2
INSTALL IN TRANSMISSION PRESSURE PORT SEE STEP PTO Shift Codes: HX, JX 2 TO TRANSMISSION PRESSURE PORT TORQUE TO 10–13 FT .LBS . PRESSURE SWITCH TORQUE TO 10–12 FT .LBS . PTO REAR COVER ROTATABLE TORQUE TO 18 FT.LBS . (3 PLCS) B A 1 For Integral Solenoid Activation 360 HARNESS CONNECTION HARNESS CONNECTION ON SIDE PTO REAR COVER ROTATABLE B PORT 2 PORT 3 PRESSURE SWITCH PORT 4 360 360 HARNESS CONNECTION HARNESS CONNECTION INSTALL IN TRANSMISSION PRESSURE PORT SEE STEP 2 TO TRANSMISSION PRESSURE PORT PTO Shift Codes: HR, JR A SOLENOID VALVE ROTATABLE PORT 1 PORT 4 LUBE CLUTCH EXHAUST TORQUE TO 18 FT.LBS. (3 PLCS) TORQUE TO 10–12 FT.LBS. TORQUE TO 3 FT.LBS. (2 PLCS) TORQUE ALL FITTINGS TO 10–13 FT.LBS. Port Right Side Port Left Side Port Main Pressure Port “P” 7/16-20 UNF 2A (SAE -4) 180–320 PSI Main Pressure Port “P” 7/16-20 UNF 2A (SAE -4) 180–320 PSI Main Pressure Port “P” 7/16-20 UNF 2A (SAE -4) 180–298 PSI 3000 SERIES 4000 SERIES Transmission Pressure Port Locations 2 Left Side A B RED BLUE GREEN BLACK BLUE RED BLACK GREEN BATTERY + 10A FUSE TO ALLISON TCM CONNECTION FOR PTO ENABLE INPUT** Solenoid Valve TO BATTERY GROUND 3 Wiring Harness Installation INDICATOR LIGHT Light is to be “ON” when unit is engaged and “OFF” when unit is disengaged. Mount the activation switch in clear view of the operator. Indicator light must be installed in clear view of operator while seated in vehicle’s driver seat. Use 36MK1210-A if additional warning light is needed. *Do not install other electrical components or devices to the Muncie pressure switch. This switch is to be used for the indicator light only. ** Clutch shift PTO requires connection to Allison “PTO Enable Input” Circuit on Allison Gen. 4 and later controls. Contact Muncie Power or Allison for more details. Check with vehicle dealer or body builder’s information for location. Make connections to A and B from Step 1 Pressure Switch * A20 10-BOLT CLUTCH SHIFT PTO ACTIVATION Allison 3000/4000 Series Transmissions 201 East Jackson Street, Muncie, Indiana 47305 800-367-7867 Fax: 765-284-6991 [email protected] Specifications are subject to change without notice. Visit www.munciepower.com for warranties and literature. All rights reserved. © Muncie Power Products, Inc. (2021) IN21-02 (Rev. 03-22) A Member of the Interpump Group

A20 10-BOLT CLUTCH SHIFT PTO ACTIVATION 2 Transmission 3

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: A20 10-BOLT CLUTCH SHIFT PTO ACTIVATION 2 Transmission 3

INSTALL IN TRANSMISSION PRESSURE PORTSEE STEP

PTO Shift Codes: HX, JX

2TO TRANSMISSION PRESSURE PORT

TORQUE TO10–13 FT.LBS .

PRESSURE SWITCH TORQUE TO 10–12 FT.LBS .

PTO REAR COVER ROTATABLE TORQUE TO 18 FT.LBS . (3 PLCS)

BA

1 For Integral Solenoid Activation

360

HARNESS CONNECTION

HARNESS CONNECTION

ON SIDE

PTO REAR COVER ROTATABLE

B

PORT 2PORT 3

PRESSURE SWITCH PORT 4

360

360

HARNESS CONNECTION

HARNESS CONNECTION INSTALL IN

TRANSMISSION PRESSURE PORTSEE STEP 2

TO TRANSMISSION PRESSURE PORT PTO Shift Codes: HR, JR

ASOLENOID VALVE ROTATABLE

PORT 1

PORT 4LUBE

CLUTCH

EXHAUST

TORQUE TO 18 FT.LBS. (3 PLCS)TORQUE TO 10–12 FT.LBS.

TORQUE TO 3 FT.LBS. (2 PLCS)

TORQUE ALL FITTINGS TO 10–13 FT.LBS.

Port

Right Side

Port

Left Side

Port

Main Pressure Port “P”7/16-20 UNF 2A (SAE -4)180–320 PSI

Main Pressure Port “P”7/16-20 UNF 2A (SAE -4)180–320 PSI

Main Pressure Port “P”7/16-20 UNF 2A (SAE -4)180–298 PSI

3000 SERIES

4000 SERIES

Transmission Pressure Port

Locations2

Left Side

A B

RED

BLUEGREEN

BLACK

BLUE

RED

BLACK

GREEN

BATTERY

+10A

FUSE

TO ALLISON TCM CONNECTIONFOR PTO ENABLE INPUT**

Solenoid Valve

TOBATTERYGROUND

3 Wiring Harness Installation

INDICATOR LIGHT

Light is to be “ON” when unit is engaged and “OFF” when unit is disengaged. Mount the activation switch in clear view of the operator. Indicator light must be installed in clear view of operator while seated in vehicle’s driver seat. Use 36MK1210-A if additional warning light is needed.

