8
SINT Technology s.r.l. Tel: +39.055.8826302 · Fax: +39.055.8826303 · [email protected] · www.sintechnology.com Acoustic Sound Level and Sound Intensity Measurements

Acoustic - sintechnology.com · EN ISO 11200 EN ISO 11201 EN ISO 11202 EN ISO 11203 EN ISO 11204 Macchine industriali Sorgenti di rumore Determination of sound power levels of noise

  • Upload
    others

  • View
    120

  • Download
    1

Embed Size (px)

Citation preview

Page 1: Acoustic - sintechnology.com · EN ISO 11200 EN ISO 11201 EN ISO 11202 EN ISO 11203 EN ISO 11204 Macchine industriali Sorgenti di rumore Determination of sound power levels of noise

SINT Technology s.r.l. Tel: +39.055.8826302 · Fax: +39.055.8826303 · [email protected] · www.sintechnology.com

Acoustic

Sound Level and Sound Intensity Measurements

Page 2: Acoustic - sintechnology.com · EN ISO 11200 EN ISO 11201 EN ISO 11202 EN ISO 11203 EN ISO 11204 Macchine industriali Sorgenti di rumore Determination of sound power levels of noise

SINT Technology s.r.l. Tel: +39.055.8826302 · Fax: +39.055.8826303 · [email protected] · www.sintechnology.com

Page 3: Acoustic - sintechnology.com · EN ISO 11200 EN ISO 11201 EN ISO 11202 EN ISO 11203 EN ISO 11204 Macchine industriali Sorgenti di rumore Determination of sound power levels of noise

SINT Technology s.r.l. Tel: +39.055.8826302 · Fax: +39.055.8826303 · [email protected] · www.sintechnology.com

Determination of sound power levels of noise sources using sound

pressure and sound intensity method

Noise is a critical parameter for health and safety and noise exposure must be kept under control.

Noise is characteristic of the environment in which we live and is chiefly determined by the presence of man.

Whether in a natural environment, a civil or industrial installation, noise requires the intervention of man for it to

be kept under control and to limit the impact of noise on daily activities.

Acoustic Sound Level and Sound Intensity Measurements

SINT Technology can provide a wide range of acoustics services, from reliable measurements to analysis of results

and comparison with the limits laid down by the law and international standards, to designing solutions to reduce

noise.

Our services are characterised by:

the professionalism guaranteed by highly skilled engineering techni-

cians

dynamism and flexibility

willingness to perform testing on the customer's plant in all parts of the

world

detailed reporting in accordance with the customer's requirements and

SINT Technology operates in va-

rious areas

OIL & GAS

Energy

Rail

Automotive

Civil

Page 4: Acoustic - sintechnology.com · EN ISO 11200 EN ISO 11201 EN ISO 11202 EN ISO 11203 EN ISO 11204 Macchine industriali Sorgenti di rumore Determination of sound power levels of noise

SINT Technology s.r.l. Tel: +39.055.8826302 · Fax: +39.055.8826303 · [email protected] · www.sintechnology.com

Acoustic Sound Level and Sound Intensity Measurements

Environmental noise, understood as unwanted or harmful noise from ou-

tside, is spreading both in terms of duration and geographical area. Noise

is associated with numerous human activities but it is the noise caused by

motor vehicles, trains and aircraft that produces the greatest impact. This

is a problem particularly for urban areas; approximately 75% of the popu-

lation in Europe lives in cities and the volume of traffic is continuing to

grow.

Measurement and analysis of noise in industry and in the workplace

Measurement and analysis of environmental noise

The risk of noise hazards depends primarily on the sound power level present in the workplace and on the length

of daily exposure.

Prolonged exposure to high noise levels can cause not only hearing impairment but it also acts as a causal factor

for hypertension, acceleration of heart rate, and other chronic conditions, for example, ischaemic heart disease,

stress, sleep disorders, etc..

SINT Technology is familiar with the prevention principles (reduction of noise at source, limitation of propagation

of sound waves with structural provisions, etc.), the related regulations and compliance requirements of busines-

ses and local authorities and is able to provide comprehensive professional services both from the point of view of

instrumentation and for technical advice.

SINT Technology can provide professional guidance for fulfilment of all the obligations set out in the standards:

Assessment of the level, type and duration of exposure

Comparison with the action values and exposure limit values

Choice of personal hearing protectors with adequate noise reduction

Study, design and implementation of acoustic quieting

Information and training for workers

SINT Technology has competent certified engineers and with its technical skill, stock of instruments and experien-

ce it is able to carry out the necessary measurements and design the necessary corrective measures.

Measurement of sound power level issued by machinery and plants

Sound pressure method

ISO 3743-1 - Acoustics -- Determination of sound power levels of noise sources – Engineering methods for

small, movable sources in reverberant fields -- Part 1: Comparison method for hard-walled test rooms

ISO 3744 - Acoustics -- Determination of sound power levels of noise sources using sound pressure -- Enginee-

ring method in an essentially free field over a reflecting plane

Page 5: Acoustic - sintechnology.com · EN ISO 11200 EN ISO 11201 EN ISO 11202 EN ISO 11203 EN ISO 11204 Macchine industriali Sorgenti di rumore Determination of sound power levels of noise

SINT Technology s.r.l. Tel: +39.055.8826302 · Fax: +39.055.8826303 · [email protected] · www.sintechnology.com

Acoustic Sound Level and Sound Intensity Measurements

Sound intensity method

The measurement of sound intensity makes it more straightforward to determine the sound power of a source,

particularly as it dispenses with the costly and complicated installation of an anechoic or reverberant room. SINT

Technology offers this service in accordance with the latest standards, ie:

ISO 9614-1 - Acoustics -- Determination of sound power levels of noise sources using sound intensity -- Part 1:

Measurement at discrete points

ISO 9614-2 - Acoustics -- Determination of sound power levels of noise sources using sound intensity --

Part 2: Measurement by scanning

The measurement of emitted sound power by the sound intensity method is the ideal solution for complying with

the requirements of the directive on the noise emission of outdoor machinery: Executive Order no. 262, of 4 Sep-

tember 2002.

