W/ GABLE END ISOMETRIC VIEW SINGLE PITCH C.H.M. DRAWN BY: K.A.M. CHECKED BY: DATE - ISSUE: SHEET: SCALE: STANDARD SYSTEM DETAILS PLEASE NOTE ALL DETAILS AS SHOWN ARE FOR REFERENCE ONLY AND SUBJECT TO CHANGE PER ACURLITE PROJECT PROPOSAL, SPECIFIC SITE CONDITIONS, ACURLITE P.E. ANALYSIS, AND GOVERNING CODE REQUIREMENTS. 11/30/17 - A 570.759.6882 www.acurlite.com [email protected] NOV 30, 2017 SAMPLE N.T.S.

ALL DETAILS AS SHOWN ARE FOR REFERENCE ONLY AND … · 2020-02-13 · w/ gable end isometric view single pitch c.h.m. drawn by: k.a.m. checked by: date - issue: sheet: scale: standard

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ALL DETAILS AS SHOWN ARE FOR REFERENCE ONLY AND … · 2020-02-13 · w/ gable end isometric view single pitch c.h.m. drawn by: k.a.m. checked by: date - issue: sheet: scale: standard

W/ GABLE ENDISOMETRIC VIEW

SINGLE PITCHC.H.M.

DRAWN BY:

K.A.M.CHECKED BY:

DATE - ISSUE:

SHEET:

SCALE:

STANDARDSYSTEMDETAILS

PLE

ASE

NO

TEA

LL D

ETA

ILS

AS

SHO

WN

ARE

FO

R RE

FERE

NC

EO

NLY

AN

D S

UBJE

CT

TO C

HAN

GE

PER

AC

URLI

TE P

ROJE

CT

PRO

POSA

L, S

PEC

IFIC

SITE

CO

ND

ITIO

NS,

AC

URLI

TE P

.E. A

NA

LYSI

S, A

ND

GO

VER

NIN

G C

OD

E RE

QUI

REM

ENTS

.

11/30/17 - A

© 570.

759.

6882

w

ww

.acu

rlit

e.co

m

sale

s@ac

urlit

e.co

m

NO

V 3

0, 2

017

SAMPLE

N.T.S.

Page 2: ALL DETAILS AS SHOWN ARE FOR REFERENCE ONLY AND … · 2020-02-13 · w/ gable end isometric view single pitch c.h.m. drawn by: k.a.m. checked by: date - issue: sheet: scale: standard

INSULATED CLOSURE - FOR ADDITIONAL COST(Factory Assembly Includes Rigid Insulation & Formed Backer)

ALUM. GLASS REST & SILICONE SETTING BLOCK(Located At Quarter Points - 2 Per Bay)

SILICONE GASKET

BACKER ROD & CONTINUOUS SEAL

EXTRUDED ALUMINUM PURLIN(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)

FASTEN PURLIN ASSEMBLY TO RAFTER

EXTRUDED ALUMINUM RAFTER(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)

TYPICAL DETAIL

CURB MUST RESIST ALL LOADS/REACTIONSIMPOSED BY SKYLIGHT

(Reactions Provided By Acurlite P.E.)(Responsible E.O.R. to Verify and Approve)

SILL LUG(Lug Size, Type & Locations Per Acurlite P.E. Analysis)

30.26°712

D1

INSTALLATION

FASTEN PRESSURE CAP TO RAFTER & APPLY SEAL

EXTRUDED ALUM. COVER CAP & PRESSURE CAP W/ GASKET

INSTALL GLAZING PER INDUSTRY STANDARDS(Follow GANA Guidelines & Acurlite Installation Manual)

INSULATED LAMINATED / LAMINATED GLAZINGINCLUDES ALL BACKER ROD & GLAZING SEALANTS

(Max Unit Size & Required Thickness - Per AAMA Guidelines)(Glazing Calculations Provided For Additional Cost)

ISOLATION/WATERPROOF MEMBRANE(Not By Acurlite - Provided By Others)

FASTEN RAFTER ASSEMBLY TO LUGS - IF REQ.

FULL BEARING SHIM - IF REQUIRED(1/4" Max. Shim Space Typical - Unless Noted Otherwise)(Not by Acurlite - Provided By Others)

MINERAL WOOL TO FILL VOIDS - FOR ADDITIONAL COST(Standard Batt Type - Installer To Ensure System Weep Path Is NOT Blocked)

FASTEN SILL LUG TO CURB(Seal In & Around Lug & Fastener)

INSTALL SILL PAN IN BED OF SEALANT

SPONGE GASKET - FACTORY APPLIED TO SILL PAN(3/4" Void At System Weep As Required)

FORMED EXTERIOR CLOSURE - 1/16" ALUM. STANDARD(Consult Factory For Optional Thickness & Materials)

(Typical Splice Shown As Dashed Line - Locate As Required)

SILL

DETAILS AS SHOWN ARE TYPICAL & FOR REFERENCE(Consult Factory for Additional Modification & Performance Improvements)

CURB SHOULD BE PLUMB, LEVEL & SQUAREPER INDUSTRY STANDARD TOLERANCES

(Max Allowed ±1/8" PER 12' - 0" - Unless Noted Otherwise)(Not By Acurlite - Provided By Others)

