Celtest Company Limited. Registered in Wales and England 1533370. Vat No. 352-5034-81 Trefelin Bangor Gwynedd LL57 4LH T +44 (0)1248 355269 F +44 (0)1248 351563 E postmaster celtest.com W www.celtest.com @ 0494 Aggregate Testing - 2017 Test List Aggregate Mechanical and Physical Testing No. 4-8-02-1994 Appendix B Drying Shrinkage BS 812: Part 124 UKAS 300mm Shear Box Apparent Bulk Density of Filler Horizontal Permeability Inc. PSD Alkali Reactivity - Mortar bar method (16 day) Polished Stone Value (PSV) EN 1097-8 UKAS BS 1377: Part 7 & SHW Volume 1 Clause 639 - Granular Material Cohesive Material (per loading) BS EN 1097-3 Aggregate Abrasion Value (AAV) Aggregate Crushing Value (ACV) Petrographic Examination Fine BS812 - 104 BS812 - 104 EN 933-5 Aggregate Impact Value - Dry (AIV) Aggregate Impact Value - Soaked (AIV) Petrographic Examination Coarse Petrographic Examination Fine Granular Material ITP 1 (Based on BS812-104) Alkali Silica Reactivity (Concrete Prism Method) BS 812: Part 123 Angle of Internal Friction & Adhesion Accreditation Description Method ASTM C1260 SHW Volume 1 Clause 636 - Angle of Internal Friction & Adhesion 300mm Shear Box BS EN 1097-8: Annex A BS 812: Part 110 Constituent Materials Dicalcium Silicate Disintegration Compaction Fraction Drying Shrinkage BS EN 933-11 Iron Disintegration EN 1744-1 including Annex B UKAS extra over per day Frost Susceptibility Bond Work Index Bulk Density & Void (Loose & Compacted) with Reinforcing Elements Supplied Cohesive Material (per loading) extra over per day EPRI Report CS3612:FGD BS 812: Part 112 BS 812: Part 112 BS 1377: Part 7 & UKAS UKAS EN 1097-3 UKAS UKAS UKAS UKAS UKAS UKAS EN 1097-1: Annex A UKAS Water Industries Spec. Micro Deval (MD RB ) Laboratory Dry Density & Optimum Water Content Micro Deval (Wet or Dry) UKAS EN 1097-2: Annex A Flakiness Index EN 1097-1 UKAS UKAS UKAS DTP HA 41/90 UKAS UKAS EN 933-1 ITP 1 (Based on BS812-104) UKAS EN 933-10 UKAS Particle Size Distribution (Air-Jet Sieving) Petrographic Examination Coarse in Coarse Aggregate Percentage of Shells in Coarse Aggregate EN 933-7 UKAS UKAS Percentage Crushed & Broken Surfaces Resistance to Thermal Shock EN 1367-5 Resistance to Freezing & Thawing EN 1367-1 UKAS Petrographic Examination EN 932-3 Petrographic Examination (ASR) ASTM C289-94 Sand Equivalent EN 933-8 UKAS Shape Index EN 933-4 UKAS Shale Content BGSC Report CR/03/281N Moisture Content BS 812: Part 109 Particle Density & Water Absorption EN 1097-6 UKAS Particle Density of Filler EN 1097-7 UKAS EN 13450 Particle Length of Rail Ballast Particle Size Distribution (Sieving Method) Particle Size Distribution (Sedimentation) BS 812: Part 103 Loss on Ignition Los Angeles Coefficient (LA) Los Angeles Coefficient (LA RB ) Horizontal Permeability Inc. PSD & OMC/MDD EN 933-3 EN 1097-2 EN 13286-4 EN 1744-1 EN 1744-1 ASTM C157 EN 1367-4 Immediate Bearing Index (IBI) BS EN 13286-47 Sonnenbrand Test (Visual Examination) BS EN 1367-3 UKAS UKAS

Aggregate Testing - 2017 Test Listceltest.com/pdf/Comprehensive_TestList2017.pdf · Aggregate Testing - 2017 Test List ... Aggregate Impact Value - Dry (AIV) Aggregate Impact Value

Embed Size (px)

Citation preview

Celtest Company Limited. Registered in Wales and England 1533370. Vat No. 352-5034-81

Trefelin Bangor Gwynedd LL57 4LH T +44 (0)1248 355269 F +44 (0)1248 351563 E postmaster celtest.com W www.celtest.com@