This directive regulates the acoustic emissions of over

50 types of machines and equipment used outdoors,

establishing the procedures that manufacturers have to

follow in order to be able to affix the marking indicating

conformity to the directive, consisting of the initials “CE”

and of indication of the guaranteed noise level.

Advantages

Immunity from background noise ,

improved precision,

identification, isolation and classification of individual noise sources

A sound intensity probe measures only the component of sound energy that flows parallel to the axis of the pro-

be. The flow of sound energy towards the probe is measured as positive intensity while the flow of sound energy

in the opposite direction is considered negative.

When measurements are made with the sound intensity probe on enveloping surface, background sound goes in

one side of the surface and out the opposite side. Background noise is therefore cancelled and the measurement

includes only the noise that originates inside the measurement area. The effects of the measurement environment

are thus eliminated in the same way.

Page 6: Acoustic - sintechnology.com · EN ISO 11200 EN ISO 11201 EN ISO 11202 EN ISO 11203 EN ISO 11204 Macchine industriali Sorgenti di rumore Determination of sound power levels of noise

SINT Technology s.r.l. Tel: +39.055.8826302 · Fax: +39.055.8826303 · [email protected] · www.sintechnology.com

Acoustic Sound Level and Sound Intensity Measurements

Measurements on site

In the past, accurate measurement of sound power levels required that a machine or component be sent to an

anechoic room in an acoustics laboratory

The sound intensity method now offers the possibility of performing very accurate measurements at the custo-

mer’s plant or premises without interruption to processes or business.

Site measurements save time, cut costs and permit iterative tests for research and development applications.

Architectural acoustic design

It is interesting to note how methods and systems for

describing and quantifying the acoustic performance of

buildings have been advanced by academics over the

years, identifying numerous parameters which are more

or less useful for understanding the mechanism that

produces the quality necessary for good listening; whe-

reas the design issue of how to select the most suitable

materials to meet the necessary acoustics and safety

requirements is more difficult, considering also existing

volumes layouts and architectural form, which have to

The acoustic requisites of halls for use by the public are the set of technical specifications that form the basis for

the executive design of acoustic works.

Page 7: Acoustic - sintechnology.com · EN ISO 11200 EN ISO 11201 EN ISO 11202 EN ISO 11203 EN ISO 11204 Macchine industriali Sorgenti di rumore Determination of sound power levels of noise

SINT Technology s.r.l. Tel: +39.055.8826302 · Fax: +39.055.8826303 · [email protected] · www.sintechnology.com

Acoustic Sound Level and Sound Intensity Measurements

Instrumentation

SINT Technology has a vast array of noise measurement and analysis equipment.

The main instruments are:

Class 1 integrating sound level meters

½ inch microphones

Acoustic calibrators for microphones

Two-microphone sound intensity probe

Sound intensity probe calibrator

Standards

Field of application Description Standard Code

Noise emitted by machinery

and equipment

Measurement of emission sound pressure levels at

a work station and at other specified positions

EN ISO 11200

EN ISO 11201

EN ISO 11202

EN ISO 11203

EN ISO 11204

Macchine industriali

Sorgenti di rumore

Determination of sound power levels of noise sour-

ces

EN ISO 3744

EN ISO 3746

Determination of sound power levels of noise sour- EN ISO 9614-2

Environmental noise

Work environment

Measurement of sound pressure levels

DPCM 01/03/1991

L n° 447 26/10/1995

DPCM 14/11/1997

DM 16/03/1998

DPCM n° 215 16/04/1999

Determination of noise exposure D.Lgs 81/08

UNI 9432

UNI EN ISO 9612

Industrial plants

Plants with gas turbines

Measurement of industrial noise ANSI/ASME PTC 36

Guide to evaluation of the impact of noise on the

environment in gas turbine installations

UNI 9572

Measurement of emitted airborne noise – Enginee- ISO 10494

Rotating electrical machines

Noise emitted by machinery

and equipment

Test codes for the measurement of airborne noise

emitted by rotating electrical machines

ISO 1680

Page 8: Acoustic - sintechnology.com · EN ISO 11200 EN ISO 11201 EN ISO 11202 EN ISO 11203 EN ISO 11204 Macchine industriali Sorgenti di rumore Determination of sound power levels of noise

SINT Technology s.r.l. Tel: +39.055.8826302 · Fax: +39.055.8826303 · [email protected] · www.sintechnology.com

Contact Us

Via delle Calandre, 63 - 50041 Calenzano (FI) ITALY

Tel: +39.055.8826302

Fax: +39.055.8826303

www.sintechnology.com

[email protected]

VAT IT04185870484

Recognitions

SINT Technology’s test laboratory is accredited to standard ISO/IEC

17025:2005 by the Italian accreditation body ACCREDIA with

certificate no. 0910

Certification of conformity to the requirements of standard

UNI EN ISO 9001