PLEASE NOTE

ALL ROOFING, TERMINATION BARS, REGLETS,COUNTER FLASHINGS & FLASHINGS NOT

INTEGRAL TO SKYLIGHT SYSTEM FUNCTION(Not By Acurlite - Provided By Others)

STRUCTURAL SEAL FLANGE - IF REQUIRED(Factory Applied To Purlin - 1/4-20 x 3/4" Flat Head Screw)

DETAILS / MATERIALS PER CONTRACT DOCUMENTS(Not By Acurlite - Provided By Others)

FORMED SILL PAN - 1/16" ALUM. STANDARD(Consult Factory For Optional Thickness & Materials)

APPLY CONT. STRUCTURAL SEAL - IF REQUIRED

PROPER SUBSTRATE REQUIRED FOR ATTACHMENT(Not By Acurlite - Provided By Others)

FASTEN EXTERIOR CLOSURE TO SILL PAN(Use #10 x 1/2" Pan Head S.M.S. - Locate 12" O.C. Typical)

FASTEN EXTERIOR CLOSURE TO PURLIN / FLANGE

USE SPECIFIED DOW CORNING SILICONE(Per Acurlite P.E. Analysis & Installation Manual)

FASTENERS PROVIDED BY ACURLITE(Fastener Size & Type Per Acurlite P.E. Analysis Unless Noted)

OPTIONS FOR THERMAL ENHANCEMENT

SNAP ON COVER CAP(Not Required For Water Tightness)

CURB / SUBSTRUCTURE BY OTHERS

STANDARD & CUSTOM FINISHES(Paint, Anodize & Powder Coat Available)

SHADES/LOUVERS - PANELS - BIPV/DYNAMIC GLAZING(Consult Factory For Your Project Specific Requirements)

OPTIONS FOR VISUAL ENHANCEMENT

VARIABLE SLOPE - ALL PITCHES AVAILABLE(Consult Factory - Based On Project Specific Conditions)

C.H.M.

DRAWN BY:

K.A.M.CHECKED BY:

DATE - ISSUE:

SHEET:

SCALE:

STANDARDSYSTEMDETAILS

PLE

ASE

NO

TEA

LL D

ETA

ILS

AS

SHO

WN

ARE

FO

R RE

FERE

NC

EO

NLY

AN

D S

UBJE

CT

TO C

HAN

GE

PER

AC

URLI

TE P

ROJE

CT

PRO

POSA

L, S

PEC

IFIC

SITE

CO

ND

ITIO

NS,

AC

URLI

TE P

.E. A

NA

LYSI

S, A

ND

GO

VER

NIN

G C

OD

E RE

QUI

REM

ENTS

.

11/30/17 - A

© 570.

759.

6882

w

ww

.acu

rlit

e.co

m

sale

s@ac

urlit

e.co

m

NO

V 3

0, 2

017

D1

6" = 1' - 0"

Page 3: ALL DETAILS AS SHOWN ARE FOR REFERENCE ONLY AND … · 2020-02-13 · w/ gable end isometric view single pitch c.h.m. drawn by: k.a.m. checked by: date - issue: sheet: scale: standard

BACKER ROD & CONTINUOUS SEAL

FASTENERS PROVIDED BY ACURLITE(Fastener Size & Type Per Acurlite P.E. Analysis Unless Noted)

OPTIONS FOR VISUAL ENHANCEMENT

FASTEN PURLIN ASSEMBLY TO RAFTER

USE SPECIFIED DOW CORNING SILICONE(Per Acurlite P.E. Analysis & Installation Manual)30.26°7

12

INSTALLATION

APPLY CONT. STRUCTURAL SEAL - IF REQUIRED

INSULATED LAMINATED / LAMINATED GLAZINGINCLUDES ALL BACKER ROD & GLAZING SEALANTS

(Max Unit Size & Required Thickness - Per AAMA Guidelines)(Glazing Calculations Can Be Provided For Additional Cost)

SHADES/LOUVERS - PANELS - BIPV/DYNAMIC GLAZING(Consult Factory For Your Project Specific Requirements)

STANDARD & CUSTOM FINISHES(Paint, Anodize & Powder Coat Available)

EXTRUDED ALUM. PURLIN(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)

SILICONE GASKET

ALUM. GLASS REST & SILICONE SETTING BLOCK(Located At Quarter Points - 2 Per Bay)

EXTRUDED ALUM. RAFTER(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)

INSTALL GLAZING PER INDUSTRY STANDARDS(Follow GANA Guidelines & Acurlite Installation Manual)

STRUCTURAL SEAL FLANGE FASTENED TO PURLIN(Factory Applied To Purlin - 1/4-20 x 3/4" Flat Head Screw)

VARIABLE SLOPE - ALL PITCHES AVAILABLE(Consult Factory - Based On Project Specific Conditions)

FASTEN PRESSURE CAP TO RAFTER & APPLY SEAL

SNAP ON COVER CAP(Not Required For Water Tightness)

PURLINTYPICAL DETAIL

D2 C.H.M.

DRAWN BY:

K.A.M.CHECKED BY:

DATE - ISSUE:

SHEET:

SCALE:

STANDARDSYSTEMDETAILS

PLE

ASE

NO

TEA

LL D

ETA

ILS

AS

SHO

WN

ARE

FO

R RE

FERE

NC

EO

NLY

AN

D S

UBJE

CT

TO C

HAN

GE

PER

AC

URLI

TE P

ROJE

CT

PRO

POSA

L, S

PEC

IFIC

SITE

CO

ND

ITIO

NS,

AC

URLI

TE P

.E. A

NA

LYSI

S, A

ND

GO

VER

NIN

G C

OD

E RE

QUI

REM

ENTS

.

