25
E E F F 9 9 10 10 K.2 K.2 NEW DUCT PENTRATION, RE: A3/A310 ,F.V. 12'-4" 12'-4" ,F.V. 1 PROJECT NUMBER: 1900 W. 47th Place Suite 300 Westwood, Kansas 66205 p: 913.362.6500 www.pgav.com Structural Engineers 4338 Bellview Avenue Kansas City, MO 64111 BOB D. CAMPBELL & CO, INC. (816) 531-4144 Plumbing and Mechanical Engineers 6 South Old Orchard St Louis, MO 63119 ROSS & BARUZZINI, INC. (314) 918-8383 Electrical Engineers 1600 Genessee St, Suite 260 Kansas City, MO 64102 ANTELLA CONSULTING ENGINEERS, INC. (816) 421-0950 11/19/15 53417 Medical Science Renovate 7th Floor West Laboratories UNIVERSITY OF MISSOURI FOR: The Curators of the University of Missouri - Project No: CP151661 ADDENDUM 01 XA-01 1/8" = 1'-0" A1/A310 ROOF PLAN 1

A1/A310 - Contact Us | Campus Facilities | University of ...operations-webapps.missouri.edu/pdc/adsite/projects/cp151661/... · 1/8" = 1'-0" A1/A310 ... SUBSTITUTION REQUEST (During

Embed Size (px)

Citation preview

Page 1: A1/A310 - Contact Us | Campus Facilities | University of ...operations-webapps.missouri.edu/pdc/adsite/projects/cp151661/... · 1/8" = 1'-0" A1/A310 ... SUBSTITUTION REQUEST (During

E

E

F

F

9 9

10 10

K.2 K.2

NEW DUCT PENTRATION,

RE: A3/A310

,F.V.

12'-4"

12'-4" ,F.V.

1

PROJECT NUMBER:

1900 W. 47th Place

Suite 300

Westwood, Kansas

66205p: 913.362.6500www.pgav.com

Structural Engineers4338 Bellview AvenueKansas City, MO 64111

BOB D. CAMPBELL & CO, INC.

(816) 531-4144

Plumbing and Mechanical Engineers6 South Old OrchardSt Louis, MO 63119

ROSS & BARUZZINI, INC.

(314) 918-8383

Electrical Engineers1600 Genessee St, Suite 260Kansas City, MO 64102

ANTELLA CONSULTING ENGINEERS, INC.

(816) 421-0950

11/19/1553417

Medical Science Renovate 7th Floor West Laboratories

UNIVERSITY OF MISSOURIFOR: The Curators of the University of Missouri - Project No: CP151661

ADDENDUM 01

XA-01

1/8" = 1'-0" A1/A310ROOF PLAN

1

Page 2: A1/A310 - Contact Us | Campus Facilities | University of ...operations-webapps.missouri.edu/pdc/adsite/projects/cp151661/... · 1/8" = 1'-0" A1/A310 ... SUBSTITUTION REQUEST (During

E

E

D

D

1 1

2 2

3 3

16'-4 1/2"

NEW DUCT PENTRATION, RE: A3/A310

PATCH ALL EXISTING PENTRATIONS

ASSOCIATED WITH REMOVED DUCTWORK

25'-7" , F.V.

12'-0" , F.V.

5'-6"

1

PROJECT NUMBER:

1900 W. 47th Place

Suite 300

Westwood, Kansas

66205p: 913.362.6500www.pgav.com

Structural Engineers4338 Bellview AvenueKansas City, MO 64111

BOB D. CAMPBELL & CO, INC.

(816) 531-4144

Plumbing and Mechanical Engineers6 South Old OrchardSt Louis, MO 63119

ROSS & BARUZZINI, INC.

(314) 918-8383

Electrical Engineers1600 Genessee St, Suite 260Kansas City, MO 64102

ANTELLA CONSULTING ENGINEERS, INC.

(816) 421-0950

11/19/1553417

Medical Science Renovate 7th Floor West Laboratories

UNIVERSITY OF MISSOURIFOR: The Curators of the University of Missouri - Project No: CP151661

ADDENDUM 01

XA-02

1/8" = 1'-0" A1/A310ROOF PLAN

Page 3: A1/A310 - Contact Us | Campus Facilities | University of ...operations-webapps.missouri.edu/pdc/adsite/projects/cp151661/... · 1/8" = 1'-0" A1/A310 ... SUBSTITUTION REQUEST (During

L

L

13 13

14 14

K.1

K.1

J.1

J.1

3'-6" , F.V.

3'-6" , F.V.

NEW DUCT PENTRATION,

RE: A3/A310

6'-1" , F.V.

1

PROJECT NUMBER:

1900 W. 47th Place

Suite 300

Westwood, Kansas

66205p: 913.362.6500www.pgav.com

Structural Engineers4338 Bellview AvenueKansas City, MO 64111

BOB D. CAMPBELL & CO, INC.

(816) 531-4144

Plumbing and Mechanical Engineers6 South Old OrchardSt Louis, MO 63119

ROSS & BARUZZINI, INC.

(314) 918-8383

Electrical Engineers1600 Genessee St, Suite 260Kansas City, MO 64102

ANTELLA CONSULTING ENGINEERS, INC.

(816) 421-0950

11/19/1553417

Medical Science Renovate 7th Floor West Laboratories

UNIVERSITY OF MISSOURIFOR: The Curators of the University of Missouri - Project No: CP151661

ADDENDUM 01

XA-03

1/8" = 1'-0" A1/A310ROOF PLAN

Page 4: A1/A310 - Contact Us | Campus Facilities | University of ...operations-webapps.missouri.edu/pdc/adsite/projects/cp151661/... · 1/8" = 1'-0" A1/A310 ... SUBSTITUTION REQUEST (During

LEVEL FIVE50' - 7 3/8"

LEVEL SIX61' - 9 3/4"

LEVEL SEVEN73' - 0 1/8"

ROOF84' - 2 1/2"

6 87

T.O. PARAPET89' - 1 5/8"

A

EXISTING

STROBIC FAN, TYP.

