    CONTENTS

    1. ACE III Design & Structure

    2. ACE III Room Thermostat

    3. ACE III Features & Strong Points

    4. Comparison of GOM+ & ACE III

    5. ACE III Sales Points

  • 8/7/2019 ACE III-gas heater

    3/12

    31. ACE III Design & Structure

    ACE III Design ACE III Inner Structure

    Tap water Inlet(include Sediment Filter)Heating Return

    Heating Supply

    D.H.W. Outlet

    Gas Inlet

    Pressure Relief V/V

    Modulating Gas Control V/V

    Air Inlet Flue Exhaust

    Expansion Tank

    Heating Air Vent

    Flow S/W

    3-Way V/V

    Circulation Pump(Canned Type)

    Pressure Gauge

    Domestic Heat Exchanger

    Fan Assembly

    Burner Assembly

    Main Heat Exchanger (STS)

    Combustion Chamber

    Heating Strainer

    APS (Air Pressure Sensor)

    Controller, PCB

    Domestic Water Flow S/W

  • 8/7/2019 ACE III-gas heater

    4/12

    42. ACE III Room Thermostat

    Quick D.H.W Power

    D.H.W Only

    A/S Running

    D.H.W Heating

    HML

    WRT

    Select a Heating

    Control Type

    Water Temp. / Room Temp.

    / Timer

    Heating Control

    Quick D.H.W Function

    Automatically be released

    after 10 minutes if not using

    Quick D.H.W

    W : 40~80C / R : 10~40C / T : 0~12HH : 70C / M : 60C / L : 50C

  • 8/7/2019 ACE III-gas heater

    5/12

    53. ACE III Features & Strong Points (1)

    Stainless Steel Heat Exchanger

    - Durable and Clean- Possible to run a mid-water temp.

    (30~50) operation without any

    corrosion.- Long Life and High Efficiency

    SMPS (Switching Mode Power Supply) into Main PCB

    - Stabilize the power supply- Protect all the electric components of a boiler- Extend life time of a boiler & the components- Be able to allow a wider voltage range => 220V30%

    Mid-Water Temperature Operation

    Mid-water temperature (30~50) heating give a lower heat loss in the distribution system,

    lower standby losses of the boiler, and a higher efficiency. (especially better result under well isolatedheating circumstance) But there will be condensing water and corrosion on the heat exchanger.

  • 8/7/2019 ACE III-gas heater

    6/12

    63. ACE III Features & Strong Points (2)

    - Adopt a high precision Canned Type Pump.- Effectively reduce a noise level.- Prevent a noise problem due to any attracting iron substance to

    the impeller of a pump (especially Magnetic Type Pump).

    Canned Type Circulation Pump

    - Pre-heat the cold water in the piping. (Quick D.H.W button)- Possible to get the hot water as soon as the tap is up.- No need to waste water until all the cold water in the piping is drained out.- To save the gas, this function is released after 10 minutes if not using D.H.W.

    Pre-heated hot water delivery system

  • 8/7/2019 ACE III-gas heater

    7/12

    7

    APS (Air Pressure Sensor)

    - Sense the level of magnetic moving accordingto the difference of pressure (P) between

    (+) and (-).- Give a signal to the main controller to indicatehow much air is being supplied exactly.

    - Possible to operate a boiler safely eventhere is any sudden change of external impact(e.g. Contrary or Strong wind).

    - Flexibility of flue installation(e.g. Length and structure of flue installation)

    3. ACE III Features & Strong Points (3)

    (-)

    (+)

    Air Pressure SensorMain

    PCBVenturi

    Air

    FanMagnetic

    Pole

    Hall-IC

  • 8/7/2019 ACE III-gas heater

    8/12

    8

    APS (Air Pressure Sensor)

    - In the real case, the wind is very changeable.- As you can see the test graph below, (A) case emits much CO if the wind

    intermittently blows.- But in the (B) case (APS), volume of CO is very low and give a stable combustion

    even under any changeable wind condition.

    3. ACE III Features & Strong Points (4)

    4.710.55.010.54.810.410.0O2 (%)

    330092280090320098138CO (ppm)

    0400400400Velocity(m/s)

    1412108642Time (min)

    (A) By Velocity of Rotational Frequency (B) By APS (Air Pressure Sensor)

    0400400400Velocity(m/s)

    11.010.811.210.610.910.811.0O2 (%)

    36403250353836CO (ppm)

    1412108642Time (min)

    * Tested by Navien laboratory

    Time (min.) Time (min.)

  • 8/7/2019 ACE III-gas heater

    9/12

    9

    Anti-Freezing System

    - Start a circulation pump and circulate water in the heating pipingif the temp. of heating water below 10.

    - Start a boiler if the temp. of heating water below 6 to prevent freezing.

    - No need any additional electric heater thanks to inner pipings are shortand D.H.W part can be heated indirectly.

    3. ACE III Features & Strong Points (5)

    Ratio Control

    - Control flame- After reaching the setting temp.,

    reduce the flame.

    - Effectively reduce gas consumptionCompared to a On / Off Control

    Time

    Time

    GasCo

    nsumption

    GasConsumption

    Ratio Control

    On / Off Control

  • 8/7/2019 ACE III-gas heater

    10/12

    10

    Adaptive Heating Control

    3. ACE III Features & Strong Points (6)

    - Learn and adapt the specific heatingcircumstance.

    - Supply the most suitable heatingaccording to the each condition.(e.g. isolation level of the house,change of the temperature outdoor)

    Motorized Cam Shift Type 3-Way Valve

    - No wear & durable- Better sealed compared to a rotatingball type 3-way valve

    - Naviens own patent technology

    On/Off Control

    Adaptive Control

    RoomTemp.

    Time

  • 8/7/2019 ACE III-gas heater

    11/12

    114. Comparison of GOM+ & ACE III

    STSCuH/E

    0.1bar0.2barWATER PRESSURE

    50~250mmH2O100~250mmH2OGAS PRESSURE-40-20COLD RESISTANCE

    220V30%220V20%VOLTAGE

    83%82%~83%EFFICIENCY (GCV)

    Canned TypeMagnetic TypePUMP TYPE

    SLIMED AND

    STANDARDIZED

    440*265*695485*235*630

    (525*250*685)

    SIZE

    (W*D*H)

    ELECTRIC AIR RATIOCURRENT RATIOCONTROL TYPE

    DESIGN

    REMARKACE IIIGOM+

    * GCV : Gross Calorific Value / H/E : Heat Exchanger

  • 8/7/2019 ACE III-gas heater

    12/12

    ACE IIIACE III

    Canned TypePumpCanned Type

    Pump

    A/S PartsControl

    A/S PartsControl

    WiderWater Pressure

    Allowance

    WiderWater Pressure

    Allowance

    ColdResistance

    ColdResistance

    125. ACE III Sales Points

    WiderGas Pressure

    AllowanceWider

    Gas PressureAllowance

    WaterFilterWaterFilter