Upload
others
View
11
Download
0
Embed Size (px)
Citation preview
ABSOLUTE EVENT SOLUTIONSCEILING HEIGHTS & ELEVATOR MEASUREMENTS| CENTER415
Page 2: 1st Floor | 5th AvenuePage 3: First Floor | 38th StreetPage 4: First Floor | 37th StreetPage 5: Second Floor Lobby | Bathroom AreaPage 6: Second Floor | 37th StreetPage 7: Exhibition Hall North | Entry Room 1 & 2Page 8: Second Floor | 38th StreetPage 9: 37th Street ElevatorPage 10: Lobby/38th Street ElevatorPage 11: 38th Street Freight ElevatorPage 12: 38th Street Freight Elevator Door
Please note these measurements are meant as general guidelines. Client is responsible for taking their own measurements.
Contact:John Reilly
Director of Operations646-398-9100 ext 3
ABSOLUTE EVENT SOLUTIONSCEILING HEIGHTS | CENTER415
Ground Floor Lobby Entrance15'7"
Ground Floor Lobby14'5"
1st Floor | 5th Avenue
Please note these measurements are meant as general guidelines. Client is responsible for taking their own measurements.
2
North ExhibitCeiling: 18'4" Beam: 17'3"
AC: 12' 6"
Beam
Ceiling
AC
Bathroom Area7'11”
Back of House7'9"
First Floor | 38th Street
ABSOLUTE EVENT SOLUTIONSCEILING HEIGHTS | CENTER415
Please note these measurements are meant as general guidelines. Client is responsible for taking their own measurements.
3
South ExhibitCeiling: 18'5"Beam - 17'4"
HVAC - 15'
First Floor | 37th Street
Beam Ceiling
AC
ABSOLUTE EVENT SOLUTIONSCEILING HEIGHTS | CENTER415
Please note these measurements are meant as general guidelines. Client is responsible for taking their own measurements.
4
ABSOLUTE EVENT SOLUTIONSCEILING HEIGHTS | CENTER415
Second Floor Lobby10’5”
Second Floor | Bathroom Area10’5”
Please note these measurements are meant as general guidelines. Client is responsible for taking their own measurements.
5
Ceiling
AC
ABSOLUTE EVENT SOLUTIONSCEILING HEIGHTS | CENTER415
Beam Ceiling
AC
Exhibition Hall SouthCeiling - 14'9"Beam - 13'8"HVAC - 12'3"
Second Floor | 37th Street
Please note these measurements are meant as general guidelines. Client is responsible for taking their own measurements.
6
ABSOLUTE EVENT SOLUTIONSCEILING HEIGHTS | CENTER415
Exhibition Hall North | Entry Room 110’11”
Exhibition Hall North | Entry Room 210’11”
Please note these measurements are meant as general guidelines. Client is responsible for taking their own measurements.
7
ABSOLUTE EVENT SOLUTIONSCEILING HEIGHTS | CENTER415
Exhibition Hall NorthCeiling -14'9"Beam - 13'7"HVAC - 12'5"
Second Floor | 38th Street
Beam Ceiling
AC
Please note these measurements are meant as general guidelines. Client is responsible for taking their own measurements.
8
ABSOLUTE EVENT SOLUTIONSELEVATOR MEASUREMENTS | CENTER415
Door: 2'11“ x 7’Width: 5'8"Depth: 4'2"
Height: 7'10"
37th Street Elevator
2’11”
7'10"
5'8"
4'2"
7’
Please note these measurements are meant as general guidelines. Client is responsible for taking their own measurements.
9
ABSOLUTE EVENT SOLUTIONSELEVATOR MEASUREMENTS| CENTER415
Lobby/38th Street Elevator
Doors: 3'11“ W x 7’ HDepth: 5'4"Width: 8'6"Height: 7'9"
3'11“
7’ 7'9"
8'6"
Please note these measurements are meant as general guidelines. Client is responsible for taking their own measurements.
10
Ce
ilin
g: 8
’3”
Width: 6’10”
ABSOLUTE EVENT SOLUTIONSELEVATOR MEASUREMENTS| CENTER415
38th Street Freight Elevator
Please note these measurements are meant as general guidelines. Client is responsible for taking their own measurements.
Height Width, Depth, Diagonal
11
Door Width: 4’10”
Door Height: 6’ 5”
ABSOLUTE EVENT SOLUTIONSELEVATOR MEASUREMENTS| CENTER415
38th Street Freight Elevator Door
Please note these measurements are meant as general guidelines. Client is responsible for taking their own measurements.
12