PENTHOUSE ROOF97' - 6 1/2"

B

1

PROJECT NUMBER:

1900 W. 47th Place

Suite 300

Westwood, Kansas

66205p: 913.362.6500www.pgav.com

Structural Engineers4338 Bellview AvenueKansas City, MO 64111

BOB D. CAMPBELL & CO, INC.

(816) 531-4144

Plumbing and Mechanical Engineers6 South Old OrchardSt Louis, MO 63119

ROSS & BARUZZINI, INC.

(314) 918-8383

Electrical Engineers1600 Genessee St, Suite 260Kansas City, MO 64102

ANTELLA CONSULTING ENGINEERS, INC.

(816) 421-0950

11/19/1553417

Medical Science Renovate 7th Floor West Laboratories

UNIVERSITY OF MISSOURIFOR: The Curators of the University of Missouri - Project No: CP151661

ADDENDUM 01

XA-04

1/16" = 1'-0" A3/A400PARTIAL EXISTING WEST ELEVATION

Page 5: A1/A310 - Contact Us | Campus Facilities | University of ...operations-webapps.missouri.edu/pdc/adsite/projects/cp151661/... · 1/8" = 1'-0" A1/A310 ... SUBSTITUTION REQUEST (During

PROJECT NUMBER:

1900 W. 47th Place

Suite 300

Westwood, Kansas

66205p: 913.362.6500www.pgav.com

Structural Engineers4338 Bellview AvenueKansas City, MO 64111

BOB D. CAMPBELL & CO, INC.

(816) 531-4144

Plumbing and Mechanical Engineers6 South Old OrchardSt Louis, MO 63119

ROSS & BARUZZINI, INC.

(314) 918-8383

Electrical Engineers1600 Genessee St, Suite 260Kansas City, MO 64102

ANTELLA CONSULTING ENGINEERS, INC.

(816) 421-0950

11/19/1553417

Medical Science Renovate 7th Floor West Laboratories

UNIVERSITY OF MISSOURIFOR: The Curators of the University of Missouri - Project No: CP151661

ADDENDUM 01

XA-05

Page 6: A1/A310 - Contact Us | Campus Facilities | University of ...operations-webapps.missouri.edu/pdc/adsite/projects/cp151661/... · 1/8" = 1'-0" A1/A310 ... SUBSTITUTION REQUEST (During

PROJECT NUMBER:

1900 W. 47th Place

Suite 300

Westwood, Kansas

66205p: 913.362.6500www.pgav.com

Structural Engineers4338 Bellview AvenueKansas City, MO 64111

BOB D. CAMPBELL & CO, INC.

(816) 531-4144

Plumbing and Mechanical Engineers6 South Old OrchardSt Louis, MO 63119

ROSS & BARUZZINI, INC.

(314) 918-8383

Electrical Engineers1600 Genessee St, Suite 260Kansas City, MO 64102

ANTELLA CONSULTING ENGINEERS, INC.

(816) 421-0950

11/19/1553417

Medical Science Renovate 7th Floor West Laboratories

UNIVERSITY OF MISSOURIFOR: The Curators of the University of Missouri - Project No: CP151661

ADDENDUM 01

XA-06

Page 7: A1/A310 - Contact Us | Campus Facilities | University of ...operations-webapps.missouri.edu/pdc/adsite/projects/cp151661/... · 1/8" = 1'-0" A1/A310 ... SUBSTITUTION REQUEST (During

LEVEL FIVE

50' - 7 3/8"

LEVEL SIX61' - 9 3/4"

LEVEL SEVEN73' - 0 1/8"

ROOF84' - 2 1/2"

6 87

T.O. PARAPET89' - 1 5/8"

A

PENTHOUSE ROOF97' - 6 1/2"

B

1

PROJECT NUMBER:

1900 W. 47th Place

Suite 300

Westwood, Kansas

66205p: 913.362.6500www.pgav.com

Structural Engineers4338 Bellview AvenueKansas City, MO 64111

BOB D. CAMPBELL & CO, INC.

(816) 531-4144

Plumbing and Mechanical Engineers6 South Old OrchardSt Louis, MO 63119

ROSS & BARUZZINI, INC.

(314) 918-8383

Electrical Engineers1600 Genessee St, Suite 260Kansas City, MO 64102

ANTELLA CONSULTING ENGINEERS, INC.

(816) 421-0950

11/19/1553417

Medical Science Renovate 7th Floor West Laboratories

University of Missouri - Columbia

ADDENDUM 01

XA-07

1/8" = 1'-0" A2/A401PARTIAL EXISTING WEST ELEVATION

Page 8: A1/A310 - Contact Us | Campus Facilities | University of ...operations-webapps.missouri.edu/pdc/adsite/projects/cp151661/... · 1/8" = 1'-0" A1/A310 ... SUBSTITUTION REQUEST (During
Page 9: A1/A310 - Contact Us | Campus Facilities | University of ...operations-webapps.missouri.edu/pdc/adsite/projects/cp151661/... · 1/8" = 1'-0" A1/A310 ... SUBSTITUTION REQUEST (During

11/19/2015

Aluminum Windows

Manko Windows 3300 Series

085113

Medical Science 7th Floor West Lab

6

EFCO 6700

2.1 A

CP151661PGAV Architects

Aluminum Windows

Page 10: A1/A310 - Contact Us | Campus Facilities | University of ...operations-webapps.missouri.edu/pdc/adsite/projects/cp151661/... · 1/8" = 1'-0" A1/A310 ... SUBSTITUTION REQUEST (During

SUBSTITUTION

REQUEST

(During the Bidding Phase)

Project: Medical Science Renovate 7th Floor West Labs

University of Missouri – Columbia

To: Ms. Michelle Gangel

PGAV Architects

Re: Substitution Request

Substitution Request Number:

From: D.L. Neuner Company, Inc.

