AAT Injector Nozzle Test Chamber P15681 Calibration Fluid Exhaust System ach Huston, Hayden Cummings, Adam Farnung, Tim Nichols, Robert Moshier, Andrew Heuser

AAT Injector Nozzle Test Chamber P15681 Calibration Fluid Exhaust System Zach Huston, Hayden Cummings, Adam Farnung, Tim Nichols, Robert Moshier, Andrew

Embed Size (px)

Citation preview

Page 1: AAT Injector Nozzle Test Chamber P15681 Calibration Fluid Exhaust System Zach Huston, Hayden Cummings, Adam Farnung, Tim Nichols, Robert Moshier, Andrew

AAT Injector Nozzle Test Chamber

P15681 Calibration Fluid Exhaust System

Zach Huston, Hayden Cummings, Adam Farnung, Tim Nichols, Robert Moshier, Andrew Heuser

Page 2: AAT Injector Nozzle Test Chamber P15681 Calibration Fluid Exhaust System Zach Huston, Hayden Cummings, Adam Farnung, Tim Nichols, Robert Moshier, Andrew

AgendaProject Background

Updated Requirements

Chamber design

Measurement System

Action Items

Fluid removal system

Page 3: AAT Injector Nozzle Test Chamber P15681 Calibration Fluid Exhaust System Zach Huston, Hayden Cummings, Adam Farnung, Tim Nichols, Robert Moshier, Andrew

Background - AATAdvanced Atomization Technologies (AAT)• Joint venture between General Electric Aviation and

Parker Aerospace

• Specializes in manufacturing and testing fuel nozzles for gas turbine engines

Page 4: AAT Injector Nozzle Test Chamber P15681 Calibration Fluid Exhaust System Zach Huston, Hayden Cummings, Adam Farnung, Tim Nichols, Robert Moshier, Andrew

Background - ProjectFuel Injection Nozzle Testing System• Qualifying fuel injection nozzles• Specialized calibration equipment• Expensive, odorous calibration fluidProblems with system• Offensive odor permeates entire building• Loss of expensive calibration fluid

Page 5: AAT Injector Nozzle Test Chamber P15681 Calibration Fluid Exhaust System Zach Huston, Hayden Cummings, Adam Farnung, Tim Nichols, Robert Moshier, Andrew

Problem Definition• All commercial aircraft nozzles must undergo a flow test to

assure that requirements are met for spray angle.• This test uses Stoddart Solvent (MIL-PRF-7024F Type II)• Petroleum derived, clear, transparent liquid.• The fluid is very expensive and has an offensive odor• The current exhaust system is ineffective at both containing

containing the odor and recovering the atomized fluid for reuse.

Page 6: AAT Injector Nozzle Test Chamber P15681 Calibration Fluid Exhaust System Zach Huston, Hayden Cummings, Adam Farnung, Tim Nichols, Robert Moshier, Andrew

Project Schedule

Represents Critical items

Page 7: AAT Injector Nozzle Test Chamber P15681 Calibration Fluid Exhaust System Zach Huston, Hayden Cummings, Adam Farnung, Tim Nichols, Robert Moshier, Andrew

Customer Requirements

Page 8: AAT Injector Nozzle Test Chamber P15681 Calibration Fluid Exhaust System Zach Huston, Hayden Cummings, Adam Farnung, Tim Nichols, Robert Moshier, Andrew

Engineering Requirements

Page 9: AAT Injector Nozzle Test Chamber P15681 Calibration Fluid Exhaust System Zach Huston, Hayden Cummings, Adam Farnung, Tim Nichols, Robert Moshier, Andrew

Verification of Engr. Req.

Page 10: AAT Injector Nozzle Test Chamber P15681 Calibration Fluid Exhaust System Zach Huston, Hayden Cummings, Adam Farnung, Tim Nichols, Robert Moshier, Andrew

Chamber DesignComponents: - Containment Chamber (Collection and containment of liquid cal

fluid)- Airlock (Test location, isolation, purge)- Nozzle Fixture (Integration of both tests in one location, constrain

and attach nozzle)- Gloves (Correct Material, ergonomics, attachment)

Page 11: AAT Injector Nozzle Test Chamber P15681 Calibration Fluid Exhaust System Zach Huston, Hayden Cummings, Adam Farnung, Tim Nichols, Robert Moshier, Andrew