0494

Aggregate Testing - 2017 Test List

Aggregate Mechanical and Physical Testing

No. 4-8-02-1994 Appendix B

Drying Shrinkage

BS 812: Part 124

UKAS

300mm Shear Box

Apparent Bulk Density of Filler

Horizontal Permeability Inc. PSD

Alkali Reactivity - Mortar bar method (16 day)

Polished Stone Value (PSV) EN 1097-8

UKAS

BS 1377: Part 7 &SHW Volume 1 Clause 639 -

Granular MaterialCohesive Material (per loading)

BS EN 1097-3

Aggregate Abrasion Value (AAV)Aggregate Crushing Value (ACV)

Petrographic Examination Fine

BS812 - 104BS812 - 104

EN 933-5

Aggregate Impact Value - Dry (AIV)Aggregate Impact Value - Soaked (AIV)

Petrographic Examination Coarse Petrographic Examination Fine

Granular Material

ITP 1 (Based on BS812-104)

Alkali Silica Reactivity (Concrete Prism Method) BS 812: Part 123

Angle of Internal Friction & Adhesion

AccreditationDescription Method

ASTM C1260

SHW Volume 1 Clause 636 - Angle of Internal Friction & Adhesion300mm Shear Box

BS EN 1097-8: Annex ABS 812: Part 110

Constituent MaterialsDicalcium Silicate Disintegration

Compaction Fraction

Drying Shrinkage

BS EN 933-11

Iron Disintegration EN 1744-1

including Annex B

UKAS

extra over per day

Frost Susceptibility

Bond Work IndexBulk Density & Void (Loose & Compacted)

with Reinforcing Elements SuppliedCohesive Material (per loading)extra over per day

EPRI Report CS3612:FGD

BS 812: Part 112BS 812: Part 112

BS 1377: Part 7 &

UKASUKAS

EN 1097-3

UKAS

UKASUKAS

UKAS

UKAS

UKAS

EN 1097-1: Annex A

UKAS

Water Industries Spec.

Micro Deval (MDRB)

Laboratory Dry Density & Optimum Water Content

Micro Deval (Wet or Dry)

UKAS

EN 1097-2: Annex A

Flakiness Index

EN 1097-1 UKAS

UKAS

UKAS

DTP HA 41/90 UKAS

UKAS

EN 933-1

ITP 1 (Based on BS812-104)

UKAS

EN 933-10 UKASParticle Size Distribution (Air-Jet Sieving)

Petrographic Examination Coarse

in Coarse AggregatePercentage of Shells in Coarse Aggregate EN 933-7 UKAS

UKASPercentage Crushed & Broken Surfaces

Resistance to Thermal Shock EN 1367-5Resistance to Freezing & Thawing EN 1367-1 UKAS

Petrographic Examination EN 932-3

Petrographic Examination (ASR) ASTM C289-94

Sand Equivalent EN 933-8 UKASShape Index EN 933-4 UKASShale Content BGSC Report CR/03/281N

Moisture Content BS 812: Part 109Particle Density & Water Absorption EN 1097-6 UKASParticle Density of Filler EN 1097-7 UKAS

EN 13450Particle Length of Rail Ballast

Particle Size Distribution (Sieving Method)Particle Size Distribution (Sedimentation) BS 812: Part 103

Loss on Ignition

Los Angeles Coefficient (LA)

Los Angeles Coefficient (LARB)

Horizontal Permeability Inc. PSD & OMC/MDD

EN 933-3

EN 1097-2

EN 13286-4

EN 1744-1

EN 1744-1ASTM C157EN 1367-4

Immediate Bearing Index (IBI) BS EN 13286-47

Sonnenbrand Test (Visual Examination) BS EN 1367-3

UKAS

UKAS

Celtest Company Limited. Registered in Wales and England 1533370. Vat No. 352-5034-81

Trefelin Bangor Gwynedd LL57 4LH T +44 (0)1248 355269 F +44 (0)1248 351563 E postmaster celtest.com W www.celtest.com@

0494

Aggregate Testing - 2017 Test List

Aggregate Mechanical and Physical Testing (Continued…)

Hydraulically bound mixtures

Aggregate Chemical Testing

Magnesium Sulphate

Methylene Blue EN 933-9

Preparation of Eluates by Leaching Aggregatesincludes Ph and ConductivitySodium Sulphate SoundnessTotal Sulphur ContentTotal Neutralising ValueWater Soluble ChlorideWater Soluble SulphateWater Soluble Sulphate