11/30/17 - A

© 570.

759.

6882

w

ww

.acu

rlit

e.co

m

sale

s@ac

urlit

e.co

m

NO

V 3

0, 2

017

D2

6" = 1' - 0"

Page 4: ALL DETAILS AS SHOWN ARE FOR REFERENCE ONLY AND … · 2020-02-13 · w/ gable end isometric view single pitch c.h.m. drawn by: k.a.m. checked by: date - issue: sheet: scale: standard

TYPICAL DETAILHEAD

D3

FULL BEARING SHIM AS REQUIRED(1/4" Max. Shim Space Typical - Unless Noted Otherwise)(Not by Acurlite - Provided By Others)

FASTEN LUG TO CURB

INSTALL RIDGE PLATE

FASTEN PURLIN ASSEMBLY TO RAFTER

FASTEN EXTERIOR CLOSURE TO PURLIN / FLANGEAPPLY CONT. STRUCTURAL SEAL - IF REQUIRED

FASTENERS PROVIDED BY ACURLITE(Fastener Size & Type Per Acurlite P.E. Analysis Unless Noted)

USE SPECIFIED DOW CORNING SILICONE(Per Acurlite P.E. Analysis & Installation Manual)

SNAP ON COVER CAP(Not Required For Water Tightness)

INSTALL GLAZING PER INDUSTRY STANDARDS(Follow GANA Guidelines & Acurlite Installation Manual)

PROPER SUBSTRATE REQUIRED FOR ATTACHMENT(Not By Acurlite - Provided By Others)

DETAILS / MATERIALS PER CONTRACT DOCUMENTS(Not By Acurlite - Provided By Others)

CURB / SUBSTRUCTURE BY OTHERS

FASTEN RAFTER ASSEMBLY TO LUGS - IF REQ.

BACKER ROD & CONTINUOUS SEAL

INSTALLATION

FASTEN PRESSURE CAP TO RAFTER & APPLY SEAL

ISOLATION/WATERPROOF MEMBRANE(Not By Acurlite - Provided By Others)

MINERAL WOOL TO FILL VOIDS - FOR ADDITIONAL COST(Standard Batt Type - Installer To Ensure System Weep Path Is NOT Blocked)

OPTIONS FOR THERMAL ENHANCEMENT

INSULATED LAMINATED / LAMINATED GLAZINGINCLUDES ALL BACKER ROD & GLAZING SEALANTS

(Max Unit Size & Required Thickness - Per AAMA Guidelines)(Glazing Calculations Provided For Additional Cost)

DETAILS AS SHOWN ARE TYPICAL & FOR REFERENCE(Consult Factory for Additional Modification & Performance Improvements)

STANDARD & CUSTOM FINISHES(Paint, Anodize & Powder Coat Available)

OPTIONS FOR VISUAL ENHANCEMENT

SHADES/LOUVERS - PANELS - BIPV/DYNAMIC GLAZING(Consult Factory For Your Project Specific Requirements)

VARIABLE SLOPE - ALL PITCHES AVAILABLE(Consult Factory - Based On Project Specific Conditions)

FASTEN EXTERIOR CLOSURE TO CURB(Shim & Seal As Required)

COUNTER FLASHING & REGLETS(Not By Acurlite - Provided By Others)

SILICONE GASKET

EXTRUDED ALUMINUM PURLIN(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)

EXTRUDED ALUMINUM RAFTER(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)

STRUCTURAL SEAL FLANGE - IF REQUIRED(Factory Applied To Purlin - 1/4-20 x 3/4" Flat Head Screw)

EXTRUDED ALUM. COVER CAP & PRESSURE CAP W/ GASKET

30.26°712

LAP MEMBRANE INTO SYSTEM(Not By Acurlite - Provided By Others)

CURB SHOULD BE PLUMB, LEVEL & SQUAREPER INDUSTRY STANDARD TOLERANCES

(Max Allowed ±1/8" PER 12' - 0" - Unless Noted Otherwise)(Not By Acurlite - Provided By Others)

CURB MUST RESIST ALL LOADS/REACTIONSIMPOSED BY SKYLIGHT

(Reactions Provided By Acurlite P.E.)(Responsible E.O.R. to Verify and Approve)

PLEASE NOTE

ALL ROOFING, TERMINATION BARS, REGLETS,COUNTER FLASHINGS & FLASHINGS NOT

INTEGRAL TO SKYLIGHT SYSTEM FUNCTION(Not By Acurlite - Provided By Others)

FORMED EXTERIOR CLOSURE - 1/16" ALUM. STANDARD(Consult Factory For Optional Thickness & Materials)

(Typical Splice Shown As Dashed Line - Locate As Required)

FORMED INTERIOR CLOSURE - 1/16" ALUM. STANDARDOPTIONAL - IF REQUIRED / INCLUDED(Consult Factory For Optional Thickness & Materials)

FORMED RIDGE PLATE - 1/16" ALUM. STANDARD(Consult Factory For Optional Thickness & Materials)

RIDGE LUG(Lug Size, Type & Locations Per Acurlite P.E. Analysis)

FASTEN INTERIOR CLOSURE - 1/16" ALUM. STANDARDBETWEEN RAFTERS - IF REQUIRED / INCLUDED(Consult Factory For Optional Thickness & Materials)(Use Pop Rivets As Required)

C.H.M.