Date: November 11, 2015

A/E Project Number: CP151661

Contract For:

Specification Title: Door Hardware Description: Surface Closers

Section: 087100 Page: Article/Paragraph: 2.8 Proposed Substitution: Stanley Commercial Door Closers

Manufacturer: Address: Indianapolis, IN Phone: (800) 711-6814

Trade Name: Stanley Security Solutions Model No.: QDC100 Series Attached data includes product description, specifications, drawings, photographs, and performance and test data adequate for evaluation of the request; applicable portions of the data are clearly identified. Attached data also includes a description of changes to the Contract Documents that the proposed substitution will require for its proper installation. The Undersigned certifies:

Proposed substitution has been fully investigated and determined to be equal or superior in all respects to specified product.

Same warranty will be furnished for proposed substitution as for specified product.

Same maintenance service and source of replacement parts, as applicable, is available.

Proposed substitution will have no adverse effect on other trades and will not affect or delay progress schedule.

Proposed substitution does not affect dimensions and functional clearances.

Payment will be made for changes to building design, including A/E design, detailing, and construction costs caused by the substitution. Submitted by: David L. Neuner, Jr., CSI, CDT

Signed by:

Firm: D.L. Neuner Company, Inc.

Address: 3015 S. Brentwood Blvd.

St. Louis, MO 63144

Telephone: (800) 775-9455 A/E’s REVIEW AND ACTION

Substitution approved - Make submittals in accordance with Specification Section 01330. Substitution approved as noted - Make submittals in accordance with Specification Section 01330. Substitution rejected - Use specified materials. Substitution Request received too late - Use specified materials.

Signed by: Date:

Supporting Data Attached: Drawings X Product Data Samples Tests Reports

© Copyright 1996, Construction Specifications Institute,

99 Canal Center Plaza, Suite 300 Alexandria, VA 22314

Page of September 1996

CSI Form 1.5C

Page 11: A1/A310 - Contact Us | Campus Facilities | University of ...operations-webapps.missouri.edu/pdc/adsite/projects/cp151661/... · 1/8" = 1'-0" A1/A310 ... SUBSTITUTION REQUEST (During

SUBSTITUTION

REQUEST

(During the Bidding Phase)

Project: Medical Science Renovate 7th Floor West Labs

University of Missouri – Columbia

To: Ms. Michelle Gangel

PGAV Architects

Re: Substitution Request

Substitution Request Number:

From: D.L. Neuner Company, Inc.

Date: November 11, 2015

A/E Project Number: CP151661

Contract For:

Specification Title: Door Hardware Description: Stops/Flatgoods

Section: 087100 Page: Article/Paragraph: 2.10 Proposed Substitution: Trimco Hardware

Manufacturer: Address: Los Angeles, CA Phone: (323) 262-4191

Trade Name: Model No.: Attached data includes product description, specifications, drawings, photographs, and performance and test data adequate for evaluation of the request; applicable portions of the data are clearly identified. Attached data also includes a description of changes to the Contract Documents that the proposed substitution will require for its proper installation. The Undersigned certifies:

Proposed substitution has been fully investigated and determined to be equal or superior in all respects to specified product.

Same warranty will be furnished for proposed substitution as for specified product.

Same maintenance service and source of replacement parts, as applicable, is available.

Proposed substitution will have no adverse effect on other trades and will not affect or delay progress schedule.

Proposed substitution does not affect dimensions and functional clearances.

Payment will be made for changes to building design, including A/E design, detailing, and construction costs caused by the substitution. Submitted by: David L. Neuner, Jr., CSI, CDT

Signed by:

Firm: D.L. Neuner Company, Inc.

Address: 3015 S. Brentwood Blvd.

St. Louis, MO 63144

Telephone: (800) 775-9455 A/E’s REVIEW AND ACTION

Substitution approved - Make submittals in accordance with Specification Section 01330. Substitution approved as noted - Make submittals in accordance with Specification Section 01330. Substitution rejected - Use specified materials. Substitution Request received too late - Use specified materials.

Signed by: Date:

Supporting Data Attached: Drawings X Product Data Samples Tests Reports

© Copyright 1996, Construction Specifications Institute,

99 Canal Center Plaza, Suite 300 Alexandria, VA 22314

Page of September 1996

CSI Form 1.5C

Page 12: A1/A310 - Contact Us | Campus Facilities | University of ...operations-webapps.missouri.edu/pdc/adsite/projects/cp151661/... · 1/8" = 1'-0" A1/A310 ... SUBSTITUTION REQUEST (During
Page 13: A1/A310 - Contact Us | Campus Facilities | University of ...operations-webapps.missouri.edu/pdc/adsite/projects/cp151661/... · 1/8" = 1'-0" A1/A310 ... SUBSTITUTION REQUEST (During
Page 14: A1/A310 - Contact Us | Campus Facilities | University of ...operations-webapps.missouri.edu/pdc/adsite/projects/cp151661/... · 1/8" = 1'-0" A1/A310 ... SUBSTITUTION REQUEST (During

CFH 03 CFH 04

CYLCYL

F G

6

5

7

FEV

7-04B

1

1

S-1

200

FEV

7-04A

16"ø EA

12"ø EA

12"ø EA

12"ø EA 12"ø EA

FD

7-12

FD

7-13

1011

13

1

PROJECT NUMBER:

1900 W. 47th Place

Suite 300

Westwood, Kansas

66205p: 913.362.6500www.pgav.com

Structural Engineers4338 Bellview AvenueKansas City, MO 64111

BOB D. CAMPBELL & CO, INC.

(816) 531-4144

Plumbing and Mechanical Engineers6 South Old OrchardSt Louis, MO 63119

ROSS & BARUZZINI, INC.

(314) 918-8383

Electrical Engineers1600 Genessee St, Suite 260Kansas City, MO 64102

ANTELLA CONSULTING ENGINEERS, INC.

(816) 421-0950

11/19/1553417

Medical Science Renovate 7th Floor West Laboratories

UNIVERSITY OF MISSOURIFOR: The Curators of the University of Missouri No.: CP151661

ADDENDUM 01

XM-01

1/8" = 1'-0"M1/M1027TH FL. DUCTWORK NEW WORK

KEYED NOTES:

3 10" DIAMETER EXHAUST DUCT UP & DN IN NEW 2-HOURCHASE.