Full model

Page 12: AAT Injector Nozzle Test Chamber P15681 Calibration Fluid Exhaust System Zach Huston, Hayden Cummings, Adam Farnung, Tim Nichols, Robert Moshier, Andrew

Ergonomic AnalysisSystem must accommodate operator heights from 62” – 76”

Shoulder width range: 16.1” – 17.7”•Center to center glove separation 14”

Range of distance from shoulder to ground:50.7” – 62.17”

•Chamber will require 1 foot of adjustable vertical travel

*For details on the anthropometric analysis reference System Level Design Documents on EDGE

Page 13: AAT Injector Nozzle Test Chamber P15681 Calibration Fluid Exhaust System Zach Huston, Hayden Cummings, Adam Farnung, Tim Nichols, Robert Moshier, Andrew

Ergonomic Analysis

46”

62”

To accommodate all operators and be safe to operate from the top and in the gloves the chamber requires 16” of travel

Page 14: AAT Injector Nozzle Test Chamber P15681 Calibration Fluid Exhaust System Zach Huston, Hayden Cummings, Adam Farnung, Tim Nichols, Robert Moshier, Andrew

Nozzle fixtureOverview:- Combines flow and angle testing in one location- Incorporates both nozzle block-offs for flow testing and

measurement system for angle testingRoles in Engineering Requirements:- S4: “Elapsed Time”: does not add significant cycle time

Page 15: AAT Injector Nozzle Test Chamber P15681 Calibration Fluid Exhaust System Zach Huston, Hayden Cummings, Adam Farnung, Tim Nichols, Robert Moshier, Andrew

Upper DoorOverview:- Provides access to the nozzle fixture inside of the airlock- O-Ring sealed, solenoid locked (to be integrated into controls system)Roles in Engineering Requirements:- S1: “Air Quality”: Contains Calibration Fluid- S2: “Air Particle Removal”: Provides Seal for Vacuum- S8: “Calibration Fluid Leak”: Contains Calibration Fluid- S9: “Door Sealed During Operation” - S11: “Accessibility”: Easy Access for operator to Test Block

Page 16: AAT Injector Nozzle Test Chamber P15681 Calibration Fluid Exhaust System Zach Huston, Hayden Cummings, Adam Farnung, Tim Nichols, Robert Moshier, Andrew

GlovesOverview:- ‘Blast Chamber’ Style gloves- Allow operator access without exposure to fluidRoles in Engineering Requirements:- S1: “Air Quality”: Fluid does not leave chamber during operator interaction- S8: “Calibration Fluid Leak”: Calibration Fluid does not escape during

operator interaction- S11: “Accessibility”: Easy Access for operator to Dual Block-off

Page 17: AAT Injector Nozzle Test Chamber P15681 Calibration Fluid Exhaust System Zach Huston, Hayden Cummings, Adam Farnung, Tim Nichols, Robert Moshier, Andrew

Mid Chamber ValvesOverview:- Ball valve interface between top and bottom chamber- Allows for separation of Air Lock from collected calibration fluid and smaller

evacuation chamberRoles in Engineering Requirements:- S1: “Air Quality”: Liquid Cal fluid is isolated to completely closed portion of

chamber- S3: “Liquid Drain Rate”: Easy Access for operator to Dual Block-off

Page 18: AAT Injector Nozzle Test Chamber P15681 Calibration Fluid Exhaust System Zach Huston, Hayden Cummings, Adam Farnung, Tim Nichols, Robert Moshier, Andrew

Chamber Design Testing- Glove Pressure Testing: Several gloves samples were subjected

to an air pressure of approximately 14.7 psi to test their structural stability to maximum internal chamber pressure. (Please see: subsystem testing, glove pressure test videos for more information)

- Glove Material Exposure Testing: Samples of the same glove materials were exposed to the calibration fluid for two spans of time. Tests were performed on the samples post-exposure to record data for effects of the fluid on the materials. (Please see: subsystem testing, “Test Procedure Sheet (glove test).docx” for more information)

Page 19: AAT Injector Nozzle Test Chamber P15681 Calibration Fluid Exhaust System Zach Huston, Hayden Cummings, Adam Farnung, Tim Nichols, Robert Moshier, Andrew