DRAWN BY:

K.A.M.CHECKED BY:

DATE - ISSUE:

SHEET:

SCALE:

STANDARDSYSTEMDETAILS

PLE

ASE

NO

TEA

LL D

ETA

ILS

AS

SHO

WN

ARE

FO

R RE

FERE

NC

EO

NLY

AN

D S

UBJE

CT

TO C

HAN

GE

PER

AC

URLI

TE P

ROJE

CT

PRO

POSA

L, S

PEC

IFIC

SITE

CO

ND

ITIO

NS,

AC

URLI

TE P

.E. A

NA

LYSI

S, A

ND

GO

VER

NIN

G C

OD

E RE

QUI

REM

ENTS

.

11/30/17 - A

© 570.

759.

6882

w

ww

.acu

rlit

e.co

m

sale

s@ac

urlit

e.co

m

NO

V 3

0, 2

017

D3

6" = 1' - 0"

Page 5: ALL DETAILS AS SHOWN ARE FOR REFERENCE ONLY AND … · 2020-02-13 · w/ gable end isometric view single pitch c.h.m. drawn by: k.a.m. checked by: date - issue: sheet: scale: standard

TYPICAL DETAILJAMB

D4

CURB SHOULD BE PLUMB, LEVEL & SQUAREPER INDUSTRY STANDARD TOLERANCES

(Max Allowed ±1/8" PER 12' - 0" - Unless Noted Otherwise)(Not By Acurlite - Provided By Others)

CURB MUST RESIST ALL LOADS/REACTIONSIMPOSED BY SKYLIGHT

(Reactions Provided By Acurlite P.E.)(Responsible E.O.R. to Verify and Approve)

PLEASE NOTE

ALL ROOFING, TERMINATION BARS, REGLETS,COUNTER FLASHINGS & FLASHINGS NOT

INTEGRAL TO SKYLIGHT SYSTEM FUNCTION(Not By Acurlite - Provided By Others)

SILICONE GASKETEXTRUDED ALUM. PURLIN(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)

EXTRUDED ALUM. RAFTER(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)

INSULATED LAMINATED / LAMINATED GLAZINGINCLUDES ALL BACKER ROD & GLAZING SEALANTS(Max Unit Size & Required Thickness - Per AAMA Guidelines)(Glazing Calculations Can Be Provided For Additional Cost)

STANDARD & CUSTOM FINISHES(Paint, Anodize & Powder Coat Available)

OPTIONS FOR VISUAL ENHANCEMENT

SHADES/LOUVERS - PANELS - BIPV/DYNAMIC GLAZING(Consult Factory for your project specific needs)

EXTRUDED ALUM. COVER CAP& PRESSURE CAP W/ GASKET

VARIABLE SLOPE - ALL PITCHES AVAILABLE(Consult Factory - Based On Project Specific Conditions)

CURB / SUBSTRUCTURE BY OTHERS

ISOLATION/WATERPROOF MEMBRANE(Not By Acurlite - Provided By Others)

DETAILS / MATERIALS PER CONTRACT DOCUMENTS(Not By Acurlite - Provided By Others)

PROPER SUBSTRATE REQUIRED FOR ATTACHMENT(Not By Acurlite - Provided By Others)

COUNTER FLASHING & REGLETS(Not By Acurlite - Provided By Others)

USE SPECIFIED DOW CORNING SILICONE(Per Acurlite P.E. Analysis & Installation Manual)

FASTENERS PROVIDED BY ACURLITE(Fastener Size & Type Per Acurlite P.E. Analysis Unless Noted)

SNAP ON COVER CAP(Not Required For Water Tightness)

INSTALL GLAZING PER INDUSTRY STANDARDS(Follow GANA Guidelines & Acurlite Installation Manual)

FASTEN PRESSURE CAP TO RAFTER & APPLY SEAL

FASTEN EXTERIOR CLOSURE TO CURB(Shim & Seal As Required)

INSTALLATION

LAP MEMBRANE INTO SYSTEM(Not By Acurlite - Provided By Others)

FORMED EXTERIOR CLOSURE - 1/16" ALUM. STANDARD(Consult Factory For Optional Thickness & Materials)(Typical Splice Shown As Dashed Line - Locate As Required)

FASTEN EXTERIOR CLOSURE TO ANGLE SPACER(Not By Acurlite - Provided By Others)

FORMED ANGLE SPACER - 1/16" ALUM. STANDARD(Consult Factory For Optional Thickness & Materials)(Factory Applied To Rafter)

FASTEN PURLIN ASSEMBLY TO RAFTERBACKER ROD & CONTINUOUS SEAL

C.H.M.