1

KEYED NOTES:

13 CAP DUCT JUST ABOVE 7TH FLOOR SLAB INSIDE NEWCHASE.

1

Page 15: A1/A310 - Contact Us | Campus Facilities | University of ...operations-webapps.missouri.edu/pdc/adsite/projects/cp151661/... · 1/8" = 1'-0" A1/A310 ... SUBSTITUTION REQUEST (During

E F G

8

9

10

K.2

NEW 20"ø DNTHROUGHNEW OPENINGIN ROOF

20"ø EA

24"ø EA

24"ø EA

1

PROJECT NUMBER:

1900 W. 47th Place

Suite 300

Westwood, Kansas

66205p: 913.362.6500www.pgav.com

Structural Engineers4338 Bellview AvenueKansas City, MO 64111

BOB D. CAMPBELL & CO, INC.

(816) 531-4144

Plumbing and Mechanical Engineers6 South Old OrchardSt Louis, MO 63119

ROSS & BARUZZINI, INC.

(314) 918-8383

Electrical Engineers1600 Genessee St, Suite 260Kansas City, MO 64102

ANTELLA CONSULTING ENGINEERS, INC.

(816) 421-0950

11/19/1553417

Medical Science Renovate 7th Floor West Laboratories

UNIVERSITY OF MISSOURIFOR: The Curators of the University of Missouri No.: CP151661

ADDENDUM 01

XM-02

1/8" = 1'-0"M1/M103ROOF NEW WORK PLAN

Page 16: A1/A310 - Contact Us | Campus Facilities | University of ...operations-webapps.missouri.edu/pdc/adsite/projects/cp151661/... · 1/8" = 1'-0" A1/A310 ... SUBSTITUTION REQUEST (During

F G

6

5

7

48"x24" UP

60"x14" EA DN

40"x14" UP &DN

10"x14" UP &DN

16"x10" EA DN

62"x20" SAUP/DN

40"x18" SA UP& DN

OFFICE

743B

SHOWER

703B

BATH

703A

EXAM ROOM

701

OFFICE

700

1

1

1 48"x24" EA DN 1

14

14

14

1

1

1

1

1

1

1

PROJECT NUMBER:

1900 W. 47th Place

Suite 300

Westwood, Kansas

66205p: 913.362.6500www.pgav.com

Structural Engineers4338 Bellview AvenueKansas City, MO 64111

BOB D. CAMPBELL & CO, INC.

(816) 531-4144

Plumbing and Mechanical Engineers6 South Old OrchardSt Louis, MO 63119

ROSS & BARUZZINI, INC.

(314) 918-8383

Electrical Engineers1600 Genessee St, Suite 260Kansas City, MO 64102

ANTELLA CONSULTING ENGINEERS, INC.

(816) 421-0950

11/18/1553417

Medical Science Renovate 7th Floor West Laboratories

UNIVERSITY OF MISSOURIFOR: The Curators of the University of Missouri No.: CP151661

ADDENDUM 01

XM-03

1/8" = 1'-0"M1/MD1027TH FL. DUCTWORK DEMO PLAN

KEYED NOTES:

14 DEMOLISH DUCT FROM PENTHOUSE TO JUST ABOVESEVENTH FLOOR SLAB AND CAP INSIDE NEW CHASE.

1

Page 17: A1/A310 - Contact Us | Campus Facilities | University of ...operations-webapps.missouri.edu/pdc/adsite/projects/cp151661/... · 1/8" = 1'-0" A1/A310 ... SUBSTITUTION REQUEST (During

T

T

T

F G

8

K.2

OFFICE

748

OFFICE

757

1 11 10"ø EA UP

1

PROJECT NUMBER:

1900 W. 47th Place

Suite 300

Westwood, Kansas

66205p: 913.362.6500www.pgav.com

Structural Engineers4338 Bellview AvenueKansas City, MO 64111

BOB D. CAMPBELL & CO, INC.

(816) 531-4144

Plumbing and Mechanical Engineers6 South Old OrchardSt Louis, MO 63119

ROSS & BARUZZINI, INC.

(314) 918-8383

Electrical Engineers1600 Genessee St, Suite 260Kansas City, MO 64102

ANTELLA CONSULTING ENGINEERS, INC.

(816) 421-0950

11/19/1553417

Medical Science Renovate 7th Floor West Laboratories

UNIVERSITY OF MISSOURIFOR: The Curators of the University of Missouri No.: CP151661

ADDENDUM 01

XM-04

1/8" = 1'-0"M1/MD1027TH FL. DUCTWORK DEMO PLAN

Page 18: A1/A310 - Contact Us | Campus Facilities | University of ...operations-webapps.missouri.edu/pdc/adsite/projects/cp151661/... · 1/8" = 1'-0" A1/A310 ... SUBSTITUTION REQUEST (During

E F G

8

9

10

K.2

36"ø EA

1

2

1

10"ø EA DN

PROJECT NUMBER:

1900 W. 47th Place

Suite 300

Westwood, Kansas

66205p: 913.362.6500www.pgav.com

Structural Engineers4338 Bellview AvenueKansas City, MO 64111

BOB D. CAMPBELL & CO, INC.

(816) 531-4144

Plumbing and Mechanical Engineers6 South Old OrchardSt Louis, MO 63119

ROSS & BARUZZINI, INC.

(314) 918-8383

Electrical Engineers1600 Genessee St, Suite 260Kansas City, MO 64102

ANTELLA CONSULTING ENGINEERS, INC.

