Upload
ashutosh2009
View
216
Download
2
Embed Size (px)
DESCRIPTION
tender
Citation preview
Sl. No Item Description Megger Suggested model Megger 's Unique feature over competitor 1
MTO210 ,TTR310
2
S1-1068
3
Delta 4110
4
OTS 60 AF
5
Frax 101
6
Part no-
118308082-S
7 TM1740
BL-49192(QTY-1),
SDRM202 ▪▪Four standard models. Full stand-alone
CG- functionality or data acquisition models without user interface
90200(QTY-1),
GA-00851(QTY-3)
8 MOM200A
10DET4TCR2 CAT IV , 3/4 pole , rugged , optional clamp type connector.
11
SMRT36-
Transformer Winding resistance meter & turns ratio meter
Highest ratio measurement (45,000:1); highest accuracy (0.1%)Auto Vecter Group Detection , , Magnetic Balance all in one kit ( TTR 310 ) , Simultaneous measurement of rimary and secondary (MTO 210 -single phase ) ,Patented Current Smoothing technique for fast & convenient testing on large PT (MTO 210)
Insulation Resistance (IR) Tester (10KV) High test current 6mA ,High guard terminal performance,CAT IV 600V
safety ,High noise immunity 8mA,IP65 sealed case,Live Streaming of output data,Mains or battery operation (both independent of each other ,Wide Insulation Resistance Range ,Wireless connection for Laptop communication
Automatic Capacitance & Tandelta Measuring Instrument
Industry's Compact Size Design ,Independent Line Frequency Measurement,Design To Work in High Interference S/S,Individual Temperature Correction(ITC),Voltage Dependent Detection(VDD),Wide Frequency Range (1-500Hz),Automatic and manual operation Industry's Fastest Test Times,
Break Down Voltage (BDV) Test Kit for Oil (60 KV)
Ultra Fast (<10 Micro Second) Switch Off Time Standards specify maximum times for the arc to be present and are usually in regions of 10 milliseconds IEC-156 , Lighestportable kit in the world ,Inbulit temperature sensor
Frequency Response Analyser (FRA) test set
Wide Dyanamic Range -130dB ,Variable Output Voltage ,Wide Measurement Points 32000 ,System Integrity Test ,Import & Export Other Manufacturer Data ,Analyzers For Decision Support ,Wireless Commutation ,Light Weight & Battery Operated ,Only Unit Which Complying All Standards
Partial Discharge (PD) Measuring Instrument
PDS AIR(for cables, switchgear)
Portable kit with 3 diffect sensors for test variety of areas/places
Circuit Breaker operational Analyser& Dynamic contact Resistance Meter (DCRM) test kit
▪▪Fast and safer with Patented DualGround™ testing, grounding from both sides
GA-12810(QTY-1),XB-51020(QTY-1),XB-30117(QTY-1)
Static Contact Resistance Measuring Instruments Patented Dual ground proctection , Smallest kit to inject 200
Amps BD-12390(QTY-1),GA-03103(QTY-1)
Earth Tester for Measurement of soil resistivity & ground resistance
Automatic Relay Test Kit suitable for testing electro mechanical/Static/ numerical relays ,
Small , rugged , portable , Modula design , Conertable voltage /current channels , high power/current output per phase 300VA/60A , optional Transducer testing facility , High Burden
11
30P0F0I0S1
12NiM 1000 A
13
14 Karl Fisher Testing Oil Testing Kit KF 875 Easy to Use , ACE control system , Low drift cell16 Leakage Current Detector DCM300E Highest Range of current upto 3000 Amp 17
ODEN AT
18 Recovery Voltage Measurement KitIDAX300
19
Automatic Relay Test Kit suitable for testing electro mechanical/Static/ numerical relays ,
Small , rugged , portable , Modula design , Conertable voltage /current channels , high power/current output per phase 300VA/60A , optional Transducer testing facility , High Burden
Transmission Line Response Analyser
portable , rugged , Display R,X ,Z live measurement , 1000A current procduction capacity
Puncture Insulator Detector (PID) ??
Portable Multi Functional Primary CT Injection Kit Most Advanced Primary Current Injection
Test System to simplify all types ofswitchgear and CT commissioning, groundgrid, circuit breaker testing and more,Modular design to permit optimaluser configuration of output currentvs. unit size ,Compact transport cart facilitatesportability into switchgear roomswith limited space ,Unique I/30 function allows the current tobe pre-set using low current to preventtest sample heating, thus eliminatingcorruption of test result
IDAX300 competes directly with Omicron Dirana and for moisture assessment also
Protection Suite Software for Relay Data Base Management & Analysis with the PDC analyzer Alff PDC-ANALYSER-1MOD. Omicron
claims that their ,design performs much faster moisture measurements than IDAX which is NOT,TRUE at typical measurement temperatures. Omicron has no high voltage amplifier, no real-time waveform capture. Alff PDC instrument has longer measurement time, is sensitive for hum and noise and has a limited frequencyrange. Tettex offer the RVM (Return Voltage Measurement) product Type 5462. Their unit has been included in numerous comparative studies but has always come out with bad reviews because of poor accuracy, noise sensitivity and lack of reliable interpretation SW.