Bottom ChamberOverview:- Provides space for liquid calibration fluid to collect, separate from the air

lock- Drain in bottom for line to fluid collection tank, recycled back into systemRoles in Engineering Requirements:- S1: “Air Quality”: Liquid Cal fluid is isolated to completely closed portion of

chamber- S3: “Liquid Drain Rate ”: Easy Access for operator to Dual Block-off- S8: “Calibration Fluid Leak”: Liquid Calibration Fluid is kept separate from

rest of chamber, away from main openeing

Page 20: AAT Injector Nozzle Test Chamber P15681 Calibration Fluid Exhaust System Zach Huston, Hayden Cummings, Adam Farnung, Tim Nichols, Robert Moshier, Andrew

Measurement

Page 21: AAT Injector Nozzle Test Chamber P15681 Calibration Fluid Exhaust System Zach Huston, Hayden Cummings, Adam Farnung, Tim Nichols, Robert Moshier, Andrew
Page 22: AAT Injector Nozzle Test Chamber P15681 Calibration Fluid Exhaust System Zach Huston, Hayden Cummings, Adam Farnung, Tim Nichols, Robert Moshier, Andrew

Fluids Subsystem

• Mist evacuation is needed to maintain visibility during test.

• The amount of air pulled from the system must be adjustable .

• Evacuating mist cannot influence the testing procedure.

• A two speed system combines low speed for visibility during test with high speed for fast mist evacuation at the end of the test.

Page 23: AAT Injector Nozzle Test Chamber P15681 Calibration Fluid Exhaust System Zach Huston, Hayden Cummings, Adam Farnung, Tim Nichols, Robert Moshier, Andrew

Subsystem Flow

• By keeping the entire system sealed, no calibration fluid is allowed to escape.

• All aspects of the system are sealed including chamber doors, chamber drain, drain tank, mist collector system and mist collector drain.

• The test chamber will be automatically purged before allowing the chamber doors to be opened, eliminating the chance for an operator to come in contact with the atomized while also not allowing the atomized fluid to escape.

• Fluid that is pulled through the mist collector is returned to the drain tank.

• System is automated to reduce operator error.

Page 24: AAT Injector Nozzle Test Chamber P15681 Calibration Fluid Exhaust System Zach Huston, Hayden Cummings, Adam Farnung, Tim Nichols, Robert Moshier, Andrew

Fluids Subsystem - Heart

• The heart of the subsystem is the AER Control System CM300.

• This unit is able to pull 300 cfm from the test chamber to quickly purge the system, while being throttled back during testing in order to not effect test results.

• Custom built unit will feature aluminum rotating drum to eliminate spark risk.

• Unit will be fitted with an activated carbon after filter to reduce any remaining odor.

• Filter can be replaced with ordinary activated carbon which is inexpensive and easily procured.

• Fluid removed via the collector will be returned to the drain tank.

Page 25: AAT Injector Nozzle Test Chamber P15681 Calibration Fluid Exhaust System Zach Huston, Hayden Cummings, Adam Farnung, Tim Nichols, Robert Moshier, Andrew

Controls/ Integration

Page 26: AAT Injector Nozzle Test Chamber P15681 Calibration Fluid Exhaust System Zach Huston, Hayden Cummings, Adam Farnung, Tim Nichols, Robert Moshier, Andrew

Risk Assessment

Page 27: AAT Injector Nozzle Test Chamber P15681 Calibration Fluid Exhaust System Zach Huston, Hayden Cummings, Adam Farnung, Tim Nichols, Robert Moshier, Andrew

Remaining Risks Risk Importance Plan for Mitigation Completion

Date

Air / Fluid Leaks (27)(9) Test plan available on Edge under “Subsystem Test plans” ‘Test for Air Leaks in Chamber’

MSD II (Week 3-5)

Nozzle Detaches 27 Run test with different fittings to see which forms the best connection and is the easiest to install

Week 14

Inability to interact with control system

9 Determine I/O capabilities of test pressure control system

Week15

Subsystem integration fail

27 Continue weekly updates Ongoing

Page 28: AAT Injector Nozzle Test Chamber P15681 Calibration Fluid Exhaust System Zach Huston, Hayden Cummings, Adam Farnung, Tim Nichols, Robert Moshier, Andrew

Bill of Materials

Page 29: AAT Injector Nozzle Test Chamber P15681 Calibration Fluid Exhaust System Zach Huston, Hayden Cummings, Adam Farnung, Tim Nichols, Robert Moshier, Andrew

Action Items• Design Signed off by Jim• Complete drawing package• Make appointment with operators to perform

glove simulation• Compile purchase orders