(816) 421-0950

11/19/1553417

Medical Science Renovate 7th Floor West Laboratories

UNIVERSITY OF MISSOURIFOR: The Curators of the University of Missouri No.: CP151661

ADDENDUM 01

XM-05

1/8" = 1'-0"M1/MD103ROOF DEMOLITION PLAN

Page 19: A1/A310 - Contact Us | Campus Facilities | University of ...operations-webapps.missouri.edu/pdc/adsite/projects/cp151661/... · 1/8" = 1'-0" A1/A310 ... SUBSTITUTION REQUEST (During

T

G

856"x12" SA

2"LPR

3"HWR3"HWS

8"CWS

8"CWR

MECH ROOM

M750

1 1/2"

1 1/2"

1 1/2"

1 1/2"

2 1/2"

146

8

9

VAV 7-28

8"

8"

6"

6"

1

1

1

1

1

PROJECT NUMBER:

1900 W. 47th Place

Suite 300

Westwood, Kansas

66205p: 913.362.6500www.pgav.com

Structural Engineers4338 Bellview AvenueKansas City, MO 64111

BOB D. CAMPBELL & CO, INC.

(816) 531-4144

Plumbing and Mechanical Engineers6 South Old OrchardSt Louis, MO 63119

ROSS & BARUZZINI, INC.

(314) 918-8383

Electrical Engineers1600 Genessee St, Suite 260Kansas City, MO 64102

ANTELLA CONSULTING ENGINEERS, INC.

(816) 421-0950

11/19/1553417

Medical Science Renovate 7th Floor West Laboratories

UNIVERSITY OF MISSOURIFOR: The Curators of the University of Missouri No.: CP151661

ADDENDUM 01

XM-06

M2/M2013D VIEW MECH. RM.

8" CWS & CWR 1

1

1/4" = 1'-0"M1/M201ENLARGED MECH RM. PLAN

Page 20: A1/A310 - Contact Us | Campus Facilities | University of ...operations-webapps.missouri.edu/pdc/adsite/projects/cp151661/... · 1/8" = 1'-0" A1/A310 ... SUBSTITUTION REQUEST (During

T T

J K L

6

8

7

K.2

CONT RM

742

OFFICE

741

COPY RM

741D

OFFICE

741C

OFFICE

741B

OFFICE

741A

68"x9" HOT(TOP)

68"x10" COLD(BELOW)

1

11

1

1

1 1

T

B

BB

CC

C

C

11

11

PROJECT NUMBER:

1900 W. 47th Place

Suite 300

Westwood, Kansas

66205p: 913.362.6500www.pgav.com

Structural Engineers4338 Bellview AvenueKansas City, MO 64111

BOB D. CAMPBELL & CO, INC.

(816) 531-4144

Plumbing and Mechanical Engineers6 South Old OrchardSt Louis, MO 63119

ROSS & BARUZZINI, INC.

(314) 918-8383

Electrical Engineers1600 Genessee St, Suite 260Kansas City, MO 64102

ANTELLA CONSULTING ENGINEERS, INC.

(816) 421-0950

11/19/1553417

Medical Science Renovate 7th Floor West Laboratories

UNIVERSITY OF MISSOURIFOR: The Curators of the University of Missouri No.: CP151661

ADDENDUM 01

XM-07

1/8" = 1'-0"M1/MD1027TH FL. DUCTWORK DEMO. PLAN

Page 21: A1/A310 - Contact Us | Campus Facilities | University of ...operations-webapps.missouri.edu/pdc/adsite/projects/cp151661/... · 1/8" = 1'-0" A1/A310 ... SUBSTITUTION REQUEST (During

PROJECT NUMBER:

1900 W. 47th Place

Suite 300

Westwood, Kansas

66205p: 913.362.6500www.pgav.com

Structural Engineers4338 Bellview AvenueKansas City, MO 64111

BOB D. CAMPBELL & CO, INC.

(816) 531-4144

Plumbing and Mechanical Engineers6 South Old OrchardSt Louis, MO 63119

ROSS & BARUZZINI, INC.

(314) 918-8383

Electrical Engineers1600 Genessee St, Suite 260Kansas City, MO 64102

ANTELLA CONSULTING ENGINEERS, INC.

(816) 421-0950

11/19/1553417

Medical Science Renovate 7th Floor West Laboratories

UNIVERSITY OF MISSOURIFOR: The Curators of the University of Missouri No.: CP151661

ADDENDUM 01

XM-08

ALTERNATE 4 KEYEDNOTES:

A EXISTING DUAL DUCT VAV BOX TO REMAIN. THISPROJECT SHALL REPLACE EXISTING PNEUMATIC VAVBOX CONTROLS WITH NEW DDC ELECTRIC CONTROLS.REFER TO SHEET M704 FOR THE EXTENT OF WORKREQUIRED. DISCONNECT AND REMOVE PNEUMATICCONTROLS ON EXISTING VAV BOX AND ALL ASSOCIATEDPNEUMATIC CONTROL TUBING FROM BOX TOASSOCIATED WALL MOUNTED THERMOSTAT. EXISTINGPNEUMATIC TUBING LOCATED IN WALL SHALL BEABANDONED IN PLACE. PROVIDE A BRASSCOMPRESSION CAP TYPE FITTING AT ALL UNUSEDTERMINATIONS. DO NOT PINCH-OFF TUBING.

B REMOVE EXISTING WALL MOUNTED THERMOSTAT.ABANDON CONTROL TUBING IN WALL. PROVIDE A BRASSCOMPRESSION CAP TYPE FITTING AT ALL UNUSEDTERMINATIONS. DO NOT PINCH-OFF TUBING. PATCHWALL AS REQUIRED TO MATCH EXISTING CONDITIONS.COVER REMAINING HOLE IN WALL WITH BLANKTHERMOPLASTIC SINGLE COVER PLATE. PROVIDEMANUFACTURER'S STANDARD COLOR THAT MOSTCLOSELY MATCHES EXISTING WALL COLOR.

C REMOVE EXISTING DUAL DUCT VAV BOX. DISCONNECTAND REMOVE PNEUMATIC CONTROLS ON EXISTING VAVBOX AND ALL ASSOCIATED PNEUMATIC CONTROL TUBINGFROM BOX TO ASSOCIATED WALL MOUNTEDTHERMOSTAT. EXISTING PNEUMATIC TUBING LOCATEDIN WALL SHALL BE ABANDONED IN PLACE. PROVIDE ABRASS COMPRESSION CAP TYPE FITTING AT ALL UNUSEDTERMINATIONS. DO NOT PINCH-OFF TUBING.

