A i r P u r i f i c a t i o n S y s t e m s | w w w. t r i o n i a q . c o m
Air Boss® T-SeriesElectronic Air Cleaners
www. t r ion iaq .com
Engineered Solutions For Clean AirThe TRION® T-Series is ideal for the removal of smoke,
fumes, and oil/coolant smoke and mist. The T-Series has
the ability to clean contaminated indoor air and recirculate it
back to the work area, reducing energy costs by not having
to exhaust conditioned air to the outside. Models T1300,
T2600 and T5200 can be installed either unducted or ducted
for source capture. Models T1001 and T2002 are designed
for in-ducted capture.
Features• Solid State Power Supply
• Spiked Ionizing Blades
• Extra Depth Collector Cells
• Totally Enclosed Fan Cooled Motor
• Electrical Component Box Mounted Out of Air Stream
• Optional Multi-Purpose Plenum
• Motor HP Options for Added Static Pressure
Benefits• Self Glazing Ceramic Insulators: Out of Airstream;
Impervious to Liquids; Provide Operational Longevity and Power Supply Life; Easy to Clean
• Extra Depth Collector Cell with More Dirt Holding Capacity
• Spiked Ionizer: No Ionizing Wires to Replace, Reducing Maintenance and Replacement Cost
• High Efficiency: Up to 95% on Single Pass and 99% on Double Pass Option
• Permanent Ionizer/Collector Elements: No Filter Replacement Cost; Just Wash, Dry and Reinstall
• Low Pressure Drop: Lower Energy Cost to Operate Compared to Media and Cartridge Units
• Hinged Filter Access: No Tools Required for Quick and Easy Service
2
www. t r ion iaq .com
How it WorksThe TRION® T-Series utilizes the principle of Electrostatic
Precipitation. Air is drawn by the motor/blower through a
washable metal mesh pre-filter which traps large dust particles.
The remaining particles, some as small as 0.01 microns, pass
into a strong electrical field (ionizing section) where the particulate receives an electrical charge. The charged particles then pass into
a collector plate section made up of a series of equally spaced parallel plates. Each alternate plate is charged with the same polarity
as the particles, which repel, while the interleaving plates are grounded, which attract and collect.
Air Boss® T- Series Models
Air Boss® T1001
Air Boss® T1300
Air Boss® T2002
Air Boss® T2600 Air Boss® T5200
AD
DE
D S
TATI
C P
RE
SS
UR
E (i
n. H
20)
3.0
2.0
1.0
4.0
5.0 1500RPM
0 10000 2000 3000 4000 5000 6000
800RPM700RPM600RPM
2 HP
5 HP
3 HP
2250RPM(MAX. RPM)
2000RPM
1800RPM1600RPM
1400RPM1200RPM
1000RPM800RPM
3.0
4.0
2.0
1.0
0
1 1/2 HP
3/4 HP
1 HP
CFM
3.0
2.0
1.0
02000
CFM
1400RPM
1600RPM
1800RPM
1200RPM
1000 RPM800RPM
(MAX. RPM)
3/4 HP
2 HP
1 HP
1 1/2 HP
0
500 1000 1500
1300RPM1200RPM
1100RPM
1000RPM900 RPM
1400 RPM (MAX. RPM)
0
AD
DE
D S
TATI
C P
RE
SS
UR
E (i
n. H
20)
AD
DE
D S
TATI
C P
RE
SS
UR
E (i
n. H
20)
1000 3000CFM
AD
DE
D S
TATI
C P
RE
SS
UR
E (i
n. H
20)
3.0
2.0
1.0
4.0
5.0 1500RPM