DRAWN BY:

K.A.M.CHECKED BY:

DATE - ISSUE:

SHEET:

SCALE:

STANDARDSYSTEMDETAILS

PLE

ASE

NO

TEA

LL D

ETA

ILS

AS

SHO

WN

ARE

FO

R RE

FERE

NC

EO

NLY

AN

D S

UBJE

CT

TO C

HAN

GE

PER

AC

URLI

TE P

ROJE

CT

PRO

POSA

L, S

PEC

IFIC

SITE

CO

ND

ITIO

NS,

AC

URLI

TE P

.E. A

NA

LYSI

S, A

ND

GO

VER

NIN

G C

OD

E RE

QUI

REM

ENTS

.

11/30/17 - A

© 570.

759.

6882

w

ww

.acu

rlit

e.co

m

sale

s@ac

urlit

e.co

m

NO

V 3

0, 2

017

D4

6" = 1' - 0"

Page 6: ALL DETAILS AS SHOWN ARE FOR REFERENCE ONLY AND … · 2020-02-13 · w/ gable end isometric view single pitch c.h.m. drawn by: k.a.m. checked by: date - issue: sheet: scale: standard

FASTEN PURLIN ASSEMBLY TO RAFTER

INSTALLATION

USE SPECIFIED DOW CORNING SILICONE(Per Acurlite P.E. Analysis & Installation Manual)

FASTENERS PROVIDED BY ACURLITE(Fastener Size & Type Per Acurlite P.E. Analysis Unless Noted)

SILICONE GASKET

FASTEN PRESSURE CAP TO RAFTER & APPLY SEAL

EXTRUDED ALUM. RAFTER(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)

EXTRUDED ALUM. PURLIN(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)

INSULATED LAMINATED / LAMINATED GLAZINGINCLUDES ALL BACKER ROD & GLAZING SEALANTS

(Max Unit Size & Required Thickness - Per AAMA Guidelines)(Glazing Calculations Can Be Provided For Additional Cost)

STANDARD & CUSTOM FINISHES(Paint, Anodize & Powder Coat Available)

OPTIONS FOR VISUAL ENHANCEMENT

EXTRUDED ALUM. COVER CAP& PRESSURE CAP W/ GASKET

SHADES/LOUVERS - PANELS - BIPV/DYNAMIC GLAZING(Consult Factory for your project specific needs)

INSTALL GLAZING PER INDUSTRY STANDARDS(Follow GANA Guidelines & Acurlite Installation Manual)

SNAP ON COVER CAP(Not Required for Water tightness)

VARIABLE SLOPE - ALL PITCHES AVAILABLE(Consult Factory - Based On Project Specific Conditions)

RAFTERD5

TYPICAL DETAIL

C.H.M.

DRAWN BY:

K.A.M.CHECKED BY:

DATE - ISSUE:

SHEET:

SCALE:

STANDARDSYSTEMDETAILS

PLE

ASE

NO

TEA

LL D

ETA

ILS

AS

SHO

WN

ARE

FO

R RE

FERE

NC

EO

NLY

AN

D S

UBJE

CT

TO C

HAN

GE

PER

AC

URLI

TE P

ROJE

CT

PRO

POSA

L, S

PEC

IFIC

SITE

CO

ND

ITIO

NS,

AC

URLI

TE P

.E. A

NA

LYSI

S, A

ND

GO

VER

NIN

G C

OD

E RE

QUI

REM

ENTS

.

11/30/17 - A

© 570.

759.

6882

w

ww

.acu

rlit

e.co

m

sale

s@ac

urlit

e.co

m

NO

V 3

0, 2

017

D5

6" = 1' - 0"

Page 7: ALL DETAILS AS SHOWN ARE FOR REFERENCE ONLY AND … · 2020-02-13 · w/ gable end isometric view single pitch c.h.m. drawn by: k.a.m. checked by: date - issue: sheet: scale: standard

GABLE HEADD6

TYPICAL DETAIL

SILICONE GASKETEXTRUDED ALUM. PURLIN

(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)

EXTRUDED ALUM. RAFTER(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)

INSULATED LAMINATED / LAMINATED GLAZINGINCLUDES ALL BACKER ROD & GLAZING SEALANTS

(Max Unit Size & Required Thickness - Per AAMA Guidelines)(Glazing Calculations Can Be Provided For Additional Cost)

STANDARD & CUSTOM FINISHES(Paint, Anodize & Powder Coat Available)

OPTIONS FOR VISUAL ENHANCEMENT

SHADES/LOUVERS - PANELS - BIPV/DYNAMIC GLAZING(Consult Factory for your project specific needs)

EXTRUDED ALUM. COVER CAP& PRESSURE CAP W/ GASKET

VARIABLE SLOPE - ALL PITCHES AVAILABLE(Consult Factory - Based On Project Specific Conditions)

MINERAL WOOL TO FILL VOIDS - FOR ADDITIONAL COST(Standard Batt Type - Installer To Ensure System Weep Path Is NOT Blocked)

INSULATED CLOSURE - FOR ADDITIONAL COST(Factory Assembly Includes Rigid Insulation & Formed Alum. Backer)

DETAILS AS SHOWN ARE TYPICAL & FOR REFERENCE(Consult Factory for Additional Modification & Performance Improvements)

OPTIONS FOR THERMAL ENHANCEMENT

FASTEN HEAD LUG TO RAFTER(Seal In & Around Lug & Fastener)

FASTEN EXTERIOR CLOSURE TO PURLIN / FLANGE

FORMED EXTERIOR CLOSURE - 1/16" ALUM. STANDARD(Consult Factory For Optional Thickness & Materials)

(Typical Splice Shown As Dashed Line - Locate As Required)

INSTALLATION

USE SPECIFIED DOW CORNING SILICONE(Per Acurlite P.E. Analysis & Installation Manual)

INSTALL GLAZING PER INDUSTRY STANDARDS(Follow GANA Guidelines & Acurlite Installation Manual)

GABLE HEAD LUG(Lug Size, Type & Locations Per Acurlite P.E. Analysis)

FASTEN RAFTER ASSEMBLY TO LUGS - IF REQ.