1

1

Page 22: A1/A310 - Contact Us | Campus Facilities | University of ...operations-webapps.missouri.edu/pdc/adsite/projects/cp151661/... · 1/8" = 1'-0" A1/A310 ... SUBSTITUTION REQUEST (During

T T

J K L

8

K.2

CHASE

M763A

68"x9" HOT(TOP)

68"x10" COLD(BELOW)

EAV

7-38

16"x15"

DD

7-20DD

7-21

DD

7-22

DD

7-23

A

A

A

A

1

PROJECT NUMBER:

1900 W. 47th Place

Suite 300

Westwood, Kansas

66205p: 913.362.6500www.pgav.com

Structural Engineers4338 Bellview AvenueKansas City, MO 64111

BOB D. CAMPBELL & CO, INC.

(816) 531-4144

Plumbing and Mechanical Engineers6 South Old OrchardSt Louis, MO 63119

ROSS & BARUZZINI, INC.

(314) 918-8383

Electrical Engineers1600 Genessee St, Suite 260Kansas City, MO 64102

ANTELLA CONSULTING ENGINEERS, INC.

(816) 421-0950

11/19/1553417

Medical Science Renovate 7th Floor West Laboratories

UNIVERSITY OF MISSOURIFOR: The Curators of the University of Missouri No.: CP151661

ADDENDUM 01

XM-09

1/8" = 1'-0"M1/M1027TH FL. DUCTWORK NEW WORK PLAN

ALTERNATE 4 KEYED NOTES:

A NEW DUAL DUCT VAV TERMINAL UNIT. CONNECT TO EXISTINGHOT AND COLD DUCTS AND EXISTING SUPPLY DUCT. SEALDUCTWORK AND INSULATION AIR TIGHT. CONTRACTOR SHALLFIELD VERIFY EXISTING DUCTWORK SIZES AND PROVIDEREQUIRED DUCT TRANSITIONS FOR INSTALLATION UPSTREAMAND DOWNSTREAM OF NEW VAV BOX.

1

Page 23: A1/A310 - Contact Us | Campus Facilities | University of ...operations-webapps.missouri.edu/pdc/adsite/projects/cp151661/... · 1/8" = 1'-0" A1/A310 ... SUBSTITUTION REQUEST (During

F G

6

8

7NEW 6" HWS & HWRUP AND DN

NEW 8" CWS & CWR UPEXISTING 8" CWS & CWR DN

1

PROJECT NUMBER:

1900 W. 47th Place

Suite 300

Westwood, Kansas

66205p: 913.362.6500www.pgav.com

Structural Engineers4338 Bellview AvenueKansas City, MO 64111

BOB D. CAMPBELL & CO, INC.

(816) 531-4144

Plumbing and Mechanical Engineers6 South Old OrchardSt Louis, MO 63119

ROSS & BARUZZINI, INC.

(314) 918-8383

Electrical Engineers1600 Genessee St, Suite 260Kansas City, MO 64102

ANTELLA CONSULTING ENGINEERS, INC.

(816) 421-0950

11/19/1553417

Medical Science Renovate 7th Floor West Laboratories

UNIVERSITY OF MISSOURIFOR: The Curators of the University of Missouri No.: CP151661

ADDENDUM 01

XM-10

1/8" = 1'-0"M1/M1016TH FLOOR NEW WORK PLAN

Page 24: A1/A310 - Contact Us | Campus Facilities | University of ...operations-webapps.missouri.edu/pdc/adsite/projects/cp151661/... · 1/8" = 1'-0" A1/A310 ... SUBSTITUTION REQUEST (During

CFH 03 CFH 04

CF

H 0

2

CF

H 0

1

FH01

CYL

CYLCYL

EQCYL

CYL

CYLCYL

CYLCYL

CYLCYL CYLCYL

T

T

T

T

T

T

T

T

T T

TT

T

T T

T

T

H

H

A B C E F GD H I J K L

1

6

2

3

4

5

8

9

10

11

12

13

14

K.1J.1

7

K.2

1.1

CHASE

M763A

JAN

M763

TOUCHDOWN

M757

SERVICEELEVATOR

-

TISSUE CULTURENW

NW712

FLEX LAB NW

NW710

OFFICE

NW716

OFFICE

NW718

OFFICE

NW720

OFFICE

NW722

SPECIALTY LAB

NW724

MECH ROOM

M750

MICRO

NW701

TOILET

M751

FLEX LAB

M754

STOR

M754B

VEST

M754A

TISSUE CULTURE

M755

LAB SUPPORT

M756

BREAK

M744

TELECOM

M743

OFFICE

NW715

STAIR

MR700

STAIR

MT700

COR

NW714

COR

NW700

COR.

M775A

1

M301

VAV

7-29

VAV

7-22

VAV

7-24

RHC

7-05

2

M3012

DP

D

VAV

7-25

1

M201

RHC 7-05

VAV

7-26

VAV 7-26

VAV 7-25

RHC

7-04

RHC 7-04

VAV 7-24

RHC 7-03

RHC

7-02

RHC

7-01

RHC 7-02

RHC 7-01

VAV

7-23

VAV 7-23

BCU

7-02

BCU 7-02 & VAV 7-22

HWSHWR

CWSCWR

HW

RH

WS

HW

RH

WS

HW

RH

WS

3

M301

4

M301

5

M301

VAV 7-20VAV 7-29

VAV 7-21

VAV

7-21

RHC

7-06

COR

M775

3/4" 3/4"

3/4"3/4"

3/4"

3/4"

1"

1"3/4"3/4"

1" 1"

1 1/4" 1 1/4"

1 1/4" 1 1/4"

3/4"

3/4"

3/4"

3/4"

1"

1"

3/4"

3/4"

1 1/2" 1 1/2"3/4" 3/4"

1 1/2"1 1/2"

3/4" 3/4"

1"1"

1 1/2"1 1/2"

RHC

7-03

3

3/4"