0 10000 2000 3000 4000 5000 6000
800RPM700RPM600RPM
2 HP
5 HP
3 HP
2250RPM(MAX. RPM)
2000RPM
1800RPM1600RPM
1400RPM1200RPM
1000RPM800RPM
3.0
4.0
2.0
1.0
0
1 1/2 HP
3/4 HP
1 HP
CFM
3.0
2.0
1.0
02000
CFM
1400RPM
1600RPM
1800RPM
1200RPM
1000 RPM800RPM
(MAX. RPM)
3/4 HP
2 HP
1 HP
1 1/2 HP
0
500 1000 1500
1300RPM1200RPM
1100RPM
1000RPM900 RPM
1400 RPM (MAX. RPM)
0
AD
DE
D S
TATI
C P
RE
SS
UR
E (i
n. H
20)
AD
DE
D S
TATI
C P
RE
SS
UR
E (i
n. H
20)
1000 3000CFM
T1300 Curves T2600 Curves T5200 Curves
AD
DE
D S
TATI
C P
RE
SS
UR
E (i
n. H
20)
3.0
2.0
1.0
4.0
5.0 1500RPM
0 10000 2000 3000 4000 5000 6000
800RPM700RPM600RPM
2 HP
5 HP
3 HP
2250RPM(MAX. RPM)
2000RPM
1800RPM1600RPM
1400RPM1200RPM
1000RPM800RPM
3.0
4.0
2.0
1.0
0
1 1/2 HP
3/4 HP
1 HP
CFM
3.0
2.0
1.0
02000
CFM
1400RPM
1600RPM
1800RPM
1200RPM
1000 RPM800RPM
(MAX. RPM)
3/4 HP
2 HP
1 HP
1 1/2 HP
0
500 1000 1500
1300RPM1200RPM
1100RPM
1000RPM900 RPM
1400 RPM (MAX. RPM)
0
AD
DE
D S
TATI
C P
RE
SS
UR
E (i
n. H
20)
AD
DE
D S
TATI
C P
RE
SS
UR
E (i
n. H
20)
1000 3000CFM
Pre-Filter Ionizer Collector
3
Collection Efficiencies at 0.3 Microns (Per Cell)675 CFM 825 CFM 1200 CFM 1450 CFM 1630 CFM 1875 CFM
Single Pass 95% 90% - - - -
Double Pass - 99% 95% 90% - -
Triple Pass - - 98.7% 97.5% 95% 90%
Certified Third-Party Test Data at 0.3 microns using DEHS Aerosol.
www. t r ion iaq .com
Note: Units can be stacked in configurations up to 8000 CFM.
14
498
554
TOP VIEW
470
14
28.5 Dia. Drain Location
606
Power Supply Inside
Electrical Encloser Cover
Mounting HoleLocation
.406 Dia Dimple
625
171
127
DISCHARGE END
51 51 396
533
432
FRONT VIEW
Electrical Junction Box
635
AirFlow
1.00
INTAKE END
50.8 398
432
24 Places8 Dia. Typ.
151
50.8
139.7
482
25.4
98.5
127Typ.
14
498
554
TOP VIEW
470
14
28.5 Dia. Drain Location
606
Power Supply Inside
Electrical Encloser Cover
Mounting HoleLocation
.406 Dia Dimple
625
171
127
DISCHARGE END
51 51 396
533
432
FRONT VIEW
Electrical Junction Box
635
AirFlow
1.00
INTAKE END
50.8 398
432
24 Places8 Dia. Typ.
151
50.8
139.7
482
25.4
98.5
127Typ.
14
498
554
TOP VIEW
470
14
28.5 Dia. Drain Location
606
Power Supply Inside
Electrical Encloser Cover
Mounting HoleLocation
.406 Dia Dimple
625
171
127
DISCHARGE END
51 51 396
533
432
FRONT VIEW
Electrical Junction Box
635
AirFlow
1.00
INTAKE END
50.8 398
432
24 Places8 Dia. Typ.
151
50.8
139.7
482
25.4
98.5
127Typ.
14
498
554
TOP VIEW
470
14
28.5 Dia. Drain Location
606
Power Supply Inside
Electrical Encloser Cover
Mounting HoleLocation
.406 Dia Dimple
625
171
127
DISCHARGE END
51 51 396
533
432
FRONT VIEW
Electrical Junction Box
635
AirFlow
1.00
INTAKE END
50.8 398
432
24 Places8 Dia. Typ.
151
50.8
139.7
482
25.4
98.5
127Typ.
Discharge End
Intake End
T1001 Blowerless
Dimensions 25" L x 25" W x 21" H
Installation Suspended, Wall, Frame or Duct Mounting
Unit Weight 91 Lbs., Shipping Wt. 144 Lbs.
