to test smart metering material in the lab

Communication statistics for AIM (Ores)

Analyze and report on communication quality and reliability

Result: Ability to focus on specific problematic locations by analyzing collected data from the smart metering system

Unreachable meters in Aye (Ores)

Ad-hoc measurements in substations and a specific house

Result: Ongoing analysis and report on the specific situation

Page 27: A Power Line Communication Measuring Toolbox for the …€¦ · Smart Metering & Power Line Communication To summarize, Laborelec : Investigated Power Line Communications for more

LABORELEC © 27

Next steps in 2013

Emerging PLC Technologies

OFDM in PRIME and G3

QPSK for Eandis

G3 PLC over MV

Building up knowledge and learn from experiences within the DNO’s

PLC Troubleshooting

Ad-hoc measurement campaigns to study specific problems

Smart Meter data analysis

Analyze the huge amount of information available from the smart metering systems. Focus on problems!

Page 28: A Power Line Communication Measuring Toolbox for the …€¦ · Smart Metering & Power Line Communication To summarize, Laborelec : Investigated Power Line Communications for more

LABORELEC © 28

Smart Metering & Power Line Communication

To summarize, Laborelec :

Investigated Power Line Communications for more than 4 years, beginning from scratch, to compensate the lack of supplier’s expertise

Gained insight in the behavior of the physical signal in typical grids

Aids the DNO with the testing and evaluation of the performance of prototypes and in first smart metering pilots

Page 29: A Power Line Communication Measuring Toolbox for the …€¦ · Smart Metering & Power Line Communication To summarize, Laborelec : Investigated Power Line Communications for more

LABORELEC © 29

Smart Metering & Power Line Communication

Any questions or remarks?

Email: [email protected]

Page 30: A Power Line Communication Measuring Toolbox for the …€¦ · Smart Metering & Power Line Communication To summarize, Laborelec : Investigated Power Line Communications for more

© LABORELEC

LABORELEC BELGIUM Rodestraat 125 1630 Linkebeek Belgium T. +32 2 382 02 11 F. +32 2 382 02 41 RPR/RPM Brussels 0400.902.582 BTW/TVA BE 0400 902 582

www.laborelec.com [email protected]

LABORELEC THE NETHERLANDS Amerikalaan 35 6199 AE Maastricht-Airport The Netherlands T. +31 63 88 26 022

© LABORELEC

LABORELEC GERMANY Brombergerstrasse 39-41, 42281 Wuppertal Germany T. +49 202 250 27 13 T. +49 202 250 27 15

FROM INNOVATION TO OPERATIONAL ASSISTANCE IN ENERGY

Laborelec is a leading research and services centre in energy processes and energy use, with more than fifty years of experience. We are part of the Research and Innovation Division of the GDF SUEZ Group, a world leader in the energy sector.

FIVE REASONS FOR YOU TO CHOOSE LABORELEC

Wide range of technical competences in Electricity Generation, Grids and End-Use

Increased profitability and sustainability of your energy processes and assets

Unique combination of contract research and operational assistance

Independent advice based on certified laboratory and field analyses all over the world

More than 50 years of experience