With Auto-Dialer and Communicator6 ZONE MINI ALARM CONTROL PANEL
BoxALALARM SYSTEM
6 ZO
NE
ALA
RM
CO
NTR
OL
PA
NEL ACP 611
Two 32 Digit telephone numbers
for communicator
Four 32 digit telephone numbers
for auto-dialer
Tone dialing (DTMF) or pulse dialing possible
Communicator data in DTMF
Formal with check-sum
Remote Arm-Disarm from any DTMF
Telephone or mobile phone
Programmable pause time between any digits
Alarm / status reports from communicator
to monitor station
Programmable voice message and numeric message
for auto dialer
ACP 611 is an alarm control panel with 6 hardware protection zones and 2 software zones for panic and duress
alarms. which is designed for home and office protections using the latest security concept It is built-in with voice auto-
dialer and data communicator in one unit. when alarm occurs. it gives local alarm warnings as like the traditional alarm
system and it also sends out the alarm status information to the monitor station and voice message and/or numeric
message to the pre-set telephones and/or personal pagers. as the system reports alarm event through multiple media
to the appropriate parties, which guarantees that no alarm reporting will be lost even one of the parties is not on duty.
the ACP611 alarm control panel is fully compatible with the ALARM-MONITOR software MS-980 which Is an Ideal tool
in setting up an alarm monitor station with personal computer for the small to medium size community, such as a
monitor station at an estate management office, the security control office of a commercial residential building and
even a police sub-station. the ACP 611 is compatible with all the public telephone systems.
Each ACP 611 comes with built-in full feature control console. auxiliary control consoles are required to
purchase separately. Both console are having the same functions except the built-in microphone for message
recording is not available on the auxiliary control console.
20 Seconds non-volatile
User programmable voice message
Controllable & prolongable listen-in duration
Back-Up or non-back-up alarm reporting
Telephone line fault detection at arm-disarm control
Programmable of dialing attempts, 8 attempts maximum
Programmable of message repeats, 8 repeats maximum
Selection of communicator & dialer calling combinations
Telephone numbers can be tested individually
Use existing telephone line, no additional line is required
Compatible with all the public telephone systems &
those PBX systems using tone-dialing telephone
Main Features Of The Auto Dialer & Communicator
Introduction
1 2 3 4 5 6 7 8EXIT/ARMED
ACPOWER
BATTERY
PROGRAM
ARMPROHIBITED
DIALING
RECORDING
MIC
ZONES
PROFESSIONAL ALARM SYSTEM
“ Your safety and security is our priority “
Auxilary control keypad(optional)
BoxALALARM SYSTEM
SpecificationModel
Power source
Backup battery requirement
Temperature range
Standby current
Protection zones
Control station
G. Weight
Dimensions (mm) Master unit
Optional control console
ACP 611
12 - 16 VDC, 1.5 Amp
1.2AH, 12V, Rechargeable lead acid battery
0 C to + 65 C
100 mA
6 Protection zones, end of-line resistor supervised
Full function control station
0.9 Kg
175(W) x 110 (H) x 61 (D)
117 (H) x 117 (W) x 27 (D)
6 Zones. programmable for Instant delay.
24 hour Instant or 24 hour silent alarm reporting
Programmable master code, client code & 8 user codes
All user codes with duress function
Protection zones are programmable for single or multiple triggering
Programmable timers for exit delay, entry delay 1 & 2. and alarm duration
Arm-Disarm on site or remotely from any DTMF telephone or mobile phone
Programmable response time for each protection zones
Arm-Disarm ring back notifications
Exit and entry beep ON-OFF options
Instant arming codes for home or away operation
Built-in dynamic battery charger and tester
Periodically auto or manual battery testing
On board activation or panic and duress alarms
Maximum 3 auxiliary control consoles can be connected
Home and away operations
Forced to arm or arm prohibited options
Handover operation option tor Instant zones
Connection facilities for siren/beII, satellite siren and strobe light
Power low watchdog resets system before battery exhausted
Non-Volatile memory
12V 1.2Ah Back-Up battery (not included)
12-16V DC operation (power adaptor not included)
Tamper-proof
Weight Control panel - 1,2Kg. (Metal box)
Control console - 220g. (Plastic box)
Dimension: Control panel - 116(H) x 180(W) X 67(D)mm
Control console - 117(H) x 117( W) x 27(D)mm
Main Features Of The Alarm Control Panel
LOCAL ALARM
MODEM
AUTO-PAGERSTATION
TELEPHONE
MOBILE PHONE
POLICE
CLIENT
PROPERTY MANAGEMENT OFFICE
SECURITY GUARD
CLIENT’S PERSONAL PAGER
MOTION DETECTOR
MAGNETIC CONTACT
GLASS BREAK DETECTOR
PANIC BUTTON
SMOKE DETECTOR
OTHER DETECTOR
ALARMINFORMATION
MONITOR STATION
Alarm Monitor Software MS-980PUBLIC
TELEPHONENETWORK
Note : MS-980 software is optional
Alarm Control Panel Configuration
ACP611
ALARM CONTROL PANEL