9
TORNIER AEQUALIS ASCEND FLEX Convertible Shoulder System

AEQUALIS ASCEND FLEX · CO Tournier.pdf Author: Memenks Created Date: 5/21/2019 10:55:20 AM

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: AEQUALIS ASCEND FLEX · CO Tournier.pdf Author: Memenks Created Date: 5/21/2019 10:55:20 AM

TORNIER

AEQUALIS ASCEND™ FLEXConvertible Shoulder System

Page 2: AEQUALIS ASCEND FLEX · CO Tournier.pdf Author: Memenks Created Date: 5/21/2019 10:55:20 AM

W E E X P E C T M O R E T H A N O T H E R S T H I N K I S P O S S I B L E .

Page 3: AEQUALIS ASCEND FLEX · CO Tournier.pdf Author: Memenks Created Date: 5/21/2019 10:55:20 AM

AEQUALIS ASCEND™ FLEXConvertible Shoulder System

AEQUALIS™ REV IIThreaded Post Baseplate

AEQUALIS™ PERFORM™

Glenoid System

Preservation. Fixation. Performance. Conversion.

Page 4: AEQUALIS ASCEND FLEX · CO Tournier.pdf Author: Memenks Created Date: 5/21/2019 10:55:20 AM

Fixation and Conversion.

Page 5: AEQUALIS ASCEND FLEX · CO Tournier.pdf Author: Memenks Created Date: 5/21/2019 10:55:20 AM

FixationANATOMICALLY DERIVED STEM DESIGN Mimics the internal humeral geometry to maximize proximal fixation.

PLASMA SPRAY COATING Creates immediate and long-term fixation.

ConversionCONVERTIBLE DESIGN Simply adapts from anatomic to reverse without stem removal.

SHORT STEM & COLLARLESS DESIGN Simplify stem removal, when needed.

al fixationxation

Page 6: AEQUALIS ASCEND FLEX · CO Tournier.pdf Author: Memenks Created Date: 5/21/2019 10:55:20 AM

Fixation and Performance.

Page 7: AEQUALIS ASCEND FLEX · CO Tournier.pdf Author: Memenks Created Date: 5/21/2019 10:55:20 AM

FixationCENTRAL THREADED POST Provides immediate baseplate fixation.

PLASMA SPRAY COATING Creates long-term baseplate fixation.

VARIABLE LOCKING SCREWS Enhance baseplate fixation.

Performance 145° INCLINATION Optimizes range of motion & reduces notching.

ECCENTRIC REVERSED TRAYS Adjust for variation in stem placement & simplify conversion.

LATERALIZED GLENOID OPTIONS Decrease scapular notching.

Page 8: AEQUALIS ASCEND FLEX · CO Tournier.pdf Author: Memenks Created Date: 5/21/2019 10:55:20 AM

Bone Preservation.

Page 9: AEQUALIS ASCEND FLEX · CO Tournier.pdf Author: Memenks Created Date: 5/21/2019 10:55:20 AM

Excessive ReamingARTHRITIC VARIABILITYArthritic glenoid articular curvatures are 22% flatter and have 3X more variance than non-arthritic glenoids.1

TRADITIONAL REAMERSTraditional reamer curvatures were derived from non-arthritic cadaveric specimens.

CLINICAL OUTCOMESExcessive reaming to achieve backside fit with traditional reamers is a leading cause in long-term glenoid loosening.2,3

PreservationMULTIPLE CURVATURES PER SIZEReamers and implants adapt to arthritic anatomy preserving subchondral bone and structural integrity.

Glenoid Curvature

AEQUALIS™ PERFORM™ Glenoids

Traditional GlenoidsCurved

Glenoid

Flat Glenoid

Glenoid Curvature Comparison

Glenoid Reaming Comparison

In our data collection, 75% of arthritic glenoids had an articular radius curvature that fell outside of 30-35mm, and 50% fell outside of 30-40mm.1

Glenoid Sample

Preserve up to 68% more bone when compared to traditional glenoid systems.1

Volume Reamed

(mm3)

TRADITIONAL REAMER

AEQUALIS™ PERFORM™ REAMER

30 mm

35 mm X

40 mm X

50 mm X

60 mm X