CW

RC

WS

D

RESEARCHLAB

M764

RESEARCHLAB

M772

OFFICE

M771

RESEARCHLAB

M770

OFFICE

M769

OFFICE

M767A

OFFICE

M767

OFFICE

M766

OFFICE

M765

T

T

T

T

T

T

T

T

T

T

T

T

EXISTING STEAMRADIATOR

T

T

T

EX. RELOCATED

EXISTING STEAMRADIATOR

DD

7-20

DD

7-21

DD

7-22

DD

7-23

DD

7-24

DD

7-31

DD

7-25

DD

7-32

DD

7-26DD

7-33

DD

7-27

DD

7-34

DD

7-28DD

7-29

DD

7-35DD

7-30

DD

7-36

A

A

A

A

A

A

A

A

A

A

A

A

B

B

B

B

B

BB

B

B

B

B

B

B

B

B

B B

1

1

1

A

B

C

D

E

6 5 4 3 2 1

1900 w.47th Place, #300, Westwood, KS 66205(913) 362-6500 www.PGAV.COMCopyright ©2015

DRAWN: CHECKED:

DATE:

PGAV # CLIENT #

SHEET #:

0" 1"

Original Size: 1 1/2" Drawing may have been reduced.

PECKHAM GUYTON ALBERS & VIETS, INC.

Electrical Engineers1600 Genessee St, Suite 260Kansas City, MO 64102

ANTELLA CONSULTING ENGINEERS, INC.

Mechanical and Plumbing Engineers6 South Old OrchardSt Louis, MO 63119

ROSS & BARUZZINI, INC.

Structural Engineers4338 Bellview AvenueKansas City, MO 64111

BOB D. CAMPBELL & CO, INC.

(314) 918-8383

(816) 531-4144

(816) 421-0950

NOTE: The architect or engineer sealing this sheettakes responsibility for the drawing that is sealed, andis not responsible for all other sheets in the set.

JEFFREY R. CRAWFORD

MO LICENSE NO. E-27507

11/2

0/20

1 5 9

:15:

20 A

MC

:\Use

rs\s

brue

ning

\Doc

umen

t s\0

1-01

MU

Med

Sci

e nce

_Mec

h_V

15_s

brue

ning

.rvt

M112

11/10/15

53417

SEVENTH FLOORPIPING PLAN

RJD

BID DOCUMENTS

University of Missouri -Columbia

1 Hospital Drive, Columbia, MO65212

RJD JRC

Medical ScienceRenovate 7thFloor West

Laboratories

1/8" = 1'-0"1MECHANICAL SEVENTH FLOOR PIPIING NEW WORK PLAN

NORTH

KEYED NOTES:

2 DIFFERENTIAL PRESSURE TRANSMITTER.

3 10" DIAMETER EXHAUST DUCT UP & DN IN NEW2-HOUR CHASE.

#

0

SCALE:

0

8' - 0"

16' - 0"

24' - 0"1" = 8' - 0"

ALTERNATE 4 KEYEDNOTES:

A A.INSTALL (2) NEW OWNER FURNISHED DDCCONTROLLERS TO EXISTING COOLING AND HEATINGDUAL DUCT VAV BOX. SEE CONTROL DIAGRAMS ONSHEET M704. CALIBRATE AND BALANCE NEWCONTROLLERS TO EXISTING PARAMETERS OF EACHINDIVIDUAL BOX (MAX/MIN CFM BOTH HOT DECK ANDCOLD DECK).

B B.OWNER PROVIDED AND INSTALLED NEW DDCELECTRIC WALL-MOUNTED WIRED THERMOSTAT.EXPOSED CONTROL WIRING IN CONDUIT SHALL BECONCEALED BY WIREMOLD. ALL CONTROL WIRINGTO BE INSTALLED IN FINISHED SPACES SHALL BECONCEALED. WHERE IT IS NOT POSSIBLE TO ROUTEIN EXISTING WALL, PROVIDE WIREMOLD V2000BCTWO-PIECE STEEL SURFACE RACEWAY. WIREMOLDSHALL BE STANDARD PREFINISHED COLOR PICKEDBY ARCHITECT DURING SHOP DRAWING REVIEW.ROUTE WIREMOLD IN A HIGH DISCRETE PATH. PRIORTO INSTALLATION OF WIREMOLD, COORDINATEEXACT ROUTING AND MOUNTING HEIGHT OFWIREMOLD WITH THE OWNER’S REPRESENTATIVE OFA TYPICAL INSTALLATION. DO NOT INSTALLMOUNTED CONDUIT EXPOSED IN FINISHED SPACES.

1

# DATE DESCRIPTION

1 11-19-15 Addendum 1

11/20/15

Page 25: A1/A310 - Contact Us | Campus Facilities | University of ...operations-webapps.missouri.edu/pdc/adsite/projects/cp151661/... · 1/8" = 1'-0" A1/A310 ... SUBSTITUTION REQUEST (During

M

M

M

M

M

T

T

T

GENERATOR

M

M

M

M

M

T

T

T

E F GD

6

5

7

3

M202

16"ø EA

1 1/2"LPR

4"LPS4"LPS3"CWS

3"CWR

48"x11" HOTABOVE

44"x14" RA

EXET

2

24"x

22"

12"x12" OA

24"x22" OA12"x12" OA 14"x10" OA

48"x60" OA

10"x14" OA DN

40"x14" OA DN

1 1/2"LPR

1 1

/2"L

PR

PENTHOUSE

M804

52"x12" EA

26"ø EA

40"x16" OA

80"x

18"

SA

96"x30" SA

EXISTING 12"ø EAUP TO FAN ONPENTHOUSE ROOF

40"x18" OA

48"x12" COLDBELOW

1 1/2"CWR

1 1/2"CWR

1 1

/2"C

WR

12"ø EA DN

12"ø EA

12"ø EA

12"ø

10"x16" EA DN(REMAINS)

EXISTING 10" DIA.GENERATOR EXHAUSTDUCT UP THROUGH ROOF

EXISTING GENERATOROUTSIDE AIR INTAKELOUVER ANDDUCTWORK

EXISTINGGENERATOR

FD

7-13

IN EXISTINGDUCT THROUGHFLOOR

1

1

1

EXISTING AIRHANDLING UNIT

EXISTING AIRHANDLING UNIT

NEW WORK PLAN SHOWINGBASE BID ONLY.