Air Volume Single Pass: 675 - 825 CFMDouble Pass: 825 - 1,450 CFMTriple Pass: 1,450 - 1,875 CFM
Controls On/Off Switch with Indicating Light
Pre-Filter Aluminum Mesh Standard 18.4” L x 18.4” W x .88” DOptional Impinger
Primary Filter Standard Forever Filter — Electronic Ionizer / Collector Cell Optional Bag FilterOptional Absorber Module
After Filter Optional Disposable Charcoal After Filter 18.4” W x 18.4” H x .88” D
Power Supply High Frequency Solid State Design
Efficiency See chart on page 3
General Multiple Units Can be Joined Together for Increased Volume or Higher Efficiency
Standard Specifications for Each Unit
Cabinet 16 Gauge Welded Galvanized Steel
Finish Blue Epoxy Powder Coat
Air Flow Horizontal — Standard Right to Left (Left to Right Option)
Accessories Optional Source Capture Plenum Optional Brass Drain Fitting
Air Boss® T1001 SpecificationsTop View
Front View
4
www. t r ion iaq .com
Air Boss® T1300 Specifications
T1300
Dimensions 45" L x 25" W x 21" H
Installation Suspended, Wall, Frame Mounting
Unit Weight 180 Lbs., Shipping Wt. 268 Lbs.
Motor TEFC, Sealed Ball Bearings, 1725 RPM, Thermal Protected Continuous Duty, U.L. Listed
Motor Options HP Vac Hz Phase Max Amp Max Watt
Standard 3/4 120/230 60 1 11.7/6.1 950
Option 1 208/230/460 60 3 3.5/1.8 900
Blower Belt Driven, Squirrel Cage, Forward Curved, with Sealed Ball Bearings
Air Volume Single Pass: 675 - 825 CFMDouble Pass: 825 - 1,450 CFMTriple Pass: 1500 Maximum CFM
Efficiency See chart on page 3
Controls On/Off Switch with Indicating Light Motor Starter (3 Phase Only)
Sound Rating 67 dBA
Pre-Filter Standard - Aluminum Mesh 18.4” L x 18.4” W x .88” DOptional - Impinger
Primary FilterStandard Forever Filter- Electronic Ionizer / Collector CellOptional Bag FilterOptional Absorber Module
After Filter Disposable Charcoal After Filter Option 8.4” W x 18.4” H x .88” D
Power Supply High Frequency Solid State Design
Ø 28 Drain Location
Electrical Enclosure Cover Power Supply
Ø 10 Dimple Mounting Hole Location
127
625
17114 1115
14
514 470
538
Multi-directional Discharge Grille
533
106
162
84
286
16287
103
286
Electrical Junction BoxBlower Access Door
1143
AirFlow
Ø8 Dia. 12 Plcs.
2551
140
127483
25
397
432
51
98
Typ.
Typ.151
499
Ø 28 Drain Location
Electrical Enclosure Cover Power Supply
Ø 10 Dimple Mounting Hole Location
127
625
17114 1115
14
514 470
538
Multi-directional Discharge Grille
533
106
162
84
286
16287
103
286
Electrical Junction BoxBlower Access Door
1143
AirFlow
Ø8 Dia. 12 Plcs.
2551
140
127483
25
397
432
51
98
Typ.
Typ.151
499
Ø 28 Drain Location
Electrical Enclosure Cover Power Supply
Ø 10 Dimple Mounting Hole Location
127
625
17114 1115
14
514 470
538
Multi-directional Discharge Grille
533
106
162
84
286
16287
103
286
Electrical Junction BoxBlower Access Door
1143
AirFlow
Ø8 Dia. 12 Plcs.
2551
140
127483
25
397
432
51
98
Typ.
Typ.151
499
Ø 28 Drain Location
Electrical Enclosure Cover Power Supply
Ø 10 Dimple Mounting Hole Location
127
625
17114 1115
14
514 470
538
Multi-directional Discharge Grille
533
106
162
84
286
16287
103
286
Electrical Junction BoxBlower Access Door
1143
AirFlow
Ø8 Dia. 12 Plcs.
2551
140
127483
25
397
432
51
98
Typ.
Typ.151
499
Top View
Discharge End
Front View
Intake End
Standard Specifications for Each Unit
Cabinet 16 Gauge Welded Galvanized Steel
Finish Blue Epoxy Powder Coat
Air Flow Horizontal — Standard Right to Left (Left to Right Opt)
Accessories Optional Source Capture PlenumOptional Brass Drain Fitting
5
www. t r ion iaq .com
Note: Units can be stacked in configurations up to 16000 CFM.
Top View
Front View
Intake End
T2002 Blowerless
Dimensions 25" L x 43" W x 21" H
Installation Suspended, Wall, Frame Or Duct Mounting
Unit Weight 148 Lbs., Shipping Wt. 221 Lbs.