FASTEN PURLIN ASSEMBLY TO RAFTER

FASTEN PRESSURE CAP TO RAFTER & APPLY SEAL

SNAP ON COVER CAP(Not Required For Water Tightness)

FASTENERS PROVIDED BY ACURLITE(Fastener Size & Type Per Acurlite P.E. Analysis Unless Noted)

C.H.M.

DRAWN BY:

K.A.M.CHECKED BY:

DATE - ISSUE:

SHEET:

SCALE:

STANDARDSYSTEMDETAILS

PLE

ASE

NO

TEA

LL D

ETA

ILS

AS

SHO

WN

ARE

FO

R RE

FERE

NC

EO

NLY

AN

D S

UBJE

CT

TO C

HAN

GE

PER

AC

URLI

TE P

ROJE

CT

PRO

POSA

L, S

PEC

IFIC

SITE

CO

ND

ITIO

NS,

AC

URLI

TE P

.E. A

NA

LYSI

S, A

ND

GO

VER

NIN

G C

OD

E RE

QUI

REM

ENTS

.

11/30/17 - A

© 570.

759.

6882

w

ww

.acu

rlit

e.co

m

sale

s@ac

urlit

e.co

m

NO

V 3

0, 2

017

D6

6" = 1' - 0"

Page 8: ALL DETAILS AS SHOWN ARE FOR REFERENCE ONLY AND … · 2020-02-13 · w/ gable end isometric view single pitch c.h.m. drawn by: k.a.m. checked by: date - issue: sheet: scale: standard

TYPICAL DETAILGABLE SILL

D7

CURB SHOULD BE PLUMB, LEVEL & SQUAREPER INDUSTRY STANDARD TOLERANCES

(Max Allowed ±1/8" PER 12' - 0" - Unless Noted Otherwise)(Not By Acurlite - Provided By Others)

CURB MUST RESIST ALL LOADS/REACTIONSIMPOSED BY SKYLIGHT

(Reactions Provided By Acurlite P.E.)(Responsible E.O.R. to Verify and Approve)

PLEASE NOTE

ALL ROOFING, TERMINATION BARS, REGLETS,COUNTER FLASHINGS & FLASHINGS NOT

INTEGRAL TO SKYLIGHT SYSTEM FUNCTION(Not By Acurlite - Provided By Others)

ISOLATION/WATERPROOF MEMBRANE(Not By Acurlite - Provided By Others)

PROPER SUBSTRATE REQUIRED FOR ATTACHMENT(Not By Acurlite - Provided By Others)

DETAILS / MATERIALS PER CONTRACT DOCUMENTS(Not By Acurlite - Provided By Others)

CURB / SUBSTRUCTURE BY OTHERS

FORMED EXTERIOR CLOSURE - 1/16" ALUM. STANDARD(Consult Factory For Optional Thickness & Materials)(Typical Splice Shown As Dashed Line - Locate As Required)

SILL LUG(Lug Size, Type & Locations Per Acurlite P.E. Analysis)

STANDARD & CUSTOM FINISHES(Paint, Anodize & Powder Coat Available)

SPONGE GASKET - FACTORY APPLIED TO SILL PAN(3/4" Void At System Weep As Required)

INSULATED LAMINATED / LAMINATED GLAZINGINCLUDES ALL BACKER ROD & GLAZING SEALANTS(Max Unit Size & Required Thickness - Per AAMA Guidelines)(Glazing Calculations Can Be Provided For Additional Cost)

EXTRUDED ALUM. PURLIN(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)

SILICONE GASKET

FORMED ANGLE SPACER - 1/16" ALUM. STANDARD(Consult Factory For Optional Thickness & Materials)(Factory Applied To Purlin)

SHADES/LOUVERS - PANELS - BIPV/DYNAMIC GLAZING(Consult Factory for your project specific needs)

EXTRUDED ALUM. COVER CAP& PRESSURE CAP W/ GASKET

FORMED SILL PAN - 1/16" ALUM. STANDARD(Consult Factory For Optional Thickness & Materials)

ALUM. GLASS REST & SILICONE SETTING BLOCK(Located At Quarter Points - 2 Per Bay)

EXTRUDED ALUM. RAFTER(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)

OPTIONS FOR VISUAL ENHANCEMENT

VARIABLE SLOPE - ALL PITCHES AVAILABLE(Consult Factory - Based On Project Specific Conditions)

FULL BEARING SHIM - IF REQUIRED(1/4" Max. Shim Space Typical - Unless Noted Otherwise)

(Not by Acurlite - Provided By Others)

INSTALLATION

INSTALL GLAZING PER INDUSTRY STANDARDS(Follow GANA Guidelines & Acurlite Installation Manual)

FASTEN PURLIN ASSEMBLY TO RAFTER

FASTEN PRESSURE CAP TO RAFTER & APPLY SEAL

FASTEN RAFTER ASSEMBLY TO LUGS - IF REQ.