Salt for Spreading on Highways

Cube Compressive strength Age up to 28 Days @ 40°CCube Compressive strength Age up to 28 Days BS EN 13286-41

BS EN 13286-41

Magnesium Sulphate (DWFS Specifications) DWFS (012, 013 & 049) - 1st Fraction UKAS

Cohesion EN ATS 97-1-2016 Annex C

Accelerated Swelling test BS EN 13286-49

Description

Method Accreditation

Voids Ratio EN ATS 97-1-2016 Annex F

EN 1097-5 UKASWet Attrition BS 812: 1951

Thermal Expansion (Manufacture Prisms)

Ten Per Cent Fines Value (Dry)

Sonnenbrand Test Inc. Strength Testing (AIV)Sonnenbrand Test Inc. Strength Testing (LA)

BS EN 1367-3

BS 812: Part 111 UKAS

Sonnenbrand Test (Mass Loss)

Thermal Expansion on 150mm Lump RockTen Per Cent Fines Value (Soaked) BS 812: Part 111 UKAS

Voids of Dry Compacted FillerWater Solubility EN 1744-1 UKASWater Content

UKAS

BS EN 1367-3BS EN 1367-3

BS 812-118

EN 1744-1BS 6463-102

EN 1744-1 UKAS

BS 1438 UKASEN 1744-1 UKAS

Microbial Activity Index TRL Report 54Organic Contaminators (by mortar method) EN 1744-1

Rate per additional fraction

In-House Method SO71 Based on CUR 33UKAS

UKAS

Methylene Blue (Bentonite Content)

EN 1367-2 including Annex B UKAS

EN 1367-2 Annex C UKASRate per additional fraction

Lightweight Contaminators EN 1744-1 UKAS

Magnesium Sulphate

Fulvo Acid Content EN 1744-1 UKASHumus Content EN 1744-1 UKAS

UKASUKAS

UKASCalcium Carbonate EquivalentCalcium Carbonate Reference

Carbonate Content - Volumetric Method BS 7755

BS EN 196-2BS EN 196-2

Acid Soluble Sulphides

Description Method Accreditation

Acid Soluble Chloride

BS 812: Part 119

BS EN 1744-1: Clause 13 UKAS

UKASUKAS

BS EN 1744-5: Volhard Method

Acid Soluble Sulphate

Slag Expansion BRE In-House MethodThermal Resistivity / Conductivity on Cement Bound Sand ASTM D5334

BS EN 1744-1: Clause 12

Description

UKAS

Description Method Accreditation

BS EN 13286-40

Acid Soluble Material

Soluble Sulphate Content BS 3247 UKAS

Grading of Salt BS 3247 UKASMoisture Content BS 3247

Mixing and Preparation (per mixture) BS EN 13286 UKASDirect tensile strength

Method Accreditation

Coefficient of linear expansion SHW CL 871

Chloride Content BS 3247 UKAS

Matter Insoluble in Water BS 3247 UKAS

Modulus of Elasticity (per specimen) BS EN 13286-43

EN 1744-3

UKAS

UKAS

Celtest Company Limited. Registered in Wales and England 1533370. Vat No. 352-5034-81

Trefelin Bangor Gwynedd LL57 4LH T +44 (0)1248 355269 F +44 (0)1248 351563 E postmaster celtest.com W www.celtest.com@

0494

Bituminous Testing - 2017 Test List

BS EN 12697 Series of Tests

Binder Drainage (Schellenberg Method)Binder Drainage (Basket Method)

Saturating Ageing Tensile Test BS EN 12697-45

Bituminous DesignsMethod Accreditation

Marshall Test (Stability & Flow)(loads from 1 to 25 kN)

per specimenBS EN 12697-35 UKAS

UKAS

Amount of Foreign Matter

BS EN 12697-35

UKAS

BS EN 12697-25

Hot Sand Test BS EN 12697-37 UKAS

SMA Mix Design (5 points)

Resistance to Fatigue

Indirect Tensile Strength (loads from 1 to 25 kN) per

specimenBS EN 12697-23 UKAS

Wheel Tracking (per 200mmø Core)BS EN 12697-22

BS EN 12697-3UKAS

UKAS

UKAS

BS EN 12697-32

Binder & Grading - Binder directly determined, using

bottle rotation machine, bucket centrifuge type 1 and

volume calculation

Air Voids

Bulk Density

BS EN 12697-11: Static

Binder Recovery (Rotary Evaporation)