1

E F GD

6

5

7

3

M202

48"x11" DN

48"x12" DN

12"x8" DN 12"x8" DN 10"x14" OA DN

40"x14" OA DN

EXISTING 12"ø EAUP TO FAN ONPENTHOUSEROOF

80"x

18"

SA

40"x16" OA

40"x18" OA

26"ø EA

52"x12" EA

48"x11" HOTABOVE

48"x12" COLDBELOW

EXET

2

44"x14"

44"x14" RA

24"x

22"

OA 12"x12" OA

12"x12" OA

48"x60" OA

24"x22" OA1 1/2"LPR

4"LPS3"CWS

3"CWR

4"LPS

96"x30" SA

1 1/2"CWR

1 1/2"CWR

1 1

/2"C

WR

12"ø

10"x16" EA DN(REMAINS)

DDC PANEL

1

2

3

10" DIA. GENERATOREXHAUST DUCT UPTHROUGH ROOF

GENERATOROUTSIDE AIR INTAKELOUVER ANDDUCTWORK

GENERATOR

4

4

4

EXISTING AIRHANDLING UNIT

EXISTING AIRHANDLING UNIT

1

1

1

ROOF84' - 2 1/2"

F G

T.O. PARAPET89' - 1 5/8"

PENTHOUSE ROOF97' - 6 1/2"

12"ø

80"x18" SA

12"ø EA

10"x16" EA DN(REMAINS)

12"ø

1.

2.

3.

INSULATION IN PIPING AND DUCTWORK MAY CONTAINASBESTOS. SEE ASBESTOS REPORT IN PROJECT MANUAL.CONTRACTOR TO REINSULATE ALL PIPING AND DUCTWORKTHAT SHALL REMAIN TO POINT WHERE INSULATION HASBEEN ABANDONED.

SEE M000 FOR GENERAL NOTES.

CONTRACTOR SHALL COORDINATE WITH ALL DISCIPLINESFOR LOCATION OF EQUIPMENT.

GENERAL NOTES:

A

B

C

D

E

6 5 4 3 2 1

1900 w.47th Place, #300, Westwood, KS 66205(913) 362-6500 www.PGAV.COMCopyright ©2015

DRAWN: CHECKED:

DATE:

PGAV # CLIENT #

SHEET #:

0" 1"

Original Size: 1 1/2" Drawing may have been reduced.

PECKHAM GUYTON ALBERS & VIETS, INC.

Electrical Engineers1600 Genessee St, Suite 260Kansas City, MO 64102

ANTELLA CONSULTING ENGINEERS, INC.

Mechanical and Plumbing Engineers6 South Old OrchardSt Louis, MO 63119

ROSS & BARUZZINI, INC.

Structural Engineers4338 Bellview AvenueKansas City, MO 64111

BOB D. CAMPBELL & CO, INC.

(314) 918-8383

(816) 531-4144

(816) 421-0950

NOTE: The architect or engineer sealing this sheettakes responsibility for the drawing that is sealed, andis not responsible for all other sheets in the set.

JEFFREY R. CRAWFORD

MO LICENSE NO. E-27507

11/2

0/20

1 5 9

:15:

42 A

MC

:\Use

rs\s

brue

ning

\Doc

umen

t s\0

1-01

MU

Med

Sci

e nce

_Mec

h_V

15_s

brue

ning

.rvt

M202

11/10/15

53417

ENLARGEDPENTHOUSE PLANS

RJD

BID DOCUMENTS

University of Missouri -Columbia

1 Hospital Drive, Columbia, MO65212

RJD JRC

Medical ScienceRenovate 7thFloor West

Laboratories

REF: 6 / M201 1/4" = 1'-0"1MECHANICAL PENTHOUSE NEW WORK PLAN

REF: 6 / M201 1/4" = 1'-0"2ALTERNATE 3: MECHANICAL PENTHOUSE DEMOLITION PLAN

REF: 1 / M202 1/4" = 1'-0"3SECTION THROUGH PENTHOUSE

KEYED NOTES:

1 OWNER WILL DISCONNECT AND REMOVE EXISTINGCONTROL PANEL.

2 BASE BID: ALL EXISTING SYSTEMS IN PENTHOUSE SHALLBE ABANDONED IN PLACE. ALTERNATE 3: HATCHED AREAIS ATTEMPT TO ILLUSTRATE AREA OF WORK ASSOCIATEDWITH ALTERNATE #3. UNLESS OTHERWISE NOTED ALLEXISTING EQUIPMENT ASSOCIATED WITH THE TWO (2)EXISTING AIR HANDLING UNITS SERVING THE 7TH FLOORAND EMERGENCY GENERATOR LOCATED IN THISPENTHOUSE SHALL BE TOTALLY DISCONNECTED, DRAINEDAND REMOVED. DEMOLISH ALL ASSOCIATED DUCTWORK,PIPING, INSULATION, HANGERS, SUPPORTS, LOUVERS, ANDEQUIPMENT CURBS. DO NOT LEAVE ANY THINGABANDONED IN PLACE. CAP ALL EXISTING OPENING INWALLS TO MATCH EXISITNG CONDITIONS. INFILL ALLFLOOR OPENINGS WHERE DUCTS AND/OR PIPING AREREMOVED TO MAINTAIN RATING IN FLOOR. CAP ALLEXISTING PIPES THAT ARE SERVING OTHER EXISTINGSYSTEMS THAT ARE STILL ACTIVE. REPLACE AND/ORREPAIR EXISTING INSULTION.

3 10" DIAMETER EXHAUST DUCT UP & DN IN NEW 2-HOURCHASE.

4 BLANK-OFF LOUVER AS PART OF ALTERNATE #3.

#

1

1

# DATE DESCRIPTION

1 11-19-15 Addendum 1

11/20/15