INSTALL SILL PAN IN BED OF SEALANT

FASTEN SILL LUG TO CURB(Seal In & Around Lug & Fastener)

FASTEN EXTERIOR CLOSURE TO SILL PAN(Use #10 x 1/2" Pan Head S.M.S. - Locate 12" O.C. Typical)

FASTEN EXTERIOR CLOSURE TO ANGLE SPACER(Use Pop Rivets As Required)

FASTENERS PROVIDED BY ACURLITE(Fastener Size & Type Per Acurlite P.E. Analysis Unless Noted)

USE SPECIFIED DOW CORNING SILICONE(Per Acurlite P.E. Analysis & Installation Manual)

SNAP ON COVER CAP(Not Required For Water Tightness)

C.H.M.

DRAWN BY:

K.A.M.CHECKED BY:

DATE - ISSUE:

SHEET:

SCALE:

STANDARDSYSTEMDETAILS

PLE

ASE

NO

TEA

LL D

ETA

ILS

AS

SHO

WN

ARE

FO

R RE

FERE

NC

EO

NLY

AN

D S

UBJE

CT

TO C

HAN

GE

PER

AC

URLI

TE P

ROJE

CT

PRO

POSA

L, S

PEC

IFIC

SITE

CO

ND

ITIO

NS,

AC

URLI

TE P

.E. A

NA

LYSI

S, A

ND

GO

VER

NIN

G C

OD

E RE

QUI

REM

ENTS

.

11/30/17 - A

© 570.

759.

6882

w

ww

.acu

rlit

e.co

m

sale

s@ac

urlit

e.co

m

NO

V 3

0, 2

017

D7

6" = 1' - 0"

Page 9: ALL DETAILS AS SHOWN ARE FOR REFERENCE ONLY AND … · 2020-02-13 · w/ gable end isometric view single pitch c.h.m. drawn by: k.a.m. checked by: date - issue: sheet: scale: standard

TYPICAL DETAILGABLE POST

D8

SILICONE GASKETEXTRUDED ALUM. PURLIN

(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)

EXTRUDED ALUM. RAFTER(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)

INSULATED LAMINATED / LAMINATED GLAZINGINCLUDES ALL BACKER ROD & GLAZING SEALANTS

(Max Unit Size & Required Thickness - Per AAMA Guidelines)(Glazing Calculations Can Be Provided For Additional Cost)

STANDARD & CUSTOM FINISHES(Paint, Anodize & Powder Coat Available)

OPTIONS FOR VISUAL ENHANCEMENT

SHADES/LOUVERS - PANELS - BIPV/DYNAMIC GLAZING(Consult Factory for your project specific needs)

VARIABLE SLOPE - ALL PITCHES AVAILABLE(Consult Factory - Based On Project Specific Conditions)

FORMED SILL PAN - 1/16" ALUM. STANDARD(Consult Factory For Optional Thickness & Materials)

EXTRUDED ALUM. COVER CAP& PRESSURE CAP W/ GASKET

SILL LUG(Lug Size, Type & Locations Per Acurlite P.E. Analysis)

USE SPECIFIED DOW CORNING SILICONE(Per Acurlite P.E. Analysis & Installation Manual)

FASTENERS PROVIDED BY ACURLITE(Fastener Size & Type Per Acurlite P.E. Analysis Unless Noted)

SNAP ON COVER CAP(Not Required For Water Tightness)

INSTALL GLAZING PER INDUSTRY STANDARDS(Follow GANA Guidelines & Acurlite Installation Manual)

FASTEN PRESSURE CAP TO RAFTER & APPLY SEAL

INSTALLATION

FASTEN PURLIN ASSEMBLY TO RAFTER

FULL BEARING SHIM - IF REQUIRED(1/4" Max. Shim Space Typical - Unless Noted Otherwise)(Not by Acurlite - Provided By Others)

FASTEN RAFTER ASSEMBLY TO LUGS - IF REQ.

FASTEN SILL LUG TO CURB(Seal In & Around Lug & Fastener)

INSTALL SILL PAN IN BED OF SEALANT

SILL CURB - INSIDE EDGE(Not Provided By Acurlite - Provided By Others)

C.H.M.

DRAWN BY:

K.A.M.CHECKED BY:

DATE - ISSUE:

SHEET:

SCALE:

STANDARDSYSTEMDETAILS

PLE

ASE

NO

TEA

LL D

ETA

ILS

AS

SHO

WN

ARE

FO

R RE

FERE

NC

EO

NLY

AN

D S

UBJE

CT

TO C

HAN

GE

PER

AC

URLI

TE P

ROJE

CT

PRO

POSA

L, S

PEC

IFIC

SITE

CO

ND

ITIO

NS,

AC

URLI

TE P

.E. A

NA

LYSI

S, A

ND

GO

VER

NIN

G C

OD

E RE

QUI

REM

ENTS

.

11/30/17 - A

© 570.

759.

