Upload
kosong-sudahan
View
219
Download
0
Embed Size (px)
Citation preview
8/13/2019 Analogue Multimeters
1/2
M X 2 B a n d M X 1
A n a lo g u e M u lt im e t e r s
T h e s e h ar d -w e a r in g in s t r u m e n t s a r e t h e 4 X 4 s
o f t h e m u lt im e t e r w o r ld !
Continuity test with audible beep signal
Protection on all ranges
S a fety alarms in
Casing design renowned for its toughness
200 A current-clamp comes as standard with the MX 2B
Carrying case version available
8/13/2019 Analogue Multimeters
2/2
Code
:90
6
111
780
-Ed.1
-12/99
DC VoltagesR a ng e s 0. 5 V - 1. 5 V - 5 V - 1 5 V - 50 V - 15 0 m V - 0. 5 V - 1. 5 V - 5 Vv - 1 5 V - 5 0 V -
150 V - 500 V - 1.5 kV 150 V - 500 V - 1.5 kVP ro tec tion 320 Vrms (ra ng e 5 V) - 500 Vrms (15 V ) - 320 Vrms (rang e 5 V) - 500 Vrms (15 V ) -
1000 Vrms (50 V) - 1500 Vrms (150 V to 1.5 kV) 1000 Vrms (50 V) - 1500 Vrms (150 V to 1.5 kV)Accura cy c la ss 2 2
Input Impeda nce 20 k /V 20 k /V AC Voltages
Ranges 5 V - 15 V - 50 V - 150 V - 500 V - 1,5 kV 5 V - 15 V - 50 V - 150 V - 500 V - 1,5 kVP ro te ctio n 320 Vrms (ra ng e 15 V) - 500 Vrms (50 V) - 320 Vrms (rang e 15 V) - 500 Vrms (50 V) -
1000 Vrms (150 V) - 1500 Vrms (500 V and 1.5 kV) 1000 Vrms (150 V) - 1500 Vrms (500 V and 1.5 kV)
Ba ndwid th 16 Hz to 1 kHz (500 Hz /1500 V) 16 Hz to 1 kHz (500 Hz /1500 V)Accura cy c la ss 2.5 2.5
Input Impeda nce 2 k/V 6.32 k/V DC currents
Ra ng es 50 A - 10 A 50 - 500 A - 5 - 150 - 500 mA - 1,5 - 10 AAccura cy c la ss 2 2
Line drop < 0.5 V 1.2 V ma xP rotec tion 1.6 A a nd 10 A fus es - 10 kA / 600 Vrms 1.6 A a nd 10 A fus es - 10 kA / 600 Vrms
AC currents
Ranges With AM 13N c la mp 500 A - 5 - 150 - 500 mA - 1,5 - 10 A10 A 20 A 100 A 200 AC la ss e de prcis ion 3 3 3 3 2.5
Chute de tension - 1.2 V ma xP rotection 1.6 A fus e - 10 kA /600 Vrms 1.6 A a nd 10 A fuses - 10 kA /600 Vrms
ResistancesRa ng es x 1 x 10 x 100 x 1 x 10 x 100
S ca le mid-point 200 2 k 20 k 200 2 k 20 kAccura cy c la ss 2.5 2.5
P ro te ctio n Ele ctro nic 400 Vrms (5s ) + a u dib le ala rm Ele ctro nic 400 Vrms (5s ) + a u dib le ala rm Continuity
Detection threshold R < 150 R < 150 Other measurements
Diode tes t Yes YesdB Yes Yes
TECHNICAL SPECIFICATION MX 2B MX 1
Wa ter-tightnes s IP 65
Length of sca le 80 mmS a fety IEC 61010-1, Ca t.III, 600 V - P ollution level 2
Opera ting Tempera ture -10 to 50 C
S upply 1.5 V ba ttery (AA, R6)
Dimens ions /w eight 40 x 98 x 150 mm /420 g
GENERAL SPECIFICATION
M X 2 B a n d M X 1 : T h e s e ha r d -w e a r in g in s t r u m e n t sa r e t h e 4 X 4 s o f t h e m u lt i m e t e r w o r ld !
A u d ib le c o n t in u it y t e s t
Using this continuity test with audible beepsignal connections can be checked when
ca rrying out resistanc e mea surement.
P r o t e c t i o n o n a ll r a n g e s
An input as high as 400 Vrms results in noda mage to the device, even when ca rrying outresistanc e mea surement. This o hmmeterfunction is protec ted by a n electronic c ircuitwhich, without a fuse, is both reliable andextreme ly quick to rea ct. The input terminalsca n take trans ient pulses up to 6 kV.As for the current ranges , they are protectedby high rupturing capacity (HRC) safety fusesa ga inst 600 V.
S a f e t y A l a r m s
In ohmmeter use an audible warning signallets the user know if an AC network voltage is
applied at the input.There is a lso a visible indicato r that lights up ifa fuse is blown.
A C c u r r en t m e a s ur e m e nt
The MX 2B c omes with a c urrent clamp fo rcurrent measurement that can be carried outsa fely up to 200 A. The AM 13N clamp ma kescurrent mea surement pos sible w ithout havingto break the c ircuit being mea sured.
R e n o w n e d r u g g e d c a s i n g d e s ig n
The professiona lly des igned ca sing is s plash-proof and, thanks to a shock-proof surround,
also resistant to knocks a nd drops. Its smoothcasing design also makes it easy to clean.
U n f a i l i n g s a f e t y
The MX 2B a nd the MX 1 are c omp letely dou-bly insulated devices, good for measurementup to 1500 V. Furthermore, the S ECURX ca se-locking system prevents a ccidental disconnec -ting of the measurement leads. It also preventsthe opening of the ca sing, to change the fusesor the battery, whilst the measurement leadsare still connected.
For a ss ista nce a nd orderingCharacteristics subject to modifications according to technological developments.
D i v i s i o n o f C h a u v i n A r n o u x
FRANCE
6, avenue du Pr de Challes - BP 330
74943 ANNECY-LE-VIEUX Ce de x
Tel. : 33 4 50 64 22 22 - Fax : 33 4 50 64 22 13
190, rue C hampionnet75876 PARIS Cedex 18
Tel. : 33 1 44 85 44 86 - Fax : 33 1 46 27 95 59
UNITED KINGDOM
CA UK Ltd - Metrix
Waldec k House - Waldec k Road
Maidenhead SL6 8BR
Tel. : (01628) 788 88 8