Air Volume Single Pass: 1,350 - 1,650 CFMDouble Pass: 1,650 - 2,900 CFMTriple Pass: 2,900 - 3,750 CFM
Controls On/Off Switch with Indicating Light
Pre-Filter(2) Required
Aluminum MeshStandard 18.4” L x 18.4” W x .88” DOptional Impinger
Primary Filter(2) Required
Standard Forever Filter - Electronic Ionizer/Collector CellOptional Bag Filter Optional Absorber Module
After Filter (2) Required
Optional Disposable Charcoal After Filter 18.4” W x 18.4” H x .88” D
Power Supply High Frequency Solid State Design
Efficiency See chart on page 3
General Multiple Units can be Joined Together forIncreased Volume or Higher Efficiency
Standard Specifications for Each Unit
Cabinet 16 Gauge Welded Galvanized Steel
Finish Blue Epoxy Powder Coat
Air Flow Horizontal — Standard Right to Left (Left to Right Option)
Accessories Optional Source Capture Plenum Optional Brass Drain Fitting
Air Boss® T2002 Specifications
21.82
37.75
36.63
.56
1.12 Dia. Drain Location.56 23.87
Power Supply InsideElectrical Enclosure Cover
.406 Dia. Dimple Mounting Hole Location
42.72
5.00
Junction BoxElectrical
25.00
33.752.00
2.00
21.00 17.00
Typ.
1.00
7.50
2.0033.75
17.00
32 Places.312 Dia.
2.005.50
Typ.5.00
19.00
3.871.00
6.75
Air
Flow
21.82
37.75
36.63
.56
1.12 Dia. Drain Location.56 23.87
Power Supply InsideElectrical Enclosure Cover
.406 Dia. Dimple Mounting Hole Location
42.72
5.00
Junction BoxElectrical
25.00
33.752.00
2.00
21.00 17.00
Typ.
1.00
7.50
2.0033.75
17.00
32 Places.312 Dia.
2.005.50
Typ.5.00
19.00
3.871.00
6.75
Air
Flow
21.82
37.75
36.63
.56
1.12 Dia. Drain Location.56 23.87
Power Supply InsideElectrical Enclosure Cover
.406 Dia. Dimple Mounting Hole Location
42.72
5.00
Junction BoxElectrical
25.00
33.752.00
2.00
21.00 17.00
Typ.
1.00
7.50
2.0033.75
17.00
32 Places.312 Dia.
2.005.50
Typ.5.00
19.00
3.871.00
6.75
Air
Flow
21.82
37.75
36.63
.56
1.12 Dia. Drain Location.56 23.87
Power Supply InsideElectrical Enclosure Cover
.406 Dia. Dimple Mounting Hole Location
42.72
5.00
Junction BoxElectrical
25.00
33.752.00
2.00
21.00 17.00
Typ.
1.00
7.50
2.0033.75
17.00
32 Places.312 Dia.
2.005.50
Typ.5.00
19.00
3.871.00
6.75
Air
Flow
6
Discharge End
www. t r ion iaq .com
Air Boss® T2600 Specifications
T2600
Dimensions 45" L x 43" W x 21" H
Installation Suspended, Wall, Frame Mounting
Unit Weight 180 Lbs., Shipping Wt. 268 Lbs.
Motor TEFC, Sealed Ball Bearings, 1725 RPM, Thermal Protected Continuous Duty, U.L. Listed
Motor Options HP Vac Hz Phase Amp. Max
Standard 3/4 120/230 60 1 7
Option 1 1 208/230/460 60 3 3.4/1.7
Option 2 2 208/230/460 60 3 6.4/3.2
Blower Belt Driven, Double Squirrel Cage, Forward Curved,with Sealed Ball Bearings
Air Volume Single Pass: 1,350 - 1,650 CFMDouble Pass: 1,650 - 2,900 CFMTriple Pass: 3,000 Maximum CFM
Efficiency See chart on page 3
Controls On/Off Switch with Indicating Light Motor Starter (3 Phase Only)
Sound Rating 71 DBA
Pre-Filter (2) Required
Standard Aluminum Mesh: 18.4" L x 18.4" W x .88" D Optional Impingers
Primary Filter (2) Required
Standard Forever Filter-Electronic Ionizer/Collector Cell Optional Bag Filters Optional Absorber Modules
After Filter (2) Required
Optional Disposable Charcoal After Filter 18.4” W x 18.4” H x 1” D
Power Supply High Frequency Solid State Design
Standard Specifications for Each Unit
Cabinet 16 Gauge Welded Galvanized Steel
Finish Blue Epoxy Powder Coat
Air Flow Horizontal — Standard Right to Left (Left to Right Option)
Accessories Optional Source Capture Plenum Optional Brass Drain Fitting
ØDimple Dimple Mounting Hole Location
Electrical Enclosure Cover Power Supply
127
1085
17114 1115
975930
538
14 Ø 28 Drain Location
Multi-directional Discharge Grille
533
144
162
84
286 286
99
384162
125
103
286
Electrical Junction Box
Blower Access Door
AirFlow
1143
Typ.Ø 8
16 Plcs.
51
432
191 98 25
51
14025
127
483
857
Typ.