6882

w

ww

.acu

rlit

e.co

m

sale

s@ac

urlit

e.co

m

NO

V 3

0, 2

017

D8

6" = 1' - 0"

Page 10: ALL DETAILS AS SHOWN ARE FOR REFERENCE ONLY AND … · 2020-02-13 · w/ gable end isometric view single pitch c.h.m. drawn by: k.a.m. checked by: date - issue: sheet: scale: standard

TYPICAL DETAILGABLE JAMB

D9

CURB / SUBSTRUCTURE BY OTHERS

ISOLATION/WATERPROOF MEMBRANE(Not By Acurlite - Provided By Others)

DETAILS / MATERIALS PER CONTRACT DOCUMENTS(Not By Acurlite - Provided By Others)

PROPER SUBSTRATE REQUIRED FOR ATTACHMENT(Not By Acurlite - Provided By Others)

COUNTER FLASHING & REGLETS(Not By Acurlite - Provided By Others)

SILICONE GASKETEXTRUDED ALUM. PURLIN

(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)

EXTRUDED ALUM. RAFTER(2 1/2" Width - Depth/Reinforcement Per Acurlite P.E. Analysis)

INSULATED LAMINATED / LAMINATED GLAZINGINCLUDES ALL BACKER ROD & GLAZING SEALANTS

(Max Unit Size & Required Thickness - Per AAMA Guidelines)(Glazing Calculations Can Be Provided For Additional Cost)

STANDARD & CUSTOM FINISHES(Paint, Anodize & Powder Coat Available)

OPTIONS FOR VISUAL ENHANCEMENT

SHADES/LOUVERS - PANELS - BIPV/DYNAMIC GLAZING(Consult Factory for your project specific needs)

VARIABLE SLOPE - ALL PITCHES AVAILABLE(Consult Factory - Based On Project Specific Conditions)

FORMED EXTERIOR CLOSURE - 1/16" ALUM. STANDARD(Consult Factory For Optional Thickness & Materials)(Typical Splice Shown As Dashed Line - Locate As Required)

FORMED ANGLE SPACER - 1/16" ALUM. STANDARD(Consult Factory For Optional Thickness & Materials)(Factory Applied To Rafter)

CURB SHOULD BE PLUMB, LEVEL & SQUAREPER INDUSTRY STANDARD TOLERANCES

(Max Allowed ±1/8" PER 12' - 0" - Unless Noted Otherwise)(Not By Acurlite - Provided By Others)

CURB MUST RESIST ALL LOADS/REACTIONSIMPOSED BY SKYLIGHT

(Reactions Provided By Acurlite P.E.)(Responsible E.O.R. to Verify and Approve)

PLEASE NOTE

ALL ROOFING, TERMINATION BARS, REGLETS,COUNTER FLASHINGS & FLASHINGS NOT

INTEGRAL TO SKYLIGHT SYSTEM FUNCTION(Not By Acurlite - Provided By Others)

FORMED END DAM - 1/16" ALUM. STANDARD(Consult Factory For Optional Thickness & Materials)

FORMED SILL PAN - 1/16" ALUM. STANDARD(Consult Factory For Optional Thickness & Materials)

EXTRUDED ALUM. COVER CAP& PRESSURE CAP W/ GASKET

USE SPECIFIED DOW CORNING SILICONE(Per Acurlite P.E. Analysis & Installation Manual)

FASTENERS PROVIDED BY ACURLITE(Fastener Size & Type Per Acurlite P.E. Analysis Unless Noted)

SNAP ON COVER CAP(Not Required For Water Tightness)

INSTALL GLAZING PER INDUSTRY STANDARDS(Follow GANA Guidelines & Acurlite Installation Manual)

FASTEN PRESSURE CAP TO RAFTER & APPLY SEAL

FASTEN EXTERIOR CLOSURE TO CURB(Shim & Seal As Required)

INSTALLATION

FASTEN EXTERIOR CLOSURE TO ANGLE SPACER(Not By Acurlite - Provided By Others)

FASTEN PURLIN ASSEMBLY TO RAFTER

BACKER ROD & CONTINUOUS SEALINSTALL END DAM & SILL PAN IN BED OF SEALANT

FULL BEARING SHIM - IF REQUIRED(1/4" Max. Shim Space Typical - Unless Noted Otherwise)(Not by Acurlite - Provided By Others)

FASTEN RAFTER ASSEMBLY TO LUGS - IF REQ.

FASTEN SILL LUG TO CURB(Seal In & Around Lug & Fastener)

SILL LUG(Lug Size, Type & Locations Per Acurlite P.E. Analysis)

SILL CURB - INSIDE EDGE(Not Provided By Acurlite - Provided By Others)

C.H.M.

DRAWN BY:

K.A.M.CHECKED BY:

DATE - ISSUE:

SHEET:

SCALE:

STANDARDSYSTEMDETAILS

PLE

ASE

NO

TEA

LL D

ETA

ILS

AS

SHO

WN

ARE

FO

R RE

FERE

NC

EO

NLY

AN

D S

UBJE

CT

TO C

HAN

GE

PER

AC

URLI

TE P

ROJE

CT

PRO

POSA

L, S

PEC

IFIC

SITE

CO

ND

ITIO

NS,

AC

URLI

TE P

.E. A

NA

LYSI

S, A

ND

GO

VER

NIN

G C

OD

E RE

QUI

REM

ENTS

.

11/30/17 - A

© 570.

759.

6882

w

ww

.acu

rlit

e.co

m

sale

s@ac

urlit

e.co

m

NO

V 3

0, 2

017

D9

6" = 1' - 0"