UKAS

BS EN 12697-5 UKAS

BS EN 12697-3BS EN 1426

Laboratory Mixing per 2KG

Binder Recovery (Rotary Evaporation) / Penetration /

Softening PointUKAS

UKAS

Binder & Grading - Binder determined by difference,

using bottle rotation machine and pressure filter

BS EN 12697-1: Procedure 1 &UKASBS EN 12697-2

BS EN 12697-2

BS EN 12697-24

Resistance to de-icing fluids

AccreditationDescription Method

BS EN 1427

Maximum Density - Volumetric Procedure A

BS EN 12697-1: Procedure 1 UKAS

UKAS

Cyclic Compression - Method A

Indirect Tensile Stiffness Modulus (IT-CY) (loads from 0 to

10 kN)

Stone Mastic Asphalt Mix Design does not include

aggregate testing or additional bituminous testing.

BS EN 12697-41

Defence Works for Airfields Specification 049

BS EN 12697-43

BS 13108-5 & PD6691 Annex D UKAS

Water Sensitivity - Method A Water Sensitivity - Method B BS EN 12697-12

Resistance to Fuel

BS EN 12697-42

Permeability of Bitumen Specimen (Vertical)

Percentage Refusal Density: Per CoreBS EN 12697-9

BS EN 12697-11: Rolling Bottle

Determination of particle loss of porous asphalt BS EN 12697-17

BS 594987:2010- Annex H

Defence Works for Airfields Specification 012 UKAS

UKAS

BS EN 12697-18

UKAS

Procedure A -DryProcedure B - Dry

HRA Surface Course Design ProtocolHRA Asphalt Mix Design (loads 1 to 25 kN) does not

include aggregate testing or additional bituminous

Defence Works for Airfields Specification 013

Description

Procedure C - Sealed Specimen

BS EN 12697-8

BS EN 12697-26 Annex C UKAS

Set of 10 Specimens

UKASAffinity between aggregate & bitumen

Procedure D -Dimensions

UKAS

BS EN 12697-6:Procedure A - Dry

Permeability of Bitumen Specimen (Horizontal)BS EN 12697-19 UKAS

Procedure B - SSD

BS EN 12697-12 UKAS

UKAS

Specimen preparation by roller compactor BS EN 12697-33 UKAS

Marshall Asphalt Mix Design (loads 1 to 25 kN) does not

include aggregate testing or additional bituminous

DWFS Specification 049

Celtest Company Limited. Registered in Wales and England 1533370. Vat No. 352-5034-81

Trefelin Bangor Gwynedd LL57 4LH T +44 (0)1248 355269 F +44 (0)1248 351563 E postmaster celtest.com W www.celtest.com@

0494

Bituminous Testing - 2017 Test List

Other Bituminous Tests

Water & Binder Content of Bituminous Emulsion BS 434: Part 1 1984 Appendix F

Delta Ring & Ball BS EN 13179-1 UKAS

BBA HAPAS Appendix A.2

TPH / PAH / Phenol & Leachate

Indirect Fatigue Tensile test DD ABF: 1995

Photographs and description of asphalt Inc. PAK Marker

(per core)

Photographs and description of asphalt cores

Viscosity

Binder & Grading - Thermoplastic RoadBS 3262: Part 1: 1989

BS EN 12697-36 + In-House Method(per core)

BS EN 12697-36 + In-House Method

Bitumen Number of added Filler

Markings Inc. Glass Bead Content

Penetration Test (Bitumen)BS EN 1427: 2000

AccreditationDescription

BS EN 1426: 2000 UKASUKAS

BS 598: Part 110: 1998

BS EN 13179-2

UKAS

BS434: Part 1: 1984

Documented in house method UKAS

Water Sensitivity - Thin Surfacing Layer

BBA HAPAS Appendix A.5 2013

Softening Point

Resistance to permanent deformation

Method

Wheel Tracking (per 200mmø Core)

Resistance to permanent deformation (VRLAT) :Per Core

UKAS

Appendix G

UKAS

Sensitivity to fuelSensitivity to fuel

Based on BS DD 226: 1996(RLAT): Per Core

Torque Bond Strength

BBA HAPAS Appendix A.5 2011 UKAS

Documented in house method Based on TRL PA PA3287/97 and BS DD 226:

1996UKAS

BBA HAPAS Appendix A.3

Celtest Company Limited. Registered in Wales and England 1533370. Vat No. 352-5034-81

Trefelin Bangor Gwynedd LL57 4LH T +44 (0)1248 355269 F +44 (0)1248 351563 E postmaster celtest.com W www.celtest.com@

0494

Concrete Testing - 2017 Test List

BS 1881 Tests

BS 1881-201: BRE IP 6/81

BS EN 12390 Tests

Miscellaneous Concrete/Mortars

Method of testing Cement & Water used in Concrete

EN 196-3

BS EN 772 Masonry Tests

Strength (for water used in concrete) EN 1008/BS EN 196-1

BS EN 1008Setting Times (for water used in concrete)

Chemical Analysis

Initial Setting Time; Initial and Final Setting Time

EN 196-3

Original Mix Proportions (Screed/Mortar Mixes)

of Mortar (delivered)

Flexural & Compressive Strength

Compressive strength of Cylinders BS EN 12390-3 UKAS

EN 1008/BS EN 196-3

UKAS

BS EN 12504-1

UKAS

Documented In House Method

Accreditation

BS 4551: Part 2

EN 196-1EN 196-2

Accreditation

UKAS

UKAS

UKAS

Concrete Cubes - (delivered) per cube

Secant Modulus of Elasticity in Compression

Method

BS EN 12390-7

Accreditation

UKAS

BS EN 12390-13

Chemical Testing of water found in concrete

AccreditationDescription Method

BS EN 12390-2 and

Sulphates in Concrete

Static Modulus of Elasticity

BS EN 13892-2

Trial Mixes

Soundness

Depth of Carbonation

Cement Type (OPC, SRC or HA)

Strength

Linear Coefficient of Thermal Expansion (Concrete or

Aggregate Prism)

Description

Examining cores

BS 1881: Part 125BS 1881-121

Air Content - water column method BS EN 12350-7: Clause 4

Compressive Strength including coring

BS EN 12390-5

Flexural & Compressive Strength

Depth of penetration of water under pressure

In-house Test Method

BS EN 12504-1

UKAS

BS 1881-124

Cement Content / Original Mix Proportions

UKAS

Description Method

Resistivity BS 1881-201 UKAS

Compressive Strength -

Flexural Strength of Beams

BS 1881: Part 124Chloride Content - Titriometric method BS 1881: Part 124 UKASChloride Content - Potentiometric method BS 1881: Part 124

UKAS

Method

UKAS

Compressive Strength concrete core delivered

Description

BS EN 12504-1

of Screed (delivered)BS EN 1015-11

BS EN 12390-3

Tensile splitting strength BS EN 12390-6 UKASBS EN 12390-8

Hardened Density of Concrete

Description Method Accreditation

Compressive Strength:Air dried for 14 days BS EN 772: Clause 7.3.2

BS EN 772: Clause 7.3.5

Dried in oven for 24 hours BS EN 772: Clause 7.3.2

Oven dried @ 105oC BS EN 772: Clause 7.3.3

Oven dried @ 70oC BS EN 772: Clause 7.3.3Conditioned to 6% moisture content BS EN 772: Clause 7.3.4Conditioning by Immersion

Cellular/Hollow Units:

Net and Gross Density:

Thermal Properties (Solid Blocks Only) BS EN 1745

BS EN 772-16Solid Units:

Determination of Flatness: BS EN 772-20BS EN 772-14Moisture Movement:

Hollow/Cellular Units: BS EN 772-13Solid Units: BS EN 772-13Determination of Dimension:

Including Final Set

Setting Time :- Initial

Water Absorption by Capillary

BS EN 772-16

BS EN 722-11

Celtest Company Limited. Registered in Wales and England 1533370. Vat No. 352-5034-81

Trefelin Bangor Gwynedd LL57 4LH T +44 (0)1248 355269 F +44 (0)1248 351563 E postmaster celtest.com W www.celtest.com@

0494

Rock and Slate Testing - 2017 Test List

ISRM Rock Tests

CIRIA Rock Tests

SLATE Tests

Rock Armour Tests

Miscellaneous Rock Tests

(set of 10) 1:1 Ratio

Sulphur Dioxide Exposure

Slip Resistance using Pendulum Tester BS EN 14231

BS EN 12326-2Unpolished Slip Resistance Value

Flexural Strength under concentrated load BS EN 12372

BS EN 14157

BS EN 12371

Abrasion Resistance

BS EN 1936

Accreditation

UKAS

Point Load Index Set of 10

Water Absorption at Atmospheric pressure BS EN 13755

Frost Resistance (48 cycles)