ØDimple Dimple Mounting Hole Location
Electrical Enclosure Cover Power Supply
127
1085
17114 1115
975930
538
14 Ø 28 Drain Location
Multi-directional Discharge Grille
533
144
162
84
286 286
99
384162
125
103
286
Electrical Junction Box
Blower Access Door
AirFlow
1143
Typ.Ø 8
16 Plcs.
51
432
191 98 25
51
14025
127
483
857
Typ.
ØDimple Dimple Mounting Hole Location
Electrical Enclosure Cover Power Supply
127
1085
17114 1115
975930
538
14 Ø 28 Drain Location
Multi-directional Discharge Grille
533
144
162
84
286 286
99
384162
125
103
286
Electrical Junction Box
Blower Access Door
AirFlow
1143
Typ.Ø 8
16 Plcs.
51
432
191 98 25
51
14025
127
483
857
Typ.
ØDimple Dimple Mounting Hole Location
Electrical Enclosure Cover Power Supply
127
1085
17114 1115
975930
538
14 Ø 28 Drain Location
Multi-directional Discharge Grille
533
144
162
84
286 286
99
384162
125
103
286
Electrical Junction Box
Blower Access Door
AirFlow
1143
Typ.Ø 8
16 Plcs.
51
432
191 98 25
51
14025
127
483
857
Typ.
Top View
Discharge End
Front View
Intake End
7
www. t r ion iaq .com
Air Boss® T5200 Specifications
T5200
Dimensions 51” L x 41” W x 42” H
Installation Suspended, Wall, or Frame Mounting
Unit Weight 600 Lbs., Shipping Wt. 730 Lbs.
Motor TEFC, Sealed Ball Bearings, 1725 RPM, Thermal Protected Continuous Duty, U.L. Recognized
Motor Options HP Vac Hz Phase Max Amps Max Watts
Standard 2 230 / 460 60 3 6.8 / 3.4 1564
Option 1 3 230 / 460 60 3 9.7 / 4.0 2937
Option 2 5 230 / 460 60 3 14.7 / 7.2 4687
Blower Belt Driven, Squirrel Cage, Forward Curved, with Sealed Ball Bearings
Air Volume Single Pass: 2,700 - 3,300 CFMDouble Pass: 3,300 - 5,800 CFMTriple Pass: 6,000 Maximum CFM
Efficiency See chart on page 3
Controls On/Off Switch with Indicating Light — Motor Starter
Sound Rating 76 DBA
Pre-Filter(4) Required
Standard Aluminum Mesh 18.4” L x 18.4” W x .88” DOptional Impingers
Primary Filter(4) Required
Standard Forever Filter- Electronic Ionizer / Collector CellOptional Bag Filters Optional Absorber Modules
After Filter(4) Required
Optional Disposable Charcoal Filter18.4” L x 18.4” W x .88” D
Power Supply High Frequency Solid State Design (2 Required)
Standard Specifications for Each Unit
Cabinet 16 Gauge Welded Galvanized Steel
Finish Blue Epoxy Powder Coat
Air Flow Horizontal — Standard Right to Left (Left to Right Option)
Accessories Optional Source Capture Plenum Optional Brass Drain Fitting
714
653
930
582
Drain Hole
Ø 29
171537
Air Flow(Std.)
Electrical Connection
12577
484237
139
408
175217
149
119
1054
1295
Air Flow(Std.)
Off
On
Indicator LightsControl Switch
ComponentBox Door
BlowerAccess Cover
(Grille Location ForSide Discharge Unit)
Cell Door
1032
38 51
940
435
70
57
959
Air
Flow
127
714
653
930
582
Drain Hole
Ø 29
171537
Air Flow(Std.)
Electrical Connection
12577
484237
139
408
175217
149
119
1054
1295
Air Flow(Std.)
Off
On
Indicator LightsControl Switch
ComponentBox Door
BlowerAccess Cover
(Grille Location ForSide Discharge Unit)
Cell Door
1032
38 51
940
435
70
57
959
Air
Flow
127
714
653
930
582
Drain Hole
Ø 29
171537
Air Flow(Std.)
