ANGLE MEASUREMENTS
Sine bar
Autocollimator
Electronic Level
Profile Projector
Laser Interferometer
CMM etc
Tool maker’s microscope
Angle Gauges Spirit level
Protractors
Clinometer
Beam comparator
Angle Gauges
Available in sets
1, 3, 9, 27, 41- degrees
1, 3, 9, 27 - minutes
3, 9, 27 or 6, 12, 18 – seconds
plus a square block 13 gauges in Set 1
1, 3, 5, 15, 30, 45 - degrees
1, 3, 5, 20, 30 - minutes
1, 3, 5, 20, 30 - seconds plus a square block 17 gauges in Set 2
Sine Bar
Specified using centre distance 100, 200, 400 mm etc. 4”, 5”,10” etc.
5” sine bar with error of
Centre distance 0.001mm
450 2.8”
600 4.0”
700 6.0”
Spirit level
To measure the angular divergencies
Simple and yet powerful
Sensitivity is defined as the
Displacement of bubble / Change in inclination in mm / sec
R = L / θ = 2. 5 mm / 10 secs
= 50 m app.
Sensitivity =Displacement Per scale division of bubble for a Change in
inclination ( mm / sec ) R = L / θ = 2. 5 mm / 10 secs = 50 m app.
θ
L
R
Optical diagram of a Micro optic Auto collimator
1 eyepiece
2,4 prisms
3 beamsplitter
5 crosswire
6 lamp
7,8 reflectors
9 objective
lens
10 plane of setting images
Minute’s scale knobSecond’s scale knob
1 optical flat
2 minute’s scale knob
3 Ocular
4 minute scale
5 Second’s scale
6 Cam
7 Pinion
8 Knob for tilting flat
9 Gear wheel
10 Pin
Measuring Ocular and its reticules
5 ”
4 ”
Straightness Evaluation – Autocollimator readings
Readings – 10 ’ 00 ’,10 ’10 ’’,9 ’55” ,10 ’15”,9 ’56”
Pitch distance – 100mm
10”
15”
5
108.0
10”
15”1.6
2.5
4.8
End points Zero Method
2.3
3.6
5.0
0
Straightness error = 3.6 +2.3µm
End Points Zero Line
Error = 6.25µm
Valley points method
Valley points line -1
Valley points line -2
2.53.75
5.0
5.0
10.0
7.5
Error = 5.0 µm
Two halves
Of the inductive
transducer
Centre zero meter
Pendulum Device
Incorporating armature
Knobs for Zero Adjustment