*Do not install other electrical components or devices to the Muncie pressure switch. This switch is to be used for the indicator light only.

** Clutch shift PTO requires connection to Allison “PTO Enable Input” Circuit on Allison Gen. 4 and later controls. Contact Muncie Power or Allison for more details. Check with vehicle dealer or body builder’s information for location.

Make connections to A and B from Step 1

Pressure Switch*

A20 10-BOLT CLUTCH SHIFT PTO ACTIVATIONAllison 3000/4000 Series Transmissions

201 East Jackson Street, Muncie, Indiana 47305800-367-7867 • Fax: 765-284-6991 • [email protected]

Specifications are subject to change without notice. Visit www.munciepower.com for warranties and literature. All rights reserved. © Muncie Power Products, Inc. (2021)

IN21-02 (Rev. 03-22)

A Member of the Interpump Group

Page 2: A20 10-BOLT CLUTCH SHIFT PTO ACTIVATION 2 Transmission 3

Oficinas generales y centro de distribución • 201 East Jackson Street • Muncie, Indiana 47305800-367-7867 • Fax 765-284-6991 • [email protected]

Las especificaciones están sujetas a cambios sin previo aviso. Visita www.munciepower.com para las garantías y la literatura. Todos los derechos reservados. © Muncie Power Products, Inc. (2021)

Puerto

Lado derecho

Puerto

Lado izquierdo

Puerto

Puerto de presión principal “P”7/16-20 UNF 2A (SAE -4)180–320 PSI

Puerto de presión principal “P” 7/16-20

180–320 PSI

Puerto de presión

UNF 2A (SAE -4)180–298 PSI

SERIE 3000

SERIE 4000

Ubicaciones delpuerto de presiónde transmisión 2

Lado izquierdo

principal “P” 7/16-20

UNF 2A (SAE -4)

AB

ROJO

AZULVERDE

NEGRO

AZUL

ROJO

NEGRO

VERDE

BATERÍA +FUSIBLE

10A

A LA CONEXIÓN TCM(MÓDULO DE CONTROLDE TRANSMISIÓN) DE ALLISONPARA LA ENTRADA DEACTIVACIÓN DE LA TDF**

Válvula solenoide

A LA MASADE LA BATERÍA

3Instalación del arnés de cableado

LUZ INDICADORA

Haga conexiones a A y B desde el Paso 1

Interruptor de presión*

La luz debe estar en “ON” (ENCENDIDA) cuando la unidad estéactivada y en “OFF” (APAGADA) cuando la unidad esté desactivada.Monte el interruptor de activación a la vista del operador. La luz indicadora se debe instalar a la vista del operador mientras este se encuentre en el asiento del conduc-tor del vehículo. Use 36MK1210-A en caso de que se necesite una luz de adverten-cia adicional.

*No instale otros componentes o dispositivos eléctricos en el interruptor de presiónde Muncie. Este interruptor se debe utilizar solamente para la luz indicadora.** La TDF con cambio accionado por embrague requiere conexión al Circuito “PTO Enable Input” (Entrada de activación de la TDF) de Allison en controles Allison de 4ta generación y superiores. Póngase en contacto con Muncie Power o Allison para obtener más detalles. Verifique con el distribuidor del vehículo o la información de fabricantes de carrocerías para obtener la ubicación.

ACTIVACIÓN DE LA TDF DE 10 PERNOS CON CAMBIO POR ACCIONAMIENTO DE EMBRAGUE A20 Transmisiones serie Allison 3000/4000

CUBIERTA POSTERIORORIENTABLE DE LA TDF

B

PUERTO 2PUERTO 3

INTERRUPTOR DE PRESIÓN PUERTO 4

360

360

CONEXIÓNDEL CABLEADO

CONEXIÓNDEL CABLEADOINSTALAR EN

EL PUERTO DEPRESIÓN DE LATRANSMISIÓNVER EL PASO 2

AL PUERTO DE PRESIÓNDE LA TRANSMISIÓN Códigos de cambio de la TDF: HR, JR

Para activación de solenoide remoto

AVÁLVULA SOLENOIDE ORIENTABLE

PUERTO 1

PUERTO 4LUBRICACIÓN

EMBRAGUE

ESCAPE

APLICAR TORSIÓN A 18 PIES-LBS.(3 LUGARES)

APLICAR A TODOS LOS ACCESORIOSUNA TORSIÓN DE 10–13 PIES-LBS.

APLICAR TORSIÓNA 10–12 PIES-LBS.

APLICAR TORSIÓN A 3 PIES-LBS.(2 LUGARES)

2

INTERRUPTOR DE PRESIÓNAPLICAR TORSIÓNA 10–12 PIES-LBS.

CUBIERTA POSTERIOR ORIENTABLE DE LA TDFAPLICAR TORSIÓN A 18 PIES-LBS. (3 LUGARES)

B A

1

360

INSTALAR EN ELPUERTO DE PRESIÓNDE LA TRANSMISIÓNVER EL PASO

AL PUERTO DE PRESIÓN DE LA TRANSMISIÓN

APLICAR TORSIÓNA 10–13 PIES-LBS.

CONEXIÓNDEL CABLEADOEN EL LATERAL

Para activación de solenoide integralCódigos de cambio de la TDF: HX, JX

CONEXIÓNDEL CABLEADO

IN21-02 (Rev. 03-22)

A Member of the Interpump Group