Electrical Connection
12577
484237
139
408
175217
149
119
1054
1295
Air Flow(Std.)
Off
On
Indicator LightsControl Switch
ComponentBox Door
BlowerAccess Cover
(Grille Location ForSide Discharge Unit)
Cell Door
1032
38 51
940
435
70
57
959
Air
Flow
127
714
653
930
582
Drain Hole
Ø 29
171537
Air Flow(Std.)
Electrical Connection
12577
484237
139
408
175217
149
119
1054
1295
Air Flow(Std.)
Off
On
Indicator LightsControl Switch
ComponentBox Door
BlowerAccess Cover
(Grille Location ForSide Discharge Unit)
Cell Door
1032
38 51
940
435
70
57
959
Air
Flow
127
Top View
Discharge End
Front View
Intake End
8
www. t r ion iaq .com
Extended Range Products
9
The Model T4002 is a duct-mounted
unit with air movement provided by an
external source, such as an exhaust fan
or air handler. The T4002 consists of
two T2002 Modules stacked vertically,
and contains four washable Ionizing/
Collecting Cells with Stainless Steel
Spiked Ionizers and Self Glazing Ceramic
Insulators. Air volume range is 3200-6400
CFM.
The Model T6002 is a duct-mounted
unit with air movement provided by an
external source, such as an exhaust
fan or air handler. The T6002 consists
of three T2002 Modules stacked
vertically, and contains six washable
Ionizing/Collecting Cells with Stainless
Steel Spiked Ionizers and Self Glazing
Ceramic Insulators. Air volume range is
4800-9600 CFM.
The Model T8002 is a duct- mounted
unit with air movement provided by an
external source, such as an exhaust fan
or air handler. The T8002 consists of four
T2002 Modules stacked vertically, and
contains eight washable Ionizing/
Collecting Cells with Stainless Steel
Spiked Ionizers and Self Glazing Ceramic
Insulators. Air volume range is 6400-
12800 CFM.
Model T4002 T6002 T8002
Dimensions (L x W x H) 25" x 42.7" x 42.3" 25" x 42.7" x 63.5" 25" x 42.7" x 84.8"
Installation In-Duct
Unit Weight 300 Lbs. 450 Lbs. 600 Lbs.
Voltage 120/60/1; 240/60/1; 460/60/3
Air Volume 3200-6400 CFM 4800-9600 CFM 6400-12800 CFM
Efficiency See chart on page 3
Controls (2) On/Off Switches with Indicating Lights
(3) On/Off Switches with Indicating Lights
(4) On/Off Switches with Indicating Lights
Power Supply (2) High Frequency, Solid State (3) High Frequency, Solid State (4) High Frequency, Solid State
1" Mesh Prefilter - Qty. 4 6 8
Ionizing/Collecting Cell - Qty. 4 6 8
After Filter (Option) - Qty. 1" Charcoal After Filter (4) Required1" Mesh Filter (4) Required
1" Charcoal After Filter (6) Required1" Mesh Filter (6) Required
1" Charcoal After Filter (6) Required 1" Mesh Filter (8) Required
T4002 T6002 T8002
Standard Specifications for Each Unit
Cabinet 16 Gauge Welded Galvanized Steel
Finish Blue Epoxy Powder Coat
Air Flow Horizontal — Standard Right to Left (Left to Right Option)
Accessories Brass Drain Fittings; Drain Trays between Modules; Refillable Carbon Modules for Odor Control
Note: T2002 Modules can be stacked up to 5-high and 2-wide for 32000 CFM.
LIMITED
3 Our Electronic Air Cleaners come with a three-year limited warranty.
Mini M.E. Mist CollectorAir Boss MP600M
Learn more about other
TRION® industrial products
by contacting your local
TRION representative or by
visiting us on the web at
www.tr ioniaq.com.
T-TSERIES-0518
Proudly Designed, Engineered, and
Manufactured in the USA.*
TRION® is a registered trademark of Air System Components, Inc. Air System Components, Inc. is a subsidiary of Johnson Controls Inc. All product specifications reflect available information at the printing of this brochure. TRION® reserves the right to revise or modify products and/or specifications without notice. © 2018 TRION®
TRION® 101 McNeill RoadSanford, NC 27330 [email protected]
To help serve you better, please contact us at:
800-458-2379 (fax)
800-884-0002 (tel)
*Manufactured with domestic and foreign components.
Industry Membership:
Indoor Air Quality Since 1947
ISO 9001:2015 Certified