Description Method

ISRM GuidelinesDensity ISRM Guidelines

UKAS

Real Density, Apparent Density and total Open Porosity

Brazil Tensile Strength

Porosity

Point Load Test 1 Test Only ISRM Guidelines

Deformability in Uniaxial Compression ISRM Guidelines

CIRIA Specification

CIRIA Specification

Failure Load in BendingPetrographic

Calcium Carbonate Content BS EN 12326-2

Dimensional Tolerances

BS EN 12326-2

Drop Test Breakage Index

AccreditationDescription Method

Freeze Thaw

ISRM Guidelines

Description Method

Slates with less than 20% CaCo3

CIRIA Rock manual section 3.8 Box 3.20

Wet Dynamic Crushing ValueMill Abrasion Index

Fracture Toughness CIRIA Specification

ISRM Guidelines

Accreditation

CIRIA Specification

UKAS

Unconfined Compressive Strength of

UKAS

Thermal Cycle BS EN 12326-2 UKAS

BS EN 12326-2BS EN 12326-2 UKASBS EN 12362-2

(set of 10) 1:1 Ratio - includes coring

Cerchar Abrasitivity In House Method

Accreditation

Method

BS EN 1926

Description

BS EN 13383

Accreditation

Water Absorption

Youngs Modulus ISRM Guidelines

Description

Determination of Uniaxial Compressive Strength BS EN 1926

Deformability in UCS ASTM Guidelines

Slake Durability ISRM Guidelines

Length to Thickness RatioParticle Density and Water AbsorptionDetermination of Uniaxial Compressive Strength

BS EN 13383

Rock Cores 2.5:1 Ratio

Resistance to Breakage Mass Distribution BS EN 13383

ISRM Guidelines

BS EN 1341

Non-Carbonate carbon Content BS EN 12326-2

Method

Celtest Company Limited. Registered in Wales and England 1533370. Vat No. 352-5034-81

Trefelin Bangor Gwynedd LL57 4LH T +44 (0)1248 355269 F +44 (0)1248 351563 E postmaster celtest.com W www.celtest.com@

0494

Soil Testing - 2017 Test List

BS 1377 Soil Mechanical and Physical Testing

BS 1377: Part 5: 1990

BS 1377 Soil Chemical Testing

Calcium Carbonate Content

Accreditation

Methylene Blue Value on BES In-house Method SO71: July 2009

Dry Method (Top and Bottom) UKAS

BS 1377: Part 3:1990 Clause 10 BS 1377-3: 1990

BS 1377: Part 3: 1990: Clause 3

UKASTRRL Contractor Report 54

Pulverisation BS EN 13286-48

UKAS

Saturated Moisture Content

Consolidated Drained/Undrained Triaxial

(Multistage Same Price)

BS 1377-8

BS 1377: Part 9: 1990 Clause 2.4 UKAS

AccreditationDescription Method

extra over per dayShear Vane

Method

Shear Box Interface Testing (1mm/min)ASTM D5321

extra over per day

Shear Box Interface Testing (Slow test per loading)

Resistivity

BS 1377: Part 3: 1990

PH Value BS 1377: Part 3: 1990Organic Matter Content

UKAS

UKAS

UKAS

UKAS

UKAS

UKAS

Extra charge per day for each day

Microbial Index

K.H.Head Manual of SoilFalling Head Permeability

ASTM D5321

Calculated as reciprocal of Resistivity

(3 specimens) Per specimen - up to 1 day

BS 1377: Part 2: Clause 3.3

Description

UKASUKAS

UKAS

UKAS

Accelerated Permeability in a Triaxial Cell: Environment Agency R & DUp to 4 days Technical Report P1-398/TR/2 UKAS

BS 1377: Part 2: 1990

Dispersion

UKASUp to four (4) days

UKASParticle Size Distribution (Washing and Sieving)

over four days

Laboratory Testing, Volume 2

UKAS

Open Container Method

Plasticity Index BS 1377: Part 2: 1990

Undrained Shear StrengthUndrained Triaxial (3x U38)

UKAS

Chloride Ion Content BS 1377: Part 3: 1990

Particle Size Distribution (Sedimentation) BS 1377: Part 2: 1990

BS 1377: Part 6: 1990

Shear Box - 60mm or 100mm BS 1377: Part 7:1990: Clause 4

Triaxial Permeability:

BS 1377: Part 2: 1990

BS 1377: Part 2: 1990

Electrical Conductivity of Soil

Redox Potential

BS 1377: Part 2: 1990Plastic Limit

Particle Size Distribution (Dry Sieving)

BS 1377: Part 7: 1990

Sub Clause 4:

BS 1377: Part 7: 1990

Extra Charge per day after 4 days

Particle Density - Small Pyknometer BS 1377: Part 2: 1990

Moisture Content

Pin Hole Method

UKASParticle Density - Gas Jar BS 1377: Part 2: 1990 UKAS

OMC/MDD (2.5kg, 4.5kg or

BS 1377: Part 5:1990: Clause 3

Minimum Density

UKASMCV/Moisture Content Relationship BS 1377: Part 4: 1990 Test 5.5

UKAS

MCV Single Point BS 1377: Part 4: 1990 Test 5.4

BS 1377: Part 4: Clause 7: 1990

UKASMaximum Density BS 1377: Part 4: 1990

Core Cutter Density

Wet Method Inc. Swelling

California Bearing Ratio (Laboratory)

Constant Head Permeability

Compaction Vibrating Hammer (@ NMC) BS 1377: Part 4: 1990 UKAS

Extra Charge per day after 5 days

UKAS

Dry Method (Top) UKAS

Liquid Limit - Cone Penetrometer

UKAS

BS 1377: Part 2: 1990

Initial Consumption of lime BS 1924-2

Multistage Triaxial BS 1377: Part 7: 1990 Clause 9BS 1377: Part 4: 1990

Oedometer Consolidation (up to 5 days)

BS 1377: Part 4:1990Vibrating Hammer Method

Celtest Company Limited. Registered in Wales and England 1533370. Vat No. 352-5034-81

Trefelin Bangor Gwynedd LL57 4LH T +44 (0)1248 355269 F +44 (0)1248 351563 E postmaster celtest.com W www.celtest.com@

0494

Soil Testing - 2017 Test List

BS 1377 Soil Chemical Testing (Continued…)

BS 1377: Part 3: 1990

Topsoil Analysis Topsoil AnalysisTopsoil Analysis (Contamination Assessment)Topsoil Analysis (Contamination Assessment)

Calculation only - Test 2 & 4 mustbe carried out

Miscellaneous Tests

PCM

Chromium VI

WAC (10 day t/a) BS EN 12457 Part 3

WAC including interpretation (10 day t/a) BS EN 12457 Part 3WAC  (6 day t/a) BS EN 12457 Part 3WAC including interpretation (6 day t/a) BS EN 12457 Part 3

Rates are NET and subject to VAT

Description Method Accreditation

Alkali ContentAngle of Repose (Slope Stability) In-House

Acid Soluble Sulphate

Total Petroleum Hydrocarbons (TPH'S)

Transportable Moisture Limit IMSBC CDE 2012Total Silica In-house

XRD including Pyrite

BRE Special Digest

XRD

Banded Total Petroleum Hydrocarbons (TPH'S)

Polyaromatic Hydrocarbons (Total PAH's)Speciated PAH

Total Organic Carbon

Tar Content of Asphalt Arisings (TPH C10-C40 & PAH

Speciated)In -house Standard

Sulphide and Hydrogen Sulphide Standard Text Book

GC/MS ScanHeavy Metals Suite

Full ICRCL Contamination SuiteFull ICRCL Contamination Suiteincluding EA Leachate

CLEA Suite

Electrical Conductivity of Water BS EN 27889: 1993Dangerous Substances

Calorific ValueChemical Oxides Analysis (XRF)

Asbestos Identification

Asbestos QuantificationGravimetric

Oxidisable Sulphides

Total Reduced Sulphur TRRL Report 447 Test 3

TRRL Report 447 Test 2TRRL Report 447 Test 1

Total Potential Sulphate

Water Soluble Sulphate

TRRL Report 447 Test 4

BS 1377: Part 3: 1990Gravimetric Method

Total Sulphur

Sulphate content of soil and ground water

BS 3882 (including interpretation)

BS 1377

Sulphate content of soil and ground water BS 1377: Part 3: 1990Ion exchange Method

UKAS

In House Method

AccreditationDescription Method

BS 3882BS 3882 (including interpretation)

ResistivityWenner Probe

Suspended SolidsBS 3882