2
With Auto-Dialer and Communicator 6 ZONE MINI ALARM CONTROL PANEL Box AL ALARM SYSTEM 6 ZONE ALARM CONTROL PANEL ACP 611 Two 32 Digit telephone numbers for communicator Four 32 digit telephone numbers for auto-dialer Tone dialing (DTMF) or pulse dialing possible Communicator data in DTMF Formal with check-sum Remote Arm-Disarm from any DTMF Telephone or mobile phone Programmable pause time between any digits Alarm / status reports from communicator to monitor station Programmable voice message and numeric message for auto dialer ACP 611 is an alarm control panel with 6 hardware protection zones and 2 software zones for panic and duress alarms. which is designed for home and office protections using the latest security concept It is built-in with voice auto- dialer and data communicator in one unit. when alarm occurs. it gives local alarm warnings as like the traditional alarm system and it also sends out the alarm status information to the monitor station and voice message and/or numeric message to the pre-set telephones and/or personal pagers. as the system reports alarm event through multiple media to the appropriate parties, which guarantees that no alarm reporting will be lost even one of the parties is not on duty. the ACP611 alarm control panel is fully compatible with the ALARM-MONITOR software MS-980 which Is an Ideal tool in setting up an alarm monitor station with personal computer for the small to medium size community, such as a monitor station at an estate management office, the security control office of a commercial residential building and even a police sub-station. the ACP 611 is compatible with all the public telephone systems. Each ACP 611 comes with built-in full feature control console. auxiliary control consoles are required to purchase separately. Both console are having the same functions except the built-in microphone for message recording is not available on the auxiliary control console. 20 Seconds non-volatile User programmable voice message Controllable & prolongable listen-in duration Back-Up or non-back-up alarm reporting Telephone line fault detection at arm-disarm control Programmable of dialing attempts, 8 attempts maximum Programmable of message repeats, 8 repeats maximum Selection of communicator & dialer calling combinations Telephone numbers can be tested individually Use existing telephone line, no additional line is required Compatible with all the public telephone systems & those PBX systems using tone-dialing telephone Main Features Of The Auto Dialer & Communicator Introduction 1 2 3 4 5 6 7 8 EXIT/ ARMED AC POWER BATTERY PROGRAM ARM PROHIBITED DIALING RECORDING MIC ZONES PROFESSIONAL ALARM SYSTEM “ Your safety and security is our priority “ Auxilary control keypad (optional)

ACP611

Embed Size (px)

Citation preview

Page 1: ACP611

With Auto-Dialer and Communicator6 ZONE MINI ALARM CONTROL PANEL

BoxALALARM SYSTEM

6 ZO

NE

ALA

RM

CO

NTR

OL

PA

NEL ACP 611

Two 32 Digit telephone numbers

for communicator

Four 32 digit telephone numbers

for auto-dialer

Tone dialing (DTMF) or pulse dialing possible

Communicator data in DTMF

Formal with check-sum

Remote Arm-Disarm from any DTMF

Telephone or mobile phone

Programmable pause time between any digits

Alarm / status reports from communicator

to monitor station

Programmable voice message and numeric message

for auto dialer

ACP 611 is an alarm control panel with 6 hardware protection zones and 2 software zones for panic and duress

alarms. which is designed for home and office protections using the latest security concept It is built-in with voice auto-

dialer and data communicator in one unit. when alarm occurs. it gives local alarm warnings as like the traditional alarm

system and it also sends out the alarm status information to the monitor station and voice message and/or numeric

message to the pre-set telephones and/or personal pagers. as the system reports alarm event through multiple media

to the appropriate parties, which guarantees that no alarm reporting will be lost even one of the parties is not on duty.

the ACP611 alarm control panel is fully compatible with the ALARM-MONITOR software MS-980 which Is an Ideal tool

in setting up an alarm monitor station with personal computer for the small to medium size community, such as a

monitor station at an estate management office, the security control office of a commercial residential building and

even a police sub-station. the ACP 611 is compatible with all the public telephone systems.

Each ACP 611 comes with built-in full feature control console. auxiliary control consoles are required to

purchase separately. Both console are having the same functions except the built-in microphone for message

recording is not available on the auxiliary control console.

20 Seconds non-volatile

User programmable voice message

Controllable & prolongable listen-in duration

Back-Up or non-back-up alarm reporting

Telephone line fault detection at arm-disarm control

Programmable of dialing attempts, 8 attempts maximum

Programmable of message repeats, 8 repeats maximum

Selection of communicator & dialer calling combinations

Telephone numbers can be tested individually

Use existing telephone line, no additional line is required

Compatible with all the public telephone systems &

those PBX systems using tone-dialing telephone

Main Features Of The Auto Dialer & Communicator

Introduction

1 2 3 4 5 6 7 8EXIT/ARMED

ACPOWER

BATTERY

PROGRAM

ARMPROHIBITED

DIALING

RECORDING

MIC

ZONES

PROFESSIONAL ALARM SYSTEM

“ Your safety and security is our priority “

Auxilary control keypad(optional)

Page 2: ACP611

BoxALALARM SYSTEM

SpecificationModel

Power source

Backup battery requirement

Temperature range

Standby current

Protection zones

Control station

G. Weight

Dimensions (mm) Master unit

Optional control console

ACP 611

12 - 16 VDC, 1.5 Amp

1.2AH, 12V, Rechargeable lead acid battery

0 C to + 65 C

100 mA

6 Protection zones, end of-line resistor supervised

Full function control station

0.9 Kg

175(W) x 110 (H) x 61 (D)

117 (H) x 117 (W) x 27 (D)

6 Zones. programmable for Instant delay.

24 hour Instant or 24 hour silent alarm reporting

Programmable master code, client code & 8 user codes

All user codes with duress function

Protection zones are programmable for single or multiple triggering

Programmable timers for exit delay, entry delay 1 & 2. and alarm duration

Arm-Disarm on site or remotely from any DTMF telephone or mobile phone

Programmable response time for each protection zones

Arm-Disarm ring back notifications

Exit and entry beep ON-OFF options

Instant arming codes for home or away operation

Built-in dynamic battery charger and tester

Periodically auto or manual battery testing

On board activation or panic and duress alarms

Maximum 3 auxiliary control consoles can be connected

Home and away operations

Forced to arm or arm prohibited options

Handover operation option tor Instant zones

Connection facilities for siren/beII, satellite siren and strobe light

Power low watchdog resets system before battery exhausted

Non-Volatile memory

12V 1.2Ah Back-Up battery (not included)

12-16V DC operation (power adaptor not included)

Tamper-proof

Weight Control panel - 1,2Kg. (Metal box)

Control console - 220g. (Plastic box)

Dimension: Control panel - 116(H) x 180(W) X 67(D)mm

Control console - 117(H) x 117( W) x 27(D)mm

Main Features Of The Alarm Control Panel

LOCAL ALARM

MODEM

AUTO-PAGERSTATION

TELEPHONE

MOBILE PHONE

POLICE

CLIENT

PROPERTY MANAGEMENT OFFICE

SECURITY GUARD

CLIENT’S PERSONAL PAGER

MOTION DETECTOR

MAGNETIC CONTACT

GLASS BREAK DETECTOR

PANIC BUTTON

SMOKE DETECTOR

OTHER DETECTOR

ALARMINFORMATION

MONITOR STATION

Alarm Monitor Software MS-980PUBLIC

TELEPHONENETWORK

Note : MS-980 software is optional

Alarm Control Panel Configuration

ACP611

ALARM CONTROL PANEL