29
ABB standard drive Enhanced ACS550

ACS550 Presentation

Embed Size (px)

DESCRIPTION

Presentation for ACS550

Citation preview

ABB standard drive Enhanced ACS550

AC

S55

0 ©

AB

B O

y. -

2

ACS550, Standard Drive

ABB Standard Drive Part of the family - The ABB Drive

Reliable quality product Global support

Convenient with all the aspects Simple selection Excellence in connectivity Intuitive drive All inside as standard Proven Performance

AC

S55

0 ©

AB

B O

y. -

3

ACS550, Standard Drive

0,75 to 5,5 kW

up to 11 kW

up to 22 kW

up to 45 kW

up to 55 kW

up to 132 kW

up to 160 kW

up to 355 kW

Complete power range 0.75 - 355 kW, 1 - 500 HP 3 phase 230 V (up to 75 kW) and

400 V series IP21 / UL Type 1 IP54 / UL Type 12 (R1-R6 only)

AC

S55

0 ©

AB

B O

y. -

4

ACS550, Standard Drive Installation

550-01 Mounting options Wall Side-by-Side Flange

550-02 Mounting options Free standing Side-by side

AC

S55

0 ©

AB

B O

y. -

5

Convenience with all the aspects

AC

S55

0 ©

AB

B O

y. -

6

ACS550 – Selection

Relay Output Extension +L511

Type code shows output current and input voltage Control options can be ordered using plus codes or

as separate option kits

ACS550-01-06A9- 4+L511+K451

Output Current6.9 A

Input Voltage380 to 480 V

DeviceNet Adapter+K451

AC

S55

0 ©

AB

B O

y. -

7

ACS550 – Selection

ACS550 ratings

AC

S55

0 ©

AB

B O

y. -

8

ACS550 – Selection

Dimensions are in [mm]

R1 R2 R3 R4

369

212125

469

222125

583

231 203

262203

689

AC

S55

0 ©

AB

B O

y. -

9

ACS550 – Selection

Dimensions are in [mm]

R5 R6R7

R8

739

286 265

880

400300

1507

250 520

2024

347617

AC

S55

0 ©

AB

B O

y. -

10

ACS550 - Connectivity

Relay OutputExtension (3 x RO)

Plug-in Fieldbus Modules

Inbuilt Modbus

Extensive I/O- 2 x AI- 2 x AO- 6 x DI- 3 x RO

Easy connection to factory automation systems through multiple I/Os and plug-in options

AC

S55

0 ©

AB

B O

y. -

11

ACS550 - Connectivity

IO is galvanic isolated as groups

RO

DI

AI / AO

AC

S55

0 ©

AB

B O

y. -

12

ACS550 - Connectivity

550 supports the new parameterization tool FlashDrop

For selecting and setting parameters Parameter set for non-connected drive In warehouse or during mechanical

installation Possibility to hide selected parameters

Machine protection Only essential parameters are shown

FlashDrop connection behind the control panel - protection class will remain

AC

S55

0 ©

AB

B O

y. -

13

ACS550 - Connectivity

All FBs are either embedded or mechanically installed inside the drive Modbus is the embedded fieldbus ACS 800 type Fieldbus modules are used to

provide remaining FBs Available fieldbuses:

PROFIBUS DeviceNet LonWorks ControlNet CANopen Ethernet (Modbus TCP & Ethernet/IP)

AC

S55

0 ©

AB

B O

y. -

14

ACS550 - Intuitive

Assistant control panel functions Run the assistants in conjunction with drive software Has help button giving manual information List of changed parameters Real time clock Fault Logger 15 languages supported in one panel

AC

S55

0 ©

AB

B O

y. -

15

ACS550 - Intuitive Basic control panel

7 segment display Implement panel protocol to display and modify parameters Upload or download capabilities Backlight

AC

S55

0 ©

AB

B O

y. -

16

ACS550 - Intuitive Buttons of the Assistant control panel:

Soft key 2

Help button

Start button

Soft key 1

Loc / Rem mode

Stop button

Soft key 2 Function

Soft key 1 function

Up and down buttons (to change parameters and their values)

AC

S55

0 ©

AB

B O

y. -

17

ACS550 - Intuitive

Start - Up assistantStart - Up assistant guides the user through all essential settings to be done without going directly into the parameter list.

Maintenance assistantMaintenance assistant can set the drive a criteria to insert preventive maintenance.

Timer Assistant helps in using timed functions Serial Communication Assistant for making

fieldbus setup simple and easy PID Assistant for feedback scaling and setting Drive Optimizer to optimize the drive in different

aspects Noise Efficiency Motor control performance

Assistants in the panel

AC

S55

0 ©

AB

B O

y. -

18

ACS550 - Intuitive

Fault Logger (Assistant panel only)

Easy way to find out What happened When happened

Tells drive status at the point of time the fault occurred Frequency, speed, torque, current, voltage etc…

Example: Panel Loss – fault 10 Panel tells the operator to “check: comm lines and connections,

parameter 3002, parameters in groups 10 and 11”

AC

S55

0 ©

AB

B O

y. -

19

ACS550 - Intuitive

AC

S55

0 ©

AB

B O

y. -

20

ACS550 - Intuitive

DriveWindow Light 2 For commissioning the drive Possibility to monitor the drive Assistant to create direct configuration of the drive Remains compatible to other Low Voltage AC Drive

products

AC

S55

0 ©

AB

B O

y. -

21

The old way to do it...

ACS550 - All inside

…And ACS550

Built-in: - RFI filter, input choke, braking chopper (R1&R2), Modbus-(other fieldbuses as internal plug-in options)

EMC filter

Braking chopper input

choke

AC

S55

0 ©

AB

B O

y. -

22

ACS550 - All inside

Basic control panelAssistant control panel(as standard)

Plug-in Fieldbus

Relay OutputExtension Module

ACS550 internal options

AC

S55

0 ©

AB

B O

y. -

23

ACS550 – All inside

EMC filter

Cable lengths for 1st environment 75 – 300 m Cable lengths for 2nd environment 100 – 300 m

Detailed table on cable lengths available EMC environment explanation

AC

S55

0 ©

AB

B O

y. -

24

ACS550 – All inside New way to suppress harmonics caused by the inverter

“swinging choke”swinging choke” At partial load the swinging choke reactance increases THD reduction up to 24.2% compared to traditional choke

AC

S55

0 ©

AB

B O

y. -

25

ACS550 – All inside

“Swinging Choke” Designed to reduce harmonics at full and partial

loads Perfect for Variable Torque Centrifugal Loads

AC

S55

0 ©

AB

B O

y. -

26

ACS550 – Performance

Sensorless vector control Up to 12 kHz switching frequency at reduced current for

R1-R4 Automatic noise reduction

Switching frequency goes up when load decreases Noise smoothing function

Motor thermistor input (both PT 100 and PTC) Two independent PIDs On - Off controlled cooling fan

AC

S55

0 ©

AB

B O

y. -

27

ACS550 – Performance Scalar control for easy start-up and multi-motor

applications Sensorless Vector providing very good performance

Step load response (Dynamic accuracy)Vector Control

00.10.20.30.40.50.60.70.80.9

150 750 1500

Speed [rpm]

Stiff

ness

[%s]

ACS550

Competitor A

Competitor B

AC

S55

0 ©

AB

B O

y. -

28

Convenience with all the aspects

AC

S55

0 ©

AB

B O

y. -

29